You are on page 1of 10

34-ST-16U-88

Issue 10
Page 1 of 10

Model STR800 Model Selection Guide


(DP, GP & AP) Remote Seals

Instructions
● Select the desired Key Number. The arrow to the right marks the selection available.
● Make selections from each Table (I, II and IX) using the column below the proper arrow.
● A (●) denotes unrestricted availability. A letter denotes restricted availability.
● Restrictions follow Table IX.

Key Number I II III IV V VI VII VIII IX


STR _ _ _ - _______ - _________ - _ - ___ - ___ - _ - ____ - __, + 0000
__

KEY NUMBER URL LRL Max Span Min Span Units Selection Availability
400 (1000) -400 (-1000) 400 (1000) 4 (10) " H2O (mbar) STR82D √
Measurement 100 (7) -100 (-7) 100 (7) 1 (0.07) psi (bar) STR83D √
Range Std 500 (35) 5.7 (0.39) 500 (35) 5 (0.35) psia (bar A) STR84A √
Accuracy 500 (35) -14.7 (-1.0) 500 (35) 5 (0.35) psi (bar) STR84G √
3000 (210) 14.7 (-1.0) 3000 (210) 30 (2.1) psi (bar) STR87G √
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.

TABLE I Description Selection


1 Remote Seal (High Side) 1______ ● ●
a. Number of
2 Remote Seals 2______ ●
Seals
1 Remote Seal (Low Side) 3______ ●
b. Primary Fill Silicone Oil 200 _1_____ ● ●
Fluid Fluorinated Oil CTFE _2_____ 2 2
c. Construction Non-Wetted Adapter Head Materials
In-Line Gauge/ 316 SS Bonnet __A____ ●
Absolute 316 SS Bonnet for Close-Couple __B____ 3
316 SS (bolt-on heads) __C____ ●
Dual Head DP 316 SS for Close-Couple __D____ 3
316 SS with all-welded meter body __E____ 4
None ___0___ 22 ●
d. Bolts and Nuts Carbon Steel Bolts and Nuts ___C___ ●
for Transmitter 316 SS Bolts and Nuts ___S___ ●
Heads A286 SS (NACE) Bolts and 304 SS (NACE) Nuts ___N___ ●
B7M (NACE) Bolts and 7M (NACE) Nuts ___B___ ●
No Fill Fluid ____0__ 5 5
Silicone Oil 200 ____1__ ● ●
e. Secondary Fill
Meter Body & Fluorinated Oil CTFE ____2__ ● ●
Fluid (capillary &
Capillaries Silicone Oil 704 ____3__ ● ●
seal) ● ●
Neobee® M20 11 ____4__
®
Syltherm 800
12
____5__ ● ●
No Capillary, No Nipple (Specify for VAM Unit Only) _____0_ 5 5
5 feet 1.5 m _____A_ ● ●
10 feet 3.0 m _____B_ ● ●
15 feet 4.5 m _____C_ ● ●
SS Armor
20 feet 6.1 m _____D_ ● ●
f. Connection of 25 feet 7.5 m _____E_ ● ●
Capillary 35 feet 10.7 m _____F_ ● ●
Remote Seal to
Length 5 feet 1.5 m _____G_ ● ●
Meter Body 10 feet 3.0 m _____H_ ● ●
15 feet 4.5 m PVC Coated SS _____J_ ● ●
20 feet 6.1 m Armor _____K_ ● ●
25 feet 7.5 m _____L_ ● ●
35 feet 10.7 m _____M_ ● ●
2 inch long SS nipple close-coupled _____2_ 6 6
None ______0 ● ●
g. Seal Option Std Gold Plated Seal Diaph. = 50 µin ______1 7 7
Teflon Coated Seal Diaphragm - only for anti-sticking ______4 7 7

Indicates options with best standard delivery √


11
Limited vacuum availability.
12
Minimum static pressure requirement. No vacuum allowed. See Specifications 34-ST-03-88 Figure 15

In-Line Gauge Dual Head DP All welded


34-ST-16U-88
Issue 10
Page 2 of 10

STR84G & 87G & 84A


STR82D & 83D

Note: When selecting required seal, you must specify


Selection
only the 9 selections within the required seal type.

TABLE II Description
No Seal Attached to Core Transmitter (Specify for VAM Unit Only) 000000000 21 21
Diaphragm Flange Flange Pressure
Seal Type Selection
Diameter Size Rating 1
ANSI Class 150 AFA _ _ _ _ _ _ ● ●
3"
3.5" ANSI Class 300 AFC _ _ _ _ _ _ ● ●
80mm DIN DN80-PN40 AFM _ _ _ _ _ _ ● ●
Diaphragm Upper Insert Selection
316L SS 316L SS _ _ _ AA _ _ _ _ ● ●
Hastelloy® C-276 316L SS _ _ _ AB _ _ _ _ ● ●
Wetted Material
Hastelloy® C-276 Hastelloy® C-276 _ _ _ AC _ _ _ _ ● ●
® ®
Monel 400 Monel 400 _ _ _ AE _ _ _ _ 8 8
5
Tantalum 316L SS _ _ _ AF _ _ _ _ 8 8
Non-Wetted Material CS (Nickel Plated) _____1___ ● ●
(upper) 316L SS _____2___ ● ●
Seals Seal-Capillary Center Seal ______1__ ● ●
Connection Side Seal ______2__ 9 9
Flush Flanged Seal Calibration Rings None _______A_ ● ●
316L SS _______B_ 10 10
®
Hastelloy C-276 _______C_ 10 10
Monel 400® _______D_ 10 10
Flushing None ________0 ● ●
Connections One 1/4" with plastic plug ________H 11 11
4
and Plugs One 1/4" with metal plug ________J 11 11
(Metal plug material Two 1/4" with plastic plugs ________M 11 11
will be the same as Two 1/4" with metal plugs ________N 11 11
Cal. ring material if One 1/2" with plastic plug ________P 11 11
metal plug is chosen ) One 1/2" with metal plug ________Q 11 11
Two 1/2" with plastic plugs ________R 11 11
Two 1/2" with metal plugs ________S 11 11
Table II continued next page

1
Standard facing 125-250 AARH RF (raised face) serrated surface finish.
4
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation
5
Tantalum Upper insert has Tantalum wetted parts and 316 SS or CS non-wetted parts

Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
34-ST-16U-88
Issue 10
Page 3 of 10

STR84G & 87G & 84A


STR82D & 83D

TABLE II Descripton Selection


Diaphragm Flange Flange Pressure Const. - See Spec. Construction - See Spec.
Seal Type
Diameter Size Rating 1 Figure 34-ST-03-88 Figure 34-ST-03-88

ANSI 150 22 BCA _ _ _ _ _ _ 12 ●


1"
ANSI 300 22 BCC _ _ _ _ _ _ 12 ●
ANSI 150 22 BGA _ _ _ _ _ _ 12 ●
1-1/2"
ANSI 300 22 BGC _ _ _ _ _ _ 12 ●
2.4"
ANSI 150 22 BDA _ _ _ _ _ _ 12 ●
2"
ANSI 300 22 BDC _ _ _ _ _ _ 12 ●
ANSI 150 22 BFA _ _ _ _ _ _ 12 ●
3"
ANSI 300 22 BFC _ _ _ _ _ _ 12 ●
1/2" ANSI 150 23 CAA _ _ _ _ _ _ ● ●
ANSI 150 23 CCA _ _ _ _ _ _ ● ●
1"
ANSI 300 23 CCC _ _ _ _ _ _ ● ●
2.9" ANSI 150 22 CGA _ _ _ _ _ _ ● ●
1-1/2"
ANSI 300 22 CGC _ _ _ _ _ _ ● ●
ANSI 150 22 CDA _ _ _ _ _ _ ● ●
2"
ANSI 300 22 CDC _ _ _ _ _ _ ● ●
1/2" ANSI 150 22 DAA _ _ _ _ _ _ ● ●
ANSI 150 23 DCA _ _ _ _ _ _ ● ●
1"
ANSI 300 23 DCC _ _ _ _ _ _ ● ●
ANSI 150 23 DGA _ _ _ _ _ _ ● ●
1-1/2"
4.1" ANSI 300 23 DGC _ _ _ _ _ _ ● ●
ANSI 150 23 DDA _ _ _ _ _ _ ● ●
2"
ANSI 300 22 DDC _ _ _ _ _ _ ● ●
ANSI 150 22 DFA _ _ _ _ _ _ ● ●
Seals (continued) 3"
Flush Flanged ANSI 300 22 DFC _ _ _ _ _ _ ● ●
Seal Diaphragm Lower Selection
with Lower 316L SS 316L SS _ _ _ BA _ _ _ _ ● ●
®
Hastelloy C-276 316L SS _ _ _ BB _ _ _ _ ● ●
Hastelloy® C-276 Hastelloy® C-276 _ _ _ BC _ _ _ _ ● ●
Wetted Material ®
Monel 400 Monel 400® _ _ _ BE _ _ _ _ 8 8
Tantalum 316L SS _ _ _ BF _ _ _ _ 8 8
Tantalum Hastelloy® C-276 _ _ _ BG _ _ _ _ 8 8
Tantalum Tantalum Clad _ _ _ BH _ _ _ _ 13 13
Upper Upper Insert Selection
Non-Wetted Material
316L SS 316L SS _____4___ ● ●
(upper, upper insert)
Carbon Steel 316L SS _____5___ ● ●
Bolts 6 No Selection ______0__ ● ●
Flushing None _______0 _ ● ●
Connections One 1/4" with plastic plug _______H_ ● ●
and Plugs
4 One 1/4" with metal plug _______J _ ● ●
(Metal plug material Two 1/4" with plastic plugs _______M_ ● ●
will be the same as Two 1/4" with metal plugs _______N_ ● ●
Lower material, if One 1/2" with plastic plug _______P_ ● ●
metal plug is chosen - One 1/2" with metal plug _______Q_ ● ●
(SS Plug for CS Lower Two 1/2" with plastic plugs _______R_ ● ●
and Tantalum Clad) Two 1/2" with metal plugs _______S_ ● ●
Klinger® C-4401 ________K ● ●
(non-asbestos)
Gasket Grafoil
® ________G ● ●
Teflon
® ________T ● ●
®
Gylon 3510 ________L 15 15
Table II continued next page

1
Standard facing 125-250 AARH RF (raised face) serrated surface finish.
6
Bolt material will be same as Upper Material. However, if Table I bolts/nuts material is NACE or B7M, seal bolt material will be 304 SS NACE.
4
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation

Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
34-ST-16U-88
Issue 10
Page 4 of 10

STR84G & 87G & 84A


STR82D & 83D
TABLE II Descripton
Diaphragm Flange 1
Seal Type Flange Pressure Rating Selection
Diameter Size
3" ANSI Class 150 EFA _ _ _ _ _ _ ● ●
2.8" (2.8" OD ANSI Class 300 EFC _ _ _ _ _ _ ● ●
extension) DIN DN80-PN40 EFM _ _ _ _ _ _ ● ●
4" ANSI Class 150 FGA _ _ _ _ _ _ ● ●
3.5" (3.70" OD ANSI Class 300 FGC _ _ _ _ _ _ ● ●
extension DIN DN100-PN40 FGP _ _ _ _ _ _ ● ●
Diaphragm Ext. Tube Selection
Flange Seal
Seals (continued) 316L SS 316L SS _ _ _ EA _ _ _ _ ● ●
with Extended Wetted Material
Hastelloy® C-276 316L SS _ _ _ EB _ _ _ _ ● ●
Diaphragm
Hastelloy® C-276 Hastelloy® C-276 _ _ _ EC _ _ _ _ ● ●
Non-Wetted CS (Nickel Plated) _____7___ ● ●
Material (flange) 316L SS _____8___ ● ●
Bolts No Selection ______0__ ● ●
2" _______2 _ ● ●
Extension Length 4" _______4_ ● ●
6" _______6_ ● ●
No Selection No Selection No Selection ________0 ● ●
Table II continued below

STR84G & 87G & 84A


STR82D & 83D
TABLE II Descripton

Diaphragm Flange Flange Pressure Rating Dependent


Seal Type Selection
Diameter Size on Customer Flange 1

3.5" 3" ANSI Class 150/300/600 GFA _ _ _ _ _ _ ● ●


Diaphragm Body
316L SS 316L SS _ _ _ GA _ _ _ _ ● ●
Hastelloy® C-276 316L SS _ _ _ GB _ _ _ _ ● ●
Wetted Material
Hastelloy® C-276 Hastelloy® C-276 _ _ _ GC _ _ _ _ ● ●
®
Monel 400 Monel 400® _ _ _ GE _ _ _ _ 8 8
7
Tantalum Tantalum _ _ _ GG _ _ _ _ 8 8
Non-Wetted Material No Selection _____0___ ● ●
Bolts No Selection ______0__ ● ●
Seals (continued) Calibration Rings None _______A_ ● ●
316L SS _______B_ 10 10
Pancake Seal Hastelloy® C-276 _______C_ 10 10
Monel 400® _______D_ 10 10
Flushing None ________0 ● ●
Connections One 1/4" with plastic plug ________H 11 11
and Plugs4 One 1/4" with metal plug ________J 11 11
(Metal plug material Two 1/4" with plastic plugs ________M 11 11
will be the same as Two 1/4" with metal plugs ________N 11 11
Cal. Ring material, if One 1/2" with plastic plug ________P 11 11
metal plug is chosen) One 1/2" with metal plug ________Q 11 11
Two 1/2" with plastic plugs ________R 11 11
Two 1/2" with metal plugs ________S 11 11
Table II continued next page

1
Standard facing 125-250 AARH RF (raised face) serrated surface finish.
4
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation
7
Tantalum Body has Tantalum wetted parts and 316 SS non-wetted parts

Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
34-ST-16U-88
Issue 10
Page 5 of 10

STR84G & 87G & 84A


STR82D & 83D
TABLE II Descripton
Diaphragm Flange 1
Seal Type Flange Pressure Rating Selection
Diameter Size
Taylor
3.5" Wedge 750 psi HM0 _ _ _ _ _ _ 16
5" O.D.
Diaphragm Body Selection
Seals (continued) 316L SS 316L SS _ _ _ HA _ _ _ _ ●
Wetted Material
Hastelloy® C-276 316L SS _ _ _ HB _ _ _ _ ●
Chemical Tee
Hastelloy® C-276 Hastelloy® C-276 _ _ _ HC _ _ _ _ ●
"Taylor" Wedge
Non-Wetted Material No Selection _____0___ ●
Bolts No Selection _____0__ ●
Styles No Selection _______0 _ ●
No Selection No Selection ________0 ●
Table II continued below

STR84G & 87G & 84A


TABLE II Descripton STR82D &83D
Threaded Process Pressure Rating
Diaphragm
Seal Type Connection Size 304 SS
Diameter CS Bolts Selection
(NPT Female) Bolts
1/2 NPT JJG _ _ _ _ _ _ 12 ●
2,500 1,250
2.4" 3/4 NPT JKG _ _ _ _ _ _ 12 ●
psi psi
1 NPT JLG _ _ _ _ _ _ 12 ●
1/2 NPT KJG _ _ _ _ _ _ ● ●
2,500 1,250
2.9" 3/4 NPT KKG _ _ _ _ _ _ ● ●
psi psi
1 NPT KLG _ _ _ _ _ _ ● ●
1/2 NPT LJG _ _ _ _ _ _ ● ●
1,500 750
4.1" 3/4 NPT LKG _ _ _ _ _ _ ● ●
psi psi
1 NPT LLG _ _ _ _ _ _ ● ●
Diaphragm Lower Selection
316L SS Carbon Steel _ _ _ JA _ _ _ _ ● ●
316L SS 316L SS _ _ _ JB _ _ _ _ ● ●
Hastelloy® C-276 316L SS _ _ _ JC _ _ _ _ ● ●
Wetted Material
Hastelloy® C-276 Hastelloy® C-276 _ _ _ JD _ _ _ _ ● ●
®
Monel 400 Monel 400® _ _ _ JE _ _ _ _ 8 8
Tantalum 316L SS _ _ _ JF _ _ _ _ 8 8
Seals (continued)
Seal with Threaded Tantalum Hastelloy® C-276 _ _ _ JG _ _ _ _ 8 8
Process Non-Wetted Material CS (Nickel Plated) _____A___ ● ●
Connection (upper) 316 Stainless Steel _____C___ 17 17
8 Carbon Steel ______C__ ● ●
Bolts
304 SS ______D__ ● ●
Flushing None _______0 _ ● ●
Connections One 1/4" with plastic plug _______H_ ● ●
and Plugs
4 One 1/4" with metal plug _______J _ ● ●
(Metal plug material Two 1/4" with plastic plugs _______M_ ● ●
will be the same as Two 1/4" with metal plugs _______N_ ● ●
Lower material, if One 1/2" with plastic plug _______P_ 18 18
metal plug is chosen - One 1/2" with metal plug _______Q_ 18 18
(SS Plug for CS Lower Two 1/2" with plastic plugs _______R_ 18 18
and Tantalum Clad) Two 1/2" with metal plugs _______S_ 18 18
Klinger® C-4401 ________K ● ●
(non-asbestos)
Gasket Grafoil® ________G ● ●
Teflon® ________T ● ●
®
Gylon 3510 ________L 15 15
Table II continued next page

1
Standard facing 125-250 AARH RF (raised face) serrated surface finish.
4
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation
8
If Table I Bolts and Nuts material option is NACE, Bolts and Nuts will ship with Alloy Steel NACE and MAWP may change.

Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
34-ST-16U-88
Issue 10
Page 6 of 10

STR84G & 87G & 84A


STR82D & 83D
TABLE II Descripton
Diaphragm Flange
Seal Type Pressure Rating Selection
Diameter Size
1.9" 2" MD0 _ _ _ _ _ _ 19
2.4" 2-1/2" Customer clamp rating or NE0 _ _ _ _ _ _ 20 19
2.9" 3" 600 psi, whichever is less PF0 _ _ _ _ _ _ 19 19
4.1" 4" QG0 _ _ _ _ _ _ 19 19
Seals (continued) Diaphragm Body Selection
Wetted Material
316L SS 316L SS ___NA____ ● ●
Sanitary Seal 9
Non-Wetted Material No Selection _____0___ ● ●

Bolts No Selection ______0__ ● ●


Styles Tri-Clover Tri-Clamp
®
_______8 _ ● ●
Gasket No Selection ________0 ● ●
Table II continued below

STR84G & 87G & 84A


TABLE II Descripton STR82D & 83D
Size and Seal Pressure Rating
Diaphragm
Seal Type Bolt
Diameter C.S. Bolts 316 SS Bolts Selection
Pattern
2.4" RFK _ _ _ _ _ _ 12 ●
for 3" Pipe
8-Bolt 2,500 psi 1,250 psi
≥ 4" pipe RGK _ _ _ _ _ _ 12 ●
Design
2.4" RPK _ _ _ _ _ _ 12 ●
for 3" Pipe
6-Bolt 2,000 psi 1,000 psi
≥ 4" pipe RQK _ _ _ _ _ _ 12 ●
Design
Diaphragm Lower Housing Selection
316L SS Carbon Steel _ _ _ RA _ _ _ _ ● ●
316L SS 316L SS _ _ _ RB _ _ _ _ ● ●
Wetted Material Hastelloy® C-276 316L SS _ _ _ RC _ _ _ _ ● ●
Seals (continued) Hastelloy® C-276 Hastelloy® C-276 _ _ _ RD _ _ _ _ ● ●
Saddle Seal 316L SS N/A-Body Only 10 _ _ _ SB _ _ _ _ ● ●
®
Hastelloy C-276 N/A-Body Only 10 _ _ _ SC _ _ _ _ ● ●
Body Bolts 10,11 Selection
Non-Wetted Material Carbon Steel Carbon Steel _____B___ 8 8
316L SS 316 SS _____C___ ● ●
Bolts No Selection ______0__ ● ●
Styles No Selection _______0_ ● ●
Klinger® C-4401 ________K ● ●
(non-asbestos)
Gasket Grafoil® ________G ● ●
Teflon® ________T ● ●
Gylon® 3510 ________L ● ●

9
All sanitary seals have dairy grade 3A approval.
10
Bolts are not included with "body only" selection.
11
If Table I Bolts and Nuts material option is NACE, seal bolt material will be 304 SS NACE.

Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
34-ST-16U-88
Issue 10
Page 7 of 10

STR84G & 87G & 84A


STR82D & 83D

TABLE III Agency Approvals (see data sheet for Approval Code Details)
No Approvals Required 0 ● ● √
FM Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof A ● ● √
CSA Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof B ● ● √
ATEX Explosion proof, Intrinsically Safe & Non-incendive C ● ● √
Approvals
IECEx Explosion proof, Intrinsically Safe & Non-incendive D ● ● √
SAEx/CCoE Explosion proof, Intrinsically Safe & Non-incendive E ● ● √
INMETRO Explosion proof, Intrinsically Safe & Non-incendive F ● ● √
NEPSI Explosion proof, Intrinsically Safe & Non-incendive G ● ● √

TABLE IV TRANSMITTER ELECTRONIC SELECTIONS


Material Connection Lightning Protection
Polyester Powder Coated Aluminum 1/2 NPT None A__ ● ● √
Polyester Powder Coated Aluminum M20 None B__ ● ● √
a. Electronic
Polyester Powder Coated Aluminum 1/2 NPT Yes C__ ● ● √
Housing Material
& Connection
Polyester Powder Coated Aluminum M20 Yes D__ ● ● √
Type
316 Stainless Steel (Grade CF8M) 1/2 NPT None E__ ● ●
316 Stainless Steel (Grade CF8M) M20 None F__ ● ●
316 Stainless Steel (Grade CF8M) 1/2 NPT Yes G__ ● ●
316 Stainless Steel (Grade CF8M) M20 Yes H__ ● ●
Analog Output Digital Protocol
b. Output/ 4-20mA dc HART Protocol _H_ ● ● √
Protocol 4-20mA dc DE Protocol _D_ ● ● √
none
Ext Zero, Span & Config Foundation Fieldbus _F_ ● ●
Indicator Buttons Languages
None None None __0 ● ● √
None Yes (Zero/Span Only) None __A f f √
c. Customer Basic None English __B ● ● √
Interface Basic Yes English __C ● ● √
Selections Advanced None EN,GR,IT, FR,SP,RU, TU __D ● ● √
Advanced Yes EN,GR,IT, FR,SP,RU, TU __E ● ● √
Advanced None EN, CH, JP __H ● ●
Advanced Yes EN, CH, JP __J ● ●

TABLE V CONFIGURATION SELECTIONS


a. Application Diagnostics
Software Standard Diagnostics 1__ ● ● √
3
Write Protect Fail Mode High & Low Output Limits
Disabled High> 21.0mAdc Honeywell Std (3.8 - 20.8 mAdc) _1_ f f √
b. Output Limit, Disabled Low< 3.6mAdc Honeywell Std (3.8 - 20.8 mAdc) _2_ f f √
Failsafe & Write Enabled High> 21.0mAdc Honeywell Std (3.8 - 20.8 mAdc) _3_ f f √
Protect Settings Enabled Low< 3.6mAdc Honeywell Std (3.8 - 20.8 mAdc) _4_ f f √
Enabled N/A N/A Fieldbus or Profibus _5_ g g √
Disabled N/A N/A Fieldbus or Profibus _6_ g g √
c. General Factory Standard __S ● ● √
Configuration Custom Configuration (Unit Data Required from customer) __C ● ●

TABLE VI CALIBRATION & ACCURACY SELECTIONS


Accuracy Calibrated Range Calibration Qty
Accuracy and
Calibration
NA None None 0 21 21 √
Standard Factory Std Single Calibration A ● ● √
Standard Custom (Unit Data Required) Single Calibration B ● ● √
3
NAMUR Output Limits 3.8 - 20.5mAdc can be configured by the customer or select custom configuration Table Vc
34-ST-16U-88
Issue 10
Page 8 of 10

STR84G & 87G & 84A


STR82D & 83D

TABLE VII ACCESSORY SELECTIONS


Bracket Type Material
None None 0___ ● ● √
Angle Bracket Carbon Steel 1___ ● ● √
a. Mounting
Angle Bracket 304 SS 2___ ● ● √
Angle Bracket 316 SS 3___ ● ●
Bracket
Marine Approved Angle Bracket 304 SS 4___ y ● √
Flat Bracket Carbon Steel 5___ ● ● √
Flat Bracket 304 SS 6___ ● ● √
Flat Bracket 316 SS 7___ ● ●
Customer Tag Type
b. Customer No customer tag _0__ ● ● √
Tag One Wired Stainless Steel Tag (Up to 4 lines 26 char/line) _1__ ● ● √
Two Wired Stainless Steel Tag (Up to 4 lines 26 char/line) _2__ ● ● √
Unassembled Conduit Plugs & Adapters

c. Unassembled No Conduit Plugs or Adapters Required _ _ A0 ● ● √


Conduit 1/2 NPT Male to 3/4 NPT Female 316 SS Certified Conduit Adapter _ _ A2 n n √
Plugs & 1/2 NPT 316 SS Certified Conduit Plug _ _ A6 n n √
Adapters M20 316 SS Certified Conduit Plug _ _ A7 m m √
®
Minifast 4 pin (1/2 NPT) _ _ A8 n n
®
Minifast 4 pin (M20) _ _ A9 m m

TABLE VIII OTHER Certifications & Options : (String in sequence comma delimited (XX, XX, XX,….)
None - No additional options 00 * *
NACE MR0175; MR0103; ISO15156 (FC33338) Process wetted parts only FG * *
b √
NACE MR0175; MR0103; ISO15156 (FC33339) wetted and non-wetted parts F7 c c √
Marine (DNV, ABS, BV, KR, LR) (FC33340) MT d d √
EN10204 Type 3.1 Material Traceability (FC33341) FX ● ● √
Certificate of Conformance (F3391) F3 ● ● √
b
Calibration Test Report & Certificate of Conformance (F3399) F1 ● ● √
Certifications & Certificate of Origin (F0195) F5 ● ● √
Warranty FMEDA (SIL 2/3) Certification (FC33337) FE j j √
Over-Pressure Leak Test Certificate (1.5X MAWP) (F3392) TP ● ●
Cert Clean for O2 or CL2 service per ASTM G93 OX e e
Extended Warranty Additional 1 year 01 ● ● √
Extended Warranty Additional 2 years 02 ● ● √
Extended Warranty Additional 3 years 03 ● ● b √
Extended Warranty Additional 4 years 04 ● ● √
Extended Warranty "LifeTime" Additional 15 years 15 ● ● √

TABLE IX Manufacturing Specials


Factory Factory Identification 0000 ● ●
34-ST-16U-88
Issue 10
Page 9 of 10

MODEL RESTRICTIONS
Restriction Available Only With Not Available With
Letter Table Selection(s) Table Selection(s)
b Select only one option from this group
d VIIa 1,2,3,5,6,7 _ _ _
c Id _ _ _ 0, N, B _ _ _

e Ib _2__2__
f IVb _F_
g IVb _ H, D _
j IVb _H_ Vb _ 1,2,6 _
m IVa B, D, F, H _ _
n IVa A, C, E, G _ _
y Ic __E____
____0__
2 Ie ____2__
____4__
Ia 2______
3 If _____2_

4 I 2__0___
VI 0
5
VIII FG, F7, FX, OX,TP,MT,F1
6 I _ _ B,D _ _ _ _ Ia 2______
_ _ _ AF _ _ _ _
_ _ _ BF _ _ _ _
_ _ _ BG _ _ _ _
7 II _ _ _ BH _ _ _ _
_ _ _ GG _ _ _ _
_ _ _ JF _ _ _ _
_ _ _ JG _ _ _ _
8 VIII FG, F7
_ _ _ AA2_ _ _
9 II
_ _ _ AB2_ _ _
10 II ________0
11 II _______A_
If _ _ _ _ _ A, G, 2 _
12

II ________T
13 II _______0_
VIII FG, F7
_ _ _ BF _ _ _ _
_ _ _ BG _ _ _ _
15 II _ _ _ BH _ _ _ _
_ _ _ JF _ _ _ _
_ _ _ JG _ _ _ _
16 I 2______
17 II _ _ _ JA _ _ _ _
JJG _ _ _ _ _ _
18 II JKG _ _ _ _ _ _
JLG _ _ _ _ _ _

19
If _____2_
If _ _ _ _ _ A, G _
20

21 I _ _ _ _ 000
22 Ic __E____

FM ApprovalsSM is a service mark of FM Global


Hastelloy® is a registered trademark of Haynes International
Monel 400® is a registered trademark of Special Metals Corporation.
HART® is a registered trademark of HART Communication Foundation.
FOUNDATIONTM Fieldbus is a registered trademark of Fieldbus Foundation.
Teflon® is a registered trademark of DuPont.
Neobee® is a registered trademark of Stepan Company.
Syltherm® 800 is a Trademark of Dow Corning Corporation
Klinger® C-4401 is a registered trademark of THERMOSEAL, INC
GRAFOIL® is a registered trademarks of GrafTech International Holdings Inc
Gylon® 3510 is registered trademark of Garlock Sealing Technologies
Tri-Clover Tri-Clamp® is a registered trademark of Alfa-Laval
DC® 200 and DC® 704 are registered trademarks of Dow Corning
34-ST-16U-88
Issue 10
Page 10 of 10

FIELD INSTALLABLE REPLACEMENT PARTS


Description Kit Number
Integrally Mounted Basic Indicator Kit (Compatible with all Electronic Modules) 50049911-501
Integrally Mounted Advanced Indicator Kit (Compatible with all Electronic Modules) 50049846-501
Terminal Strip w/Lightning Protection Kit for HART or DE Modules 50075472-532
Terminal Strip w/Lightning Protection Kit for FFB Module 50075472-534
Terminal Strip w/o Lightning Protection for HART or DE Modules 50075472-531
Terminal Strip w/o Lightning Protection FFB Module 50075472-533
HART Electronics Module 50049849-501
HART Electronics Module w/connection for external configuration buttons 50049849-502
DE Electronics Module 50049849-503
DE Electronics Module w/connection for external configuration buttons 50049849-504
FFB Electronics Module Kit 50049849-507
FFB Electronics Module w/connection for external configuration buttons 50049849-508

PAPER MANUALS
Description Part Number
Paper Manual ST 800 Smart Transmitter User Manual - English 34-ST-25-35
Paper Manual ST 800 Smart Transmitter HART/DE Communications Manual - English 34-ST-25-38
Paper Manual ST 800 Smart Transmitter Safety Manual - English 34-ST-25-37
Paper Manual ST 800 Smart Transmitter Foundation Fieldbus Manual - English 34-ST-25-39
Paper Manual ST 800 Smart Transmitter Function Block Manual - English 34-ST-25-42

You might also like