You are on page 1of 5

Error code

Model : Digi Dolphin Dlx, 7.0kg- FATL

NO ERROR ITEM ANALYSIS


1 EA Abnormal condition of The frequency of water lever sensor is
water level sensor above 73.728 kHz
Or below 8.192 kHz
2 E1 Abnormal condition of It doesn’t reach water level 1 after 10
water inlet minutes water inlet or doesn’t reach the
setting level after 20 minutes
3 E2 Abnormal condition of After 8 min drainage, it doesn’t reach
drain the reset water level.
4 E3 Abnormal condition of spin After 3 times of adjustment, the
tub still off-center or in a single
spin wash program, the tub
off-centered once.
5 E4 Uncover alarm Open the lid during electrolysis or spin
program or.
6 E5 Child lock alarm Open the lid for more than 5 min after
setting the child lock.
7 Eb Electrolytic tank alarm 1 Electrolysis strong current or electrolytic
piece short circuit.
8 Ed Electrolytic tank alarm 2 The feedback current is less than 0.3A
after continuous electrolysis for 1
minute.
9 Eu Power supply relay Power relay doesn’t shutoff after 60
seconds.
10 E901 Strong current The input current is too strong to the
motor rotation during the inverter
working program.
11 E902 High power voltage 275 AC continue 1.1S
12 E904 Low power voltage 75AC continue 1.1s
13 E908 Motor doesn’t turn. The motor doesn’t turn when it should
be, such as IPM fault.
14 E910 The abnormal condition of The current circuit detection on the
current circuit detection inverter is abnormal; either value
appears when no current output or no
value change when output.
15 E920 Abnormal condition of IPM IPM is abnormal, IGBT is broken, Fault
signals of IPM appear, or there is short
circuit of the motor wire
16 E940 Abnormal of Hall IC It gives wrong hall signals, HHH(5V)or
LLL(0V)
Error code
Model : Digi Dolphin Dlx, 7.0kg- FATL
No water inlet Are you turn on the tap? NO Turn it on
E1
YES
YES
Turn it on
YES Whether the mouth is blocked?
Whether the drain
Close the lid. NO
valve mouth vibrates
during the inlet YES
Clean it up
Are the wires are OK?

NO

Whether the voltage between the blue and orange wire is


0V in the three red core terminals
YES
In the PCB when the inlet valve is working? When it is not
Change the inlet valve
working, whether there is AC220V between them?

NO

Change the PCB

Whether the child lock is YES


Not wash E5 Close the lid.
on? Lid is open?

NO

Whether the PCB plug is plucked out?


Whether the connect wires are OK?

NO

Change the PCB Fix it well.


Error code
Model : Digi Dolphin Dlx, 7.0kg- FATL
七、Fault Judgment
Clothes are off-centered
No Spin during spin program. Turn You can try to do these::a.

spin tub back and forth. Adjust the machine level b.


E3 E4
Repeat it 4 times, E3 appears Add more clothes c. Turn off the

if it still off-centered and then machine and trim the clothes.

machine stops working; E4


shows when wash lid closed
during spin program. YES
No drain E2 Whether the drainage is blocked
Clean them up
in the user’s house? Whether
the bend is jammed?

NO
Whether the pipe is
Whether the drain pipe is OK? blocked?

YES YES
NO
Whether the three
Clean them up
white power supply
core in the PCB is fall YES
Fix it well.
off?(for the drain valve)

NO

Whether the drain valve Clean the drain


is turn off during the spin valve.
and drain program?

NO Change the
drain valve.
During the torque working time,
whether there is AC220V between YES
Change the
the blue and peach line in the three
torque motor
white terminals

NO
Change the PCB.
Error code
Model : Digi Dolphin Dlx, 7.0kg- FATL

Continue water inlet or drainage.

Pause, OK? Change the inlet valve.


NO

YES

Whether there is leakage in the Whether the switch Whether the three white core
drain pipe during inlet? of the torque motor terminals are off?
YES NO
is OK?

NO YES
YES NO
Whether there is Fix the terminals
leakage in the drain Whether the drain valve is blocked?
pipe during inlet?
NO YES Whether there is AC220V between
the white-purple wire in the three
Change the Clean the valve white terminals when the drain
NO motor valve is working? Whether there is
AC220V between the white-brown
wires when it is not working.
Whether the air trip hose is
bended or blocked? Clean it up NO
YES
Change the
NO YES
PCB.

Change the PCB.


Change the torque
motor.

Whether the PCB plug is not YES


EU Cut off the power Fix it well.
right? Whether the wire
supply.
connection is abnormal?

NO

Whether the power transformer is


broken?
YES
NO
Change the PCB. Change the transformer.
Error code
Model : Digi Dolphin Dlx, 7.0kg- FATL
E9 Motor is not working.

Whether the PCB plug is not


YES
right? Whether the wire
Fix it.
E901 connection is abnormal?

YES NO

Whether there is too much


bubbles in the spin tub? Change the PCB.
NO
YES

E9-08,40 Change the motor if not working.


Clean the bubbles.

Eb, Ed Whether the PCB plug YES


is not right? Whether Fix it.
the wire connection is
abnormal?
NO

Check whether there is YES


short circuit in the Change the Electrolytic tank.
Electrolytic tank

NO

Change the PCB.

You might also like