Schlumberger Rig IDC 37 Well: | R-555 Toate: | 21-oct-2013 | Timo: | 10:00 Rig Manager LX ROO representative [J IPMNWSS LX Geoservices - Log @ Driller Ld Geologist. Od WSSibCementing Qo ‘MI Engineer tesco [ey Objective: BOP pressure test. DRILLING OPERATION: 1. Function test top rams, blind rams, kill line and chok ine HCR's from different remote operated panels. 2, M/U wear bushing running tool, RIH and engage ito wear bushing, 3. Retract lower 2 ea (180 deg opposite) tie- down screws on 13-5/8" MBS Upper spool. Retrieve wear bushing under Cameron supervision, 4. M/Utest assy as follo ‘stand of 5” HWDP + test plug + 1 jt of 5 DP + SES + FOSV + Grey valve (IBOP) + 5° Pup Joint (test plug hand tide) and set test plug into well head (8.9 m from rig floor). 5. Connect TDS. 6. Make sure to remove plug from test plug. Remove spring from NRV valve. 7. Flush BOP with water via kil choke manifold - poor boy degasser. 8 9. |. Open 2-1/16" x 5 K side outlet valve in 13-5/8” CHH. Fill annulus with water, 10. Line up test u 11. Pressure test as per program attached to 300/3800 psi in 5/10 min (annular BOP to 3500 psi). 12. Break out test assy from test plug and POOH. 0 side entry sub with low torque valve. 13. Closed blind rams connect test line to kill line. 14. Close blind rams pressure test 300/ 3800 psi in 5-10 min, 15, Retrieve test plug. 16. Close 2-1/16" x 5K side outlet valve in 13-5/8” CHH. 17. Next operation rig up Tesco for running 9-5/8" csg. Detai structions followed. 18. Driller to make sure trip tank runs all time when wellbore open 19. Geoservice to monitor losses and report to WSS. Wwe to DO: Clean casing threads. Prepare test unit for BOP pressure test in advance. Check and confirma hoses. ittings are OK. Remember: fat any time you are not sure of something please ask, Page tot RIG DM 37 PUP JOINT 10 FT 300 LOW 3800 HIGH TLWVALVE, Lose: (3500 psi for annular) HYDRIL HYD. KILL LINE ENTRY SUB HYD. HCR TW VALVE 300 LOW - 3800 HIGH SINGLE JOINT TOP PIPE RAMS. MANUAL KILL LINE MANUAL HCR Lower kelly valve on TDS TEST PLUG 300 LOW - 3800 HIGH LOWER PIPE RAMS. IBOP on TOS (One stand 5" HWOI 300 LOW - 3800 HIGH BLIND RAMS ‘CONFLEX HOSE MASTER VALVE OF CHO. MAN

You might also like