You are on page 1of 3
Design Basic panel design, operation Basic panel design (example) ~ Duplex (back-to-back) 10 vt 1 Door to low-voltage compartment 2 Protection device 3 Option: Capacitive voltage detecting System for feeger and busbar 4 High-voltage coor 5 Handle fr high-voltage door 6 Mimic diagram 17 "CLOSE-OPEN” actuating openings forthe circuit breaker, opening for spring charging 8 inspection window to recognize the “CLOSED-OPEN" incicator ofthe circuit breaker, “elosng soring charged" indicator, operations counter {9 Actuating opening for racking the switching device 10 Mechanical postion indicator for feeder earthing switeh Switching-device compartment usbar compartment Connection compartment Withsrawable circuit breaker Low-voltage compartment 11 Actuating opening for feeder earthing switch, ‘manual or optionally mater operation 12 Mechanical position indicator for witherawable part, 18 Pressure relia duct, f requires with top-mounted arcabsorber r6 busbars 15 Bushing-type insulator 16 Block type current transformer 17 Voltage transformer 18 Cable connection 19 Mate proof earthing switch 20 Low voltage connection, plug-in type 21 Operating and interlocking unit for circuit breaker 22 Vacuum interrupters, 23 Contact system 24 Withdrawable par for racking the switching device and for earthing, manual or optionally ‘moter operation Airinsulated Medium-Veltage Switchgear NXAIR, up to 24 KY. Siemens HA 25.71 2016 Ls Technical data 24 kV Dimensions ‘Single busbar @ Double busbar (back-to-back arrangement) Weight HT 2 Hs 7 Hs Depth TH 2 Gircuit-beaker panel, disconnecting panel bus sectionaizer Metering pane! Siwteh-diconnector panel with HV HRC fuses Standard panel With high low-voltage compartment ‘With natural ventilation With optional are absorber? With addtional compartment fr busbar ‘components Single busbar Double busbar 1) Number of absorbers dependent on switchgear configuration #004 12504 2000 2500 12504, £25004, +800 200 +3000 1000 2800 2x1000 00 2510 2550 2680) 2750 270 1600 3350 00 800 1000 1000 2800 21000 00 2510 2550 2680) 2750 2770 1600 3350 800 00 1000 1000 2800 21000 800 2510 2550 2680 2750 2770 1600 3350 Airingulateg Medium: Voltage Switchgear NXAIR, upto 24 KY. Siemens HA 25.71 2036 Technical data 24 kV Room planning Pressure relief out of the switchgear room through a pressure relief duct Pressure relief into the switchgear room through absorbers, Geodon Lo, 00070020. DU,ga Sage WLW. ae g < il S| f f ! 4 | a Be 1 | a foi i PoocseaNewiwewes) F I55F Besson gee s0q Weores Soo Lateral pressure relief duct Rear pressure relief duct poco] ee “me NXAIR 24 kV x [fave eee Wo for single- busbar switchgear For imensions 8 (width) and T (epi), se table on page 27 ouble-busbar arrangement (top view) Forbaccto-back arrangement, a 1200 mm wide control aisle isrequted on the left or onthe right ofthe switchgear ‘ohave the possibilty (required) to bring a circutbreaker “380 from one ow tothe other 1) Forconnection trom the font = 150 mm for connection ‘rom the rear = 500 mm 2) For designs with a closed pressure elit duct tothe outside, a stance of = 500 mm s required an one side 3) Incase of alowerceling height, please contact your Siemens ma partner = Aivinsulated Medium-Votage Switchgear NXAIR, up to 24 KV. Siemens HA 25.71 2016

You might also like