You are on page 1of 18

Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 65C-160
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324017 Test number : 16388
Itemnumber : G-1102 A Pumpnumber : C111252001 Test date : 09-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 62.5 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 10 m Flowmeter no.: 7 Type : W22 - 3~112M-04
NPSH req. : m Make : Krohne Dn 100 Number : 1034532887
Power at duty : kW Inlet : 150 mm Power :3 kW Speed : 1760 rpm
Power act. dr. :3 kW Outlet : 100 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.31 m AC/DC : AC Cos phi : 0.79
Speed : 1750 rpm Vapour pr. : 0.211442 m Cw factor : 1.0 Current : 6.13 A
Density : 1000 kg/m3 Atm. press. : 1014 mbar
Temperature : °C Impeller : 164 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 87.2 89 89.5 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1484 1203.00 0.98 1.31 1.95
1485 886.00 0.98 1.57 1.86
1485 658.00 0.99 1.66 1.70
1487 443.00 0.99 1.72 1.55
1488 220.00 0.99 1.74 1.36
1490 0.00 1.00 1.74 1.23

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
72.18 0.27 4.94 88.57 1.73 85.12 6.87 2.81 2.81 56.27
53.16 0.14 7.47 88.34 1.64 62.65 10.38 2.67 2.67 65.85
39.48 0.08 8.22 87.93 1.50 46.52 11.42 2.42 2.42 59.15
26.58 0.04 8.79 87.55 1.36 31.28 12.17 2.19 2.19 46.90
13.20 0.01 8.97 87.17 1.19 15.52 12.40 1.91 1.91 27.21
0.00 0.00 8.86 86.53 1.06 0.00 12.22 1.70 1.70 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 10-03-2017


Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 65C-160
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324017 Test number : 16387
Itemnumber : G-1102 B Pumpnumber : C111252002 Test date : 09-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 62.5 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 10 m Flowmeter no.: 8 Type : W22 - 3~112M-04
NPSH req. : m Make : Krohne Dn 150 Number : 1034532886
Power at duty : kW Inlet : 200 mm Power :3 kW Speed : 1760 rpm
Power act. dr. :3 kW Outlet : 150 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.31 m AC/DC : AC Cos phi : 0.79
Speed : 1750 rpm Vapour pr. : 0.211442 m Cw factor : 1.0 Current : 6.13 A
Density : 1000 kg/m3 Atm. press. : 1014 mbar
Temperature : °C Impeller : 164 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 87.2 89 89.5 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1485 1196.00 0.99 1.39 1.86
1485 882.00 0.99 1.59 1.75
1487 651.00 0.99 1.69 1.59
1488 441.00 1.00 1.74 1.42
1490 228.00 1.00 1.76 1.23
1492 0.00 1.00 1.76 1.10

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
71.76 0.04 5.43 88.33 1.64 84.57 7.54 2.67 2.67 64.64
52.92 0.02 7.45 88.06 1.54 62.36 10.35 2.50 2.50 69.71
39.06 0.01 8.46 87.65 1.39 45.97 11.72 2.25 2.25 64.58
26.46 0.01 8.86 87.22 1.24 31.12 12.26 1.99 1.99 51.60
13.68 0.00 9.06 86.52 1.06 16.07 12.50 1.70 1.70 31.74
0.00 0.00 9.06 84.78 0.93 0.00 12.46 1.48 1.48 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 10-03-2017


Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 200-200
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324018 Test number : 16392
Itemnumber : G-1103 A Pumpnumber : C111252003 Test date : 13-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 275 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 20 m Flowmeter no.: 10 Type : W22 - 3~180M-04
NPSH req. : m Make : Krohne Dn 250 Number : 1034573299
Power at duty : kW Inlet : 250 mm Power : 22 kW Speed : 1775 rpm
Power act. dr. : 22 kW Outlet : 250 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.1 m AC/DC : AC Cos phi : 0.81
Speed : 1780 rpm Vapour pr. : 0.207482 m Cw factor : 1.0 Current : 41.7 A
Density : 1000 kg/m3 Atm. press. : 1023 mbar
Temperature : °C Impeller : 221 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 93 93.8 94 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1492 7010.00 0.91 1.46 13.50
1492 5480.00 0.94 1.93 13.80
1492 3840.00 0.96 2.18 12.80
1493 2415.00 0.98 2.31 11.90
1493 1205.00 0.98 2.38 11.00
1493 0.00 0.99 2.48 10.70

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
420.60 0.00 6.71 93.60 12.63 501.79 9.55 21.36 21.36 60.83
328.80 0.00 11.20 93.64 12.92 392.27 15.93 21.85 21.85 77.59
230.40 0.00 13.54 93.48 11.97 274.87 19.27 20.23 20.23 71.02
144.90 0.00 14.66 93.34 11.11 172.75 20.84 18.73 18.73 52.11
72.30 0.00 15.38 93.19 10.25 86.20 21.86 17.28 17.28 29.54
0.00 0.00 16.29 93.14 9.97 0.00 23.16 16.80 16.80 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 13-03-2017


Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 200-200
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324018 Test number : 16402
Itemnumber : G-1103 B Pumpnumber : C111252004 Test date : 15-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 275 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 20 m Flowmeter no.: 10 Type : W22 - 3~180M-04
NPSH req. : m Make : Krohne Dn 250 Number : 1034573300
Power at duty : kW Inlet : 250 mm Power : 22 kW Speed : 1775 rpm
Power act. dr. : 22 kW Outlet : 250 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.1 m AC/DC : AC Cos phi : 0.81
Speed : 1780 rpm Vapour pr. : 0.212776 m Cw factor : 1.0 Current : 41.7 A
Density : 1000 kg/m3 Atm. press. : 1031 mbar
Temperature : °C Impeller : 221 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 93 93.8 94 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1492 7015.00 0.91 1.45 13.30
1492 5530.00 0.95 1.92 13.70
1492 3840.00 0.97 2.19 12.60
1494 2400.00 0.99 2.34 11.70
1494 1210.00 0.99 2.41 10.80
1494 0.00 1.00 2.51 10.20

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
420.90 0.00 6.61 93.56 12.44 502.15 9.40 21.04 21.04 60.87
331.80 0.00 10.99 93.63 12.83 395.85 15.64 21.69 21.69 77.45
230.40 0.00 13.54 93.45 11.78 274.87 19.27 19.90 19.90 72.17
144.00 0.00 14.87 93.30 10.92 171.57 21.10 18.37 18.37 53.42
72.60 0.00 15.58 93.16 10.06 86.50 22.12 16.93 16.93 30.63
0.00 0.00 16.50 93.06 9.49 0.00 23.42 15.96 15.96 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 15-03-2017


Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 80C-200
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324019 Test number : 16445
Itemnumber : G-1104 A Pumpnumber : C111252005 Test date : 03-04-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 73 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 10 m Flowmeter no.: 9 Type : W22 - 3~112M-04
NPSH req. : m Make : Krohne Dn 200 Number : 1034532884
Power at duty : kW Inlet : 150 mm Power :3 kW Speed : 1760 rpm
Power act. dr. :3 kW Outlet : 150 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.27 m AC/DC : AC Cos phi : 0.79
Speed : 1750 rpm Vapour pr. : 0.225139 m Cw factor : 1.0 Current : 6.31 A
Density : 1000 kg/m3 Atm. press. : 1028 mbar
Temperature : °C Impeller : 161 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 87.2 89 89.5 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1483 1505.00 0.99 1.35 2.15
1483 1245.00 0.99 1.51 2.10
1484 1032.00 0.99 1.57 2.01
1485 708.00 1.00 1.68 1.95
1486 368.00 1.00 1.74 1.83
1486 0.00 1.00 1.76 1.81

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
90.30 0.00 4.94 89.02 1.91 106.56 6.88 3.12 3.12 63.50
74.70 0.00 6.57 88.95 1.87 88.15 9.15 3.05 3.05 71.59
61.92 0.00 7.18 88.72 1.78 73.02 9.99 2.90 2.90 67.96
42.48 0.00 8.20 88.57 1.73 50.06 11.39 2.80 2.80 54.97
22.08 0.00 8.82 88.27 1.61 26.00 12.23 2.62 2.62 32.83
0.00 0.00 9.02 88.21 1.60 0.00 12.51 2.58 2.58 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 02-05-2017


B119558-J01-04 Manufacturing Record Book Page 189
Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 80C-200
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324019 Test number : 16479
Itemnumber : G-1104 B Pumpnumber : C111252006 Test date : 01-05-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 73 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 10 m Flowmeter no.: 7 Type : W22 - 3~112M-04
NPSH req. : m Make : Krohne Dn 100 Number : 1034532888
Power at duty : kW Inlet : 150 mm Power :3 kW Speed : 1760 rpm
Power act. dr. :3 kW Outlet : 100 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.27 m AC/DC : AC Cos phi : 0.79
Speed : 1750 rpm Vapour pr. : 0.232283 m Cw factor : 1.0 Current : 6.13 A
Density : 1000 kg/m3 Atm. press. : 1010 mbar
Temperature : °C Impeller : 161 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 87.2 89 89.5 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1482 1504.00 0.96 1.27 2.15
1482 1254.00 0.97 1.43 2.10
1483 1036.00 0.98 1.52 2.02
1483 699.00 0.98 1.65 1.95
1484 353.00 0.99 1.71 1.81
1485 0.00 1.00 1.70 1.80

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
90.24 0.42 4.85 89.02 1.91 106.56 6.76 3.13 3.13 62.27
75.24 0.29 6.25 88.96 1.87 88.85 8.72 3.05 3.05 68.59
62.16 0.20 6.97 88.75 1.79 73.35 9.71 2.92 2.92 65.86
41.94 0.09 8.19 88.57 1.73 49.49 11.41 2.81 2.81 54.19
21.18 0.02 8.63 88.22 1.60 24.98 12.01 2.60 2.60 31.20
0.00 0.00 8.41 88.19 1.59 0.00 11.68 2.57 2.57 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 02-05-2017


B119558-J01-04 Manufacturing Record Book Page 191
Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 80C-200
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324019 Test number : 16480
Itemnumber : G-1104 C Pumpnumber : C111252007 Test date : 01-05-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 73 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 10 m Flowmeter no.: 8 Type : W22 - 3~112M-04
NPSH req. : m Make : Krohne Dn 150 Number : 1034532885
Power at duty : kW Inlet : 200 mm Power :3 kW Speed : 1760 rpm
Power act. dr. :3 kW Outlet : 150 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.27 m AC/DC : AC Cos phi : 0.79
Speed : 1750 rpm Vapour pr. : 0.232283 m Cw factor : 1.0 Current : 6.13 A
Density : 1000 kg/m3 Atm. press. : 1010 mbar
Temperature : °C Impeller : 161 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 87.2 89 89.5 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1481 1498.00 0.99 1.34 2.09
1481 1249.00 0.99 1.48 2.04
1482 1033.00 0.99 1.55 1.95
1483 691.00 0.99 1.66 1.88
1484 354.00 0.99 1.73 1.78
1487 0.00 1.00 1.71 1.77

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
89.88 0.07 4.91 88.94 1.86 106.20 6.85 3.04 3.04 64.66
74.94 0.05 6.32 88.81 1.81 88.55 8.82 2.97 2.97 71.15
61.98 0.03 7.01 88.58 1.73 73.19 9.78 2.82 2.82 68.56
41.46 0.01 8.12 88.40 1.66 48.92 11.30 2.71 2.71 55.16
21.24 0.00 8.82 88.14 1.57 25.05 12.27 2.55 2.55 32.52
0.00 0.00 8.51 88.12 1.56 0.00 11.79 2.52 2.52 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 02-05-2017


B119558-J01-04 Manufacturing Record Book Page 193
Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 80C-160
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324020 Test number : 16393
Itemnumber : G-1105 A Pumpnumber : C111252008 Test date : 13-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 84 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 10 m Flowmeter no.: 8 Type : W22 - 3~112M-04
NPSH req. : m Make : Krohne Dn 150 Number : 1034567184
Power at duty : kW Inlet : 200 mm Power : 4.5 kW Speed : 1745 rpm
Power act. dr. : 4.5 kW Outlet : 150 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.31 m AC/DC : AC Cos phi : 0.8
Speed : 1750 rpm Vapour pr. : 0.208794 m Cw factor : 1.0 Current : 9.08 A
Density : 1000 kg/m3 Atm. press. : 1022 mbar
Temperature : °C Impeller : 159 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 88.7 89.5 89.5 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1483 2005.00 0.99 1.32 2.80
1484 1600.00 0.99 1.48 2.70
1484 1187.00 0.99 1.58 2.50
1485 790.00 0.99 1.66 2.40
1487 404.00 1.00 1.69 2.20
1488 0.00 1.00 1.68 2.10

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
120.30 0.13 4.80 89.20 2.50 141.96 6.68 4.07 4.07 62.97
96.00 0.08 6.39 89.12 2.41 113.21 8.88 3.91 3.91 69.41
71.22 0.04 7.37 88.97 2.22 83.99 10.25 3.62 3.62 64.29
47.40 0.02 8.16 88.90 2.13 55.86 11.33 3.46 3.46 49.38
24.24 0.01 8.35 88.75 1.95 28.53 11.57 3.15 3.15 28.25
0.00 0.00 8.24 88.70 1.86 0.00 11.40 3.00 3.00 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 14-03-2017


Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 80C-160
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324020 Test number : 16398
Itemnumber : G-1105 B Pumpnumber : C111252009 Test date : 13-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 84 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 10 m Flowmeter no.: 8 Type : W22 - 3~112M-04
NPSH req. : m Make : Krohne Dn 150 Number : 1034567185
Power at duty : kW Inlet : 200 mm Power : 4.5 kW Speed : 1745 rpm
Power act. dr. : 4.5 kW Outlet : 150 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.31 m AC/DC : AC Cos phi : 0.8
Speed : 1750 rpm Vapour pr. : 0.208794 m Cw factor : 1.0 Current : 9.08 A
Density : 1000 kg/m3 Atm. press. : 1029 mbar
Temperature : °C Impeller : 159 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 88.7 89.5 89.5 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1484 2010.00 0.99 1.33 2.70
1484 1595.00 1.00 1.50 2.60
1485 1187.00 1.00 1.59 2.40
1486 800.00 1.00 1.66 2.30
1487 409.00 1.00 1.69 2.10
1488 0.00 1.00 1.68 2.10

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
120.60 0.13 4.90 89.12 2.41 142.22 6.82 3.91 3.91 66.93
95.70 0.08 6.49 89.05 2.31 112.85 9.02 3.76 3.76 73.05
71.22 0.04 7.37 88.90 2.13 83.93 10.23 3.46 3.46 67.00
48.00 0.02 8.06 88.82 2.04 56.53 11.18 3.31 3.31 51.59
24.54 0.01 8.35 88.70 1.86 28.88 11.57 3.00 3.00 29.97
0.00 0.00 8.24 88.70 1.86 0.00 11.40 3.00 3.00 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 14-03-2017


Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 125-250
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324021 Test number : 16435
Itemnumber : G-1106 A Pumpnumber : C111252010 Test date : 28-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 187.5 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 20 m Flowmeter no.: 8 Type : W22 - 3~160M-04
NPSH req. : m Make : Krohne Dn 150 Number : 1034573301
Power at duty : kW Inlet : 200 mm Power : 15 kW Speed : 1475 rpm
Power act. dr. : 15 kW Outlet : 150 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.16 m AC/DC : AC Cos phi : 0.71
Speed : 1780 rpm Vapour pr. : 0.218193 m Cw factor : 1.0 Current : 34.3 A
Density : 1000 kg/m3 Atm. press. : 1021 mbar
Temperature : °C Impeller : 226 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 86 88.5 89 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1491 3721.00 0.95 1.57 10.20
1491 3100.00 0.96 1.99 10.10
1491 2606.00 0.97 2.24 9.60
1492 1838.00 0.98 2.45 8.60
1493 928.00 0.99 2.59 7.30
1494 0.00 0.99 2.57 6.10

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
223.26 0.43 7.91 86.99 8.87 266.53 11.28 15.01 15.01 54.22
186.00 0.30 11.96 86.93 8.78 222.05 17.05 14.85 14.85 69.03
156.36 0.21 14.32 86.64 8.32 186.67 20.41 14.06 14.06 73.34
110.28 0.10 16.25 86.05 7.40 131.57 23.14 12.48 12.48 65.99
55.68 0.03 17.50 85.89 6.27 66.38 24.88 10.54 10.54 42.34
0.00 0.00 17.27 84.86 5.18 0.00 24.52 8.67 8.67 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 03-04-2017


B119558-J01-06 Manufacturing record Book Page 183
Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 125-250
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324021 Test number : 16437
Itemnumber : G-1106 B Pumpnumber : C111252011 Test date : 29-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 187.5 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 20 m Flowmeter no.: 8 Type : W22 - 3~160M-04
NPSH req. : m Make : Krohne Dn 150 Number : 1034573302
Power at duty : kW Inlet : 200 mm Power : 15 kW Speed : 1475 rpm
Power act. dr. : 15 kW Outlet : 150 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.16 m AC/DC : AC Cos phi : 0.71
Speed : 1780 rpm Vapour pr. : 0.218193 m Cw factor : 1.0 Current : 34.3 A
Density : 1000 kg/m3 Atm. press. : 1022 mbar
Temperature : °C Impeller : 226 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 86 88.5 89 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1490 3722.00 0.96 1.63 10.10
1490 3100.00 0.97 2.04 9.80
1491 2607.00 0.98 2.30 9.40
1492 1819.00 0.98 2.50 8.20
1494 920.00 0.99 2.62 6.90
1495 0.00 0.99 2.57 5.70

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
223.32 0.43 8.42 86.93 8.78 266.79 12.02 14.88 14.88 58.35
186.00 0.30 12.37 86.76 8.50 222.20 17.65 14.41 14.41 73.71
156.42 0.21 14.83 86.52 8.13 186.74 21.14 13.75 13.75 77.70
109.14 0.10 16.76 86.00 7.05 130.21 23.86 11.89 11.89 70.67
55.20 0.03 17.81 85.72 5.91 65.77 25.28 9.91 9.91 45.28
0.00 0.00 17.27 84.08 4.79 0.00 24.48 8.00 8.00 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 03-04-2017


B119558-J01-06 Manufacturing record Book Page 185
Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 125-250
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324021 Test number : 16442
Itemnumber : G-1106 C Pumpnumber : C111252012 Test date : 31-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 187.5 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 20 m Flowmeter no.: 8 Type : W22 - 3~160M-04
NPSH req. : m Make : Krohne Dn 150 Number : 1034573303
Power at duty : kW Inlet : 200 mm Power : 15 kW Speed : 1475 rpm
Power act. dr. : 15 kW Outlet : 150 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.16 m AC/DC : AC Cos phi : 0.71
Speed : 1780 rpm Vapour pr. : 0.225139 m Cw factor : 1.0 Current : 34.3 A
Density : 1000 kg/m3 Atm. press. : 1014 mbar
Temperature : °C Impeller : 226 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 86 88.5 89 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1492 3698.00 0.97 1.57 9.70
1492 3111.00 0.97 1.96 9.60
1492 2625.00 0.97 2.23 9.20
1493 1802.00 0.97 2.47 8.10
1494 920.00 0.98 2.60 6.90
1495 0.00 0.98 2.56 5.80

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
221.88 0.42 7.70 86.69 8.41 264.71 10.96 14.19 14.19 55.36
186.66 0.30 11.55 86.63 8.32 222.69 16.45 14.03 14.03 70.64
157.50 0.21 14.22 86.40 7.95 187.90 20.24 13.41 13.41 76.77
108.12 0.10 16.56 86.00 6.97 128.90 23.53 11.72 11.72 70.00
55.20 0.03 17.70 85.71 5.91 65.77 25.13 9.91 9.91 45.02
0.00 0.00 17.27 84.29 4.89 0.00 24.48 8.16 8.16 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 03-04-2017


B119558-J01-06 Manufacturing record Book Page 187
Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 32-200
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324022 Test number : 16447
Itemnumber : G-1107 A Pumpnumber : C111252013 Test date : 04-04-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 20 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 65 m Flowmeter no.: 7 Type : W22 - 3~132M-02
NPSH req. : m Make : Krohne Dn 100 Number : 1034532890
Power at duty : kW Inlet : 150 mm Power : 9.2 kW Speed : 3525 rpm
Power act. dr. : 9.2 kW Outlet : 100 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.31 m AC/DC : AC Cos phi : 0.89
Speed : 3500 rpm Vapour pr. : 0.223734 m Cw factor : 1.0 Current : 16.4 A
Density : 1000 kg/m3 Atm. press. : 1025 mbar
Temperature : °C Impeller : 191 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 89.6 90.8 91.2 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
2969 456.00 1.00 4.47 6.80
2971 364.00 1.00 5.05 6.20
2974 277.00 1.00 5.51 5.60
2977 180.00 1.00 5.88 4.90
2980 89.00 1.00 6.07 4.30
2984 0.00 1.00 6.05 3.70

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
27.36 0.04 36.73 90.88 6.18 32.25 51.05 10.06 10.06 44.30
21.84 0.02 42.63 90.70 5.62 25.73 59.16 9.13 9.13 45.10
16.62 0.01 47.31 90.36 5.06 19.56 65.53 8.18 8.18 42.33
10.80 0.01 51.08 89.97 4.41 12.70 70.60 7.10 7.10 34.09
5.34 0.00 53.01 89.63 3.85 6.27 73.12 6.18 6.18 20.01
0.00 0.00 52.80 89.38 3.31 0.00 72.65 5.27 5.27 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 20-04-2017


B119558-J01-07 Manufacturing Record Book Page 187
Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 32-200
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324022 Test number : 16430
Itemnumber : G-1107 B Pumpnumber : C111252014 Test date : 24-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity : 20 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 65 m Flowmeter no.: 7 Type : W22 - 3~132M-02
NPSH req. : m Make : Krohne Dn 100 Number : 1034532889
Power at duty : kW Inlet : 150 mm Power : 9.2 kW Speed : 3525 rpm
Power act. dr. : 9.2 kW Outlet : 100 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.31 m AC/DC : AC Cos phi : 0.88
Speed : 3500 rpm Vapour pr. : 0.214119 m Cw factor : 1.0 Current : 16.4 A
Density : 1000 kg/m3 Atm. press. : 1031 mbar
Temperature : °C Impeller : 191 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 89.6 90.8 91.2 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
2966 452.00 1.01 4.43 6.80
2968 367.00 1.01 5.00 6.20
2973 279.00 1.01 5.50 5.60
2977 181.00 1.01 5.88 4.90
2979 92.00 1.02 6.04 4.30
2983 0.00 1.02 6.04 3.70

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
27.12 0.04 36.22 90.88 6.18 32.00 50.44 10.09 10.09 43.30
22.02 0.03 42.02 90.71 5.62 25.97 58.44 9.16 9.16 44.82
16.74 0.01 47.11 90.37 5.06 19.71 65.29 8.19 8.19 42.45
10.86 0.01 50.98 89.97 4.41 12.77 70.46 7.10 7.10 34.20
5.52 0.00 52.50 89.63 3.85 6.49 72.47 6.19 6.19 20.48
0.00 0.00 52.50 89.38 3.31 0.00 72.27 5.28 5.28 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 20-04-2017


B119558-J01-07 Manufacturing Record Book Page 189
Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 25-125
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324023 Test number : 16433
Itemnumber : G-1108 A Pumpnumber : C111252015 Test date : 28-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity :4 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 20 m Flowmeter no.: 6 Type : W22 - 3~80-02
NPSH req. : m Make : Krohne Dn 50 Number : 1034675574
Power at duty : kW Inlet : 100 mm Power : 1.1 kW Speed : 2825 rpm
Power act. dr. : 1.1 kW Outlet : 50 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.39 m AC/DC : AC Cos phi : 0.73
Speed : 3500 rpm Vapour pr. : 0.216827 m Cw factor : 1.0 Current : 2.7 A
Density : 1000 kg/m3 Atm. press. : 1020 mbar
Temperature : °C Impeller : 104 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 77 80 80.5 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
2934 100.00 1.02 2.05 0.85
2937 74.00 1.02 2.19 0.78
2938 56.00 1.02 2.22 0.75
2944 25.00 1.02 2.32 0.68
2953 0.00 1.02 2.39 0.58

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
6.00 0.03 11.93 78.19 0.67 7.16 16.97 1.05 1.05 29.32
4.44 0.02 13.34 77.59 0.60 5.29 18.94 0.95 0.95 26.67
3.36 0.01 13.64 77.34 0.58 4.00 19.35 0.91 0.91 21.52
1.50 0.00 14.65 76.90 0.52 1.78 20.70 0.80 0.80 11.44
0.00 0.00 15.36 74.78 0.43 0.00 21.58 0.65 0.65 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 04-04-2017


B119558-J01-08 Manufacturing Record Book Page 182
Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR25-125
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324023 Test number : 16426
Itemnumber : G-1108 B Pumpnumber : C111252016 Test date : 22-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity :4 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 20 m Flowmeter no.: 6 Type : W22 - 3~80-02
NPSH req. : m Make : Krohne Dn 50 Number : 1034675575
Power at duty : kW Inlet : 100 mm Power : 1.1 kW Speed : 2825 rpm
Power act. dr. : 1.1 kW Outlet : 50 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.39 m AC/DC : AC Cos phi : 0.73
Speed : 3500 rpm Vapour pr. : 0.216827 m Cw factor : 1.0 Current : 2.7 A
Density : 1000 kg/m3 Atm. press. : 1015 mbar
Temperature : °C Impeller : 104 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 77 80 80.5 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
2928 101.00 1.01 1.80 0.88
2932 74.50 1.01 2.14 0.82
2936 57.00 1.01 2.21 0.77
2943 25.00 1.01 2.30 0.70
2952 0.00 1.01 2.37 0.63

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
6.06 0.04 9.48 78.46 0.69 7.24 13.55 1.10 1.10 22.68
4.47 0.02 12.93 77.95 0.64 5.34 18.43 1.01 1.01 24.64
3.42 0.01 13.64 77.52 0.60 4.08 19.38 0.94 0.94 21.28
1.50 0.00 14.55 76.99 0.54 1.78 20.57 0.83 0.83 11.03
0.00 0.00 15.26 76.22 0.48 0.00 21.45 0.73 0.73 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 04-04-2017


B119558-J01-08 Manufacturing Record Book Page 184
Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 32A-160
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324024 Test number : 16405
Itemnumber : G-1109-A Pumpnumber : C111252017 Test date : 15-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity :4 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 10 m Flowmeter no.: 7 Type : W22 - 3~80-04
NPSH req. : m Make : Krohne Dn 100 Number : 1034609563
Power at duty : kW Inlet : 150 mm Power : 0.55 kW Speed : 1720 rpm
Power act. dr. : 0.55 kW Outlet : 100 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.36 m AC/DC : DC Cos phi : 0.8
Speed : 1750 rpm Vapour pr. : 0.214119 m Cw factor : 1.0 Current : 1.23 A
Density : 1000 kg/m3 Atm. press. : 1032 mbar
Temperature : °C Impeller : 146 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 78 79 81.1 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1473 176.00 1.01 1.21 0.43
1473 137.00 1.01 1.39 0.40
1477 107.00 1.01 1.49 0.38
1479 73.00 1.01 1.56 0.35
1483 38.00 1.02 1.61 0.31
1485 0.00 1.02 1.62 0.28

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
10.56 0.01 3.40 78.96 0.34 12.55 4.81 0.54 0.54 28.81
8.22 0.00 5.24 78.75 0.32 9.77 7.39 0.49 0.49 37.23
6.42 0.00 6.26 78.62 0.30 7.61 8.78 0.46 0.46 36.60
4.38 0.00 6.97 78.41 0.27 5.18 9.76 0.42 0.42 30.35
2.28 0.00 7.38 78.14 0.24 2.69 10.27 0.36 0.36 18.93
0.00 0.00 7.48 77.80 0.22 0.00 10.38 0.32 0.32 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 21-03-2017


Test sheet

Customer References Johnson References


Customer : ION Exchange (India) Limited Pumptype : CCR 32A-160
Ordernumber : 2016-2017/01/012/N/00111/058096150028 Ordernumber : 324024 Test number : 16414
Itemnumber : G-1109 B Pumpnumber : C111252018 Test date : 17-03-2017
Pumpnumber : Approved by : K.J.Struik

Guarantee Data Test Data Motor Data


Capacity :4 m3/h Flowmeter : Electromagn. Make : WEG
Total Head : 10 m Flowmeter no.: 6 Type : W22 - 3~80-04
NPSH req. : m Make : Krohne Dn 50 Number : 1034609562
Power at duty : kW Inlet : 100 mm Power : 0.55 kW Speed : 1720 rpm
Power act. dr. : 0.55 kW Outlet : 50 mm Voltage : 400 V Cycles : 60 Hz
Efficiency : % Corr. Head : 1.35 m AC/DC : AC Cos phi : 0.8
Speed : 1750 rpm Vapour pr. : 0.218193 m Cw factor : 1.0 Current : 1.23 A
Density : 1000 kg/m3 Atm. press. : 1014 mbar
Temperature : °C Impeller : 146 mm 50% 75% 100%
Flanges suct. : mm Orifice : mm Efficiency 78 79 81.1 %
Flange disch. : mm Backvanes : mm
Viscosity :1 mm2/s Mat. code : R4GE

Q-H Readings test stand


N [rpm] Q [l/min] P1 [bar] P2 [bar] P [kW]
1469 180.00 1.01 1.16 0.47
1469 145.00 1.01 1.33 0.46
1471 104.00 1.01 1.46 0.43
1474 68.00 1.01 1.54 0.39
1478 33.00 1.01 1.57 0.35
1481 0.00 1.01 1.58 0.33

Calculated results Specified conditions


Q [m3/h] V [m] H [m] eff M [%] Pw [kW] Q [m3/h] H [m] Pw [kW] Pl [kW] eff P [%]
10.80 0.11 2.99 79.52 0.37 12.87 4.25 0.60 0.60 23.54
8.70 0.07 4.68 79.37 0.36 10.36 6.65 0.58 0.58 30.42
6.24 0.04 5.98 78.97 0.34 7.42 8.46 0.54 0.54 29.88
4.08 0.02 6.77 78.69 0.31 4.84 9.54 0.48 0.48 24.51
1.98 0.00 7.06 78.42 0.27 2.34 9.90 0.42 0.42 13.91
0.00 0.00 7.16 78.28 0.26 0.00 10.00 0.39 0.39 0.00

Remarks

Copyright SPX Flow Technology Assen B.V. 21-03-2017