Professional Documents
Culture Documents
Certofix® central venous catheters from B. Braun combine excellent Kink-proof guide wire
manufacturing quality with user appreciated individual components. Highly flexible and resilient guide wire made
Sharing Expertise with our customers enabled us to develop each out of Nitinol, with length markings
component according to the high standard in the medical field. Without compromising stiffness. The guide wire
Quick, blood-free introduction of The air-tight valve guarantees a closed of contact with the vessel wall
the guide wire via the side port adapter system with every disconnection of Optimal surface with exceptional
of the valve needle syringe or infusion line to avoid air gliding features
Smart geometry for easy handling embolism
independent from chosen puncture Allows infusion and blood withdrawal
2
Puncturing with ultrasound Puncturing with direct visual control
Ultrasound application for positioning of intravenous catheters The Certofix® Seldinger needle and anatomical structure
is recommended in international guidelines. It enhances safety are well visible using the out-of-plane (transversal) as
in anatomical investigation and puncturing. When using the well as the in-plane (sagittal) method.
ultrasound probe, sterility and the correct dimensions of the
equipment are important factors.
ECG-lead technique
1 Enables immediate corrective measures,
3
Certofix®
proximal
proximal
middle 2
proximal middle
middle 1
distal distal distal
4
Certofix® Highflow
proximal proximal
middle 3
middle 2
middle
middle 1
distal distal
User benefits
12F catheter size ensures excellent stability
and flexibility
Additional stable fixation wing at the point
5
Certofix® Mono
Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG-Cable Valve /
(REF) øG (ml/min) * (cm) Length Seldinger needle Plug
Material
(cm)
D 23
Mono S 215 4160185 18 15 50 Steel Seldinger needle n -
Additional information:
n The sales unit of Certofix® Mono Sets is 10 pcs.
6
Certofix® Duo / Certofix® Trio
Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG- Mini Valve /
(REF) øG (ml/min) * (cm) Length Seldinger needle Cable Scalpel Plug
Material
(cm)
Duo S 715 4164158 16/16 D 60; P 50 15 50 Nitinol Seldinger needle n n Safsite® Valve
Duo V 715 4166159 16/16 D 60; P 50 15 50 Nitinol Valve needle n n Safsite® Valve
Duo S 720 4167385 16/16 D 55; P 45 20 50 Nitinol Seldinger needle n n Safsite® Valve
Duo V 720 4161211 16/16 D 55; P 45 20 50 Nitinol Valve needle n n Safsite® Valve
Duo S 730 4167394 16/16 D 52; P 37 30 70 Nitinol Seldinger needle n n Safsite® Valve
Duo V 730 4161319 16/16 D 52; P 37 30 70 Nitinol Valve needle n n Safsite® Valve
Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG- Mini Valve /
(REF) øG (ml/min) * (cm) Length Seldinger needle Cable Scalpel Plug
Material
(cm)
Trio S 715 4161159 16/18/18 D 50; M1 28; P 28 15 50 Nitinol Seldinger needle n n Safsite® Valve
Trio V 715 4162153 16/18/18 D 50; M1 28; P 28 15 50 Nitinol Valve needle n n Safsite® Valve
Trio S 720 4167408 16/18/18 D 46; M1 22; P 22 20 50 Nitinol Seldinger needle n n Safsite® Valve
Trio V 720 4163214 16/18/18 D 46; M1 22; P 22 20 50 Nitinol Valve needle n n Safsite® Valve
Trio S 730 4163306 16/18/18 D 38; M1 18; P 18 30 70 Nitinol Seldinger needle n n Safsite® Valve
Trio V 730 4163311 16/18/18 D 38; M1 18; P 18 30 70 Nitinol Valve needle n n Safsite® Valve
Additional information:
n The sales unit of Certofix® Duo and Trio Sets is 10 pcs.
7
Certofix® Quattro / Certofix® Quinto
Product Type Code No. Cath. Lumen ø G Flow rate Length Guide wire Valve needle/
(REF) (ml/min) * (cm) Length (cm) Seldinger needle
Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/
(REF) øG (ml/min) * (cm) Length (cm) Seldinger needle
Quinto V 1215 4166841 16/18/18/18/12 D 65; M1 32; M2 32; M3 30; P 225 15 50 Valve needle
Quinto S 1220 4166852 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50 Seldinger needle
Quinto V 1220 4166868 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50 Valve needle
Additional information:
n The sales unit of Certofix® Quattro and Quinto Sets is 10 pcs.
8
Certofix® Highflow / Certofix® Accessories
Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/
(REF) øG (ml/min) * (cm) length (cm) Seldinger needle
Additional information:
n The sales unit of Certofix® Highflow Sets is 10 pcs.
Certodyn® Universal Adapter Paed 4150724 Electronic switch box (for paediatrics)
9
Certofix® Econoline
convenient storage
10
Certofix® Econoline
Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG- Valve /
(REF) øG (ml/min) * (cm) Length Seldinger needle Cable Plug
Material
(cm)
Mono 215 Econoline 4160185E 18 D 16 15 50 Steel Seldinger needle - IN-Stopper
Duo 715 Econoline 4164156E 16/16 D 60; P 50 15 50 Steel Seldinger needle - IN-Stopper
Duo 720 Econoline 4162200E 16/16 D 55; P 45 20 50 Steel Seldinger needle - IN-Stopper
Duo 730 Econoline 4162307E 16/16 D 52; P 37 20 70 Steel Seldinger needle - IN-Stopper
Trio 715 Econoline 4161157E 16/18/18 D 50; M1 28; P 28 15 50 Steel Seldinger needle - IN-Stopper
Trio 720 Econoline 4163206E 16/18/18 D 46; M1 22; P 22 20 50 Steel Seldinger needle - IN-Stopper
Trio 730 Econoline 4163303E 16/18/18 D 38; M1 18; P 18 30 70 Steel Seldinger needle - IN-Stopper
Additional information:
n The sales unit of Certofix® Econoline Sets is 10 pcs.
11
Certofix®
Interaction of a
microorganism with
the catheter surface
Efficacy spectrum
Gram-positive bacteria (St. aureus, St. epidermidis)
Days
Long-term protection
Even after weeks, the Certofix® protect catheter material exhibits an
effective level of protection against catheter colonization. After 30 days,
Certofix® protect still shows an efficacy of 75%.
12
Product Type Code No. Cath. Lumen Flow rate Length Guide wire Mini Valve /
(REF) øG (ml/min) * (cm) Length (cm) Scalpel Plug
Trio HF V 1220 Protect 4160622P 16/12/12 D 55; M1 165; P 165 20 50 n Safsite® Valve
Quattro V 815 Protect 4167767P 14/18/18/16 D 50; M1 20; M2 20; P 50 15 50 n Safsite® Valve
Quattro V 820 Protect 4167775P 14/18/18/16 D 40; M1 15; M2 15; P 40 20 50 n Safsite® Valve
Quattro V 830 Protect 4167783P 14/18/18/16 D 35; M1 10; M2 10; P 35 30 70 n Safsite® Valve
Quinto V 1220 Protect 4166868P 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50 n Safsite® Valve
The base material of the central venous catheter Certofix® protect consists of polyurethane (PUR). All lumens, including the hub and
the outer surface of the catheter, are coated with a long-chain polymer based on methacrylat. Catheters contain hydrophilic side
groups such as polyethylene glycol and antiseptic polymeric biguanide side groups.
Additional information:
n The sales unit of Certofix® protect Sets is 10 pcs.
13
Certofix® Paed
... for children´s safety
14
Kink-proof guide wire Teddy Bear fixation Introducer guide for guide wire
Extreme flexible and resilient guide wire Safe and easy catheter fixation without stich Improves threading of the “J” tip of the
made of Nitinol Soft to the skin of babies and newborns guide wire into the Seldinger needle
Guide wire with the right stiffness for Gentle removing possible Allows dispenser-free advancing of the
Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve /
(REF) øG (ml/min) * (cm) ø / Length (cm) Plug
Trio Paed S 508 4167228 20/22/22 D 30; M1 15; P 15 8 0,46/50 Safsite® Valve
Trio Paed S 513 4167244 20/22/22 D 29; M1 10; P 10 13 0,46/50 Safsite® Valve
Additional information:
The sales unit of Certofix® Paed Sets is 10 pcs.
15
Certofix® Safety
Increased safety for users
A broad variety of puncture needles and scalpels for incisions The Seldinger puncture needle has an active safety mechanism.
are used. The operating space and sterility during catheter The safety clip surrounds the needle tip as soon as it is deployed,
application often complicates the immediate disposal of sharp so medical personnel is well protected during operation
instruments. and disposal. It is possible to activate the clip, while the
With Certofix® Safety, B. Braun is enhancing the product cannula is guided over the guide wire.
portfolio for safe venous access.
During application, the plastic housing with safety clip is located next to
the needle hub. Once the guide wire has been placed in its desired position,
the safety clip, covered by the hub has to be forwarded onto skin level.
While simultaneously activating the safety mechanism, the needle is
withdrawn with the index finger.
After the protecting cover has been removed, the scalpel is moved forward
with the help of the green button until it snaps in and pushed back after
the incision.
User benefits
Small design of safety mechanism does not
16
Seldinger Needle Safety
Puncture needle with active safety mechanism to protect
against needle stick injuries. The integrated clip does not affect
puncturing procedure and can be activated single-handedly.
2 3
When the tip of the needle is reached, the safety clip activates automatically Once the needle has been completely pulled back behind the wire, the safety
and covers the needle tip already. clip envelopes the tip irreversibly.The needle and the plastic hub can now be
disposed in the usual way.
II III
Latching-mechanism
appears in the window.
Before the blade is finally secured, the scalpel can be held in a „parking position“ Once the blade has been withdrawn to the hilt/to the end of the press-button
enabling it to be handed over to other medical personnel. function, the safety mechanism activates. The scalpel is safe to be discarded.
Scalpel Safety
Stable, easy-to-use safety scalpel with safety mechanism
for the securing of the blade after incision.
17
Certofix® Safety
Product Type Code No. Cath. Lumen Flow rate Length Guide wire
(REF) øG (ml/min) * (cm) Length (cm)
Quinto S 1220 Safety 4166852S 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50
Additional information:
n The sales unit of Certofix® Safety Sets is 10 pcs.
18
Notes
19
B. Braun Melsungen AG | Hospital Care | 34209 Melsungen | Germany
Tel +49 56 61 71-0 | www.bbraun.com