Certofix® Central Venous Catheter Sets

Uncompromising Quality for Safe Infusion Therapy

Central Venous Catheters


Certofix®
... devices for safe central venous catheter placement

Certofix® central venous catheters from B. Braun combine excellent Kink-proof guide wire
manufacturing quality with user appreciated individual components. „ Highly flexible and resilient guide wire made

Sharing Expertise with our customers enabled us to develop each out of Nitinol, with length markings
component according to the high standard in the medical field. „ Without compromising stiffness. The guide wire

characteristics are well suitable for easy advancing


MORE CERTAINTY, MORE SAFETY, MORE SUCCESS through venous obstructions
„ “J” and straight tip are interchangeable and as

such the guide wire direction can be changed

Valve needle (V)

Seldinger needle (S)


“J” tip & Soft tip

Puncture needle Safsite® valve Soft tip / “J” tip


„ Easy cannulation of the vein either „ Safsite® simplifies the daily changing „ The special tip material (PUR) is more
with standard Seldinger needle (S) of the infusion system on central venous pliant and softer than the catheter body
or Valve needle (V) catheters and improves hygiene „ Best protection of the intima in case

„ Quick, blood-free introduction of „ The air-tight valve guarantees a closed of contact with the vessel wall
the guide wire via the side port adapter system with every disconnection of „ Optimal surface with exceptional

of the valve needle syringe or infusion line to avoid air gliding features
„ Smart geometry for easy handling embolism
independent from chosen puncture „ Allows infusion and blood withdrawal

needle without flow restriction

2
Puncturing with ultrasound Puncturing with direct visual control
Ultrasound application for positioning of intravenous catheters The Certofix® Seldinger needle and anatomical structure
is recommended in international guidelines. It enhances safety are well visible using the out-of-plane (transversal) as
in anatomical investigation and puncturing. When using the well as the in-plane (sagittal) method.
ultrasound probe, sterility and the correct dimensions of the
equipment are important factors.

ECG-lead technique
1 „ Enables immediate corrective measures,

if the initial positioning of the catheter


2 tip was to deep
„ Helps to prevent subsequent complications,

1 2 particularly the risk of pericardial perforation

3
Certofix®

Broad range of choices for any application


B. Braun offers a comprehensive portfolio of premium central
venous catheter sets. From single lumen catheters for short term
intervention to quintuple lumen catheters on the critical care
ward – B. Braun provides solutions for all application areas.
Different catheter geometries enable to infuse drugs and
solutions at any desired flow rate.

Mono Duo Trio Quattro

proximal

proximal
middle 2
proximal middle
middle 1
distal distal distal

User benefits Product specifications


Safe and certain positioning
„„ Radio-opaque polyurethane catheter, with soft
- Kink-proof guide wire tip, length markings, junction hub for stitch
- Real-time ECG-lead position verification fi­xation and fully transparent extension lines,
CVC insertion – the safety approach
„„ with color-coded hub and white slide clamps.
- Safsite® valves Components: Kink-proof guide wire with “J” tip
- Clear connection lines and straight tip on dispenser, movable fixation
- Kink-resistant catheter material wing with clamp, introducer needle (either
- Atraumatic catheter soft tip Seldinger or valve needle), scalpel, dilator, ECG-
Avoid drug incompatibility
„„ lead cable, Safsite® valve, 5 ml Omnifix® luer lock
- multi-lumen catheters up to 5 connection lines syringe (depending on set configuration)

4
Certofix® Highflow

Special solutions for volume- intensive infusion therapy


The large-sized channels are designed for high-volume
fluid substitution in short periods as well as veno-venous
acute dialysis.

Quinto Duo / Trio

proximal proximal

middle 3
middle 2
middle
middle 1
distal distal

User benefits
12F catheter size ensures excellent stability
„„

and flexibility
Additional stable fixation wing at the point
„„

where channels divide


For acute dialysis (double opening, proximal
„„

lumen), and high flow rates


Also available with antimicrobial effect
„„

to prevent from catheter-associated


infections – Certofix® protect

5
Certofix® Mono

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG-Cable Valve /
(REF) øG (ml/min) * (cm) Length Seldinger needle Plug
Material
(cm)
D 23
Mono S 215 4160185 18 15 50 Steel Seldinger needle n -

Mono S 315 4160223 16 D 60 15 50 Steel Seldinger needle n -

Mono V 315 4160231 16 D 60 15 50 Steel Valve needle n -

Mono S 415 4160509 14 D 90 15 50 Steel Seldinger needle n -

Mono V 415 4160517 14 D 90 15 50 Steel Valve needle n -

Mono S 220 4160207 18 D 18 20 50 Steel Seldinger needle n -

Mono V 220 4160215 18 D 18 20 50 Steel Valve needle n -

Mono S 320 4160258 16 D 52 20 50 Steel Seldinger needle n -

Mono V 320 4160266 16 D 52 20 50 Steel Valve needle n -

Mono SN 320 4160258N 16 D 52 20 50 Nitinol Seldinger needle n -

Mono VN 320 4160266N 16 D 52 20 50 Nitinol Valve needle n -

Mono S 420 4160304 14 D 80 20 50 Steel Seldinger needle n -

Mono V 420 4160320 14 D 80 20 50 Steel Valve needle n -

Mono SN 420 4160304N 14 D 80 20 50 Nitinol Seldinger needle n -

Mono VN 420 4160320N 14 D 80 20 50 Nitinol Valve needle n -

Mono S 330 4160282 16 D 40 30 70 Steel Seldinger needle n -

Mono V 330 4160290 16 D 40 30 70 Steel Valve needle n -

Mono SN 330 4160282N 16 D 40 30 70 Nitinol Seldinger needle n -

Mono VN 330 4160290N 16 D 40 30 70 Nitinol Valve needle n -

Mono S 430 4160762 14 D 75 30 70 Steel Seldinger needle n -

Mono V 430 4160789 14 D 75 30 70 Steel Valve needle n -

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
n The sales unit of Certofix® Mono Sets is 10 pcs.

n All catheters are made of PUR

6
Certofix® Duo / Certofix® Trio

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG- Mini Valve /
(REF) øG (ml/min) * (cm) Length Seldinger needle Cable Scalpel Plug
Material
(cm)
Duo S 715 4164158 16/16 D 60; P 50 15 50 Nitinol Seldinger needle n n Safsite® Valve

Duo V 715 4166159 16/16 D 60; P 50 15 50 Nitinol Valve needle n n Safsite® Valve

Duo S 720 4167385 16/16 D 55; P 45 20 50 Nitinol Seldinger needle n n Safsite® Valve

Duo V 720 4161211 16/16 D 55; P 45 20 50 Nitinol Valve needle n n Safsite® Valve

Duo S 730 4167394 16/16 D 52; P 37 30 70 Nitinol Seldinger needle n n Safsite® Valve

Duo V 730 4161319 16/16 D 52; P 37 30 70 Nitinol Valve needle n n Safsite® Valve

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG- Mini Valve /
(REF) øG (ml/min) * (cm) Length Seldinger needle Cable Scalpel Plug
Material
(cm)
Trio S 715 4161159 16/18/18 D 50; M1 28; P 28 15 50 Nitinol Seldinger needle n n Safsite® Valve

Trio V 715 4162153 16/18/18 D 50; M1 28; P 28 15 50 Nitinol Valve needle n n Safsite® Valve

Trio S 720 4167408 16/18/18 D 46; M1 22; P 22 20 50 Nitinol Seldinger needle n n Safsite® Valve

Trio V 720 4163214 16/18/18 D 46; M1 22; P 22 20 50 Nitinol Valve needle n n Safsite® Valve

Trio S 730 4163306 16/18/18 D 38; M1 18; P 18 30 70 Nitinol Seldinger needle n n Safsite® Valve

Trio V 730 4163311 16/18/18 D 38; M1 18; P 18 30 70 Nitinol Valve needle n n Safsite® Valve

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
n The sales unit of Certofix® Duo and Trio Sets is 10 pcs.

n All catheters are made of PUR

7
Certofix® Quattro / Certofix® Quinto

Product Type Code No. Cath. Lumen ø G Flow rate Length Guide wire Valve needle/
(REF) (ml/min) * (cm) Length (cm) Seldinger needle

Quattro V 815 4167767 14/18/18/16 D 50; M1 20; M2 20; P 50 15 50 Valve needle

Quattro V 820 4167775 14/18/18/16 D 40; M1 15; M2 15; P 40 20 50 Valve needle

Quattro V 830 4167783 14/18/18/16 D 35; M1 10; M2 10; P 35 30 70 Valve needle

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/
(REF) øG (ml/min) * (cm) Length (cm) Seldinger needle

Quinto V 1215 4166841 16/18/18/18/12 D 65; M1 32; M2 32; M3 30; P 225 15 50 Valve needle

Quinto S 1220 4166852 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50 Seldinger needle

Quinto V 1220 4166868 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50 Valve needle

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
n The sales unit of Certofix® Quattro and Quinto Sets is 10 pcs.

n All sets include:

- an ECG lead cable


- a kink-proof guide wire made of Nitinol
- a Mini scalpel
n All sets are available with Safsite® Valve

n All catheters are made of PUR

8
Certofix® Highflow / Certofix® Accessories

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/
(REF) øG (ml/min) * (cm) length (cm) Seldinger needle

Duo HF V 715 4168518 14/18 D 105; P 42 15 50 Valve needle

Duo HF V 1215 4167538 11/11 D 260; P 260 15 50 Valve needle

Duo HF S 720 4168528 14/18 D 100; P 27 20 50 Seldinger needle

Duo HF V 720 4168534 14/18 D 100; P 27 20 50 Valve needle

Duo HF V 920 4167511 13/13 D 95; P 120 20 50 Valve needle

Duo HF V 1220 4167546 11/11 D 230; P 230 20 50 Valve needle

Trio HF S 1215 4160578 16/12/12 D 65; M1 225; P 225 15 50 Seldinger needle

Trio HF V 1215 4160614 16/12/12 D 65; M1 225; P 225 15 50 Valve needle

Trio HF S 1220 4160586 16/12/12 D 55; M1 165; P 165 20 50 Seldinger needle

Trio HF V 1220 4160622 16/12/12 D 55; M1 165; P 165 20 50 Valve needle

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
n The sales unit of Certofix® Highflow Sets is 10 pcs.

n All sets include:

- an ECG lead cable


- a kink-proof guide wire made of Nitinol
- a Mini scalpel
n All sets are available with Safsite® Valve

n All catheters are made of PUR

Product Type Code No. (REF) Description


Certodyn® Universal Adapter 4150228 Electronic switch box (for adults)

Certodyn® Universal Adapter Paed 4150724 Electronic switch box (for paediatrics)

Alphacard® U1800401 Syringe with electrode cable to universal adapter

9
Certofix® Econoline

CVC for your basic needs


Certofix® basic catheter sets combine high quality with user
appreciated components. All components included in the
Certofix® Basic Sets like the dilator, the Seldinger guide-wire
and the entire catheter are designed for excellent performance.
Certofix® Econoline sets assure the user to have state-of-the-art
equipment in his or her hand.

Mono Duo Trio IN-Stopper


B. Braun IN-Stoppers are
easy and convenient in
handling, provide close
proximal needle-free injection sites
and offer a needle access
middle
via the integrated latex-free
proximal
membrane.
distal distal

User benefits Product specifications


Soft catheter quality avoids venous irritations
„„ Radio-opaque polyurethane catheter, with soft
CVC insertion – the safety approach
„„ tip, length markings, either with movable fixation
- IN-Stoppers device or junction hub for stitch fixation and fully
- Kink-resistant catheter material transparent extension lines on multilume catheters,
- Catheter Soft Tip with color-coded hub and white slide clamps.
Components: Steel guide wire with “J” tip on
Avoid drug incompatibility
„„
dispenser, movable fixation wing, with clamp,
- multi-lumen catheters up to 3 connection lines
Seldinger needle, In-Stopper
Rigid packaging for fast preparation and
„„

convenient storage

10
Certofix® Econoline

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve needle/ ECG- Valve /
(REF) øG (ml/min) * (cm) Length Seldinger needle Cable Plug
Material
(cm)
Mono 215 Econoline 4160185E 18 D 16 15 50 Steel Seldinger needle - IN-Stopper

Mono 315 Econoline 4160223E 16 D 55 15 50 Steel Seldinger needle - IN-Stopper

Mono 415 Econoline 4160509E 14 D 95 15 50 Steel Seldinger needle - IN-Stopper

Mono 220 Econoline 4160207E 18 D 13 20 50 Steel Seldinger needle - IN-Stopper

Mono 320 Econoline 4160258E 16 D 45 20 50 Steel Seldinger needle - IN-Stopper

Mono 420 Econoline 4160304E 14 D 85 20 50 Steel Seldinger needle - IN-Stopper

Mono 330 Econoline 4160282E 16 D 40 30 70 Steel Seldinger needle - IN-Stopper

Mono 430 Econoline 4160762E 14 D 75 30 70 Steel Seldinger needle - IN-Stopper

Duo 715 Econoline 4164156E 16/16 D 60; P 50 15 50 Steel Seldinger needle - IN-Stopper

Duo 720 Econoline 4162200E 16/16 D 55; P 45 20 50 Steel Seldinger needle - IN-Stopper

Duo 730 Econoline 4162307E 16/16 D 52; P 37 20 70 Steel Seldinger needle - IN-Stopper

Trio 715 Econoline 4161157E 16/18/18 D 50; M1 28; P 28 15 50 Steel Seldinger needle - IN-Stopper

Trio 720 Econoline 4163206E 16/18/18 D 46; M1 22; P 22 20 50 Steel Seldinger needle - IN-Stopper

Trio 730 Econoline 4163303E 16/18/18 D 38; M1 18; P 18 30 70 Steel Seldinger needle - IN-Stopper

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
n The sales unit of Certofix® Econoline Sets is 10 pcs.

n All catheters are made of PUR

11
Certofix®

Anti-pathogenic Certofix® catheter The principles of Certofix® protect


A patented combination of an anti-microbial agent (Polyhexanide) The Polarization of Certofix® protect catheter material destroys
and a-thrombogenic chemical group (Polyethylene glycol and the cell wall structure of microorganisms in case of surface
Polymethacrylate) creates a highly effective catheter surface. contact. Perpetual chemical interaction between the catheter
The adhesion of bacteria which is normaly the starting point material (PUR) and the agent Biguanide ensures long-term
of a catheter-related bloodstream infection is effectivly pre- protection without leaching effect. Certofix® protect prevents
vented. A high concentration of hydrophilic groups lowers the from catheter-related infections during the entire application
risk of thrombus aggregation on the catheter surface. of the catheter.

Interaction of a
microorganism with
the catheter surface

Efficacy spectrum
„ Gram-positive bacteria (St. aureus, St. epidermidis)

„ MRSA (methicillin-resistant Staphylococcus aureus)

„ Gram-negative bacteria, e. g. Pseudimonas aeruginosa, Escherichia coli


coated vs. control (%)
Antibacterial efficiacy

Days

Long-term protection
Even after weeks, the Certofix® protect catheter material exhibits an
effective level of protection against catheter colonization. After 30 days,
Certofix® protect still shows an efficacy of 75%.

User benefits Product specifications


No active agents are released, thereby
„„ Radio-opaque polyurethane catheter with
avoiding adverse systemic reactions anti-bacterial and -thrombogenic surface
Hydrophilic catheter surface for proven
„„ modification inside the lumen and the outside
reduction in thrombosis formation surface; catheter with soft tip, length markings,
junction hub for stitch fixation and fully trans-
The same excellent flexibility as other
„„
parent extension lines, with color-coded hub
Certofix® catheters
and green slide clamp.
Total catheter surface coverage – from tip
„„
Components: see next page (Product Specifications)
to hub, on the inner and outer surface available with valve introducer needle.

12
Product Type Code No. Cath. Lumen Flow rate Length Guide wire Mini Valve /
(REF) øG (ml/min) * (cm) Length (cm) Scalpel Plug

Mono V 320 Protect 4160266P 16 D 52 20 50 - -

Mono V 420 Protect 4160320P 14 D 80 20 50 - -

Mono V 330 Protect 4160290P 16 D 40 30 70 - -

Mono V 430 Protect 4160789P 14 D 75 30 70 - -

Duo V 715 Protect 4166159 P 16/16 D 60; P 50 15 50 n Safsite® Valve

Duo V 720 Protect 4161211P 16/16 D 55; P 45 20 50 n Safsite® Valve

Duo V 730 Protect 4161319 P 16/16 D 52; P 37 30 70 n Safsite® Valve


Duo HF V 720
4168534P 14/18 D 100; P 27 20 50 n Safsite® Valve
Protect
Trio V 715 Protect 4162153 P 16/18/18 D 50; M1 28; P 28 15 50 n Safsite® Valve

Trio V 720 Protect 4163214P 16/18/18 D 46; M1 22; P 22 20 50 n Safsite® Valve

Trio V 730 Protect 4163311 P 16/18/18 D 38; M1 18; P 18 30 70 n Safsite® Valve

Trio HF V 1220 Protect 4160622P 16/12/12 D 55; M1 165; P 165 20 50 n Safsite® Valve

Quattro V 815 Protect 4167767P 14/18/18/16 D 50; M1 20; M2 20; P 50 15 50 n Safsite® Valve

Quattro V 820 Protect 4167775P 14/18/18/16 D 40; M1 15; M2 15; P 40 20 50 n Safsite® Valve

Quattro V 830 Protect 4167783P 14/18/18/16 D 35; M1 10; M2 10; P 35 30 70 n Safsite® Valve

Quinto V 1220 Protect 4166868P 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50 n Safsite® Valve

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

The base material of the central venous catheter Certofix® protect consists of polyurethane (PUR). All lumens, including the hub and
the outer surface of the catheter, are coated with a long-chain polymer based on methacrylat. Catheters contain hydrophilic side
groups such as polyethylene glycol and antiseptic polymeric biguanide side groups.

Additional information:
n The sales unit of Certofix® protect Sets is 10 pcs.

n All sets include:

- an ECG lead cable


- a kink-proof guide wire made of Nitinol
n All sets are available with Valve needle

n All catheters are made of PUR + Biguanide

13
Certofix® Paed
... for children´s safety

Getting it right for the little ones


B. Braun´s long-term experience and global expertise are
reflected in the paediatric range of central venous catheters.
Uncompromising quality and modern features to fit the
special requirements of infants and children.

User benefits Product specifications


Safe and ceffective positioning
„„ Radio-opaque polyurethane catheter with soft
- Kink-proof guide wire tip, length markings, junction hub for stitch
- Real-time ECG-lead position verification fixation and fully transparent extension lines,
Gentle to vulnerable patients
„„ with color-coded hub and white slide clamps.
- Teddy Bear catheter fixation makes Components: Kink-proof guide wire with “J” tip
stitching superfluous and straight tip on dispenser, movable fixation
- Kink-proof guide wire avoids any damage wing with clamp, Seldinger introducer needle,
of the sensitive intima scalpel, dilator, ECG-lead cable, Safsite® valve,
5 ml Omnifix® luer lock syringe

14
Kink-proof guide wire Teddy Bear fixation Introducer guide for guide wire
„ Extreme flexible and resilient guide wire „ Safe and easy catheter fixation without stich „ Improves threading of the “J” tip of the
made of Nitinol „ Soft to the skin of babies and newborns guide wire into the Seldinger needle
„ Guide wire with the right stiffness for „ Gentle removing possible „ Allows dispenser-free advancing of the

easy advancing guide wire through the introducer

Product Type Code No. Cath. Lumen Flow rate Length Guide wire Valve /
(REF) øG (ml/min) * (cm) ø / Length (cm) Plug

Mono Paed S 110* 4160177 22 D 15 10 0,5/25 –

Duo Paed S 408 4166906 22/22 D 18; P 18 8 0,46/50 Safsite® Valve

Duo Paed S 413 4166922 22/22 D 10; P 10 13 0,46/50 Safsite® Valve

Duo Paed S 420 4166949 22/22 D 9; P 9 20 0,46/50 Safsite® Valve

Duo Paed S 508 4167112 18/20 D 30; P 15 8 0,46/50 Safsite® Valve

Duo Paed S 513 4167139 18/20 D 22; P 11 13 0,46/50 Safsite® Valve

Duo Paed S 520 4167155 18/20 D 18; P 9 20 0,46/50 Safsite® Valve

Trio Paed S 508 4167228 20/22/22 D 30; M1 15; P 15 8 0,46/50 Safsite® Valve

Trio Paed S 513 4167244 20/22/22 D 29; M1 10; P 10 13 0,46/50 Safsite® Valve

Trio Paed S 520 4167260 20/22/22 D 18; M1 6; P 6 20 0,46/50 Safsite® Valve

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
„ The sales unit of Certofix® Paed Sets is 10 pcs.

„ All sets include:

- an ECG lead cable


- a kink-proof guide wire made of Nitinol
- a Mini scalpel
„ All sets are available:

- with Seldinger needle


- with Statlock-Fixation
„ All catheters are made of PUR

15
Certofix® Safety
Increased safety for users

A broad variety of puncture needles and scalpels for incisions The Seldinger puncture needle has an active safety mechanism.
are used. The operating space and sterility during catheter The safety clip surrounds the needle tip as soon as it is deployed,
application often complicates the immediate disposal of sharp so medical personnel is well protected during operation
instruments. and disposal. It is possible to activate the clip, while the
With Certofix® Safety, B. Braun is enhancing the product cannula is guided over the guide wire.
portfolio for safe venous access.

During application, the plastic housing with safety clip is located next to
the needle hub. Once the guide wire has been placed in its desired position,
the safety clip, covered by the hub has to be forwarded onto skin level.
While simultaneously activating the safety mechanism, the needle is
withdrawn with the index finger.

After the protecting cover has been removed, the scalpel is moved forward
with the help of the green button until it snaps in and pushed back after
the incision.

User benefits
Small design of safety mechanism does not
„„

affect application procedure of central venous


catheters
All components needed for safe catheters
„„

placement included for puncture and incision –


a safety Seldinger needle as well as a scalpel
with sharps protection mechanism

16
Seldinger Needle Safety
Puncture needle with active safety mechanism to protect
against needle stick injuries. The integrated clip does not affect
puncturing procedure and can be activated single-handedly.

2 3

When the tip of the needle is reached, the safety clip activates automatically Once the needle has been completely pulled back behind the wire, the safety
and covers the needle tip already. clip envelopes the tip irreversibly.The needle and the plastic hub can now be
disposed in the usual way.

II III

Latching-mechanism
appears in the window.

Before the blade is finally secured, the scalpel can be held in a „parking position“ Once the blade has been withdrawn to the hilt/to the end of the press-button
enabling it to be handed over to other medical personnel. function, the safety mechanism activates. The scalpel is safe to be discarded.

Scalpel Safety
Stable, easy-to-use safety scalpel with safety mechanism
for the securing of the blade after incision.

17
Certofix® Safety

Product Type Code No. Cath. Lumen Flow rate Length Guide wire
(REF) øG (ml/min) * (cm) Length (cm)

Mono S 320 Safety 4160258S 16 D 52 20 50

Mono S 330 Safety 4160282S 16 D 40 30 70

Duo S 720 Safety 4167385S 16/16 D 55; P 45 20 50

Duo S 730 Safety 4167394S 16/16 D 52; P 37 30 70

Trio S 720 Safety 4167408S 16/18/18 D 46; M1 22; P 22 20 50

Trio S 730 Safety 4163306S 16/18/18 D 38; M1 18; P 18 30 70

Quattro S 820 Safety 4167775S 14/18/18/16 D 40; M1 15; M2 15; P 40 20 50

Quinto S 1220 Safety 4166852S 16/18/18/18/12 D 55; M1 28; M2 28; M3 28; P 185 20 50

* D (distal); M1 (middle1); M2 (middle2); M3 (middle3); P (proximal)

Additional information:
n The sales unit of Certofix® Safety Sets is 10 pcs.

n All sets include:

- an ECG lead cable


- a kink-proof guide wire made of Nitinol
- a safety scalpel
n All sets are available:

- with Seldinger Safety needle


- with Safsite® Valve
n All catheters are made of PUR

18
Notes

19
B. Braun Melsungen AG | Hospital Care | 34209 Melsungen | Germany
Tel +49 56 61 71-0 | www.bbraun.com

You might also like