ROSA Detailed Report Page 1 of 3

Reverse Osmosis System Analysis for FILMTEC™ Membranes ROSA 9.1 ConfigDB u399339_282
Project: 180306_TERSAN Case: 1
TERSAN, MFT 3/6/2018

Project Information: Simmulation for CD-Modul

Case-specific:

System Details

Feed Flow to Stage 1 8.00 m³/h Pass 1 Permeate Flow 2.40 m³/h Osmotic Pressure:
Raw Water Flow to System 3.00 m³/h Pass 1 Recovery 80.00 % Feed 3.42 bar
Feed Pressure 36.38 bar Feed Temperature 15.0 C Concentrate 16.53 bar
Flow Factor 0.85 Feed TDS 5529.85 mg/l Average 9.98 bar
Chem. Dose (100% H2SO4) 0.00 mg/l Number of Elements 3 Average NDP 21.66 bar
Total Active Area 111.48 M² Average Pass 1 Flux 21.53 lmh Power 10.11 kW
Water Classification: Wastewater with Conventional pretreatment, SDI < 5 Specific Energy 4.21 kWh/m³

Feed Feed Recirc Conc Conc Perm Avg Perm Boost Perm
Stage Element #PV #Ele Flow Press Flow Flow Press Flow Flux Press Press TDS
(m³/h) (bar) (m³/h) (m³/h) (bar) (m³/h) (lmh) (bar) (bar) (mg/l)
1 SW30XLE-400i 1 3 8.00 36.03 5.00 5.60 35.33 2.40 21.53 0.00 0.00 57.49

Pass Streams
(mg/l as Ion)
Adjusted Feed Concentrate Permeate
Name Feed
Initial After Recycles Stage 1 Stage 1 Total
NH4+ + NH3 317.73 318.00 1098.34 1566.48 6.90 6.90
K 604.00 604.00 2101.51 2999.74 5.61 5.61
Na 909.00 909.00 3164.80 4517.96 7.39 7.39
Mg 136.00 136.00 475.06 678.48 0.40 0.40
Ca 14.00 14.00 48.91 69.85 0.04 0.04
Sr 0.00 0.00 0.00 0.00 0.00 0.00
Ba 0.00 0.00 0.00 0.00 0.00 0.00
CO3 0.42 0.42 9.91 25.33 0.00 0.00
HCO3 943.00 943.00 3251.40 4616.07 14.88 14.88
NO3 2.50 2.50 8.31 11.79 0.20 0.20
Cl 878.00 1958.93 6806.81 9714.44 22.23 22.23
F 10.00 10.00 34.76 49.62 0.10 0.10
SO4 634.00 634.00 2218.84 3169.76 0.00 0.00
SiO2 0.00 0.00 0.00 0.00 0.00 0.00
Boron 0.00 0.00 0.00 0.00 0.00 0.00
CO2 332.33 332.33 333.23 340.69 334.49 334.43
TDS 4448.65 5529.85 19218.66 27419.26 57.49 57.49
pH 6.50 6.50 6.88 6.97 4.90 4.90

*Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS GIVEN. Neither FilmTec Corporation nor The Dow Chemical
Company assume any obligation or liability for results obtained or damages incurred from the application of this information. Because use conditions and applicable
laws may differ from one location to another and may change with time, customer is responsible for determining whether products are appropriate for customer’s use.
FilmTec Corporation and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design software, the customer
should be sued for alleged infringement of any patent not owned or controlled by the FilmTec Corporation nor The Dow Chemical Company.

file:///C:/Program%20Files%20(x86)/Dow%20Chemical/ROSA9/MyProjects/180306... 06.03.2018
ROSA Detailed Report Page 2 of 3

Reverse Osmosis System Analysis for FILMTEC™ Membranes ROSA 9.1 ConfigDB u399339_282
Project: 180306_TERSAN Case: 1
TERSAN, MFT 3/6/2018

Design Warnings

-None-

Solubility Warnings

Langelier Saturation Index > 0


CaF2 (% Saturation) > 100%
Antiscalants may be required. Consult your antiscalant manufacturer for dosing and maximum allowable system recovery.

Stage Details

Stage 1 Element Recovery Perm Flow (m³/h) Perm TDS (mg/l) Feed Flow (m³/h) Feed TDS (mg/l) Feed Press (bar)
1 0.11 0.88 46.71 8.00 19218.66 36.03
2 0.11 0.80 57.13 7.12 21593.50 35.76
3 0.11 0.72 71.25 6.32 24325.65 35.52

Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS GIVEN. Neither FilmTec Corporation nor The Dow Chemical
Company assume any obligation or liability for results obtained or damages incurred from the application of this information. Because use conditions and applicable
laws may differ from one location to another and may change with time, customer is responsible for determining whether products are appropriate for customer’s use.
FilmTec Corporation and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design software, the customer
should be sued for alleged infringement of any patent not owned or controlled by the FilmTec Corporation nor The Dow Chemical Company.

file:///C:/Program%20Files%20(x86)/Dow%20Chemical/ROSA9/MyProjects/180306... 06.03.2018
ROSA Detailed Report Page 3 of 3

Scaling Calculations

Raw Water Adjusted Feed Concentrate


pH 6.50 6.50 6.97
Langelier Saturation Index -1.26 -1.26 0.56
Stiff & Davis Stability Index -1.38 -1.38 -0.25
Ionic Strength (Molal) 0.08 0.10 0.50
TDS (mg/l) 4448.65 5529.85 27419.26
HCO3 943.00 943.00 4616.07
CO2 332.30 332.30 340.58
CO3 0.42 0.42 25.33
CaSO4 (% Saturation) 0.89 0.89 5.36
BaSO4 (% Saturation) 0.00 0.00 0.00
SrSO4 (% Saturation) 0.00 0.00 0.00
CaF2 (% Saturation) 186.11 186.11 22860.29
SiO2 (% Saturation) 0.00 0.00 0.00
Mg(OH)2 (% Saturation) 0.00 0.00 0.00

To balance: 1080.93 mg/l Cl added to feed.