You are on page 1of 447

Tender No.

029 / 17

Construction Completion, Testing and Commissioning including Remedying all Defects of


Intercontinental Resort Hotel in Mina Al Arab, Ras Al Khaimah, United Arab Emirates.

Tender No. 029 / 17

Construction, Completion, Commissioning and


Testing including Remedying All Defects of

Intercontinental Resort Hotel


Mina Al Arab, Ras Al Khaimah
United Arab Emirates

-------------------------------------------------------------------------------------------------------------
TENDER DOCUMENTS FOR
MAIN CONTRACT WORKS
-------------------------------------------------------------

Volume 2
Bills of Quantities including Preambles

Addendum 01

Volume 2 Bills of Quantities September 2017


REV 01
CONTENTS

GRAND SUMMARY
PREAMBLES
BILL 1 - GENERAL REQUIREMENT
BILL 2 - MAIN HOTEL
BILL 3 - VILLAS & CHALETS
BILL 4 - SEAFOOD RESTAURANT
BILL 5 - MECHANICAL/ELECTRICAL & PLUMBING
BILL 6 - LANDSCAPING
BILL 7 - PROVISIONAL SUMS
BILL 8 - DAY WORKS

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
BILLS OF QUANTITIES

GRAND SUMMARY

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties

Amount AED

GRAND SUMMARY Page No.

BILL NO

1 General Requirements Bill No.1 Page 25

2 Main Hotel Bill No.2 Page 75

3 Villas and Chalets Bill No.3 Page 15

4 Seafood Restaurant Bill No.4 Page 18

5 Mechanical/Electrical & Plumbing Bill No.5 Page 175

6 Landscaping Bill No.6 Page 93

7 Provisional Sums Bill No.7 Page 1

8 Day Works Bill No.8 Page 6

TOTAL CARRIED TO FORM OF TENDER:


PREAMBLES
MAIN CONTRACT
INTERCONTINENTAL RESORT HOTEL
RAK PROPERTIES

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
BILLS OF QUANTITIES – PRICING PREAMBLES

Contents

PRICING PREAMBLES ........................................................................................................................... 2


GENERALLY .......................................................................................................................................... 2
METHOD OF MEASUREMENT .............................................................................................................. 3
PRICING................................................................................................................................................ 3
DEFINITIONS ........................................................................................................................................ 4
DIVISION 1 - GENERAL REQUIREMENTS .............................................................................................. 9
DIVISION 2 - SITE CONSTRUCTION .................................................................................................... 10
DIVISION 3 - CONCRETE ..................................................................................................................... 11
DIVISION 4 - MASONRY ..................................................................................................................... 13
DIVISION 5 - METALS ......................................................................................................................... 14
DIVISION 6 – WOODS AND PLASTICS ................................................................................................ 14
DIVISION 7 - THERMAL AND MOISTURE CONTROL ........................................................................... 15
DIVISION 8 – DOORS AND WINDOWS ............................................................................................... 15
DIVISION 9 - FINISHES ........................................................................................................................ 16
DIVISION 10 - SPECIALITIES................................................................................................................ 17
DIVISION 11 - EQUIPMENT ................................................................................................................ 17
DIVISION 12 - FURNISHINGS .............................................................................................................. 17
DIVISION 13 – SPECIAL CONSTRUCTION ........................................................................................... 17
DIVISION 14 – CONVEYING SYSTEMS ................................................................................................ 17
DIVISION 15 - MECHANICAL ENGINEERING INSTALLATIONS ............................................................ 17
DIVISION 16 - ELECTRICAL ENGINEERING INSTALLATIONS ............................................................... 18
SERVICES GENERALLY ........................................................................................................................ 21
BUILDER’S WORK ............................................................................................................................... 21

Page 1 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

PRICING PREAMBLES
A. The Works herein are to be read in conjunction with the Specifications and Drawings. The scope
of work comprises the Works as defined and scheduled within the composite Contract
Documents and the Drawings, Specifications, Conditions of Contract and the Bills of Quantities
together with all other Contract Documents are complementary and items included in any one
document shall be deemed included in all.

B. The Contract Price for the Works is deemed to be lump sum. The Contractor will be responsible
for close liaison with the Engineer to ensure accurate records are kept to verify any changes to
the Works measured within this document.

C. The various documents collectively referred to herein as the Bills of Quantities jointly constitute
the Bill of Quantities referred to in the Conditions of Contract.

D. Upon award of Contract, the Bills of Quantities shall be used purely as a mechanism for
evaluation of progress payments due to the Contractor, and as a Schedule of Rates for valuation
of variations.

GENERALLY
A. The Bills of Quantities herein, including all notes and instructions, shall form an integral part of
the Tender and Contract Documents. However, the descriptions contained in the Bills of
Quantities for each item are not necessarily complete. The Tenderer is referred to the
Conditions of Contract and other documents, Specifications and Drawings as well as all relevant
applicable Standards and Codes of Practice for further information; as no claim or variation will
be considered on an account of the Contractor's failure to do so.

B. The Contractor is deemed to have allowed against the items or in the prices contained in these
Bills of Quantities for everything within the scope of the Works that has a monetary value.

C. The Contractor should note that the full content of other Documents including the Drawings
and Specifications or any other information that can be reasonably inferred from any of them
and all obligations contained in the documents is deemed included in the Contract Rates and
lump sum Contract Price, even if specific items relating to them are not listed in the Bills of
Quantities.

D. Amendments shall not be made to these Bills of Quantities without the authority, in writing, of
the Engineer.

E. The Contract Price for the Works shall be deemed to provide for attendance and supervision of
any or all trades that is not intended to be performed with the Contractor’s own forces.

F. The Contractor shall not use these Bills of Quantities as the basis for a construction programme
or for the purpose of ordering materials or arranging sub-contracts, be they nominated or
otherwise. The references for these activities shall be the drawings, specifications and
instructions issued by the Engineer.

Page 2 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

Format of Descriptions

In addition to common abbreviations the following have been adopted:


CSI Construction Standards Institute Master Format
Millimetre mm
Metre m
m² - Square Metre m², m2, sq.m
Cubic Meter m³, m3, cu.m
Number nr, Nr, No.
Kilograms kg
Kilo Newton KN
Composite Item item, Item
Hour hr, Hr
Days Day
Weeks wk, Wk

METHOD OF MEASUREMENT
A. These Bills of Quantities have been measured in accordance with the Rules of CSI (as here below
defined) and rates shall include for everything required for complete sections of work in
accordance with the Specifications and Drawings unless CSI demands the measurement of
additional items. In any case in the Bills of Quantities where the method differs then the method
expressed must be accepted and measured in accordance therewith. Notwithstanding the
above the following pricing preambles are offered only as an amplification or clarification to
billed description.

B. Items in the Preambles Section of these Bills of Quantities are deemed to qualify and to form
part of every description of measured work to which they refer including composite
descriptions.

C. All measurements are net and the rates shall include for all laps, waste, working space and trade
or traditional allowances.

PRICING
A. Unless otherwise stated all item descriptions in these Bills of Quantities shall be priced on the
basis of the supply and installation (and connection where necessary) of the complete system
in accordance with the Specifications and Drawings.

B. The prices and rates shall be comprehensive and must include for complying in all respects with
the Bill of Quantities, Instruction to Tenderers, General Conditions of Contract, Particular
Conditions of Contract, Specifications and Drawings and for all matters and things necessary for
the proper construction, completion, and maintenance of the whole of the Works. No claims
for additional payment will be allowed for any error or misunderstanding by the Contractor of
the work involved.

C. The Tenderer's unit rates are to be fully inclusive value of the work described and must include
all related work, accessory or consumable materials, incidental labour, administration, tools,
equipment, overhead and profit and all costs and expenses which may be required in and for

Page 3 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

completion of the work described together with all costs and expenses in complying with all
general risks, liabilities and obligations set forth or implied in the Drawings, Specifications and
Conditions of Contract.

D. Items where unit rates are applicable should be priced fully and should if possible not be
denoted as 'included' or 'lump sum' item.

E. Where the word "allow" is used, the cost of the items shall be the responsibility of the
Contractor.

F. Where the word "item" is used, the cost of the items shall be the responsibility of the
Contractor.

G. The amounts set against any items of profit shall include for all costs in connection with the
letters of credit, bonds/warranties, bank charges, interest charges and insurance after the
materials come under the control of the Contractor.

H. No variation will be allowed for any error in the computation of the Tender discovered after
date of issue of letter of acceptance of the tender and award of the Contract.

DEFINITIONS
A. "Falls", "Slopes", "Weathered: inclined from the horizontal in one plane

B. "Cross Falls", "Cross Slopes", "Cross Weathered": inclination from the horizontal in more than
one plane.

C. "Remove" means disconnect, dismantle as necessary and remove the stated element, work or
component and all associated accessories, fastenings, supports, linings and bedding materials,
and dispose of unwanted materials. It does not include removing associated pipework, wiring,
ductwork or other services.

D. "Keep for re use" means: During removal prevent damage to the stated components or
materials, and clean off bedding and jointing materials. Stack neatly, adequately protect and
store until required by the Employer or for use in the Works as instructed.

E. "Replace" means: Remove the stated existing components, features and finishes. Provide and
fit in lieu new components, features or finishes which, unless specified otherwise, must
match those which have been removed. Make good as necessary.

F. "Repair" means carry out local remedial work to components, features and finishes as found in
the existing building. Re-secure or re-fix as necessary and leave in a sound and neat condition.
It does not include: Replacement of components or parts of components.

G. "Ease" means make minor adjustments to moving parts of the stated component to achieve
good fit in both open and closed positions and ensure free movement in relation to fixed
surrounds. Make good as necessary.

Page 4 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

H. "To match existing means use products, materials and methods to match closely all visual
characteristics and features of the existing work, with joints between existing and new work as
inconspicuous as possible

Install Only

I. The expression "install only" used in the Bills of Quantities means that the Contractor shall
provide the following facilities only and that all other costs incidental to the item in question
will be borne by the Employer:
(1) Unloading, storing, distributing and hoisting goods and materials.
(2) Supplying full size templates.
(3) Giving and marking dimensions and taking responsibility for their accuracy.
(4) Getting in, protecting, handling, distributing and placing in position.
(5) Assembling as required.
(6) Casing up and protection, including clearing away protection on completion of the
works.
(7) Full cost of replacement of any items which are damaged, broken, lost or stolen
after the acceptance of
(8) Other necessary and usual facilities and documentation.

Supply Only

J. The expression "supply only" used in the Bills of Quantities means that the Contractor is to
include for all liabilities and obligations arising out of the Contract except fixing in position.

Sub-Contractors

K. Any direct Sub-contractors which the Contractor proposes to use for the works are subject to
the approval of the Engineer and Employer.

L. The Contractor shall provide a list of Sub-contractors who will be employed on the works for
approval by the Engineer.

M. If the Contractor is refused permission to use any of his proposed Sub-contractors then the work
shall be sub-let at no extra cost to an approved Sub-contractor.

N. Any Sub-contractor who has not been approved by the Employer shall not be used in connection
with the carrying out of the works.

O. The Contractor should ascertain from Sub-contractors and suppliers before the work is put in
hand particulars of positions in which chases, holes, mortices and the like will be required to be
formed or left. No claim for the extra costs of cutting away work already built due to the
contractor's failure to ascertain these particulars will be admitted.

P. The Contractor should ascertain from all Sub-contractors and Suppliers before the work is put
in hand particular of positions in which chases, holes, mortises and the like will be required to
be formed or left. No claim for the extra costs of cutting away work already built due to the
Contractor's failure to ascertain these particulars will be admitted.

Page 5 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

Q. The Contractor shall allow for any additional costs incurred due to Sub-contractors working
different hours from and extended hours to those worked by the Contractor.

R. The Contractor shall be responsible for providing, including but not limited to, the following
attendances:
(1) Use of Contractor's administrative arrangements.
(2) Use of Constructional Plant.
(3) Use of Contractor's mess room, sanitary and welfare facilities.
(4) Co-ordination and scheduling of all works related to each Sub-contract and
nominated Sub-contract.
(5) Use of standing scaffolding
(6) Use of temporary works including water and electricity.
(7) Supplying full size setting out templates.
(8) Giving and marking dimensions and taking responsibility for their accuracy.
(9) Space for Sub-contractor stores.
(10) Providing work space
(11) Offloading Sub-contractors' or suppliers' materials and placing in stores.
(12) Clearing away all and any rubbish be it generated by Contractor, nominated or
direct subcontractors.
(13) Other necessary and usual facilities, documentation, general intergrades
attendances, labour and assistance.

S. The Sub-contractor or nominated Sub-contractor shall be responsible for providing, including


but not limited to, the following attendances:
(1) All special scaffolding required by them in the execution of their works.
(2) Taking from stores, distributing, hoisting and placing in position, all items of plant,
equipment and materials required by them in the execution of their works.
(3) All labour, plant etc. (other than included in Attendances to be provided by the Main
Contractor).
(4) Site offices and stores required by them for the execution of their works.
(5) Offloading

Provisional Sums

A. For all work executed, or goods, materials, plant or services the Contractor shall be entitled to:-
(1) The actual price paid or due to be paid by the Contractor, on the instructions of the
Engineer.

B. The following costs are deemed to be excluded from the Provisional Sum allowance:-
(1) Main Contractors overhead and profit
(2) Main Contractors general and special attendances
(3) Main Contractors builders work in connection

C. Mechanism for instruction and payment against Provisional Sum allowances:-


(1) The Employer or Employer's representative may initially instruct the Contractor to
carry out the design only element associated with the Provisional Sum prior to
approval of the main construction works. It is accepted that the design fee
percentage covers to design the particular Provisional Sum once and should the

Page 6 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

design be revised by choice of the Employer, any subsequent re-design / re-work


will be paid on the daywork rates for professional design services included within
thin the contract.
(2) In respect of all other contractors charges including; builders-work, overhead,
profit and attendance the Contractor shall insert separately the percentage or sum
as applicable required for all other charges against each item in the Bill of
Provisional Sums.
(3) Should work stated as a Provisional Sum be entirely deleted from the Contract by
the Engineer, the allowance for overhead and profit, special attendances and
builders work will be deleted accordingly as a variation in accordance with the
Terms of the Contract.

PC Supply Only rates in description contained in the Bills of Quantities

A. PC rates of Supply Only rates for suppliers of materials and equipment shall be deemed to
include delivery to site and exclude the Main Contractor's percentage for overheads and profit
as stated in the Preliminaries section of the Bills of Quantities.

At the time the Engineer has approved the actual material to be used in the Works, the actual
delivered to site costs plus Contractor's overhead and profit percentage as stated in the Bills of
Quantities shall be inserted into the Contractor' rate following the deduction of the original PC
Supply Only rate contained in the Contractor's rates against the particular item description in
the Bills of Quantities.

B. The Contractor when pricing items in the Bills of Quantities which contain PC supply only rates
shall add to the PC rate the amounts required to cover for profit and overheads, unloading from
delivery vehicle to site store, loading and transporting from site store, hoisting and lowering and
distribution to various positions, assembly as necessary, fixing, casing up, protecting and finally
cleaning down and, where appropriate, oiling and adjusting and leaving in perfect order, all
necessary straight, cured and irregular cutting, wastage and all other allowances required to
fully fix, install or place the fixed and will not be adjusted against the final value of the supply
rates adopted. Should the item including PC Supply Only rates be deleted by the Engineer from
the Contract, no payment against that item will be made to the Contractor.

C. The Employer shall select the Supplier from those listed in either the contract specifications or
from a list proposed by the Contractor or designers and the Contractor shall be responsible for
procurement of the materials. The Contractor shall arrange for all co-ordination of deliveries be
they in part or full loads to suit the Contractor's Programme of Works.

General and Special Attendances

A. The expression General Attendances shall mean that the Contractor shall provide attendances
and facilities including, but not limited to, the following:
(1) Assistance as defined/identified in CSI including electricity and water.
(2) The use of the Contractor's administrative facilities.
(3) The use of general construction plant.
(4) The use of the Contractor's facilities, including mess rooms, sanitary
accommodation and welfare facilities.
(5) The use of temporary works
(6) Space for Sub-contractor’s stores and lay down areas.
(7) The clearing away of all rubbish, waste and debris on a regular basis.

Page 7 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

(8) Use of standing scaffolding / general scaffolding.


(9) Unloading, distributing, hoisting or lowering to the respective floor levels, and
placing in suitable positions for the Sub-contractor all plant, machinery or the like
to be installed by the Sub-contractor.
(10) The provision of electrical power by Contractor for the Sub-contractor's works,
including all lighting and 3-phase or heavy supplies, which may be required for
purposes of testing and commissioning.
(11) The provision of water for the Sub-contractor's works, including the requirements
for testing and commissioning and subsequent removal of water.
(12) The provision of all fuel necessary for the testing and commissioning of the Sub-
contract works.
(13) Supplying full size setting out templates and giving and marking dimensions and
taking responsibility for their accuracy.
(14) The provision of all temporary access already fixed or placed in position on the site
for the use of workmen and the delivery of materials.
(15) The general co-ordination and integration of all Sub-contract works into the General
Programme.
(16) Ascertaining full details of any work to be executed by other Sub-contractor's in
connection with the Sub-contract works and arranging for such work to be executed
at the correct time.
(17) Protection of the Sub-contract works from the time the Sub-contractor completes
the work until the Works as a whole or any sections thereof are handed over to the
Employer.
(18) The cleaning of all Sub-contract works, as part of the final clean operation at
substantial completion of the Works as a whole or any section thereof.
(19) The provision of all general site lifting, hoisting equipment and drainage.
(20) Cutting, chasing and making good.
(21) The design co-ordination and necessary liaison related thereof.
(22) The programming of the Sub-contract Works and the necessary co-ordination to
comply with the Contractor's overall programme.
(23) Obtaining any necessary security passes, access approvals, identity cards and the
like for all sub- contractor's personnel.
(24) Other necessary and usual facilities, documentation, general inter-trades
attendance, labour and assistance.

Builder's Work in Connection

A. The expression "Builder's Work" shall mean all ancillary work carried out by the Contractor in
connection with all Sub-contract works and installations.

B. The drilling, cutting or leaving of holes or apertures through structural floors, walls, beams, etc.
shall be avoided, but where this becomes a necessity, the Contractor must obtain the written
approval of the Engineer before the work is put in hand.

C. The Contractor shall allow for all Builder's Work In Connection with the installation which should
include but is not limited to the following:
(1) Install only and install all inserts and any other anchored materials required for the
Works, which require to be embedded in the building structure and block work.
These inserts are to be provided by the Sub-contractor to the Contractor.

Page 8 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

(2) Drilling, cutting or leaving holes for pipes, ducts and the like through walls, floors,
partitions, etc. and subsequently making good / waterproofing where necessary.
(3) Cutting and pinning ends of supports for pipes, equipment, appliances, fittings and
the like to walls, floors, partitions, soffits, etc. and making good.
(4) Cutting or leaving mortises, sinking, etc. for holding down bolts, brackets, supports
and the like and grouting in.
(5) Cutting chases for pipes, conduits and the like in walls, floors, partitions, etc. and
subsequent making good.
(6) Cutting and fittings around, boring holes through and making good of finishing up
to pipes, ducts, fans, supports, brackets and the like.
(7) The construction of concrete, block and / or timber ducts.
(8) The formation of ducts within concrete slabs, together with access covers and
frames.
(9) The building of timber frames, panels and doors, including ironmongery, to give
access to pipes, ducts, equipment and the like.
(10) The formation of concrete bases, plinths, etc. for plant and equipment, including
any ant vibration pads.
(11) The waterproofing of all external ductwork to the Engineer's approval.
(12) Making good finishes after second fix installation.
(13) Secondary steel framing necessary for support of plant, pipe work, lifts, ductwork
and the like.
(14) Concrete encasement to drainage pipes and fittings below slab on grade.
(15) Elevator lifting beams, supports and other necessary Builder's Work.
(16) Fire stopping around services.
(17) Cutting and making good openings in false ceilings, bulkheads, walls for grilles,
diffusers, luminaries, sprinkler heads, loudspeakers and the like.
(18) 'Builder's Work' will include all the above, but it should be noted that this list is not
intended to be exhaustive and everything necessary will be deemed to be included.
(19) The Contractor is referred to the Structural Drawings for further information. The
Contractor shall allow for any plinths or bases required for MEP equipment
installations.
(20) Builder's Work shall include for all penetrations through concrete surfaces for MEP
Equipment, including (but not limited to) stair pressurization fans, ventilation
openings through skylight up stands, fire barrier seals as required, and the like.

DIVISION 1 - GENERAL REQUIREMENTS


A. Payment for the establishment of the items site office and facilities will be Lump Sum which
will be made only after the completion of all facilities. Breakdown of all Lump Sum amounts
to be submitted together with the Tender Submission.

B. Payment for the maintenance of site office and facilities items will be in monthly
installments.

C. Payment for the removal of site office and facilities items will be by Lump Sum which will
be made only after the completion of their removal. The removal of the Site Office for the
Engineer shall typically be one month after the completion of the Works.

Page 9 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

D. Payment for contractor’s supervision and the like, Bills of Quantities items shall be in
monthly instalments.

E. All and any costs associated with traffic management, traffic safety and control shall
be borne by the Contractor including the cost of all temporary traffic diversions and traffic
management necessary to complete the works. The item shall include but not limited
to liaison with the local authorities to confirm their requirements for safety.

F. The item for traffic safety and control shall include the cost of all temporary traffic
diversions and traffic management necessary to complete the works. The item shall include
for liaison with the local authorities to confirm their requirements for safety.

G. Temporary works, diversions, site cleaning, etc., and other items not otherwise covered in
this preamble or otherwise detailed in the Bills of Quantities will be cost related items and
will be paid as a percentage of work completed to total value of work.

H. Payment for assisting Engineer shall be in monthly instalments and is deemed to cover all
costs in providing assistance to the Engineer by the Contractor as stated in the Contract.

I. Payment for progress photographs will be by set of monthly progress photographs as


defined in the Specification.

J. Payment for Conditions of Contract will be by monthly instalments and shall cover all costs
and expenses including overhead and profits incurred by the Contractor in carrying out the
requirements of the Conditions of Contract not otherwise included in the Bills of Quantities.
Breakdown of all Lump Sum amounts to be submitted together with the Tender Submission.

DIVISION 2 - SITE CONSTRUCTION


A. Rock is as defined in CSI. The term “employer’s representative” shall mean The Engineer.

B. Boulder rock is defined as any material met with which is of such size or position that in the
opinion of the Engineer it can only be removed by means of special equipment but which does
not need breaking up prior to removal.

C. The method of measurement and remeasurement will be entirely at the discretion of the
Engineer but generally will be as follows:
(1) Where there is no reduced level excavation, other excavations will be measured
from natural ground level.
(2) In instances where there is excavation to reduce levels other excavations will be
measured from the reduced level

D. Should the Contractor be able to use any excavated material arising from the works as general
filling then it shall be measured as material backfilled in making up levels with a deduction of
items for filling and for material removed from site.

E. In addition to the provisions of CSI rates for excavation shall be deemed to include for the
following.

Page 10 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

(1) Excavating by whatever means are necessary including hand excavation in any kind
of ground, except rock and boulder rock.
(2) Overbreak including filling with mass concrete to the levels required by the Engineer.
(3) Trimming or grading ground to produce level surfaces or surfaces to falls or slopes.
(4) Ramming and compacting sides and bottoms of excavations and supports to sides.
(5) Keeping free from general water including any dewatering as necessary.
(6) Any hand excavation required around existing services or the like.

F. The rates for underground drainage shall include for the following:
(1) Short lengths, joints and cutting at manholes.
(2) Cutting and fixing pipework to fittings.
(3) Testing.

G. The rates for underground drainage shall include for the following:
(1) Short lengths, joints and cutting at manholes.
(2) Cutting and fixing pipework to fittings.
(3) Testing.

H. The rates for excavation of trenches for services, pipes or drain pipes shall include for
deepening and widening as necessary to enable the barrels of pipes, ducts, etc., to rest on
firm ground and to facilitate jointing.

I. The rates for items of imported fillings, graded gravel fillings, etc., shall include for:
(1) Levelling and compacting as required by the specification
(2) Grading to slopes and falls.
(3) Special compacting to form vertical or battering faces, and
(4) Forming sinkings.

Termite Protection

J. Measured the plinth area of the building to be treated in square metres, all costs for treatment
to vertical sides or the like of excavations are to be included in the plinth area rate.

DIVISION 3 - CONCRETE
A. The Contractor should ascertain from the Engineer the total number of locations of items to be
formed in and cast into in-situ and precast concrete including those which are not specifically
shown on the drawings. No cutting away of concrete shall be carried out without the approval
of the Engineer. All remedial works shall be carried out at the Contractor's expense.

B. The rates for all concrete work shall include for the following:
(1) Concrete test cubes and testing costs.
(2) Mixing, hoisting and placing and compacting on the surfaces of any material or on
formwork.
(3) Forming any construction joints or the like, including any required preparation for
adjacent pours.
(4) Shuttering to sloping upper surfaces not exceeding 15 degrees from horizontal.
(5) Curing and protecting concrete surfaces from harmful weather conditions.
(6) All necessary keys to concrete surfaces to receive in-situ finishes.
(7) All costs in connection with the construction of "kickers".

Page 11 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

C. The rates for plain concrete foundations and concrete blinding shall include for the following.
(1) All necessary shuttering to edges or extra volume of concrete used in lieu of shuttering.
(2) Forming sloping upper surfaces where required.

D. The rates for reinforced concrete shall include for working concrete around reinforcement.

E. The rates for bar reinforcement shall include for the following:
(1) Positioning and protecting starter bars.
(2) Straightening (if required) cutting to length and bending reinforcement to required
shapes.
(3) Cleaning and wire brushing.
(4) Supporting in position during concreting.
(5) Provision of supports (excluding links and stirrups) steel binding wire and
approved/proprietary distance pieces.
(6) Additional cutting and bonding in connection with holes, mortices, pockets, grooves,
chases and the like.
(7) Preparation of detailed reinforcement drawings and bar bending schedules for all
steelwork to be submitted to the Engineer or his representative for approval before
starting the work.

F. The rates for fabric reinforcement shall include for the following:
(1) Straight raking curved and circular cutting and waste, bending to profiles, laps of one
full square/rectangular module or as noted.
(2) Supporting in position during concreting: provision of supports (excluding special chairs)
steel binding wire and approved/proprietary distance pieces.
(3) Cutting, bending and notching around all obstructions.

G. The rates for shuttering or moulds as appropriate shall include for the following.
(1) Small quantities.
(2) All cutting and waste including raking curved or circular cutting and cutting and notching
around pipes, ducting and fittings.
(3) Setting up, strutting and supporting at any height above the structure subject to any
limitations imposed by the Engineer including all props, stays struts, wedges, bolts etc.
(4) Carefully coating with shutter oil ensuring that no shutter oil is applied to surfaces of
reinforcement.
(5) Easing, striking, removing and cleaning and preparing for re-use and removal when no
longer required.
(6) Overlaps and passings at angles and labours at intersections.
(7) Shortening struts or shapes and re-strutting or re-shoring where required.
(8) Rubbing down, filling and making good the surface of concrete after removal of
shuttering.
(9) Cutting or notching shutters or moulds to in-situ or precast concrete around projecting
reinforcement.
(10)Shuttering to sides of walls, parapets or the like shall include the areas for returns, ends,
projections, reveals, rebates, grooves, recesses or the like.

H. The rates for wrought shuttering/shuttering to produce a special finish shall include for the
following:

Page 12 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

(1) Any necessary rubbing down or filling allowed by the specification to produce the finish
required.
(2) Cutting out and re-casting unsatisfactory work or work not fulfilling the requirements
of the specification or carrying out remedial or any other work required by the Engineer
as an alternative to cutting out substandard work.

I. The rates for precast concrete shall include for the following:
(1) The provision of moulds.
(2) Forming a fair face in accordance with the specification to all exposed surfaces.
(3) Hacking or forming keys to all other surfaces.
(4) Lifting hooks or other devices approved by the Engineer for positioning.
(5) Bedding jointing in mortar as specified.
(6) All necessary temporary struts or supports.
(7) Sills, copings, etc., shall include for plain ends and mitred angles where necessary.

Reinforcement to Masonry

J. The contents of this section equally apply to reinforcement included within the Masonry section
of the Bills of Quantities, unless otherwise stated.

DIVISION 4 - MASONRY
A. The rates for block walls shall include for the following:
(1) Block testing at a recognised laboratory, provision of certificates.
(2) Small quantities and any extra labour in forming kerbs.
(3) Straight raking curved and circular rough or fair cutting, plumbing at angles, cutting and
bonding at angles, openings and intersections, building into and/or against adjacent
work, wedging and pinning up to soffits.
(4) Special or concrete filled blocks at angles, door, window and openings or the like, and
intersections and load bearing walls including any necessary reinforcement.
(5) Providing any means necessary to prevent concrete cast on hollow blockwork or over
cavities from falling into voids or cavities (subject to the approval of the Engineer).
(6) All necessary keys for in-situ finishings.
(7) Grouting up at back of walls built against other construction.
(8) All necessary wall ties, dowels, straps, sleeves, channels and other like fixings built-in at
junctions between blockwork and in-situ concrete including casting in, drilling, bolting
and the like.
(9) All necessary blockwork reinforcement at junctions between blockwork and walls,
construction joints or the like and openings.
(10)All necessary construction, contraction joints, slip strip or the like.
(11)Filling top course of hollow block walls with concrete/ mortar below slabs and slip strips,
etc. between top of load bearing block walls and slabs.

B. The rates for block walls shall include for the following additional labours:
(1) Cutting or forming chases or grooves for slabs, partitions, staircases, etc.
(2) Cutting grooves for water bars, flashings and the like and making good and pointing
in similar mortar.
(3) Building in or cutting and pinning in and making good ends of lintels, brackets,
timbers, steelwork, holderbats and the like.

Page 13 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

(4) Building in or cutting for and making good around pipes, ducting, fittings and the
like.

DIVISION 5 - METALS
A. Rates for metalwork / steelwork shall include for all cutting, drilling, counter-sinking, bolting,
riveting, welding, boring, grinding, bracing, grinding off flush, etc., assembling, hoisting and
fixing in position, adjusting, site and shop priming and touching up as necessary.

B. Preparing and submitting workshop drawings before fabrication commences.

C. Scribing, rebates, grooves, chambers, splayed and rounded edges, fair and returned ends,
mitres, and the like and for all short isolated lengths.

D. Rates for balustrade and handrails shall include for bends, mitres, crosses, tees, flanged ends,
angles, intersections, ramps, bearers, holes, conduits and the like.

E. The rates for steelwork shall include for all stanchions and rafters, gussets, endplates, and the
like and for the preparation of all shop drawings. Ungalvanized steel shall include for rust proof
primer.

F. Only main steelwork members have been measured. All fixings and fittings are to be included
in the rates.

G. The carrying out of special tests to welded or other joints or connections in steelwork shall be
given as an item.

H. Gutters have been measured by length taken along the center line over all fittings. All painting
and fittings to gutters shall be included in the rates.

I. Weights do not include any secondary members that may be required by the cladding contractor
to support cladding.

J. Provision of method statement, samples, and any mock-up/placement samples as required by


the Engineer.

K. Preparation and furnishing to the Engineer of detailed workshop drawings and design
calculations for approval.

L. Fireproof treatment required to meet fire rating of the spaces where located, to Civil Defense
Authority and Engineer’s approval.

DIVISION 6 – WOODS AND PLASTICS


A. The rates for all woodwork shall include for all raking, curved or splayed cutting, mitres and ends
to all members, for all joints in members over 200mm wide for obtaining timbers in one width,
notching, sinking, rounded curves, splayed edges, extra timber in joints, homes, etc., all dowels
and cramps and holes for pipes, bar, cables, conduits, ducting, trunking and the like.

Page 14 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

B. The rates shall further include for rebates, chamfers, grooves, scribed edges, rounded
edges, gluing, clamping, labours and the like, and shall include for all cross grain and stopped
work and for all stops, ends, angles and mitres.

C. The rates shall include for supply and installation of all ironmongery, hardware and accessories
unless specifically measured separately.

D. The rates for doors are to include for fitting and hanging any type, weight, size and in any
material. Also the installation of ironmongery and hardware, unless measured separately.

DIVISION 7 - THERMAL AND MOISTURE CONTROL


A. The rates for work in this section shall include for the following:
(1) Laps, seams and narrow widths, straight raking curved and circular cutting and all
consequent wastage, angles, returned ends and dressed ends on flashings. Dressing up
and over upstands and around and into gargoyles, rain water outlets, vent pipes and
the like.
(2) Tropical grade mastic pointing to all wall flashings.
(3) Testing.

Finishes

B. Applied finishes described in this section are deemed to be measured as the relevant preamble
in which they occur.

Insulation

C. Prices to be inclusive of all items as described above.

DIVISION 8 – DOORS AND WINDOWS


A. This section shall be read particularly in conjunction with the woodwork section.

B. Items measured in this section shall be described primarily by stating the size and giving
other information required by the CSI.

C. The rates for glazing shall include for the following:


(1) Panes of any size.
(2) All straight raking, curved and circular cutting and all consequent wastage.
(3) Patterned and wired glass shall include aligning adjacent panes.
(4) Appropriate bedding strips in conjunction with fixing beads.
(5) Glazing fillets shall include pinning to wood or clipping to metal unless otherwise
stated.
(6) Patent glazing shall include accessories and shall be fixed by the method required by
the system used, hardwood framing to either be inclusive of the window unless
measured separately.
(7) Glazing shall include blocks, setting blocks, locating blocks, distance pieces and the
like accessories for fixing.

Page 15 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

(8) Cleaning off protective wax coating in rebates prior to glazing aluminium windows,
screens and doors.
(9) Glazing to aluminium shall include setting in continuous PVC gaskets and retaining by
snap-fit glazing beads.

DIVISION 9 - FINISHES
A. Rates for finishes generally shall be deemed to include for:
(1) Thoroughly wetting solid surfaces to be rendered or screeded including dubbing out
to walls and provision of levelling screed to floors or the like.
(2) Raking out joints of block work, hacking surfaces of concrete or applying bonding
agent to form a key.
(3) Making good or cutting and fitting around pipes, gratings, sanitary, fittings,
standards and the like, making good up to door and window frames, skirting's and
the like, temporary rules working around buried services.
(4) Narrow widths, small and isolated areas, rounded arises, fair and chamfered edges
and the like.
(5) Angle beads, corner bead, tile trims and render stops around doors, windows,
vertical and horizontal abutments and the like, reinforcing mesh at joints and
between different surfaces; internal angle beads shall be galvanized metal and
external angle beads shall be stainless steel unless otherwise specified.
(6) Work executed overhead, in restricted areas and the like. vii) Masking before the
application of sprayed finishes.
(7) Access panels.
(8) Working at or up to any height, narrow widths, small areas and all cuttings.
(9) Expansion joints and control joints as specification.

B. Rates for screed shall be deemed to include for:


(1) Finishing with a temped, floated or trowelled surface or power float as required.
(2) Laying level or to falls, cross falls or slopes as required, particularly in wet areas and
providing a levelling coat as required.

C. Rates for painting shall be deemed to include for:


(1) All cleaning and preparatory work to the surfaces to be painted, cutting to line;
rubbing down between coats.
(2) Working to or at any height, and all narrow widths.
(3) The rates for painting on wood shall include for work on hardwood and softwood
including knotting and primer coat.
(4) Painting to opening edges of doors and work on additional surfaces exposed by such
opening edges.
(5) Painting to all pipes, ducts, fittings, etc. as no allowance has been made in measured
items.

D. Rates for suspended ceilings shall include for:


(1) Supplying shop drawings and for obtaining approval of details before commencing
work.

Page 16 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

(2) Primary and secondary grids as necessary and for suspending the same with
requisite hangers from the soffits. Perimeter trim and all cutting and fitting plus cost
of providing all access panels shall be included in the rates.
(3) Any additional suspension member necessary to support lighting fittings or similar.
(4) All decorative and bulk heads lighting cores. All circular, square or rectangular
cutting for light fittings including all necessary supports.

DIVISION 10 - SPECIALITIES
A. The rates for accessories shall include for fixing to any type of surface, all necessary screws,
bolts, nuts, washers, nails, pins and similar items required but which are not supplied with the
accessories, all fitting, cutting, housing, sinking, boring, morticing, drilling and similar labours to
the surface which the article is being fixed and making good to surrounding materials.

DIVISION 11 - EQUIPMENT
A. Unless otherwise described the whole of the Equipment shall be executed in accordance with
the relevant Specification Clauses.

DIVISION 12 - FURNISHINGS
A. Unless otherwise described the whole of the Furnishings shall be executed in accordance with
the relevant Specification Clauses.

DIVISION 13 – SPECIAL CONSTRUCTION


A. Unless otherwise described the whole of the Special Equipment shall be executed in accordance
with the relevant Specification Clauses.

DIVISION 14 – CONVEYING SYSTEMS


A. Unless otherwise described the whole of the Conveying Systems shall be executed in
accordance with the relevant Specification Clauses.

DIVISION 15 - MECHANICAL ENGINEERING INSTALLATIONS


A. Unless otherwise stated, the items are to include for the: supply, installation, labelling,
connections, testing as necessary. All in accordance with the Specifications and Drawings.

B. Rates for all piping are to include for providing suitable sleeves where pipes pass through
internal and external walls, partitions, ceilings, etc.

C. Rates for all pipes shall include for all short lengths, sockets, running couplings and joints,
standard pipe supports, cutting and waste. Measurement shall be through centerline of pipes
and through fittings.

D. Unless otherwise stated, tee couplings and connections are identified by the nominal diameter
of the largest pipe connected thereto and the rates for these items are to include for any
reducing tee required.

Page 17 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

E. Rates shall include for stopping ends of pipes by an approved method while the work is in
progress to prevent ingress of rubbish and for leaving all pipes clean and clear on completion.

F. Rates shall include for coordination with other engineering installations.

G. Rates shall include for cutting for forming holes, mortises, chases or the like and making good
finishing's.

H. Rates shall include for building in, cutting and pinning brackets or the like and making good
finishing's.

I. Rates for all ductwork of any type, system or material shall include for all fittings, flanges, access
doors, bolting and the like. Measurement shall be through centerline of ducts measured
through fittings.

J. The Contractor shall include for the supply of manufacturers recommended spares in
accordance with the specification for all Mechanical Engineering Installations.

K. The Contractor shall allow for the following


(1) All permits, fees, inspection associated with the mechanical installations by utility and
statutory authorities.
(2) Setting out the works, marking positions of holes, mortices, chases or the like.
(3) All testing and commissioning and production of test certificates.
(4) All protective and decorative painting and cleaning of pipes, fittings and equipment.
(5) All identification labels, plates, charts and identification of plant, equipment, cable,
switches and the like.
(6) Preparing schedule of manufacturers recommended tools and spare parts for each
piece of equipment.
(7) The provision of operating/maintenance manuals.
(8) Providing shop, co-ordination and "as-built" drawings.
(9) Instructing selected employer's personnel on all aspects of the operation of systems and
equipment.
(10)All access panels.
(11)All firestopping in accordance with the drawings, specification and local authorities
requirements.
(12)All builders work in connection with the whole of the mechanical installation including
all manholes, sumps, pits, etc.
(13)Domestic water piping sterilisation after commissioning.

DIVISION 16 - ELECTRICAL ENGINEERING INSTALLATIONS


A. Rates for the installations shall include for any portion of the works which could be reasonably
and obviously inferred as necessary for the complete and satisfactory operation for the
installation as a whole, although no expressly described or specified.

Page 18 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

B. Unless otherwise stated, the Bills of Quantities items are to include for the: supply, installation,
terminations, labelling, connections, testing as necessary. All in accordance with the
Specifications and Drawings.

C. The rates for switchboards, switchgear, distribution boards, control gear, fittings, equipment
and the like shall include for:
(1) All identification labels, warning notices, circuit schedules and the like b)The
completion of the circuit schedules
(2) All necessary gland plates and cable entry boxes
(3) All earth tapes, cables and connections to associated cable termination glands,
conduit and/or trunking.

D. Main circuits (defined as “the incoming supply to the distribution boards within a building”) shall
be measured as follows)
(1) Cables shall be measured by length and shall be deemed to include colour coding,
marking, joints, boxes, line tops, shrouds, termination glands, connectors, supports,
sleeves, plates and the like.
(2) Conduit shall be measured by length and shall be deemed to include conduit boxes,
all fittings, saddles, crumpets bending, cutting, screwing, jointing and the like.
(3) Trays and trunking shall be measured by length and shall be deemed to include
all fittings, stools, saddles, cleats, clips, fire barriers, pin racks, cutting, jointing,
earth continuity components and the like. Trunking shall also be deemed to be
included.

E. Sub main circuits (defined as “supply from a distribution board to a sub-main distribution
board”) shall be measured in accordance with CSI.

F. The rates for enumerated points, outlets, equipment and the like shall be deemed to include
cables, conduit, trunking, trays, earthling tape and all equipment and accessories necessary to
provide power.

G. Spacing of components for supporting earthing tapes or cables has not been stated and the
rates for earthling tapes and cables shall include for all saddles, cleats, clips hold fasts and the
like to suit site conditions.

H. The length of pendant drops are not stated and the rates for lighting fittings shall include for
pendant drops, boxes, conduit boxes, wood blocks, moulded pattresses, break joint rings,
ceiling roses, connector blocks, dome covers, back plates, ball and socket back plates, earth
continuity, flexible cords, chokes, capacitors, starters, lamp holders and the like.

I. The rates for all lighting fittings shall include for all associated lamps, control gear, diffusers,
shades and the like.

J. The rates for clocks, telephones, fire alarms, burglar alarms, loudspeakers and the like shall
include where required for all boxes, conduit boxes, woodblock, moulded pattresses, cover
plates and the like.

K. The rates for all socket outlets include for associated plug tops.

Page 19 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

L. The rates for surface accessories shall include for any necessary back plates and surface
mounting boxes.

M. The rates for all flush, semi-flush, recessed, semi-recessed and insertion items shall include for
any necessary boxes.

N. The rates for all accessories, fittings, equipment and the like shall include for all necessary
earthling tails and terminals.

O. Rates shall include for coordination with other engineering installations.

P. Rates shall include for cutting or forming holes, mortises, chases or the like and making good
finishings (to be done by Main Contractor).

Q. Rates shall include building in or cutting and pinning brackets or the like and making good
finishings (to be done by Main Contractor).

R. The Contractor shall include for the supply of manufacturers recommended spares in
accordance with the specification for all Electrical Engineering Installations.

S. The Contractor shall allow for the following


(1) All permits, fees, inspection associated with the electrical installations by utility and
statutory authorities.
(2) Setting out the works, marking positions of holes, mortices, chases or the like.
(3) All testing and commissioning and production of test certificates.
(4) All protective and decorative painting of fittings and equipment.
(5) All identification labels, plates, charts and identification of plant, equipment, cable,
switches and the like.
(6) Preparing schedule of manufacturers recommended tools and spare parts for each
piece of equipment.
(7) The provision of operating/maintenance manuals.
(8) Providing shop, co-ordination and "as-built" drawings.
(9) Instructing selected employer's personnel on all aspects of the operation of systems and
equipment.
(10)All firestopping in accordance with the drawings, specification and local authorities
requirements.
(11)All builders work in connection with the whole of the electrical installation including all
manholes, sumps, pits, etc.

Page 20 of 21
BILLS OF QUANTITIES – PRICING PREAMBLES

SERVICES GENERALLY
A. The Tenderer shall be completely responsible for obtaining the requirements for holes, fixings,
and any other Builder’s Work. He shall coordinate the requirements for Builders Work between
trades and ensure that such information is as shown on the Drawings in accordance with their
own and the Employer's requirements. Details of Builder’s Work which is not shown on the
Drawings but which is required by the Contractor shall be forwarded to the Engineer for their
written approval before the work is put in hand. Any cost of unnecessary work due to the
Contractor failing to comply with these conditions or failing to act upon such information given
be borne entirely by the Contractor.

B. The drilling, cutting or leaving of holes or apertures through structural floors, walls, beams, etc.,
shall be avoided, but where this becomes a necessity the contractor must obtain the written
approval of the Engineer before such work is put in hand.

BUILDER’S WORK
A. The expression used here “Builder’s Work” related to services includes but is not limited to the
following:
(1) Drilling, cutting or leaving of holes for pipes, ducts and the like through walls, floors,
partitions, roofs, etc. and subsequently making good.
(2) Cutting and pinning ends of supports for pipes, equipment, appliances, fittings and
the like to walls, floors, partitions, soffits, etc., and making good.
(3) Cutting or leaving mortises, sinkings, etc., for holding down bolts, brackets,
supports and the like and grouting in.
(4) Cutting chases for pipes and the like in walls, floors, partitions, etc., and
subsequently making good.
(5) Cutting and fitting around, boring holes through and making good of finishing's up
to pipes, supports, brackets, and the like.
(6) The formation of small concrete bases, plinths, etc. for plant, tanks and equipment,
including anti-vibration pads as necessary.
(7) Making good finishes as necessary after installation.
(8) The painting of exposed pipe work, fittings, equipment, etc.

B. “Builder’s Work” will include all the above, but it should be noted that this list is not intended
to be exhaustive and everything necessary will be deemed to be included.

Page 21 of 21
Bill No. 1 GENERAL REQUIREMENTS
MAIN CONTRACT
INTERCONTINENTAL RESORT HOTEL
RAK PROPERTIES

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

EMPLOYER'S REQUIREMENTS

Site accommodation

Site accommodation

A Bringing to site and installing, including all


temporary drainage services and intruder alarms ITEM

B Charges ITEM

C Maintaining (minor repairs) ITEM

D Cleaning ITEM

E Adaptations/alterations during works ITEM

F Dismantling and removing from site, including


rectifying any damage ITEM

G Off-site rented temporary accommodation ITEM

H Rectifying damage to off-site rented temporary


accommodation ITEM

Furniture and equipment

J Bringing to site and installing ITEM

K Charges ITEM

L Cleaning ITEM

M Dismantling and removing from site ITEM

Telecommunication and IT systems

N Purchase charges ITEM

P Hire charges ITEM

Q Consumables ITEM

To Collection

Bill No. 1 - Page 1


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

EMPLOYER'S REQUIREMENTS

Site records

Site records

A Operation and maintenance manuals ITEM

B Compilation of health and safety file ITEM

C Web-based documentation project management


systems ITEM

Completion and post-completion requirements

Handover requirements

D Training of building user’s staff in the operation


and maintenance of the building engineering
services systems. ITEM

E Provision of spare parts for maintenance of


building engineering services. ITEM

F Provision of tools and portable indicating


instruments for the operation and maintenance
of building engineering services systems. ITEM

Operation and maintenance services

G Operation and maintenance of building


engineering services ITEM

MAIN CONTRACTOR'S COST ITEMS

Management and staff

Project specific management and staff

H Contractor’s project manager ITEM

J Construction manager ITEM

To Collection

Bill No. 1 - Page 2


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Management and staff

Project specific management and staff

A Supervisors, including works/trade package


managers, building services engineering
managers/co-ordinators and off-site production
managers. ITEM

B Health and safety manager/officers ITEM

C Commissioning manager – building engineering


services. ITEM

D Planning/programming manager and staff. ITEM

E Senior/managing quantity surveyor. ITEM

F Project/package quantity surveyors. ITEM

G Procurement manager. ITEM

H Design manager and staff ITEM

J Project engineers. ITEM

K Environmental manager. ITEM

L Temporary works design engineers. ITEM

M Materials management staff (e.g. storeman). ITEM

N Administrative staff, including secretary,


document controllers, finance clerks and the like. ITEM

P Other management and staff. ITEM

Visiting management and staff

Q Managing director, regional director, operations


director, commercial director and the like. ITEM

R Quality manager. ITEM

S Contract/commercial manager. ITEM

To Collection

Bill No. 1 - Page 3


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Management and staff

Visiting management and staff

A Health and safety manager. ITEM

B Environmental manager/consultant. ITEM

C Other visiting management and staff. ITEM

Extraordinary support costs

D Legal advice costs ITEM

E Recruitment costs. ITEM

F Team building costs. ITEM

G Other extraordinary support costs. ITEM

H Day transport. ITEM

J Personnel transport ITEM

K Temporary living accommodation ITEM

L Subsistence payments. ITEM

M Out-of-hours working. ITEM

Staff travel

N Visits to employer and consultants’ offices. ITEM

P Visits to subcontractors’ offices/works. ITEM

Q Overseas visits. ITEM

R Accommodation charges and overnight


expenses. ITEM

To Collection

Bill No. 1 - Page 4


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Site establishment

Main Contractor's Furniture and equipment

A Workstations for staff, including maintenance. ITEM

B General office furniture, including maintenance ITEM

C Conference/meeting room furniture, including


maintenance ITEM

D Photocopiers, including purchase/rental,


maintenance and other running costs ITEM

E Canteen furniture, including maintenance ITEM

F Canteen equipment, including purchase/rental,


maintenance and other running costs ITEM

G Floor coverings, including maintenance. ITEM

H Water dispensers, including purchase/rental,


maintenance and other running costs ITEM

J Heaters, including maintenance of heaters ITEM

K Other office equipment, including maintenance ITEM

L Removal of furniture and equipment. ITEM

M Maintenance furniture and floor covering. ITEM

Site accommodation

N Purchase charges. ITEM

P Hire and purchase ITEM

Q Delivery of temporary site accommodation to


site, erection, construction and removal. ITEM

R Temporary accommodation made available by


the employer. ITEM

S Intruder alarms. ITEM

To Collection

Bill No. 1 - Page 5


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Site establishment

Site accommodation

A Land/property rental where site accommodation


located off-site. ITEM

B Alterations and adaptations to site


accommodation, including partitioning, doors,
painting and decorating, and the like. ITEM

C Relocation and alterations of temporary


accommodation during construction stage. ITEM

D Reinstating temporary site accommodation to


original condition prior to removal from site. ITEM

E Removal of site accommodation and temporary


works in connection with site accommodation. ITEM

Temporary works in connection with site


establishment

F Temporary bases and foundations for site


accommodation, including maintenance,
removal and reinstatement of all disturbed
existing surfaces on completion of the works. ITEM

G Connections to temporary service, including


maintenance, removal and reinstatement of all
disturbed existing surfaces on completion of the
works. ITEM

H Connections to temporary drainage including


maintenance, removal and reinstatement of all
disturbed existing surfaces on completion of the
works. ITEM

J Temporary site roads, paths and pavings


(including on-site car parking), including
maintenance, removal and reinstatement of all
disturbed existing surfaces on completion of the
works. ITEM

To Collection

Bill No. 1 - Page 6


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Site establishment

Temporary works in connection with site


establishment

A Temporary surface water drainage to temporary


site roads, paths and pavements, including
maintenance, removal and reinstatement of all
disturbed existing surfaces on completion of the
works. ITEM

IT systems

B Computer hardware, including purchase/rental,


installation, initial set up, maintenance and
running costs, such as:– desktop computers and
laptop computers – CAD stations – server and
network equipment – printers and plotters –
other computer system hardware. ITEM

C Software and software licences. ITEM

D Modem lines, modems and connections (i.e.


email and internet capability). ITEM

E WAN lines and connections (if onWAN). ITEM

F Line rental charges. ITEM

G Internet/website addresses. ITEM

H Internet service provider (ISP) charges. ITEM

J Line calls charges. ITEM

K IT support and maintenance ITEM

Consumables and services

L Stationery. ITEM

M Computer and printer consumables (e.g. ink


cartridges). ITEM

N Postage. ITEM

To Collection

Bill No. 1 - Page 7


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Site establishment

Consumables and services

A Courier charges. ITEM

B Tea, coffee, water bottles and the like. ITEM

C First aid consumables. ITEM

D Photocopier consumables (e.g. paper and


toners). ITEM

E Fax consumables (e.g. paper and toners). ITEM

F Drawing printer consumables (e.g. ink


cartridges). ITEM

Brought in services

G Catering. ITEM

H Equipment maintenance. ITEM

J Document management, including electronic


data management systems (EDMS). ITEM

K Printing (purchasing), including reports and


drawings. ITEM

L Staff transport. ITEM

M Off-site parking charges. ITEM

N Meeting room facilities. ITEM

P Photographic services. ITEM

Sundries

Q Main contractor’s signboards. ITEM

R Safety and information notice boards. ITEM

S Fire points. ITEM

To Collection

Bill No. 1 - Page 8


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Site establishment

Sundries

A Shelters. ITEM

B Tool stores. ITEM

C Crane signage. ITEM

D Employer’s composite signboards. ITEM

Temporary water supply

E Temporary connections. ITEM

F Distribution equipment, installation and


adaptations. ITEM

G Meter charges. ITEM

Temporary gas supply

H Distribution equipment, installation and


adaptations. ITEM

J Gas connection. ITEM

K Charges. ITEM

L Bottled gas. ITEM

Temporary electricity supply

M Temporary connections. ITEM

N Distribution equipment, installation and adaptations. ITEM

P Temporary electrical supply for tower cranes. ITEM

Q Charges – power consumption for site establishment. ITEM

R Charges – power consumption for the works. ITEM

To Collection

Bill No. 1 - Page 9


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Site establishment

Temporary electricity supply

A Attendance. ITEM

B Uninterrupted power supply (UPS). ITEM

C Temporary substation modifications. ITEM

Temporary telecommunication systems

D Landlines (including connection and rental


charges), including: – telephone and fax lines –
ISDN lines. ITEM

E Telephone and facsimile equipment (including


connection and rental charges), including: –
PABX equipment – handsets, including
purchase or rental – fax machines, including
purchase or rental – installation of equipment –
maintenance of equipment. ITEM

F Mobile (cellular) phones, including: – mobile


phones, including purchase or rental and
connection charges – spare batteries – mobile
phone charges. ITEM

G Telephone charges, including: – telephone call


charges – fax charges – fax and telephone
consumables. ITEM

H Radios (including purchase or rental charges),


including: – base set – handsets and chargers
– repairs and maintenance – licences – spare
batteries. ITEM

Temporary drainage

J Temporary mains. ITEM

K Septic tanks. ITEM

L On-site treatment plant. ITEM

To Collection

Bill No. 1 - Page 10


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Site establishment

Temporary drainage

A Holding tanks. ITEM

B Sewage pumping. ITEM

C Distribution pipework, etc. ITEM

D Drainage installation and adaptations. ITEM

E Disposal charges (i.e. rates). ITEM

F Disposal costs (i.e. tanker charges). ITEM

Security

Security staff

G Security guards (day and night). ITEM

H Watchmen (day and night). ITEM

Security equipment

J Site pass issue equipment. ITEM

K Site pass consumables. ITEM

L CCTV surveillance installation, including


cameras ITEM

M Temporary vehicle control barriers. ITEM

Hoardings, fences and gates

N Perimeter hoardings and fencing and the like to


site boundaries and to form site compounds. ITEM

P Access gates, including frames and


ironmongery. ITEM

Q Painting of hoardings, fencing, gates, and the


like. ITEM

To Collection

Bill No. 1 - Page 11


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Security

Hoardings, fences and gates

A Temporary doors. ITEM

B Modification to line of hoarding and fencing


during construction. ITEM

C Dismantling and removal of hoarding, fencing,


gates, and the like. ITEM

Safety and environmental protection

Safety programme

D Fire points. ITEM

E Health and safety manager/officers. ITEM

F Safety audits, including safety audits carried out


by external consultant. ITEM

G Staff safety training. ITEM

H Site safety incentive scheme ITEM

J Notices and information to neighbours. ITEM

K Personal protective equipment (PPE), including


for employer and consultants. ITEM

L Personal protective equipment (PPE) for


multi-service gangs. ITEM

M Temporary fire alarms. ITEM

N Fire extinguishers. ITEM

P Statutory safety signage. ITEM

Q Nurse ITEM

R Traffic marshals. ITEM

To Collection

Bill No. 1 - Page 12


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Safety and environmental protection

Safety programme

A Temporary traffic lights. ITEM

Barriers and safety scaffolding

B Guard rails and edge protection (e.g. to edges


of suspended slabs and roofs), including supply,
erection, maintenance and dismantling on
completion of the works ITEM

C Temporary staircase balustrades (i.e. to new


staircases during construction), including
supply, erection, maintenance and dismantling
on completion of the works ITEM

D Lift shaft protection, including supply, erection,


maintenance and dismantling on completion of
the works ITEM

E Protection to holes and openings in ground floor


slabs, suspended slabs and the like, including
supply, erection, maintenance and dismantling
on completion of the works ITEM

F Debris netting/plastic sheeting, including supply,


erection, maintenance and dismantling on
completion of the works ITEM

G Fan protection, including supply, erection,


maintenance and dismantling on completion of
the works ITEM

H Scaffold inspections. ITEM

J Hoist run-offs, including supply, erection,


maintenance and dismantling on completion of
the works ITEM

K Protective walkways, including supply, erection,


maintenance and dismantling on completion of
the works ITEM

To Collection

Bill No. 1 - Page 13


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Safety and environmental protection

Barriers and safety scaffolding

A Other safety measures, including supply,


erection, maintenance and dismantling on
completion of the works ITEM

Environmental protection measures

B Control of pollution ITEM

C Residual control of noise ITEM

D Environmental monitoring ITEM

E Environmental manager/consultant ITEM

F Environmental audits, including safety audits


carried out by external consultant ITEM

Control and protection

Surveys, inspections and monitoring

G Surveys. ITEM

H Topographical survey. ITEM

J Non-employer dilapidation survey. ITEM

K Structural/dilapidations survey adjoining


buildings. ITEM

L Environmental surveys. ITEM

M Movement monitoring. ITEM

N Maintenance and inspection costs. ITEM

Setting out

P Setting out primary grids. ITEM

Q Grid transfers and level checks. ITEM

To Collection

Bill No. 1 - Page 14


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Control and protection

Setting out

A Maintenance of grids. ITEM

B Take over control and independent checks (i.e.


on change of subcontractors). ITEM

C Instruments for setting out. ITEM

Protection of works

D Protection of finished works to project handover. ITEM

E Protection of stairs, balustrades and the like


works to project handover. ITEM

F Protection of fittings and furnishings works to


project handover. ITEM

G Protection of entrance doors and frames works


to project handover. ITEM

H Protection of lift cars and doors works to project


handover. ITEM

J Protection of specifically vulnerable products to


project handover. ITEM

K Protection of all sundry items. ITEM

Samples

L Provision of samples. ITEM

M Provision of sample room. ITEM

N Mock ups and sample panels. ITEM

P Testing of samples/mock ups, including testing


fees. ITEM

Q On site laboratory equipment. ITEM

To Collection

Bill No. 1 - Page 15


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Control and protection

Samples

A Mock ups of complete units (e.g. residential


units, student accommodation units, hotel
accommodation and the like). ITEM

Environmental control of building

B Dry out building. ITEM

C Temporary heating/cooling. ITEM

D Temporary waterproofing, including over roofs. ITEM

E Temporary enclosures. ITEM

Mechanical plant

Tower cranes

F Dismantling and removing from site ITEM

G Hire charges (type of tower crane to be stated,


including type and length of jib, and lifting
capacity) ITEM

H Crane operator. ITEM

J Overtime for crane and operator. ITEM

K Piles for tower crane bases including installation


and removal on completion of the works (size of
base in m2, and number of piles supporting
base, to be stated). ITEM

L Temporary bases and or ground anchors for


tower cranes, including installation,
maintenance, removal and reinstatement of all
disturbed surfaces on completion of the works
(size of base in m2 to be stated). ITEM

M Ties ITEM

To Collection

Bill No. 1 - Page 16


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Mechanical plant

Tower cranes

A Connections to temporary electrical supply ITEM

B Bring to site, erection, test and commission ITEM

C Periodic safety checks/inspections ITEM

D Other costs specific to tower crane such as: –


chain pack and sundries – relief operator –
banksman – man cage ITEM

E Temporary voids in building structure for


craneage, hoists and the like including filling
voids after removal. ITEM

Mobile cranes

F Attendance. ITEM

G Mobile crane hire charges, including


driver/operator charges (type of mobile crane to
be stated) ITEM

H Other costs specific to mobile crane hire. ITEM

Hoists

J Goods and passenger hoists, including


protection cages and embedment frames. ITEM

K Hoist bases. ITEM

L Bringing to site, erecting, testing and


commissioning. ITEM

M Dismantling and removing from site. ITEM

N Protection systems. ITEM

P Hoist operator, including overtime. ITEM

Q Beam hoists. ITEM

To Collection

Bill No. 1 - Page 17


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Mechanical plant

Hoists

A Periodic safety checks/inspections. ITEM

B Other costs specific to temporary hoist


installations. ITEM

Access plant

C Fork lifts. ITEM

D Scissor lifts. ITEM

E Loading platforms. ITEM

F Maintenance of mechanical access equipment. ITEM

G Other costs specific to mechanical access


equipment. ITEM

Concrete plant

H Dismantling and removing from site. ITEM

J Concrete plant. ITEM

K Plant operator. ITEM

L Overtime for plant and operator. ITEM

M Bases for concrete plant, including installation,


maintenance, removal and reinstatement of
disturbed surfaces on completion of the works
(size in m2 to be stated). ITEM

N Power connections, including cabling and


statutory undertaker’s charges for temporary
connection to their supply. ITEM

P Bringing concrete plant to site, erecting, testing


and commissioning. ITEM

Q Maintenance of concrete plant. ITEM

To Collection

Bill No. 1 - Page 18


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Mechanical plant

Other plant

A Small plant and tools. ITEM

Temporary works

Access scaffolding

B Dismantling and removing from site. ITEM

C Bringing to site, erecting and initial safety


checks. ITEM

D Hire charges. ITEM

E Altering and adapting during construction. ITEM

Temporary works

F Dismantling and removing from site. ITEM

G Bringing to site, erecting and initial safety


checks. ITEM

H Hire charges. ITEM

J Altering and adapting during construction. ITEM

MC Site records

Site records

K Photography ITEM

L Works records ITEM

Web-based documentation management systems

M Attendance on system provider ITEM

To Collection

Bill No. 1 - Page 19


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

MC Completion and post-completion requirements

Testing and commissioning plan

A Preparation of commissioning plan ITEM

Handover

B Provision of tools and portable indicating


instruments for the operation and maintenance
of building engineering services systems. ITEM

C Preparation of Handover Plan. ITEM

D Training of building user’s staff in the operation


and maintenance of the building engineering
services systems. ITEM

E Provision of spare parts for maintenance of


building engineering services. ITEM

F Pre-completion inspections. ITEM

G Final inspections. ITEM

Post-completion services

H Supervisory staff (employer/tenant care). ITEM

J Handyman. ITEM

K Minor materials and sundry items. ITEM

L Insurances. ITEM

M Other post-construction staff. ITEM

Cleaning

Site tidy

N Cleaning site accommodation – internal,


including cleaning telephone handsets, other
office furniture and equipment and window
cleaning. ITEM

To Collection

Bill No. 1 - Page 20


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Cleaning

Site tidy

A Periodic maintenance of site accommodation,


including redecoration (internal and external). ITEM

B Waste management, including rubbish disposal


(including compactor visits; skips and waste
bins; roll-off, roll-on waste bins) and other
disposal. ITEM

C Pest control. ITEM

Maintenance of roads, paths and pavings

D Maintenance of temporary site roads, paths and


pavements. ITEM

E Maintenance of public and private roads,


including wheel spinners and road sweepers. ITEM

Building clean

F Final builder’s clean. ITEM

Fees and charges

Fees

G Building control fees, where not paid by the


employer. ITEM

H Oversailing fees, where not paid by the


employer. ITEM

J Considerate Constructors’ Scheme fees (or


alternative scheme operated by local authority). ITEM

K Building scheme registration fees (e.g. NHBC


Buildmark) or similar fees, where not paid by the
employer. ITEM

To Collection

Bill No. 1 - Page 21


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Fees and charges

Charges

A Rates on temporary accommodation. ITEM

B Licences in connection with hoardings,


scaffolding, gantries and the like. ITEM

C Licences in connection with crossovers, parking


permits, parking bay suspensions and the like. ITEM

Site services

Temporary works

D Temporary works which are not specific to an


element. ITEM

Multi-service gang

E Ganger. ITEM

F Labour. ITEM

G Fork lift driver. ITEM

H Service gang plant and transport. ITEM

Insurance, bonds, guarantees and warranties

Works insurances

J Contractors ‘all risks’ (CAR) insurance. ITEM

K Workmen compensation insurance ITEM

L Contractor’s plant and equipment insurance. ITEM

M Temporary buildings insurance. ITEM

N Terrorism insurance. ITEM

P Other insurances in connection with the works. ITEM

To Collection

Bill No. 1 - Page 22


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Insurance, bonds, guarantees and warranties

Works insurances

A Insurance premium tax (IPT). ITEM

B Allowance for recovery of all or part of insurance


premium excess. ITEM

Public liability insurances

C Insurance premium tax (IPT). ITEM

D Allowance for recovery of all or part of insurance


premium excess. ITEM

E Non-negligence insurance. ITEM

F Professional indemnity insurance. ITEM

Employer’s (main contractor’s) liability insurances

G Insurance premium tax (IPT). ITEM

H Allowance for recovery of all or part of insurance


premium excess. ITEM

J Management and staff, including administrative


staff. ITEM

K Works operatives. ITEM

Other insurances

L Insurance premium tax (IPT). ITEM

M Allowance for recovery of all or part of insurance


premium excess. ITEM

N Employer’s loss of liquidated damages. ITEM

P Latent defects cover. ITEM

Q Motor vehicles. ITEM

To Collection

Bill No. 1 - Page 23


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN CONTRACTOR'S COST ITEMS

Insurance, bonds, guarantees and warranties

Other insurances

A Other insurances. ITEM

Bonds

B Tender bonds (if applicable). ITEM

C Performance bonds. ITEM

Guarantees

D Parent company guarantees. ITEM

E Product guarantees, insurance backed. ITEM

Warranties

F Collateral warranties. ITEM

G Funder’s warranties. ITEM

H Purchaser’s and tenant’s warranties. ITEM

J Other warranties. ITEM

To Collection

Bill No. 1 - Page 24


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

COLLECTION

Bill 1 - General Requirements / Page No. 1

Bill 1 - General Requirements / Page No. 2

Bill 1 - General Requirements / Page No. 3

Bill 1 - General Requirements / Page No. 4

Bill 1 - General Requirements / Page No. 5

Bill 1 - General Requirements / Page No. 6

Bill 1 - General Requirements / Page No. 7

Bill 1 - General Requirements / Page No. 8

Bill 1 - General Requirements / Page No. 9

Bill 1 - General Requirements / Page No. 10

Bill 1 - General Requirements / Page No. 11

Bill 1 - General Requirements / Page No. 12

Bill 1 - General Requirements / Page No. 13

Bill 1 - General Requirements / Page No. 14

Bill 1 - General Requirements / Page No. 15

Bill 1 - General Requirements / Page No. 16

Bill 1 - General Requirements / Page No. 17

Bill 1 - General Requirements / Page No. 18

Bill 1 - General Requirements / Page No. 19

Bill 1 - General Requirements / Page No. 20

Bill 1 - General Requirements / Page No. 21

Bill 1 - General Requirements / Page No. 22

Bill 1 - General Requirements / Page No. 23

Bill 1 - General Requirements / Page No. 24

TO SUMMARY
Bill No. 1 - Page 1
Bill No. 2 MAIN HOTEL
MAIN CONTRACT
INTERCONTINENTAL RESORT HOTEL
RAK PROPERTIES

VOLUME 2 BILLs OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

PILING AND SHORING SYSTEM

Cutting or breaking away heads of piles to required


levels; cleaning and protecting the projecting steel
reinforcement; removing debris off site all
accordance with engineer design and requirement.

Piles (Site Wide)

A 500 dia bored pile 377 no

B 750 dia bored pile 809 no

C 750 dia bored sea wall pile 61 no

D 750 dia bored tension pile 55 no

To Collection

Bill No. 2 - Page 1


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

EARTHWORK

Earthwork including excavation in all materials,


backfilling, compaction and removal of surplus
excavated materials from site

A Generally 6474 m3

FILLING

Approved filling materials as shown on Drawings and as


Specification

B Generally 86320 m3

SURFACE PREPARATION

Anti-termite treatment

C Generally 21580 m2

To Collection

Bill No. 2 - Page 2


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

Collection

Bill No. 2 - Page 1

Bill No. 2 - Page 2

To Summary

Bill No. 2 - Page 3


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

POURED CONCRETE: SUBSTRUCTURE

Plain Cement Concrete; Mix Type 4; Blinded smooth


finish

Blinding

A 75 thick 21580 m2

Reinforced Concrete, Mix Type 1

Pile caps, ground beams or the like

B Ground Beams 1328 m3

Pile caps

C 450 thick 6 m3

D 900 thick 27 m3

E 1000 thick 735 m3

F 1400 thick 2203 m3

Raft Foundation

G 300 thick 319 m3

H 350 thick 107 m3

Reinforced Concrete, Mix Type 4; Blended smooth


finish

Blinding

J 50 thick 21580 m2

POURED CONCRETE: SUPERSTRUCTURE

Reinforced Concrete, Mix Type 1

K Swimming pool slab 130 m3

L Swimming pool wall 45 m3

To Collection

Bill No. 2 - Page 4


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

POURED CONCRETE: SUPERSTRUCTURE

Reinforced Concrete, Mix Type 2

A Slabs 11919 m3

B Beams 7656 m3

C Stairs and landings 135 m3

Reinforced Concrete, Mix Type 3

D Columns 2815 m3

E Walls 5434 m3

REINFORCEMENT: SUBSTRUCTURE

High grade steel deformed bars including rolling


margin, supports, spacers; all diameters;
reinforcement in accordance with the information on
the drawings, specifications and subsequent
instructions

F Pile caps 341717 kg

G Tie beams 427945 kg

H Raft foundation 28172 kg

REINFORCEMENT: SUPERSTRUCTURE

High grade steel deformed bars including rolling


margin, supports, spacers; all diameters;
reinforcement in accordance with the information on
the drawings, specifications and subsequent
instructions

J Columns 546097 kg

K Walls 596600 kg

L Slabs 1382022 kg

M Beams 1623119 kg

To Collection

Bill No. 2 - Page 5


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

REINFORCEMENT: SUPERSTRUCTURE

High grade steel deformed bars including rolling


margin, supports, spacers; all diameters;
reinforcement in accordance with the information on
the drawings, specifications and subsequent
instructions

A Stairs and landings 17400 kg

B Swimming pool slab 15100 kg

C Swimming pool wall 7742 kg

SHUTTERING: SUBSTRUCTURE

Temporary shuttering for cast in situ concrete;


smooth finish

D Sides of pile caps 723 m2

E Sides of Tie beams 5792 m2

F Sides of raft foundation 91 m2

SHUTTERING: SUPERSTRUCTURE

Temporary shuttering for cast in situ concrete;


smooth finish

G Sides of columns 48918 m2

H Sides and soffits slabs 76295 m2

J Sides and soffits of beams 42924 m2

K Sides of walls 26385 m2

L Stairs and landings, including treads, risers,


strings and sloping soffits 712 m2

M Sides of swimming pool wall 426 m2

To Collection

Bill No. 2 - Page 6


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

SUNDRIES

Generally

A Allow for Mechanical Area concrete pads


including shuttering, reinforcement, joints,
electrical works and the like 3863 m2

Expansion Joints; Including all fire seals, stainless


steel cover plates, as required; As per Dwg No.
5310/A/SD1/012

Walls

B Allowance for isolation joints, expansion joints


and the like 1925 m

Expansion Joints; Including all fire seals, stainless


steel cover plates, as required; As per Dwg No.
5310/A/SD1/013

External Walls

C Allowance for isolation joints, expansion joints


and the like 1283 m

Expansion Joints; Including all fire seals, stainless


steel cover plates, as required; As per Dwg No.
5310/A/SD1/014

Slabs

D Allowance for isolation joints, expansion joints


and the like Item

Expansion Joints; Including all fire barriers,


aluminium finishes, as required; As per Dwg No.
5310/A/SD1/016-17

Floors

E Allowance for isolation joints, expansion joints


and the like 6944 m

To Collection

Bill No. 2 - Page 7


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

SUNDRIES

A Item deleted

Concrete beams and posts As per Drawing No.5310-A-


SD10-003

B Allow for concrete beams and posts (to


Blockwork) Item

To Collection

Bill No. 2 - Page 8


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

Collection

Bill No. 2 - Page 4

Bill No. 2 - Page 5

Bill No. 2 - Page 6

Bill No. 2 - Page 7

Bill No. 2 - Page 8

To Summary

Bill No. 2 - Page 9


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION D - MASONRY

WALLS AND PIERS

Block Work; bedded and jointed in cement mortar


including ties, bed, joints, head restraining systems,
vertical and base, joints, filler, fire and sound
stopping, sealant and grouting

Pre Insulated Block Work

A 250 thick; Type 1 1837 m2

Dense Hollow Block Work

B 150 thick; Type 4 7376 m2

Light Weight AAC Block Work

C 100 thick; Type 5 2947 m2

Light Weight AAC Block Work; 2 x 100 block, 50


insulation

D 250 thick, overall; Type 2 11402 m2

Mid Weight AAC Block Work

E 200 thick; Type 3 9611 m2

External Block Work; bedded and jointed in cement


mortar including ties, bed, joints, head restraining
systems, vertical and base, joints, filler, fire and
sound stopping, sealant and grouting

Pre Insulated Block Work

F 250 thick; Type 1 13074 m2

Dense Hollow Block Work

G 150 thick; Type 4 242 m2

Light Weight AAC Block Work

H 100 thick; Type 5 398 m2

To Collection

Bill No. 2 - Page 10


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION D - MASONRY

WALLS AND PIERS

External Block Work; bedded and jointed in cement


mortar including ties, bed, joints, head restraining
systems, vertical and base, joints, filler, fire and
sound stopping, sealant and grouting

Light Weight AAC Block Work; 2 x 100 block, 50


insulation

A 250 thick, overall; Type 2 153 m2

Mid Weight AAC Block Work

B 200 thick; Type 3 957 m2

Fridge and Chiller Wall; As specified

Walls

C generally 333 m2

To Collection

Bill No. 2 - Page 11


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION D - MASONRY

Collection

Bill No. 2 - Page 10

Bill No. 2 - Page 11

To Summary

Bill No. 2 - Page 12


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION E - METALWORK

STRUCTURAL METALWORK

A Item deleted

Main Hotel Canopy; Including all necessary


structural requirements and panels for complete
installation, with all necessary finishes as required;
As per Dwg No. 5310/A/H/PL1/105

Canopy

B Steel canopy approximate size 12000 x 12000 Item

Perforated Aluminium Sheets; finish as specified;


complete with all fixings (for canopy structure),
angles, abutments, closures, flashings, sealant,
membranes; As per Dwg No. 5310/A/H/D/214/975

Canopy

C D15; 5mm thick 207 m2

D D26; 750 x 750 x 5mm 624 m2

NON - STRUCTURAL METALWORK

Aluminium Composite Panels; Including all fixings,


angles, abutments, closures, flashings, sealant,
insulation, membranes, associated secondary
structural steel support, bracing, stiffeners as
required

Walls

E W3 352 m2

To Collection

Bill No. 2 - Page 13


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION E - METALWORK

NON - STRUCTURAL METALWORK

Aluminium Louvre Fins 100 x 100 x 5 Super durable


coating finish ; Including all fixings, angles,
abutments, closures, flashings, sealant, insulation,
membranes, associated secondary structural steel
support, bracing, stiffeners as required

Generally

A Feature Presidential Wing Level 01 Item

B Feature Presidential Wing Level 04 Item

C Feature Block F Roof LEvel Section RR drawing


312 Item

Hand Rail System; fixing to concrete with anchors,


including all glazing, fixtures, stainless steel hand rail
and finishes as required; As per Dwg No.
5310/A/SD1/020

Balustrades and Handrails

D 1100 overall 3799 m

E Item deleted

Metal mesh;

Ceilings

F C9 74 m2

Ladders; including plates, angles, bolts, plinths etc

Generally

G Cat ladder; galvanised steel; 2.1 m approx


height; 400 mm approx width; location - pool
plant rooms; refer to drawing 5310/A/SD11/071 10 no

H Cat ladder; galvanised steel; 2.3 m approx


height; 400 mm approx width; location - lift pits;
refer to drawing 5310/A/SD11/016 12 no

To Collection

Bill No. 2 - Page 14


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION E - METALWORK

NON - STRUCTURAL METALWORK

Ladders; including plates, angles, bolts, plinths etc

Generally

A Cat ladder; galvanised steel; 4.4 m approx height;


400 mm approx width; location - main hotel
from L02 to plantroom; refer to drawing
5310/A/SD11/071 2 no

B Cat ladder; galvanised steel; 3.1 m approx height;


400 mm approx width; location - main hotel
grease interceptor; refer to drawing
5310/A/SD11/071 1 no

C Cat ladder; stainless steel; 2.25 - 4m approx height;


450 mm approx width; location - water tanks;
refer to drawing 5310/A/SD11/001 - 002 12 no

D Cat ladder; stainless steel; 3 m approx height; location -


internal access stairs (L6 AHU room to roof); refer to
drawing 5310/A/SD11/070 2 no

E Cat ladder; stainless steel; 4 - 5 m approx


height; location - external access ladders; refer
to drawing 5310/A/SD11/017 - 018 - TBC 5 no

Stairs; including handrails, plates, angles, bolts,


plinths etc

Generally

F Staircase; galvanised steel; 3 m approx height;


510 mm approx width; location - roof access;
refer to drawing 5310/A/SD11/070 2 no

G Item Deleted

H Item Deleted

To Collection

Bill No. 2 - Page 15


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION E - METALWORK

NON - STRUCTURAL METALWORK

Corner guards; rubber; 50 x 50 x 1000mm angle;


refer to drawing 5310-A-SD11-091

A corner guards 675 no

Corner guards; stainless steel extrusion; 50 x 50 x 2000mm


angle; refer to drawing 5310-A-SD11-132

B Corner guards 462 no

Wall protection; rubber; 1520 wide plate


mounted on I beam bracket; refer to drawing
5310-A-SD11-011

C Wall protection barriers 1327 m

Wall protection crash rail; stainless steel; 152mm wide plate


mounted on mounting bracket; refer to drawing
5310-A-SD11-131

D Wall protection barriers 1389 m

Wall guard; 150mm wide vinyl or rigid cover mounted on


continuos aluminium retainer ; refer to drawing
5310-A-SD11-131

E Wall guard 940 m

Ballustrades and Handrails; Fixed to wall, steel


handrail including all brackets, caps and finishes as
required; As per Dwg No. 5310/A/SD2/001-2

Balustrades and Handrails

F 50 dia 591 m

Ballustrades and Handrails; Fixed to wall, steel


handrail including all brackets, rods, flanges, caps
and finishes as required; As per Dwg No.
5310/A/SD2/003

Balustrades and Handrails

G 920mm height 293 m

To Collection

Bill No. 2 - Page 16


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION E - METALWORK

Collection

Bill No. 2 - Page 13

Bill No. 2 - Page 14

Bill No. 2 - Page 15

Bill No. 2 - Page 16

To Summary

Bill No. 2 - Page 17


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION F - WOODWORK

STRUCTURAL TIMBERS

Glulaminated Wooden Thermoplastic Pergola; Including


all necessary fixings and finishes as required

Floor and flat roof members

A D7 - 2650 wide 136 m

Timber Cladding; Linings to columns; Including all


necessary fixings and finishes as required; As per
Dwg No. 5310/A/H/E/214

Timber Cladding

B D16 - 4500 high 14 no

Timber Cladding; Linings to columns; Including all


necessary fixings and finishes as required; As per
Dwg No. 5310/A/H/E/204

Timber Cladding

C D5 - 4000 high 27 no

Feature wall; Wooden thermoplastic polymer hollow


section feature wall to wooden pergola as per Dwg No.
5310/A/H/D/900 & 902

Feature wall

D D6; 2050mm long x 2600mm high 48 no

E D6; 3050mm long x 2600mm high 12 no

F D6; 800mm long x 2600mm high 12 no

G D6; 1900mm long x 6700mm high 4 no

H D6; 1000mm long x 6700mm high 2 no

To Summary

Bill No. 2 - Page 18


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION G - THERMAL AND MOISTURE
PROTECTION

WATERPROOFING

Waterproofing; To horizontal and vertical surfaces

Pile Caps

A 500 dia pile 747 no

B 750 dia pile 611 no

Waterproofing; 5 mm thick SBS waterproof


membrane including all fillers, abutments, angles,
working around obstructions and the like

Raft, Slabs and the like

C Horizontally 23148 m2

Raft, Walls, Slabs and the like

D Vertically 6415 m2

Roof slab waterproofing

E Horizontally 10649 m2

Balcony waterproofing

F Horizontally 2197 m2

Swimming Pool waterproofing

G Horizontally 330 m2

H Vertically 443 m2

1 coat of bituminous primer as Dwg No: 5310/A/SD1/019

J Horizontally 2156 m2

Wet area waterproofing as Dwg No: 5310/A/SD0/001

K Horizontally 2465 m2

L Vertically 5409 m2

To Collection

Bill No. 2 - Page 19


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION G - THERMAL AND MOISTURE
PROTECTION

WATERPROOFING

Mechanical rooms waterproofing as Dwg No: 5310/A/SD0/001

A Horizontally 203 m2

B Vertically 424 m2

5 mm thick torch applied bituminous waterproofing


as Dwg No: 5310/A/SD01/001

Service rooms

C Horizontally 655 m2

D Vertically 374 m2

Light weight screed waterproofing

Roof waterproofing; 30-110 mm thick

E Horizontally 10649 m2

Balcony waterproofing; 30-50 mm thick

F Horizontally 2197 m2

Swimming Pool waterproofing; 50 mm thick

G Horizontally 415 m2

Service room waterproofing; 50 mm thick

H Horizontally 655 m2

Cementitious waterproofing

Swimming Pool waterproofing

J Horizontally 220 m2

K Vertically 291 m2

Water Tank waterproofing

J Horizontally 688 m2

K Vertically 1832 m2

To Collection

Bill No. 2 - Page 20


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION G - THERMAL AND MOISTURE
PROTECTION

WATERPROOFING

Cement sand fillet

Roof waterproofing

A Horizontally 2862 m

Balcony waterproofing

B Horizontally 3250 m

Polythene Sheet

Coverings to insulation

C Flat 12642 m2

100 micron polythene sheet

Roof waterproofing

D Horizontal 10649 m2

Balcony waterproofing

E Horizontal 2197 m2

Super Durable PC Fin: Roof panels 750 wide x 1500


long, 5 open joint supported on pedestals,

Overlaid Coverings

F Flat 1457 m2

GRP lining

Water Tank waterproofing

G Horizontally 763 m2

H Vertically 1940 m2

To Collection

Bill No. 2 - Page 21


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION G - THERMAL AND MOISTURE
PROTECTION

INSULATION

Insulation; 60 mm thick rigid

Roof waterproofing

A Horizontal 10649 m2

Insulation; 20 mm thick rigid

Balcony waterproofing

B Horizontal 2197 m2

50 mm thick polystrene insulation as Dwg No: 5310/A/SD0/003

Floor

C Horizontal 10305 m2

Ceiling

D Horizontal 10305 m2

Aluminium Flashing

Roofs

E Generally 3301 m2

To Collection

Bill No. 2 - Page 22


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION G - THERMAL AND MOISTURE PROTECTION

Collection

Bill No. 2 - Page 19

Bill No. 2 - Page 20

Bill No. 2 - Page 21

Bill No. 2 - Page 22

To Summary

Bill No. 2 - Page 23


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

DOORS

Timber; Including wood frames, fixings, finishing,


sealants and leaf and frame finish

Internal Doors

Doors; 60 min fire rated

A D-01; 750 x 2200 17 no

B D-01; 850 x 2200 2 no

C D-01; 900 x 2125 76 no

D D-01; 950 x 2200 347 no

E D-01; 1000 x 2200 1 no

F D-01; 1050 x 2200 1 no

G D-02; 850 x 2200 1 no

H D-02; 950 x 2200 3 no

J D-03; 1550 x 2200 2 no

K D-03; 1600 x 2200 2 no

L D-03; 1650 x 2200 3 no

M D-03; 1950 x 2200 2 no

N D-04; 1650 x 2200 1 no

P D-05; 1450 x 2200 28 no

Q D-14; 950 x 2200 3 no

R D-15; 1000 x 2200 1 no

S 900 x 2200 2 no

T 950 x 2200 4 no

U 1000 x 2200 1 no

V 1100 x 2200 1 no

W 1450 x 2197 1 no

X 1525 x 2200 1 no

Y 1950 x 2200 1 no
To Collection

Bill No. 2 - Page 24


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

DOORS

Timber; Including wood frames, fixings, finishing,


sealants and leaf and frame finish

Internal Doors

Doors

A D-01; 750 x 2200 9 no

B D-01; 950 x 2200 18 no

C D-01; 1200 x 2200 1 no

D D-01; 1250 x 2925 1 no

E D-02; 950 x 2200 4 no

F D-03; 1450 x 2200 1 no

G D-04; 1600 x 2200 3 no

H D-04; 1650 x 2200 1 no

J D-05; 1450 x 2200 10 no

K D-05b; 1450 x 2200 1 no

L D-14; 950 x 2200 46 no

M D-14; 1000 x 2200 2 no

N 650 x 2200 2 no

P 750 x 2200 3 no

Q 750 x 2155 3 no

R 850 x 2155 1 no

S 850 x 2200 24 no

T 850 x 2825 1 no

To Collection

Bill No. 2 - Page 25


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

DOORS

Timber; Including wood frames, fixings, finishing,


sealants and leaf and frame finish

Internal Doors

Doors

A 850 x 2725 1 no

B 900 x 2200 11 no

C 900 x 2611 2 no

D 950 x 2200 21 no

E 1150 x 2155 1 no

F 1525 x 2200 1 no

G 1600 x 2200 1 no

H 1850 x 2200 1 no

J 1950 x 2925 3 no

K D-C02/042-01 1 no

L D-A02/090-01 1 no

Sliding Doors

M D-15; 850 x 2200 1 no

N D-15; 1000 x 2200 2 no

To Collection

Bill No. 2 - Page 26


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

DOORS

Steel door; Including metal frames, fixings,


finishings, sealants and leaf finish

Internal Doors

Doors; 60 min fire rated

A D-01; 850 x 2200 8 no

B D-01; 950 x 2200 73 no

C D-01; 950 x 2325 1 no

D D-01; 1000 x 2200 1 no

E D-01; 1200 x 2200 4 no

F D-02; 850 x 2200 1 no

G D-02; 950 x 2200 4 no

H D-03; 1600 x 2200 3 no

J D-03; 1750 x 2200 7 no

K D-03; 1950 x 2200 15 no

L D-04; 1550 x 2200 1 no

M D-05; 1100 x 2200 2 no

N D-05; 1450 x 2200 4 no

P D-05b; 1450 x 2200 6 no

Q D-06; 950 x 2200 3 no

R 1050 x 2200 2 no

Doors; 90 min fire rated

S D-01; 850 x 2200 4 no

T D-01; 950 x 2200 7 no

U D-01; 1000 x 2200 2 no

V D-01; 1200 x 2200 2 no

To Collection

Bill No. 2 - Page 27


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

DOORS

Steel door; Including metal frames, fixings,


finishings, sealants and leaf finish

Internal Doors

Doors; 90 min fire rated

A D-01; 1750 x 2200 1 no

B D-03; 1950 x 2200 5 no

C D-04; 1650 x 2200 1 no

D D-04; 1700 x 2200 2 no

E D-05; 1950 x 2925 1 no

F D-14; 950 x 2200 10 no

G D-14; 1000 x 2200 1 no

Doors

H D-01; 850 x 2200 5 no

J D-01; 950 x 2125 1 no

K D-01; 950 x 2200 22 no

L D-01; 950 x 2825 1 no

M D-01; 1200 x 2200 1 no

N D-01; 1950 x 2200 1 no

P D-02; 850 x 2200 2 no

Q D-02; 950 x 2200 22 no

R D-03; 1950 x 2325 1 no

S D-03; 1950 x 2775 1 no

T D-03; 1950 x 3025 1 no

U D-03; 1950 x 2125 1 no

To Collection

Bill No. 2 - Page 28


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

DOORS

Steel door; Including metal frames, fixings,


finishings, sealants and leaf finish

Internal Doors

Doors

A D-04; 1550 x 2200 3 no

B D-04; 1550 x 2225 1 no

C D-04; 1600 x 2200 5 no

D D-04; 1650 x 2200 1 no

E D-05; 1450 x 2200 2 no

F D-05b; 1450 x 2200 8 no

G D-14; 950 x 2200 1 no

H D-15; 950 x 2200 2 no

Aluminium door; Including metal frames, panels,


fixings finishings, sealants and leaf finish

Doors; 60 min fire rated

J 1050 x 2200 19 no

Doors

K D-01; 950 x 2350 4 no

L D-10; 2550 x 3025 3 no

M D-11; 2550 x 2775 3 no

N D-13; 950 x 1050 10 no

P 1050 x 2200 2 no

Sliding Doors

Q D-16 1 no

To Collection

Bill No. 2 - Page 29


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

DOORS

Glazed door; Including metal frames, fixings,


sealants and leaf finish

Internal Doors

Doors; 60 min fire rated

A D-08; 1650 x 2225 3 no

B D-09; 950 x 2825 1 no

Doors

C D-08; 1800 x 2325 2 no

D D-08; 1550 x 2200 7 no

E D-08; 1650 x 2825 1 no

F D-08; 1950 x 3425 1 no

G D-08; 1350 x 2925 1 no

H D-09; 950 x 2200 8 no

J D-09; 1000 x 2625 1 no

Sliding Doors

K D-15 3 no

External Pivot Doors

L D-19; 1700 x 2900 2 no

To Collection

Bill No. 2 - Page 30


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

DOORS

Roller shutter; Aluminium roller shutter including


framing to opening, all necessary roll up equipment,
accessories and finishes

Doors; 60 min fire rated

A D-17 1 no

B D-18; 4750 x 1375 1 no

Doors

C D-17 3 no

D D-18; 2400 x 1375 1 no

E D-18; 5000 x 1375 1 no

To Collection

Bill No. 2 - Page 31


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Skylights: Nominal Super durable coated Aluminium


sections type D, glazed as per the specifications
covered with 5mm thick perforated Aluminium
Screen in frames as indicated on drawings super
durable bronze colour metallic finish or equal to
Engineer's approval.

As Engineer details

C 2000 x 6500 to match D3 with 5 perforated


aluminium screen in frames - Executive Lounge 2 no

Bi Folding Door ; FSW-G or equal and approved to


the Engineers approval

Appropriate details

D 15300 x 3000 Ballroom Level 02 1 no

Aluminium framed fixed glazed window including


framing to opening, all necessary accessories,
finishes and ironmongeries

Windows

E 1050 x 1350 (Type W-1b) 1 no

F 450 x 2250 (Type W-1c) 4 no

G 450 x 3080 (Type W-1d) 26 no

H 450 x 2430 (Type W-1e) 7 no

J 450 x 2150 (Type W-1f) 1 no

K 1850 x 1850 (Type W-10) 9 no

To Collection

Bill No. 2 - Page 32


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed fixed glazed window including


framing to opening, all necessary accessories,
finishes and ironmongeries

Windows

A 8250 x 5000 (Type W-22) 2 no

B 1550 x 1050 (Type W-28b) 2 no

C 1150 x 1225 (Type W-30) 4 no

D 700 x 1225 (Type W-30b) 1 no

E 1250 x 1225 (Type W-30c) 10 no

F 1350 x 1225 (Type W-30f) 1 no

G 1600 x 1125 (Type W-30g) 1 no

H 1350 x 1225 (Type W-30h) 2 no

J Type W-30k 12 no

K 1450 x 1225 (Type W-30j) 12 no

L 450 x 2150 (Type W-1) 123 no

M 1000 x 1350 (Type W-1a) 6 no

To Collection

Bill No. 2 - Page 33


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed glazed panel including framing to


opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

A 3750 x 2150 (Type W-4) 4 no

B 4100 x 4450 (Type W-18) 2 no

C Type W-20b 1 no

D Type W-21 1 no

E 29525 x 2330 (Type W-106) 1 no

F 6800 x 2330 (Type W-107) 1 no

G 4100 x 2330 (Type W-108) 1 no

H 2275 x 2150 (Type W-109) 3 no

J 9195 x 2150 (Type W-110) 1 no

K 2550 x 2150 (Type W-112) 2 no

L 4495 x 2150 (Type W-113) 2 no

M 7992 x 2330 (Type W-114) 4 no

N 10250 x 2950 (Type W-115) 2 no

P 4225 x 2330 (Type W-116) 1 no

Q 4975 x 4450 (Type W-120) 1

R 1800 x 1250 (Type W-117) 10

S 1800 x 3580 (Type W-124) 1 no

T 3920 x 3580 (Type W-125) 1 no

U 8050 x 3580 (Type W-126) 1 no

To Collection

Bill No. 2 - Page 34


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed glazed panel including framing to


opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

A 5350 x 3580 (Type W-127) 1 no

B 2487 x 3580 (Type W-128) 2 no

C 5515 x 3580 (Type W-129) 1 no

D 4000 x 3580 (Type W-130) 1 no

E 7692 x 3580 (Type W-131) 1 no

F 8500 x 3580 (Type W-132) 2 no

G 1770 x 3580 (Type W-133) 1 no

J 2850 x 4250 (Type W-139) 2 no

K Type W-140 1 no

L 4950 x 3250 (Type W-141) 1 no

N 1200 x 3250 (Type W-150) 1 no

P 950 x 2020 (Type W-158) 2 no

Q 4900 x 3450 (Type W-54) 4 no

To Collection

Bill No. 2 - Page 35


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed glazed panel including framing to


opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

A 6150 x 3450 (Type W-53) 2 no

B 1100 x 850 (Type W-9) 3 no

C 1000 x 4450 (Type W-14) 1 no

D 1600 x 4450 (Type W-15) 1 no

E 4100 x 4450; angled (Type W-17) 1 no

F 2700 x 4450; angled (Type W-17a) 2 no

G Type W-19 1 no

H Type W-20 1 no

J Type W-20a 1 no

K 1050 x 1350; (Type W-17a) 2 no

L 2000 x 2850; (Type W-25) 1 no

M 3975 x 2750 (Type W-100) 1 no

N 3850 x 2750 (Type W-101) 7 no

P 1050 x 3350 (Type W-167) 2 no

Q 1200 x 2330 (Type W-171) 4 no

R 1350 x 2150 (Type W-172) 6 no

S 1300 x 2150 (Type W-173) 4 no

T 1300 x 2150 (Type W-174) 4 no

To Collection

Bill No. 2 - Page 36


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed glazed panel including framing to


opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

A 1350 x 2150 (Type W-175) 2 no

B 2275 x 2150 (Type W-176) 2 no

C 1245 x 2150 (Type W-177) 2 no

D 3365 x 2150 (Type W-178) 2 no

E 3740 x 2150 (Type W-179) 2 no

F 1550 x 2150 (Type W-180) 3 no

G 1750 x 2330 (Type W-181) 1 no

H 3675 x 3000 (Type W-182) 2 no

J 4450 x 2600 (Type W-201) 1 no

K 4450 x 2330 (Type W-202) 4 no

L 1550 x 2150 (Type W-203) 43 no

M 1550 x 2150 (Type W-203a) 8

N 1550 x 2150 (Type W-204a) 1 no

P 1550 x 2150 (Type W-204b) 1 no

Q 1550 x 2150 (Type W-205a) 1 no

R 4100 x 2150 (Type W-210) 329 no

S 8600 x 2150 (Type W-210a) 1 no

T 4100 x 2150 (Type W-211) 3 no

U Type W-212 5 no

V 4700 x 2900 (Type W-220) 2 no

To Collection

Bill No. 2 - Page 37


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed glazed panel consists of double


leaves glazed door in the middle and two equal fixed
panels on both sides including framing systems, all
necessary accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

A 3900 x 2750 (Type W-3) 1 no

B Type W-10a 1 no

Aluminium sliding door with fixed window frame glazed


panel including framing to opening,
all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

C 1750 x 3825 (Type W-23) 3 no

Aluminium door with fixed window frame glazed


panel including framing to opening,
all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

D 2350 x 3350 (Type W-105) 2 no

Aluminium spider glazed panel including framing to


opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

E 2350 x 3350 (Type W-164) 2 no

F 2350 x 3350 (Type W-164a) 1 no

G 2350 x 3350 (Type W-165) 2 no

H 2350 x 3350 (Type W-166) 2 no

To Collection

Bill No. 2 - Page 38


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed fixed glazed panel consists of a


combination of five equal fixed panels on both
sides, seven equal fixed top and bottom panels in
the middle, two single leaf glazed doors, equal and
unequal fixed panels on both side and top of the
door including framing to opening, all necessary
accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

A Item Deleted

Aluminium framed fixed glazed panel with two equal


fixed panels on top and bottom panel and top hung
window in the middle including framing to opening,
all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

B Item Deleted

Aluminium framed fixed glazed panel with two equal


fixed panels on top and bottom panel and top hung
window in the middle including framing to opening,
all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

C 6375 x 2600 (Type W-26) 1 no

Aluminium framed fixed glazed panel consists of


single leaf glazed door on one side and two equal
fixed panels on the other side including framing to
opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

D 3850 x 2750 (Type W-102) 1 no

To Collection

Bill No. 2 - Page 39


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed glazed panel consists of single


leaf door in the middle and two equal fixed panels on
both sides including framing to opening, all
necessary accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

A 2750 x 22750 (Type W-103) 1 no

B 3650 x 4600 (Type W-18c) 1 no

Aluminium framed glazed U-shaped panel consists


of two equal sides and one front side with two double
leaves glazed doors on both sides including framing
to opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

C SPIDER Glass in Panels size 14550 (U-shape) x


2400 x 3350 (Type W-104) 1 no

Aluminium framed glazed panel consists of double


leaves full swing door in the middle and two equal
fixed panels on both sides including framing to
opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

D 4750 x 3115 (Type W-111) 1 no

Aluminium framed glazed panel consists of one


double leaves full swing glazed door and a
combination of equal and unequal fixed panels in
different sizes on sides and top of the door including
framing to opening, all necessary accessories,
finishes and ironmongeries

Aluminium Framed Glazed Panels

E 2250 x 4450 (Type W-119) 1 no

To Collection

Bill No. 2 - Page 40


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed glazed panel consists of one


double leaves full swing glazed door and a
combination of equal and unequal fixed panels in
different sizes on sides and top of the door including
framing to opening, all necessary accessories,
finishes and ironmongeries

Aluminium Framed Glazed Panels

A Item Deleted

B Item Deleted

Aluminium framed glazed panel consists of one


double leaves full swing glazed door and a
combination of equal fixed panels on sides and
tops, one different size panel on top of the door
including framing to opening, all necessary
accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

C 4000 x 3580 (Type W-134) 1 no

Aluminium framed glazed panel consists of a


combination of three equal fixed panels, one unequal
fixed panels on top of the door and one single leaf
glazed door including framing to opening, all
necessary accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

D 2850 x 3350 (Type W-55) 4 no

To Collection

Bill No. 2 - Page 41


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed glazed panel consists of a


combination of equal and unequal fixed panels in
different sizes, three equal curved panels and
double leaves glazed full swing door including
framing to opening, all necessary accessories,
finishes and ironmongeries

Aluminium Framed Glazed Panels

A 6749 x 3580 (Type W-135) 1 no

Aluminium framed glazed panel consists of double


leaves door in the middle and two equal fixed panels
on both sides including framing to opening, all
necessary accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

B 2450 x 2250 (Type W-136) 1 no

Aluminium framed glazed panel consists of double


leaves full swing door in the middle, two equal fixed
panels on both sides and one panel on top of the
door including framing to opening, all necessary
accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

C 4635 x 3250 (Type W-137) 1 no

Aluminium framed glazed panel consists of double


leaves glazed door in the middle and one panel on
top of the door including framing to opening, all
necessary accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

E 2050 x 3250 (Type W-145) 1 no

To Collection

Bill No. 2 - Page 42


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed glazed panels consists of three


equal fixed panels on one side, one double leaves
full swing glazed door on the other side and one
fixed panel on top of the door including framing to
opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

A 8195 x 3250 including Bi Fold doors (Type 1 no


W-147)

B 7950 x 3250 including Bi Fold doors (Type


W-149) 1 no

C 9805 x 3250 (Type W-146) 1 no

D 3850 x 4250 including Bi Fold doors (Type


W-148) 1 no

Aluminium framed glazed panel consists of single


leaf full swing glazed door in the middle, two equal
fixed panels on both sides and one unequal panel on
top of the door including framing to opening, all
necessary accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

E Item Deleted

Aluminium framed glazed panel consists of single


leaf glazed door and one panel on top of the door
and one panel on top of the door including framing to
opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

F 1350 x 4450 (Type W-157) 1 no

To Collection

Bill No. 2 - Page 43


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed glazed panels consists of seven


unequal fixed panels, made up of two equal fixed
panels, three other equal fixed panels and two other
equal curved fixed panels and one single leaf
glazed door including framing to opening, all
necessary accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

A 2800 + 5900 + 3770mm (curved) x 2480 Type


W-160) 5 no

Aluminium framed glazed panel consists of double


leaves full swing glazed door in the middle and equal
fixed panels on both sides including framing to
opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

B Type W-163 1 no

Aluminium framed louvered panels including framing


to opening, all necessary accessories and finishes

Louvred Panels

C 2500 x 650 (Type L-36) 1 no

D 5950 x 650 (Type L-37) 1 no

To Collection

Bill No. 2 - Page 44


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed louvered panels including framing


to opening, all necessary accessories and finishes

Louvred Panels

A 6850 x 650 (Type L-38) 1 no

B 900 x 700 (Type L-39) 1 no

C 2700 x 2200 (Type L-40) 1 no

D 8850 x 800 (Type L-41) 1 no

E 1200 x 1200 (Type L-01) 2 no

F 2050 x 2250 (Type L-02) 1 no

G 2100 x 500 (Type L-36) 1 no

H 1150 x 2250 (Type L-03) 1 no

J 3500 x 3750 (Type L-05) 2 no

K 1800 x 2750 (Type L-07) 1 no

L 1950 x 2750 (Type L-08) 1 no

M 1800 x 2300 (Type L-10) 15 no

N 1250 x 1550 (Type L-14) 3 no

P 1250 x 2950 (Type L-15) 2 no

Q 1500 x 1850 (Type L-21) 1 no

R 2100 x 950 (Type L-22) 1 no

To Collection

Bill No. 2 - Page 45


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed louvered panels consists of two


equal panels including framing to opening, all
necessary accessories

Louvred Panels

A 4700 x 2750 (Type L-04) 1 no

B 2600 x 2600 (Type L-16) 1 no

C 2600 x 650 (Type L-19) 5 no

D 4300 x 1850 (Type L-20) 1 no

E 3900 x 950 (Type L-23) 3 no

F 3550 x 2700 (Type L-26) 2 no

Aluminium framed louvered panels consists of


non-louvered panel at the bottom and louvered panel
on top including framing to opening and all
necessary accessories and finishes

Louvred Panels

G 3800 x 2350 (Type L-06) 1 no

H 1825 x 2350 (Type L-09) 1 no

Aluminium framed louvered panels consists of four


equal panels, including framing to opening and all
necessary accessories and finishes

Louvred Panels

J 6000 x 2700 (Type L-29) 1 no

K 6150 x 2700 (Type L-30) 1 no

L 6000 x 2700 (Type L-32) 1 no

M 5125 x 2700 (Type L-24) 2 no

To Collection

Bill No. 2 - Page 46


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

WINDOWS

Aluminium framed louvered panels consists of four


equal panels, including framing to opening and all
necessary accessories and finishes

Louvred Panels

A 6000 x 2700 (Type L-27) 1 no

Aluminium framed louvered panels consists of six


equal panels, including framing to opening and all
necessary accessories and finishes

Louvred Panels

B 9000 x 2700 (Type L-25) 2 no

C 8550 x 2700 (Type L-28) 1 no

Aluminium framed louvered panels consists of one


double aluminium louvered door, two fixed panel on
top of the door and two equal panels on the side
including framing to opening, all necessary
accessories, finishes and ironmongeries

Louvred Panels

D 6035 x 1000 (Type L-31) 1 no

Aluminium framed louvered panels consists of two


double panels aluminium louvered folding door, two
fixed panel on top of the door and two equal panels
on the side including framing to opening, all
necessary accessories, finishes and ironmongeries

Louvred Panels

E 5480 x 2700 (Type L-33) 2 no

To Collection

Bill No. 2 - Page 47


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

Collection

Bill No. 2 - Page 24

Bill No. 2 - Page 25

Bill No. 2 - Page 26

Bill No. 2 - Page 27

Bill No. 2 - Page 28

Bill No. 2 - Page 29

Bill No. 2 - Page 30

Bill No. 2 - Page 31

Bill No. 2 - Page 32

Bill No. 2 - Page 33

Bill No. 2 - Page 34

Bill No. 2 - Page 35

Bill No. 2 - Page 36

Bill No. 2 - Page 37

Bill No. 2 - Page 38

Bill No. 2 - Page 39

Bill No. 2 - Page 40

Bill No. 2 - Page 41

Bill No. 2 - Page 42

Bill No. 2 - Page 43

Bill No. 2 - Page 44

Bill No. 2 - Page 45

Bill No. 2 - Page 46

Bill No. 2 - Page 47

To Summary

Bill No. 2 - Page 48


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

BACKGROUNDS (INTERNALLY)

Render; two coat work 18 mm thick

Walls

A W07 32904 m2

Floor Screed; to receive floor finishes as specified

B 40mm thick 5194 m2

BACKGROUNDS (EXTERNALLY)

Light weight screed

40 mm thick

C Floors; to falls, crossfalls and cambers 4631 m2

Render; two coat work 20 mm thick

Walls

A Roof 1609 m2

Cement Board; Comprising of 2 No. layers, including


all battons, linings, fixings, finishes; As per Dwg No.
5310/A/SD1/019

Soffit

D on ceilings 6662 m2

FINISHINGS (INTERNALLY)

Dividing Strips; 3mm stainless steel with lath,


beddings, and sealants as required; As per Dwg No.
5310A/SD9/001-005

Dividing Strips

E Generally 479 m

Carpet tiles; Including adhesives, trowelable levelling


and patching compound, edgings, gripper rods,
fixings
Floors

F F1 741 m2

To Collection

Bill No. 2 - Page 49


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (INTERNALLY)

Porcelain tiles; Including adhesives, trowelable


levelling and patching compound, edgings and fixings

Floors

A F2 505 m2

B F2 - Terraced areas 3985 m2

Walls

C W10 39 m2

Skirting

D S2; 150 high 2296 m

Ceramic tiles; Including adhesives, trowelable


levelling and patching compound, edgings and fixings

Floors

E F5 529 m2

Walls

F W02 1956 m2

Skirting

G S5; 100 high 848 m

Ceramic tiles; Anti-microbial, including adhesives,


trowelable levelling and patching compound, edgings
and fixings

Walls

H W05 4105 m2

To Collection

Bill No. 2 - Page 50


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (INTERNALLY)

Quarry tiles; Including adhesives, trowelable levelling


and patching compound, edgings and fixings

Floors

A F15 239 m2

Skirting

B S11; 100 high 386 m

Vinyl; Including adhesives, trowelable levelling and


patching compound, edgings and fixings

Floors

C F3 1903 m2

Skirting

D S4; 100 high 349 m

Vinyl coved; Including adhesives, trowelable levelling


and patching compound, edgings and fixings

Skirting

E S3 1563 m

Acrylic; Including one coat sealer, two coats paint

Walls

F W03 2450 m2

Epoxy; Including one coat sealer, two coats paint

Floors

G F4 6638 m2

To Collection

Bill No. 2 - Page 51


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (INTERNALLY)

Epoxy; Including one coat sealer, two coats paint

Floors

A F6 924 m2

Walls

B W08 10094 m2

Skirting

C S7 3565 m

D S8 2424 m

Epoxy: Incl. one sealer, two wetpaint

Staircase treads, risers, edges or the like

S6

E horizontal 137 m

Concrete sealer;

Floors

F F10 1602 m2

Hardwood; Solid timber

Skirting

G S1; 100 high 596 m

Car Park finishes system; Including all coatings,


lines, arrows, numbers and skirtings

Floors

H F8 12135 m2

To Collection

Bill No. 2 - Page 52


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (INTERNALLY)

Paint; Acrylic emulsion paint finish, including 1 no.


coat primer and 2 no. coat finish

Walls

A W01 19566 m2

B Terraced areas 6375 m2

Ceilings

C C1 2332 m2

D C8 41 m2

Paint; Anti-Carbonation; Including one coat sealer,


two coats undercoat, one coat anti-carbonation paint

Walls

E W06 3086 m2

Ceilings

F C11 11109 m2

GRP lining; Liquid applied, for Water Tanks

Floors

G F9 688 m2

Walls

H W09 1575 m2

Ceilings

J C10 687 m2

To Collection

Bill No. 2 - Page 53


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (INTERNALLY)

Tiles; Mineral fibre acoustic tiles, with revealed edge

Ceilings

A C4 45 m2

Tiles; Mineral fibre acoustic tiles, with exposed grid

Ceilings

B C6 5678 m2

Tiles; Metal tiles, with hard vinyl liner

Ceilings

C C5 597 m2

Exposed structure

Ceilings

D C12 4670 m2

Wall guards; high impact vinyl/acrylic; 2 layers

Walls

E generally 1481 m

Entrance matt; 'Gradus Esplanade 1500' or similar


approved by Engineer; colour tbc; including matwell
frame, aluminium finish

Floors

F generally 300 m2

Chiller and cold area finishes as per kitchen consultants


specification

G Floors 216 m2

H Walls 1348 m2

J Skirtings 269 m

K Ceilings 216 m2

To Collection

Bill No. 2 - Page 54


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (INTERNALLY)

Stair insert; 30mm Aluminium non slip metal insert, fixed


to stairs

Staircase treads, risers, edges or the like

A MS3 1448 m

FINISHINGS (EXTERNALLY)

Terrace tile;

Floors

B F13; to match as per drawing 179-DD-202 50 m2

Textured Acrylic Paint

Walls

C W1 23301 m2

Un-Textured Acrylic Paint

Walls

D W2 531 m2

Stone cladding; finish as specified; complete with all


fixings, angles, abutments, closures, flashings,
sealant, membranes 30 thick units; including all
associated rails, brackets, anchors as required

Walls

E Lime stone panel 1500x80x30mm 1152 m2

To Collection

Bill No. 2 - Page 55


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (EXTERNALLY)

Perforated Aluminium Screen; finish as specified;


complete with all fixings, angles, abutments,
closures, flashings, sealant, membranes; including
all associated rails, brackets, anchors as required

Walls

A D3; 5mm Aluminium screen 413 m2

B D8; 5mm Aluminium screen type 1 630 m2

C D9; 5mm Aluminium screen type 2 147 m2

D D24; 5mm Perforated aluminium screen on secondary


support 240 m2

Perforated Aluminium Nosing; finish as specified;


complete with all fixings, angles, abutments,
closures, flashings, sealant, membranes; including
all associated rails, brackets, anchors as required;
As per Dwg No. 5310/A/H/E/209

Roofs

E D19; 5mm Aluminium nosing 2087 m2

Aluminium Mesh; finish as specified; complete with


all fixings, angles, abutments, closures, flashings,
sealant, membranes

Walls

F D10; Aluminium mesh 360 m2

Perforated Aluminium Panel; finish as specified;


complete with all fixings, angles, abutments,
closures, flashings, sealant, membranes

Walls

G D18; Aluminium panel 750x1500x5mm 1905 m2

To Collection

Bill No. 2 - Page 56


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (EXTERNALLY)

Perforated Aluminium Screen; finish as specified;


complete with all fixings, angles, abutments,
closures, flashings, sealant, membranes

Walls

A D20; 5mm Perforated aluminium screen 134 m2

GRP Facia; finish as specified; complete with all


fixings, angles, abutments, closures, flashings,
sealant, membranes

Walls

B D2; Off white 10410 m2

Aggregate Ballast (Gravel)

Roofs

C F17 3170 m2

Concrete pavers

Roofs

D 600 x 600 x 50 pavers 3405 m2

Timber effect cladding; approx dimensions 40 x 50


mm; 'Woodn Versatilis' or similar approved by
Engineer

Walls

E generally 36 m2

Glass Reinforced Plastic; 250 x 500 Including all


fixings and finishes as required; As per Dwg No.
5310/A/H/E/204

Walls

F D1; 250x500x2450mm U shaped Post 400 no

To Collection

Bill No. 2 - Page 57


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

SUSPENDED CEILINGS (INTERNALLY)

A Item Deleted

To Collection

Bill No. 2 - Page 58


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

Collection

Bill No. 2 - Page 49

Bill No. 2 - Page 50

Bill No. 2 - Page 51

Bill No. 2 - Page 52

Bill No. 2 - Page 53

Bill No. 2 - Page 54

Bill No. 2 - Page 55

Bill No. 2 - Page 56

Bill No. 2 - Page 57

Bill No. 2 - Page 58

To Summary

Bill No. 2 - Page 59


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION K - ACCESSORIES

GENERALLY

A Item Deleted

Wheel Stopper; including finishes as required, fixed


as per manufacturer's instructions; As per Dwg No.
5310/A/SD11/090

Wheel Stoppers

B 2000 length 299 no

Directional arrows; painted on floor

Type A (Straight)

C 5000 overall length 1 no

Type B (Right Turn)

D 5000 overall length 1 no

Type C (Left Turn)

E 5000 overall length 1 no

Type D (Straight/Right)

F 5000 overall length 1 no

Type E (Straight/Left)

G 5000 overall length 1 no

Type F (Left/Right)

H 5000 overall length 1 no

To Collection

Bill No. 2 - Page 60


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION K - ACCESSORIES

GENERALLY

Speed Hump

Speed Hump; Fixed to floor as per manufacturer


written instructions; As per Dwg No.
5310/A/SD11/013

A 6000 length 1 no

Carpark Lines

Carpark Lines

B 75 wide 3791 no

Bollard

200mm Diameter galvanised iron pipes welded


together including painting stripes

C 5000 long x 1200 high (enclosed column) 6 no

D 4200 long x 1200 high (enclosed column) 1 no

E 3400 long x 1200 high (enclosed column) 1 no

F 12000 long x 1200 high 1 no

G 6000 long x 1200 high 11 no

H 5000 long x 1200 high 3 no

J 2000 long x 1200 high 1 no

200mm Diameter galvanised iron pipes single


bollard including painting stripes

K 1200 high 12 no

Loading Bay Bumper

Heavy duty rubber bumper

L 4000 long 3 no

To Collection

Bill No. 2 - Page 61


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION K - ACCESSORIES

GENERALLY

Loading Bay Bumper

Heavy duty rubber bumper

A 3000 long 1 no

B 800 long 6 no

Car Park Numbering

Epoxy road paint/Thermoplastic paint

C Overall grid size 300 x 300 299 no

Car Park Handicapped Sign

Epoxy road paint/Thermoplastic paint


D Overall grid size 900 x 900 8 no

Automatic Rising Kerb

PF8000 Automatic Rising Kerb; including control


panel, concrete plinths; As Dwg No. 5310/ASD11/72

E 3000 long 1 no

PARTITIONS

F Item Deleted

Urinal partitions: 350 x 1200 mm size, Plywood partition to


complete as per Drawing no. 5310/A/SD11/086

Partitioning

G generally 15 no

Bathroom Accessories
Supply and install all Sanitary Ware as shown on the
drawings and specified required for a complete installation
as indicated.

H Toilet paper holder 68 no

J Clothing hook 68 no

K Bathroom mirror Item

To Collection

Bill No. 2 - Page 62


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION K - ACCESSORIES

SIGNAGE AND WAYFINDING

Supply and install; Signage and wayfinding fixed to


walls, floors or ceilings including all necessary
associated works for a complete installation

A Back of House, BoH10 335 no

B Level Identification (BoH), BoH20 79 no

C BoH Facility Sign, BoH30 1 no

D BoH Facility Sign,Text & Picto, BoH31 3 no

E BOH Toilet Door Identification Sign, BoH32 12 no

F Comfirmatory/Entrance Area Identifier, CP10 3 no

G Advance Directional Suspended Sign, CP20 18 no

H Area Identifier Column ID, CP30 61 no

J Area Identifier @ Core Entrance, CP40 3 no

K Room Sign, RK10 341 no

L Area Identification Confirmational, RK20 20 no

M Advance Directional Wall Mounted, RK30 14 no

N Level Directional Wall Mounted, RK40 26 no

P Lift Lobby Identifier, RK50 22 no

Q Directory Sign, RK60 2 no

R Advance Directional Totem, RKP10 15 no

S Confirmatory Directional Sign, RKP30 12 no

T Area Identifier Sign, RKP40 21 no

U Advance Directional Municipality Sign, RKV10 3 no

V Site Identifier, RKV20 2 no

W Area Identifier, RKV30 2 no

X Welcome Sign, RKV40 1 no

Y Lift Warning Statutory Sign, SS10 56 no


To Collection

Bill No. 2 - Page 63


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION K - ACCESSORIES

SIGNAGE AND WAYFINDING

Supply and install; Signage and wayfinding fixed to


walls, floors or ceilings including all necessary
associated works for a complete installation

A Fire Evacuation Map Sign, SS20 320 no

B Fire Exit Statutory Sign, SS30 7 no

C Keep Clear Statutory Sign, SS40 9 no

D Keep Clear Fire Exit Statutory Sign, SS50 69 no


.
E Pool Rules and Regulations Sign, SS70 4 no

F Beach Rules and Regulations Sign, SS71 2 no

G Spa Rules & Regulation Sign, SS72 3 no

H Gym Rules & Regulation Sign, SS73 2 no

J Change & Lockers Rules & Regulation Sign, SS74 1 no

K Teen Club Rules & Regulation Sign, SS75 1 no

To Collection

Bill No. 2 - Page 64


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION K - ACCESSORIES

Collection

Bill No. 2 - Page 60

Bill No. 2 - Page 61

Bill No. 2 - Page 62

Bill No. 2 - Page 63

Bill No. 2 - Page 64

To Summary

Bill No. 2 - Page 65


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION L - EQUIPMENT

FALL ARREST / ANCHORING SYSTEMS

Specialist equipment

Anchor system

A 'Hilti Mechanical Anchoring System' or similar;


brackets, frame, fixing, and bolts system; all
corrosion resistant stainless steel for mechanical
stone vertical and ceiling fixations; to provide a
three dimensional flexibility through adjusting
connection method, adjustable arm threaded rod
with flat end, fixed to a captive hexagonal nut,
and dowel pin with fixed washer; all to engineers
approval 1 Item

Facade access system

B 'Rostek Rope Access Eyebolt Anchors' abseil


system or similar; stainless steel; roof mounted;
D-Rings in pairs at 1500 c/c; optimal spacing
between eyebolts; padding to be used for
parapet capping protection; provide access to all
facades; all to engineers approval 1 Item

Fall protection system

C 'Rostek-UK Horizontal Lifeline Systems or


similar; fixed to roof structure with force
management technology by using special GMS
metal roof sheets and roofing substrates as
structural anchors (as per suppliers technical
requirements); 8 mm steel wire based including
end anchors, intermediate, and corner cable
supports spacing at 10 m max, to allow
maximum flexibility in system designs and
ensure workers have uncompromised access for
all aspects of roof inspection and maintenance;
to be provided at all locations when difference in
level is 1.5 m or more, where parapet height is
less than 1.1 m from roof FFL; all to engineers
approval 1 Item

To Collection

Bill No. 2 - Page 66


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION L - EQUIPMENT

Collection

Bill No. 2 - Page 66

To Summary

Bill No. 2 - Page 67


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION M - FURNISHINGS

GENERALLY

Furniture

Generally

A Lockers; double doors; overall dimensions 400 x


400 x 1800; fully welded compartment lockers
0.7 mm MS, finished with epoxy powder paint
coat 406 no

B Shelving units, 5 nr shelves, 600 mm deep 127 m

Vanity top; granite; cut outs for 4 no basins (basins


C measured seperately) 4 m

Vanity top; granite; cut outs for 7 no basins (basins


D measured seperately) 5 m

To Summary

Bill No. 2 - Page 68


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION P - CONVEYING SYSTEMS

LIFT INSTALLATION

Lift Installation; Public lift for low zone rise passenger


elevators, 1275 kg capacity, speed 1.75 MPS,
servicing 2 no. floors, as per specifications and
drawings

Public Lift

A PL-01 1 no

Lift Installation; Public lift for low zone rise passenger


elevators, 1600 kg capacity, speed 1.75 MPS,
servicing 7 no. floors, as per specifications and
drawings

Public Lift

B PL-02 1 no

C PL-03 1 no

D PL-04 1 no

E PL-07 1 no

F PL-08 1 no

Public/Firemans Lift

G PL-09 1 no

Lift Installation; Public lift for low zone rise passenger


elevators, 1600 kg capacity, speed 1.75 MPS,
servicing 3 no. floors, as per specifications and
drawings

Public Lift

H PL-05 1 no

J PL-06 1 no

To Collection

Bill No. 2 - Page 69


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION P - CONVEYING SYSTEMS

LIFT INSTALLATION

Lift Installation; Service lift for low zone rise


passenger elevators, 800-1000 kg capacity, speed
1.75 MPS, servicing 2 no. floors, as per
specifications and drawings

Service Lift

A SL-01 1 no

B SL-02 1 no

Lift Installation; Service lift for low zone rise


passenger elevators, 1000-1150 kg capacity, speed
1.75 MPS, servicing 2 no. floors, as per
specifications and drawings

Service Lift

C SL-03 1 no

Lift Installation; Service lift for low zone rise


passenger elevators, 1600 kg capacity, speed 1.75
MPS, servicing 8 no. floors, as per specifications
and drawings

Service/Firemans Lift

D SL-04 1 no

E SL-05 1 no

Lift Installation; Service lift for low zone rise


passenger elevators, 1000-1275 kg capacity, speed
1.75 MPS, servicing 8 no. floors, as per
specifications and drawings

Service Lift

F SL-06 1 no

To Collection

Bill No. 2 - Page 70


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION P - CONVEYING SYSTEMS

LIFT INSTALLATION

Lift Installation; Service lift for low zone rise


passenger elevators, 1800 kg capacity, speed 1.75
MPS, servicing 7 no. floors, as per specifications
and drawings

Service/Firemans Lift

A SL-08 1 no

B SL-09 1 no

Sundries

Generally

C Identification, which shall include plates, discs,


labels, charts and colour coding Item

D Testing and commissioning, which shall include


operating completed installations and providing
fuel and power Item

E Tools and spares, which shall include loose keys


and consumable stores Item

F Documents, which shall include drawings,


operating instructions and maintenance manuals Item

G Supports, which shall include fixings, anchors,


insulating blocks and anti-vibration devices Item

Work incidental to conveying systems

Generally

H Coordinating with other engineering installations Item

J Cutting or forming holes, mortices, chases or the


like and making good as required Item

K Building in or cutting and pinning brackets or the


like and making good as required Item

To Collection

Bill No. 2 - Page 71


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION P - CONVEYING SYSTEMS

LIFT INSTALLATION

Work incidental to conveying systems

Generally

A Cleaning and polishing exposed surfaces Item

To Collection

Bill No. 2 - Page 72


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION P - CONVEYING SYSTEMS

Collection

Bill No. 2 - Page 69

Bill No. 2 - Page 70

Bill No. 2 - Page 71

Bill No. 2 - Page 72

To Summary

Bill No. 2 - Page 73


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

RAINWATER INSTALLATION

Gutter work; cast iron

Generally

A cast iron grating; 300 wide; refer to drawing


5310 A-H-PL00-103 379 m

To Summary

Bill No. 2 - Page 74


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION AMOUNT AED

Summary

SECTION B - SITE WORKS Bill No. 2 - Page 3

SECTION C - CONCRETE Bill No. 2 - Page 9

SECTION D - MASONRY Bill No. 2 - Page 12

SECTION E - METALWORK Bill No. 2 - Page 17

SECTION F - WOODWORK Bill No. 2 - Page 18

SECTION G - THERMAL AND MOISTURE Bill No. 2 - Page 23

SECTION H - DOORS AND WINDOWS Bill No. 2 - Page 48

SECTION J - FINISHES Bill No. 2 - Page 59

SECTION K - ACCESSORIES Bill No. 2 - Page 65

SECTION L - EQUIPMENT Bill No. 2 - Page 67

SECTION M - FURNISHINGS Bill No. 2 - Page 68

SECTION P - CONVEYING SYSTEMS Bill No. 2 - Page 73

SECTION Q - MECHANICAL ENGINEERING SYSTEMS Bill No. 2 - Page 74

To General Summary

Bill No. 2 - Page 75


Bill No. 3 VILLAS AND CHALETS
MAIN CONTRACT
INTERCONTINENTAL RESORT HOTEL
RAK PROPERTIES

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

EARTHWORK

Earthwork including excavation in all materials,


backfilling, compaction and removal of surplus
excavated materials from site

A Generally 1159 m3

FILLING

Approved filling materials as shown on Drawings and as


Specification

B Generally 2704 m3

SURFACE PREPARATION

Anti-termite treatment

C Generally 3863 m2

To Summary

Bill No. 3 - Page 1


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

POURED CONCRETE: SUBSTRUCTURE

Plain Cement Concrete; Mix Type 4; Blinded


smooth finish

Blinding

A 75 thick 3863 m2

Reinforced Concrete, Mix Type 1

Raft Foundation

B 250 thick 111 m3

C 300 thick 1026 m3

Raft Thickening

D Generally 86 m3

Reinforced Concrete, Mix Type 4; Blended smooth


finish

Blinding

E 50 thick 3861 m2

Mass Concrete, as specified

Staircases, steps, strings or the like

F Light weight steps 45 m3

POURED CONCRETE: SUPERSTRUCTURE

Reinforced Concrete, Mix Type 1

G Walls 43 m3

Reinforced Concrete, Mix Type 2

H Slabs 641 m3

J Beams 382 m3

To Collection

Bill No. 3 - Page 2


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
POURED CONCRETE: SUPERSTRUCTURE

Reinforced Concrete, Mix Type 2

A Stairs and landings 88 m3

Reinforced Concrete, Mix Type 3

B Columns 239 m3

C Parapet walls 127 m3

REINFORCEMENT: SUBSTRUCTURE

High grade steel deformed bars including rolling


margin, supports, spacers; all diameters;
reinforcement in accordance with the information
on the drawings, specifications and subsequent
instructions

D Raft foundation 92452 kg

REINFORCEMENT: SUPERSTRUCTURE

High grade steel deformed bars including rolling


margin, supports, spacers; all diameters;
reinforcement in accordance with the information
on the drawings, specifications and subsequent
instructions

E Columns 45658 kg

F Walls 3810 kg

G Slabs 60675 kg

H Beams 56885 kg

J Parapet walls 13514 kg

SHUTTERING: SUBSTRUCTURE

Temporary shuttering for cast in situ concrete;


smooth finish

K Sides of raft foundation 379 m2

To Collection

Bill No. 3 - Page 3


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SHUTTERING: SUBSTRUCTURE

Temporary shuttering for cast in situ concrete;


smooth finish

A Sides of raft thickening 210 m2

SHUTTERING: SUPERSTRUCTURE

Temporary shuttering for cast in situ concrete;


smooth finish

B Sides of columns 3340 m2

C Sides and soffits slabs 3651 m2

D Sides and soffits of beams 2753 m2

E Sides of walls 281 m2

F Sides of parapet walls 1267 m2

G Stairs and landings, including treads, risers, strings


and sloping soffits 255 m2

To Collection

Bill No. 3 - Page 4


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

Collection

Bill No. 3 - Page 2

Bill No. 3 - Page 3

Bill No. 3 - Page 4

To Summary

Bill No. 3 - Page 5


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION D - MASONRY

WALLS AND PIERS

Block Work; bedded and jointed in cement mortar


including ties, bed, joints, head restraining systems,
vertical and base, joints, filler, fire and sound
stopping, sealant and grouting

Pre Insulated Block Work

A 250 thick; Type 1 5605 m2

Dense Hollow Block Work

B 150 thick; Type 4 2805 m2

Light Weight AAC Block Work

C 100 thick; Type 5 765 m2

Mid Weight AAC Block Work

D 200 thick; Type 3 288 m2

To Summary

Bill No. 3 - Page 6


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION E - METALWORK

NON - STRUCTURAL METALWORK

Steel gate; Including all fixtures, finishes and fittings


necessary for complete installation

Gates

A D-74; 2800 x 3250 16 no

Ballustrades and Handrails; Fixed to wall, steel


handrail including all brackets, caps and finishes as
required; As per Dwg No. 5310/A/SD2/001-2

Balustrades and Handrails

B 50 dia 328 m

Wooden Thermoplastic polymer hollow section


composite featuring; Including all necessary fixings and
finishes as required

Pergola

C Nominal size type 3 19 m2

To Summary

Bill No. 3 - Page 7


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION G - THERMAL AND
MOISTURE PROTECTION

WATERPROOFING

Waterproofing; 5 mm thick SBS waterproof


membrane including all fillers, abutments, angles,
working around obstructions and the like

Raft, Slabs and the like

A Horizontally 3863 m2

B Vertically 345 m2

COVERINGS AND LININGS

Polythene Sheet

Coverings to insulation

C flat 3863 m2

Typical concrete paving tiles/aggregate roofing

Overlaid Coverings

D Flat 3863 m2

INSULATION

Insulation; Rigid

Generally

E flat 3863 m2

To Summary

Bill No. 3 - Page 8


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

DOORS

Timber; Including wood frames, fixings, finishing,


sealants and leaf and frame finish

External Doors

A D-41; 1130 x 2515 32 no

Glazed door; Including metal frames, fixings,


sealants and leaf finish

External Sliding Doors

B 4150 x 2850 (Type W-36b) 32 no

WINDOWS

Skylights: Nominal Super durable coated


Aluminium sections type D, glazed as per the
specifications covered with 5mm thick perforated
Aluminium Screen in frames as indicated on
drawings super durable bronze colour metallic
finish or equal to Engineer's approval.

As Engineer details

C Item Deleted

D Item Deleted

Aluminium framed fixed glazed window including


framing to opening, all necessary accessories,
finishes and ironmongeries

Aluminium Windows

E 795 x 1950 (Type W-38c) 5 no

F 1150 x 1600 (Type W-35) 64 no

G 795 x 2925 (Type W-38) 5 no

To Collection

Bill No. 3 - Page 9


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
WINDOWS

Aluminium framed fixed glazed window including


framing to opening, all necessary accessories,
finishes and ironmongeries

Aluminium Windows

A 1245 x 1950 (Type W-38b) 5 no

SCREENS

Aluminium framed glazed panel consists of three


equal fixed panels including framing to opening and
all necessary accessories

Aluminium Framed Glazed Panels

B 3855 x 3525 (Type W-39) 5 no

C 3760 x 3525 (Type W-154) 5 no

Aluminium framed glazed panel consists of two


equal and the other two equal fixed panels, each
panel made up of four unequal panels including
framing to opening and all necessary accessories

Aluminium Framed Glazed Panels

D 4500 x 5600 (Type W-36) 32 no

Aluminium framed glazed panel consists of one


fixed panels, including framing to opening, all all
necessary accessories

Aluminium Framed Glazed Panels

E 4500 x 5600 (Type W-36a) 64 no

To Collection

Bill No. 3 - Page 10


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

Collection

Bill No. 3 - Page 9

Bill No. 3 - Page 10

To Summary

Bill No. 3 - Page 11


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

BACKGROUNDS (INTERNALLY)
Render; two coat work 18 mm thick
Walls

A W07 80 m

Floor Screed; to receive floor finishes as specified

B 40mm thick 28 m

BACKGROUNDS (EXTERNALLY)

Render; two coat work 20 mm thick

Walls

C W07 17708 m

FINISHINGS (INTERNALLY)

Dividing Strips; Including stainless steel strips,


beddings, and sealants as required; As per Dwg
No. 5310A/SD9/001-005

Dividing Strips

D Generally 99 m

Quarry tiles; Including adhesives, trowelable levelling


and patching compound, edgings and fixings

Floors

E F15 28 m2

Skirting

F S11; 125 high 41 m

Ceramic tiles; Anti-microbial, including adhesives,


trowelable levelling and patching compound, edgings
and fixings

Walls

G W05 80 m2
Paint; Acrylic emulsion paint finish, including 1 no.
coat primer and 2 no. coat finish

Ceilings

H C1 17 m2

To Collection

Bill No. 3 - Page 12


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
FINISHINGS (EXTERNALLY)

Textured Acrylic Paint

Walls

A W1 16221 m2

Un-Textured Acrylic Paint

Walls

B W2 1487 m2

Stone cladding; finish as specified; complete with


all fixings, angles, abutments, closures, flashings,
sealant, membranes 30 thick UNITs; including all
associated rails, brackets, anchors as required

Walls

C W4; Limestone panel 1500x800x30mm 9424 m2

Perforated Aluminium Screen; finish as specified;


complete with all fixings, angles, abutments,
closures, flashings, sealant, membranes

Walls

D D3; 5mm Aluminium screen 2497 m2

SUSPENDED CEILINGS (INTERNALLY)

Suspended Ceiling System system; suspended on


and including metal framed suspension system;
complete with all fixings, subsidiary supports,
framing and boarding as required

Ceiling

E C7 17 m2

To Collection

Bill No. 3 - Page 13


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

Collection

Bill No. 3 - Page 12

Bill No. 3 - Page 13

To Summary

Bill No. 3 - Page 14


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION AMOUNT AED

Summary

SECTION B - SITE WORKS Bill No. 3 - Page 1

SECTION C - CONCRETE Bill No. 3 - Page 5

SECTION D - MASONRY Bill No. 3 - Page 6

SECTION E - METALWORK Bill No. 3 - Page 7

SECTION G - THERMAL AND MOISTURE Bill No. 3 - Page 8

SECTION H - DOORS AND WINDOWS Bill No. 3 - Page 11

SECTION J - FINISHES Bill No. 3 - Page 14

To General Summary

Bill No. 3 - Page 15


Bill No. 4 SEAFOOD RESTAURANT
MAIN CONTRACT
INTERCONTINENTAL RESORT HOTEL
RAK PROPERTIES

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

EARTHWORK

Earthwork including excavation in all materials,


backfilling, compaction and removal of surplus
excavated materials from site

A Generally 245 m3

FILLING

Approved filling materials as shown on Drawings and as


Specification

B Generally 571 m3

SURFACE PREPARATION

Anti-termite treatment

C Generally 815 m2

To Summary

Bill No. 4 - Page 1


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

POURED CONCRETE: SUBSTRUCTURE

Reinforced Concrete, Mix Type 1

Raft Foundation

A 300 thick 244 m3

Reinforced Concrete, Mix Type 3

B Pad footings 20 m3

Reinforced Concrete, Mix Type 4; Blended smooth


finish

Blinding

C 50 thick 815 m2

POURED CONCRETE: SUPERSTRUCTURE

Reinforced Concrete, Mix Type 2

D Slabs 325 m3

Reinforced Concrete, Mix Type 3

E Walls 84 m3

F Columns 22 m3

Light Weight Concrete, Mix Type 4

Suspended slabs, floors, landings, roofs or the like

G Ramp 106 m3

To Collection

Bill No. 4 - Page 2


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

REINFORCEMENT: SUBSTRUCTURE

High grade steel deformed bars including rolling


margin, supports, spacers; all diameters;
reinforcement in accordance with the information on
the drawings, specifications and subsequent
instructions

A Raft foundation 13360 kg

B Pad footings 580 kg

REINFORCEMENT: SUPERSTRUCTURE

High grade steel deformed bars including rolling


margin, supports, spacers; all diameters;
reinforcement in accordance with the information on
the drawings, specifications and subsequent
instructions

C Columns 5475 kg

D Walls 4890 kg

E Slabs 31782 kg

F Beams 19620 kg

SHUTTERING: SUBSTRUCTURE

Temporary shuttering for cast in situ concrete;


smooth finish

G Sides of pad footings 78 m2

H Sides of raft foundation 40 m2

SHUTTERING: SUPERSTRUCTURE

Temporary shuttering for cast in situ concrete;


smooth finish

J Sides of columns 275 m2

K Sides and soffits slabs 1630 m2

To Collection

Bill No. 4 - Page 3


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

SHUTTERING: SUPERSTRUCTURE

Temporary shuttering for cast in situ concrete;


smooth finish

A Sides and soffits of beams 720 m2

B Sides of walls 480 m2

C Sides of ramps, including slope 21 m2

To Collection

Bill No. 4 - Page 4


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

Collection

Bill No. 4 - Page 2

Bill No. 4 - Page 3

Bill No. 4 - Page 4

To Summary

Bill No. 4 - Page 5


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION D - MASONRY

WALLS AND PIERS

Block Work; bedded and jointed in cement mortar


including ties, bed, joints, head restraining systems,
vertical and base, joints, filler, fire and sound
stopping, sealant and grouting

Pre Insulated Block Work

A 250 thick; Type 1 47 m2

Dense Hollow Block Work

B 150 thick; Type 4 140 m2

Light Weight AAC Block Work

C 100 thick; Type 5 55 m2

Mid Weight AAC Block Work

D 200 thick; Type 3 47 m2

External Block Work; bedded and jointed in cement


mortar including ties, bed, joints, head restraining
systems, vertical and base, joints, filler, fire and
sound stopping, sealant and grouting

Pre Insulated Block Work

E 250 thick, overall; Type 2 197 m2

To Summary

Bill No. 4 - Page 6


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION E - METALWORK

NON - STRUCTURAL METALWORK

Aluminium Composite Panels; Including all fixings,


angles, abutments, closures, flashings, sealant,
insulation, membranes, associated secondary
structural steel support, bracing, stiffeners as
required

Walls

A W3 17 m2

Aluminium Louvre Fins 100 x 100 x 5 Super durable


coating finish ; Including all fixings, angles,
abutments, closures, flashings, sealant, insulation,
membranes, associated secondary structural steel
support, bracing, stiffeners as required

Generally

B Feature Seafood Restaurant drawing 703 75 m2

Ladders; including plates, angles, bolts, plinths etc

Generally

C Cat ladder; galvanised steel; 2.2 m approx height; 400


mm approx width; location - seafood restaurant plant
room; refer to drawing 5310/A/SD11/071 1 no

D Cat ladder; galvanised steel; 4.4 m approx height; 400


mm approx width; location - seafood restaurant ground
to plant room; refer to drawing 5310/A/SD11/071 1 no

To Summary

Bill No. 4 - Page 7


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION G - THERMAL AND MOISTURE
PROTECTION

WATERPROOFING

Waterproofing; 5 mm thick SBS waterproof


membrane including all fillers, abutments, angles,
working around obstructions and the like

Raft, Slabs and the like

A Horizontally 1403 m2

B Vertically 40 m2

COVERINGS AND LININGS

Polythene Sheet

Coverings to insulation

C Flat 1403 m2

Waterproofing; 5 mm thick SBS waterproof


membrane including all fillers, abutments, angles,
working around obstructions and the like

Raft, Walls, Slabs and the like

D Horizontally 1403 m2

Light weight screed waterproofing

Roof waterproofing; 30-110 mm thick

E Horizontally 1403 m2

Cement sand fillet

Roof waterproofing

F Horizontally 340 m2

INSULATION

Insulation; 60 thick rigid

Generally

G Flat 1403 m2

To Summary

Bill No. 4 - Page 8


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

DOORS

Steel door; Including metal frames, fixings,


finishings, sealants and leaf finish

External Doors

A D-48; 1030 x 2165 2 no

WINDOWS

Skylights: Nominal Super durable coated Aluminium


sections type D, glazed as per the specifications
covered with 5mm thick perforated Aluminium
Screen in frames as indicated on drawings super
durable bronze colour metallic finish or equal to
Engineer's approval.

As Engineer details

B 2000 x 6500 to match D3 with 5 perforated


aluminium screen in frames - Executive Lounge 2 no

C 7000 x 10500 to match D3 with 5 perforated


aluminium screen in frames 1 no

SCREENS

Aluminium framed double glazing panel consists of


one fixed panel, one singe leaf double glazing door
and three equal fixed top panels including framing to
opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

D 3250 x 5500 (Type D-40) 1 no

To Collection

Bill No. 4 - Page 9


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

SCREENS

Aluminium framed double glazing panel consists of


six panels folding doors each side and six fixed top
panels, including framing to opening, all necessary
accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

A 6800 x 5500, including Bi Fold doors (Type D-41) 2 no

Aluminium framed double glazing panel consists of


three fixed bottom panels and three fixed top panels
including framing to opening, all necessary
accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

B 3250 x 5500 including Bi Fold doors (Type D-42) 1 no

Aluminium framed double glazing panel consists of


two fixed panels on both sides, one single leaf
glazed door and one fixed top panels including
framing to opening, all necessary accessories,
finishings and ironmongeries

Aluminium Framed Glazed Panels

C 1500 x 5500 (Type D-43) 3 no

Aluminium framed double glazing panel consists of


three panels folding doors one side only and three
fixed top panels, including framing to opening, all
necessary accessories, finishes and ironmongeries

Aluminium Framed Glazed Panels

D 3025 x 5500 including Bi Fold doors (Type D-44) 2 no

E 2950 x 5500 including Bi Fold doors (Type D-45) 1 no

F 3250 x 5500 including Bi fold doors (Type D-46) 1 no

To Collection

Bill No. 4 - Page 10


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

SCREENS

Aluminium framed double glazing panel consists of


double leaves glazed door, side doors on both sides
and three fixed top panels, including framing to
opening, all necessary accessories, finishes and
ironmongeries

Aluminium Framed Glazed Panels

A 3250 x 5500 including Bi Fold doors (Type D-47) 1 no

To Collection

Bill No. 4 - Page 11


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION H - DOORS AND WINDOWS

Collection

Bill No. 4 - Page 9

Bill No. 4 - Page 10

Bill No. 4 - Page 11

To Summary

Bill No. 4 - Page 12


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

BACKGROUNDS (INTERNALLY)

Suspended Ceiling System system; suspended on


and including metal framed suspension system;
complete with all fixings, subsidiary supports,
framing and boarding as required

Ceilings

A C7 96 m2

FINISHINGS (INTERNALLY)

Dividing Strips; Including stainless steel strips,


beddings, and sealants as required; As per Dwg No.
5310A/SD9/001-005

Dividing Strips

B Generally 4 m

Carpet tiles; Including adhesives, trowelable levelling


and patching compound, edgings, gripper rods,
fixings

Floors

C F1 51 m2

Ceramic tiles; Including adhesives, trowelable


levelling and patching compound, edgings and fixings

Floors

D F5 5 m2

Walls

E W02 14 m2

Skirting

F S5; 100 high 55 m

To Collection

Bill No. 4 - Page 13


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (INTERNALLY)

Ceramic tiles; Anti-microbial, including adhesives,


trowelable levelling and patching compound, edgings
and fixings

Walls

A W05 245 m2

Terrazzo tiles; Including adhesives, trowelable


levelling and patching compound, edgings and fixings

Floors

B F11 22 m2

Quarry tiles; Including adhesives, trowelable levelling


and patching compound, edgings and fixings

Floors

C F15 48 m2

Vinyl; Including adhesives, trowelable levelling and


patching compound, edgings and fixings

Floors

D F3 30 m2

Vinyl coved; Including adhesives, trowelable levelling


and patching compound, edgings and fixings

Skirting

E S3 136 m

Acrylic; Including one coat sealer, two coats paint

Ceilings

F C1 31 m2

To Collection

Bill No. 4 - Page 14


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (INTERNALLY)

Epoxy; Including one coat sealer, two coats paint

Floors

A F4 78 m2

B F6 102 m2

Walls

C W08 125 m2

Skirting

D S7 84 m

E S8 244 m

Concrete sealer;

Floors

F F10 8 m2

Paint; Acrylic emulsion paint finish, including 1 no.


coat primer and 2 no. coat finish

Walls

G W01 136 m2

Tiles; Mineral fibre acoustic tiles, with exposed grid

Ceilings

H C6 17 m2

Tiles; Metal tiles, with hard vinyl liner

Ceilings

J C5 79 m2

To Collection

Bill No. 4 - Page 15


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (INTERNALLY)

Exposed structure

Ceilings

A C12 95 m2

FINISHINGS (EXTERNALLY)

Stone cladding; finish as specified; complete with all


fixings, angles, abutments, closures, flashings,
sealant, membranes 30 thick units; including all
associated rails, brackets, anchors as required

Walls

B Lime stone panel 1500x80x30mm 131 m2

Brushed Stainless Steel; complete with all fixings,


angles, abutments, closures, flashings, sealant,
membranes

Walls

C D14 11 m2

To Collection

Bill No. 4 - Page 16


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

Collection

Bill No. 4 - Page 13

Bill No. 4 - Page 14

Bill No. 4 - Page 15

Bill No. 4 - Page 16

To Summary

Bill No. 4 - Page 17


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

Summary

SECTION B - SITE WORKS Bill No. 4 - Page 1

SECTION C - CONCRETE Bill No. 4 - Page 5

SECTION D - MASONRY Bill No. 4 - Page 6

SECTION E - METALWORK Bill No. 4 - Page 7

SECTION G - THERMAL AND MOISTURE Bill No. 4 - Page 8

SECTION H - DOORS AND WINDOWS Bill No. 4 - Page 12

SECTION J - FINISHES Bill No. 4 - Page 17

To General Summary

Bill No. 4 - Page 18


Bill No. 5 MECHANICAL/ELECTRICAL & PLUMBING
MAIN CONTRACT
INTERCONTINENTAL RESORT HOTEL
RAK PROPERTIES

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Main Hotel
Intercontinental Resort Hotel
RAK Properties

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION

FIRE FIGHTING

Site Piping System

Supply and install all Site Fire Piping System as


shown on the drawings and/or as specified including but
not limited to all piping, fittings, angles, ells, tees,
reducers, valves, insulation supports, trenching
backfill, base, encasement, sleeves, thrust blocks
and any other item required for a complete installation
as indicated.

A 50mm FF HDPE Piping 60 m

B 80mm FF HDPE Piping 75 m

C 110mm FF HDPE Piping 60 m

D 150mm FF HDPE Piping 50 m

E 200mm FF HDPE Piping 525 m

F 280mm FF HDPE Piping 365 m

To Collection
1
Bill No. 5 - Page 1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING |(Cont'd)

Piping System Building

Supply and install all Fire Piping System as shown


on the drawings and/or as specified including but not
limited to all piping, fittings, angels, ells, tees,
reducers, valves, heads, supports, and any other items
required for a complete installation as indicated.
Contractor is responsible for assuring that their price is
for a Civil Defence acceptable system. Testing
and commissioning shall be included in all rates.

Piping

A 25mm FF Piping 8,167 m

B 32mm FF Piping 1,914 m

C 40mm FF Piping 3,139 m

D 50mm FF Piping 1,264 m

E 65mm FF Piping 920 m

F 80mm FF Piping 996 m

G 100mm FF Piping 977 m

H 150mm FF Piping 2,349 m

J 200mm FF Piping 15 m

K 75mm FF Piping 79 m

To Collection
2
Bill No. 5 - Page 2
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

Valves

A 150mm FF ZVC Valve Assembly 25 No

B Air release valve w/PG 9 No

Sprinkler Heads

C Sprinkler Head Pendent Concealed High Temp rated 12 No

D Sprinkler Head Pendent Concealed 2,636 No

E Sprinkler Head Pendent Recessed 125 No

F Sprinkler Head Upright 1,489 No

G Sprinkler Head Double Layer (Upright & Concealed) 1,071 No

H Sprinkler Head Double Layer (Upright & Recessed) 314 No

J Sprinkler Head Side Wall 53 No

K Sprinkler Head Side Wall Extended Cov. (Guest Rooms) 267 No

Devices

L 4 Way Breaching Outlet Assembly 3 No

M Fire Hydrant Assembly 6 No

To Collection
3
Bill No. 5 - Page 3
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

FIRE EXTINGUSHERS

Supply and install all Fire Extinguishers as shown on


the drawings and/or as specified including but not
limited to all extinguishers singularly or in groups, open
mounted or in enclosures of the type called for, and any
other items required for a complete installation.

Extinguishers

A Fire Extinguisher 4.5KG Dry Power / 4.5KG CO2 107 No

B Fire Extinguisher 4.5KG Dry Power 4 No

C Fire Extinguisher 25KG Dry Power Trolley Type 7 No

FIRE HOSE CABINETS

Supply and install all Fire Hose Cabinets as shown on


the drawings and/or as specified including but not
limited to all hoses, valves, extinguishers, mounted in
enclosures of the type called for, and any other items
required for a complete installation as indicated

Cabinets

D FHC Fire Hose Cabinet 13 No

E FHC-1 Fire Hose Cabinet 27 No

F FHC-2 Fire Hose Cabinet 25 No

G FHC-5 Fire Hose Cabinet 30 No

H FHC-6 Fire Hose Cabinet 5 No

To Collection
4
Bill No. 5 - Page 4
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

FIRE FIGHTING EQUIPMENT & TANKS

Supply and install all Fire Equipment and Tanks as


shown on the drawings and specified including but not
limited to pumps, piping, valves, reducers, ells, tees,
headers, gauges, meters, supports, control panels,
wiring, fuel piping, exhaust piping, mufflers, testing,
commissioning and any other items required for a
complete installation as indicated.

Pumps

A Fire Pump Set Diesel/Electric 1000 GPM 2 No

B Fire Jockey Pump 35 GPM 2 No

Tanks

C Associated piping, valves, controls, monitors, alarms 1 Item


for all RC tank

Automatic Main Sprinkler Control Valve Assembly

Supply and install the Automatic Main Sprinkler


Control Valve assembly as shown on drawings and
specified including but not limited to all piping, headers,
fitting, angles, ells, tees, reducers, gauges, meters,
control, wiring, FA and BMS interface, supports and
any other items required for a complete installation as
indicated.

Assemblies

D Main Fire Fighting Control Valve Assembly 1 No

To Collection
5
Bill No. 5 - Page 5
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

CLEAN AGENT & FOAM FIRE FIGHTING SYSTEMS

Supply and install all Clean Agent & Foam Fire Fighting
Systems as shown on the drawings and/or as specified
including but not limited to all design, engineering,
authority approvals, storage tanks, piping, supports,
valves, gauges, ells, tees, reducers, heads, controls,
pull stations, detectors, alarms, interfacing and any
other items required for a complete installation as
indicated. Testing and commissioning shall be
included in all rates.

A Volume of room requiring Clean Agent protection 2,650 m3

B Foam Supression for TX Room (Chiller yard) 136 m2

C Foam Supression for TX Room (Vehicle Court) 98 m2

D Foam Supression for TX Room (RMU area) 71 m2

E Foam Supression for Generator room 1 58 m2

F Foam Supression for Generator room 2 40 m2

To Collection
6
Bill No. 5 - Page 6
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that his lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
7
Bill No. 5 - Page 7
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

COLLECTION

Bill No. 5 - Page 1

Bill No. 5 - Page 2

Bill No. 5 - Page 3

Bill No. 5 - Page 4

Bill No. 5 - Page 5

Bill No. 5 - Page 6

Bill No. 5 - Page 7

To Summary
8
Bill No. 5 - Page 8
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION (Cont'd)

PLUMBING
DOMESTIC WATER

Site Piping System

Supply and install all Site Domestic Water Piping


System as shown on the drawings and/or as specified
including but not limited to all piping, fittings, angles,
ells, tees, reducers, valves, manholes, vaults, supports,
trenching, backfilling, base, concrete encasement,
sleeves, truss blocks and any other item as required
for a complete installation as indicated.

A 20mm HDPE Piping 55 m

B 25mm HDPE Piping 165 m

C 32mm HDPE Piping 402 m

D 40mm HDPE Piping 816 m

E 50mm HDPE Piping 228 m

F 65mm HDPE Piping 18 m

G 75mm HDPE Piping 3 m

H 80mm HDPE Piping 464 m

J 110mm HDPE Piping 372 m

K 150mm HDPE Piping 5 m

L 160mm HDPE Piping 17 m

To Collection
9
Bill No. 5 - Page 9
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
Piping System

Supply and install all Domestic Water Piping


System as shown on the drawings and/or as specified
including but not limited to all piping, fittings, angles,
ells, tees, reducers, valves, regulators, insulation,
cladding, trenching, backfill, supports and any other
items required for a complete installation as indicated.

Piping

A 15mm PPR Piping 5,224 m

B 20mm PPR Piping 11,844 m

C 25mm PPR Piping 2,851 m

D 32mm PPR Piping 3,099 m

E 40mm PPR Piping 1,967 m

F 50mm PPR Piping 3,002 m

G 65mm PPR Piping 1,407 m

H 80mm PPR Piping 870 m

J 100mm PPR Piping 859 m

K 150mm PPR Piping 106 m

Branch PEX Wall Drop

L Branch PEX Wall Drop w/insulation 1-CW 75 No

M Branch PEX Wall Drop w/insulation 2-CW 402 No

N Branch PEX Wall Drop w/insulation 1-CW & 1-HW 1,164 No

To Collection
10
Bill No. 5 - Page 10
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
DOMESTIC WATER

Devices

A Check Valve 20mm 2 No

B Check Valve 32mm 1 No

C Check Valve 40mm 4 No

D Check Valve 50mm 1 No

E Double Regulating Valve 15mm Assembly 3 No

F Double Regulating Valve 20mm Assembly 1 No

G Double Regulating Valve 65mm Assembly 1 No

H Non Return Valve 15mm 14 No

J Non Return Valve 20mm 49 No

K Non Return Valve 65mm 1 No

L Regulating valve 15mm 12 No

M Regulating valve 20mm 19 No

N Pressure Reducing Valve 65mm Assembly 1 No

P Pressure Reducing Valve 80mm Assembly 2 No

Q Pressure Reducing Valve 150mm Assembly 1 No

R Pressure Reducing Valve Assembly - Public area 37 No

S Public Area Valve Assembly set 30 No

T Guest Room Valve Assembly set 314 No

U Valve Box 6 No

V WH Water Hammer 15mm 155 No

W WH Water Hammer 20mm 744 No

X WH Water Hammer 25mm 6 No

Y WH Water Hammer 32mm 9 No

To Collection
11
Bill No. 5 - Page 11
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
DOMESTIC WATER

A Automatic Air Valve 15mm 22 No

B Automatic Air Valve 20mm 105 No

C Automatic Air Valve 25mm 39 No

D Automatic Air Valve 32mm 5 No

E Automatic Air Valve 40mm 1 No

F Automatic Air Valve 50mm 6 No

G Automatic Air Valve 150mm 2 No

H Hose Bib 15mm 3 No

J Hose Bib 20mm 49 No

K Pressure Guage 174 No

L Tempreature Guage 114 No

M Water Meter Assembly 25mm 1 No

N Water Meter Assembly 40mm 2 No

P Water Meter Assembly 150mm 1 No

Q Flow Meter Assembly 20mm 1 No

R Flow Meter Assembly 50mm 2 No

S Flow Meter Assembly 80mm 1 No

To Collection
12
Bill No. 5 - Page 12
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
DOMESTIC WATER

Equipment

A Irrigation Water booster pump Set 2D/S Assembly 1 Set


13.5 l/s 65 HD

B GR Flush. Water boost. pump Set 2D/S Assembly 1 Set


5.37 l/s 65m HD

C Makeup Water pump Set D/S Assembly 1 Set


9.2 l/s 68m HD

D Public Area. Wat. Boost. pump Set D/S Assembly 1 Set


4.63 l/s 50m HD

E Filter Feed pump Set D/S Assembly 1 Set


9.19 l/s 39m HD

F GR CW Water boost. pump Set 2D/S Assembly 1 Set


6.6 l/s 63m HD

G Kitchen P/A CW Water boost. pump Set 2D/S Assembly 1 Set


5.37 l/s 51m HD

H Vil-Chal-SFR CW boost. pump Set D/S Assembly 1 Set


3.75 l/s 42m HD

K Kitchen P/A HW booster pump Set D/S Assembly 1 Set


2.35 l/s 30m HD

L GR HW return pump Set D/S Assembly 1 Set


2.4 l/s 30m HD

M GR HW return pump Set D/S Assembly 1 Set


2.0 l/s 46m HD

N Kitchen P/A HW boost. pump Set Assembly 1 Set


5.5 l/s 51m HD

P Boiler Circulating. pump Set D/S Assembly 1 Set


11.93 l/s 20m HD

Q Hot Water Boiler Gas 850KW 2 No

R Steam Generator 6.6KW 2 No

To Collection
13
Bill No. 5 - Page 13
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
DOMESTIC WATER

Equipment (Cont'd)

A GR HW boost. pump Set 2D/S Assembly 1 Set


4.23 l/s 64m HD

B SR HW return. Pump set D/S Assembly 1 Set


0.36 l/s 3m HD

C Solar Water heating. pump Set D/S Assembly 1 Set


6.5 l/s 47m HD

D Solar Delivery Skid w/HEX Assembly 2 Set


3.25 l/s 20m HD

E Solar Heat store 5000L Assembly 6 No

F GR HW storage calorifier 500L Assembly 1 No

G Kitchen and Public area HW storage calorifier 500L Assembly 1 No

H Domestic water heat exchanger 232KW 1 No

Tanks

J assoc. piping, valves, controls, monitors, alarms 1 Item


for RC tank as required and where applicable

SOLAR PANEL WATER HEATING SYSTEM

Supply and install the Solar Panel Water Heating


System as shown on the drawings and specified
including but not limited to pumps, piping, valves,
reducers, flanges, enclosures, ells, tees, headers,
tanks, gauges, meters, supports, insulation, cladding,
control panels, wiring, BMS interface, testing,
commissioning, design, engineering and any other
assoc. items as indicated.

K SLP- Solar Panels including assoc. items and equip. 380 No

To Collection
14
Bill No. 5 - Page 14
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
SANITARY DRAINAGE

SANITARY DRAINAGE & VENT PIPING

Supply and install piping as shown on the drawings


and specified including but not limited to all fitting,
angles, ells, clean outs, reducers, trust blocks, vaults,
trenching, backfilling, fittings, supports, insulation, and
any other items required for a complete installation as
indicated.

uPVC Sanitary Pipe Site

Included in Building takeoff below

uPVC Pipe Building

A 25mm uPVC Piping 5 m

B 32mm uPVC Piping 1,637 m

C 40mm uPVC Piping 20 m

D 50mm uPVC Piping 6,836 m

E 65mm uPVC Piping 340 m

F 75mm uPVC Piping 2,205 m

G 80mm uPVC Piping 260 m

H 110mm uPVC Piping 9,230 m

J 160mm uPVC Piping 1,870 m

K 200mm uPVC Piping 980 m

L Sanitary ware Branch Drain Piping 50mm uPVC 1,239 No

M Sanitary ware Branch Drain Piping 110mm uPVC 402 No

Acoustic Insulation

N Acoustic insulation for drainage Item

To Collection
15
Bill No. 5 - Page 15
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
SANITARY DRAINAGE

Kitchen Waste Piping (HDPH)

A 32mm Kitchen waste Piping 70 m

B 50mm Kitchen waste Piping 330 m

C 65mm Kitchen waste Piping 8 m

D 75mm Kitchen waste Piping 270 m

E 80mm Kitchen waste Piping 20 m

F 110mm Kitchen waste Piping 395 m

G 160mm Kitchen waste Piping 190 m

Drains & Cleanouts

H FT/FD 1,062 No

J PRD 11 No

K FCO 148 No

L 200x150mm CD Channel Linear Drain P/meter 10 No

M 200x200mm CD Channel Linear Drain P/meter 102 No

N 200x300mm CD Channel Linear Drain P/meter 234 No

P 300x300mm CD Channel Linear Drain P/meter 44 No

Q Tundish Drain 13 No

R SRWO 5 No

S 100mm S/S Linear Drain P/meter 148 m

T PD Pond Drain 105 No

U CPFD 16 No

W BD 306 No

To Collection
16
Bill No. 5 - Page 16
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
SANITARY DRAINAGE

Devices

A 50mm Vent Cowl 1 No

B 100mm Vent Cowl 60 No

Valves

C 50mm Gate valve assebly 1 No

D 65mm Gate valve assebly 2 No

E 80mm Gate valve assembly 3 No

F 100mm Gate valve assebly 4 No

G 150mm Gate valve assebly 4 No

Manhole and Boxes

H IC Inspection Chambers 2 No

J Floor gully 5 No

K Sand Trap 2 No

L Gully Trap 51 No

M Pressure Break MH 3 No

N Foul Water MH 51 No

P Storm Water MH 18 No

Q Waste Water MH 2 No

R Petrol Interceptor 0.1 - 2.0 l/s 2 No

S Grease Interceptor 3.50 - 8.20 l/s 2 No

To Collection
17
Bill No. 5 - Page 17
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
SANITARY DRAINAGE

Sanitary Ware

Supply and install all Sanitary Ware as shown on the


drawings and specified including but not limited to all
fitting, angles, ells, valves, piping, traps and any other
items required for a complete installation as indicated.

A W/C w/\HS 399 No

B W/C w/\HS (ADA) 3 No

C Bidet w/HS 43 No

D W/B (Vanity Type) 482 No

E W/B (Pedestrial Type) 10 No

F W/B (ADA) 3 No

G Ablution Sink 6 No

H SH 355 No

J BT 319 No

K Urinal 16 No

L Jacuzzi 5 No

To Collection
18
Bill No. 5 - Page 18
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
STORM WATER DRAINAGE

STORM DRAIN PIPING SYSTEM

Supply and install piping as shown on the drawings


and specified including but not limited to all fitting,
angles, ells, clean outs, reducers, trust blocks, vaults,
trenching, backfilling, fittings, supports, insulation and
any other items required for a complete installation as
indicated.

uPVC Pipe

A 80mm uPVC Piping 40 m

B 110mm uPVC Piping 2,601 m

C 160mm uPVC Piping 490 m

E 200mm uPVC Piping 275 m

F RWO 200x200 103 No

G RWO 400x400 13 No

H RWO Dome 79 No

J Weep hole 130 No

To Collection
19
Bill No. 5 - Page 19
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
STORM WATER DRAINAGE

EQUIPMENT & TANKS

Supply and install all Storm Water Drainage Equipment


and Tanks as shown on the drawings and specified
including but not limited to pumps, piping, valves,
reducers, flanges, enclosures, ells, tees, headers,
gauges, meters, supports, control panels, wiring,
and any other items required for a complete installation.

Pumps

A Foul Water Pump 3.1 - 5.0 l/s D/S 1 No

B Foul Water Pump 5.1 - 7.0 l/s D/S 2 No

C Foul Water Pump 9.1 - 11.0 l/s D/S 2 No

F Tunnel Waste Water Pump 1.0 - 2.5 l/s 3 No

G Rain Water Pump 2.0 - 3.5 l/s 1 No

To Collection
20
Bill No. 5 - Page 20
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
LPG GAS

PIPING SYSTEM

Supply and install all LPG Gas piping as shown on the


drawings and specified including but not limited to all
fitting, angles, ells, reducers, fittings, gauges, outlets,
valves, supports, trenching, sleeves, and any other
items required for a complete installation as indicated.
Rates shall also include Leak Detectors, Detector
Monitoring Panels and all control and monitoring
cables direct buried or with containment as required.

Site

A 50mm HDPE Gas piping underground 76 m

B 32mm HDPE Gas piping underground 411 m

C 25mm HDPE Gas piping underground 53 m

D 110mm HDPE Gas piping underground 28 m

E 20mm SCH 40 Gas piping underground 3 m

F 25mm SCH 40 Gas piping underground 61 m

Buildings

G 80mm Gas piping pipe in pipe 116 m

H 65mm Gas piping pipe in pipe 73 m

J 50mm Gas piping pipe in pipe 41 m

K 40mm Gas piping pipe in pipe 178 m

L 32mm Gas piping pipe in pipe 339 m

M 25mm Gas piping pipe in pipe 29 m

N 20mm Gas piping pipe in pipe 42 m

P 15mm Gas piping pipe in pipe 39 m

To Collection
21
Bill No. 5 - Page 21
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
LPG GAS

EQUIPMENT / TANKS

Supply and install all LPG Gas Equipment, Tanks, as


Control panels, wiring, valves, regulators, meters as
shown on the drawings and specified including but not
limited to all fitting, angles, ells, reducers, fittings, gauges,
outlets, valves, meters, supports, trenching, sleeves,
and any other items required for a complete installation
required for a complete installation as indicated.
Rates shall also include final branch piping and
connection to cooking or feature equipment.

A LPG Tank 16,000 Liters w/ associated piping 2 No

B Vaporizer 30KW 1 No

C Filing Point w/ associated piping 1 No

D Meter and Controls Assembly - Boiler Room 1 No

E Meter and Controls Assembly - Banquet area regeneration kitchen 1 No

F Meter and Controls Assembly - Executive Lounge Kitchen 1 No

G Meter and Controls Assembly - Hot Kitchen 1 No

H Meter and Controls Assembly - Add support kitchen and Bulk cooking 1 No

J Meter and Controls Assembly - Staff dining support kitchen 1 No

K Meter and Controls Assembly - Servery 1 No

L Meter and Controls Assembly - Bakery and Pastry Room 1 No

M Meter and Controls Assembly - Pork kitchen 1 No

N Meter and Controls Assembly - Seafood Restaurant 1 No

P Meter and Controls Assembly - Brasserie support kitchen 1 No

To Collection
22
Bill No. 5 - Page 22
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
LPG GAS

EQUIPMENT / TANKS

A Meter and Controls Assembly - Fire Pits (2) 1 No

B Meter and Controls Assembly - Fire Pits (9) 1 No

C Main Gas Alarm and Repeater Panels 1 No

D 2nd Stag PRDP 1 No

E 3nd Stag PRDP 4 No

F 1st Stag PRDP 1 No

To Collection
23
Bill No. 5 - Page 23
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that his lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
24
Bill No. 5 - Page 24
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

COLLECTION

Bill No. 5 - Page 9

Bill No. 5 - Page 10

Bill No. 5 - Page 11

Bill No. 5 - Page 12

Bill No. 5 - Page 13

Bill No. 5 - Page 14

Bill No. 5 - Page 15

Bill No. 5 - Page 16

Bill No. 5 - Page 17

Bill No. 5 - Page 18

Bill No. 5 - Page 19

Bill No. 5 - Page 20

Bill No. 5 - Page 21

Bill No. 5 - Page 22

Bill No. 5 - Page 23

Bill No. 5 - Page 24

To Summary
25
Bill No. 5 - Page 25
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION (Cont'd)

HVAC

Site CHW Piping System

CHW Piping System Site Pre Insulated underground

Furnish and install all Site CHW Piping System as


shown on the drawings and/or as specified including but
not limited to all pre-insulated piping, fittings, angels,
ells, tees, reducers, valves, gauges, meters, supports,
trenching, base, backfilling, sleeves, truss blocks,
flanges, encasement, control cable copper and FO,
panels, manholes, chambers and any other items
required for a complete installation as indicated.

A 20mm CHW Piping Pre insulated underground 30 m

B 32mm CHW Piping Pre insulated underground 80 m

C 40mm CHW Piping Pre insulated underground 280 m

D 65mm CHW Piping Pre insulated underground 205 m

E 80mm CHW Piping Pre insulated underground 105 m

F 100mm CHW Piping Pre insulated underground 320 m

G 150mm CHW Piping Pre insulated underground 190 m

H 300mm CHW Piping Pre insulated underground 50 m

To Collection
26
Bill No. 5 - Page 26
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

CHW Piping System Building

Furnish and install all CHW Piping System as shown on


the drawings and/or as specified including but not
limited to all piping, fittings, angels, ells, tees, reducers,
valves, insulation, supports and any other items required
for a complete installation as indicated.

A 20mm CHW piping 6,850 m

B 25mm CHW piping 1,247 m

C 32mm CHW piping 2,490 m

D 40mm CHW piping 1,350 m

E 50mm CHW piping 670 m

F 65mm CHW piping 560 m

G 80mm CHW piping 200 m

H 100mm CHW piping 245 m

J 150mm CHW piping 705 m

K 200mm CHW piping 555 m

L 250mm CHW piping 25 m

M 300mm CHW piping 240 m

To Collection
27
Bill No. 5 - Page 27
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

CHW Piping Control and Connection to Equipment

Furnish and install all CHW Equipment Connection


Assembly Units as shown on the drawings and/or as
specified including but not limited to all piping, fittings,
angels, ells, tees, reducers, valves, meters,
gauges, control valves, actuators, strainer, flex piping,
insulation, supports and any other items required for a
complete installation as indicated.

A 20mm CHW piping conn to equipment 638 No

B 25mm CHW piping conn to equipment 31 No

C 32mm CHW piping conn to equipment 4 No

D 40mm CHW piping conn to equipment 2 No

E 50mm CHW piping conn to equipment 3 No

F 65mm CHW piping conn to equipment 8 No

G 80mm CHW piping conn to equipment 4 No

H 100mm CHW piping conn to equipment 4 No

To Collection
28
Bill No. 5 - Page 28
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

CHW Equipment

Furnish and install all CHW Equipment and Assembly


as shown on the drawings and/or as specified
including but not limited to all piping, controls, fittings,
angels, ells, tees, reducers, valves, meters, headers
gauges, control valves, actuators, strainer, flex piping,
insulation, cables, FO cables, containment, supports
and any other items required for a complete installation
as indicated.

A Chiller Air Cooled 1500 KW 4 No

B Chiller Air Cooled 843 KW 1 No

C Chiller Air Cooled 210 KW 1 No

D Chiller Water Pump 39.8 l/s 70m HD 5 No

E Chiller Water Pump 5.58 l/s 30m HD 2 No

F Site Meter in Vault 5 No

G Chemical dosing pump assembly Item

H Pressurization unit (3 kW) 4 No

To Collection
29
Bill No. 5 - Page 29
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

HVAC DUCTWORK

Furnish and install all HVAC Duct System as shown on


the drawings and/or as specified including but not
limited to all rectangular, round and flex ducts fittings,
angels, ells, offsets, reducers, plenums, insulation,
VCD dampers, supports and any other items required
for a complete installation. All duct shall be fire rated
where required.

Rectangular Ductwork

A Galvanized Duct 0.6mm 19,894 m2

B Galvanized Duct 0.8mm 8,381 m2

C Galvanized Duct 1.0mm 3,543 m2

D Galvanized Duct 1.2mm 3,459 m2

E Galvanized Duct 1.4mm 801 m2

F Galvanized Duct 0.6mm FR 1,729 m2

G Galvanized Duct 0.8mm FR 1,596 m2

H Galvanized Duct 1.0mm FR 48 m2

J Galvanized Duct 1.2mm FR 4 m2

K Galvanized Duct 1.4mm FR 631 m2

Insulation for Rectangular Duct

M Duct Insulation 18,441 m2

N 50mm foil faced mineral wool 378 m2

P Acoustic Insulation Item

To Collection
30
Bill No. 5 - Page 30
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

DUCT CONTROL DEVICES

Furnish and install all HVAC Duct System as shown on


the drawings and/or as specified including but not
limited to all motors volume dampers, fire dampers and
smoke dampers motorized as required, attenuators and
any other items required for a complete installation as
indicated. All duct shall be fire rated where required.

Attenuators

A 400 x 250 Attenuator 2 No

B 500 x 250 Attenuator 1 No

C 500 x 300 Attenuator 1 No

D 500 x 350 Attenuator 1 No

E 500 x400 Attenuator 1 No

F 600 x 300 Attenuator 2 No

G 700 x 600 Attenuator 4 No

H 750 x 500 Attenuator 8 No

J 750 x 550 Attenuator 2 No

K 900 x 400 Attenuator 1 No

L 1000 x 650 Attenuator 4 No

M 1050 x 350 Attenuator 4 No

N 1100 x 900 Attenuator 1 No

P 1200 x 600 Attenuator 1 No

Q 1250 x 800 Attenuator 1 No

R 1300 x 750 Attenuator 1 No

S 1550 x 500 Attenuator 1 No

T 1750 x 500 Attenuator 1 No

To Collection
31
Bill No. 5 - Page 31
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

GRILLS/DIFFUSSERS/LOUVERS

A SG 350 x 350mm 1 No

B SG 400 x 150mm 1 No

C SG 450 x 300mm 2 No

D SG 550 x 200mm 1 No

E SG 600 x 150mm 12 No

F SG 650 x 200mm 3 No

G SG 700 x 200mm 7 No

H SG 750 x 150mm 22 No

J SG 750 x 200mm 7 No

K SG 900 x 150mm 1 No

L SG 900 x 200mm 2 No

M SG 900 x 250mm 2 No

N SG 900 x 500mm 2 No

P SG 1050 x 150mm 1 No

Q SG 1200 x 200mm 2 No

R SG 1200 x 600mm 2 No

S SG 1200 x 1200mm 1 No

T SLBG 700 x 200mm 7 No

U SLBG 800 x 100mm 196 No

V SLBG 1000 x 100mm 56 No

X SLBG 1000 x 150mm 7 No

Y SLBG 1500 x 100mm 5 No

Z SLBG 1600 x 100mm 394 No

To Collection
32
Bill No. 5 - Page 32
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

GRILLS/DIFFUSSERS/LOUVERS (Cont'd)

A SLBG 1800 x 100mm 5 No

B SLBG 2000 x 100mm 58 No

C SLBG 2250 x 100mm 196 No

D SLBG 2500 x 100mm 14 No

E SLBG 3000 x 100mm 6 No

F SLBG 3500 x 100mm 5 No

Return Grill

G RG 350 x 350mm 2 No

H RG 400 x 150mm 1 No

J RG 450 x 300mm 2 No

K RG 550 x 200mm 1 No

L RG 600 x 150mm 13 No

M RG 650 x 200mm 2 No

N RG 750 x 150mm 22 No

P RG 750 x 200mm 4 No

Q RG 900 x 200mm 3 No

R RG 900 x 500mm 1 No

S RG 1050 x 150mm 1 No

T RG 1200 x 200mm 2 No

U RG 1200 x 600mm 2 No

V RG 1200 x 1200mm 1 No

W RLBG 700 x 200mm 7 No

X RLBG 600 x 100mm 4 No

Y RLBG 800 x 100mm 196 No

To Collection
33
Bill No. 5 - Page 33
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

GRILLS/DIFFUSSERS/LOUVERS (Cont'd)

Return Grill

A RLBG 2000 x 100mm 58 No

B RLBG 3000 x 100mm 6 No

C RLBG 4000 x 100mm 1 No

D 2 Slot return cove 1,092 No

Extract Grill

E EG 250 x 150mm 1 No

F EG 900 x 300mm 10 No

G EG 300 x 1000mm 159 No

H EG 1000 x 300mm 194 No

Stair Pressurization Grill

J SPG 1000 x 500mm 8 No

K SPG 1200 x 500mm 2 No

L SPG 1200 x 600mm 20 No

M SPG 1200 x 650mm 5 No

Disc valve

N DV-01 42 No

P DV-02 1 No

To Collection
34
Bill No. 5 - Page 34
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

GRILLS/DIFFUSSERS/LOUVERS (Cont'd)

Supply Diffuser

A SD4-1 66 No

B SD4-2 150 No

C SD4-3 967 No

D SD4-4 70 No

E SD4-5 6 No

F SD4-6 3 No

G SLD-1 565 No

H SLD-2 513 No

J SLD-3 523 No

K SLD-4 7 No

L SLD-6 3 No

To Collection
35
Bill No. 5 - Page 35
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

GRILLS/DIFFUSSERS/LOUVERS (Cont'd)

Return Diffuser

A RD4-1 29 No

B RD4-2 134 No

C RD4-3 950 No

D RD4-4 66 No

E RD4-5 6 No

F RD4-6 3 No

G RLD-6 3 No

H RLD-3 531 No

J RLD-2 493 No

K RLD-1 323 No

Extract Diffuser

L ED1-1 14 No

M ED2-A 1 No

N ED4-1 6 No

P ED4-2 5 No

Q ED4-3 5 No

R ELD4-4 1 No

S ELD-1 208 No

Fresh Air Diffuser

T FD4-2 1 No

To Collection
36
Bill No. 5 - Page 36
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

GRILLS/DIFFUSSERS/LOUVERS (Cont'd)

Fresh Air Supply Louver

A FASL- 0.3m2 1 No

B FASL- 0.6m2 4 No

C FASL- 1.0m2 5 No

D FASL- 1.5m2 2 No

E FASL- 2.5m2 5 No

F FASL- 3.0m2 2 No

G FASL- 3.5m2 1 No

H FASL- 4.0m2 2 No

J FASL- 5.0m2 1 No

K FASL- 6.0m2 1 No

L FASL- 7.0m2 3 No

M FASL- 8.0m2 6 No

N FASL- 9.0m2 1 No

P FASL- 11.5m2 1 No

To Collection
37
Bill No. 5 - Page 37
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

GRILLS/DIFFUSSERS/LOUVERS (Cont'd)

Exhaust Air Louver

A EAL- 0.1m2 1 No

B EAL- 0.5m2 6 No

C EAL- 0.6m2 1 No

D EAL- 0.7m2 1 No

E EAL- 1.0m2 6 No

F EAL- 1.5m2 2 No

G EAL- 2.0m2 1 No

H EAL- 2.5m2 2 No

J EAL- 3.0m2 1 No

K EAL- 8.0m2 2 No

L EAL- 1800x2000 7 No

Stairway MU & Exhaust Grill w/FIRE Damper

M 300 x 400mm 22 No

N 400 x 300mm 21 No

P 1000x1000mm 8 No

Q EXG Vertical on bulkhead 521 No

To Collection
38
Bill No. 5 - Page 38
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

GRILLS/DIFFUSSERS/LOUVERS (Cont'd)

FIRE DAMPERS

A 150 x 150mm 78 No

B 200 x 150-200mm 17 No

C 250 x 150-200mm 18 No

D 300 x 150-200mm 5 No

E 350 x 150-300mm 5 No

F 400 x 200mm 2 No

G 450 x 200-250mm 6 No

H 500 x 200-350mm 7 No

J 550 x 200-400mm 6 No

K 650 x 250mm 2 No

L 750 x 250mm 1 No

M 800 x 300mm 1 No

N 1450 x 400mm 1 No

P 1650 x 500mm 1 No

MOTORIZED DAMPERS

Q 150 x 150-200mm 299 No

R 200 x 150-200mm 267 No

S 250 x 150-250mm 249 No

T 300 x 150-300mm 21 No

To Collection
39
Bill No. 5 - Page 39
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

MOTORIZED DAMPERS

A 350 x 200-250mm 12 No

B 400 x 200-250mm 8 No

C 450 x 200-400mm 11 No

D 500 x 350-500mm 5 No

E 550 x 250-400mm 11 No

F 600 x 400-500mm 3 No

G 650 x 250-450mm 2 No

H 700 x 400-600mm 3 No

J 750 x 500-550mm 7 No

K 800 x 300-600mm 5 No

L 900 x 500mm 4 No

M 750 x 1050mm 1 No

N 1000 x 700mm 2 No

P 1050 x 350mm-600 5 No

Q 1200 x 600mm 1 No

R 1250 x 800mm 1 No

S 1300 x 750mm 1 No

U 1550 x 500mm 1 No

V 1750 x 500mm 2 No

To Collection
40
Bill No. 5 - Page 40
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

HVAC EQUIPMENT

Furnish and install all HVAC Air Equipment as shown


on the drawings and/or as specified including but not
limited to all FAHUs, AHUs, VAVs, CAVs, FCUs,
Humidifiers, EFs, SEFs, KEF, Spilt DX Units, Fans of
any type, DDC controllers, stats, control wiring, BMS
interface, power connections, refrigerant lines, mounting
supports, condensation drains and any other items
required for a complete installation as indicated. All duct
shall be fire rated where required.

AIR HANDLING UNITS

A AHU 1,501 - 2,000 l/s Sup 3 No

B AHU 3,501 - 4,000 l/s Sup 2 No

C AHU 4,001 - 4,500 l/s Sup 1 No

D AHU 4,501 - 5,000 l/s Sup 1 No

E AHU 5,001 - 5,500 l/s Sup 1 No

F AHU 5,501 - 6,000 l/s Sup 1 No

G AHU 7,001 - 7,500 l/s Sup and Ret 2 No

H FAHU 501 - 1,000 l/s Sup w/Heat Recovery 1 No

J FAHU 2,001 - 2,500 l/s Sup w/Heat Recovery 4 No

K FAHU 2,501 - 3,000 l/s Sup w/Heat Recovery 2 No

L FAHU 4,501 - 5,000 l/s Sup w/Heat Recovery 1 No

M FAHU 6,001 - 6,500 l/s Sup w/Heat Recovery 1 No

N FAHU 6,501 - 7,000 l/s Sup w/Heat Recovery 1 No

To Collection
41
Bill No. 5 - Page 41
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

HVAC EQUIPMENT (Cont'd)

AIR HANDLING UNITS (Cont'd)

A MAU 1,001 - 1,500 l/s 2 No

B MAU 1,501 - 2,000 l/s 2 No

C MAU 2,001 - 2,500 l/s 1 No

D MAU 8,001 - 8,500 l/s 1 No

E CRAC 2,501 - 3,500 l/s 2 No

F CRAC 5,501 - 6,000 l/s 2 No

G FCU 001 - 100 l/s 64 No

H FCU 101 - 200 l/s 180 No

J FCU 201 - 300 l/s 230 No

K FCU 301 - 400 l/s 85 No

L FCU 401 - 500 l/s 61 No

M FCU 501 - 600 l/s 32 No

N FCU 601 - 700 l/s 15 No

P FCU 701 - 800 l/s 10 No

To Collection
42
Bill No. 5 - Page 42
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

HVAC EQUIPMENT (Cont'd)

AIR HANDLING UNITS (Cont'd)

A FCU 801 - 900 l/s 1 No

B FCU 901 - 1000 l/s 2 No

C FCU 1001 - 1100 l/s 2 No

D FCU 2001 - 2200 l/s 1 No

E DX SPLIT UNITS 2.0 KW 4 No

F DX SPLIT UNITS 6.5 KW 2 No

G ECOL UNIT 001 - 1,000 l/s 2 No

H ECOL UNIT 2,001 -3,000 l/s 2 No

J Dehumidifier 251 - 300 l/s 2 No

K Dehumidifier 351 - 400 l/s 1 No

To Collection
43
Bill No. 5 - Page 43
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

HVAC EQUIPMENT(Cont'd)

FANS

A CPEF 7,001- 7,500 l/s 3 No

B CPEF 9,001- 9,500 l/s 6 No

C EXF 001- 100 l/s 2 No

D EXF 101- 200 l/s 3 No

E EXF 401- 500 l/s 1 No

F EXF 601- 700 l/s 1 No

G EXF 3,501- 4,000 l/s 1 No

H LEF 001- 100 l/s 1 No

J LEF 101- 200 l/s 3 No

K LEF 301- 400 l/s 1 No

L LEF 401- 500 l/s 1 No

M SMEF 401- 500 l/s 4 No

N SMEF 751- 1,000 l/s 8 No

P SMEF 1,251- 1,500 l/s 8 No

Q SMEF 1,751- 2,000 l/s 2 No

R TEF 1,501- 2,000 l/s 1 No

S TEF 4,501- 5,000 l/s 1 No

To Collection
44
Bill No. 5 - Page 44
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

HVAC EQUIPMENT (Cont'd)

FANS (Cont'd)

A LPF 2,001- 2,500 l/s 2 No

B LPF 3,501- 4,000 l/s 2 No

C LPF 4,001- 4,500 l/s 1 No

D LPF 5,501- 6,000 l/s 1 No

E SPF 7,501- 10,000 l/s 16 No

G FAF 0- 500 l/s 1 No

H FAF 1,501- 2,000 l/s 1 No

J FAF 3,500- 4,000 l/s 1 No

K FAF 4,500- 5,000 l/s 1 No

L MAF 201- 300 l/s 2 No

M MAF 501- 600 l/s 6 No

N MAF 801- 900 l/s 8 No

P MAF 1,001- 1,250 l/s 2 No

Q VAV-GF-MH-AD-01 to VAV-L02-BR-16 18 No

R CAV-GF-MH-01 to CAV-L02-BR-01 2 No

U DWEF 101- 200 l/s 2 No

V DWEF 201- 300 l/s 3 No

W DWEF 401- 500 l/s 1 No

Sensors

X CO2 Sensors 46 No

Y Space temperature sensor thermostat 142 No

To Collection
45
Bill No. 5 - Page 45
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

BUILDING MANAGEMENT SYSTEM

Furnish and install a BMS System as shown on the


drawings and/or as specified including but not limited to
all Design, engineering, computers, control panels, ELV
cabling, FO cabling, backnet cabling, connection to all
specified systems, control items and devices not
covered elsewhere in the BOQ and any other items
required for a complete installation as indicated.

A BMS System and controls 1 Item

To Collection
46
Bill No. 5 - Page 46
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that his lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
47
Bill No. 5 - Page 47
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

COLLECTION

Bill No. 5 - Page 26

Bill No. 5 - Page 27

Bill No. 5 - Page 28

Bill No. 5 - Page 29

Bill No. 5 - Page 30

Bill No. 5 - Page 31

Bill No. 5 - Page 32

Bill No. 5 - Page 33

Bill No. 5 - Page 34

Bill No. 5 - Page 35

Bill No. 5 - Page 36

Bill No. 5 - Page 37

Bill No. 5 - Page 38

Bill No. 5 - Page 39

Bill No. 5 - Page 40

Bill No. 5 - Page 41

Bill No. 5 - Page 42

Bill No. 5 - Page 43

Bill No. 5 - Page 44

Bill No. 5 - Page 45

Bill No. 5 - Page 46

Bill No. 5 - Page 47

To Summary
48
Bill No. 5 - Page 48
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATION

ELECTRICAL

MEDIM VOLTAGE SYSTEM

Supply and install all MV Equipment along with Primary


and Secondary Cables as shown on the drawings
and/or as specified including but not limited to all piping,
sleeves, fittings, ells, manholes vaults, trenching,
backfilling, base, concrete encasement, controls,
utility company monitoring, and any other items
required for a complete installation as indicated
Note - Contractor to verify this scope with FEWA and
Infrastructure Contractor as parts of this may be by
others.

A RMU Unit 3 Way 8 No

B RMU Unit Extension type 1 No

C 2000KVA Oil Type 11 Transformer 11/0.4KV 7 No

D 1000KVA Oil Type 11 Transformer 11/0.4KV 1 No

E 11KV Primary Cable 3C-240 1,076 m

F 1C-630mm2 CU XLPE/SWA/PVC 600V +E/G 2,119 m

G 1C-630mm2 CU XLPE/SWA/lsf 600V +E/G 119 m

H 1C-630mm2 CU XLPE/SWA/PVC 600V + E/G FR 270 m

To Collection
49
Bill No. 5 - Page 49
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

CABLES

Supply and install all Electrical Switchgear equipment


and items as shown on the drawings and specified
including but not limited to all support, mounting, meter,
CT's, relays, interfacing, spare breakers, BMS
interface, grounding, ground cables, ground wells, spare
spaces, and any other items as required for a complete
installation as indicated.

LV Switchgear

A 3200A 4P (LV-MDB-A1) 1 No

B 3200A 4P (LV-MDB-A2) 1 No

C 3200A 4P (LV-MDB-B1) 1 No

D 3200A 4P (LV-MDB-B2) 1 No

E 3200A 4P (LV-MDB-B3) 1 No

F 3200A 4P (LV-MDB-C1) 1 No

G 3200A 4P (LV-MDB-C2) 1 No

H 3200A 4P (LV-MDB-C3) 1 No

J 2500A 4P EMDB 1 No

K 1600A 4P EMDB 1 No

L 3200A SMDB 1 No

M 630A SMDB 2 No

N 500A SMDB 5 No

P 400A SMDB 4 No

Q 350A SMDB 1 No

R 320A SMDB 1 No

S 300A SMDB 12 No

T 250A SMDB 5 No

U 225A SMDB 3 No

W 200A SMDB 2 No

To Collection
50
Bill No. 5 - Page 50
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

ELECTRICAL SWITCHGEAR (Cont'd)

LV Switchgear (Cont'd)

A 160A SDBD 2 No

B 125A SMDB 2 No

C 100A SMDB 1 No

D 80A SMDB 3 No

E 63A SMDB 1 No

F 630A ESMDB 2 No

G 400A ESMDB 2 No

H 300A ESMDB 1 No

J 200A ESMDB 2 No

K 160A ESDBD 1 No

L 125A ESMDB 2 No

M 80A ESMDB 2 No

N 63A ESMDB 1 No

P 630A MCC 1 No

Q 250A MCC 2 No

R 80A MCC 2 No

S 63A MCC 1 No

T 225A EMCC 1 No

U 125A EMCC 1 No

V 100A EMCC 1 No

W 80A EMCC 2 No

X 40A EMCC 3 No

To Collection
51
Bill No. 5 - Page 51
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

ELECTRICAL SWITCHGEAR (Cont'd)

LV Switchgear (Cont'd)

A 160A DB PANEL 2 No

B 125A DB PANEL 2 No

C 100A DB PANEL 1 No

D 80A DB PANEL 12 No

E 63A DB PANEL 19 No

F 40A DB PANEL 123 No

G 40A DB PANEL SINGLE PHASE 279 No

H 32A DB PANEL 2 No

J 100A EDB PANEL 1 No

K 80A EDB PANEL 1 No

L 63A EDB PANEL 5 No

M 40A EDB PANEL 25 No

N 32A EDB PANEL 1 No

P 400A FP 1 No

Q 350A FP 1 No

R 300A FP 2 No

S 250A FP 2 No

T 200A FP 2 No

U 63A FP 2 No

V 40A FP 10 No

W 525 KVAR UNIT 4 No

To Collection
52
Bill No. 5 - Page 52
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

ELECTRICAL SWITCHGEAR (Cont'd)

LV Switchgear (Cont'd)

A 500 KVAR UNIT 1 No

B 450 KVAR UNIT 2 No

C 225 KVAR UNIT 1 No

D 2500A 4P ATS 1 No

E 1600A 4P ATS 1 No

F Harmonic Filters 8 No

Generator

Supply and install all Generators and associated items


as shown on the drawings and specified including but
not limited to all support, mounting, interfacing,
batteries, enclosures, grounding, cables, containment,
panels, controls, exhaust piping, fuel piping and
any other items required for a complete installation
as indicated.

G 1500 KVA GEN SET 1 No

H 1000 KVA GEN SET 1 No

UPS Units

Supply and install all UPS Units and associated items


as shown on the drawings and specified including but
not limited to all support, mounting, interfacing,
batteries, enclosures, grounding, cables, containment,
panels, controls, remote panels, and any other items
as required for a complete installation as indicated.

J UPS 4KW 29 No

K UPS 20KW 1 No

L UPS 25 KW 2 No

M UPS 45KW 2 No

To Collection
53
Bill No. 5 - Page 53
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LV CABLES Building

Supply and install all LV Cables as shown on the


drawings and specified including but not limited to all
support, containment, conduit, cable tray as required,
glands, terminations ground cables, and any other
items as required for a complete installation as
indicated. Containment must be Supplied and installed
for all cables whether shown or not. Inclusive of
termination and ground cable for each item listed
Fire rated cable must be used where required.

A 4C-240mm2 CU XLPE/SWA/PVC 600V +G/C 345 m

B 4C-185mm2 CU XLPE/SWA/PVC 600V +G/C 17 m

C 4C-150mm2 CU XLPE/SWA/PVC 600V +G/C 48 m

D 4C-120mm2 CU XLPE/SWA/PVC 600V +G/C 18 m

E 4C- 70mm2 CU XLPE/SWA/PVC 600V +G/C 15 m

F 4C- 16mm2 CU XLPE/SWA/PVC 600V +G/C 197 m

G 4C-300mm2 CU XLPE/SWA/LSF 600V +G/C 4,695 m

H 4C-240mm2 CU XLPE/SWA/LSF 600V +G/C 266 m

J 4C-185mm2 CU XLPE/SWA/LSF 600V +G/C 632 m

K 4C-150mm2 CU XLPE/SWA/LSF 600V +G/C 1,301 m

L 4C-120mm2 CU XLPE/SWA/LSF 600V +G/C 318 m

M 4C- 95mm2 CU XLPE/SWA/LSF 600V +G/C 530 m

N 4C- 70mm2 CU XLPE/SWA/LSF 600V +G/C 428 m

P 4C- 50mm2 CU XLPE/SWA/LSF 600V +G/C 596 m

Q 4C- 35mm2 CU XLPE/SWA/LSF 600V +G/C 268 m

R 4C- 25mm2 CU XLPE/SWA/LSF 600V +G/C 1,226 m

To Collection
54
Bill No. 5 - Page 54
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LV CABLES Building (Cont.d)

A 4C- 16mm2 CU XLPE/SWA/LSF 600V +G/C 1,227 m

B 4C- 10mm2 CU XLPE/SWA/LSF 600V +G/C 4,200 m

C 4C- 6mm2 CU XLPE/SWA/LSF 600V +G/C 1,457 m

D 2C- 35mm2 CU XLPE/SWA/LSF 600V +G/C 416 m

E 2C- 25mm2 CU XLPE/SWA/LSF 600V +G/C 3,328 m

E 2C- 16mm2 CU XLPE/SWA/LSF 600V +G/C 4,725 m

F 2C- 10mm2 CU XLPE/SWA/LSF 600V +G/C 7,201 m

G 2C- 4mm2 CU XLPE/SWA/LSF 600V +G/C 128 m

Fire Rated Cables

H 4C-300mm2 CU XLPE/SWA/PVC 600V +G/C FR 63 m

J 4C-185mm2 CU XLPE/SWA/PVC 600V +G/C FR 175 m

K 4C-120mm2 CU XLPE/SWA/PVC 600V +G/C FR 51 m

L 4C- 95mm2 CU XLPE/SWA/PVC 600V +G/C FR 194 m

M 4C- 70mm2 CU XLPE/SWA/PVC 600V +G/C FR 447 m

N 4C- 50mm2 CU XLPE/SWA/PVC 600V +G/C FR 9 m

P 4C- 35mm2 CU XLPE/SWA/PVC 600V +G/C FR 42 m

Q 4C- 25mm2 CU XLPE/SWA/PVC 600V +G/C FR 489 m

R 4C- 16mm2 CU XLPE/SWA/PVC 600V +G/C FR 899 m

S 4C- 10mm2 CU XLPE/SWA/PVC 600V +G/C FR 2,553 m

T 4C- 6mm2 CU XLPE/SWA/PVC 600V +G/C FR 1,267 m

U 4C- 4mm2 CU XLPE/SWA/PVC 600V +G/C FR 1,867 m

V 2C- 4mm2 CU XLPE/SWA/PVC 600V +G/C FR 177 m

To Collection
55
Bill No. 5 - Page 55
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LV CABLES Site Underground

Supply and install all LV Site Cables as shown on the


drawings and specified including but not limited to all
support, containment, conduit, sleeves as required,
glands, terminations ground cables, trenching,
backfilling, manholes, vaults, cable terminations and
other items as required for a complete installation
as indicated. Fire rated cable must be used
where required.

A 4C- 10mm2 CU XLPE/SWA/PVC 600V +G/C 67 m

B 4C- 16mm2 CU XLPE/SWA/PVC 600V +G/C 339 m

C 4C- 25mm2 CU XLPE/SWA/PVC 600V +G/C 230 m

D 4C- 35mm2 CU XLPE/SWA/PVC 600V +G/C 164 m

E 4C- 50mm2 CU XLPE/SWA/PVC 600V +G/C 184 m

F 4C-240mm2 CU XLPE/SWA/PVC 600V +G/C 462 m

G 4C- 6mm2 CU XLPE/SWA/LSF 600V +G/C 101 m

H 4C- 10mm2 CU XLPE/SWA/LSF 600V +G/C 340 m

J 4C- 16mm2 CU XLPE/SWA/LSF 600V +G/C 64 m

K 4C- 25mm2 CU XLPE/SWA/LSF 600V +G/C 137 m

L 4C- 35mm2 CU XLPE/SWA/LSF 600V +G/C 139 m

M 4C- 70mm2 CU XLPE/SWA/LSF 600V +G/C 47 m

N 4C-120mm2 CU XLPE/SWA/LSF 600V +G/C 44 m

To Collection
56
Bill No. 5 - Page 56
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LV CABLES Site Underground (Cont'd)

A 4C-240mm2 CU XLPE/SWA/LSF 600V +G/C 120 m

B 4C-300mm2 CU XLPE/SWA/LSF 600V +G/C 259 m

C 4C- 10mm2 CU XLPE/SWA/LSF 600V +G/C FR 110 m

D 4C-185mm2 CU XLPE/SWA/LSF 600V +G/C FR 260 m

E Electric Manholes 1000 x 1000 3 No

F Electric Manholes 600 x 600 25 No

To Collection
57
Bill No. 5 - Page 57
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

CABLE TRAY / TRUNKING AND CONTAIMENT

Supply and install all Tray, Trunking and Containment as


shown on the drawings and specified including but not
limited to all support, angles, ells, tees, flanges,
dropouts, grounding and any other items as required for
a complete installation as indicated.

Cable Tray

A 100mm Cable Tray 1,144 m

B 150mm Cable Tray 40 m

C 200mm Cable Tray 295 m

D 250mm Cable Tray 29 m

E 300mm Cable Tray 1,925 m

F 450mm Cable Tray 875 m

G 600mm Cable Tray 1,358 m

H 700mm Cable Tray 108 m

J 750mm Cable Tray 745 m

K 900mm Cable Tray 25 m

Trunking

L 100x 100 Trunking 3,565 m

To Collection
58
Bill No. 5 - Page 58
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

POWER OUTLETS / WIRING POINTS / ISOLATORS

Supply and install all Power Outlets, Wiring Points and


Isolators as shown on the drawings and specified
including but not limited to all support, outlets, devices,
trim, cables, containment, isolators and any other
items as required for a complete installation as
indicated.

Branch Power Outlets

A 5A 1PH 1G Socket Outlet with wiring point 22 No

C 13A 1PH 1G Socket Outlet with wiring point 3,901 No

D 13A 1PH 1G Socket Outlet WP with wiring point 454 No

E 13A 1PH 2G Socket Outlet with wiring point 1,251 No

F 13A 1PH 2G Socket Outlet WP with wiring point 10 No

G 13A 1PH 1G Switched Fuse Spur Outlet w/wiring point 1,681 No

H 15A 1PH 1G Socket Outlet with wiring point 469 No

J 32A 3PH 1G Socket Outlet w/wiring point 3 No

K FB Flr Box w/6-13A Outlet with wiring point 3 No

L FB Flr Box w/5-13A Outlet with wiring point 8 No

M FB Flr Box w/3-13A Outlet with wiring point 5 No

N FB Flr Box w/2-13A Outlet with wiring point 7 No

P FB Flr Box w/1-13A Outlet with wiring point 40 No

Q FB Flr Box w/1-Internation Sock. Out. with wiring point 7 No

R FB Flr Box w/1-Internation Sock. Out,USB with wiring point 96 No

S FB Flr Box w/2-Internation Sock. Out. with wiring point 2 No

To Collection
59
Bill No. 5 - Page 59
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

POWER OUTLETS / WIRING POINTS /


ISOLATORS(Cont'd)

Power Outlets (Cont'd.)

A HD outlet with wiring point 17 No

B 125A 3PH 1G Socket Outlet w/wiring point 1 No

C 15A SPN Commando socket 2 No

D 63A 3PH 1G Socket Outlet w/wiring point 1 No

E International twin socket outlet with wiring point 335 No

F International single socket outlet with wiring point 580 No

G International single socket outlet with wiring point W/P 2 No

H Flex outlet with wiring point W/P 45 No

J USB Socket Outlet with wiring point 620 No

K Shaver Socket Outlet with wiring point No

L 20A 1PH Misc Isolator w/wiring point 40 No

M 20A 3PH Misc Isolator w/wiring point 8 No

N 32A 3PH Misc Isolator w/wiring point 30 No

P 63A 3PH Misc Isolator w/wiring point 1 No

Q Misc Kitchen Equipment Isolator w/wiring point 103 No

To Collection
60
Bill No. 5 - Page 60
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

POWER OUTLETS / WIRING POINTS /


ISOLATORS(Cont'd)

Isolators

A 16-20A 3Ph Disconnect Switch (Isolator) 108 No

B 25-32A 3Ph Disconnect Switch (Isolator) 69 No

C 40A 3Ph Disconnect Switch (Isolator) 59 No

D 63A 3Ph Disconnect Switch (Isolator) 41 No

E 80A 3Ph Disconnect Switch (Isolator) 23 No

E 100A 3Ph Disconnect Switch (Isolator) 2 No

F 125A 3Ph Disconnect Switch (Isolator) 2 No

G 160A 3Ph Disconnect Switch (Isolator) 9 No

H 200A 3Ph Disconnect Switch (Isolator) 3 No

J 16-20A 3Ph Disconnect Switch (Isolator) WP 6 No

K 25-32A 3Ph Disconnect Switch (Isolator) WP 4 No

L 40A 3Ph Disconnect Switch (Isolator) WP 5 No

M 63A 3Ph Disconnect Switch (Isolator) WP 3 No

N 1000A 3Ph Disconnect Switch (Isolator) WP 1 No

P 1600A 3Ph Disconnect Switch (Isolator) WP 4 No

To Collection
61
Bill No. 5 - Page 61
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING

Supply and install all Lighting Fixtures, Wiring Points


and Lighting Control as shown on the drawings and
specified including but not limited to all support,
mounting hardware, outlets, boxes, back boxes,
devices, trim, cables, containment, switches, dimmers,
control panels and any other items as required for a
complete installation as indicated.

Internal Lighting Fixtures

A A1 313 No

B A1E 165 No

C A2 150 No

D A2E 96 No

E AE 127 No

F AM01 179 No

G AM02 14 No

H D1 41 No

J D2 182 No

K D2/E 52 No

L DL01 593 No

M DL02 1,458 No

N DL03 332 No

P DL04 2,189 No

Q DR01 236 No

R DR02 92 No

S DR03 15 No

T DR04 9 No

U DR05 68 No
To Collection
62
Bill No. 5 - Page 62
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Internal Lighting Fixtures (Cont'd)

A DR06 20 No

B DR07 74 No

C DR08 78 No

D DR09 19 No

E DR10 20 No

F DR11 19 No

G DR12 4 No

H DR14 15 No

J DR15 20 No

K DR16 30 No

L DR17 39 No

M DR20 147 No

N DR22 68 No

P DR23 92 No

Q DR24 9 No

R DR25 23 No

S DR26 4 No

T DR27 210 No

U DR28 55 No

V DR29 16 No

W DR30 54 No

X DR31 8 No

Y DR32 9 No

To Collection
63
Bill No. 5 - Page 63
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Internal Lighting Fixtures (Cont'd)

A DS01 10 No

B F01 276 No

C F1E 49 No

D F02 279 No

E F2-Wall 7 No

F F2E 183 No

G F2E-Wall 15 No

H F03 60 No

J F3E 19 No

K FL01 296 No

L FL02 45 No

M FL03 79 No

N FL04 26 No

P FL05 5 No

Q FL06 10 No

R FL07 4 No

S FL09 34 No

T JR01 1 No

U JR02 2 No

V JR03 8 No

W JR04 16 No

X L01 523 m

To Collection
64 Bill No. 5 - Page 64
63
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Internal Lighting Fixtures (Cont'd)

A L02 66 m

B L03 18 m

C L04 364 m

D L05 288 m

E L06 68 m

F L07 12 m

G L08 74 m

H L09 49 m

J L10 14 m

K L11 56 m

L L13 12 m

M L16 11 m

N L19 100 m

P L20 2 m

Q L21 28 m

R L22 86 m

S L23 97 m

T L24 64 m

U LL01 9,202 m

V LM01A 7 No

W LM01B 2 No

X LM02 3 No

To Collection
65 Bill No. 5 - Page 65
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Internal Lighting Fixtures (Cont'd)

A LM03 41 m

B LR02 12 No

C LR03 20 No

D LS01 30 m

E PL01 186 No

F PL02 15 No

G PL04 153 No

H PL05 8 No

J PL06 17 No

K PL07 3 No

L SD01 6 No

M SD02 4 No

N ST01 8 No

P ST02 7 No

Q T 42 No

R TL01 438 No

S TL02 185 No

T TL03 41 No

U TL04 2 No

V TL05 6 No

W TL06 2 No

X TL09 1 No

Y TM01 4 No
To Collection
66 Bill No. 5 - Page 66
1
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Internal Lighting Fixtures (Cont'd)

A UB04 3 No

B UB06 150 No

C UB01 16 No

D UB02 136 No

E VS01 16 No

F VS02 3 No

G W01 37 No

H W03 146 No

J WR01 15 No

K WR02 12 No

L WR04 4 No

M WR05 6 No

N WR06 3 No

P WR07 3 No

Q WS01 638 No

R WS02 669 No

S WS03 6 No

T WS01 17 No

U WS02 42 No

V Kitchen Hood light 26 m

W Motion sensor 891 No

To Collection
67 Bill No. 5 - Page 67
1
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Facade Lighting Fixtures

A CL101A 1,346 m

B CL102A 1,825 m

C CL103A 135 m

D CL104A 109 m

E CM101A 21 No

F CM102A 2 No

G CP01A 11 No

H GR101A 37 No

J UW04A 15 m

K WM01A 14 No

L WM101A 30 No

M WM102A 54 No

N WM102B 92 No

P WM103A 8 No

Q WM104A 32 No

R WM105A 152 No

To Collection
68 Bill No. 5 - Page 68
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Landscape Lighting Fixtures

A BL01A 8 No

B BL02A 4 No

C CM01A 62 No

D CM02A 68 m

E CM03A 23 No

F CM04A 3 No

G CM05A 4 No

H CM05B 4 No

J CP01A 19 No

K CP02A 1 No

L FM01A 98 m

M FM02A 60 m

N GM01A 300 No

P GM02A 128 No

Q GM03A 34 No

R GM04A 1 No

S GR01A 451 No

T GR02A 67 No

U GR03A 204 No

V GR04A 165 No

W GR05A 12 No

To Collection
69 Bill No. 5 - Page 69
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Landscape Lighting Fixtures (Cont'd)

A PL01A 12 No

B PL02A 6 No

C UW01A 142 No

D UW02A 74 No

E UW03A 302 No

F UW04A 310 m

G WM01A 345 No

H WM02A 6 No

J WM03A 20 No

Lighting wiring points

K Internal Light fixture wiring point 14,109 No

L Façade Light Fixture wiring point 1,139 No

M Landscape Light Fixture wiring point 2,752 No

N Motion sensor 891 No

Local Switching w/ Wiring Points

P 1G1W Switch with wiring point 21 No

Master/Central Lighting / Dimming Control

Supply and install all Master/Central Lighting/Dimming


control as shown on the drawings and specified
including but not limited to all support, outlets, boxes,
devices, cables, containment, switches, dimmers,
control panels, design, engineering and any other items
as required for a complete installation as indicated.

Q Master lighting and Dimming Control Item

To Collection
70
Bill No. 5 - Page 70
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Emergency and Exit Lighting Fixtures

Supply and install all Emergency and Exit Lighting


Fixture as shown on the drawings and specified
including but not limited to all support, outlets, boxes,
devices, cables fire rated as required, control cables,
containment, switches, control and monitoring panels,
remote distribution panels, design, engineering and any
other items as required for a complete installation as
indicated.

Fixtures

A EL1 with wiring point 110 No

B EL2 with wiring point 845 No

C EL3 with wiring point 351 No

D EL3 with wiring point 4 No

E EL4 with wiring point 229 No

F EL5 with wiring point 21 No

G EL6 with wiring point 178 No

H Evacuate Sign with wiring point 425 No

J Exit Sign with wiring point 1 No

Emergency Batter System

K Master Battery Monitoring Unit 6 No

L Master Battery Sub Panels 7 No

Cable Tray

M 100mm Cable Tray 446 m

To Collection
71
Bill No. 5 - Page 71
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTNING PROTECTION SYSTEM

Supply and install the Lightning Protection System as


shown on the drawings and specified including but not
limited to all support, ground cables containment,
trenching, backfilling, bonding, test points, copper tape,
air terminals, design, engineering and any other items
as required for a complete installation as indicated.

Lightning Protection

A Down Cable bonding to tape 179 No

B Piling Bonding 161 No

C Grounding cu tape 3,205 m

To Collection
72
Bill No. 5 - Page 72
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTICAL (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that his lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
73
Bill No. 5 - Page 73
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

COLLECTION

Bill No. 5 - Page 49

Bill No. 5 - Page 50

Bill No. 5 - Page 51

Bill No. 5 - Page 52

Bill No. 5 - Page 53

Bill No. 5 - Page 54

Bill No. 5 - Page 55

Bill No. 5 - Page 56

Bill No. 5 - Page 57

Bill No. 5 - Page 58

Bill No. 5 - Page 59

Bill No. 5 - Page 60

Bill No. 5 - Page 61

Bill No. 5 - Page 62

Bill No. 5 - Page 63

Bill No. 5 - Page 64

Bill No. 5 - Page 65

Bill No. 5 - Page 66

Bill No. 5 - Page 67

Bill No. 5 - Page 68

Bill No. 5 - Page 69

Bill No. 5 - Page 70

Bill No. 5 - Page 71

Carried Forward
74
Bill No. 5 - Page 74
1
Main Hotel
Intercontinental Resort Hotel Rev.01 - Main Hotel
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

COLLECTION (Cont'd)

Brought Forward

Bill No. 5 - Page 72

Bill No. 5 - Page 73

To Summary
75 Bill No. 5 - Page 75
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATION (Cont'd)

TELECOM SYSTEM

Site Piping System

Supply and install all Telecom Ductbank Systems as


shown on the drawings and/or as specified including but
not limited to all piping, sleeves, fittings, ells, manholes,
vaults, trenching, backfilling, base, concrete
encasement, sleeves, and any other items required for a
complete installation a indicated.

A 4W 100mm Ductbank 750 m

B 2W 100mm Ductbank 250 m

Manholes

C 600 x 600 MH 7 No

D 1120 x 635 MH 2 No

E 2000 x 2000 MH 14 No

To Collection
76
Bill No. 5 - Page 76
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

NETWORK STRUCTUAL CABLE SYSTEM

Supply and install all Tele/Data A/V Network Structural


Cabling System as shown on the drawings and
specified including but not limited to all design,
supports, cabling, cable termination, boxes, devices,
trim, containment piping, flex, tray, racks, data racks,
rack interiors, copper cables, fiber optic cables,
switches, active and passive equipment, earth
grounding bars and cable , testing and any other
any other items as required for a complete installation
as indicated.

A Main Entrance Facility Room with all associated 1 Item


cables, tray and equipment

B Telephone Equipment Room with all associated 1 Item


cables tray, and equipment

C Main Telephone Equipment Room with all associated 1 Item


cables, tray and equipment

D Main Computer Room with all associated 1 Item


cables, tray and equipment

E Main GSM Equipment Room with all associated 1 Item


cables, tray and equipment

F Remote Main Building IDF Rack/Room with all 34 Item


associated cables, tray and equipment

G Villas IDF Rack/Room with all associated cables, 32 Item


tray and equipment

H Chalets IDF Rack/Room with all associated cables, 5 Item


tray and equipment

To Collection
77
Bill No. 5 - Page 77
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

HOTEL A/V SYSTEM

Supply and install all Hotel A/V Systems as shown


on the drawings and specified including but not limited
to all design, engineering, cabling, cable termination,
boxes, devices, trim, control panels, containment,
piping, flex, tray, racks, data racks, rack interiors,
rack interiors, copper cables, fiber optic cables,
switches, storage capacity, equipment, supports,
testing and any other items as required for a complete
installation as indicated.

A Hotel BGM System with all associated cabling, 1 Item


tray and equipment

B Hotel Digital Information Display System with all 1 Item


associated cable, tray and equipment

C IPTV / HITV System with all associated cable, tray 1 Item


and equipment

D Ballroom Audio System with all associated cables, 1 Item


tray and equipment

E Ballroom Video System with all associated cables, 1 Item


tray and equipment

F Meeting Room Audio Visual Systems with all 1 Item


associated cable, tray and equipment

G Guest Room Audio Visual and GRMS System 287 Item


with all cables, tray equipment & Sensors

H Suites Audio Visual and GRMS System 27 Item


with all cables, tray equipment & Sensors

J Board Room 1 & 2 Audio Video System with all associated 1 Item
cables, tray and equipment

K BOH Meeting Room Audio Video System with all associated 1 Item
cables, tray and equipment

L BOH Training Room Audio Video System with all associated 1 Item
cables, tray and equipment

To Collection
78
Bill No. 5 - Page 78
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

TELEDATA OUTLETS

Supply and install all Tele/Data Outlets as shown on the


drawings and specified including but not limited to all
support, cabling, cable termination, boxes, devices,
trim, containment piping, flex, tray, racks, data racks,
rack interiors, testing and any other items as required
for a complete installation as indicated.

A Tele/Data point 1-Cat 6A Cable Wall 2,120 No

B Tele/Data point 2-Cat 6A Cables Wall 82 No

C Tele/Data point 4-Cat 6A Cables Wall 2 No

D Tele/Data point 1-Cat 6A to Floor Box 45 No

E Tele/Data point 2-Cat 6A to Floor Box 4 No

F Tele/Data point 3-Cat 6A to Floor Box 38 No

G Tele/Data point 4-Cat 6A to Floor Box 3 No

H Data point 1-Cat 6A Cable (Wifi) Ceiling 752 No

J Data point 1-Cat 6A Cable (Wifi) Ceiling WP 16 No

K Data point 1-Cat 6A Cable (Wifi) Wall 55 No

To Collection
79
Bill No. 5 - Page 79
1
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that his lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
80
Bill No. 5 - Page 80
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

COLLECTION

Bill No. 5 - Page 76

Bill No. 5 - Page 77

Bill No. 5 - Page 78

Bill No. 5 - Page 79

Bill No. 5 - Page 80

To Summary
81
Bill No. 5 - Page 81
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATION (Cont'd)

FIRE ALARM & SECURITY

Site Interface Between Building

Supply and install all FA Cabling and Containments


shown on the drawings and/or as specified including but
not limited to all piping, sleeves, fittings, ells, manholes,
vaults, trenching, backfilling, base, concrete
encasement, cables and any other items required for a
complete installation a indicated.

A Building interface between all building and site devices 1 Item

Master FA Control Panel / Centre and Devices

Supply and install the Master FA Control Centre as


shown on the drawings and specified including but not
limited to all master panels for FA, Voice Evacuation,
Fire phone, Aspirated Smoke Detection, Smoke
Control, BMS interface, Security Centre Interface,
cable, containment, devices and any other items
indicated or required for a complete installation.

Panels and Devices

B Main Fire Alarm / Voice Evac Panel 5 No

C Repeater Fire Alarm Panel 9 No

E Optical Smoke Detector 927 No

F Optical Smoke Detector w/Sounder 323 No

F Optical Smoke Detector w/Flasher 4 No

G Heat Detector 279 No

H Combined Detector 93 No

J Manual Call Point 196 No

K Fireman's phone 115 No

L Fire Alarm Sounder 4 No

M Fire Alarm Sounder WP 21 No

To Collection
82
Bill No. 5 - Page 82
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

A Sounder w/Strobe Flasher 16 No

B Sounder w/Strobe Flasher WP 30 No

C Sounder wall mount 5 No

D Sounder wall mount WP 31 No

E Voice Evac Speaker Wall Mount 83 No

F Voice Evac Speaker Wall Mount WP 20 No

G Voice Evac Speaker Ceilling Mount 1,006 No

H 100mm Cable Tray 424 m

To Collection
83
Bill No. 5 - Page 83
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

DOOR / GATE ACCESS CONTOL

Supply and install the Door / Gate Access Control


System as shown on the drawings and specified
including but not limited to limited to all master panels,
devices, gaters, speakers, monitoring loops, barricades,
card readers, contacts, cables, containment, speakers,
monitors, and any other items indicated or required for
a complete installation.

Access Door Control

A Gate barriers with associated equipment and cables 2 No

B Road blockers with associated equipment and cables 3 No

C Door Access with associated equipment and 155 No


cables

D Door Monitor with associated equipment and 91 No


cables

ALARM MONITORING SYSTEMS

Supply and install the Alarm Monitoring Systems


as shown on the drawings and specified including
but not limited to all panels, supports, devices, outlets,
devices, outlets cable, containment control panels,
supports, and any other items indicated or required for
a complete installation.

E Restroom Monitoring System with associated 7 No


equipment and cables

F Panic Alarm Monitoring System with associated 12 No


equipment and cables

To Collection
84
Bill No. 5 - Page 84
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

TWO WAY RADIO SYSTEM

Supply and install the Two Way Radio System


as shown on the drawings and specified
including but not limited to all main stations, antennas,
devices, outlets cable, containment, master stations,
hand sets and any other items indicated or required
for a complete system as indicated or required for
complete installation.

A Two Way Radio System 1 Item

CCTV SYSTEM

Supply and install the CCTV System as shown


on the drawings and specified including but not
limited to all master panels, monitors, storage
capacity, cameras, switches, copper cables, FO
cables, termination, containment, tray, design,
engineering, poles, devices and any other items
indicated or required for a complete installation.

B Fixed Dome Camera 326 No

C PTZ Camera WP 3 No

D Fixed Camera WP 227 No

E Auto License Plate Camera 6 No

F Lift Car Camera 10 No

G Security Center complete 1 Item

To Collection
85
Bill No. 5 - Page 85
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that his lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
86
Bill No. 5 - Page 86
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

COLLECTION

Bill No. 5 - Page 82

Bill No. 5 - Page 83

Bill No. 5 - Page 84

Bill No. 5 - Page 85

Bill No. 5 - Page 86

To Summary
87
Bill No. 5 - Page 87
Intercontinental Resort Hotel Rev.01 - Main Hotel
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MAIN HOTEL SUMMARY

SECTION Q - MECHANICAL INSTALLATION

FIRE FIGHTING - Bill No. 5 - Page 8

PLUMBING - Bill No. 5 - Page 25

HVAC - Bill No. 5 - Page 48

SECTION R - ELECTRICAL INSTALLATION

ELECTRICAL - Bill No. 5 - Page 75

TELECOM SYSTEM - Bill No. 5 - Page 81

FIRE ALARM & SECURITY - Bill No. 5 - Page 87

To MEP Summary
88
Bill No. 5 - Page 88
Villa
Intercontinental Resort Hotel
RAK Properties

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION

FIRE FIGHTING

Piping System Building

Supply and install all Fire Piping System as shown


on the drawings and/or as specified including but not
limited to all piping, fittings, angels, ells, tees,
reducers, valves, heads, supports, and any other items
required for a complete installation as indicated.
Contractor is responsible for assuring that their price is
for a Civil Defence acceptable system.

Piping

A 25mm FF Piping 544 m

B 32mm FF Piping 80 m

C 40mm FF Piping 88 m

D 50mm FF Piping 160 m

E 65mm FF Piping 120 m

Sprinkler Heads

F Sprinkler Head Pendent Concealed 192 No

G Sprinkler Head Sidewall Extended Coverage 64 No

Extinguishers

H Fire Extinguisher 4.5KG Dry Power / 4.5KG CO2 16 No

J Fire Extinguisher 4.5KG Dry Power 16 No

To Collection
89
Bill No. 5 - Page 89
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING |(Cont'd)

FIRE HOSE CABINETS

Supply and install all Fire Hose Cabinets as shown on


the drawings and/or as specified including but not
limited to all hoses, valves, extinguishers, mounted in
enclosures of the type called for, and any other items
required for a complete installation as indicated

Cabinets

A FHC-3 Fire Hose Cabinet (Outdoor Recessed) 8 No

Automatic Main Sprinkler Control Valve Assembly

Supply and install the Automatic Main Sprinkler


Control Valve assembly as shown on drawings and
specified including but not limited to all piping, headers,
fitting, angles, ells, tees, reducers, gauges, meters,
control, wiring, FA and BMS interface, supports and
any other items required for a complete installation as
indicated.

Assemblies

B Main Fire Fighting Control Valve 80mm Assembly 8 No

To Collection
90
Bill No. 5 - Page 90
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
91
Bill No. 5 - Page 91
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

COLLECTION

Bill No. 5 - Page 89

Bill No. 5 - Page 90

Bill No. 5 - Page 91

To Summary
92
Bill No. 5 - Page 92
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION (Cont'd)


PLUMBING
DOMESTIC WATER
Piping System
Supply and install all Domestic Water Piping
System as shown on the drawings and/or as specified
including but not limited to all piping, fittings, angles,
ells, tees, reducers, valves, regulators, insulation,
cladding, trenching, backfill, supports and any other
items required for a complete installation as indicated.

Piping

A 15mm PPR Piping 440 m

B 20mm PPR Piping 680 m

C 25mm PPR Piping 880 m

D 32mm PPR Piping 88 m

E 40mm PPR Piping 120 m

Branch PEX Wall Drop

F Branch PEX Wall Drop w/insulation 1-CW 32 No

G Branch PEX Wall Drop w/insulation 2-CW 16 No

H Branch PEX Wall Drop w/insulation 1-CW & 1-HW 224 No

Devices

J WH Water Hammer 15mm 64 No

K WH Water Hammer 20mm 32 No

L WH Water Hammer 25mm 32 No

M Automatic Air Valve 32mm 16 No

N Hose Bib 15mm 16 No

P Hose Bib 20mm 8 No

Equipment

Q Water Heater 30 liter 32 No

R Water Heater 100 liter 32 No

S Water Meter 40mm Assembly 8 No


To Collection
93
Bill No. 5 - Page 93
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
SANITARY DRAINAGE

SANITARY DRAINAGE & VENT PIPING

Supply and install piping as shown on the drawings


and specified including but not limited to all fitting,
angles, ells, clean outs, reducers, trust blocks, vaults,
trenching, backfilling, fittings, supports, insulation, and
any other items required for a complete installation as
indicated.

uPVC Pipe Building

A 32mm uPVC Piping 288 m

B 50mm uPVC Piping 904 m

C 80mm uPVC Piping 320 m

D 110mm uPVC Piping 1,544 m

E Sanitary ware Branch Drain Piping 50mm uPVC 192 No

F Sanitary ware Branch Drain Piping 110mm uPVC 64 No

Drains & Cleanouts

G FD 128 No

H FCO 96 No

Devices

J 75mm Vent Cowl 32 No

To Collection
94
Bill No. 5 - Page 94
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
SANITARY DRAINAGE

Sanitary Ware

Supply and install all Sanitary Ware as shown on the


drawings and specified including but not limited to all
fitting, angles, ells, valves, piping, traps and any other
items required for a complete installation as indicated.

A W/C w/\HS 64 No

B Bidet w/HS 32 No

C W/B (Vanity Type) 96 No

D SH 32 No

E BT 32 No

To Collection
95
Bill No. 5 - Page 95
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)
STORM WATER DRAINAGE

STORM DRAIN PIPING SYSTEM

Supply and install piping as shown on the drawings


and specified including but not limited to all fitting,
angles, ells, clean outs, reducers, trust blocks, vaults,
trenching, backfilling, fittings, supports, insulation and
any other items required for a complete installation as
indicated.

uPVC Pipe

A 110mm uPVC Piping 208 m

B RWO 110 32 No

C 110 Flat Grating RW Outlet 32 No

To Collection
96
Bill No. 5 - Page 96
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
97
Bill No. 5 - Page 97
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

COLLECTION

Bill No. 5 - Page 93

Bill No. 5 - Page 94

Bill No. 5 - Page 95

Bill No. 5 - Page 96

Bill No. 5 - Page 97

To Summary
98
Bill No. 5 - Page 98
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION (Cont'd)

HVAC

CHW Piping System Building

Furnish and install all CHW Piping System as shown on


the drawings and/or as specified including but not
limited to all piping, fittings, angels, ells, tees, reducers,
valves, insulation, supports and any other items required
for a complete installation as indicated.

A 20mm CHW piping 440 m

B 25mm CHW piping 90 m

C 32mm CHW piping 200 m

D 40mm CHW piping 190 m

CHW Piping Control and Connection to Equipment

Furnish and install all CHW Equipment Connection


Assembly Units as shown on the drawings and/or as
specified including but not limited to all piping, fittings,
angels, ells, tees, reducers, valves, meters,
gauges, control valves, actuators, strainer, flex piping,
insulation, supports and any other items required for a
complete installation as indicated.

E 20mm CHW piping conn to equipment 64 No

F 25mm CHW piping conn to equipment 32 No

To Collection
99
Bill No. 5 - Page 99
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)
HVAC DUCTWORK

Furnish and install all HVAC Duct System as shown on


the drawings and/or as specified including but not
limited to all rectangular, round and flex ducts fittings,
angels, ells, offsets, reducers, plenums, insulation,
VCD dampers, supports and any other items required
for a complete installation. All duct shall be fire rated
where required.

Rectangular Ductwork

A Galvanized Duct 0.6mm 1,316 m2

B Galvanized Duct 0.8mm 208 m2

Insulation for Rectangular Duct

C Duct Insulation 440 m2

GRILLS/DIFFUSSERS/LOUVERS

Return Grill

D RG 1000 x 300mm 32 No

E RG 900 x 200mm 64 No

F RG 600 x 300mm 32 No

Supply Grill

G SG 1500 x 300mm 32 No

H SG 900 x 200mm 64 No

J SG 600 x 200mm 32 No

Extract Diffuser

K ED4-1 32 No

L ED2-A 32 No

Supply Diffuser

M SD4-1 32 No

To Collection
100
Bill No. 5 - Page 100
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

GRILLS/DIFFUSSERS/LOUVERS (Cont'd)

Extract Air Louver

A EAL 1.0m2 16 No

B EASL 0.1m2 16 No

Motorized Dampers

C 150x150 MD 32 No

D 200x150 MD 48 No

HVAC EQUIPMENT

Furnish and install all HVAC Air Equipment as shown


on the drawings and/or as specified including but not
limited to all FAHUs, AHUs, VAVs, CAVs, FCUs,
Humidifiers, EFs, SEFs, KEF, Spilt DX Units, Fans of
any type, DDC controllers, stats, control wiring, BMS
interface, power connections, refrigerant lines, mounting
supports, condensation drains and any other items
required for a complete installation as indicated. All duct
shall be fire rated where required.

FCU UNITS

E FCU 0 - 100 l/s 2 No

F FCU 101 - 200 l/s 16 No

G FCU 201 - 300 l/s 48 No

H FCU 401 - 500 l/s 16 No

J FCU 501 - 600 l/s 16 No

FANS

K EXF 001- 75 l/s 64 No

L FAF 001- 100 l/s 64 No

M KEF 001- 100 l/s 32 No

Sensor

N Smoke sensor 16 No
To Collection
101
Bill No. 5 - Page 101
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

BUILDING MANAGEMENT SYSTEM

Furnish and install a BMS System as shown on the


drawings and/or as specified including but not limited to
all Design, engineering, computers, control panels, ELV
cabling, FO cabling, backnet cabling, connection to all
specified systems, control items and devices not
covered elsewhere in the BOQ and any other items
required for a complete installation as indicated.

A BMS System and controls 1 Item

To Collection
102
Bill No. 5 - Page 102
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
103
Bill No. 5 - Page 103
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

COLLECTION

Bill No. 5 - Page 99

Bill No. 5 - Page 100

Bill No. 5 - Page 101

Bill No. 5 - Page 102

Bill No. 5 - Page 103

To Summary
104
Bill No. 5 - Page 104
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATION

ELECTRICAL

LV SWITCHGREAR

A In Base Contract

LV CABLES Building

B In Base Contract

POWER OUTLETS / WIRING POINTS / ISOLATORS

Supply and install all Power Outlets, Wiring Points and


Isolators as shown on the drawings and specified
including but not limited to all support, outlets, devices,
trim, cables, containment, isolators and any other
items as required for a complete installation as
indicated.

Branch Power Outlets

C 13A 1PH 1G Socket Outlet with wiring point 320 No

D 13A 1PH 1G Switched Fuse Spur Outlet w/wiring point 96 No

E 13A 1PH 1G Switched Socket Outlet with wiring point W/P 32 No

F 13A 1PH 2G Socket Outlet with wiring point 160 No

G International single socket outlet with wiring point 64 No

H Flex outlet W/P 64 No

J Flex outlet for WH 32 No

K USB Socket Outlet with wiring point 128 No

To Collection
105
Bill No. 5 - Page 105
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING

Supply and install all Lighting Fixtures, Wiring Points


and Lighting Control as shown on the drawings and
specified including but not limited to all support,
mounting hardware, outlets, boxes, back boxes,
devices, trim, cables, containment, switches, dimmers,
control panels and any other items as required for a
complete installation as indicated.

Internal Lighting Fixtures

A DL02 128 No

B F01 16 No

C FL03 16 No

D FL05 16 No

E FL06 16 No

F FL07 16 No

G LL01 301 m

H PL02 16 No

J PL04 16 No

K PL06 16 No

L TL03 32 No

M WS01 32 No

N WS03 32 No

P Motion sensor 16 No

Façade Lighting Fixtures

Q CL101A 97 m

R CL103A 93 m

S GR103A 144 No

To Collection
106
Bill No. 5 - Page 106
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Lighting Wiring Points

A Internal Light Fixture wiring point 412 No

B Façade Light Fixture wiring point 182 No

C Motion Sensor 16 No

ELECTRICAL (Cont'd)

Emergency and Exit Lighting Fixtures

Supply and install all Emergency and Exit Lighting


Fixture as shown on the drawings and specified
including but not limited to all support, outlets, boxes,
devices, cables fire rated as required, control cables,
containment, switches, control and monitoring panels,
remote distribution panels, design, engineering and any
other items as required for a complete installation as
indicated.

Fixtures

D EL3C with wiring point 32 No

LIGHTNING PROTECTION SYSTEM

Supply and install the Lightning Protection System as


shown on the drawings and specified including but not
limited to all support, ground cables containment,
trenching, backfilling, bonding, test points, copper tape,
air terminals, design, engineering and any other items
as required for a complete installation as indicated.

Lightning Protection

E Down Cable bonding to tape 64 No

F Piling Bonding 64 No

G Grounding cu tape 820 m

To Collection
107 Bill No. 5 - Page 107
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTICAL (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
108
Bill No. 5 - Page 108
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

COLLECTION

Bill No. 5 - Page 105

Bill No. 5 - Page 106

Bill No. 5 - Page 107

Bill No. 5 - Page 108

To Summary
109
Bill No. 5 - Page 109
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATION (Cont'd)

TELECOM SYSTEM

NETWORK STRUCTUAL CABLE SYSTEM

Supply and install all Tele/Data A/V Network Structural


Cabling System as shown on the drawings and
specified including but not limited to all design,
supports, cabling, cable termination, boxes, devices,
trim, containment piping, flex, tray, racks, data racks,
rack interiors, copper cables, fiber optic cables,
switches, active and passive equipment, earth
grounding bars and cable , testing and any other
any other items as required for a complete installation
as indicated.

A VILLA IDF Rack/Room (Covered in Base Contract)

TELEDATA OUTLETS

Supply and install all Tele/Data Outlets as shown on the


drawings and specified including but not limited to all
support, cabling, cable termination, boxes, devices,
trim, containment piping, flex, tray, racks, data racks,
rack interiors, testing and any other items as required
for a complete installation as indicated.

B Tele/Data point 1-Cat 6A Cable Wall 256 No

C Data point 1-Cat 6A Cable (Wifi) Ceiling 64 No

D Suites Audio Visual and GRMS System 32 No


with all cables equipment & Sensors

To Collection
110
Bill No. 5 - Page 110
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
111
Bill No. 5 - Page 111
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

COLLECTION

Bill No. 5 - Page 110

Bill No. 5 - Page 111

To Summary
112
Bill No. 5 - Page 112
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATION (Cont'd)

FIRE ALARM & SECURITY

Remote FA Control Panel / Centre and Devices

Supply and install the Master FA Control Centre as


shown on the drawings and specified including but not
limited to all master panels for FA, Voice Evacuation,
Fire phone, Aspirated Smoke Detection, Smoke
Control, BMS interface, Security Centre Interface,
cable, containment, devices and any other items
indicated or required for a complete installation.

Panels and Devices

A Optical Smoke Detector 48 No

B Optical Smoke Detector w/Sounder 32 No

C Heat Detector 32 No

D Manual Call Point 24 No

E Fire Alarm Sounder 8 No

F Fire Alarm Sounder WP 16 No

G Fire Alarm Remote Panel 8 No

To Collection
113
Bill No. 5 - Page 113
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
114
Bill No. 5 - Page 114
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

COLLECTION

Bill No. 5 - Page 113

Bill No. 5 - Page 114

To Summary
115
Bill No. 5 - Page 115
Intercontinental Resort Hotel Rev.01 - Villa
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

VILLA SUMMARY

SECTION Q - MECHANICAL INSTALLATION

FIRE FIGHTING - Bill No. 5 - Page 92

PLUMBING - Bill No. 5 - Page 98

HVAC - Bill No. 5 - Page 104

SECTION R - ELECTRICAL INSTALLATION

ELECTRICAL - Bill No. 5 - Page 109

TELECOM SYSTEM - Bill No. 5 - Page 112

FIRE ALARM & SECURITY - Bill No. 5 - Page 115

To MEP Summary
116
Bill No. 5 - Page 116
Chalet
Intercontinental Resort Hotel
RAK Properties

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - MECHANICAL INSTALLATION

FIRE FIGHTING

Piping System Building

Supply and install all Fire Piping System as shown


on the drawings and/or as specified including but not
limited to all piping, fittings, angels, ells, tees,
reducers, valves, heads, supports, and any other items
required for a complete installation as indicated.
Contractor is responsible for assuring that their price is
for a Civil Defence acceptable system.

Piping

A 25mm FF Piping 160 m

B 40mm FF Piping 20 m

C 50mm FF Piping 15 m

D 65mm FF Piping 55 m

Sprinkler Heads

E Sprinkler Head Pendent Concealed 40 No

F Sprinkler Head Double Layer (Upright & Concealed) 20 No

Extinguishers

G Fire Extinguisher 4.5KG Dry Power / 4.5KG CO2 10 No

FIRE HOSE CABINETS

Supply and install all Fire Hose Cabinets as shown on


the drawings and/or as specified including but not
limited to all hoses, valves, extinguishers, mounted in
enclosures of the type called for, and any other items
required for a complete installation as indicated

Cabinets

H FHC-3 Fire Hose Cabinet (Outdoor Recessed) 5 No

To Collection
117
Bill No. 5 - Page 117
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

Automatic Main Sprinkler Control Valve Assembly

Supply and install the Automatic Main Sprinkler


Control Valve assembly as shown on drawings and
specified including but not limited to all piping, headers,
fitting, angles, ells, tees, reducers, gauges, meters,
control, wiring, FA and BMS interface, supports and
any other items required for a complete installation as
indicated.

Assemblies

A Main Fire Fighting Control Valve 65mm Assembly 5 No

To Collection
118
Bill No. 5 - Page 118
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
119
Bill No. 5 - Page 119
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

COLLECTION

Bill No. 5 - Page 117

Bill No. 5 - Page 118

Bill No. 5 - Page 119

To Summary
120
Bill No. 5 - Page 120
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION (Cont'd)

PLUMBING

DOMESTIC WATER

Piping System

Supply and install all Domestic Water Piping


System as shown on the drawings and/or as specified
including but not limited to all piping, fittings, angles,
ells, tees, reducers, valves, regulators, insulation,
cladding, trenching, backfill, supports and any other
items required for a complete installation as indicated.

Piping

A 15mm PPR Piping 145 m

B 20mm PPR Piping 335 m

C 32mm PPR Piping 45 m

D 40mm PPR Piping 20 m

Branch PEX Wall Drop

E Branch PEX Wall Drop w/insulation 1-CW 10 No

F Branch PEX Wall Drop w/insulation 2-CW 10 No

G Branch PEX Wall Drop w/insulation 1-CW & 1-HW 45 No

Devices

H WH Water Hammer 15mm 20 No

J WH Water Hammer 20mm 5 No

K Automatic Air Valve 40mm 5 No

L Hose Bib 32mm 5 No

Equipment

M Water Heater 100 liter 5 No

N Water Heater 50 liter 5 No

P Water Meter 40mm Assembly 5 No

To Collection
121
Bill No. 5 - Page 121
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

SANITARY DRAINAGE

SANITARY DRAINAGE & VENT PIPING

Supply and install piping as shown on the drawings


and specified including but not limited to all fitting,
angles, ells, clean outs, reducers, trust blocks, vaults,
trenching, backfilling, fittings, supports, insulation, and
any other items required for a complete installation as
indicated.

uPVC Pipe Building

A 32mm uPVC Piping 30 m

B 50mm uPVC Piping 220 m

C 75mm uPVC Piping 115 m

D 110mm uPVC Piping 65 m

E Sanitary ware Branch Drain Piping 50mm uPVC 45 No

F Sanitary ware Branch Drain Piping 110mm uPVC 10 No

Drains & Cleanouts

G FD 25 No

H FCO 10 No

Devices

J 50mm Vent Cowl 10 No

Sanitary Ware

Supply and install all Sanitary Ware as shown on the


drawings and specified including but not limited to all
fitting, angles, ells, valves, piping, traps and any other
items required for a complete installation as indicated.

K W/C w/\HS 10 No

L Bidet w/HS 10 No

M W/B (Vanity Type) 20 No

N SH 10 No

P BT 5 No

To Collection
122
Bill No. 5 - Page 122
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

SANITARY DRAINAGE

STORM DRAIN PIPING SYSTEM

Supply and install piping as shown on the drawings


and specified including but not limited to all fitting,
angles, ells, clean outs, reducers, trust blocks, vaults,
trenching, backfilling, fittings, supports, insulation and
any other items required for a complete installation as
indicated.

uPVC Pipe

A 110mm uPVC Piping 60 m

B RWO 200 x 200 10 No

To Collection
123
Bill No. 5 - Page 123
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
124
Bill No. 5 - Page 124
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

COLLECTION

Bill No. 5 - Page 121

Bill No. 5 - Page 122

Bill No. 5 - Page 123

Bill No. 5 - Page 124

To Summary
125
Bill No. 5 - Page 125
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION (Cont'd)

HVAC

CHW Piping System Building

Furnish and install all CHW Piping System as shown on


the drawings and/or as specified including but not
limited to all piping, fittings, angels, ells, tees, reducers,
valves, insulation, supports and any other items required
for a complete installation as indicated.

A 20mm CHW piping 12 m

B 25mm CHW piping 160 m

C 32mm CHW piping 60 m

CHW Piping Control and Connection to Equipment

Furnish and install all CHW Equipment Connection


Assembly Units as shown on the drawings and/or as
specified including but not limited to all piping, fittings,
angels, ells, tees, reducers, valves, meters,
gauges, control valves, actuators, strainer, flex piping,
insulation, supports and any other items required for a
complete installation as indicated.

D 20mm CHW piping conn to equipment 5 m

E 25mm CHW piping conn to equipment 10 m

To Collection
126
Bill No. 5 - Page 126
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

HVAC DUCTWORK

Furnish and install all HVAC Duct System as shown on


the drawings and/or as specified including but not
limited to all rectangular, round and flex ducts fittings,
angels, ells, offsets, reducers, plenums, insulation,
VCD dampers, supports and any other items required
for a complete installation. All duct shall be fire rated
where required.

Rectangular Ductwork

A Galvanized Duct 0.6mm 116 m2

B Galvanized Duct 0.8mm 50 m2

Insulation for Rectangular Duct

C Duct Insulation 80 m2

GRILLS/DIFFUSSERS/LOUVERS

Return Grill

D RG 1350 x 250mm 5 No

E RG 1600 x 200mm 10 No

Supply Grill

F SG 1350 x 250mm 5 No

G SG 1600 x 200mm 10 No

Extract Grill

H EXG No

Supply Diffuser
Kitchen P/A CW Water boost. pump Set 2D/S Assembly
J SD4-4 5 No

Return Diffuser

K RD4-4 5 No

Extract Air Louver

L EAL 5 No

M FASL 10 No

Motorized Dampers

N MD 150 x 100mm 15 No

O MD 200 x 100mm 5 No

To Collection
127
Bill No. 5 - Page 127
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

HVAC EQUIPMENT

Furnish and install all HVAC Air Equipment as shown


on the drawings and/or as specified including but not
limited to all FAHUs, AHUs, VAVs, CAVs, FCUs,
Humidifiers, EFs, SEFs, KEF, Spilt DX Units, Fans of
any type, DDC controllers, stats, control wiring, BMS
interface, power connections, refrigerant lines, mounting
supports, condensation drains and any other items
required for a complete installation as indicated. All duct
shall be fire rated where required.

FCU UNITS

A FCU 0 - 100 l/s 2 No

B FCU 201 - 300 l/s 5 No

C FCU 401 - 500 l/s 5 No

D FCU 501 - 600 l/s 5 No

FANS

E EXF 0- 50 l/s 1 No

F FAF 0- 100 l/s 1 No

Sensors

Thermostat with humidity control 10 No

BUILDING MANAGEMENT SYSTEM

Furnish and install a BMS System as shown on the


drawings and/or as specified including but not limited to
all Design, engineering, computers, control panels, ELV
cabling, FO cabling, backnet cabling, connection to all
specified systems, control items and devices not
covered elsewhere in the BOQ and any other items
required for a complete installation as indicated.

G BMS System and controls 5 Item

To Collection
128
Bill No. 5 - Page 128
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
129
Bill No. 5 - Page 129
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

COLLECTION

Bill No. 5 - Page 126

Bill No. 5 - Page 127

Bill No. 5 - Page 128

Bill No. 5 - Page 129

To Summary
130
Bill No. 5 - Page 130
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATION

ELECTRICAL

LV SWITCHGREAR

A In Base Contract

LV CABLES Building

B In Base Contract

POWER OUTLETS / WIRING POINTS / ISOLATORS

Supply and install all Power Outlets, Wiring Points and


Isolators as shown on the drawings and specified
including but not limited to all support, outlets, devices,
trim, cables, containment, isolators and any other
items as required for a complete installation as
indicated.

Branch Power Outlets

C 13A 1PH 1G Socket Outlet with wiring point 70 No

D 13A 1PH 2G Socket Outlet with wiring point 25 No

E 13A 1PH 1G Switched Fuse Spur Outlet w/wiring point 30 No

F International twin socket outlet with wiring point 15 No

G International single socket outlet with wiring point 5 No

H Flex outlet with wiring point 5 No

J Flex outlet for WH with wiring point 10 No

K USB Socket Outlet with wiring point 15 No

To Collection
131
Bill No. 5 - Page 131
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING
Supply and install all Lighting Fixtures, Wiring Points
and Lighting Control as shown on the drawings and
specified including but not limited to all support,
mounting hardware, outlets, boxes, back boxes,
devices, trim, cables, containment, switches, dimmers,
control panels and any other items as required for a
complete installation as indicated.

Internal Lighting Fixtures

A DL02 50 No

B DL03 5 No

C F2 5 No

D FL03 5 No

E FL06 5 No

F FL08 5 No

G LL01 61 m

H PL04 5 No

J PL05 5 No

K PL06 5 No

L PL07 5 No

M TL06 5 No

N WS01 10 No

P WS02 10 No

Q WS03 5 No

Facade Lighting Fixtures

R CL102A 810 m

S CM102A 10 No

T GR102A 60 No

U UW101A 20 No

V WM104A 5 No

Lighting Wiring Points

W Internal Light Fixture wiring point 137 No

X Facade Light Fixture wiring point 257 No

To Collection
132
Bill No. 5 - Page 132
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

Emergency and Exit Lighting Fixtures

Supply and install all Emergency and Exit Lighting


Fixture as shown on the drawings and specified
including but not limited to all support, outlets, boxes,
devices, cables fire rated as required, control cables,
containment, switches, control and monitoring panels,
remote distribution panels, design, engineering and any
other items as required for a complete installation as
indicated.

Fixtures

A EL3C with wiring point 5 No

LIGHTNING PROTECTION SYSTEM

Supply and install the Lightning Protection System as


shown on the drawings and specified including but not
limited to all support, ground cables containment,
trenching, backfilling, bonding, test points, copper tape,
air terminals, design, engineering and any other items
as required for a complete installation as indicated.

Lightning Protection

B Down Cable bonding to tape 20 No

C Piling Bonding 20 No

D Grounding cu tape 275 m

To Collection
133
Bill No. 5 - Page 133
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
134
Bill No. 5 - Page 134
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

COLLECTION

Bill No. 5 - Page 132

Bill No. 5 - Page 133

Bill No. 5 - Page 134

To Summary
135
Bill No. 5 - Page 135
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATION (Cont'd)

TELECOM SYSTEM

NETWORK STRUCTUAL CABLE SYSTEM

Supply and install all Tele/Data A/V Network Structural


Cabling System as shown on the drawings and
specified including but not limited to all design,
supports, cabling, cable termination, boxes, devices,
trim, containment piping, flex, tray, racks, data racks,
rack interiors, copper cables, fiber optic cables,
switches, active and passive equipment, earth
grounding bars and cable , testing and any other
any other items as required for a complete installation
as indicated.

A Chalet IDF Rack/Room (Covered in Base Contract)

TELEDATA OUTLETS

Supply and install all Tele/Data Outlets as shown on the


drawings and specified including but not limited to all
support, cabling, cable termination, boxes, devices,
trim, containment piping, flex, tray, racks, data racks,
rack interiors, testing and any other items as required
for a complete installation as indicated.

B Tele/Data point 1-Cat 6A Cable Wall 45 No

C Data point 1-Cat 6A Cable (Wifi) Ceiling 10 No

D Suites Audio Visual and GRMS System 5 No


with all cables equipment & Sensors

To Collection
136
Bill No. 5 - Page 136
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
137
Bill No. 5 - Page 137
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

COLLECTION

Bill No. 5 - Page 136

Bill No. 5 - Page 137

To Summary
138
Bill No. 5 - Page 138
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATION (Cont'd)

FIRE ALARM & SECURITY

Remote FA Control Panel / Centre and Devices

Supply and install the Master FA Control Centre as


shown on the drawings and specified including but not
limited to all master panels for FA, Voice Evacuation,
Fire phone, Aspirated Smoke Detection, Smoke
Control, BMS interface, Security Centre Interface,
cable, containment, devices and any other items
indicated or required for a complete installation.

Panels and Devices

A Optical Smoke Detector 5 No

B Optical Smoke Detector w/Sounder 5 No

C Manual Call Point 5 No

D Fire Alarm Sounder WP 3 No

E Fire Alarm Remote Main Panel 5 No

To Collection
139
Bill No. 5 - Page 139
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
140
Bill No. 5 - Page 140
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

COLLECTION

Bill No. 5 - Page 139

Bill No. 5 - Page 140

To Summary
141
Bill No. 5 - Page 141
Intercontinental Resort Hotel Rev.01 - Chalet
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

CHALET SUMMARY

SECTION Q - MECHANICAL INSTALLATIONS

FIRE FIGHTING SYSTEM - Bill No. 5 - Page 120

PLUMBING - Bill No. 5 - Page 125

HVAC - Bill No. 5 - Page 130

SECTION R - ELECTRICAL INSTALLATIONS

ELECTRICAL - Bill No. 5 - Page 135

TELECOM SYSTEM - Bill No. 5 - Page 138

ELECTRONIC SAFETY & SECURITY - Bill No. 5 - Page 141

To MEP Summary
142
Bill No. 5 - Page 142
Seafood Restaurant
Intercontinental Resort Hotel
RAK Properties

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION

FIRE FIGHTING

Piping System Building

Supply and install all Fire Piping System as shown


on the drawings and/or as specified including but not
limited to all piping, fittings, angels, ells, tees,
reducers, valves, heads, supports, and any other items
required for a complete installation as indicated.
Contractor is responsible for assuring that their price is
for a Civil Defence acceptable system.

Piping

A 25mm FF Piping 80 m

B 32mm FF Piping 20 m

C 40mm FF Piping 35 m

D 50mm FF Piping 40 m

E 65mm FF Piping 30 m

F 80mm FF Piping 5 m

G 100mm FF Piping 10 m

Sprinkler Heads

H Sprinkler Head Pendent Recessed 70 No

Extinguishers

J Fire Extinguisher 4.5KG Dry Power / 4.5KG CO2 2 No

To Collection
143
Bill No. 5 - Page 143
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING |(Cont'd)

FIRE HOSE CABINETS

Supply and install all Fire Hose Cabinets as shown on


the drawings and/or as specified including but not
limited to all hoses, valves, extinguishers, mounted in
enclosures of the type called for, and any other items
required for a complete installation as indicated

Cabinets

A FHC Fire Hose Cabinet 1 No

Automatic Main Sprinkler Control Valve Assembly

Supply and install the Automatic Main Sprinkler


Control Valve assembly as shown on drawings and
specified including but not limited to all piping, headers,
fitting, angles, ells, tees, reducers, gauges, meters,
control, wiring, FA and BMS interface, supports and
any other items required for a complete installation as
indicated.

Assemblies

B Main Fire Fighting Control Valve 100mm Assembly 1 No

To Collection
144
Bill No. 5 - Page 144
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
145
Bill No. 5 - Page 145
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE FIGHTING SYSTEM (Cont'd)

COLLECTION

Bill No. 5 - Page 143

Bill No. 5 - Page 144

Bill No. 5 - Page 145

To Summary
146
Bill No. 5 - Page 146
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION (Cont'd)

PLUMBING

DOMESTIC WATER

Piping System

Supply and install all Domestic Water Piping


System as shown on the drawings and/or as specified
including but not limited to all piping, fittings, angles,
ells, tees, reducers, valves, regulators, insulation,
cladding, trenching, backfill, supports and any other
items required for a complete installation as indicated.

Piping

A 15mm PPR Piping 78 m

B 20mm PPR Piping 228 m

C 25mm PPR Piping 9 m

D 32mm PPR Piping 3 m

E 40mm PPR Piping 34 m

Branch PEX Wall Drop

F Branch PEX Wall Drop w/insulation 1-CW 2 No

G Branch PEX Wall Drop w/insulation 2-CW 5 No

H Branch PEX Wall Drop w/insulation 1-CW & 1-HW 6 No

Devices

J WH Water Hammer 15mm 3 No

K WH Water Hammer 20mm 6 No

L Hose Bib 20mm 5 No

Valves

M Double Regulating Valve 15mm 5 No

N Non Return Valve 15mm 8 No

P Non Return Valve 20mm 9 No

Equipment

Q Water \heater Elec 750 Lit 1 No

To Collection
147
Bill No. 5 - Page 147
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

SANITARY DRAINAGE

SANITARY DRAINAGE & VENT PIPING

Supply and install piping as shown on the drawings


and specified including but not limited to all fitting,
angles, ells, clean outs, reducers, trust blocks, vaults,
trenching, backfilling, fittings, supports, insulation, and
any other items required for a complete installation as
indicated.

uPVC Pipe Building

A 50mm uPVC Piping 90 m

B 75mm uPVC Piping 10 m

C 110mm uPVC Piping 20 m

D Sanitary ware Branch Drain Piping 50mm uPVC 8 No

E Sanitary ware Branch Drain Piping 110mm uPVC 5 No

Kitchen Piping (HDPH)

F 25mm HDPH Piping 18 m

G 50mm HDPH Piping 110 m

H 75mm HDPH Piping 25 m

J 110mm HDPH Piping 115 m

K 160mm HDPH Piping 50 m

To Collection
148
Bill No. 5 - Page 148
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

SANITARY DRAINAGE

Drains & Cleanouts

A FD 24 No

B FCO 8 No

Devices

C 75mm Vent Cowl 2 No

Manhole and Boxes

D Covered in Main Building

To Collection
149
Bill No. 5 - Page 149
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

SANITARY DRAINAGE

Sanitary Ware

Supply and install all Sanitary Ware as shown on the


drawings and specified including but not limited to all
fitting, angles, ells, valves, piping, traps and any other
items required for a complete installation as indicated.

A W/C w/\HS 5 No

B W/B (Pedestrial Type) 6 No

C Urinal 2 No

To Collection
150
Bill No. 5 - Page 150
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

STORM WATER DRAINAGE

STORM DRAIN PIPING SYSTEM

Supply and install piping as shown on the drawings


and specified including but not limited to all fitting,
angles, ells, clean outs, reducers, trust blocks, vaults,
trenching, backfilling, fittings, supports, insulation and
any other items required for a complete installation as
indicated.

uPVC Pipe

A 110mm uPVC Piping 52 m

B 160mm uPVC Piping 6 m

C RWO 110 6 No

D RWO 200 6 No

To Collection
151
Bill No. 5 - Page 151
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

LPG GAS

PIPING SYSTEM

Supply and install all LPG Gas piping as shown on the


drawings and specified including but not limited to all
fitting, angles, ells, reducers, fittings, gauges, outlets,
valves, supports, trenching, sleeves, and any other
items required for a complete installation as indicated.
Rates shall also include Leak Detectors, Detector
Monitoring Panels and all control and monitoring
cables direct buried or with containment as required.

Buildings

A 25mm Gas piping pipe in pipe 27 m

To Collection
152
Bill No. 5 - Page 152
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PLUMBING (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
153
Bill No. 5 - Page 153
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
UNIT RATE TOTAL PRICE
ITEM ITEM DESCRIPTION QUANTITY UNIT
AED AED

PLUMBING (Cont'd)

COLLECTION

Bill No. 5 - Page 147

Bill No. 5 - Page 148

Bill No. 5 - Page 149

Bill No. 5 - Page 150

Bill No. 5 - Page 151

Bill No. 5 - Page 152

Bill No. 5 - Page 153

To Summary
154
Bill No. 5 - Page 154
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION Q - MECHANICAL INSTALLATION (Cont'd)

HVAC

CHW Piping System Building

Furnish and install all CHW Piping System as shown on


the drawings and/or as specified including but not
limited to all piping, fittings, angels, ells, tees, reducers,
valves, insulation, supports and any other items required
for a complete installation as indicated.

A 20mm CHW piping 44 m

B 25mm CHW piping 1 m

C 32mm CHW piping 25 m

C 80mm CHW piping 20 m

D 80mm CHW Meter / Chamber Assembly 1 No

CHW Piping Control and Connection to Equipment

Furnish and install all CHW Equipment Connection


Assembly Units as shown on the drawings and/or as
specified including but not limited to all piping, fittings,
angels, ells, tees, reducers, valves, meters,
gauges, control valves, actuators, strainer, flex piping,
insulation, supports and any other items required for a
complete installation as indicated.

E 20mm CHW piping conn. to equipment 5 No

F 25mm CHW piping conn. to equipment 1 No

To Collection
155
Bill No. 5 - Page 155
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

HVAC DUCTWORK

Furnish and install all HVAC Duct System as shown on


the drawings and/or as specified including but not
limited to all rectangular, round and flex ducts fittings,
angels, ells, offsets, reducers, plenums, insulation,
VCD dampers, supports and any other items required
for a complete installation. All duct shall be fire rated
where required.

Rectangular Ductwork

A Galvanized Duct 0.6mm 133 m2

B Galvanized Duct 0.8mm 71 m2

C Galvanized Duct 1.0mm 28 m2

Insulation for Rectangular Duct

D Duct Insulation 125 m2

DUCT CONTROL DEVICES

Furnish and install all HVAC Duct System as shown on


the drawings and/or as specified including but not
limited to all motors volume dampers, fire dampers and
smoke dampers motorized as required, attenuators and
any other items required for a complete installation as
indicated. All duct shall be fire rated where required.

Attenuators

E 700x 600 Attenuator 2 No

F 1250x 700 Attenuator 2 No

Motorized Dampers

G MD 350 x 200mm 1 No

H MD 400 x 150mm 2 No

Fire Dampers

J FD 150 x 150mm-200mm 5 No

K FD 200 x 150mm 2 No

L FD 200 x 200mm 1 No

M FD 250 x 200mm 1 No

N FD 350 x 200mm-250mm 4 No

P FD 450 x 300mm 1 No

Q FD 1200 x 700mm 1 No

R FD 1250 x 700mm 3 No
To Collection
156
Bill No. 5 - Page 156
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

GRILLS/DIFFUSSERS/LOUVERS

Return Grill

A RG 600 x 150mm 1 No

B RG 400 x 150mm 1 No

Supply Grill

C SG 600 x 150mm 1 No

D SG 400 x 150mm 1 No

E SLBG 1000 x 100mm 22 No

Extract Grill

F EXG 300 x 50mm 6 No

Return Diffuser

G RLD-3 53 No

H RD4-2 1 No

Supply Diffuser

J SLD-3 39 No

K SD4-4 11 No

Extract Diffuser

L ED1-1 2 No

Fresh Air Supply Louver

M FASL 2.0m2 1 No

N FASL 7.0m2 1 No

Extract Louver

P EAL 1.5m2 1 No

To Collection
157
Bill No. 5 - Page 157
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

HVAC EQUIPMENT

Furnish and install all HVAC Air Equipment as shown


on the drawings and/or as specified including but not
limited to all FAHUs, AHUs, VAVs, CAVs, FCUs,
Humidifiers, EFs, SEFs, KEF, Spilt DX Units, Fans of
any type, DDC controllers, stats, control wiring, BMS
interface, power connections, refrigerant lines, mounting
supports, condensation drains and any other items
required for a complete installation as indicated. All duct
shall be fire rated where required.

AIR HANDLING UNITS

A AHU 5001 - 6000 l/s 1 No

B MAU 1001 - 1200 l/s 1 No

C EU 1400 - 2000 l/s 1 No

FCU UNITS

D FCU 101 - 200 l/s 1 No

E FCU 201 - 300 l/s 4 No

F FCU 401 - 500 l/s 1 No

FANS

G EXF 201- 300 l/s 1 No

H EXF 501- 600 l/s 1 No

To Collection
158
Bill No. 5 - Page 158
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

BUILDING MANAGEMENT SYSTEM

Furnish and install a BMS System as shown on the


drawings and/or as specified including but not limited to
all Design, engineering, computers, control panels, ELV
cabling, FO cabling, backnet cabling, connection to all
specified systems, control items and devices not
covered elsewhere in the BOQ and any other items
required for a complete installation as indicated.

A BMS System and controls 1 Item

To Collection
159
Bill No. 5 - Page 159
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
160
Bill No. 5 - Page 160
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

HVAC (Cont'd)

COLLECTION

Bill No. 5 - Page 155

Bill No. 5 - Page 156

Bill No. 5 - Page 157

Bill No. 5 - Page 158

Bill No. 5 - Page 159

Bill No. 5 - Page 160

To Summary
161
Bill No. 5 - Page 161
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATIONS

LV SWITCHGREAR

In Base Contract

LV CABLES Building

In Base Contract

CABLE TRAY / TRUNKING AND CONTAIMENT

Supply and install all Tray, Trunking and Containment as


shown on the drawings and specified including but not
limited to all support, angles, ells, tees, flanges,
dropouts, grounding and any other items as required for
a complete installation as indicated.

Cable Tray

A 150mm Cable Tray 26 m

POWER OUTLETS / WIRING POINTS / ISOLATORS

Supply and install all Power Outlets, Wiring Points and


Isolators as shown on the drawings and specified
including but not limited to all support, outlets, devices,
trim, cables, containment, isolators and any other
items as required for a complete installation as
indicated.

Branch Power Outlets

B 13A 1PH 1G Socket Outlet with wiring point 25 No

C 13A 1PH 2G Socket Outlet with wiring point 12 No

D 13A 1PH 1G Switched Fuse Spur Outlet w/wiring point 12 No

E 15A 1PH 1G Socket Outlet with wiring point 8 No

F 20A 3PH Isolator with wiring point 1 No

G 20A 1PH Isolator with wiring point 1 No

H Misc Kitchen Equip. Isolator with wiring point 12 No

J 32A 3PH Isolator with wiring point WP 7 No

K 80A 3PH Isolator with wiring point 1 No

L International twin socket outlet with wiring point 8 No

M FB Flr Box w/1-Internation Sock. Out.,USB with wiring point 12 No

N Flex outlet with wiring point 9 No

P HD outlet with wiring point 5 No

Q USB Socket Outlet with wiring point 8 No

To Collection
162 Bill No. 5 - Page 162
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING

Supply and install all Lighting Fixtures, Wiring Points


and Lighting Control as shown on the drawings and
specified including but not limited to all support,
mounting hardware, outlets, boxes, back boxes,
devices, trim, cables, containment, switches, dimmers,
control panels and any other items as required for a
complete installation as indicated.

Internal Lighting Fixtures

A A1 9 No

B A1E 7 No

C A2 7 No

D A2E 6 No

E D 3 No

F D2 2 No

G DR08 10 No

H DR13 20 No

J DR22 10 No

K DR23 12 No

L F2 8 No

M F2E 6 No

N L01 109 m

P L19 3 m

Q PL03 13 No

R PL04 123 No

S PL05 5 No

T Motion sensor 10 No

Facade Lighting Fixtures

U CM04A 2 No

V CP01A 4 No

W CR101A 10 No

X FM01A 7 m

Y WM104A 1 No

To Collection
163 Bill No. 5 - Page 163
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTING (Cont'd)

Lighting Wiring Points

A Internal Lighting wiring point 273 No

B Façade Lighting wiring point 18 No

C Motion Sensor 10 No

Emergency and Exit Lighting Fixtures

Supply and install all Emergency and Exit Lighting


Fixture as shown on the drawings and specified
including but not limited to all support, outlets, boxes,
devices, cables fire rated as required, control cables,
containment, switches, control and monitoring panels,
remote distribution panels, design, engineering and any
other items as required for a complete installation as
indicated.

Fixtures

D EL2 with wiring point 22 No

E EL3 with wiring point 1 No

F EL4 with wiring point 6 No

G EL6 with wiring point 2 No

H Evacuation Sign with wiring point 6 No

To Collection
164 Bill No. 5 - Page 164
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

LIGHTNING PROTECTION SYSTEM

Supply and install the Lightning Protection System as


shown on the drawings and specified including but not
limited to all support, ground cables containment,
trenching, backfilling, bonding, test points, copper tape,
air terminals, design, engineering and any other items
as required for a complete installation as indicated.

Lightning Protection

A Down Cable bonding to tape 8 No

B Piling Bonding 8 No

C Grounding cu tape 202 m

To Collection
165 Bill No. 5 - Page 165
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTICAL (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
166 Bill No. 5 - Page 166
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ELECTRICAL (Cont'd)

COLLECTION

Bill No. 5 - Page 162

Bill No. 5 - Page 163

Bill No. 5 - Page 164

Bill No. 5 - Page 165

Bill No. 5 - Page 166

To Summary
167 Bill No. 5 - Page 167
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATIONS (Cont'd)

TELECOM SYSTEM

NETWORK STRUCTUAL CABLE SYSTEM

Supply and install all Tele/Data A/V Network Structural


Cabling System as shown on the drawings and
specified including but not limited to all design,
supports, cabling, cable termination, boxes, devices,
trim, containment piping, flex, tray, racks, data racks,
rack interiors, copper cables, fiber optic cables,
switches, active and passive equipment, earth
grounding bars and cable , testing and any other
any other items as required for a complete installation
as indicated.

A SFR IDF Rack/Room (Covered in Base Building)

TELEDATA OUTLETS

Supply and install all Tele/Data Outlets as shown on the


drawings and specified including but not limited to all
support, cabling, cable termination, boxes, devices,
trim, containment piping, flex, tray, racks, data racks,
rack interiors, testing and any other items as required
for a complete installation as indicated.

B Tele/Data point 1-Cat 6A Cable Wall 12 No

C Data point 1-Cat 6A Cable (Wifi) Ceiling 5 No

D Data point 1-Cat 6A Cable (Wifi) Ceiling 1 No

To Collection
168
Bill No. 5 - Page 168
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
169
Bill No. 5 - Page 169
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

TELECOM SYSTEM (Cont'd)

COLLECTION

Bill No. 5 - Page 168

Bill No. 5 - Page 169

To Collection
170
Bill No. 5 - Page 170
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SECTION R - ELECTRICAL INSTALLATIONS (Cont'd)

FIRE ALARM & SECURITY

Remote FA Control Panel / Centre and Devices

Supply and install the Master FA Control Centre as


shown on the drawings and specified including but not
limited to all master panels for FA, Voice Evacuation,
Fire phone, Aspirated Smoke Detection, Smoke
Control, BMS interface, Security Centre Interface,
cable, containment, devices and any other items
indicated or required for a complete installation.

Panels and Devices

A Remote Fire Alarm Panel 1 No

B Optical Smoke Detector 15 No

C Heat Detector 4 No

D Combined Detector 2 No

E Manual Call Point 3 No

F Fire Alarm Sounder WP 2 No

To Collection
171
Bill No. 5 - Page 171
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

Additional Items

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that the lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Collection
172
Bill No. 5 - Page 172
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

FIRE ALARM & SECURITY (Cont'd)

COLLECTION

Bill No. 5 - Page 171

Bill No. 5 - Page 172

To Summary
173
Bill No. 5 - Page 173
Intercontinental Resort Hotel Rev.01 - Seafood Restaurant
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

SEAFOOD RESTAURANT SUMMARY

SECTION Q - MECHANICAL INSTALLATIONS

FIRE FIGHTING SYSTEM - Bill No. 5 - Page 146

PLUMBING - Bill No. 5 - Page 154

HVAC - Bill No. 5 - Page 161

SECTION R - ELECTRICAL INSTALLATIONS

ELECTRICAL - Bill No. 5 - Page 167

TELECOM SYSTEM - Bill No. 5 - Page 170

ELECTRONIC SAFETY & SECURITY - Bill No. 5 - Page 173

To MEP Summary
174
Bill No. 5 - Page 174
MEP Summary
Intercontinental Resort Hotel
RAK PROPERTIES
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

MEP SUMMARY

MAIN HOTEL - Bill No. 5 - Page 88

VILLA - Bill No. 5 - Page 116

CHALET - Bill No. 5 - Page 142

SEAFOOD RESTAURANT - Bill No. 5 - Page 174

To General Collection
175
Bill No. 5 - Page 175
Bill No. 6 LANDSCAPING
MAIN CONTRACT
INTERCONTINENTAL RESORT HOTEL
RAK PROPERTIES

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

FILLING

Filling with imported material as approved by


Engineer

Fill to make up levels from the formation level

A Generally 26238 m3

200 thick compacted sub base material

B Paved Areas 2844 m3

150 depth crushed sandstone sub base material

C Paved Areas 92 m3

200 thick drainage layer consisting clean gravel with


no fines

D Tree Pits 163 m3

300 layer of free draining clean gravel

E Tree Pits 182 m3

75 thick bark mulch

F Tree Pits 1354 m2

G Shrub Areas 27325 m2

Planting Mediums

H Tree Pits 2500 m3

Cultivated sub bases

J Shrub Areas 16395 m3

K Turfed Areas 96 m3

Sand (Sand Pit)

L Playground 13 m3

To Collection

Bill No. 6 - Page 1


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

PAVING AND SURFACING

Granite Kerbs; 200 x 200 x 150, including all


necessary bedding, haunchings, blinding, bases and
compacted sub grades

Tennis Court

A Generally 106 m

Light grey coloured concrete with a rock salt finish;


400 x 400 x 40 light grey granite border to paving
with bush hammered finish, including reinforced
concrete bases, haunchings, sub bases to support
edge as required

Pool Deck Paving

B Generally 2443 m2

Travertine Paving; 40 thick light grey laid in triple


stacked 45 degrees herringbone pattern; single
running course 40 thick light grey travertine and
20-40 light grey river washed pebble banding set in
20 thick mortar; Including all bases, haunchings, sub
bases to support edge as required

Feature Paving Type 1

C Generally 287 m2

Travertine Paving; Laid in concentric linear formation


pattern; 40 thick 100 x 100 light grey granite paving
boarder with bush hammered finish and 500 x 200 x
40 light grey granite pavers with textured finish;
Including all bases, haunchings, sub bases to
support edge as required

Feature paving type 2

D Generally 140 m2

To Collection

Bill No. 6 - Page 2


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

PAVING AND SURFACING

Light Grey Concrete with rock salt finish; Pebble


banding at edge of paving and across path at 8000
centres by river washed light grey pebbles with
diameter 20-40mm and reinforced concrete base to
support pebble; Including all haunchings, sub bases
to support edge as required

Buggy Path Paving

A Generally 2306 m2

Grey Concrete; 100 thick with lightly textured


finished; 40 thick 100 x 100 light grey granite paving
with bush hammered finish; 500 x 200 x 40 light grey
granite pavers with flame textured finish and
reinforced concrete haunchings at the edges;
Including all haunchings, sub bases to support edge
as required; As per Dwg No. 179-DD-203 Detail 3

Colonnade paving

B Generally 1420 m2

Grey coloured lightly textured concrete; 500 x 200 x


40 light grey granite pavers with bush hammered at
edges and reinforced concrete base at edges; As
per Dwg No. 179-DD-203 Detail 5

Entrance footpath paving

C Generally 1205 m2

Grey Concrete; 150 thick with rock salt finish; 200 x


500 x 60 mid grey granite border to paving; 100 x
100 x 60 mid grey granite in set paving with flame
textured finish; 200 x 600 x 260 light grey granite
kerb with flamed finish with 10 chamfer and
reinforced concrete haunchings at edge; As per Dwg
No. 179-DD-201 Detail 4

Porte Cochere paving

D Generally 3977 m2

To Collection

Bill No. 6 - Page 3


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

PAVING AND SURFACING

Rubber Paving; In colour as specified and approved


by the Engineer, including, sub bases, granular
bases as required

Rubber Paving

A Generally 558 m2

Stone Paving; 200-700 x 200-700 x 80 random sized


light grey stone paving with natural finish in 30-50
gap between stepping stones

Stepping Stones (Paving)

B Generally 94 m2

Granite Paving; 200 x 400 x 40 light grey paving with


flame textured finish paved in herringbone pattern at
45 degrees and 200 x 500 x 40 granite border with
bush hammered finish

Courtyard Paving

C Generally 1332 m2

Travertine Paving; 50 thick light grey paving laid in


concentric linear formation pattern; 100 x 100 x 40
light grey granite paving with bush hammered; 100
thick light grey concrete with fine textured finish; 500
x 200 x 40 light grey granite pavers with flame
textured finish as per Dwg No. 179-DD-202 Detail 1

Entry Feature Paving

D Generally 373 m2

To Collection

Bill No. 6 - Page 4


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

PAVING AND SURFACING

Timber Deck; 200 x 25 hardwood timber decking


having smooth sawn finish and attached to 75 x 50
timber bearers with countersunk stainless steel
screw with 200 x 500 x 40 light grey granite paving
border, bush hammered

Timber Decking

A Generally 1178 m2

Acrylic Co-Polymer; Dark green colour finish with


pigment silica sand and water including 3 no coats
with 2 no coats line paint

Tennis Court Paving

B Generally 614 m2

Asphalt Base; Hot mix install 30 depth wearing


course over 40 coat at 0.75 -1.0 ltr per square meter

Tennis Court Paving

C Generally 614 m2

Stone Coping; Laid on mortar bedding and securely


fixed to wall, as required

Pool Deck Paving

D Generally 590 no

LANDSCAPING

Shrubs and Ground Covers;

Shrubs

E Agapanthus africanus 1896 m2

F Bougainvillea glabra 174 m2

G Canna indica (yellow flower) 39 m2

To Collection

Bill No. 6 - Page 5


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

LANDSCAPING

Shrubs and Ground Covers;

Shrubs

A Canna indica purpurea 438 m2

B Carissa graniflora 237 m2

C Crinum asiaticum 602 m2

D Duranta repenas 36 m2

E Eranthemum pulchellum 723 m2

F Gardenia augusta 89 m2

G Gardenia jasminoides 997 m2

H Hamelia patens 961 m2

J Hedychium spicatum 969 m2

K Heliconia acuminata 111 m2

L Hibiscus rosa sinensis (Chinese Hibiscus) 243 m2

M Hymenocallis littoralis 333 m2

N Jasminum officinale (common jasmine) 113 m2

P Murraya paniculata 126 m2

Q Nerium oleander 1130 m2

R Phormium cookianum 759 m2

S Phormium tenax 1746 m2

T Philodendron selloum 1395 m2

U Russelia Equisetiformis 522 m2

To Collection

Bill No. 6 - Page 6


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

LANDSCAPING

Shrubs and Ground Covers;

Shrubs

A Schefflera arboricola (umbrella plant) 1233 m2

B Strelitzia reginae 1198 m2

C Tradescantia spathacea 3395 m2

Coastal Ground Covers

D Carpobrotus edulis (hottentot fig) 1486 m2

E Clerodendron inerme 1650 m2

F Ipomoea pes caprae 946 m2

G Secuvium portulacastrum 1189 m2

H Vitex rotundifolia 1027 m2

Feature Mix

J Hedychium spicatum/Hibiscus rosa


sinensis (Chinese hibiscus)/Phormium tenax 391 m2

Hot Mix 1

K Heliconia acuminata/Lantana camera Sspanish


flag)/Schefflera arboricola (umbrella plant) 697 m2

Hot Mix 2

L Hedychium spicatum/Phormium
tenax/Strelitzia reginae 474 m2

Turfing;

M Generally 637 m2

To Collection

Bill No. 6 - Page 7


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION B - SITE WORKS

LANDSCAPING

Trees; Root Ball wrapped in Hessian cloth; 60mm


dia plastic drainage pipe wrapped around root ball
and timber triangle to anchor root ball

B Acacia auriculiformis; 2.5 m height 27 no

A Acacia cyanophylla; 2.5 m height 31 no

B Bauhinia variegata; 3-3.5 m height 39 no

C Callistemon citrinus; 2.5 m height 44 no

D Calophyllum inophyllum; 3-3.5 m height 26 no

F Cassia fistula; 3-3.5 m height 10 no

E Cassia nodosa; 3-3.5 m height 6 no

F Cassia surattensis; 3-3.5 m height 23 no

G Cupaniopsis anacardioides; 2-2.5 m height 77 no

G Delonix regia; 4-4.5 m height 16 no

H Ficus elastica; 3-3.5 m height 25 no

K Ficus nitida; 4 m height 9 no

J Lagerstroemia indica; 2.5-3 m height 23 no

K Livistona chinensis; 3.5 m height 45 no

L Millettia corymbosa; 5 m height 12 no

A Millingtonia hortensis; 2-2.5 m height 8 no

M Phoenix canariensis; 6 m height 55 no

D Phoenix dactylifera; 6 m height 128 no

N Roystonea regia; 4 m height 39 no

K Washingtonia robusta; 3.5 m height 81 no

M Wodyetia bifurcata; 4.5 m height 26 no

To Collection

Bill No. 6 - Page 8


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

POURED CONCRETE

Reinforced Concrete, Mix Type 1

Paving Bases

A 100 thick 331 m3

Slabs

150 thick

B Adult Pool 52 m3

C Central Pool 225 m3

D Club Pool 51 m3

E Kids Pool 37 m3

F Chalet Pool 5 m3

G Arrival Court Feature 67 m3

H Ornamental Lake Feature 196 m3

J Ornamental Stream Feature 51 m3

K Water Feature 1 23 m3

L Water Feature 2 13 m3

M Courtyard Water Feature 1 m3

N Porte Cochere Type 1 9 m3

P Porte Cochere Type 2 32 m3

Q Sunken Lawn Water Feature 16 m3

250 thick

R Water Channel 43 m3

To Collection

Bill No. 6 - Page 9


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

POURED CONCRETE

Reinforced Concrete, Mix Type 1

Slabs

400 thick

A Light Well Feature 16 m3

Walls

B Water Feature 1 2 m3

C Sunken Lawn Water Feature 5 m3

D Adult Pool 40 m3

E Central Pool 70 m3

F Club Pool 74 m3

G Kids Pool 15 m3

H Chalet Pool 44 m3

J Arrival Court Feature 25 m3

K Ornamental Lake Feature 61 m3

L Ornamental Stream Feature 21 m3

M Water Feature 2 2 m3

N Courtyard Water Feature 2 m3

P Water Channel 17 m3

Q Light Well Feature 5 m3

R Stone-clad retaining / planter wall 1390 m3

S Stone-clad free standing wall 37 m3

T Rendered concrete retaining wall 412 m3

U Rendered concrete free standing wall 28 m3

V Cascade stone-clad feature wall 16 m3

W Stone-clad wall 78 m3

To Collection

Bill No. 6 - Page 10


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

POURED CONCRETE

Reinforced Concrete, Mix Type 1

Columns

A Shade Structures 15 m3

B Porte Cochere 20 m3

C Colonnade Type 1 1 m3

Beams

D Colonnade Type 1 2 m3

Staircases and Landings

E Adult Pool 4 m3

F Central Pool 3 m3

G Club Pool 1 m3

H Kids Pool 1 m3

J Chalet Pool 6 m3

Mass Concrete, as specified

150 x 200 x 1500 sized concrete blocks to base of


tree pit and tied with cables to secure root ball

K Podium Deck Tree Pit 33 m3

L Pool Deck Tree Pit 27 m3

M Seating 15 m3

N Sunken Seating 89 m3

To Collection

Bill No. 6 - Page 11


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

REINFORCEMENT

High grade steel deformed bars including rolling


margin, supports, spacers; all diameters;
reinforcement in accordance with the information on
the drawings, specifications and subsequent
instructions

Columns

A Shade Structures 2430 kg

B Porte Cochere 3438 kg

C Colonnade 108 kg

Walls

D Adult Pool 6880 kg

E Central Pool 12040 kg

F Club Pool 12728 kg

G Kids Pool 2580 kg

H Chalet Pool 7568 kg

J Arrival Court Feature 4300 kg

K Water Channel 2924 kg

L Ornamental Lake Feature 10492 kg

M Ornamental Stream Feature 3612 kg

N Water Feature 1 344 kg

P Water Feature 2 344 kg

Q Courtyard Water Feature 346 kg

R Light Well Feature 860 kg

S Sunken Lawn Water Feature 172 kg

T Stone-clad retaining / planter wall 132085 kg

U Stone-clad free standing wall 3505 kg

V Rendered concrete retaining wall 39130 kg

W Rendered concrete free standing wall 2672 kg

X Cascade stone-clad feature wall 1476 kg

Y Stone-clad wall 7446 kg

To Collection

Bill No. 6 - Page 12


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

REINFORCEMENT

High grade steel deformed bars including rolling


margin, supports, spacers; all diameters;
reinforcement in accordance with the information on
the drawings, specifications and subsequent
instructions

Slabs

A Adult Pool 6032 kg

B Central Pool 26100 kg

C Club Pool 5916 kg

D Kids Pool 4292 kg

E Chalet Pool 580 kg

F Arrival Court Feature 2900 kg

G Water Channel 4988 kg

H Ornamental Lake Feature 22736 kg

J Ornamental Stream Feature 5916 kg

K Water Feature 1 2668 kg

L Water Feature 2 1508 kg

M Courtyard Water Feature 116 kg

N Light Well Feature 1856 kg

P Porte Cochere 4852 kg

Q Sunken Lawn Water Feature 1856 kg

Beams

R Colonnade 309 kg

To Collection

Bill No. 6 - Page 13


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

REINFORCEMENT

High grade steel deformed bars including rolling


margin, supports, spacers; all diameters;
reinforcement in accordance with the information on
the drawings, specifications and subsequent
instructions

Stairs and landings

A Adult Pool 484 kg

B Central Pool 363 kg

C Club Pool 121 kg

D Kids Pool 121 kg

E Chalet Pool 726 kg

F Sunken Lawn Water Feature 121 kg

Generally

Stairs and landings

G External Steps 7623 kg

SHUTTERING

Temporary shuttering for cast in situ concrete;


smooth finish

H Sides and soffits slabs 248 m2

J Sides of walls 85 m2

K Adult Pool 378 m2

L Central Pool 230 m2

M Club Pool 215 m2

N Kids Pool 45 m2

To Collection

Bill No. 6 - Page 14


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

SHUTTERING

Temporary shuttering for cast in situ concrete;


smooth finish

Sides of walls

A Chalet Pool 147 m2

B Arrival Court Feature 120 m2

C Water Channel 136 m2

D Ornamental Lake Feature 408 m2

E Ornamental Stream Feature 142 m2

F Water Feature 2 23 m2

G Courtyard Water Feature 12 m2

H Light Well Feature 33 m2

J Stone-clad retaining / planter wall 11123 m2

K Stone-clad free standing wall 295 m2

L Rendered concrete retaining wall 3295 m2

M Rendered concrete free standing wall 187 m2

N Cascade stone-clad feature wall 52 m2

P Stone-clad wall 392 m2

Q Stairs and landings, including treads, risers,


strings and sloping soffits 1 m2

R Adult Pool 25 m2

S Central Pool 26 m2

T Club Pool 7 m2

U Kids Pool 7 m2

V Chalet Pool 46 m2

Sides of Pool Slab

W Adult Pool 16 m2

X Central Pool 36 m2

Y Club Pool 19 m2

Z Kids Pool 9 m2

To Collection

Bill No. 6 - Page 15


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

SHUTTERING

Temporary shuttering for cast in situ concrete;


smooth finish

Sides of Pool Slab

A Chalet Pool 5 m2

B Arrival Court Feature 6 m2

C Water Channel 28 m2

D Ornamental Lake Feature 120 m2

E Ornamental Stream Feature 35 m2

F Water Feature 2 15 m2

G Courtyard Water Feature 1 m2

H Light Well Feature 11 m2

Generally

J Sides of columns 295 m2

K Security Hut 10 m2

L Sides and soffits of beams 30 m2

M Sides of Seating 87 m2

SUNDRIES

Expansion Joints;Including all seals, cover plates, as


required

N Adult Pool 106 m

P Central Pool 243 m

Q Club Pool 127 m

R Kids Pool 60 m

To Collection

Bill No. 6 - Page 16


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION C - CONCRETE WORK

SUNDRIES

Expansion Joints;Including all seals, cover plates, as


required

A Chalet Pool 27 m

SECTION D - MASONRY

WALLS AND PIERS

Boulder work to be stacked up as drystone wall

1000mm width naturalistic drystone boulder wall; height vary

B Generally 119 m

SECTION E - METALWORK

STRUCTURAL METALWORK

Steel Posts; Supply and fix 250 x 250 x 500 size


steel posts including finish as specified; complete
with all fixings, angles, abutments, closures,
flashings, sealant, membranes as necessary for
complete installation

Posts

C Bridge Type 1 20 no

D Bridge Type 2 6 no

Steelwork; Supply and fix 250 x 75 size box type


steel beams, complete with all fixings, angles,
abutments, closures, flashings, sealant, membranes
as necessary for complete installation

Beams

E Bridge Type 1 65 m

F Bridge Type 2 13 no

Steelwork; Supply and fix 75 x 75 size powder


coated white galvanized steel support including all
associated complete with all fixings, angles,
abutments, closures, flashings, sealant, membranes
as necessary for complete installation

Supports

G Shade Structures 58 m

To Collection

Bill No. 6 - Page 17


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION E - METALWORK

NON - STRUCTURAL METALWORK

Hand Rail System; fixing to concrete with anchors,


including all glazing, fixtures, stainless steel hand rail
and finishes as required; As per Dwg No.
5310/A/SD1/020

Walls

A 50 dia 28 m

Pool Ladders; Including all necessary fixings,


waterproofing, finishes, bars, grab rails as required

Ladders

B Central Pool ITEM

Water Tanks; Stainless steel reservoir to concrete


shell for water supply to features, including all
reinforcement, waterproofing, pumps, hoses and
piping as required

Generally

C Courtyard Water Feature ITEM

Steel Panels; Supply and fix 150mm thick powder


coated white galvanized steel panel Including all
fixings, angles, abutments, closures, flashings,
sealant, insulation, membranes as required for
complete installation

Panels

D Shade Structures 133 m2

To Collection

Bill No. 6 - Page 18


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION F - WOODWORK

STRUCTURAL TIMBERS

Timber Posts; 50 x 50 size timber posts; Including all


necessary fixings and finishes as required

Timber Posts

A Shade Structures 187 m

Timber Posts; 75 x 75 size timber posts; Including all


necessary fixings and finishes as required

Timber Posts

B Shade Structures 13 m

Timber Posts; 200 x 200 size halved jointed


hardwood timber; Including all necessary fixings and
finishes as required

Timber Posts

C Colonnade 125 m

Timber Beams

D Colonnade 118 m

Timber Posts; 200 x 85 size timber frame fixed to


concrete structure; Including all necessary fixings
and finishes as required

Timber Structures

E Porte Cochere 39 m

Timber Posts; 400 x 85 size timber frame fixed to


concrete structure; Including all necessary fixings
and finishes as required

Timber Structures

F Porte Cochere 148 m

To Collection

Bill No. 6 - Page 19


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION F - WOODWORK

STRUCTURAL TIMBERS

Timber; 50 x 150 size timber battens; Including all


necessary fixings and finishes as required

Timber Battens

A Shade Structures 676 m

Timber; 50 x 100 size timber battens; Including all


necessary fixings and finishes as required

Timber Battens

B Shade Structures 93 m

C Playground Structures 95 no

Timber; 75 x 150 size timber battens; Including all


necessary fixings and finishes as required

Timber Battens

D Shade Structures 6 m

Timber; 100 x 100 size timber beam bolted to top of


posts with steel brackets; Including all necessary
fixings and finishes as required

Timber Beams

E Security Hut 14 m

Timber; 100 x 150 size timber beam bolted to top of


posts with steel brackets; Including all necessary
fixings and finishes as required

Timber Beams

F Playground Structures 109 no

To Collection

Bill No. 6 - Page 20


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION F - WOODWORK

STRUCTURAL TIMBERS

Timber; 50 x 75mm size timber joists bolted to


timber bearers with stainless steel plates; Including
all necessary fixings and finishes as required

Timber Joists

A Bridge Type 1 195 m

B Bridge Type 2 42 m

Timber; 200 x 200 size timber bearers; Including all


necessary fixings and finishes as required

Timber Bearers

C Bridge Type 1 120 m

D Bridge Type 2 52 m

Timber; 250 x 250 x 2500mm size hardwood timber


post with smooth sawn finish and concrete footings;
Including all necessary fixings and finishes as
required

Timber Structures

E Shade Structures 16 no

F Shade Structures; curved 14 no

G Pathway Structures 50 no

Timber; 200 x 200 x 2750 size hardwood timber


posts with reinforced concrete footing; Including all
necessary fixings and finishes as required

Timber Structures

H Playground Structures 16 no

To Collection

Bill No. 6 - Page 21


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION F - WOODWORK

STRUCTURAL TIMBERS

Timber; 150 x 100 size timber beam bolted to top of


posts with steel brackets; Including all necessary
fixings and finishes as required

Timber Beams

A Shade Structures 37 m

B Pathway Structures 82 no

Timber; 150 x 75 size timber beam bolted to top of


posts with steel brackets; Including all necessary
fixings and finishes as required

Timber Beams

C Shade Structures; curved 27 m

Timber; 25 x 50 size decorative hardwood timber


slats; Including all necessary fixings and finishes as
required

Timber Slats

D Colonnade 234 m

Timber; 50 x 50 size horizontal timber slats;


Including all necessary fixings and finishes as
required

Timber Slats

E Colonnade 120 m

Timber; 75 x 50 size vertical timber slats; Including


all necessary fixings and finishes as required

Timber Slats

F Colonnade 2080 m

To Collection

Bill No. 6 - Page 22


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION F - WOODWORK

STRUCTURAL TIMBERS

Timber; 100 x 50 size timber slats fixed to top of


shade structure with recessed steel plates; Including
all necessary fixings and finishes as required

Timber Slats

A Shade Structures 244 m

B Shade Structures; curved 180 m

C Security Hut 132 m

Timber; 150 x 100 size timber slats fixed to top of


shade structure with recessed steel plates; Including
all necessary fixings and finishes as required

Timber Slats

D Pathway Structures 769 no

Timber; 200 x 40 size timber slats; Including all


necessary fixings and finishes as required

Timber Slats

E Porte Cochere 373 m

To Collection

Bill No. 6 - Page 23


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION F - WOODWORK

BOARDING AND FLOORING

Timber Decking; Timber Boardwalk, including 200 x 70 x


2500 mm size seasoned hardwood timber board with
grooved anti-slip finish to upper face fixed with 4 nos.
stainless steel bolts, 200 x 70 mm size seasoned
hardwood timber joists fixed to posts with 2 no's stainless
steel bolts, 200 x 200 mm size seasoned hardwood
timber posts as required to a complete with Including all
necessary fixings and finishes as shown on the Drawing
No. 179-DD-613

Flooring

A Walkways 309 m2

Timber Decking; 200-225 x 25 size timber decking


screwed to timber joists and have rough sawn non
slip finish with light gray varnish; Including all
necessary fixings and finishes as required

Flooring

B Bridge Type 1 91 m2

C Bridge Type 2 21 m2

FINISHINGS AND FITTINGS

Timber Cladding; 25 thick timber cladding to


structural timbers; Including all necessary fixings and
finishes

Bridge Type 1

D Generally 145 m2

Bridge Type 2

E Generally 29 m2

To Collection

Bill No. 6 - Page 24


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION F - WOODWORK

FINISHINGS AND FITTINGS

Timber Rods; 50mm dia circular timber rods;


Including all necessary fixings and finishes

Shade Structures

A Generally 1541 m

50 diameter hardwood handrail at 75 from face of


wall and 900 high above adjacent step; hand rail
connected to stain polished stainless steel backet
with concealed fixing spacing of brackets as per
Engineer's requirements

Handrail

B 50 dia 970 m

COMPOSITE ITEMS

Handrails and Balustrades; 200 x 200 x 1100 size


timber post to handrail including the concrete footing;
Including all necessary fixings and finishes as
required

Balustrades and Handrails

C Generally 20 no

SECTION G - THERMAL AND MOISTURE


PROTECTION

WATERPROOFING

Waterproofing; 5 mm thick SBS waterproof


membrane including all fillers, abutments, angles,
working around obstructions and the like

Landscaped Areas

D Horizontally 5839 m2

E Vertically 1507 m2

To Collection

Bill No. 6 - Page 25


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION G - THERMAL AND MOISTURE
PROTECTION

WATERPROOFING

Waterproofing layers and Membranes; Flurodrain


FD40 water retention system; As per Dwg No.
179-DD-704

Landscaped Areas

A Horizontally 815 m2

Waterproofing layers and Membranes; Terram 1000


or approved geo textile layer; As per Dwg No.
179-DD-704

Landscaped Areas

Horizontally

B Podium 815 m2

C Peninsula 605 m2

Waterproofing layers and Membranes; Filter


sheet/fleece to be wrapped around edge of planter;
As per Dwg No. 179-DD-704

Landscaped Areas

D Generally 362 no

Waterproofing layers and Membranes; Approved


geo textile membrane to all sides and bottom of root
ball; As per Dwg No. 179-DD-704

Landscaped Areas

E Generally 2124 m2

To Collection

Bill No. 6 - Page 26


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION G - THERMAL AND MOISTURE
PROTECTION

INSULATION

Insulation; As per Dwg No. 178-DD-704

Landscaped Areas

A Horizontally 815 m2

SECTION H - DOORS AND WINDOWS

SCREENS

Privacy Screen; 2500 x 600 size privacy screen on


heavy duty stainless steel/aluminium trackes, fixed
and flush with timber beams above and below
opening including all necessary accessories, finishes
and ironmongeries

Privacy Screens

B Generally 8 no

SECTION J - FINISHES

BACKGROUNDS (EXTERNALLY)

Cement Screed; Sand cement

Screeds

C on floors; 50 thick 3217 m2

D Floors; 50mm thick to falls, crossfalls and cambers 71 m2

E Under typical stone clad steps 287 m2

Render; White coloured render to concrete surfaces

F on walls; 18 mm thick 7533 m2

To Collection

Bill No. 6 - Page 27


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (INTERNALLY)

Carpet tiles; Including adhesives, trowelable levelling


and patching compound, edgings, gripper rods,
fixings

Floors

A F1 39 m2

FINISHINGS (EXTERNALLY)

Tiles; 100 x 100 x 4 sized blue/blue green/ turquoise


pool tiles; Including all mortar and beddings

Floors

B Generally 2467 m2

Walls

C Generally 764 m2

Granite Tiles; 250 x 400-600 x 40 light grey granite;


Including all mortar and beddings

Floors

D Generally 69 m2

E e/o for 10 width safety grooved 55 m

Dark Granite Tiles; 300 x 300 x 50 dark granite tiles


with honed finish; Including all mortar and beddings

Floors

F Generally 17 m2

Dark Granite Tiles; 300 x 300 x 20 dark granite tiles


with honed finish; Including all mortar and beddings

Floors

G Generally 294 m2

To Collection

Bill No. 6 - Page 28


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (EXTERNALLY)

Granite Tiles; 300 x 300 x 50 light granite tiles with


honed finish; Including all mortar and beddings

Floors

A Generally 12 m2

Granite Tiles; 200 x 200 x 20 dark grey granite tiles


with natural finish; Including all mortar and beddings

Floors

B Generally 252 m2

Walls

C Generally 140 m2

Granite Tiles; 300 x 300 x 20 dark grey granite tiles


with natural finish; Including all mortar and beddings

Floors

D Generally 13 m2

Walls

E Generally 25 m2

Granite Tiles;300-600x40x150mm light grey granite


riser to steps with bush hammered non slip finish;
Including all mortar and beddings; As per Dwg No.
179-DD-300-301

Staircase treads, risers, edges or the like

F Generally 287 m2

To Collection

Bill No. 6 - Page 29


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (EXTERNALLY)

Granite Tiles; 100 x 100 x 20 dark grey granite tiles;


Including all mortar and beddings

Floors

A Generally 42 m2

Walls

B Generally 31 m2

Granite Tiles;100 x 200 x 20 dark grey granite tiles;


Including all mortar and beddings

Walls

C Generally 16 m2

Granite Tiles; Base of structure to be clad in random


sizes light grey granite paving with 200 x 500 x 40
border.; Including all mortar and beddings

Floors

D Generally 14 m2

Sandstone Cladding; light grey colour, to concrete


wall.; Including all mortar and beddings

Walls

E Generally 275 m2

Sandstone Cladding; 20 thick light grey sandstone


cladding to front face of water feature to match
typical walls; Including all mortar and beddings

Walls

F Generally 5 m2

To Collection

Bill No. 6 - Page 30


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (EXTERNALLY)

Sandstone Cladding; Including all mortar and


beddings; As per Dwg No. 179-DD-300-301

Staircase treads, risers, edges or the like

A Generally 63 m2

Sandstone Cladding; 300-500 x 50-110 x 30 thick


light grey granite mortared to front face of water
feature; Water to cascade down front face; Including
all mortar and beddings

Walls

B Generally 4 m2

Sandstone Cladding; 300-600 x 250 x 20 thick light


grey granite; Including all mortar and beddings

Seating

C Generally 63 m2

Retaining wall/ planter wall and free standing wall

D Generally 6152 m2

Sandstone Cladding; 400-490 x 620 x 100 thick light


grey granite; Including all mortar and beddings

Seating

E Generally 88 m2

Sandstone Cladding; Typical sandstone clad


concrete wall to water feature with 40 thick light grey
sandstone coping; Including all mortar and beddings

Walls

F Generally 16 m2

To Collection

Bill No. 6 - Page 31


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

FINISHINGS (EXTERNALLY)

Resin FInish; resin applied finish to form water


resistant barrier

Floors

A Generally 1786 m2

Water feature to have pebbles and mortared to base


with smaller stones and sand infill; All stone boulders
and gravel to be dark grey to approval of Engineer;
As per Dwg no. 179-DD-406-407

Floors

B Ornamental Water Feature ITEM

Cascades will vary in height depending on location


between 800-1200 high as required; As per Dwg no.
179-DD-406-407

Walls

C Generally ITEM

Cascade to fall with constant force along all entire


width of feature forming a 5mm deep continuous
water curtain over the stone; As per Dwg no.
179-DD-410

Walls

D Generally ITEM

SUNDRIES (EXTERNALLY)

Coping; 100 x 100 x 20 dark grey granite tiles to


base and sides; Including all mortar and beddings

Courtyard Feature

E Generally 8 m

To Collection

Bill No. 6 - Page 32


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

SUNDRIES (EXTERNALLY)

Coping; 200 x 500 x 40 light grey sandstone coping


with natural finish; Including all mortar and beddings

Playground

A Generally 23 m

Coping; 300 x 100 x 40 light grey sandstone coping


with natural finish; Including all mortar and beddings

Seating

B Generally 61 m

Walls

B Generally 4886 m

Coping; 300 x 200 x 100 light grey granite coping


with natural finish; Including all mortar and beddings

Lawn Feature

C Generally 54 m

Coping; 400 x 800 x 80-100 sized (angled top face of


block) light grey granite, with bush hammered non
slip finish to pool edge; Including all mortar and
beddings

Adult Pool

D Generally 106 m

Coping; 200 x 200 x 40 light grey sandstone coping


with natural finish; Including all mortar and beddings

Water Channel

E Generally 113 m

To Collection

Bill No. 6 - Page 33


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

SUNDRIES (EXTERNALLY)

Coping; 300 x 300 x 100 dark grey granite infinity


edge with smooth finish; Including all mortar and
beddings

Water Feature 2

A Generally 14 m

Coping; 325 x 850 angled profiler light grey granite


coping stone with polished finish; Including all mortar
and beddings

Ornamental Lake Feature

B Generally 236 m

Coping; 400 x 400 x 100 sized light grey granite;


Including all mortar and beddings

Central Pool

C Generally 343 m

Club Pool

D Generally 127 m

Kids Pool

E Generally 60 m

Coping; 500 x 45-70 x 300 dark light grey granite


with 10 bull nose and honed finish; Including all
mortar and beddings

Arrival Court

F Generally 49 m

To Collection

Bill No. 6 - Page 34


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION J - FINISHES

SUNDRIES (EXTERNALLY)

Coping; 180 x 45-70 x 200 dark light grey granite


with 10 bull nose and honed finish; Including all
mortar and beddings

Arrival Court

A Generally 14 m

Coping; 300 x 200 x 40 light grey sandstone coping


with natural finish; Including all mortar and beddings

Water Channel

B Generally 113 m

Coping; 400 x 100 x 500-700 light grey sandstone


coping with smooth finish to terrace as seating;
coping to have 50 overhand and to be up lit from
water feature below; Including all mortar and
beddings

Ornamental Lake Feature

C Generally 285 m

Coping; 600 x 600 x 100 light grey sandstone coping


mortared to rear edge of concrete structure;
Including all mortar and beddings

Courtyard Feature

D Generally 2 m

To Collection

Bill No. 6 - Page 35


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

IRRIGATION SYSTEM

Under ground and above ground irrigation system-furnish and


install all planting water piping system as shown on the
drawings and/or as specified including but not limited to all
excavated trench and laid drainage pipework complete piping,
drains, vents, fittings, angles, ells, tees, reducers, insulation,
supports and any other items required for a complete
installation as indicated;including bed and surround,selected
fine fill,back filling over with selected excavated material and
disposal warning tapes etc . Testing and commisioning shall
be included in all rates.

Pipes

A 50mm/32mm MDPE lateral header pipework 8,432 m

B 32mm MDPE lateral pipework 537 m

C 50mm MDPE lateral pipework 1,920 m

63mm MDPE 12 bar rated mainline pipework c/w signal


D cable duct and signal cable 1,450 m

90mm HDPE 12 bar rated mainline pipework c/w signal cable


E duct and signal cable 931 m

125mm HDPE 12 bar rated mainline pipework c/w signal


F cable duct and signal cable 1,257 m

G 180mm HDPE 12 bar rated mainline pipework c/w signal


cable duct and signal cable 606 m

H 225mm HDPE 12 bar rated mainline pipework c/w signal


cable duct and signal cable 113 m

J Pressure compensating non leakage dripline pipework 27,367 m

To Collection

Bill No. 6 - Page 36


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

IRRIGATION SYSTEM

Under ground and above ground irrigation system-furnish and


install all planting water piping system as shown on the
drawings and/or as specified including but not limited to all
excavated trench and laid drainage pipework complete piping,
drains, vents, fittings, angles, ells, tees, reducers, insulation,
supports and any other items required for a complete
installation as indicated;including bed and surround,selected
fine fill,back filling over with selected excavated material and
disposal warning tapes etc . Testing and commisioning shall
be included in all rates.

Valves

A Solenoid valve; type D 256 nr

B Solenoid valve; type T 71 nr

C Solenoid valve; type TD 79 nr

D Solenoid valve; type TB 3 nr

E Solenoid valve; type TS 8 nr

F Mainline isolation valves 25 nr

G Solenold valve assembly C/W 159 nr

Sprinkler

H Rain bird 1806 SAM 10 VAN 487 nr

J Rain bird 1806 SAM 12 VAN 61 nr

K Rain bird 1806 SAM 6 VAN 22 nr

L Rain bird 5004 #2.0 SAM 5 nr

M Rain bird 5004 #4.0 SAM 6 nr

N Rain bird 5004 SAM MPR-25 2 nr

P Rain bird 5004 SAM MPR-30 142 nr

Q Rain bird 5004 #6.0 SAM 149 nr

R Tree bubbler 32 nr

S Tree drip necklace 695 nr

T Tree spray 40 nr

To Collection

Bill No. 6 - Page 37


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

ADULT POOL

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 65mm uPVC pipe 80 m

B 80mm uPVC pipe 30 m

C 100mm uPVC pipe 30 m

D 160mm uPVC pipe 18 m

E 200mm uPVC pipe 50 m

F 250mm uPVC pipe 30 m

Valves

G 80mm Gate Valve 1 nr

H 100mm Gate Valve 3 nr

J 160mm Gate Valve 1 nr

K 200mm Gate Valve 3 nr

L 200mm Control Valve 2 nr

M 80mm Double Regulating Valve 1 nr

N 160mm Double Regulating Valve 1 nr

P 200mm Double Regulating Valve 1 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

Q Anti entrapment main drain 500x500 Stainless 2 nr


Steel

To Collection

Bill No. 6 - Page 38


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

ADULT POOL

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

A 160mm dia overflow drain 1 Item

B Vaccum fitting 5 nr

C Wall inlet 12 nr

D Floor inlet 6 nr

E Plant room channel drain 1 Item

F 1200mm dia sand filter 3 nr

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, cabinets, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

G 18m3 Capacity 1 nr

Pumps

H Filtration pump assembly; (Capacity 63 m3/h at


20m head, 2 Duty + 1 Standby) 1 nr

J Dosing pump set (Ph and Bromine - 0.5kW) 1 nr

K UV Ionization system (123 m3/h) 1 nr

L Heat cool pump (101 kW) 1 nr

To Collection

Bill No. 6 - Page 39


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

LIGHTING

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Pool monitoring unit 1 nr

D Control panel 1 nr

To Collection

Bill No. 6 - Page 40


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

FAMILY AND KIDS POOL

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 65mm uPVC pipe 550 m

B 80mm uPVC pipe 80 m

C 100mm uPVC pipe 85 m

D 200mm uPVC pipe 30 m

E 300mm uPVC pipe 170 m

Valves

F 100mm Isolation Valve 1 nr

G 80mm Gate Valve 1 nr

H 100mm Gate Valve 2 nr

J 300mm Gate Valve 6 nr

K 300mm Control Valve 2 nr

L 80mm Double Regulating Valve 1 nr

M 300mm Double Regulating Valve 2 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

N Anti entrapment main drain 500x500 Stainless 4 nr


Steel

P 300mm dia overflow drain 1 Item

Q Vaccum fitting 9 nr

R Wall inlet 40 nr

To Collection

Bill No. 6 - Page 41


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

FAMILY AND KIDS POOL

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

A Floor inlet 16 nr

B Plant room channel drain 1 Item

C 1200mm dia sand filter 8 nr

D PVC/GRP Spill Palletes 1 Item

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

E 64m3 Capacity 1 nr

F 18m3 Capacity; under ground tank 1 nr

Pumps

G Submersible Transfer Pump Set(197 m3/h


@ 15m head each; 2 Duty +1 stanby) 1 nr

H Filtration pump assembly; (Capacity 98 m3/h at


22m head, 4 Duty + 1 Standby) 1 nr

J Dosing pump set (Ph and Bromine - 0.5kW) 1 nr

K UV Ionization system (394 m3/h) 1 nr

L Heat cool pump set (143 kW) 2 nr

To Collection

Bill No. 6 - Page 42


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

LIGHTING

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Pool monitoring unit 1 nr

D Control panel 1 nr

To Collection

Bill No. 6 - Page 43


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

PLUNGE POOL

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 25 m

B 65mm uPVC pipe 60 m

C 100mm uPVC pipe 25 m

Valves

D 50mm Isolation Valve (NC) 1 nr

E 50mm Gate Valve 2 nr

F 65mm Gate Valve 6 nr

G 65mm Control Valve 2 nr

H 65mm Double Regulating Valve 3 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

J Anti entrapment main drain 150mm dia Stainless 2 nr


Steel

K 110mm dia overflow drain 1 Item

L Vaccum fitting 1 nr

M Wall inlet 2 nr

N Plant room drain 2 nr

P 600mm dia sand filter 1 nr

Q PVC/GRP spill palletes 1 Item

To Collection

Bill No. 6 - Page 44


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

PLUNGE POOL

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

A 2.5m3 Capacity 1 nr

Pumps

B Filtration pump assembly; (Capacity 10m3/h at


20m head, 1 Duty + 1 Standby) 1 nr

C Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

D UV Ionization system (10 m3/h) 1 nr

E Heater (24 kW) 1 nr

To Collection

Bill No. 6 - Page 45


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

PLUNGE POOL

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Pool monitoring unit 1 nr

D Control panel 1 nr

To Collection

Bill No. 6 - Page 46


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

PLUNGE POOL (1)

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 25 m

B 65mm uPVC pipe 60 m

Valves

C 50mm Isolation Valve (NC) 1 nr

D 50mm Gate Valve 6 nr

E 65mm Gate Valve 1 nr

F 50mm Control Valve 2 nr

G 50mm Double Regulating Valve 2 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

H Anti entrapment main drain 150mm dia Stainless 2 nr


Steel

J 110mm dia overflow drain 9 m

K Wall inlet 2 nr

L 450mm dia sand filter 1 nr

M PVC/GRP spill palletes 1 Item

To Collection

Bill No. 6 - Page 47


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

PLUNGE POOL (1)

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

A 0.6m3 Capacity 1 nr

Pumps

B Filtration pump assembly; (Capacity 5m3/h at


18m head, 1 Duty + 1 Standby) 1 nr

C Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

D UV Ionization system (5m3/h) 1 nr

E Heater (12 kW) 1 nr

To Collection

Bill No. 6 - Page 48


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

PLUNGE POOL (1)

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Pool monitoring unit 1 nr

D Control panel 1 nr

To Collection

Bill No. 6 - Page 49


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

PLUNGE POOL (2)

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 60 m

B 65mm uPVC pipe 25 m

Valves

C 50mm Isolation Valve 1 nr

D 50mm Gate Valve 1 nr

E 65mm Gate Valve 1 nr

F 50mm Control Valve 2 nr

G 50mm Double Regulating Valve 2 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

H Anti entrapment main drain 150mm dia Stainless 2 nr


Steel

J 110mm dia overflow drain 9 m

K Wall inlet 2 nr

L 450mm dia sand filter 1 nr

M PVC/GRP spill palletes 1 Item

To Collection

Bill No. 6 - Page 50


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

PLUNGE POOL (2)

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

A 2.5m3 Capacity 1 nr

Pumps

B Filtration pump assembly; (Capacity 5m3/h at


18m head, 1 Duty + 1 Standby) 1 nr

C Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

D UV Ionization system (5m3/h) 1 nr

E Heater (12 kW) 1 nr

To Collection

Bill No. 6 - Page 51


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

PLUNGE POOL (2)

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Pool monitoring unit 1 nr

D Control panel 1 nr

To Collection

Bill No. 6 - Page 52


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

EXECUTIVE POOL

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 65mm uPVC pipe 40 m

B 80mm uPVC pipe 25 m

C 100mm uPVC pipe 20 m

D 150mm uPVC pipe 95 m

E 200mm uPVC pipe 25 m

Valves

F 65mm Gate Valve 2 nr

G 80mm Gate Valve 1 nr

H 100mm Gate Valve 2 nr

J 150mm Gate Valve 3 nr

K 150mm Control Valve 2 nr

L 80mm Double Regulating Valve 1 nr

M 150mm Double Regulating Valve 2 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

N Anti entrapment main drain 300X300mm Stainless 2 nr


Steel

P 160mm dia overflow drain 1 Item

Q Vaccum fitting 4 nr

To Collection

Bill No. 6 - Page 53


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

EXECUTIVE POOL

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

A Wall inlet 10 nr

B 900mm dia sand filter 3 nr

C Sump Pit 450x450x300 with water leak detector/sensor 1 nr

D PVC/GRP Spill Palletes 1 Item

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

E 13m3 Capacity 1 nr

Pumps

F Filtration pump assembly; (Capacity 42m3/h at


25m head, 2 Duty + 1 Standby) 1 nr

G Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

H UV Ionization system (84m3/h) 1 nr

J Heat cool pump (45 kW) 1 nr

To Collection

Bill No. 6 - Page 54


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

EXECUTIVE POOL

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Pool monitoring unit 1 nr

D Control panel 1 nr

To Collection

Bill No. 6 - Page 55


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

CHALET POOL

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 100 m

B 65mm uPVC pipe 450 m

C 80mm uPVC pipe 200 m

Valves

D 50mm Gate Valve 15 nr

E 65mm Gate Valve 20 nr

F 80mm Gate Valve 5 nr

G 65mm Control Valve 10 nr

H 65mm Double Regulating Valve 10 nr

J 80mm Double Regulating Valve 5 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

K Anti entrapment main drain 200mm Stainless 2 nr


Steel

L 110mm dia overflow drain 1 Item

M Vaccum fitting 2 nr

N 500mm dia sand filter 1 nr

P Sump Pit 450x450x300 with water leak detector/sensor 1 nr

Q PVC/GRP Spill Palletes 1 Item

To Summary

Bill No. 6 - Page 56


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

CHALET POOL

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

A 1.8m3 Capacity 5 nr

Pumps

B Filtration pump assembly; (Capacity 7.5m3/h at


20m head, 1 Duty + 1 Standby) 1 nr

C Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

D UV Ionization system (7.5m3/h) 1 nr

E Heat cool pump (6.1 kW) 1 nr

To Summary

Bill No. 6 - Page 57


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

CHALET POOL

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Pool monitoring unit 1 nr

D Control panel 1 nr

To Summary

Bill No. 6 - Page 58


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

CASCADE POOL

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 35 m

A 65mm uPVC pipe 70 m

B 100mm uPVC pipe 65 m

C 150mm uPVC pipe 5 m

D 160mm uPVC pipe 30 m

Valves

E 50mm Gate Valve 2 nr

F 65mm Gate Valve 3 nr

G 100mm Gate Valve 1 nr

H 150mm Gate Valve 1 nr

J 150mm Control Valve 1 nr

K 65mm Double Regulating Valve 1 nr

L 100mm Double Regulating Valve 1 nr

M 150mm Double Regulating Valve 1 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

N Anti entrapment main drain 300X300 mm Stainless 2 nr


Steel

P 110mm dia overflow drain 1 Item

To Collection

Bill No. 6 - Page 59


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

CASCADE POOL

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

A Vaccum fitting - nr

B Water Feature Inlet 3 nr

C Jet Inlet(Hydro Massage) 1 nr

D 750mm dia sand filter 1 nr

E Sump Pit 450x450x300 with water leak detector/sensor 1 nr

F PVC/GRP spill palletes 1 Item

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

G 3m3 Capacity 1 nr

Pumps

H Filtration pump assembly; (Capacity 15m3/h at


22m head, 1 Duty + 1 Standby) 1 nr

J Massage/Jet pump assembly; (Capacity 36m3/h at


25m head, 1 Duty + 1 Standby) 1 nr

K Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

L UV Ionization system (15m3/h) 1 nr

M Heat cool pump (13.5 kW) 1 nr

To Collection

Bill No. 6 - Page 60


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

CASCADE POOL

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Pool monitoring unit 1 nr

D Control panel 1 nr

To Collection

Bill No. 6 - Page 61


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

Ornamental lake & ornamental stream

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 65mm uPVC pipe 400 m

B 80mm uPVC pipe 140 m

C 110mm uPVC pipe 200 m

D 150mm uPVC pipe 100 m

E 160mm uPVC pipe 70 m

F 200mm uPVC pipe 300 m

G 300mm uPVC pipe 70 m

Valves

H 80mm Isolation Valve (NC) 1 nr

J 80mm Gate Valve 2 nr

K 100mm Gate Valve 3 nr

L 160mm Gate Valve 3 nr

M 200mm Gate Valve 1 nr

N 150mm Control Valve 1 nr

P 200mm Control Valve 1 nr

Q 80mm Double Regulating Valve 1 nr

R 160mm Double Regulating Valve 1 nr

S 200mm Double Regulating Valve 1 nr

To Collection

Bill No. 6 - Page 62


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

Ornamental lake & ornamental stream

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows, tees,
reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

A Anti entrapment main drain 10 nr

B 110mm dia overflow drain 100 m

C Vaccum fitting 17 nr

D Water Feature Inlet 16 nr

E 1050mm dia sand filter 2 nr

F Sump Pit 450x450x300 with water leak detector/sensor 1 nr

G PVC/GRP Spill Palletes 1 Item

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

H 11m3 Capacity 1 nr

Pumps

J Filtration pump assembly; (Capacity 37.5m3/h at


15m head, 2 Duty + 1 Standby) 1 nr

K River effect pump assembly; (Capacity 75m3/h at


15m head, 1 Duty + 1 Standby) 1 nr

L Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

To Collection

Bill No. 6 - Page 63


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

Ornamental lake & ornamental stream

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C WF Control panel 1 nr

To Collection

Bill No. 6 - Page 64


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

COLONADE WATER CHANNEL 1

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 20 m

B 65mm uPVC pipe 500 m

C 80mm uPVC pipe 45 m

Valves

D 50mm Gate Valve 2 nr

E 65mm Gate Valve 1 nr

F 80mm Gate Valve 5 nr

G 80mm Control Valve 2 nr

H 65mm Double Regulating Valve 1 nr

J 80mm Double Regulating Valve 2 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows,
tees, reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

K Anti entrapment main drain 2 nr

L 110mm dia overflow drain 1 Item

M Vaccum fitting 6 nr

N Water Feature Inlet 4 nr

P 900mm dia sand filter 1 nr

Q Plant room drain 1 nr

R Water Feature jet Inlet 5 nr

S PVC/GRP Spill Palletes 1 Item


To Collection

Bill No. 6 - Page 65


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

COLONADE WATER CHANNEL 1

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

A 3m3 Capacity 1 nr

Pumps

B Filtration pump assembly; (Capacity 22m3/h at


16m head, 1 Duty + 1 Standby) 1 nr

C Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

To Collection

Bill No. 6 - Page 66


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

COLONADE WATER CHANNEL 1

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Control panel 1 nr

To Collection

Bill No. 6 - Page 67


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

COLONADE WATER CHANNEL 2

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 20 m

B 65mm uPVC pipe 420 m

C 80mm uPVC pipe 25 m

D 100mm uPVC pipe 20 m

Valves

E 50mm Isolation Valve (NC) 1 nr

F 80mm Isolation Valve (NC) 1 nr

G 50mm Gate Valve 1 nr

H 65mm Gate Valve 1 nr

J 80mm Gate Valve 3 nr

K 80mm Control Valve 2 nr

L 65mm Double Regulating Valve 1 nr

M 80mm Double Regulating Valve 2 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows,
tees, reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

N Anti entrapment main drain 2 nr

P 110mm dia overflow drain 200 m

Q Vaccum fitting 6 nr

To Collection

Bill No. 6 - Page 68


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

COLONADE WATER CHANNEL 2

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows,
tees, reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

A Water Feature Inlet 4 nr

B Water Feature jet Inlet 5 nr

C 900mm dia sand filter 1 nr

D Plant room drain 1 nr

E PVC/GRP Spill Palletes 1 Item

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

F 3m3 Capacity 1 nr

Pumps

G Filtration pump assembly; (Capacity 20m3/h at


16m head, 1 Duty + 1 Standby) 1 nr

JET Pumps set(18 m3/hr @ 20m Head each) (1 Duty; 1


H nr
Stanby) 1

I Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

To Collection

Bill No. 6 - Page 69


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

COLONADE WATER CHANNEL 2

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Control panel 1 nr

To Collection

Bill No. 6 - Page 70


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

LIGHT WELL WATER FEATURE

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 30 m

B 65mm uPVC pipe 110 m

Valves

C 50mm Gate Valve 3 nr

D 65mm Gate Valve 5 nr

E 65mm Control Valve 1 nr

F 65mm Double Regulating Valve 2 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows,
tees, reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

G Anti entrapment main drain 2 nr

H 110mm dia overflow drain 1 Item

J Vaccum fitting 1 nr

K Water Feature Inlet 1 nr

L 450mm dia sand filter 1 nr

M Plant room drain 1 nr

To Collection

Bill No. 6 - Page 71


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

LIGHT WELL WATER FEATURE

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

A 0.3m3 Capacity 1 nr

Pumps

B Filtration pump assembly; (Capacity 2m3/h at


16m head, 1 Duty + 1 Standby) 1 nr

C Bromine feeder 1 nr

To Collection

Bill No. 6 - Page 72


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

LIGHT WELL WATER FEATURE

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Control panel 1 nr

To Collection

Bill No. 6 - Page 73


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

ARRIVAL COURT WATER FEATURE & REFLECTIVE


WATER FEATURE

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 40 m

B 65mm uPVC pipe 250 m

C 80mm uPVC pipe 40 m

D 100mm uPVC pipe 30 m

E 150mm uPVC pipe 30 m

F 200mm uPVC pipe 30 m

Valves

G 50mm Gate Valve 5 nr

H 65mm Gate Valve 5 nr

J 100mm Gate Valve 1 nr

K 150mm Gate Valve 2 nr

L 50mm Control Valve 1 nr

M 65mm Control Valve 2 nr

N 150mm Control Valve 1 nr

P 50mm Double Regulating Valve 1 nr

Q 65mm Double Regulating Valve 2 nr

R 100mm Double Regulating Valve 1 nr

S 150mm Double Regulating Valve 1 nr

To Collection

Bill No. 6 - Page 74


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

ARRIVAL COURT WATER FEATURE & REFLECTIVE


WATER FEATURE

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows,
tees, reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

A Anti entrapment main drain 150mm dia stainless 5 nr


steel

B 110mm dia overflow drain 1 Item

C Vaccum fitting 4 nr

D Water Feature Inlet 8 nr

E 500mm dia sand filter 1 nr

F 600mm dia sand filter 1 nr

G Plant room drain 1 nr

H Jet nozzel 3 nr

J PVC/GRP spill palletes 1 Item

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

K 4m3 Capacity 1 nr

Pumps

L Filtration pump assembly; (Capacity 8m3/h at


17m head, 1 Duty + 1 Standby) 1 nr

M Filtration pump assembly; (Capacity 11m3/h at


16m head, 1 Duty + 1 Standby) 1 nr
To Collection

Bill No. 6 - Page 75


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

ARRIVAL COURT WATER FEATURE & REFLECTIVE


WATER FEATURE

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

A Fountain pump assembly; (Capacity 60m3/h at


20m head, 1 Duty + 1 Standby) 1 nr

B Dosing pump set (Ph and Bromine - 0.2kW) 2 nr

C Bromine feeder 1 nr

To Collection

Bill No. 6 - Page 76


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

ARRIVAL COURT WATER FEATURE & REFLECTIVE


WATER FEATURE

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Control panel 2 nr

To Collection

Bill No. 6 - Page 77


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

INTERNAL WATER FEATURE 1 & 2

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 30 m

B 65mm uPVC pipe 90 m

C 80mm uPVC pipe 160 m

D 100mm uPVC pipe 80 m

Valves

E 50mm Isolation Valve (NC) 1 nr

F 50mm Gate Valve 1 nr

G 65mm Gate Valve 1 nr

H 80mm Gate Valve 4 nr

J 80mm Control Valve 2 nr

K 65mm Double Regulating Valve 1 nr

L 80mm Double Regulating Valve 2 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows,
tees, reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

M Anti entrapment main drain 150mm dia stainless 6 nr


steel

N 110mm dia overflow drain 1 Item

P Vaccum fitting 6 nr

To Collection

Bill No. 6 - Page 78


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

INTERNAL WATER FEATURE 1 & 2

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows,
tees, reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

A Water Feature Inlet 6 nr

B 600mm dia sand filter 2 nr

C Plant room drain 1 nr

D PVC/GRP spill palletes 1 Item

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

E 3.4m3 Capacity 1 nr

Pumps

F Filtration pump assembly; (Capacity 22m3/h at


16m head, 1 Duty + 1 Standby) 1 nr

G Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

To Collection

Bill No. 6 - Page 79


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

INTERNAL WATER FEATURE 1 & 2

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Control panel 1 nr

To Collection

Bill No. 6 - Page 80


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

SANKEN LAWN WATER FEATURE

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 35 m

B 65mm uPVC pipe 80 m

C 80mm uPVC pipe 35 m

Valves

D 50mm Isolation Valve (NC) 1 nr

E 50mm Gate Valve 2 nr

F 65mm Gate Valve 4 nr

G 65mm Control Valve 2 nr

H 65mm Double Regulating Valve 3 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows,
tees, reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

J Anti entrapment main drain 150mm dia stainless 2 nr


steel

K 110mm dia overflow drain 1 Item

L Vaccum fitting 1 nr

M Water Feature Inlet 2 nr

N 450mm dia sand filter 1 nr

P Sump Pit 450x450x300 with water leak detector/sensor 1 nr

Q PVC/GRP spill palletes 1 Item

To Collection

Bill No. 6 - Page 81


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

SANKEN LAWN WATER FEATURE

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Balance tank

A 1.25m3 Capacity 1 nr

Pumps

B Filtration pump assembly; (Capacity 5m3/h at


15m head, 1 Duty + 1 Standby) 1 nr

C Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

To Collection

Bill No. 6 - Page 82


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

SANKEN LAWN WATER FEATURE

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Control panel 1 nr

To Collection

Bill No. 6 - Page 83


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

Suite entry courtyard

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 20mm uPVC pipe 6 m

B 50mm uPVC pipe 31 m

Valves

C 50mm Gate Valve 5 nr

D 50mm Check Valve 1 nr

E 20mm Water level regulating valve 1 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows,
tees, reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

F Anti Entrapment main drain 200 x 200 stainless steel 2 nr

G Floor Inlet 2 nr

H Cartridge filter(2.7m3/hr) 1 nr

J Chlorine feeder 1 nr

To Collection

Bill No. 6 - Page 84


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

Suite entry courtyard

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Pumps

Filter Feed Pumps set(2.7 m3/hr @ 15m Head each) (1


A 1 nr
Duty; 1 Stanby)

B UV Ionization System Set(394 m3/hr) 1 nr

To Collection

Bill No. 6 - Page 85


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

Suite entry courtyard

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Control panel 1 nr

To Collection

Bill No. 6 - Page 86


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

Colonade Infinity pool

Supply and Install all Piping as shown on the Drawings


and/or as specified including but not limited to all
piping, fitting, angle, elbows, reducers, valves, supports,
insulation as indicated.

Pipes

A 50mm uPVC pipe 25 m

B 80mm uPVC pipe 14 m

Valves

C 50mm Gate Valve 3 nr

D 80mm Gate Valve 2 nr

E 50mm Check Valve 1 nr

F 50mm Double Regulating Valve 1 nr

G 80mm Double Regulating Valve 1 nr

Supply and Install all Devices as shown on the


Drawings and/or as specified including
but not limited to all piping, fittings, angles, elbows,
tees, reducers, associated valves, flex, strainers,
insulation, supports and any other items
required for a complete Installation as indicated

Devices

H Anti entrapment main drain 2 nr

J Overflow drain 1 Item

K Vaccum fitting 1 nr

L Water Feature Inlet 2 nr

M 450 dia Sand filter 1 nr

N Cascade inlet 2 nr

To Collection

Bill No. 6 - Page 87


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - MECHANICAL
ENGINEERING INSTALLATIONS

Colonade Infinity pool

Supply and Install all Equipment as shown on the


Drawings and/or as specified including but not limited
to all piping, tanks, fittings, angles, elbows, tees,
reducers, meters, control panels, supports, associated
valves, gate valve, gauges, flex, strainers,
insulation, float valve, over floor valve, high level
switch, low level switch, ball valve, access door with
ladder, drain, supports and any other items required
for a complete Installation as indicated

Pumps

Filter Feed Pumps set(5 m3/hr @ 15m Head each) (1


A 1 nr
Duty; 1 Stanby)

Cascade Pumps set(5 m3/hr @ 12m Head each) (1 Duty;


B 1 nr
1 Stanby)

C Dosing pump set (Ph and Bromine - 0.2kW) 1 nr

To Collection

Bill No. 6 - Page 88


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED
SECTION Q - ELECTRICAL
ENGINEERING INSTALLATIONS

Colonade Infinity pool

Supply and Install all Lighting Fixtures, Local


Switching and Wiring Points as shown on the
Drawings and/or as specified including but not limited
to all fixtures,,outlets, boxes, switches, plates, trim,
all cables, terminations, containment, mounting,
supports and any other items required for a
complete Installation as indicated.

A Lighting Item

LIGHTING CONTROL SYSTEM

Supply and Install Lighting Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, batteries, design, engineering and any
other items required for a complete Installation as
indicated.

B Lighting control system for swimming pools Item

POOL CONTOL/MONITOR SYSTEM

Supply and Install Control System as


shown on the Drawings and/or as specified including
but not limited to all panels, control boards,
switching, relays, remote controls, plates, trim, all
cables, wiring, terminations, containment, mounting,
supports, design, engineering and any
other items required for a complete Installation as
indicated.

Devices

C Control panel 1 nr

To Collection

Bill No. 6 - Page 89


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

ADDITIONAL ITEMS

The tenderer is to detail below any additional items with


quantities and rates not previously included to complete
the build up to the lump sum tender price for this
section of the works. Should the tenderer fail to insert
any items here it will be deemed that his lump sum
price for the tender includes all items and no
subsequent claim for any additional item will be
entertained.

A ……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..
……………………………………………………………..

To Summary

Bill No. 6 - Page 90


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

Collection

Bill No. 6 - Page 1

Bill No. 6 - Page 2

Bill No. 6 - Page 3

Bill No. 6 - Page 4

Bill No. 6 - Page 5

Bill No. 6 - Page 6

Bill No. 6 - Page 7

Bill No. 6 - Page 8

Bill No. 6 - Page 9

Bill No. 6 - Page 10

Bill No. 6 - Page 11

Bill No. 6 - Page 12

Bill No. 6 - Page 13

Bill No. 6 - Page 14

Bill No. 6 - Page 15

Bill No. 6 - Page 16

Bill No. 6 - Page 17

Bill No. 6 - Page 18

Bill No. 6 - Page 19

Bill No. 6 - Page 20

Bill No. 6 - Page 21

Bill No. 6 - Page 22

Carried Forward

Bill No. 6 - Page 91


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

Brought Forward

Bill No. 6 - Page 23

Bill No. 6 - Page 24

Bill No. 6 - Page 25

Bill No. 6 - Page 26

Bill No. 6 - Page 27

Bill No. 6 - Page 28

Bill No. 6 - Page 29

Bill No. 6 - Page 30

Bill No. 6 - Page 31

Bill No. 6 - Page 32

Bill No. 6 - Page 33

Bill No. 6 - Page 34

Bill No. 6 - Page 35

Bill No. 6 - Page 36

Bill No. 6 - Page 37

Bill No. 6 - Page 38

Bill No. 6 - Page 39

Bill No. 6 - Page 40

Carried Forward

Bill No. 6 - Page 92


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

Brought Forward
Bill No.6 - Page 41

Bill No.6 - Page 42

Bill No.6 - Page 43

Bill No.6 - Page 44

Bill No.6 - Page 45

Bill No.6 - Page 46

Bill No.6 - Page 47

Bill No.6 - Page 48

Bill No.6 - Page 49

Bill No.6 - Page 50

Bill No.6 - Page 51

Bill No.6 - Page 52

Bill No.6 - Page 53

Bill No.6 - Page 54

Bill No.6 - Page 55

Bill No.6 - Page 56

Bill No.6 - Page 57

Bill No.6 - Page 58

Bill No.6 - Page 59

Bill No.6 - Page 60

Bill No.6 - Page 61

Bill No.6 - Page 62

Bill No.6 - Page 63

Bill No.6 - Page 64

Bill No.6 - Page 65

Bill No.6 - Page 66

To Summary

Bill No. 6 - Page 93


Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

Brought Forward
Bill No.6 - Page 67

Bill No.6 - Page 68

Bill No.6 - Page 69

Bill No.6 - Page 70

Bill No.6 - Page 71

Bill No.6 - Page 72

Bill No.6 - Page 73

Bill No.6 - Page 74

Bill No.6 - Page 75

Bill No.6 - Page 76

Bill No.6 - Page 77

Bill No.6 - Page 78

Bill No.6 - Page 79

Bill No.6 - Page 80

Bill No.6 - Page 81

Bill No.6 - Page 82

Bill No.6 - Page 83

Bill No.6 - Page 84

Bill No.6 - Page 85

Bill No.6 - Page 86

Bill No.6 - Page 87

Bill No.6 - Page 88

Bill No.6 - Page 89

Bill No.6 - Page 90

To Summary

Bill No. 6 - Page 93


Bill No. 6 PROVISIONAL SUMS
MAIN CONTRACT
INTERCONTINENTAL RESORT HOTEL
RAK PROPERTIES

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel Rev.01
Mina Al Arab, Ras Al Khaimah 20 Sep. 2017
RAK Properties
ITEM DESCRIPTION QUANTITY UNIT UNIT RATE AMOUNT AED

PROVISIONAL SUMS

Provisional Sums included may be expended totally, in part or not


at all, as directed by the Engineer.

A ID Works Hotel Suites Corridors and Public Areas 93,000,000 P.Sum

B Overheads and Profit ………… %

C Special Attendances ………… %

D Ironmongery (Back of House only) 750,000 P.Sum

E Overheads and Profit ………… %

F Signage and Wayfinding 350,000 P.Sum

G Overheads and Profit ………… %

H Item deleted

J Item deleted

K Kitchen & Laundry Equipment 15,000,000 P.Sum

L Overheads and Profit ………… %

To General Summary

Bill No. 007 / Page 1


Bill No. 8 DAYWORKS
MAIN CONTRACT
INTERCONTINENTAL RESORT HOTEL
RAK PROPERTIES

VOLUME 2 BILLS OF QUANTITIES 20 September 2017


Rev 01
Intercontinental Resort Hotel

RAK Properties
ITEM DESCRIPTION QUANTITY UNIT RATE AMOUNT AED

DAYWORK SCHEDULE

A General

A1 The Main Contractor may be required to execute certain work due to the nature of which the method of
valuation will be on a day work basis.

A2 The Main Contractor is to maintain an accurate record of time spent and materials and plant used for each
separate instruction given. Day work sheets are to be numbered and should describe fully instructions to
which they refer and they are to be summarized, priced and submitted to the Engineer and Program
Manager each week. The submission of such day work sheets does not necessarily mean that the work
will be valued under the relevant clauses of the Conditions of Contract or that any payment is in fact due.

B Labour

B1 The Main Contractor, when tendering, is to give the rates he requires for labourers and craftsmen against
each item stated.

B2 The rates are to be comprehensive and include:

a) Wages and all costs, payments and charges including pensions, annual and public holidays, travelling
time, expenses, fares and transport, guaranteed time, non productive time and other expenses in
connection with overtime, incentive and bonus payments, and other disbursements arising from
employment of labour including redundancy payments, and all obligations of the Employer under
Government legislation.

b) Charges incurred in respect of site and office supervision including foreman's time and extra emoluments
paid to foremen and leading craftsmen and gangers.

c) Site and Head Office overhead charges such as rent, rates, insurances, electricity, gas, fuel, water,
printing, stationery, postage, telephone charges, motor car expenses, renewals, maintenance and
depreciation of premises, machinery, plant and the like.

d) Profit.

C Local Materials

C1 The Main Contractor, when tendering, is to give the rates required for materials against each item stated.

C2 The rates are to be comprehensive and include:

a) Cost of materials including all costs for delivery to site, unloading, storing, transport and protection.

b) Site and Head office overhead charges as defined above.

c) Profit.

C3 Materials used in day works and not listed under Day work Schedule are to be charged at invoice cost. All
discounts are to be allowed to the Employer. Invoices are to be made available to the Program Manager at
the time the relevant day work sheets are submitted.

To Collection
Bill No. 008/ Page 1
Intercontinental Resort Hotel

RAK Properties
ITEM DESCRIPTION QUANTITY UNIT RATE AMOUNT AED

DAYWORK SCHEDULE (…CONT)

C4 The Main Contractor is to allow in the item provided the additional percentage he requires to be added to
the invoice cost of materials to cover all delivery costs to site, including costs for unloading, storing,
transport, protection, overhead charges as previously defined and profit.

D Imported Materials

D1 Invoices are to be made available to the Program Manager at the time the relevant day work sheets are
submitted.

D2 The Main Contractor is to allow in the items provided for the additional percentage he requires to be added
to the invoice price of materials to cover taking delivery, paying all costs, charges and duties, delivery to
site, unloading, storage, overhead charges as previously defined and profit.

D Plant

D1 The Main Contractor is to enter the rates required per hour for plant and machinery against the items stated.

D2 The rates are to be comprehensive and will include:

a) Mobilization and demobilization costs.

b) Fuel, oil, lubricants and all other consumables.

c) Servicing, repairs and replacements.

d) Site and Head office overhead charges as defined above.

e) Profit.

D3 The rates are to be exclusive of attendants and drivers who shall be charged at labour rates set out above.

D4 If the Main Contractor is unable to price the particular type of plant listed, he should price for the nearest
equivalent item available to him and state what has been included in his tender.

D5 The net cost of specialist equipment will be paid with invoice backup plus the percentage included here

E Work Outside Normal Working Hours

E1 The Main Contractor is to include a percentage increase, for labour costs for day work carried out at the
instruction of the Program Manager outside normal working hours.

To Collection
Bill No. 008/ Page 2
Intercontinental Resort Hotel

RAK Properties
ITEM DESCRIPTION QUANTITY UNIT RATE AMOUNT AED

DAYWORKS

Labour

A Forman hr

B Surveyor hr

C Site in charge hr

D Rig Operator hr

E Crane Operator hr

F Anchor Machine Operator hr

G Shovel Operator hr

H Excavator Operator hr

J JCB Operator hr

K Mobile Crain Operator hr

L Welder hr

M Steel Fixer hr

N Mechanic/Fitter hr

P Skilled Labourers hr

Q Unskilled Labours hr

R Mason hr

S Rigger hr

T Electrician hr

U Light Duty Driver hr

V Heavy Duty Driver hr

W Carpenter hr

X Office boy hr

Y Security/Watchman hr

To Collection
Bill No. 008/ Page 3
Intercontinental Resort Hotel

RAK Properties
ITEM DESCRIPTION QUANTITY UNIT RATE AMOUNT AED

Machineries

A JCB hr

B Shovel/ loader hr

C Mobile Crain 25T hr

D Mobile Crain 45T hr

E Excavator hr

F Anchor Machine hr

G Diaphragm wall rig hr

H Piling Rig hr

J Grouting Machine hr

K Dump truck, minimum 10 tonnes hr

L Dump truck, minimum 20 tonnes hr

M Water tanker, minimum 10,000 litres hr

N Compressor hr

P Pick-up truck, 2 tonne hr

Q Water pump, 2 inch. hr

Material hr

R Ordinary Portland cement kg

S Sulphate resistant cement kg

T Ready mix concrete (any grade) delivered to site m3

U Coarse aggregate (dry) t

V Fine aggregate (dry) t

W Building sand t

X 250mm thick hollow concrete blocks nr

To Collection
Bill No. 008/ Page 4
Intercontinental Resort Hotel

RAK Properties
ITEM DESCRIPTION QUANTITY UNIT RATE AMOUNT AED

Machineries

A 200mm thick hollow concrete blocks nr

B 150mm thick hollow concrete blocks nr

C 100mm thick hollow concrete blocks nr

D 200mm thick solid concrete blocks nr

E 100mm thick solid concrete blocks nr

F High yield steel reinforcement bars (any sizes) kg

G Add for Profit and Overheads %

To Collection
Bill No. 008/ Page 5
Intercontinental Resort Hotel

RAK Properties
ITEM DESCRIPTION QUANTITY UNIT RATE AMOUNT AED

SUMMARY

SECTION D - DAYWORKS

Collection

Page No. Bill No. 008/ Page 1

Page No. Bill No. 008/ Page 2

Page No. Bill No. 008/ Page 3

Page No. Bill No. 008/ Page 4

Page No. Bill No. 008/ Page 5

To Grand Summary
Bill No. 008/ Page 6

You might also like