ULTRASONIC EXAMINATION Report No.: 77


CERTIFICATE Date: 02/01/2013 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp34 ML 34 TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


2 of 112
DATE: 1/2/2013 DATE: 1/2/2013 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 76
3 of 112

SHEET
CERTIFICATE Date: 31/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 35 ML 75

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

2500 - 2530 MM ✘ ✘

REMARKS / NOTE:

INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 35% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


4 of 112
DATE: 12/31/2012 DATE: 12/31/2012 DATE: DATE:
5 of 112
ULTRASONIC EXAMINATION Report No.: 75
CERTIFICATE Date: 31/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp35 ML 77 CO

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


6 of 112
DATE: 12/31/2012 DATE: 12/31/2012 DATE: DATE:
7 of 112
ULTRASONIC EXAMINATION Report No.: 74
CERTIFICATE Date: 29/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp31 ML 19 TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


8 of 112
DATE: 12/23/2012 DATE: 12/23/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 73 9 of 112

SHEET
CERTIFICATE Date: 25/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING OF 32 X 12,7mm CS HOT BENDS ON COMPRESSION AND TENSION AREA

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0° 60
WAVE TYPE LONGITUDINAL Compression
PULS AREA DIMENSIONS 100mm 8x9
GAIN SETTING 53db 57db
SCALE 50 50 mm
FREQUENCY 4Mhz 4 Mhz
SERIAL No. 120346104 821627 4 Mhz
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING HOT BEND CH 5- 59287

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

NO LAMINATION FOUND AND NO SIGNIFIGANT DEFECTS,HELICAL JOINTS ON HOT BENDS FOUND ACCEPTABLE

Bonatti Inspector Bonatti QA/QC PUIL ISG

DATE: 12/25/2012 DATE: 12/25/2012 DATE: DATE:


ULTRASONIC EXAMINATION Report No.: 72
10 of 112

SHEET
CERTIFICATE Date: 25/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING OF 32 X 12,7mm CS HOT BENDS ON COMPRESSION AND TENSION AREA

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0° 60
WAVE TYPE LONGITUDINAL Compression
PULS AREA DIMENSIONS 100mm 8x9
GAIN SETTING 53db 57db
SCALE 50 50 mm
FREQUENCY 4Mhz 4 Mhz
SERIAL No. 120346104 821627 4 Mhz
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING HOT BEND CH 6- 44494

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

NO LAMINATION FOUND AND NO SIGNIFIGANT DEFECTS,HELICAL JOINTS ON HOT BENDS FOUND ACCEPTABLE

Bonatti Inspector Bonatti QA/QC PUIL ISG


11 of 112
DATE: 12/25/2012 DATE: 12/25/2012 DATE: DATE:
12 of 112
Report No.:
ULTRASONIC EXAMINATION
SHEET
CERTIFICATE Date:

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0° 60
WAVE TYPE LONGITUDINAL Compression
PULS AREA DIMENSIONS 100mm 8x9
GAIN SETTING 53db 57db
SCALE 50 50 mm
FREQUENCY 4Mhz 4 Mhz
SERIAL No. 120346104 821627 4 Mhz
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT

LENGTH HIGH DEPTH DEPTH LINEAR ROUNDED ACCEPT REJECT

PUIL

DATE: DATE: DATE: DATE:


ULTRASONIC EXAMINATION Report No.: 70
13 of 112

SHEET
CERTIFICATE Date: 25/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING OF 32 X 12,7mm CS HOT BENDS ON COMPRESSION AND TENSION AREA

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0° 60
WAVE TYPE LONGITUDINAL Compression
PULS AREA DIMENSIONS 100mm 8x9
GAIN SETTING 53db 57db
SCALE 50 50 mm
FREQUENCY 4Mhz 4 Mhz
SERIAL No. 120346104 821627 4 Mhz
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING HOT BEND CH 4 - 60365

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

NO LAMINATION FOUND AND NO SIGNIFIGANT DEFECTS,HELICAL JOINTS ON HOT BENDS FOUND ACCEPTABLE

Bonatti Inspector Bonatti QA/QC PUIL ISG


14 of 112
DATE: 12/25/2012 DATE: 12/25/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 69
15 of 112

SHEET
CERTIFICATE Date: 25/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING OF 32 X 12,7mm CS HOT BENDS ON COMPRESSION AND TENSION AREA

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0° 60
WAVE TYPE LONGITUDINAL Compression
PULS AREA DIMENSIONS 100mm 8x9
GAIN SETTING 53db 57db
SCALE 50 50 mm
FREQUENCY 4Mhz 4 Mhz
SERIAL No. 120346104 821627 4 Mhz
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING HOT BEND CH 4 - 60320

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

NO LAMINATION FOUND AND NO SIGNIFIGANT DEFECTS,HELICAL JOINTS ON HOT BENDS FOUND ACCEPTABLE

Bonatti Inspector Bonatti QA/QC PUIL ISG


16 of 112
DATE: 12/25/2012 DATE: 12/25/2012 DATE: DATE:
17 of 112
ULTRASONIC EXAMINATION Report No.: 68
CERTIFICATE Date: 24/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp29 ML 200 TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


18 of 112
DATE: 12/24/2012 DATE: 12/24/2012 DATE: DATE:
19 of 112
ULTRASONIC EXAMINATION Report No.: 67
CERTIFICATE Date: 23/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp24 ML 50 TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


20 of 112
DATE: 12/23/2012 DATE: 12/23/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 66
21 of 112

SHEET
CERTIFICATE Date: 26/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70° 60°
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 33 ML 02 RX

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1000 MM 12.06 ✘

REMARKS / NOTE:

NO SIGNIFIGANT DEFECT NOTED

Bonatti Inspector Bonatti QA/QC PUIL ISG


22 of 112
DATE: 12/26/2012 DATE: 12/26/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 65
23 of 112

SHEET
CERTIFICATE Date: 23/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 44 ML 49

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

650-750 MM 100MM 10,20 ✘ ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


24 of 112
DATE: 23/12/2012 DATE: 23/12/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 64
25 of 112

SHEET
CERTIFICATE Date: 23/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 44 ML 34

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

00-720 MM 720MM 10,00 ✘ ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


26 of 112
DATE: 23/12/2012 DATE: 23/12/2012 DATE: DATE:
27 of 112
ULTRASONIC EXAMINATION Report No.: 63
CERTIFICATE Date: 20/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp22 ML81A CO TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


28 of 112
DATE: 12/20/2012 DATE: 12/20/2012 DATE: DATE:
29 of 112
ULTRASONIC EXAMINATION Report No.: 62
CERTIFICATE Date: 20/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp22 ML81CO TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


30 of 112
DATE: 12/20/2012 DATE: 12/20/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 61
31 of 112

SHEET
CERTIFICATE Date: 25/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm LINE IS CPF TO REG

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 31 ML 07

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

2400-2520mm 120MM 8.7 ✘ ✘

REMARKS / NOTE:

(LB) INDUCATION WITH ECHO( 80%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


32 of 112
DATE: 11/25/2012 DATE: 11/25/2012 DATE: DATE:
33 of 112
ULTRASONIC EXAMINATION Report No.: 60
CERTIFICATE Date: 18/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp21 ML 44CO TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


34 of 112
DATE: 12/12/2012 DATE: 12/12/2012 DATE: DATE:
35 of 112
ULTRASONIC EXAMINATION Report No.: 59
CERTIFICATE Date: 18/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp22 ML 44CO TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


36 of 112
DATE: 12/12/2012 DATE: 12/12/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 58
37 of 112

SHEET
CERTIFICATE Date: 15/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 50 ML29

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

2210-2240 MM 30MM 9,90MM ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO( 50%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


38 of 112
DATE: 12/15/2012 DATE: 12/15/2012 DATE: DATE:
39 of 112
ULTRASONIC EXAMINATION Report No.: 57
CERTIFICATE Date: 13/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp19 ML 03CO TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


40 of 112
DATE: 12/13/2012 DATE: 12/13/2012 DATE: DATE:
41 of 112
ULTRASONIC EXAMINATION Report No.: 56
CERTIFICATE Date: 13/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp19 ML 04CO TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


42 of 112
DATE: 12/13/2012 DATE: 12/13/2012 DATE: DATE:
43 of 112
ULTRASONIC EXAMINATION Report No.: 55
CERTIFICATE Date: 12/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp20 ML 45CO TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


44 of 112
DATE: 12/12/2012 DATE: 12/12/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 54
45 of 112

SHEET
CERTIFICATE Date: 11/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 47 ML15

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

190-260 MM 70MM 9,60MM ✘

300-400MM 100MM 9,40MM ✘

620-670MM 50MM 9,40MM ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


46 of 112
DATE: 12/11/2012 DATE: 12/11/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 53
47 of 112

SHEET
CERTIFICATE Date: 11/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 46 ML17

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

350-500 MM 150MM 9,60MM ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


48 of 112
DATE: 12/11/2012 DATE: 12/11/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 52
49 of 112

SHEET
CERTIFICATE Date: 11/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 48 ML56

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

190-250 MM 60MM 9,40MM ✘ ✘

450-510MM 60MM 9,40MM ✘ ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


50 of 112
DATE: 12/11/2012 DATE: 12/11/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 51
51 of 112

SHEET
CERTIFICATE Date: 11/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 46 ML69

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

750-800 MM 50MM 12,40MM ✘

REMARKS / NOTE:

DEPTH MORE THAN THIKNESS 1,30 MM

Bonatti Inspector Bonatti QA/QC PUIL ISG


52 of 112
DATE: 12/11/2012 DATE: 12/11/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 50
53 of 112

SHEET
CERTIFICATE Date: 11/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 46 ML57

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1960-2040 MM 80MM 9,40MM ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


54 of 112
DATE: 12/11/2012 DATE: 12/11/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 49
55 of 112

SHEET
CERTIFICATE Date: 11/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 47 ML13

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

290-320 MM 30MM 8,90 MM ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


56 of 112
DATE: 12/11/2012 DATE: 12/11/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 48
57 of 112

SHEET
CERTIFICATE Date: 11/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 47 ML06

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

80-100 MM 20MM 9,10 MM ✘

410-450MM 40MM 8,70 MM ✘

510-590MM 80MM 9,10 MM ✘

1050-1110MM 60MM 9,20 MM ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


58 of 112
DATE: 12/11/2012 DATE: 12/11/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 47
59 of 112

SHEET
CERTIFICATE Date: 11/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 46 ML80

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

360-420 MM 60MM 8,90 MM ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


60 of 112
DATE: 12/11/2012 DATE: 12/11/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 46
61 of 112

SHEET
CERTIFICATE Date: 11/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 46 ML75

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

30-100 MM 70MM 8,70 MM ✘

200-300MM 100MM 8,70 MM ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


62 of 112
DATE: 12/11/2012 DATE: 12/11/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 21
63 of 112

SHEET
CERTIFICATE Date: 08/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 62db 62db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 19ML 41

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

170 10.4 ✘ ✘

REMARKS / NOTE:

ECHO( 50%-70%) - REQUESTED BY RT REPORT No.181 PL

Bonatti Inspector Bonatti QA/QC PUIL ISG


CHAUCHE Zohelr
LEVEL II ASNT
PT RT MT UT
NDT INSPECTOR
64 of 112
DATE: 11/9/2012 DATE: DATE: DATE:
65 of 112
Report No.: 22
ULTRASONIC EXAMINATION
SHEET
CERTIFICATE Date: 15/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp16 ML 44C

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


66 of 112
DATE: 11/15/2012 DATE: 11/15/2012 DATE: DATE:
67 of 112
Report No.: 23
ULTRASONIC EXAMINATION
SHEET
CERTIFICATE Date: 17/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp16 ML 72C

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


68 of 112
DATE: 11/17/2012 DATE: 11/17/2012 DATE: DATE:
69 of 112
Report No.: 24
ULTRASONIC EXAMINATION
CERTIFICATE Date: 19/11/2012 SHEET 1/1

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp17 ML 57 C

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


70 of 112
DATE: 11/19/2012 DATE: 11/19/2012 DATE: DATE:
71 of 112
Report No.: 25
ULTRASONIC EXAMINATION
CERTIFICATE Date: 20/11/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp18 ML 68 C

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


72 of 112
DATE: 11/20/2012 DATE: 11/20/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 26
73 of 112

SHEET
CERTIFICATE Date: 24/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 62db 62db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 18ML 49

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

2110mm 4MM 10.1 ✘ ✘

2370mm 5MM 9.6 ✘ ✘

REMARKS / NOTE:

ECHO( 50%-80%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


74 of 112
DATE: 11/24/2012 DATE: DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 27
75 of 112

SHEET
CERTIFICATE Date: 25/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 40 ML 02

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1000-1050mm 50MM 7.9 ✘ ✘

REMARKS / NOTE:

(LB) INDUCATION WITH ECHO( 80%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


76 of 112
DATE: 11/25/2012 DATE: 11/25/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 28
77 of 112

SHEET
CERTIFICATE Date: 25/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 40 ML 06

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1240-1260 mm 20MM 9.7 ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO( 70%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


78 of 112
DATE: 11/25/2012 DATE: 11/25/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 29
79 of 112

SHEET
CERTIFICATE Date: 25/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 40 ML 15

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1280 -1310 MM 30MM 11.14 ✘ ✘

REMARKS / NOTE:

CRACK INDICATION WITH ECHO +100% DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


80 of 112
DATE: 11/25/2012 DATE: 11/25/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 30
81 of 112

SHEET
CERTIFICATE Date: 25/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 40 ML 78

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1170-1220 MM 50MM 9.5 ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO( 90%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


82 of 112
DATE: 11/25/2012 DATE: 11/25/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 31
83 of 112

SHEET
CERTIFICATE Date: 25/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 41 ML 06

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1270-1280 MM 10MM 9.9 ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO( 70%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


84 of 112
DATE: 11/25/2012 DATE: 11/25/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 32
85 of 112

SHEET
CERTIFICATE Date: 25/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 43 ML 11

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1380-1390 MM 10MM 10.5 ✘ ✘

REMARKS / NOTE:

(LS) INDICATION WITH ECHO(< 50%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


86 of 112
DATE: 11/25/2012 DATE: 11/25/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 33
87 of 112

SHEET
CERTIFICATE Date: 26/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57db 57db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 43 ML 15

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1210-1220 mm 10MM 8.8 ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO(< 50%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


88 of 112
DATE: 11/26/2012 DATE: 11/26/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 34
89 of 112

SHEET
CERTIFICATE Date: 27/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 43 ML 37

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1320 - 1340 mm 20MM 5-9,2 mm ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO( 80%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


90 of 112
DATE: 11/27/2012 DATE: 11/27/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 35
91 of 112

SHEET
CERTIFICATE Date: 28/11/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 21 ML 63RR

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1000 -1060 MM 60MM 9,5 mm ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO( 60%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


92 of 112
DATE: 11/28/2012 DATE: 11/28/2012 DATE: DATE:
93 of 112
ULTRASONIC EXAMINATION Report No.: 36
CERTIFICATE Date: 02/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp15 ML 33 TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


94 of 112
DATE: 12/2/2012 DATE: 12/2/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 37
95 of 112

SHEET
CERTIFICATE Date: 03/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 33 ML55

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

2340-2370 MM 30MM 8,55 mm ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO( 60%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


96 of 112
DATE: 12/3/2012 DATE: 12/3/2012 DATE: DATE:
97 of 112
ULTRASONIC EXAMINATION Report No.: 38
CERTIFICATE Date: 05/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp18 ML 20CO TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


98 of 112
DATE: 12/5/2012 DATE: 12/5/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 39
99 of 112

SHEET
CERTIFICATE Date: 06/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 35 ML75

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

2500 -2530 mm 30MM 12,1mm ✘ ✘

REMARKS / NOTE:

DEPTH MORE THAN THIKNESS 1,0MM

Bonatti Inspector Bonatti QA/QC PUIL ISG


100 of 112
DATE: 12/6/2012 DATE: 12/6/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 40
101 of 112

SHEET
CERTIFICATE Date: 06/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 44 ML55

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

420-750 MM 330MM 8,34 MM ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO LESS THAN ( 50%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


102 of 112
DATE: 12/6/2012 DATE: 12/6/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 41
103 of 112

SHEET
CERTIFICATE Date: 06/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 45 ML03

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1010-1020 MM 10MM 8,25 MM ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO LESS THAN ( 50%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


104 of 112
DATE: 12/6/2012 DATE: 12/6/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 42
105 of 112

SHEET
CERTIFICATE Date: 06/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 45 ML48

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

1800 -1850MM 50MM 12,1 MM ✘ ✘

REMARKS / NOTE:

DEPTH MORE THAN THIKNESS 1,0 MM

Bonatti Inspector Bonatti QA/QC PUIL ISG


106 of 112
DATE: 12/6/2012 DATE: 12/6/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 43
107 of 112

SHEET
CERTIFICATE Date: 06/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 44 ML48

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

50- 60MM 10MM 9,6 MM ✘ ✘

REMARKS / NOTE:

(LB) INDICATION WITH ECHO ( 70%) OF DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


108 of 112
DATE: 12/6/2012 DATE: 12/6/2012 DATE: DATE:
109 of 112
ULTRASONIC EXAMINATION Report No.: 44
CERTIFICATE Date: 10/12/2012 SHEET

Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION UT SCANNING FOR DETECTION OF LAMINATION INDICATIONS ON CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES NO ✘ YES NO ✘ YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus
TYPE EPOCH 600 PF4R-10
ANGLE BEAM 0°
WAVE TYPE LONGITUDINAL
PULS AREA DIMENSIONS 100mm
GAIN SETTING 53db
SCALE 50
FREQUENCY 4Mhz
SERIAL No. 120346104 821627
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp21 ML 63CO TI

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

REMARKS / NOTE:

no lamination indication found before beveling

Bonatti Inspector Bonatti QA/QC PUIL ISG


110 of 112
DATE: 12/10/2012 DATE: 12/10/2012 DATE: DATE:
ULTRASONIC EXAMINATION Report No.: 45
111 of 112

SHEET
CERTIFICATE Date: 11/12/2012
Project
IN SALAH GAS SOUT FIELDS Bonatti Job
DEVELOPMENTS PROJECT DZ 3001

ITEM DESCRIPTION welding examination confirmation UT CS 32X11,1mm

APPLICABLE CODE APPLICABLE PROCEDURE APPLICABLE SPECIFICATION / ACCEPTANCE CRITERIA

UUOO-P-QQPF-000-3515 Rev A API 1104

EXAMINATION / SURFACE CONDITION:


AS WELDED PWHT CAPPING CLEANNING
YES ✘ NO YES NO YES ✘ NO YES ✘ NO

EQUIPMENT
UT SET PROBE No 1 PROBE No 2 PROBE No 3 PROBE No 4
TRADE MARK olympus olympus olympus
TYPE EPOCH 600
ANGLE BEAM 70 60
WAVE TYPE Compression Compression
PULS AREA DIMENSIONS 8x9 8x9
GAIN SETTING 57,8db 57,8db
SCALE 50 mm 50 mm
FREQUENCY 4 Mhz 4 Mhz
SERIAL No. 120346104 821604 821198
REFERENCE BLOCK same materiel CALIBRATION BLOCK: V1-V2 COUPLANT: IPRAGEL
SCANNING DRAFT Kp 46 ML76

EXAMINATION RESULT
DIMENSION TYPE ASSESSMENT
LOCATION
(FROM 12 O'CLOCK)
LENGTH HIGH DEPTH LINEAR ROUNDED N/A ACCEPT REJECT

280-350 MM 70MM 8,70 MM ✘

REMARKS / NOTE:

ALLIGNED ROUND INDICATION FOUND WITH ECHO AMPLITUDE LESS THAN 45% OF THE DAC

Bonatti Inspector Bonatti QA/QC PUIL ISG


112 of 112