You are on page 1of 2

COLUMN DESIGN/ANALYSIS SOFTWARE

(Based on the NSCP 2015 Code)


Designer: GRSILOT Checked by: GRS
Date: Jan-19 Date: Jan-19

Project Name: 2STOREY COMMERCIAL BLDG.


Column I.D. : Interior Ground Columns(C-4)

INPUT:
Column Shape: Reinforcing Bars Data:
Main bar diameter = 25 mm
Dimensions: Number of bars along face X = 5 bars
Width, bx = 500 mm Number of bars along face Y = 4 bars
Breadth, by = 500 mm Total number of bars = 14 bars
Concrete cover = 40 mm Steel Ratio, rg = 2.749%

Materials: Transverse Rebars:


Concrete, fc' = 20.7 MPa Tie diameter = 10 mm
Steel rebar, fy = 230 MPa Max. Demand/Capacity Ratio = 0.962 (Ok!)

Factored forces: y
Pu Mux Muy Muy
(kN) (kN-m (kN-m)
Case 1 1207.857 43.35 -120.023 by x
Case 2 580.336 151.768 245.9
Case 3 614.63 -120.12 -213.429 bx
Mux
Case 4 580.336 151.768 245.9
Case 5 614.63 -120.12 -213.429

OUTPUT:
Pu fPn D/C
Remarks
(kN) (kN) Ratio
Case 1 1207.857 2058.4 0.587 (Ok!) 1208 43.35 120.023
Case 2 580.336 603.3 0.962 (Ok!) 580.3 151.8 245.9
Case 3 614.63 753.8 0.815 (Ok!) 614.6 120.1 213.429
Case 4 580.336 603.3 0.962 (Ok!) 580.3 151.8 245.9
Case 5 614.63 753.8 0.815 (Ok!) 614.6 120.1 213.429
INTERACTION DIAGRAM(s):
COLUMN INTERACTION DIAGRAM (Mx , Mr)
7000

6000

5000
fPnx , fPnr

4000

3000

2000

1
1000
3
5 2
4
0
0 100 200 300 400 500 600
-1000
fMnx , fMnr

Note: Disregard Interaction Diagram, My below for circular columns.

COLUMN INTERACTION DIAGRAM (My)


7000

6000

5000

4000
fPny

3000

2000

1
1000
3
5 2
4

0
0 50 100 150 200 250 300 350 400 450 500

fMny

You might also like