Pump Net Positive Suction Head

(Available)
Flow Rate 360 USGPM Input Cells
Viscosity 0.769 cP
Vapor Pressure 200 psia
Specific Gravity 0.485
Pump Efficency 62%
Absolute Total Suction Calculation of Hydraulic
Absolute Total Suction Pressure Pressure Power
Hyd hp
Inlet Pressure 200 psia Outlet Pressure 220 psia
Elevation (Static 20 f Elevation (Static 74 f Calculation of Actual Horse
Head) 4.2 psi Head) 15.5 psi Power
Line Friction 0.7 psi Line Friction 16.2 psi Brake hp
Misc psi Misc 13 psi
Total 203.5 psia Total 264.7 psia
188.8 psig 250.0 psig

Differential
Pressure 61.2 psi Calculation of NPSHA
Differential Head 292 f Inlet Pressure 200 psia

Safety Factor 10 % 20 f
Elevation (Static
Required Head)
321 f 4.2 psi
Differential Head

Line Friction 0.7 psi


Maximum Misc 0 psi
204.2 psi
Suction Pressure Fluid Vapor 200 psia
Pressure
Shut Off Head 1337.2 f 3.5 psi
NPSHA 16.7 f
Calculation of Hydraulic
Power
14.1 hp

Calculation of Actual Horse


Power
22.8 bhp