You are on page 1of 2

OPW 1500 Automatic T a n k

Gauging System
High quality. Low cost. That’s what you get with the OPW 1500
Automatic Tank Gauging System.
The 1500 gives you everything you need for enhanced compliance.
The Segmented Leak Detection feature allows you to perform in-tank
leak testing continuously without having to shut down your tanks.
SmartTalk™, OPW’s enhanced fuel management software combines
tank and compliance information for accurate management of
multiple fueling sites from your central office.

Special Features
• Backlit LCD display
• Alphanumeric keypad
• Continuous monitoring for up to 4 tanks
• Console diagnostic codes
• Rolling 250-event troubleshooting history

Regulatory Compliance
• Segmented Leak Testing (SLD) for 24-hour sites
Reporting Capabilities
• Tanks, sumps, wells, lines
• S
 hift reports can be programmed to be stored automatically three
• Programmable leak tests (daily, weekly, monthly, continuously times daily. The information can be displayed via the on-site
or on demand)
computer, off-site computer or printed on the system printer.
• Selectable leak rates 0.2 gph (0.76 lph), 0.1 gph (0.38 lph)
• On-demand reports: Inventory Status, Shift Report, Delivery Status,
• Automatic notification of compliance deadlines
Alarm Status, Sensor Status, Generator Usage History, Event History,
Leak Test History
Inventory Management
• Fuel height and volume Self-monitoring Capabilities
• Shift reports • Designed to minimize service time and costs
• Automatic fuel delivery reports • Rolling 250-event detailed history aids in trouble shooting

Connectivity Automated Convenience Intuitive


SmartTalk software connects fuel Segmented Leak Detection (SLD) Automatic reports: Delivery, Diagnostic codes displayed on
tanks with back-office computers, software provides continuous Inventory, Alarm Status, Leak Test the console tell service technicians
providing enhanced inventory testing so 24-hour operations never history and more. what is wrong
and compliance management for have to shut down for 0.2 gph
multiple sites compliance testing

L E A D I N G   T H E   W A Y I N T A N K G A U G E I N N O V A T I O N
L ow C os t T a n k L e v e l M o n i t o r i n g and Leak Sensing
• Temperature: ± 0.50 F (± 0.30 C)
Comprehensive Programmable Alarms
• 0.2 gph (0.76 lph) Static Leak Test: 99% Pd, 1% Pfa
• High Product
• 0.2 gph (0.76 lph) Continuous Leak Test: 99.1% Pd, 0.9% Pfa
• Low Product
• 0.1 gph (0.381 lph) Static Leak Test: 99% Pd, 1% Pfa
• High Water
• E
 PA Leak Test Certified: 15,000-gallon tank (56,781 liters) for static tests
• Theft
35,000-gallon tank with SLD (132,475 liters) for single or manifold tanks
• Leak Test Failed
• Leak Test Required
• Modern auto-dial feature sends alarms to remote
Probe Specifications
computer automatically • Type: Magnetostrictive/Float

• Material: Stainless-steel shaft

Stand-by Generator • Location: Hazardous, Class 1, Division 1, Group D

• Programmable option available in standard software • Temperature: 5 RTDs


• G
 enerator usage and history reports, including start time, • Temperature Range: -400 F to 1580 (-400 C to 700 C)
stop time, and fuel usage provided after generator operation • Data Cable: <
_ 250’ (76 m) Use Belden 8760
• S
 ystem handles a mix of standard and stand-by generator tanks 250’ - 1000’ (76 m - 304 m) Use Belden 9182
at the same time

Leak Sensor Specifications


Serial Communications • Number of Sensors: Up to 8
• Local and modem ports standard
• Sensor Types: OPW discriminating and non-discriminating sensors

• Discriminating Dispenser Pan: Q0003-001


Console Specifications • Discriminating STP Sump: Q0003-002
• Dimensions: 13”W, 11.25”H, 6”D (33 x 28.6 x 15.25 cm)
• Discriminating Interstitial: Q0003-003
• Weight: 15 lbs.
• D
 iscriminating Monitoring Well: Q0003-104 10’ (3 m)
• Operating Temperature: 320 to 1040 F (00 to 400 C) Q0003-154 15’ (4.5 m)
Q0003-204 20’ (6 m)
• Humidity: 90% non-condensing
• Wet Interstitial: Q0003-005
• Typical Mounting Location: Protected, non-hazardous area
• Liquid-only Interstitial: Q0003-006
• Power
 Requirements: 120 VAC ± 10%, 60 Hz.
15-amp dedicated circuit • Liquid Float: Q0003-009

• Listings and Approvals: CSA, ETL

• System Relay: 10 amp, 250 VAC contacts I

• RS-232 (optional): 2 ports (modem and local)


L I STED
®

• Relays: 1 standard, 4 optional

TLM Specifications
• Number of Tanks: Up to 4

• Probe Inputs: Intrinsically-safe magnetostrictive

• Probe Power Supply: 26 VDC

• Level Precision: ± 0.0005” (0.0013 cm)

• Level Accuracy: ± 0.04% full scale

6900 SANTA FE DRIVE • HODGKINS, IL USA 60525 • www.opwfms.com • 708-485-4200 • (fax) 708-485-4630

NOTE: All information subject to engineering and/or other changes. All trade names are copyrighted. Patents Pending. ©2009 OPW Fuel Management Systems.
©2009 Delaware Capital Formation, Inc. All Rights Reserved. DOVER and the DOVER logo are registered trademarks of Delaware Capital Formation, Inc., a wholly-owned subsidiary of Dover Corporation. 1500AutoTnkSys • 9/09 0M

You might also like