FORMULARIO

INFORME DE ENSAYOS MET

EMPRESA MINERA LOS QUENUALES S.A


Laboratorio Químico Iscaycruz
Telef : 3151800 Anexos 6110-6111

CÓDIGO: MET - ISC Nº 003/06/2012


CLIENTE : Laboratorio Metalúrgico -Iscaycruz

FECHA DE RECEPCION : 3-jun-2012 CANTIDAD DE MUESTRAS :

LUGAR DE RECEPCION : Laboratorio Iscaycruz - Area preparación de muestras CARACTERISTICAS Y CONDICIONES :

FECHA DE REPORTE : 6-jun-2012

TIPO DE MUESTRA : HORA DE REPORTE :

Nº Muestras Codigo Descripción % Cu % Pb % Zn Ag (oz/Tm) % Fe % Insolubles


18 1208 LM CC CL3 CU P-22 18.21 0.44 6.52 11.85 31.45 15.64
7 1208 LM RLV CL3 CU P-22 6.96 0.19 10.74 4.97 36.26
2 1208 LM RLV CL2 CU P-22 2.32 0.09 9.10 1.85 43.15
17 1208 LM CC CL SCV CU-P22 2.70 0.16 10.68 2.07 35.86
1 1208 LM RLV CL SCV P22 1.26 0.08 8.47 1.04 29.50
16 1208 LM CC SCV CU P-22 0.37 0.12 15.21 0.28 33.51
19 1208 LM CC CL3 A ZN P-22 0.37 0.10 52.47 0.28 12.57 3.84
21 1208 LM CC CL3 B ZN P-22 0.37 0.10 52.10 0.33 12.31 5.08
6 1208 LM RLV CL3 ZN P-22 0.44 0.03 48.23 0.36 11.19
5 1208 LM RLV CL2 ZN P-22 0.47 0.03 43.87 0.38 12.41
22 1208 LM CC CL SCV ZN P-22 0.44 0.12 45.43 0.34 13.41
23 1208 LM CC SCV 1 ZN P-22 0.28 0.14 15.94 0.18 28.19
20 1208 LM CC SCV2 ZN P22 0.19 0.14 7.89 0.13 38.09
4 1208 LM RLV CL SCV ZN P-22 0.40 0.05 30.87 0.29 15.29
3 1208 LM RLV SCV ZN P-22 0.05 0.06 0.58 0.05 31.31
31 1208 LM CC CL2 CU P-23 15.89 0.23 3.96 12.70 17.77 33.92
14 1208 LM RLV CL2 CU P-23 12.58 0.14 8.34 7.86 24.26
30 1208 LM CC CL SCV CU P-23 1.88 0.24 9.87 1.67 21.91
8 1208 LM RLV CL SCV CU P-23 0.29 0.12 6.23 0.27 18.67
29 1208 LM CC CL2 SCV CU P-23 24.50 0.27 2.87 21.35 32.27 14.86
10 1208 LM RLV CL2 SCV CU P-23 7.91 0.69 11.49 6.26 24.60
9 1208 LM RLV CL1 SCV P-23 2.79 0.18 8.18 2.13 32.40
25 1208 LM CC CL3 A ZN P-23 0.90 0.13 50.25 0.79 13.98 5.12
1 de 6
26 1208 LM CC CL3 B ZN P-23 0.88 0.12 49.92 0.79 14.04 7.54
13 1208 LM RLV CL3 ZN P-23 0.70 0.10 45.85 0.58 16.22
15 1208 LM RLV CL2 ZN P-23 0.45 0.11 33.75 0.36 22.64
27 1208 LM CC CL SCV ZN P-23 0.38 0.12 33.17 0.25 25.30
12 1208 LM RLV CL SCV ZN P-23 0.24 0.09 20.52 0.17 25.81
28 1208 LM CC SCV1 ZN P-23 0.18 0.15 1.26 0.09 39.39
24 1208 LM CC SCV ZN P-23 0.13 0.14 0.95 0.04 35.78
11 1208 LM RLV SCV ZN P-23 0.04 0.11 0.18 0.02 35.06

2 de 6

Analista:
Supervisor:

ESQUEMA Y METODO : Digestión Multiácida ( HCl + HNO3 + HClO4 ).

Las contramuestras en pulpa en m-140 tendrá un periodo o tiempo de permanencia en el almacen de contramuestras del Laboratorio
Iscaycruz durante 1 mes , en este periodo el cliente podrá retirarlo en el momento que crea oportuno, caso contrario serán desechadas.

…………………………………..
cc. Red del Laboratorio Ing.
cc. Archivo. Jefe Laboratorio Químico

3 de 6
FORMULARIO CÓDIGO FI-LBQ-044

REVISION 00
INFORME DE ENSAYOS MET
APROBADO 29.11.2011

31 Muestras
Muestras ensobradas

5:00 AM
% PbO % ZnO …… …. ….

4 de 6
5 de 6
…………………………………..

6 de 6