NW4000-1000 (-A optional for Aluminium vessels only)

Installation Package NW-4000 (S)VDR & VDR

V2.1 CONTENTS — Cabling, microphones and mechanical parts

NW-4001 Qty: 1 roll of 75 meters

75 meters (246 ft) WaveNet approved CAT5E


network cable
Ethernet installation cable with twisted-pair solid wires, particu-
larly suitable for permanent installation outside the control cabi-
net/ switch box. It has been specifically developed for Category 5
industrial Ethernet applications (up to 100 Mbps) and features a
very robust second outer sheath made from polyurethane (PUR).
With an outside diameter of 7.8 mm (0.307 in.), the cable has a
high level of mechanical capability and is ideal for leading
through standard threaded joints. Once within the NetWave VDR
units, the outer sheath is easily removed using a tearing wire,
leaving a secondary—inner—isolation layer. The braided shield-
ing is fixed to the cable-glands of the cabinets. Instructions are
accompanying the cable.

Flame-retardant in accordance with VDE 0482, Part 265-2-1 / IEC


332-1. Free of substances, which would hinder coating with paint
or varnish in accordance with the central standard 57 650.
Halogen-free compound, HM 2 in accordance with VDE 0207

Construction for Marine use


IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1 or VDE0482 Part
265-2-1
> Halogen Free Properties 1
IEC 60754-1 and -2 or VDE0207

NW-4003 Qty: 1 roll of 150 meters*

150 meters NW-4003 (492 ft) RFA-HF* - Da-


taflamm microphone cable 1x4x0,34mm2 -
shielded, outer diameter 7,0mm

NW-4004 Qty: 1 roll of 30 meters*

30 meters NW-4004 (100 ft) RFA-HF Class ap-


proved* NMEA signal cable 1x2x0.5mm2—
shielded, outer diameter 6,5 mm

NetWave NW4000-1000 Pre-Installation Package Contents V2.1 July 2007 Page 1


* Class Approval from: ABS BV CCS DNV GL KRS LRS RMRS NK RINA and TC
NW-4006 Qty: 1 roll of 15
meters (50 ft)* 1

and

NW-4007 Qty: 1 roll of 15


meters (50 ft)* 1

Class Approved* Screened Power Supply Cable


LKAM-HF / MPRXCX

NW-4006 2/3 x2.5mm2 for 24 VDC to PSU


NW-4007 3x1,5mm2 for 85-264 VAC to PSU

IEC 60092-353, design


1. Conductor
- stranded copper conductor IEC 60228, class 2
2. Insulation
- XLPE plastic IEC 60092-351
3. Screen
- drain wire of tinned copper 1,5mm2 (in all sizes)
- aluminium polyester tape, IEC 60092-350
coverage 100%
4. Sheath
- grey polyolefine plastic, SHF1 IEC 60092-359

Application: For fixed installation in all areas and on open


deck in ships. If the cable is exposed to direct sun light
protective covering or cable with black outer sheath is
recommended.

Main characteristics

Rated voltage 0,6/1kV (1,2kV)


Maximum conductor temperature + 90 °C
Flame-retardant IEC 60332-1-2 -test for single insulated
wire and cable. IEC 60332-3-22 -test for bunched wires
and cables, category A
Halogen-free IEC 60754 series
Smoke emission IEC 61034 series

Outer diameter: 24V =10 mm, 240V= 8,5mm

Minimum recommended installation temperature -15 °C.


Lowest operation temperature -40 °C

* Class Approval from: ABS BV CCS DNV GL KRS LRS RMRS NK RINA and TC

NetWave NW4000-1000 Pre-Installation Package Contents V2.1 July 2007 Page 2


NW-4800-S Qty: 1 Capsule Deckmount Kit

The deckmount supports the capsule and is


(optionally) fitted on the welding plate NW4000-
768/9 (supplied) by means of the 5 bolts (M12 x
30 A4) provided, but may also be fitted directly
onto the deck.

Includes:

• 1 Deckmount A316 (H100)


• 1 Cable Gland M16x1,5*
• 1 Blind plate M16x1,5
• 5 M12x30 A4 stainless steel bolts
• 5 M12 Nord-Lock rings A4
• 5 Insulation sleeves
1
• 1 Insulation plate NBR
*Cable gland H101.1710.43 cable OD10,5mm

NW-4000-768 Mild steel Welding Plate (1)

This (uncoated) mild steel plate may be wel-


ded to the upper deck. Optionally this plate al-
lows the network cable to be fed through from
the bottom, rather than to be fed into the HSS
capsule deckmount horizontally. If so, cable
feed through is sealed with Lloyds approved
primer and sealant (supplied).

Aluminium version available as NW-4000-769


1
STANDARD SUPPLY

Optional, order ‘-A’ package


NW-4000-769 Aluminium Welding Plate (1)

(optional, ‘A’ as suffix to order-code for the pre-


installation package: NW-4000-1000A

NetWave NW4000-1000 Pre-Installation Package Contents V2.1 July 2007 Page 3


NW-4422 Qty: 6 Microphones

Microphone (internal/external) for bulkhead or


flush-mounting, incl, cable gland (for cable w.
OD 7,5mm) & O-ring set.

The microphone assembly may be changed in


the field to accommodate (IP67) protection
against water-ingress and moist. Furthermore,
by changing the assembly order, the microp-
hone may be bulkhead mounted or be ‘flush-
mounted’ into a panel.

Includes screws for metal and wood.

Microphone serial number: 1

Microphone serial number: 2

Microphone serial number: 3

Microphone serial number: 4

Microphone serial number (external): 5

Microphone serial number (external): 6

Microphone serial number:

Microphone serial number:

NW-4422-800 Qty: 1 Microphone Locking Key

Stainless steel locking key to assemble the


microphones

NetWave NW4000-1000 Pre-Installation Package Contents V2.1 July 2007 Page 4


NW-4423 Qty: 1 Holesaw

HSS Bi Metal 60,3 mm Holesaw constructed of


hardened, heat and abrasion resisting high
speed steel teeth with a tough alloy body.
This drill is used to easily flush-mount the mi-
crophones, providing the exact diameter.
U4000.060.001 FHS60

NW-4424 Qty: 1 Arbor

This drill is used in conjunction with NW-4423


Holesaw. FAB U 4035.000.110 / F-HSA3

NW-4400-770 Qty: 1 Sikaflex* sealant

The sealant is used to close the thru-hole in the


deck when the cabling into the deckmount
NW4000-768 or NW4000-769 is inserted di-
rectly from the underlying deck.
* or equivalent 1

NetWave NW4000-1000 Pre-Installation Package Contents V2.1 July 2007 Page 5


NW-4017 Bridge Control Unit mounting
bracket w. drill & saw plan

This bracket is used to mount the BCU NW-


4010 or NW4016 into a bridge console or bulk-
head, panel, etc. Includes 8 screws.

NW-4210 Qty: 1 PSU Mounting bracket kit

The slotted mounting bracket accommodates


bulkhead mounting of the PSU. Includes 6
screws. (bracket dim. 350wx220hx19d)
1

NW-4410 Qty: 1 WIM Mounting bracket kit

This slotted mounting bracket accommodates


bulkhead mounting of the WIM. Includes 6
screws. (bracket dim. 270wx220hx19d)

NW4000-10
VDR Ships and Operators Instruction Manual

• Mounting of the HSS Capsule & deckmount


• Mounting the microphones & seals
• Mounting the Bridge Control Unit bracket
• Mounting the WIM and PSU brackets
• Cable types, routing and connections
is also included in this manual

NetWave NW4000-1000 Pre-Installation Package Contents V2.1 July 2007 Page 6


PACKED BY (Name)______________________________________

DATE (dd/mm/yy) _____/_______/______

Signature: _____________________________________________________________

Remarks:

NW PACKING NOTE number:

Vessel Name:

Transport:

Tracking ID:

NetWave NW4000-1000 Pre-Installation Package Contents V2.1 July 2007 Page 7


NetWave is committed to supply Class approved third-party materials where and when available

NetWave is committed to supply Class approved materials where available but expects the customer to confirm appropriate com-
pliance in conjunction with the specific vessel (and Class) for which the installation is performed.
Nothing in this document is intended to conclude a contract on behalf of NetWave Systems BV or make NetWave Systems
BV subject to any other legally binding commitments. All transactions are subject to the General Terms and Conditions of NetWave
Systems BV which are available upon request and may be downloaded from our website.

Lichtenauerlaan 110
3062ME Rotterdam
Netherlands
tel. +31 10 2045665
Fax +31 10 2045555
www.netwavesystems.com

NetWave NW4000-1000 Pre-Installation Package Contents V2.1 July 2007 Page 8