You are on page 1of 6

RNC in Pool Scenario Solutions

Lossless Relocation in L Country B Operator


Operator’s Concern: How to Relocate RNC with No Service Interruption

Relocate RNC to New DC Room in Lit

DC Room

La
New DC Room
Lit 302km

Relocation may cause longtime service interruption Traditional solutions also cause traffic break

Online Online Test Bed


Uninstall RNC Transport Install RNC

RNC101 RNC103 Temporary RNC

0.5 day 1 day 0.5 day Rehoming NodeBs to temporary RNC when online RNC relocating
Challenges of Traditional Solutions with Temporary RNC

Step1: Expansion Temporary RNC to Step2: Rehoming Nobes to temporary Step3: Rehoming Nobes back to
match the capacity with online RNC RNC when Online RNC relocating Online RNC

Temporary RNC Temporary RNC Temporary RNC

Expansion

Latvia Lithuania Latvia Lithuania Latvia Lithuania

Challenge 1 Challenge 2 Challenge 3


20+ boards Invalid Investment 30 days human resourse 2 Times Traffic break
Expand 20+ board on 2 times NodeB rehoming for 1 2 times traffic break for 1 RNC
temporary RNC (2016Q4 EOM) RNC relocation. 30 days human relocation. Affect user
only for relocation resource wasting. experience when rehoming.
RNC in Pool Realize High Efficiency and Lossless Relocation

RNC6910 RNC6910
RNC6910
IUR-P IUR-P
IUR-P

Step1: Deploy RNC in Pool Step2: Switch NodeBs to RNC6910. Step3: Switch NodeB Back to
between new RNC6910 in DC Relocate online RNC to DC room. online RNC.
room and online RNC

No Invalid Investment No NodeB Rehoming No Traffic Break


New RNC 6910 help relocation and One-Click switch service to RNC Service fast recovery when switch
also support product evolution 6910 with easy operation. NodeBs to each other.
RNC in Pool: Realize Lossless Relocation, and Build High Reliability Network

 Realize Lossless Relocation, Improve Relocation


Efficiency

DC Room New product evolution vs Invalid Investment


No Traffic Breakvs 2 Times Traffic Break
One-Click Switch vs 30 Days for one person

What’s More:
With RNC in Pool, we can also:
Construct High Reliability Network
-Remove single point failure risk of RNC, IU, IUB

Smooth RNC Evolution


- Cover the new sites especially high traffic sites
- Extend the lifetime of RNC6900
MANY THANKS