Professional Documents
Culture Documents
net/publication/224758307
CITATIONS READS
2 39
4 authors, including:
C. Pagani
INFN - Istituto Nazionale di Fisica Nucleare
196 PUBLICATIONS 3,454 CITATIONS
SEE PROFILE
Some of the authors of this publication are also working on these related projects:
All content following this page was uploaded by Giuseppe Maria Penco on 02 June 2014.
The first advantage of the formulation presented in We have used is a Niodium Laser (Yag laser) as the
eq. (2) is that the normalized solution is independent from heat source. The laser beam is driven in the cryostat
the energy transmitted to the sample, which is often not straightly on the test sample, as it is shown in Figure 1.
completely known, for example for reflection effects and
inhomogeneities in the laser spot shape. In addition the 2.2 Test bench on OFHC copper
analysis needs to know only a normalized temperature
To test the accuracy of the Laser Flash measurements
measurement, and no absolute measurements, so it is
we have performed the first tests on a well-known copper
enough that the temperature sensor has a linear response
sample (OFHC: Oxygen Free High Conductivity), whose
to the temperature variation.
thermal properties are known from literature. This test
Here we present an extension of the Laser Flash
bench is also useful because it allows the comparison
technique to the cryogenic environments that uses a
between the excellent thermal properties of OFHC and
standard temperature sensor in direct contact with the rear
the results obtained from the Pure Coat coating.
surface.
The thermocouples voltage signal during the transient,
First of all the fast variation of the temperature, due to
at 300 K and at 77 K is only a few microvolts, due to the
the very low specific heat and high thermal conductivity
high energy fraction reflected by the sample and to the
of the sample, implies that the sensor and the data
thermal capacitance of copper. The electromagnetic noise
acquisition system should be fast enough to resolve the
thermal transient without perturbations. For this purpose in the acquisition system is about 1µV and is comparable
the sensor needs to have a much lower thermal inertia to the signal, so it is critical to extract the sample exact
than the sample and it needs to be in close contact with thermal behaviour. To simplify the data analysis we have
used a train of laser shots (at the laser repetition rate) on
the sample itself to avoid any thermal resistance affecting
the results. According to these sensor requirements, we the sample and we have acquired the whole thermal
have chosen to measure the thermal transient with very transient induced by the series of laser shots. The thermal
small thermocouples Au (0.007% Fe) / Cromel P, that are transient of each single shot is then extracted and
very sensible at cryogenic temperature and have a very normalized to 1, using the pretrigger data and the flat
small thermal mass. At cryogenic temperatures it is region (stationary temperature) after the transient as
references. Data from all shots are then smoothed. The
necessary to induce small temperature variations to
remain in the approximation of constant thermal smoothed data need to be compared with the theoretical
diffusivity. The thermocouple voltage results in the function of the transient. Using this data analysis
microvolts range and, therefore, must be amplified. To procedure we get a final thermal transient (Fig. 2) with a
test the time resolution limit of the experimental setup a resolution of about 0.1 µV, starting with a thermoelectric
laser single shot has been sent on the thermocouple alone signal in which the noise is dominant.
at room temperature, and we measured a response time of
about 10 µs, that corresponds to the chosen amplifier 1
1232
Proceedings of the 2001 Particle Accelerator Conference, Chicago
0,6
D [cm2/s]
1.1
0,4
1.05
D(t%)/ D real
0,2
1
0
Low Hot Centre Effect 0 20 40 60 80 100
0.95 t%
Heavy Hot Centre Effect
Heavy Cold Centre Effect
0.9
Low Cold Centre Effect Figure 4 Values of thermal diffusivity calculated from
0 20 40 60 80
t%
100 eq. (2) using different percentages (t%) of the raise time.
Figure 3. Behaviour of the thermal diffusivity in presence The good data correlation and the constant trend suggests
of hot/cold centre effect for fractions of the raise time that the filter procedure reduces the perturbative effects.
In presence of a hot (or cold) centre effect the sample Other Pure Coat samples have been measured, after
heating results faster (or slower) than the ideal case and annealing in ultra-vacuum (10-7 mbar) to improve their
so the thermal diffusivity is overestimated (or thermal properties (Table 3).
underestimated) during the transient [7]. When the
systematic errors are identified, it is possible to fit the Table 3. Pure Coat annealed samples.
data and to extrapolate the value at time τ=0. The T [K] DExp [cm2/s]
experimental apparatus that we have used does not show 77 1.27 ± 0.07
any of the anomalies presented in Fig. 3, but probably a 7.0 86.1 ± 9.1
combination of both and in addition there may be a 5.5 112 ± 9.8
combination of several other second order effects (for 4.2 200 ± 18
example the irregular shape of the laser spot, the irregular
superposition between the laser spot and the sample, the The data analysis of measurements below 10 K is easier
deviation from the ideal adiabatic condition, and so on). because the low thermal capacity produce higher
For this reason it is useful to calculate the thermal temperature variation.
diffusivity from eq. (2) by using different percentage of
the raise time and then averaging the different values 5 CONCLUSION
obtained [7]. The plot of these results, shown in Fig. 4,
allows the identification of their confidence or indicates if We have demonstrated that the laser flash technique
some significant perturbation has occurred during the can be used at cryogenic temperatures to investigate
measurements. Table 1 summarizes the results on the thermal properties. Results on annealed sprayed copper
OFHC copper (Dexp is the experimental value and DTh the are interesting for proton cavities stiffening, having
value found in literature): thermal properties closed to the requirements.
1233