OD = 1985 mm 1.985 m
H= 9000 mm 9m
Splash zone Area [3.5 m to -1.00m] 46.14 m2
Elevation between [-1.00 m -to -4.50 m] 34.51 m2
2 Design Parameter
2.1 Cathodic protection criteria : -1.05 volt vs Ag/AgCl
2.2 Type of CP : Sacrificial anode
2.3 Design life time (L) : 25 years
2.4 Calculation allowance (SF) : 10%
2.5 Resistivity Sea Water (r) : 20 ohm.cm
CALCULATION
1 Area to be protected
Splash zone Area [3.5 m to -1.00m] 46.14 m2
Elevation between [-1.00 m -to -4.50 m] 34.51 m2
2 Current Requirement
Ic = Ac x ic x fc (Amp)
3.5 to -1m -1 to -4.5 m Total
Initial 0.34605 5.1765 5.52255
Mean 0.96894 2.4157 3.38464
Final 2.5377 3.451 5.9887
3 Weight of anode
*mean condition
W= Ic x L x 8760 305.035457 kgs * u and c refer to DNV RP B401 (2005) tabel 10-
uxc
4 Number of Anode (By Weight Calculation)
N= W/Wa 5.680362324 → 6 Anodes Anode Utilization Factor (u