Specifications Unit Description and Function Setting RS485 Slave Mode (Input Data Chart)
Only the basic unit model has the function set switch and the input terminal. If there is no input data after supplying the power, the basic unit displays ‘T’.
INTELLIGENT DISPLAY UNIT Model
Basic unit DS16- T
Expansion unit DS 16- E
D 22- T
D 22- E
D 40- T
D 40- E
D 60- T
D 60- E The DS16, D 22 models have them at the side, and the D 40, D 60 models have them at the rear. DS Series (7-segment) DA Series (16-segment)
DU Series High 2-bit
(unit) Low 4-bit
(RS485 Communication Input) Input method RS485 communication (Modbus protocol) ①E xpansion connector
Using for connecting units.
② Function set switches
D5 D4 D5 D4 D5 D4 D5 D4 D5 D4 D5 D4 D5 D4 D5 D4 D5 D4
D3 D2 D1 D0
Display color Red, green (selectable by model) L L L H H L H H L L L H H L H H X X

DS/DA-T Series Refer to ‘ Connection of units’. JP1


Power supply 12-24VDCᜡ J2

Allowable voltage range 90 to 110% of rated voltage J4


No unit L L L L
● DS16- T 0 G W ] 0 G W ]
J8
Current Red type Max. 20mA Max. 25mA Max. 55mA Max. 65mA
INSTRUCTION MANUAL consumption Green type Max. 15mA Max. 20mA Max. 40mA Max. 45mA
③ J1 J16
Factory default
1 H X 1 H X
Upper-Lower
[ OFF
L L L H
Character size W9×H16mm W11.2×H22.5mm W22.4×H40mm W33.6×H60mm ① S1
S2
5
※Functions are varied by JP1 setting (RS485 Master mode/RS485
4 Upper-Lower
L L H L
S3

Display character Displays 64 types of character and sign (0 to 9, A to Z, 27 signs, dot)


J1
② 3 Slave mode).
2 I 2 I + ON
J2
J4
2 Y Y
Max. connection 24 units ● RS485 Slave mode (JP1 (Open))
J8
J16
JP1 1
Noise immunity ±500V the square wave noise (pulse width: 1㎲) by the noise simulator Upper ON L L H H
No. Switch OFF( )/ON( ) Function 3 J Z 3 J Z :
Environ- Ambient temp. -10 to 55℃, storage: -25 to 65℃
● D 22- T 5ms 20ms
ment Ambient humi. 35 to 85%RH, storage: 35 to 85%RH S1 Comm. response time Lower ON L H L L
4 K -1 ° 4 K -1 ;
Right/Left cap: 1
Basic unit Right/Left cap: 1 - Upper-Lower
Accessory Connector: 1 ③ S2 Comm. speed L H L H
Thank you for choosing our Autonics products.
O

< flashes
S1

Expansion unit - Ribbon cable (50mm): 1 ① S2 N


5 5 L ( ₩ 5 L (
S3
J1
S3 selection (bps)
Please read the following safety considerations before use. Approval ᜢ J2
J4
O
N
4
3 H Upper
L H H L
> flashes
J8

Approx. 52g Approx. 58g Approx. 63g Approx. 110g 6 M ) (h) 6 M )


Safety Considerations
J16 2
Basic unit ② 1
※1 (approx.12g) (approx. 17g) (approx. 28g) (approx. 60g) Lower
Weight J1 L H H H
※Please observe all safety considerations for safe and proper product operation to avoid hazards. Approx. 77g Approx. 92g Approx. 63g Approx. 110g | flashes
JP1

Expansion unit Comm. address 7 N ' I 7 N '


(approx.12g)
※2
(approx. 17g)
※2
(approx. 28g) (approx. 60g) to
※Safety considerations are categorized as follows. selection
※1: The weight includes packaging. The weight in parenthesis is for unit only. J16 H L L L
Warning Failure to follow these instructions may result in serious injury or death. ● D 40- T 8 O " J 8 O " !
※2: The weight represents a pack of 3 units. The weight in parenthesis is for 1 unit only.
Caution Failure to follow these instructions may result in personal injury or product damage. ※Environment resistance is rated at no freezing or condensation. H L L H
9 P ^ K 9 P ^ @
※The symbols used on the product and instruction manual represent the following. ● RS485 communication specifications ③ ● RS485 Master mode (JP1 (Short))
symbol represents caution due to special circumstances in which hazards may occur. Mode Slave Master Mode Slave Master 1 No. Switch OFF( )/ON( ) Function H L H L
Comm. protocol Modbus RTU with 16-bit CRC Comm. distance Max. 800m ① 2
A Q . K A Q . #
Warning Connection type RS485 Comm. speed 4800, 9600, 19200, 38400bps 3
Manual
setting
Auto
setting Series setting H L H H
4 S1 $
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury Application Comm. response time 5ms, 20ms - method B R / N B R /
※1
Compliance with EIA RS485 5
or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, standard Start bit 1-bit (fixed)
railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) 31 units (address: 1 unit (address: Data bit 8-bit (fixed) S2 H H L L
Max. connection
S1
② Comm.speed C S ? O C S ? %
Failure to follow this instruction may result in fire, personal injury, or economic loss.
S2

01 to 32) 01(fixed)) Parity bit None (fixed) S3


J1
selection (bps)
2. Install on a device panel to use. J2 S3 H H L H
Failure to follow this instruction may result in fire. Comm. type Two-wire half duplex Stop bit 1-bit (fixed) J4
JP1
J8
J16 D T - T D T - &
3. Do not connect, repair, or inspect the unit while connected to a power source. CT6 CT4 MP5 MT4 TK/TX TM2 TM4 THD
Failure to follow this instruction may result in fire. H H H L
Series selection
4. Check 'Unit description and function setting' before wiring.
Failure to follow this instruction may result in fire. Dimensions (unit: mm)
※N: The number of units (manual setting)
E U _ X E U _ ★

5. Do not disassemble or modify the unit. 1) DS16 43 ※Panel thickness: 1.5 to 4mm ● D 60- T Blank Blank H H H H
Failure to follow this instruction may result in fire. 35 ● Panel cut-out Unit (N) A (16N+11) J1 F V = F V =
16N+13
9 3.5 1 27 to ※1: If this data is not for the unit-display unit, it maintains former state.
Caution 6.5 16 6.5 A±0.5
2 43 J8 CT6 MP5 MT4 TK/TX
Series selection
1. Use the unit within the rated specifications. 3 59 1 (manual setting), RS485 Slave Mode (Communication Setting)
Failure to follow this instruction may result in fire or product damage. 4 75 Not using the 1) Application of system organization

23-0.50
2
16

33
24

22
2. Use dry cloth to clean the unit, and do not use water or organic solvent. ③ 3 Terminating resistance
Failure to follow this instruction may result in fire. 5 91 4 highest digit RS232C/
: : USB/Wi-Fi RS485 (100 to 120Ω)
3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, 5
radiant heat, vibration, impact, or salinity may be present. ① No Yes RS485
2) DS22/DA22 J16 Unit-display unit DEVICE
Failure to follow this instruction may result in fire or explosion. 35 ● Panel cut-out Unit (N) A (20N+11)
4. Keep metal chip, dust, and wire residue from flowing into the unit. 20N+13 #31
6.5 20 6.5 3.5 A±0.5 1 31 ※Refer to " RS485 Master Mode".
Failure to follow this instruction may result in fire or product damage. 11.2 Comm. converter
③Input terminal
JP1
2 51
Model 3
4
71
91
S1
S2

No. Code Function No. Code Function
Computer
B (-) A (+)
RS485
B (-) A (+)
RS485
B (-) A (+)
RS485
B (-)
22.5

S3
1 VCC 12-24VDC 4 A(+) RS485 A (+)

31-0.50
1) Basic unit
J1

33
41

30
5 111
J2
J4
J8 2 GND 0V 5 B(-) RS485 B (-) ON OFF DEVICE DEVICE DEVICE
Model Display method Size Model Display method Size : :
J16
#1 #2 #30
3 - -
DS16- T W16×H24mm DA22- T W20×H33mm A (+)※It is recommended to use Autonics communication converter;
※For D 22- T connect the connector to input terminal.
3) DS40/DA40 SCM-WF48 (Wi-Fi to RS485·USB wireless communication converter,
DS22- T W20×H33mm DA40- T 16-segment W40×H60mm 19 ● Panel cut-out
7-segment 40 sold separately), SCM-US48I (USB to RS485 converter, sold separately),
DS40- T W40×H60mm DA60- T W60×H96mm 22.4 2 A±0.5
Unit (N) A (40N-2)
1 38 RS485 Master Mode 2) Modbus Address Mapping SCM-38I (RS232C to RS485 converter, sold separately).
DS60- T W60×H96mm 2 78 Connect the unit and the specified Autonics device which supports Master mode for displaying current value ● Data format Please use twist pair wire for RS485 communication.
2) Expansion unit 3 118 without PC/PLC. Digit 1, 3, 5, ... 23 data Digit 2, 4, 6, ... 24 data
4 158 The specified Autonics devices are connected by auto or manual setting. D7 D6 D5 D4 D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0
Model Display method Size Model Display method Size 5 198
Display may be varied by connection setting. Refer to the below examples. ※Unit, point are displayed when it is ‘H’.
DS16- E W16×H24mm DA22- E W20×H33mm 6 238

55-0.50
1) Supported Autonics device for RS485 Master mode Data
60
40

Unit Dot
54

7 278
DS22- E W20×H33mm DA40- E 16-segment W40×H60mm
8 318 Only for RS485 communication output model of the below series.
7-segment ● Display data
DS40- E W40×H60mm DA60- E W60×H96mm 9 358 Item Series No. (Address) Func. R/W Parameter Parameter name Description Setting range Default
DS60- E W60×H96mm 10 398
Temperature S1 5 400001 (0000) 03/06/16 R/W - Zero Blanking Setting Zero Blanking ON/OFF 0: OFF, 1: ON 0
: : TK, TX, TM2, TM4, THD S2 RS485
※ indicates color: R (red), G (green) controller/sensor S3
J1
4
3 comm.output 400002 (0001) 03/06/16 R/W - Digit 1, 2 1, 2 display data 0
J2
4) DS60/DA60 Counter/Timer CT4, CT6 J4
DEVICE 400003 (0002) 03/06/16 R/W - Digit 3, 4 3, 4 display data 0
Connection of Units
J8 2
Tighten it with below 0.5N.m. 19 ● Panel cut-out J16
400004 (0003) 03/06/16 R/W - Digit 5, 6 5, 6 display data 0
60 Pulse meter MP5 1 JP1

Middle 2
1) DS16/D 22 Expansion 33.6 A±0.5 Panel meter MT4 400005 (0004) 03/06/16 R/W - Digit 7, 8 7, 8 display data 0
bracket
●C  onnect a basic unit, expansion units, a unit-display connector ※Connect input terminal 4(A+) and 5(B-) of display unit to RS485 communication output terminal of the dedicated device. 400006 (0005) 03/06/16 R/W - Digit 9, 10 9, 10 display data 0
unit from the left and connect the caps the end of 400007 (0006) 03/06/16 R/W - Digit 11, 12 11, 12 display data Refer to input 0
2) Example of display
right and left. Cap 400008 (0007) 03/06/16 R/W - Digit 13, 14 13, 14 display data data chart. 0
Cap In case of manual connection setting, the highest digit may be not used.
● The middle bracket (sold separately) helps to protect 400009 (0008) 03/06/16 R/W - Digit 15, 16 15, 16 display data 0
Unit (N) A (60N-3) ● CT6 Series (using 6-digit) ● CT6 Series (using 5-digit)
deflection when connecting over 7 units. 400010 (0009) 03/06/16 R/W - Digit 17, 18 17, 18 display data 0
1 57
Use one middle bracket per 7 units. 2 117 400011 (000A) 03/06/16 R/W - Digit 19, 20 19, 20 display data 0
● The basic unit supplies the power for expansion units 3 177 400012 (000B) 03/06/16 R/W - Digit 21, 22 21, 22 display data 0
91-0.50

Basic unit ● MP5 Series (using 5-digit) ● MP5 Series (using 4-digit) 400013 (000C) 03/06/16 R/W - Digit 23, 24 23, 24 display data 0
60

90

4 237
96

and the unit-display unit and DATA input. Unit-display unit


2) D 40/D 60 Expansion unit 5 297 400014 to 400050 03/06/16 R/W Reserved
6 357
Connect expansion connectors of units using a ribbon cable (accessory) as (Figure 1).
If the distance between expansion units is far as (Figure 2), you can connect the cable at the soldering pad.
7
8
417
477 ● TM4 Series (4CH connection, using unit-display unit)
Cautions during Use
To use a soldering pad, remove the protection cover which only expansion units have. 9 537 1. Follow instructions in 'Cautions during Use'.
Expansion unit Expansion unit 2 Expansion unit 1 10 597 Otherwise, It may cause unexpected accidents.
Basic unit : : 2. 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply
Soldering Soldering
pad pad ● THD Series (using unit-display unit) device.
5) Accessory 6) Sold separately (middle bracket) 3. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the
● DS16 ● D 22 ● D 40/D 60 ● DS16 ● D 22 power.
※You can use both the 7-segment
4. Keep away from high voltage lines or power lines to prevent inductive noise.
display method model and the
In case installing power line and input signal line closely, use line filter or varistor at power line and shielded
Ribbon cable Cable length: Max. 1m 16-segment display method
model mixed.
RS485 Slave Mode (Data Input Method) wire at input signal line.
(Figure 1) (Figure 2) ● E.g.: Displays 10H38M (10 hour 38 minute) Do not use near the equipment which generates strong magnetic force or high frequency noise.
Cap Cap Connector Ribbon cable (50mm) BK-D16R BK-D22R 5. This unit may be used in the following environments.
Removing Protection Cover Comm. address: 1, Comm. speed: 9600bps, Data bit: 8-bit, Start/Stop bit: 1-bit, Parity bit: None
①Indoors (in the environment condition rated in 'Specifications')
To operate the function set switch of the D 40, D 60 models, Unit-display Unit ● Model
Color Red
Basic
unit 1
Expansion
unit 1
Expansion
unit 23
● Query (Master) ②Altitude max. 2,000m
③Pollution degree 2
you should remove the protection cover. This unit is for displaying unit by inserting a name plate. Green Slave Starting Address No. of Register
Size Function ④Installation category I
Press the connection parts (4-point) of the protection cover at the Address
It has only 16, 22 sizes. (sold separately) 16mm DU16-R DU16-G High Low High Low
top/bottom of the product with a flat-head screwdriver and the
protection cover is removed. Flat-head 1) Unit name plate type 22mm DU22-R DU22-G 01H 10H 00H 00H 00H 04H Major Products
screw driver It provides unit-printed name plates as an accessory. You can select the desired unit name plate and insert Photoelectric Sensors Temperature Controllers
Caution: Before removing the protection cover, power must be turned OFF. RS485+
this plate. (Single-stage unit name plate: 19 types, Dual-stage unit name plate: 2 types) RS485- Fiber Optic Sensors Temperature/Humidity Transducers
Comprehensive Device Management Program Byte Data (400001) Data (400002) Data (400003) Data (400004) Error Check (CRC16)
Door Sensors
Door Side Sensors
SSRs/Power Controllers
Counters

[DAQMaster] Item Minimum specifications


IBM PC compatible computer with
Counter High Low High Low High Low High Low Low High Area Sensors
Proximity Sensors
Timers
Panel Meters
System 08H 00H 01H 01H 00H 11H 03H 08H 16H D4H 59H Pressure Sensors Tachometers/Pulse (Rate) Meters
DAQMaster is able to display I/O source value, unit, Pentium Ⅲ or above Dual-stage unit name plate http://www.autonics.com
Rotary Encoders Display Units
and user setting value. Operations Windows 98/NT/XP/Vista/7/8/10 Connector/Sockets Sensor Controllers
Single-stage unit name plate Unit name plate
For more information, please refer to the DAQMater Zero Blanking Switching Mode Power Supplies HEADQUARTERS:
Memory 256MB+ 2) Unit name plate insertion insertion space
user manual. ON Control Switches/Lamps/Buzzers 18, Bansong-ro 513beon-gil, Haeundae-gu, Busan,
Hard disk 1GB+ of available hard disk space Remove the protection sheet and insert I/O Terminal Blocks & Cables
Visit our website (www.autonics.com) to download ● Response (Slave) South Korea, 48002
DAQMaster program. VGA Resolution: 1024×768 or higher the unit name plate at between the case Reflector Stepper Motors/Drivers/Motion Controllers TEL: 82-51-519-3232
Others RS232C serial port (9-pin), USB port and the reflector. Slave Starting Address No. of Register Error Check (CRC16) Graphic/Logic Panels E-mail: sales@autonics.com
Protection Case Function Field Network Devices
※The above specifications are subject to change and some models may be discontinued without notice. sheet Address High Low High Low Low High
※Be sure to follow cautions written in the instruction manual and the technical descriptions Laser Marking System (Fiber, Co₂, Nd:YAG)
01H 10H 00H 00H 00H 04H C1H CAH Laser Welding/Cutting System DRW170316AB