ANNEXURES FOR ITEMS OF BoQ

ANNEXURE-1

Name of work- Supplying, febrication, Instsllstion,Testing and commissioning of


6.00m x 4.00m Size M.S Floating barge of PUB DATTA KUCHI P.W.S.S

Rate = Schedule of rates for repairing/renovation/modification of Steel Vessels/Barge


barge/Pontoons etc under IWT DIRECTORATE ASSAM (2008-09) & PWD SOR 2013-14
Sl No Description of Item Unit Quantity
9 Providing frame work in super structure by cutting angles in reqd. size
welding the same including cost of labour and materials as directed.

a) M.S Angle (65mm x65mmx 6mm)


Bottom 4 x 5.00m =20.00 m
6 x 3.00m =18.00 m
Top
4x 6.00m =24.00 m
6x 4.00 m =24.00 m
Inclined
6 x 1.40 m= 7.40 m
8x 1.40m = 11.20 m
4x 4.00m= 16.00 m
4x 6.00m= 24.00 m
Total= 144.60 m
Wt.11.60 kg/ m=16.77 qntl Qntl 16.77
7 Supply of IS grade 2026 mild steel plate of required size and specific
thickness in keel/bottom hull/side hull etc. in position by cutting ,
bending, straightening etc. in proper shape and sixe and welding the
same including cost of labour and materials etc. complete as directed.
Plate thickness 5 mm and above.

Plate thickness above 5 mm


Bottom
1 x3.00m x 5.00mx0.006m =0..09 cum
Top
1 x6.00m x 4.00mx0.006m =0.14 cum
Total= 0.23 cum
Net wt 1805.50 Kg= 18.06 qntl Qntl 18.06
Plate thickness below 5 mm
Side
2 x 5.00m x 2.40m x 0.005m=0.120 cum
2 x 3.00m x 2.40m x 0.005m=0.072 cum
Total = 0.192 cum
Net wt. 1507.20Kg = 15.07 qntl Qntl 15.07
22 Supplying fitting and fixing of MS pipe/angle of side railing in deck
and super structure of barge complete as directed.

65 mm dia MS pipe for roof frame


6 x 1.80m = 10.8 m
2x 6.00m = 12.00 m
6x 2.5 m =15.00 m
Total = 37.80m
Net wt. 8.01kg/m =302.78 kg= 3.03 qntl Qntl 3.03
22 Supplying fitting and fixing of MS pipe/angle of side railing in deck
and super structure of barge complete as directed.

25 mm dia MS purlin
4x 6.00 m = 24.00 m
Net wt. 2.21kg/m =53.04 kg=0.53 qntl Qntl 0.53
PWD (B) Providing corrugated galvanised iron sheet roofing of TATA SHAKTI
/ SAIL including fitting and fixing necessary galvanised J & I hooks
bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick
and 1.6 mm thick limtet washer complete excluding cost of roof truss,
purlin etc.(roof trusses and purlin etc. to be measured and paid
seperately)

c) 60 mm thick
2 x 6.00 m x 2.10m =25.20 Sqm Sqm 25.2
PWD (B) Providing galvanised iron ridiging of TATA SHAKATI/ SAIL
including supplying and fixing necessary galvanised screws/washers
etc. complete as directed.

(d) 0.60 mm thick


(i) 150 mm lapping r.m. 6
PWD (B) Applying primary coat over new steel and other foreign metal surface
over 100 m in width or girth after preparing the surface by throughly
cleaning oil grease, dirt and other foreign matter and scoured with wire
brushes, fine steels, wood scrapers and sand paper.

a) With ready mixed red-lead/red oxide primer.


Outside
2x5.50m x1.40m=15.40 sqm
2x 3.5m x 1.40m= 9.80 sqm
1x 6.00m x3.50m=21.00 sqm
2x 6.00mx 0.90m=10.80 sqm
2x3.50m x0.90m= 6.30 sqm
Inside
2x5.50m x1.40m=15.40 sqm
2x 3.5m x 1.40m= 9.80 sqm
1x 6.00m x3.50m=21.00 sqm
Total = 109.50 sqm Sqm 109.5
PWD (B) Painting two coats (excluding priming coat) on new steel and other
metal surface with enamel paint of approved brand and
manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
to give an even shade including cleaning the surface of all dirt, dust and
other foreign matter.

b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/
Nerolac). sq.m. 109.5
29 Providing devits on the deck of barge with fitting and fixing complete
including its base frame complete as directed

b) With medium weight No 1


30 Providing capstan of 50 T pulling capacity fiting, fixing on the deck of
barge with necessary base frame fitted with necessary nuts and bolts
etc. complete as directed.

No 2
31 Providing M.S bollard with base frame fitting and fixing on the deck of
barge (B) single bollard of medium size
No 4
13 Mooring materials anchoring devices etc. L.S 1
ANNEXURE-2

Name of Work= Detail estimate for supplying , fitting,fixing 80 mm Dia Raw water
pumping main of PUB DATTA KUCHI WSS
Rate-As per APHE schedule of rates for the year of 2015-16
Sch Particulars
Unit Qnty
no
9.1.1
Earth work in excavation in foundation trenches including refilling the
quantity as necessary after completion of works of pipe line dressing,
ramming, watering etc. and removal of surplus earth with 50 m lead and
lift up to 1.5 m all complete including dewatering as directed including
bailing out water where necessary.

1 x 370.00 m x 0.60m x 1.00m=222.00 Cu.M


(a) In ordinary soil cu.m. 420.00
9.2.4
Labour charge for carrying laying and fixing G.I. pipes complete with
G.I. fittings specials with jointing materials and supplying the jointing
materials all complete as directed excluding trenching and refilling of
earth (external work).

80 mm dia RM 700.00
9.6.4
Labour charge for carrying providing and fixing full way wheel valve of
approved quality with supplying jointing materials all complete as
directed.
80 mm dia Each 1
Cost of Materials
5.1 80 mm dia G.I pipe RM 700.00
6.2.1 80 mm dia G.I socket Each 117
6.2.2 80mm dia G.I union socket Each 3
6.2.4 80 mm dia G.I Bend Each 15
6.2.3 80 mm dia G.I Threaded Flange Each 2
6.2.5 80 mm dia G.I Elbow Each 25
6.2.6
80 mm x 65 mm G.I Reducing socket Each 2
6.2.21 80 mm dia (225 mm long) G.I Nipple Each 2
6.3.15 80 mm dia sluice valve Each 1
2.3 Nuts & Bolts 80 mm dia Each 25
3 mm rubber insertion sheet
2.2 80 mm dia Each 8
ANNEXURE-3

Name of work- Supply and installation of 3.0 HP Centrifugal Raw water pump set with
necessary fittings.
Rate = Estimate prepared as per APWD(Elect) SOR 2013-14 & APHE SOR 20015-16
Sl No Item Unit Quantity
39.4.2
(Elect)
3 HP three phase vertical multistage high pressure centrifugal pump set 8
stage (crompton Greaves/ Aquatic/ CRI/ V-Guard/ Calma make) with DOL
starter (crompton greves & contro switch gear /BCH/ L&T/ Simens make )
fully automatic citation.

3.0 H.P. Three Phase Each 1


32.1
(PWD)

Supplying and laying of following size PVC/XLPE insulated and PVC


sheathed 1.1 KV grade solid Aluminium conductor up to 10 Sq mm balance
standard conductor , XLPE Insulated , cores laid up , PVC tape inner
sheathed , Armour (Aluminium for single core up tpo 70 sq. mm balance
aluminium strip , Galvanized for cable up to 2 X 10 sq.mm , 4 x 6 sq.mm
balance all galvanized steel strip ..................... sand cushioning etc. complete
handling of surplus spoil, debries to proper place as specified and directed by
the Deptt. (Nicco / Havells/ RPG/ CCI/ Polycab/ Gloster/ Finolex make or
equivalent)

32.1.1 2 Core A2 XWaY A2XFaY


32.1.1.1 b) 4.0 sq mm core UG cable RM 65
9.2.4
Labour charge for carrying laying and fixing G.I. pipes complete with
G.I. fittings specials with jointing materials and supplying the jointing
materials all complete as directed excluding trenching and refilling of
earth (external work).

a) 50 mm dia RM 30
9.11.1
Labour charge for cutting and threading G.I. pipes with requird size of
thread including finishing the end all complete as directed.

Qnty=3.14 x 50 x 3 =471.00 mm mm of
dia 471.00
Cost of Materials

5.1
50 mm dia G.I pipe Rm 30.00
6.2.1
50 mm dia G.I socket Each 6
6.2.2
65 mm dia G.I union socket Each 3
6.2.4
50 mm dia G.I Bend Each 4
6.2.3
50 mm dia G.I Flange Each 2
6.2.5
100 mm dia G.I Elbow Each 7

50 mm dia G/M Full wayvalve Each 2


2.3
Nuts & Bolts 65 mm dia Each 25

3 mm rubber insertion sheet


2.2
65 mm dia Each 15
ANNEXURE-4A

Detailed Estimate for Construction of 4 Sq.M Size Treatment Plant of PUB DATTA
KUCHI pipe water supply scheme
Estimate prepared on the basis of APWD(B) Schedule of rates for the year of 2013-14

Sch.No Item of Work Unit Quantity


1.1 Earthwork in excavation for foundation trenches of walls, retaining
walls, footings of column, steps, septic tank etc. including refilling
(return filling) the quantity as necessary after completion of work,
breaking clods in return filling, dressing, watering and ramming etc. and
removal of surplus earth with all lead and lifts as directed and specified
in the following classification of soils including bailing out water where
necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.m. 6.83


2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to
32mm in foundation bed for footing steps, walls, brick works etc. as
directed and specified including dewatering if necessary, and curing
complete (shuttering where necessary shall be measured and paid
separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume Cum
(using mixture machine) 3.03
4.1.1 Providing brick soling in foundation and under floor with stone/ best
quality picked jhama brick, sand packed and laid to level and in panel
after preparing the subgrade as directed including all labour and
materials and if necessary dewatering, complete.

(a).Brick on flat soling. sq.m. 3.44


18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming
to relevant I.S. Code for R.C.C. work/ R.B. walling including
straightening, cleaning, cutting and bending to proper shapes and length
as per details, supplying and binding with 20G annealed black wire and
placing in position with proper blocks, supports, chairs, spacers etc.
complete (upto 1st floor level).

(i) TMT corrosion resistant steel (CRS)


qtl 13.43
c) ISI approved mild steel reinforcement bar (M.S. Bar)
qtl
0.24
3.1.1 Providing form work of ordinary timber planking so as to give a rough
finish including centering, shuttering, strutting and propping etc., height
of propping and centering below supporting floor to ceiling not
exceeding 4.0M and removal of the same for in-situ reinforced concrete
and plain concrete work in:

3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete
works etc.
(i) Using 38mm thick plank sq.m. 11.14
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc.
having plane vertical face
(i) Using 38mm thick plank sq.m. 1.46
3.1.14 Sides and soffits of beams, beam haunchings, cantilever girder,
bressumers, lintels and horizontal ties.

(i) Using 38mm thick plank sq.m. 1.31


3.1.1.5 Flat Surfaces such as soffits of suspended floors, roofs, landings,
cantelever slabs, chajjas, balconies and the like.

(a) Floors etc. upto 200mm in thickness.


(i) Using 38mm thick plank sq.m. 9.61
3.1.1.8 Vertical surface such as walls (any thickness), parapet walls, partitions,
walls of septic tank, inspection pit and the like including attached
pilasters, butresses, plinth and string courses and the like.

(i) Using 38mm thick plank sq.m. 19.44


3.1.1.10 Staircase with sloping or stepped soffits including risers and stringers
but excluding Landing. (Using 38mm thick plank) sq.m. 2.20
2.2.1 Providing and laying plain/reinforced cement croncrete works cement
with coarse sand & 20mm down graded stone aggregate including
dewatering if necessary, and curing complete but excluding cost of form
work and reinforcement for reinforced cement concrete work (form
work and reinforcement will be measured and paid separately)

(I) Using mixture machine


(A) In sub - structure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap,
base slab, retaining walls, walls of septic tank, inspection pit and the
like and other works not less than 100mm thick up to plinth level.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 3.05
(B) Super-structure from plinth level upto 1st floor level.

(i) Walls (thickness not less than 100mm) including attached pillasters,
buttresses, plinth and string course etc.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 6.24
(ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and
support, balcony, lintel, sill band, beam, girder, bressumer, cantilever,
staircase (except spiral staircase and landing ) including preparing the
top surface and finishing of nosing.

N) Without using admixture, plasticiser


(b) M20 grade concret or Prop. 1:1.5:3 Cum 1.26
22.2.5 Extra for providing and mixing normal Plastisizer Plastiment BV 40 of
Sika India Ltd. / Dr Sealkit Super plast WR 40 (Assian Chemicals)/
Rheobuild 1100 i of BAST @ 0.5%-0.8% by weight of cement in
concrete for waterproofing structures like roof slabs, basement, sunken
slabs, chajjas, tunnels, water tank etc. as specified and directed by the
Department complete at all levels.

(iii) In 1 : 1 : 2 (1cement : 1coarse sand : 2aggregate) or M-25 grade.


cu.m. 7.50
4.1.4 Brick work in cement morter with 1st class brick including racking out
joints and dewatering if necessary, and curing complete as directed

(I) In sub-structure up to plinth level including dewatering if


necessary
(b). In proportion 1:4.
cu.m.
9.16
6.2.3 20 mm thick Cement plaster in two coats, on single or half brick walls
for interior plastering up to 1st floor level including arises, internal
rounded angles,chamfers and / or rounded angles not exceeding 80mm
in girth and finished even and smooth including curing complete as
directed.

A) On rough side (backing coat 15 mm and finishing coat 5 mm


thick)
(b). In cement mortar 1:4 sq.m.
43.92
A) On fair side (backing coat 10 mm and finishing coat 10 mm
thick)

(b). In cement mortar 1:4 sq.m. 83.88


1.3 Earth/ sand filling in plinth in layers not more than 150mm thick
including necessary carriage, watering, ramming etc. complete as
directed and specified including payment of land compensation, forest
royalty, sales tax and other duties and taxes as may be necessary.

( c) With river sand or silt (predominently non plastic) by truck carriage


including loading to the site of work
cu.m. 30.83

13.9.1 Finishing old / new wall with water proofing weather coat smooth anti-
fungal exterior painting of approved make of Berger paint of required
shade after cleaning and clearing the surface etc. including scaffolding
complete as directed at all levels (two coats)
sq.m. 57.67
3.1.1(san)13- Supplying fitting fixing G.I pipes of following sizes, with all necessary
14 "R" brand or similar approved G.I fittings such as bend, tee,
elbow,reducer, nipple, plug, long screw fitting, H.W clamp etc.complete
at all levels including below G.L as directed and specified.

(A) Exposed or in trenches


c) 32 mm dia (Midium) (using TATA )
RM 31.90

ANNEXURE-4B

Name of work- Construction of Sedimentation tank of PUB DATTA KUCHIWater


supply Scheme
Rate = As per A.P. W.D (build) schedule of rates for the year 2013-14

Sch.No Particulars Unit Quantity


1.1 Earthwork in excavation for foundation trenches of walls, retaining walls,
footings of column, steps, septic tank etc. including refilling (return filling)
the quantity as necessary after completion of work, breaking clods in return
filling, dressing, watering and ramming etc. and removal of surplus earth with
all lead and lifts as directed and specified in the following classification of
soils including bailing out water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.m. 61.14


4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing
the subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(a).Brick on flat soling. sq.m. 29.60


2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm
in foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using
mixture machine) Cum 4.80

3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of propping
and centering below supporting floor to ceiling not exceeding 4.0M and
removal of the same for in-situ reinforced concrete and plain concrete work
in:

3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete
works etc.
(i) Using 38mm thick plank sq.m. 9.32
3.1.1.8 Vertical surface such as walls (any thickness), parapet walls, partitions, walls
of septic tank, inspection pit and the like including attached pilasters,
butresses, plinth and string courses and the like.

(i) Using 38mm thick plank sq.m. 180.67


2.2.1 Providing and laying plain/reinforced cement croncrete works cement with
coarse sand & 20mm down graded stone aggregate including dewatering if
necessary, and curing complete but excluding cost of form work and
reinforcement for reinforced cement concrete work (form work and
reinforcement will be measured and paid separately)

(I) Using mixture machine


(A) In sub - structure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base
slab, retaining walls, walls of septic tank, inspection pit and the like and other
works not less than 100mm thick up to plinth level.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 6.68
(B) Super-structure from plinth level upto 1st floor level.

(i) Walls (thickness not less than 100mm) including attached pillasters,
buttresses, plinth and string course etc.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 18.16
Market Providing Aluminium Water Stopper of 150mm width in wall construction
joints , made out of 14 swg aluminium plain sheet , placing, fixing in position,
to ensure water tightness in the construction joints, all complete as per
specification. RM 110.4

18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to


relevant I.S. Code for R.C.C. work/ R.B. walling including straightening,
cleaning, cutting and bending to proper shapes and length as per details,
supplying and binding with 20G annealed black wire and placing in position
with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor
level).

b) Other ISI approved TMT reinforcement bar (SRMB/SAI/BISCON/X


TECH) (For Assam Type Bldg. Drain works, retaining wall & Boundary wall
etc.) qtl 32.75

6.2.3 20 mm thick Cement plaster in two coats, on single or half brick walls for
interior plastering up to 1st floor level including arises, internal rounded
angles,chamfers and / or rounded angles not exceeding 80mm in girth and
finished even and smooth including curing complete as directed.

A) On rough side (backing coat 15 mm and finishing coat 5 mm thick)

(b). In cement mortar 1:4 sq.m. 155.24


A) On fair side (backing coat 10 mm and finishing coat 10 mm thick)
(b). In cement mortar 1:4 sq.m. 93.25
13.9.1 Finishing old / new wall with water proofing weather coat smooth anti-fungal
exterior painting of approved make of Berger paint of required shade after
cleaning and clearing the surface etc. including scaffolding complete as
directed at all levels (two coats) sq.m. 78.25

Earth/ sand filling in plinth in layers not more than 150mm thick including
necessary carriage, watering, ramming etc. complete as directed and specified
1.3
including payment of land compensation, forest royalty, sales tax and other
duties and taxes as may be necessary.

( c) With river sand or silt (predominently non plastic) by truck carriage including
loading to the site of work cu.m. 53.00

Analysis Construction of brick masonary valve chamber with 23 cm 1 st class brick in


prop. 1:4 finished with 10 mm thick cement plastering prop. 1 :4 inside wall
in floor including necessary earth work in excavation and refilling the sides of
the same after completion of brick work. The size of chamber 60cm x 60cm x
120 cm inside with a RCC cover slab in 10 tor T.S @150 mm c/c both ways
binding with black wire. Brick flat soling with 1:3:6 in the base of chamber
complete as per specification and drawing approved by the Deptt.

Each 2
9.6.1
Labour charge for carrying, placing in position, fitting and fixing C.I.
sluice valve (with wheel & cap) C.I. reflex valve complete with
supplying bolts and nuts, 3 mm thick rubber insertion sheet etc. (the tail
pieces if required will be paid separately) all complete as directed (one
valve and two flanged joints).

150 mm dia Each 2

CI D/F SLUICE VALVE WITH CAP/ WHEEL AS PER IS 14846/2000 PN


6.3.15 1.0 WITH ISI MARKING

150 mm dia Each 2


6.1.10 UPVC Tail Piece
(d) 110mm Each 12
ANNEXURE-4C

Name of work-Construction of Cascade type aerator of PUB DATTA KUCHIWater


supply Scheme

As per A.P. W.D (build) schedule of rates for the year 2013-14
Sch.No Item of work Unit Qnty
1.1 Earth work in excavation for foundation, trenches of walls,retaining walls,
footing of columns,steps, septic tank etc. including refilling (return filling) the
quantity as necessary after completion of work, breaking clods in return
filling, dressing, watering and ramming etc and removal of removal of surplus
earth with all lead and lifts as directed and specified in the following
classification of soils including bailing out water where necessary as directed
and specified.

A) up to a depth of 2m below the existing ground level

(a) In ordinary soil cu.m. 22.43


2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

a) In prop. 1;3;6 Cu.M. 1.13


4.1.1 Providing soling in foundation and under floor at all levels with stone/ best
(a) quality picked jhama bricks, sand packed and laid to level and in pannel after
preparing the sub grade as directed including all labour and materials , and
dewatering complete

a) Brick flat soling Sq.M 7.54


18.1 Supplying, fitting and fixing in position reinforcement bars conforming to
relevant I.S. Code for R.C.C. work/ R.B. walling including straightening,
cleaning, cutting and bending to proper shapes and length as per details,
supplying and binding with 20G annealed black wire and placing in position
with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor
level).

a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL

(i) TMT corrosion resistant steel (CRS) qtl 5.64


3.1.1 Providing form work of ordinary timber planking so as to give a rough
finished including centering, shuttering, sthutting and propping etc. height of
propping and centering below supporting floor to ceiling not exceeding 4 m
and removal of the same for in- situ reiforcement work)

Foundation ,footing, base of column, tie beam pile cap raft, walls of septic
tank, inspection pit and the like up to plinth level.

using 38 mm thick plank Sq.M 3.82


Column pillar post & struts
Square, Rectangular,Polygonal in plan or any shape like Tee/L etc. having
plane vertical etc.
using 38 mm thick plank Sq.M 19.20
2.3.2
Providing and laying plain/reinforced cement concrete works cement with
coarse sand & , 20mm down including dewatering if necessary and curing
complete but excluding cost of form wood and reinforcement for reinforced
cement

(I) In substructure up to plinth level


(A) Foundation, footing, columns with base, tie and plinth beam, grade beam,
pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the
like and other works not less than 100mm thick.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 1.47
B) In superstructure from plinth level up to Ist floor level.
(B) Columns, pillars. Posts, struts, suspended floor, roof, shell and support,
beam, girder, bressumer, cantilever, including preparing of surfaces and
furnishing and nosing.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 0.83
(B) Walls (thickness not less than 100mm) including attached pillasters,
buttresses, plinth and string course etc.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 1.78
4.1.4 Brick work in cement morter with 1st class brick including racking out joints
and dewatering if necessary, and curing complete as directed

(I) In sub-structure up to plinth level including dewatering if necessary

(b). In proportion 1:4. cu.m. 0.68


6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall …..
internal rounded angles, not exceeding 80mm girth and finished even and
smooth including curing complete as directed.

A) On rough side
(b). In cement mortar 1:4 sq.m. 24.65
13.9.1 Finishing old / new wall with water proofing weather coat smooth anti-fungal
exterior painting of approved make of Berger paint of required shade after
cleaning and clearing the surface etc. including scaffolding complete as
directed at all levels (two coats) sq.m. 17.83

Analysis Supplying,and fitting fixing embeded in the RCC shaft column of 200 mm dia
D.I pipe in cascade type aerator, including necessary fittings such as bend,Tee
etc where necessary as directed by the deptt.

Job 1
ANNEXURE-4D

Providing and laying 100 mm dia D.I pipe ambeded in side shaft column of cascade
type aerator.
Sl no Particulars Unit Qnty
cost of materials
5.6 D.I. Pipe (Class K-7)
100 mm dia Rm 6.2
6.4.9 DI DOUBLE SOCKET DUCK FOOT BEND
(a) Up to 300 mm
100 mm dia Qnty= 1 No
Wt. 42 Ks Each Per Kg 42
6.4.15 DI MECHANICAL JOINT COLLER
(a) Up to 300 mm
100 mm dia= 3 nos X 32Kg/E= 96Kg Per Kg 96
6.4.4 Ductile Iron Flange as per IS : 9523/2000
(a) 100 mm -200 mm
100 mm dia= 4 nos X 11Kg each= 44.00Kg Per Kg 44
RUBBER GASKET FOR DI PIPE CONFORMING TO
6.4.18
BIS :5832/85
100 mm dia Qnty= 4 Nos Each 4
ANNEXURE-4E

Name of work-Construction of Flash Mixer of PUB DATTA KUCHIWater supply


Scheme

As per A.P. W.D (build) schedule of rates for the year 2013-14
Sch.No Item of work
Unit Qnty
1.1 Earth work in excavation for foundation, trenches of walls,retaining walls,
footing of columns,steps, septic tank etc. including refilling (return filling) the
quantity as necessary after completion of work, breaking clods in return filling,
dressing, watering and ramming etc and removal of removal of surplus earth
with all lead and lifts as directed and specified in the following classification of
soils including bailing out water where necessary as directed and specified.

A) up to a depth of 2m below the existing ground level

(a) In ordinary soil cu.m. 14.27


2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

a) In prop. 1;3;6 Cu.M. 1.38


4.1.1 Providing soling in foundation and under floor at all levels with stone/ best
(a) quality picked jhama bricks, sand packed and laid to level and in pannel after
preparing the sub grade as directed including all labour and materials , and
dewatering complete

a) Brick flat soling


Sq.M 10.84
18.1 Supplying, fitting and fixing in position reinforcement bars conforming to
relevant I.S. Code for R.C.C. work/ R.B. walling including straightening,
cleaning, cutting and bending to proper shapes and length as per details,
supplying and binding with 20G annealed black wire and placing in position
with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor
level).

a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL

(ii) Super ducktile (SD) TMT Reinforcement bar qtl 7.31


3.1.1 Providing form work of ordinary timber planking so as to give a rough finished
including centering, shuttering, sthutting and propping etc. height of propping
and centering below supporting floor to ceiling not exceeding 4 m and removal
of the same for in- situ reiforcement work)

Foundation ,footing, base of column, tie beam pile cap raft, walls of septic tank,
inspection pit and the like up to plinth level.

using 38 mm thick plank


Sq.M 0.35
3.1.1.8 Vertical surface such as walls (any thickness), parapet walls, partitions, walls of
septic tank, inspection pit and the like including attached pilasters, butresses,
plinth and string courses and the like.

using 38 mm thick plank Sq.M 58.06


2.3.2
Providing and laying plain/reinforced cement concrete works cement with
coarse sand & , 20mm down including dewatering if necessary and curing
complete but excluding cost of form wood and reinforcement for reinforced
cement

(I) In substructure up to plinth level


(A) Foundation, footing, columns with base, tie and plinth beam, grade beam,
pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the
like and other works not less than 100mm thick.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 1.23
(B) Walls (thickness not less than 100mm) including attached pillasters,
buttresses, plinth and string course etc.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 5.57
6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall …..
internal rounded angles, not exceeding 80mm girth and finished even and
smooth including curing complete as directed.

A) On rough side
(b). In cement mortar 1:4 sq.m. 53.88
13.9.1 Finishing old / new wall with water proofing weather coat smooth anti-fungal
exterior painting of approved make of Berger paint of required shade after
cleaning and clearing the surface etc. including scaffolding complete as
directed at all levels (two coats)
sq.m. 42.89

Analysis

Construction of brick masonary valve chamber with 23 cm 1 st class brick in


prop. 1:4 finished with 10 mm thick cement plastering prop. 1 :4 inside wall in
floor including necessary earth work in excavation and refilling the sides of the
same after completion of brick work. The size of chamber 60cm x 60cm x 120
cm inside with a RCC cover slab in 10 tor T.S @150 mm c/c both ways binding
with black wire. Brick flat soling with 1:3:6 in the base of chamber complete as
per specification and drawing approved by the Deptt.

Each 1
9.6.1
Labour charge for carrying, placing in position, fitting and fixing C.I.
sluice valve (with wheel & cap) C.I. reflex valve complete with
supplying bolts and nuts, 3 mm thick rubber insertion sheet etc. (the tail
pieces if required will be paid separately) all complete as directed (one
valve and two flanged joints).

150 mm dia Each 1

CI D/F SLUICE VALVE WITH CAP/ WHEEL AS PER IS 14846/2000 PN


6.3.15
1.0 WITH ISI MARKING

100 mm dia Each 1


5.1 100 mm dia GI pipe (Sludge outlet pipe) Rm 5
6.2.5 100 mm dia GI elbow Each 2
6.2.3 100 mm dia GI threaded flange Each 2

ANNEXURE-4F

Name of work- Construction of RCC Channel of PUB DATTA KUCHI Water supply
Scheme

As per A.P. W.D (build) schedule of rates for the year 2013-14
Sch.No Particulars Unit Quantity
1.1 Earthwork in excavation for foundation trenches of walls, retaining walls,
footings of column, steps, septic tank etc. including refilling (return filling) the
quantity as necessary after completion of work, breaking clods in return filling,
dressing, watering and ramming etc. and removal of surplus earth with all lead
and lifts as directed and specified in the following classification of soils
including bailing out water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.m. 13.31


4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing
the subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(a).Brick on flat soling. sq.m. 5.76


2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using
mixture machine) Cum 0.58

3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of propping
and centering below supporting floor to ceiling not exceeding 4.0M and
removal of the same for in-situ reinforced concrete and plain concrete work in:

3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works
etc.
(i) Using 38mm thick plank sq.m. 8.64
3.1.1.3 Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having
plane vertical face
(i) Using 38mm thick plank sq.m. 26.40
3.1.1.8 Vertical surface such as walls (any thickness), parapet walls, partitions, walls of
septic tank, inspection pit and the like including attached pilasters, butresses,
plinth and string courses and the like.

(i) Using 38mm thick plank sq.m. 21.60


2.2.1 Providing and laying plain/reinforced cement croncrete works cement with
coarse sand & 20mm down graded stone aggregate including dewatering if
necessary, and curing complete but excluding cost of form work and
reinforcement for reinforced cement concrete work (form work and
reinforcement will be measured and paid separately)

(I) Using mixture machine


(A) In sub - structure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base slab,
retaining walls, walls of septic tank, inspection pit and the like and other works
not less than 100mm thick up to plinth level.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 1.15
(B) Super-structure from plinth level upto 1st floor level.

(i) Walls (thickness not less than 100mm) including attached pillasters, buttresses,
plinth and string course etc.

N) Without using admixture, plasticiser


(c) M25 grade concrete Cum 3.22
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to
relevant I.S. Code for R.C.C. work/ R.B. walling including straightening,
cleaning, cutting and bending to proper shapes and length as per details,
supplying and binding with 20G annealed black wire and placing in position
with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level).

a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL

(i) TMT corrosion resistant steel (CRS) qtl 5.00


6.2.3 20 mm thick Cement plaster in two coats, on single or half brick walls for
interior plastering up to 1st floor level including arises, internal rounded
angles,chamfers and / or rounded angles not exceeding 80mm in girth and
finished even and smooth including curing complete as directed.

A) On fair side (backing coat 10 mm and finishing coat 10 mm thick)

(b). In cement mortar 1:4 sq.m. 46.72


13.9.1 Finishing old / new wall with water proofing weather coat smooth anti-fungal
exterior painting of approved make of Berger paint of required shade after
cleaning and clearing the surface etc. including scaffolding complete as directed
at all levels (two coats) sq.m. 36.32

--------------------------
ANNEXURE-5A

Name of Work= Detail estimate for supplying , fitting,fixing of internal connection


between TP & UGR of PUB DATTA KUCHI Pipe Water Supply Scheme.

As per APHE schedule of rates for the year of 2015-16 and analysis rate

Sch no Particulars Unit Qnty


9.1.1

Earth work in excavation in foundation trenches including refilling the


quantity as necessary after completion of works of pipe line dressing,
ramming, watering etc. and removal of surplus earth with 50 m lead and
lift up to 1.5 m all complete including dewatering as directed including
bailing out water where necessary.

1 x 1 x 18.00 m x 0.60m x 0.90m=9.72 Cu.M


(a) In ordinary soil cu.m. 9.72
9.2.4
Labour charge for carrying laying and fixing G.I. pipes complete with
G.I. fittings specials with jointing materials and supplying the jointing
materials all complete as directed excluding trenching and refilling of
earth (external work).

100mm dia Qnty= 1 x 22.00m =22.00 M


RM 22.00
150mm dia Qnty= 1 x 18.00m =18.00 M RM 18.00
9.2.7

Labour charge for carrying and laying in position in trenches P.V.C.


pipes with specials in lines and level including cutting the pipes where
necessary and providing joints to pipes and specials with jointing
materials such as cement lubricant after roughening the surfaces
including the cost of jointing materials and testing the joints all complete
as directed

75 mm dia Qnty= 1 x 20.00m =20.00 M


Rm 20.00
Analysis Construction of brick masonary valve chamber with 23 cm 1 st class brick in
(A) prop. 1:4 finished with 10 mm thick cement plastering prop. 1 :4 inside wall in
floor including necessary earth work in excavation and refilling the sides of the
same after completion of brick work. The size of chamber 60cm x 60cm x 120
cm inside with a RCC cover slab in 10 tor T.S @150 mm c/c both ways
binding with black wire. Brick flat soling with 1:3:6 in the base of chamber
complete as per specification and drawing approved by the Deptt.

1 x 4 nos= 4 nos Each 4

Making and Supplying of UPVC perforated laterals of 50mm dia and 60


cm long by making hole of 5mm dia at a spacing of 8 cm centre to
centre in two lines at 60’ with the centre of the pipe and threading at
10.6.2 both ends and supplying, fitting and fixing 40mm dia U.P.V.C. threaded Pair 8
End Plug at one end, the other end to be fitted with a UPVC threaded
nipple of 75 mm long properly embedded in RCC cover slab all
complete as directed.

25.12 Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4
(PWD) reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20
gauge black annealed wire with necessary shuttering , curing etc. complete
including fixing in position as directed.

Qnty= (2 x 2.00m x 0.75 m ) = 3.0 sqm

b) 75mm thick slab sq.m. 3.00


10.2.2 Supplying and placing of filter sand of hard and resistant quartz, uniform
size and shape free from dust, clay, soft grains, dirt and any other
foreign materials includind inorganic salt and organic substance, washed
and screened. Having uniformity coefficient between 1.3 to 1.7,
effective size between 0.45 to 0.70mm, ignition loss not exceeding 0.7%
by weight, soluble fraction in Hydrochloric acid not exceeding by 5% by
weight, silica content not less than 90%, specific gravity between 2.55 to
2.65, wearing loss less than 3% as per IS: 1419 (Part-I):1977 all
complete as directed.

Qnty= 2 x 2.00m x 1.50m x 0.60m =3.60 Cu.m Cu.M 3.6


10.2.1 Supplying and placing of filter gravel of uniform size and shape without
flaxy shape free from dust , clay, soft grains, dirt and other foreign
materials, washed and screened to different sizes as given below as per
IS 8419 (Part-I) : 1977 all complete as directed.

a) Size from 2 mm to 6 mm
2 x 1.65 x 1.25 x 0.10 =0.60 cum
Cum 0.4125
b) Size from 7 mm to 12 mm
2 x 1.65 x 1.25 x 0.10 =0.60 cum
Cum 0.4125
c) Size from 13 mm to 25 mm
2 x 1.65 x 1.25 x 0.10 =0.60 cum
Cum 0.4125
c) Size from 25 mm to 32 mm
2 x 1.65 x 1.25 x 0.10 =0.60 cum
Cum 0.4125
d) Size from 25 mm to 32 mm
2 x 1.65 x 1.25 x 0.10 =0.60 cum
Cum 0.4125
Cost of Materials
150 mm dia G.I pipe
RM 18
100 mm dia G.I pipe
RM 22
75 mm dia PVC pipe
RM 20
150 mm dia CIDE S/valve
Each 4
100 mm dia CIDE S/valve
Each 3
80 mm dia CIDE S/valve
Each 1
150 mm dia G.I Socket
Each 2
100 mm dia G.I Socket
Each 10
150 mm dia G.I nipple, 225 mm long
Each 6
100 mm dia G.I nipple, 225 mm long
Each 6
150 mm dia G.I Bend 90
Each 6
100 mm dia G.I Bend 90
Each 8
150 mm dia G.I Flange
Each 4
100 mm dia G.I Flange
Each 5
80 mm dia G.I Flange
Each 4
150 x 100 mm dia G.I reduceing socket
Each 1
75 mm dia PVC E/cap
Each 3
Nuts & Bolts 150 mm dia
Each 65
Nuts & Bolts 100 mm dia
Each 40
Nuts & Bolts 80 mm dia
Each 11
3 mm rubber insertion sheet
150 mm dia
Each 15
100 mm dia
Each 9
80 mm dia
Each 6
ANNEXURE-5B

Brick masonary valve chamber inside clear area 900 mm x 900 mm x 1250 mm
including precast slab over the chamber.

As per APWD (Build) SOR 2013-14


Sch Particulars Qnt
Unit
no y
1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of
column, steps, septic tank etc. including refilling (return filling) the quantity as
necessary after completion of work, breaking clods in return filling, dressing,
watering and ramming etc. and removal of surplus earth with all lead and lifts as
directed and specified in the following classification of soils including bailing out
water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

Qnty= 1 x 1.55m x 1.55 m x 1.40m =3.66cum


(a) In ordinary soil cu.m
. 3.36
4.1.1 Providing brick soling in foundation and under floor with stone/ best quality picked
jhama brick, sand packed and laid to level and in panel after preparing the subgrade
as directed including all labour and materials and if necessary dewatering, complete.

Qnty= 1 x 1.55m x 1.55 m =2.40 Sqm


(a).Brick on flat soling. sq.m
. 2.40
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and specified
including dewatering if necessary, and curing complete (shuttering where necessary
shall be measured and paid separately).

Qnty= 1 x 1.55m x 1.55 m x 0.10m =0.24cum


(b). In prop. 1:4:8 (1 cement:4 coarse sand : 8 coarse agg. by volume (using mixture 0.24
machine) Cum
0
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and
dewatering if necessary, and curing complete as directed

(I) In sub-structure up to plinth level including dewatering if necessary

Qnty=
1 x 2 x 1.40 x 0.25 x 1.15 =0.81 Cum
1 x 2 x 0.90 x 0.25 x 1.15 =0.52 Cum
1 x 2 x 1.40 x 0.112 x 0.10 =0.03 Cum
1 x 2 x 0.90 x 0.112 x 0.10 =0.02 Cum
Total=1.38 Cum
(c). In proportion 1:5. cu.m
1.38
.
6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering
up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and
finished even and smooth including curing complete as directed.

A) On rough side
Qnty= For inside plastering
1 x 4 x 0.90 x 1.25 = 4.50 Sqm
(b). In cement mortar 1:4 sq.m
. 4.5
B) On fair side
Qnty For outside plastering
1 x 4 x 1.40 x 0.15 = 0.84 Sqm
(b). In cement mortar 1:4 sq.m
. 0.84
25.1 Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced
2 with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black
annealed wire with necessary shuttering , curing etc. complete including fixing in
position as directed.

1 x 1 x 1.12 x 1.12 = 1.25 Sqm


b) 100 mm thick slab sq.m
. 1.25

---------------------------
ANNEXURE-6

Name of work- Construction of 40,000 lits capacity Clear Water Underground


Sump of PUB DATTA KUCHI PWSS .

As per A.P. W.D (build) schedule of rates for the year 2013-14
Sch.No Particulars Uni Quanti
t ty
1.1 Earthwork in excavation for foundation trenches of walls, retaining walls,
footings of column, steps, septic tank etc. including refilling (return filling)
the quantity as necessary after completion of work, breaking clods in return
filling, dressing, watering and ramming etc. and removal of surplus earth with
all lead and lifts as directed and specified in the following classification of
soils including bailing out water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.


80.08
m.
4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing
the subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(a).Brick on flat soling. sq.


23.04
m.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm
in foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using Cu
mixture machine) 3.46
m
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of propping
and centering below supporting floor to ceiling not exceeding 4.0M and
removal of the same for in-situ reinforced concrete and plain concrete work
in:

3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete
works etc.
(i) Using 38mm thick plank sq.
2.88
m.
3.1.1.2 Sides of tie beams, grade beams etc. at or below ground level.

(i) Using 38mm thick plank sq.


17.10
m.
3.1.1.3 Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having
plane vertical face
(i) Using 38mm thick plank sq.
19.09
m.
3.1.1.4 Sides and sofits of beams, beam haunchings, cantiliver girders, bressumers,
lintels and horizontal ties.

Using 38mm thick plank sq.


19.80
m.
3.1.1.5 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever
slabs, chajjas, balconies and the like.

(a) Floors etc. upto 200mm in thickness.


(i) Using 38mm thick plank sq.
12.96
m.
3.1.1.8 Vertical surface such as walls (any thickness), parapet walls, partitions, walls
of septic tank, inspection pit and the like including attached pilasters,
butresses, plinth and string courses and the like.

(i) Using 38mm thick plank sq.


91.10
m.
3.1.1.10 Staircase with sloping or stepped soffits including risers and stringers but
excluding Landing. (Using 38mm thick plank) sq.
7.95
m.
2.2.1 Providing and laying plain/reinforced cement croncrete works cement with
coarse sand & 20mm down graded stone aggregate including dewatering if
necessary, and curing complete but excluding cost of form work and
reinforcement for reinforced cement concrete work (form work and
reinforcement will be measured and paid separately)

(A) In sub - structure up to plinth level


Foundation, footing, columns with base tie and plinth beam, pile cap, base
slab, retaining walls, walls of septic tank, inspection pit and the like and other
works not less than 100mm thick up to plinth level.

P) Using admixture, plasticiser etc for air entraining, water reducing purposes
including addition of agent for changing normal setting time of concrete as
required.

(c) M25 grade concrete Cu


5.08
m
(B) Super-structure from plinth level upto 1st floor level.

P) Using admixture, plasticiser etc for air entraining, water reducing purposes
including addition of agent for changing normal setting time of concrete as
required.

(i) Walls (thickness not less than 100mm) including attached pillasters,
buttresses, plinth and string course etc.

(c) M25 grade concrete Cu


6.83
m
(ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and
support, balcony, lintel, sill band, beam, girder, bressumer, cantilever,
staircase (except spiral staircase and landing ) including preparing the top
surface and finishing of nosing.

P) Using admixture, plasticiser etc for air entraining, water reducing purposes
including addition of agent for changing normal setting time of concrete as
required.

(c) M25 grade concrete Cu 4.46


m
Roof slab
N) Without using admixture, plasticiser
(b) M20 grade concret or Prop. 1:1.5:3 Cu
6.83
m
1.46(sa Providing fitting and fixing 450 mm dia . 90 mm thick C.I Man hole cover
ni) and frame of 58 kg. weight complete as directed and specified. Eac
1.00
h

18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to


relevant I.S. Code for R.C.C. work/ R.B. walling including straightening,
cleaning, cutting and bending to proper shapes and length as per details,
supplying and binding with 20G annealed black wire and placing in position
with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor
level).

a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL

(i) TMT corrosion resistant steel (CRS) qtl 20.05


PHE Supplying, fitting & fixing in position 100mm dia, GI air vent pipes of about
1.00m high fitted with necessary bend etc. over top slab, complete in all
respects as directed. RM 1.0

6.2.3 20 mm thick Cement plaster in two coats, on single or half brick walls for
interior plastering up to 1st floor level including arises, internal rounded
angles,chamfers and / or rounded angles not exceeding 80mm in girth and
finished even and smooth including curing complete as directed.

A) On fair side (backing coat 10 mm and finishing coat 10 mm thick)

(b). In cement mortar 1:4 sq.


m. 52.00
A) On rough side (backing coat 15 mm and finishing coat 5 mm thick)

(b). In cement mortar 1:4 sq.


m. 48.17
13.9.1 Finishing old / new wall with water proofing weather coat smooth anti-fungal
exterior painting of approved make of Berger paint of required shade after
cleaning and clearing the surface etc. including scaffolding complete as
directed at all levels (two coats) sq.
25.78
m.

10.2 Providing, fitting and fixing M.S. grill of requiredpattern for windows/
clerestory windows/ openingwith M.S. flats at required spacing in frame all
round, squre or round M.S. bars with round headed bolts and nuts or
screws.

I . Plain grill (Around the UGR)


(c). Fixed to Brickwork/P.C.C/R.C.C. kg 181.83
ANNEXURE-7

Name of Work: Detail estimate for Chlorination of PUB DATTA KUCHI PWSS.
Sch Particulars
Unit Qnty
no
1 Specification of Item
Supply and installation of solenoid feed dozing pump of 6 lit capacity
having pressure 6 kg/Sq. Cm of approved brand and make along with
synchronized solution tank mixing container of 100 lits capacity
complete with all electrical wiring with panel board fitting fixing at site ,
commissioning and testing to be done at cost and risk of contractor
pump should have single phase electrical / diesel power supply
provision only.

Standard materials for construction


1. Housing- Fiber reinforced plastic
2. Spacer and head - Polyproylene/UPVC
3. Diaphram- Teflon Faced
4. Ball- PTEE
5. Suction and dischaege Ball cartidge- Polyproylene/UPVC
6. Solution and discharging Tubing - HDPE/LLPEE
Job 1
7. MS Febrication stand for mixing container
ANNEXURE-8

Name of work- Construction of Clear water Pump House over Under Ground Sump
at PUB DATTA KUCHI P.W.S.S

As per A.P. W.D (build) schedule of rates for the year 2013-14
Sch
No Description of Item Unit Quantity
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to
relevant I.S. Code for R.C.C. work/ R.B. walling including straightening,
cleaning, cutting and bending to proper shapes and length as per details,
supplying and binding with 20G annealed black wire and placing in position
with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor
level).

a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL

(i) TMT corrosion resistant steel (CRS) qtl 2.76


c) ISI approved mild steel reinforcement bar (M.S. Bar) qtl 0.58
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of propping
and centering below supporting floor to ceiling not exceeding 4.0M and
removal of the same for in-situ reinforced concrete and plain concrete work
in:

(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having
plane vertical face
(ii) Using 25mm thick plank sq.m. 8.68
3.1.1. Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever
5 slabs, chajjas, balconies and the like.

(a) Floors etc. upto 200mm in thickness.


(ii) Using 25mm thick plank sq.m. 25.82
2.2.1 Providing and laying plain/reinforced cement croncrete works cement with
coarse sand & 20mm down graded stone aggregate including dewatering if
necessary, and curing complete but excluding cost of form work and
reinforcement for reinforced cement concrete work (form work and
reinforcement will be measured and paid separately)

(B) Super-structure from plinth level upto 1st floor level.


(ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and
support, balcony, lintel, sill band, beam, girder, bressumer, cantilever,
staircase (except spiral staircase and landing ) including preparing the top
surface and finishing of nosing.

P) Using admixture, plasticiser etc


(b) M20 grade concret or Prop. 1:1.5:3 Cum 1.68
18.3.1 Providing fitting, hoisting and fixing of roof trusses including purlins
fabricated out of M.S. circular hollow section conforming to relevant I.S.
code, as per approved design and drawings including providing M.S. cleats,
base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer
and two coats of approved enamel paints complete including fitting necessary
cleats etc. for fixing ceiling joists as per design and drawing as directed.

a) TATA make Circular hollow section - CHS of grade YST-310 conforming


to I:S Specification : 1161-1998 qtl 2.81

8.1.35 Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels
including fitting and fixing self drilling, self tapping screws complete (Roof
trusses, purlins etc. to be measured and paid separately.) .TATA Blue
scope/Dyna roof / Wonder Roof or equivalent as directed by the Deptt.

(iv) 0.55 mm thick sq.m. 17.46


8.1.36 Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley
/ Gutter / Flashing) at all levels including fitting and fixing self drilling, self
tapping screws complete.TATA Blue scope/Dyna roof / Wonder Roof or
equivalent as directed by the Deptt.
(iv) 0.55 mm thick RM 3.9
9.4.1 Providing barge board of size 200mm x 20mm with 1st class local Hollock/
Bonsum timber including fitting and fixing with necessary wood screws etc.
complete. r.m. 17.00

4.1.8 1st class brick nogged wall in cement mortar including racking out joints and
curing complete as directed in super structure above plinth up to 1st floor
level (protruding M.S rod/Tor steel of column to be embeded in cement
mortar and will be measured and paid separately)

(A) 112 mm thick brick wall


(a). In cement mortar in proportion 1:4 (1 cement:4 sand)
sq.m. 32.49

5.1.6 40 mm thick red oxide floor with under layer of 30 mm thick cement concrete
in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of size 20 mm and
down) and top layer of 10mm thick plaster of cement red-oxide of iron per 50
kg of cement in prop. 1:3 (1 cement red oxide: 3 coarse sand) finished with a
floating coat of neat cement red oxide mix of same proportion. sq.m. 9.00

9.1.2 Providing wood work in frame (chowk aths) of doors, windows, clerestory
windows and other similar works wrought, framed and fixed in position in
contact with C.C or brick masonry wall including supplying, fitting and fixing
with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement
concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the
timber faces in contact with C.C and masonry as directed and specified.

cu.m
0.11
(b). With 1st class timber (Hollock/ Sundi) .
6.2.1 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls
for interior plastering up to 1st floor level including arises or rounded angles
not exceeding 80mm girth and finished even and smooth including curing
complete as directed.

(b). In cement mortar 1:4 sq.m. 72.82


10.2 Providing, fitting and fixing M.S. grill of requiredpattern for windows/
clerestory windows/ openingwith M.S. flats at required spacing in frame all
round, squre or round M.S. bars with round headed bolts and nuts or
screws.

I . Plain grill
(a). Fixed to wooden frames kg 36.00
9.9.5 Providing fitting and fixing 1st class local wood battened and framed door
and window shutters including oxidised iron butt hinges (100mmx 58mmx
1.90mm) 6 nos with necessay screws.

(a) Using Bonsum / Holock wood sq.m. 4.71


13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm
in girth/width after and including preparing the surface by throughly cleaning
oil, grease, dirt snd other foreign matter , sand papering and knotting.

(b). With ready mixed paint , wood primer (white). sq.m. 26.29
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based
surface with enamel paint of approved brand and manufacture (Asian paint/
Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including
cleaning the surfaces of all dirt, dust and other foreign matter sand papering
and stopping.

(i).Surfaces over 100mm in width or girth.


a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/
Nerolac). sq.m. 26.29

Applying primary coat over new steel and other metal surface over 100m in
13.7.2 width or girth after preparing the surface by throughly cleaning oil,grease, dirt
and other foreign matter and scoured with wire brushes, fine steels, wood
scrapers and sand paper.

a). With ready mixed "red-lead/ red oxide" primer. sq.m. 4.80
13.7.4 Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint of approved brand and manufacture(Asian paint/
Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including
cleaning the surface of all dirt, dust and other foreign matter.

(i).Surfaces over 100mm in width or girth.


a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/
Nerolac). sq.m. 4.80

13.9.1 Finishing old / new wall with water proofing weather coat smooth anti-fungal
exterior painting of approved make of Berger paint of required shade after
cleaning and clearing the surface etc. including scaffolding complete as
directed at all levels (two coats) sq.m. 72.82

15.1.1 Supplying, fitting, fixing electrocoloured iron fittings of approved make,


resonably smooth, free from sharp edges and corners, flaws and other defects
and with counter sunk holes for wood screws including necessary screws etc.
complete.

a) Sliding door bolt


ii) 250mm x 16mm each 1
b) Cast iron stove enamelled black door handle
iii) 150mm each 6
c) Tower bolt
iv) 150mm x 10mm each 4
e) M.S Gate shutter hook and eye
ii) 100mm each 4
ANNEXURE-9

Name of work- Supply and installation of 3.00 HP Centrifugal Clear water pump
set with necessary fittings.

as per APWD(Elect) SOR 2013-14 & APHE SOR 20015-16


Sl No Item Unit Quantity
39.4.2
(Elect)
3 HP three phase vertical multistage high pressure centrifugal pump set 8
stage (crompton Greaves/ Aquatic/ CRI/ V-Guard/ Calma make) with DOL
starter (crompton greves & contro switch gear /BCH/ L&T/ Simens make )
fully automatic citation.

3.0 H.P. Three Phase Each 1


32.1
(PWD)

Supplying and laying of following size PVC/XLPE insulated and PVC


sheathed 1.1 KV grade solid Aluminium conductor up to 10 Sq mm balance
standard conductor , XLPE Insulated , cores laid up , PVC tape inner
sheathed , Armour (Aluminium for single core up tpo 70 sq. mm balance
aluminium strip , Galvanized for cable up to 2 X 10 sq.mm , 4 x 6 sq.mm
balance all galvanized steel strip ..................... sand cushioning etc. complete
handling of surplus spoil, debries to proper place as specified and directed by
the Deptt. (Nicco / Havells/ RPG/ CCI/ Polycab/ Gloster/ Finolex make or
equivalent)

32.1.1 2 Core A2 XWaY A2XFaY


32.1.1.1 b) 4.0 sq mm core UG cable RM 20
9.2.4
Labour charge for carrying laying and fixing G.I. pipes complete with
G.I. fittings specials with jointing materials and supplying the jointing
materials all complete as directed excluding trenching and refilling of
earth (external work).

a) 80 mm dia RM 20
9.11.1
Labour charge for cutting and threading G.I. pipes with requird size of
thread including finishing the end all complete as directed.

Qnty=3.14 x 80 x 3 =753.60 mm
mm of dia 753.60
Cost of Materials
5.1
50 mm dia G.I pipe Rm 20.00
6.2.1 50 mm dia G.I socket
6
Each
6.2.2
65 mm dia G.I union socket Each 3
6.2.4 50 mm dia G.I Bend
4
Each
6.2.3 50 mm dia G.I Flange
2
Each
6.2.5
100 mm dia G.I Elbow Each 7
50 mm dia G/M Full wayvalve
2
Each
2.3
Nuts & Bolts 65 mm dia Each 25

3 mm rubber insertion sheet


2.2
65 mm dia Each 15
ANNEXURE-10

Name of Work= Detail estimate for supplying , fitting,fixing 65 mm dia Clear water
pumping main of PUB DATTA KUCHI PWSS

As per APHE schedule of rates for the year of 2015-16


Sch Particulars
Unit Qnty
no
9.1.1
Earth work in excavation in foundation trenches including refilling the
quantity as necessary after completion of works of pipe line dressing,
ramming, watering etc. and removal of surplus earth with 50 m lead and lift
up to 1.5 m all complete including dewatering as directed including bailing
out water where necessary.

1 x 15.00 m x 0.60m x 1.00m=9.00 Cu.M


(a) In ordinary soil cu.m. 9.00
9.2.4
Labour charge for carrying laying and fixing G.I. pipes complete with G.I.
fittings specials with jointing materials and supplying the jointing materials
all complete as directed excluding trenching and refilling of earth (external
work).

65 mm dia
RM 45.00
9.6.4
Labour charge for carrying providing and fixing full way wheel valve of
approved quality with supplying jointing materials all complete as directed.

65 mm dia
Each 1
Cost of Materials
5.1 65 mm dia G.I pipe RM 45.00
6.2.1 65 mm dia G.I socket Each 22
6.2.2 65mm dia G.I union socket Each 3
6.2.4 65 mm dia G.I Bend Each 4
6.2.3 65 mm dia G.I Threaded Flange Each 2
6.2.5 65 mm dia G.I Elbow Each 4
6.2.6
80 mm x 65 mm G.I Reducing socket Each 2
6.2.21 65 mm dia (225 mm long) G.I Nipple Each 2
63 mm dia full way valve Each 1
2.3 Nuts & Bolts 65 mm dia Each 60
2.2 3 mm rubber insertion sheet
65 mm dia Each 35

ANNEXURE-11

Construction of 100 Cu.M Capacity OHR for PUB DATTAKUCHI PWSS with 16 m
Staging

APWD Quatti
Item description Unit
Item No ty

2 3 4 6.00
EARTHWORK IN EXCAVATION
1.1 Earthwork in excavation for foundation trenches of walls, retaining walls,
footings of column, steps, septic tank etc. including refilling (return filling) the
quantity as necessary after completion of work, breaking clods in return filling,
dressing, watering and ramming etc. and removal of surplus earth with all lead
and lifts as directed and specified in the following classification of soils
including bailing out water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.


m. 121.68
(B) Extra over item no.1.1(A) above for each 1m depth or part thereof beyond the
initial depth of 2m cu.
60.84
m.
1.2 Shuttering and shoring the earth at different levels in foundations where
necessary with required prop, struts, planks, timbers, nails etc. including
dewatering if necessary, complete as directed and specified (measurement to be
taken in the face area timbered)

(A) Upto a depth of 1.5 metre sq.


m. 91.26
(B) Above 1.5 m upto 3.00 m depth sq.
m. 91.26
4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing
the subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(b).Brick on edge soling sq.


m. 9.25
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using Cu
9.25
mixture machine) m
2.2.1 Providing and laying plain/reinforced cement croncrete works cement with
coarse sand & 20mm down graded stone aggregate including dewatering if
necessary, and curing complete but excluding cost of form work and
reinforcement for reinforced cement concrete work (form work and
reinforcement will be measured and paid separately)

(I) Using mixture machine


(A) In sub - structure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base
slab, retaining walls, walls of septic tank, inspection pit and the like and other
works not less than 100mm thick up to plinth level.

N) Without using admixture, plasticiser


(d) M30 grade concrete Cu
m 40.26
(B) Super-structure from plinth level upto 1st floor level.

(i) Walls (thickness not less than 100mm) including attached pillasters, buttresses,
plinth and string course etc.

N) Without using admixture, plasticiser


(d) M30 grade concrete Cu
m
Extra over item no.2.2.1(I) (B) above for each subsequent floor or part thereof
above the 1st floor level. Cu
m

Ist lift 6.60m + 2nd lift 9.90m + 3rd lift 12.90m= (314.43x3) = 943.29 = Cu
(6855.86+943.29) 14.55
m
(ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and
support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase
(except spiral staircase and landing ) including preparing the top surface and
finishing of nosing.

N) Without using admixture, plasticiser


(d) M30 grade concrete
Up to Height 3.30 m Cu
m 13.02
Cu
Height from 3.30m to 6.60m m
2.2.3 Extra over item no.2.2.1(I) (B) above for each subsequent floor or part thereof
above the 1st floor level. Cu
m

Ist lift 3.30m to 6.60m = 314.43+6945.94=7260.37 Cu


13.02
m
Height from 6.60m to 9.90m
Extra over item no.2.2.1(I) (B) above for each subsequent floor or part thereof
above the 1st floor level. Cu
m

Ist lift 9.90m + 2nd lift 9.90m = (314.43x2) = 612.38+6945.94 Cu


13.02
m
Height from 9.90m to 12.20m
Extra over item no.2.2.1(I) (B) above for each subsequent floor or part thereof
above the 1st floor level.

2nd lift 9.90m + 2nd lift 12.20m = (314.43x3) =942.00= Cu


6945++942.00=7889.23 22.08
m
Height from 12.20m to 15.6m
3rd lift 12.20 m + 4th lift 15.6 m = (314.43x4) = 1256.00= Cu
(6945.94+1256.00)=8201.94 14.49
m
22.2.7 Extra for providing and mixing waterproofing Plastisizer Plastocrete Plus of
Sika India Ltd /Dr. Sealkit LW Super (Asian Chemicals)/ RHEOMAC 730 of
BASF @ 200gms per bag of cement in concrete for waterproofing as specified
and directed by the Department complete at all levels.

Cu
(iii) 1 : 1 : 2 (1cement : 1coarse sand : 2aggregate) or M-25 grade. 130.43
m
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of propping
and centering below supporting floor to ceiling not exceeding 4.0M and
removal of the same for in-situ reinforced concrete and plain concrete work in:

3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works
etc.
(i) Using 38mm thick plank sq.
m. 89.88
3.1.1.3 Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having
plane vertical face
(i) Using 38mm thick plank
sq.
Column up to height 3.20m m. 93.48
sq.
51.20
Column height from 3.20m to 6.40m m.
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b). sq.
51.20
m.

sq.
51.20
Column height from 6.40m to 9.60m m.
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Extra rate =( 23.19 X2)=46.38 sq.


51.20
m.
sq.
51.20
Column height from 9.60m to 12.80m m.
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Extra rate =( 23.19 X3)=69.57 sq.


51.20
m.
Column height from 12.80m to 16.0 m sq. 51.20
m.
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Extra rate =( 23.19 X4)= 92.76 sq.


51.20
m.
sq.
48.00
Column height from 16.0m to 19.0 m m.
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Extra rate =( 23.19 X5)= 115.95 sq.


48.00
m.
3.1.1.4 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers,
lintels and horizontal ties.

(a) For depth not exceeding 1.0M.


(i) Using 38mm thick plank
I st breasing beam sq.
m. 28.68
2 nd breasing beam sq.
m. 54.81
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Extra lift up to 2 nd Bracing beam sq.


54.81
m.
3rd breasing beam sq.
m. 54.81
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Extra lift up to 3 nd Bracing beam=(Rs. 23.19x2) sq.


54.81
m.
4 th breasing beam sq.
m. 54.81
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Extra lift up to 3 nd Bracing beam=(Rs. 23.19x3) sq.


54.81
m.
Rong beam sq.
m. 54.81
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Extra lift up to 3 nd Bracing beam (Rs. 23.19x4) sq.


54.81
m.
Top beam sq.
m. 35.91
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Extra lift up to 3 nd Bracing beam (Rs. 23.19x5) sq.


35.91
m.
3.1.1.5 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever
slabs, chajjas, balconies and the like.

(a) Floors etc. upto 200mm in thickness.


(i) Using 38mm thick plank sq.
m. 109.33
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Quantity from 2nd breasing beam to 3 rd Bresing beam =( 23.19 X3)=69.57 sq.
109.33
m.
3.1.1.8 Vertical surface such as walls (any thickness), parapet walls, partitions, walls
of septic tank, inspection pit and the like including attached pilasters, butresses,
plinth and string courses and the like.

(i) Using 38mm thick plank sq.


m. 166.32
3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as
mentioned in item no. 3.1.1 & 3.1.3(b).

Quantity from 2nd breasing beam to 3 rd Bresing beam =( 23.19 X3)=69.57 sq.
166.32
m.
6.2.3 20 mm thick Cement plaster in two coats, on single or half brick walls for
interior plastering up to 1st floor level including arises, internal rounded
angles,chamfers and / or rounded angles not exceeding 80mm in girth and
finished even and smooth including curing complete as directed.

(b). In cement mortar 1:4 sq.


m. 611.57
6.2.4 Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing
materials in cement mortar in prop as recommended by the manufacturer
including curing complete as directed.

6.2.7 (b). In cement mortar 1:4 sq.


611.57
m.
13.9.4 Finishing old/ new wall with water proofing weather coat smooth anti-fungal
premium acrylic smooth exterior finish of Snowcryl XT brand of Snowcem
India Ltd. of required shade after clering and clearing the surfaces etc.
including scaffolding complete as directed at all levels (two coats). sq.
472.97
m.

d) Extra over item no. (b) and (c) above for every subsequent coat of water
proofing cement paint of approved brand and manufactured. sq.
472.97
m.

18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to


relevant I.S. Code for R.C.C. work/ R.B. walling including straightening,
cleaning, cutting and bending to proper shapes and length as per details,
supplying and binding with 20G annealed black wire and placing in position
with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor
level).

a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL

(i) TMT corrosion resistant steel (CRS) qtl 176.86


18.1.2 Extra over Item 18.1.1 (a,b,c) for each subsequent floor or part thereof above
first floor level. qtl 88.39

19.2 Providing plinth protection with bricks flat laid in cement mortar 1: 4 and
finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of sq.
neat cement finish. 83.93
m.

10.2
Providing, fitting and fixing M.S. grill of requiredpattern for windows/
clerestory windows/ openingwith M.S. flats at required spacing in frame all
round, squre or round M.S. bars with round headed bolts and nuts or
screws.
II Ornamental grill
(c). Fixed to Brickwork/P.C.C/R.C.C. Kg 170.09
18.6 ANGLES/ FLATS/ BOLTS AND NUTS
18.6.1 Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts
including painting with red lead paint one coat complete as directed.

a) M. S. Angles……. qtl 13.52

CI D/F SLUICE VALVE WITH CAP/ WHEEL AS PER IS 14846/2000


6.3.15
PN 1.0 WITH ISI MARKING

150 mm dia Sluice Valve Eac 1.00


h
Eac
100 mm dia Sluice Valve
h 1.00

CAST IRON NON-RETURN VALVE FLANGED TYPE (ZOLOTO or


6.3.8 Equivalent) Conforming to IS:5312:1984 Part-I Swing type with Natural
Rubber Flap, Flanges Drilled to IS:1538 PN-1.0

Eac
100mm dia
h 1.00
6.3.12 C.I. Double Air Release Valve as per IS : 14845/2000
Eac
100mm dia
h 1.00
Eac
150mm dia
h 1.00
9.6.1
Labour charge for carrying, placing in position, fitting and fixing C.I.
sluice valve (with wheel & cap) C.I. reflex valve complete with
supplying bolts and nuts, 3 mm thick rubber insertion sheet etc. (the tail
pieces if required will be paid separately) all complete as directed (one
valve and two flanged joints).

Eac
100 mm dia
h 2.00
Eac
150 mm dia
h 1.00
Analysis Construction of brick masonary valve chamber with 23 cm 1 st class brick in
prop. 1:4 finished with 10 mm thick cement plastering prop. 1 :4 inside wall in
floor including necessary earth work in excavation and refilling the sides of the
same after completion of brick work. The size of chamber 60cm x 60cm x 120
cm inside with a RCC cover slab in 10 tor T.S @150 mm c/c both ways
binding with black wire. Brick flat soling with 1:3:6 in the base of chamber
complete as per specification and drawing approved by the Deptt.

Eac
h 3.00
Analysis Providing bamboo scaffolding wirth Jati and Bhaluka Bamboo adequately
strengthened to withstand the weight of the structure and live load at different
stages of work including cost of ropes, planks, nails etc all complete.

3649.2
Job 1
PHE Supply, erection, jointing, testing & commi- ssioning of different dia. G.I. pipe
e.s in inlet, Delivery, Overflow and Wash Pipes for the ESR with all nuts,
bolts, gaskets and painting etc. all complete as directed and specified.

a) In CWPM (Inlet Pipe)


b) Delivery Pipe
150 mm dia. G.I Pipe @ Rs 1381.70 + 25% cost oflabour=Rs1727.10
RM 20.50

c) Overflow & Backwash pipe Pipe


150 mm dia. G.I Pipe @ Rs 1381.70 + 25% cost oflabour=Rs1727.10
RM 19.50

D) Waste water pipe


100 mm dia. D.I Pipe @ Rs 888.90 + 25% cost of labour=Rs 1111.10
RM 30.50

Materials
6.2.5 150 mm dia G.I Elbow Eac
6.00
h
100 mm dia G.I Elbow Eac
2.00
h
6.2.4 150 mm dia GI Bend Eac
4.00
h
100 mm dia G.I Bend Eac
2.00
h
6.2.1 150 mm dia G.I Socket Eac
8.00
h
100 mm dia G.I Socket Eac
4.00
h
6.2.3 150 mm dia G.I Flange Eac
8.00
h
100 mm dia G.I Flange Eac
4.00
h
19.5 Providing drain with brick work in cement mortar in proportion 1:5 with half
brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat
soling including 15mm thick cement plastering in prop. 1:3 finished with a
floating coat of cement slurry as directed with necessary shttering for sides and
earth work in excavation of foundation trenches and refilling the sides after
completion of work etc. as specified.

ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial 42.269
depth of 100mm. r.m.
8
1.46(sa Providing fitting and fixing 450 mm dia . 90 mm thick C.I Man hole cover and
ni) frame of 58 kg. weight complete as directed and specified. Eac
1.00
h
Providing, supplying and placing of GI water stopper in RCC wall, base slab,
cover slab,
CPHE Approved central shaft etc. of water retaining
structureto be made out of G.I. plain sheet
not thinner than 22 SWg and of size 300 mm
wide, all complete as directed and RM 100.80
specified. (for the Cascade type Aerator, it
is to be provided at the junction of the deck
slab and the gutter wall.)

Supplying, fitting and fixing of 80 mm. dia.G.I. (M) air vent pipe in under
ground sump,of length 450 mm. and with flanges at bothends, one being
CPHE Approved

embedded in concrete and theother fixed with mosquito proof wire mesh (the
wire mesh being facing the floor of the sump) with necessary nuts & bolts etc.,
all complete as directed and specified. Eac
1.00
h
CPHE Approved CPHE Approved

Float operated water level indicator for the reservor having the range of 0-50
m3 with least count of 5 m3 complete with float , scale , pully , nylon chord,
M.S frame etc. and including calibration of the scale, all complete as directed.
Eac
h 1.00

Supplying fitting and fixing of lightening aerestor system at roof of the


reservoir including conductor strip and 2 nos plate earth station etc. complete
as directed and specified.
Eac
h 1.00

-------------------------------
ANNEXURE-12A

Nme of work= Laying of distribution network of PUB DATTA KUCHIPWSS


Sch Quantit
Item Of work Unit
no y
9.1.1

Earth work in excavation in foundation trenches including refilling


the quantity as necessary after completion of works of pipe line
dressing, ramming, watering etc. and removal of surplus earth with
50 m lead and lift up to 1.5 m all complete including dewatering as
directed including bailing out water where necessary.

(a) Ordinary soil


For pipeline Cu M 3495.00
9.2.7

Labour charge for carrying and laying in position in trenches P.V.C/


pipes with specials in lines and level including cutting the pipes
where necessary and providing joints to pipes and specials with
jointing materials such as cement lubricant after roughening the
surfaces including the cost of jointing materials and testing the joints
all complete as directed

75 mm dia ,, 4680.00
90 mm dia ,, 745.00
110mm dia ,, 1565.00
9.2.4
Labour charge for carrying laying and fixing G.I. pipes complete
with G.I. fittings specials with jointing materials and supplying the
jointing materials all complete as directed excluding trenching and
refilling of earth (external work).

100mm dia RM 20.00


80mm dia RM 26.00
65mm dia RM 30.00
50mm dia RM 30.00
Analysi Construction of brick masonary valve chamber with 23 cm 1 st class brick
s in prop. 1:4 finished with 10 mm thick cement plastering prop. 1 :4 inside
wall in floor including necessary earth work in excavation and refilling the
sides of the same after completion of brick work. The size of chamber
60cm x 60cm x 120 cm inside with a RCC cover slab in 10 tor T.S @150
mm c/c both ways binding with black wire. Brick flat soling with 1:3:6 in
the base of chamber complete as per specification and drawing approved by
the Deptt.

Each 11
9.6.1
Labour charge for carrying, placing in position, fitting and fixing C.I.
sluice valve (with wheel & cap) C.I. reflex valve complete with
supplying bolts and nuts, 3 mm thick rubber insertion sheet etc. (the
tail pieces if required will be paid separately) all complete as directed
(one valve and two flanged joints).

80 mm dia Each 6
100 mm dia Each 3
9.6.6
Labour charge for carrying, fitting and fixing C.I. double air valve
complete with supplying bolts, nuts 3 mm thick rubber insertion etc.
all complete as directed.
a) 80 mm dia Each 2
9.13.1

Construction of platform of hydrant pillar with average 60 mm thick


cement concrete in proportion 1:2:4 of size 1.45 m x 1.45 m (outside
to outside) ...... plastering in proportion 1:3 to exposed surface,
finished with neat cement and curing complete as per approved
drawing of CPHE 08/05 including necessary earthwork and refilling
after completion of work as specified and directed.

Each 4
9.13.2

Construction of R.C.C. hydrant pillar of size 13 cm x 13 cm x 165


cm high (75 cm below G.L. & 90 cm above G.L.) in prop. 1:2:4
reinforced with 4 Nos. of 10 mm dia HYSD bars and 6 mm dia MS
tie bars @ 150 mm C/C including cutting, bending and placing in
position and binding with ....cement plastering in prop. 1:4 to Each 3
exposed surface finished with neat cement coat as per approved
drawing of CPHE 08/05 including necessary earthwork etc. all
complete as directed. (Hydrant pillar is to be constructed along with
the platform at a time where it is necessary)

7.3.1 Construction of drain with cement concrete works in proportion 1:2:4


in slope 1:50 with a base layer of concrete of proportion 1:4:8 as per
respective approved drawings including necessary earth work and
refilling after completion of work all complete as directed.

Total Length= 4 nos x 1.50m=33.00 Metre 6.0


ANNEXURE-12B

Brick masonary valve chamber inside clear area 900 mm x 900 mm x 1250 mm
including precast slab over the chamber
Sch Particulars Qnt
Unit
no y
1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of
column, steps, septic tank etc. including refilling (return filling) the quantity as
necessary after completion of work, breaking clods in return filling, dressing,
watering and ramming etc. and removal of surplus earth with all lead and lifts as
directed and specified in the following classification of soils including bailing out
water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

Qnty= 1 x 1.55m x 1.55 m x 1.40m =3.66cum


(a) In ordinary soil cu.m
. 3.36
4.1.1 Providing brick soling in foundation and under floor with stone/ best quality picked
jhama brick, sand packed and laid to level and in panel after preparing the subgrade
as directed including all labour and materials and if necessary dewatering, complete.

Qnty= 1 x 1.55m x 1.55 m =2.40 Sqm


(a).Brick on flat soling. sq.m
. 2.40
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and specified
including dewatering if necessary, and curing complete (shuttering where necessary
shall be measured and paid separately).

Qnty= 1 x 1.55m x 1.55 m x 0.10m =0.24cum


(b). In prop. 1:4:8 (1 cement:4 coarse sand : 8 coarse agg. by volume (using mixture 0.24
machine) Cum
0
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and
dewatering if necessary, and curing complete as directed
(I) In sub-structure up to plinth level including dewatering if necessary

Qnty=
1 x 2 x 1.40 x 0.25 x 1.15 =0.81 Cum
1 x 2 x 0.90 x 0.25 x 1.15 =0.52 Cum
1 x 2 x 1.40 x 0.112 x 0.10 =0.03 Cum
1 x 2 x 0.90 x 0.112 x 0.10 =0.02 Cum

Total=1.38 Cum
(c). In proportion 1:5. cu.m
1.38
.
6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall for interior
plastering up to 1st floor level including arises, internal rounded angles, not
exceeding 80mm girth and finished even and smooth including curing complete as
directed.

A) On rough side
Qnty= For inside plastering
1 x 4 x 0.90 x 1.25 = 4.50 Sqm
(b). In cement mortar 1:4 sq.m
. 4.50
B) On fair side
Qnty For outside plastering
1 x 4 x 1.40 x 0.15 = 0.84 Sqm
(b). In cement mortar 1:4 sq.m
. 0.84
25.1 Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced
2 with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black
annealed wire with necessary shuttering , curing etc. complete including fixing in
position as directed.

1 x 1 x 1.12 x 1.12 = 1.25 Sqm


b) 100 mm thick slab sq.m
. 1.25
ANNEXURE-12C

MATERIALS REQUIRED FOR THE DISTRIBUTION NETWORK

As per CPHE schedule of rates for the year 2015-16

Sl No Particulars of materials Unit Qty


5.4 PVC Pipe
110 mm dia P.V.C pipe R.M 1565.00
90 mm dia P.V.C pipe R.M 745.00
75 mm dia P.V.C pipe R.M 4680.00
G.I.Pipe
5.1 G.I. Pipes (Medium Class)
50 mm dia R.M 30.00
65 mm dia R.M 30.00
80 mm dia R.M 26.00
100 mm dia R.M 20.00
6.1.1 UP.V.C Coupler ( Socket )
110 mm dia Each 261
90 mm dia Each 124
75 mm dia Each 780
6.1.2 UPVC Male Threaded Adaptor
110 mm dia Each 3
90 mm dia Each 6
75 mm dia Each 7
6.1.2 UPVC Female Threaded Adaptor
110 mm dia Each 3
90 mm dia Each 6
75 mm dia Each 7
6.1.14 UP.V.C. reducing Tee
110 mm x 90 mm dia Each 3
110 mm x 75 mm dia Each 3
90 mm x 75 mm dia Each 4
6.1.15 UP.V.C. reducing Bush
110 mm x 90 mm dia Each 3
110 mm x 75 mm dia Each 2
90 mm x 75 mm dia Each 4
6.1.16 UP.V.C. reducing Socket
110 mm x 90 mm dia Each 5
110 mm x 75 mm dia Each 4
90 mm x 75 mm dia Each 5
6.1.10 UP.V.C tailpiece
110 mm dia Each 3
90 mm dia Each 6
75 mm dia Each 7
6.1.12 U.P.V.C Bend (90)"
110 mm dia Each 22
90 mm dia Each 30
75 mm dia Each 39
6.1.18 U.P.V.C End cap threaded
110 mm dia Each 5
90 mm dia Each 5
75 mm dia Each 6
6.1.4 UP.V.C Elbow
110 mm dia Each 20
90 mm dia Each 25
75 mm dia Each 38
6.1.15 UP.V.C equal tee
110 mm dia Each 2
90 mm dia Each 2
75 mm dia Each 3
K UP.V.C Flange
110 mm dia Each 3
90 mm dia Each 3
75 mm dia Each 5
63 mm dia Each 5
6.1.11 G.I Socket
100 mm dia Each 5
80 mm dia Each 6
65 mm dia Each 7
50 mm dia Each 7
6.2.2 G.I Union Socket
80 mm dia Each 7
65 mm dia Each 8
50 mm dia Each 10
6.2.3 G.I Threaded flange
100 mm dia Each 6
80 mm dia Each 8
65 mm dia Each 11
50 mm dia Each 12
6.2.4 G.I Bend
100 mm dia Each 12
80 mm dia Each 15
65 mm dia Each 18
50 mm dia Each 22
6.2.5 G.I Elbow
100 mm dia Each 5
80 mm dia Each 6
65 mm dia Each 6
50 mm dia Each 10
6.2.6 G.I Reducing Socket
100 X 80 mm dia Each 2
80 X 65 mm dia Each 6
65 X 50 mm dia Each 6
6.2.18 G.I Nipple 150 mm long
100 mm dia Each 5
80 mm dia Each 3
65 mm dia Each 3
50 mm dia Each 5
6.2.21 G.I Nipple 225 mm long
100 mm dia Each 6
80 mm dia Each 6
65 mm dia Each 7
50 mm dia Each 7
6.3.15 C.I D.F sluice valve
100 mm dia Each 3
80 mm dia Each 6
6.3.12 80 mm dia double A/Release Valve Each 2
2.2 3 mm thick rubber insertion (For 35(N))
100 mm dia Each 23
80 mm dia Each 24
2.3 Bolts & Nuts (For 35(N))
100 mm dia Each 44
80 mm dia Each 43
6.1.9 UPVC Service Saddle Piece Each
90 mm dia Each 8
75 mm dia Each 15
63 mm dia Each 20
6.3.4 Bronze Ferrule Cock (Medium) (Zoloto or Equivalent)
15 mm dia Each 10
ANNEXURE-12D

Road crossing by horizontal boringof Distribution pipe network of PUB DATTA


KUCHI PWSS

Rate as per APHE SOR 2015-16

Sl No Item of Works Unit Quantity


Cost Of Labour
10.5.1
Labour charge for making bore hole horizontally across
road or embankment for crossing distribution pipe line
including fitting fixing of G.I. casing pipe of required dia
excluding the cost of pipe all complete as directed by the
deptt.

150 mm dia RM 9.5


A.Cost of Materials
5.1
i) 150 mm dia G.I pipe for casing RM 9.5
2.1 3
ii) Bhaluka Bamboo Each
2.1 4
iii) Coconut Rope Kg
iv) Tools & Plants L/S L/S

Total Nos of Road Crossing=8nos.


ANNEXURE-12E

Construction of R.C.C.supporting pillar at low laying area of Distribution network


of PUB DATTA KUCHI PWSS.

As per A.P. W.D (build) schedule of rates for the year 2013-14
Sch
no Description of Item Unit Quantity
1.1 Earthwork in excavation for foundation trenches of walls, retaining walls,
footings of column, steps, septic tank etc. including refilling (return filling) the
quantity as necessary after completion of work, breaking clods in return
filling, dressing, watering and ramming etc. and removal of surplus earth with
all lead and lifts as directed and specified in the following classification of
soils including bailing out water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.m. 9.72


1.2 Shuttering and shoring the earth at different levels in foundations where
necessary with required prop, struts, planks, timbers, nails etc. including
dewatering if necessary, complete as directed and specified (measurement to
be taken in the face area timbered)

(A) Upto a depth of 1.5 metre sq.m. 36.00


2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using
mixture machine) Cum 0.61
4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing
the subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(a).Brick on flat soling. sq.m. 8.10


18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to
relevant I.S. Code for R.C.C. work/ R.B. walling including straightening,
cleaning, cutting and bending to proper shapes and length as per details,
supplying and binding with 20G annealed black wire and placing in position
with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor
level).

b) a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL

(i) TMT corrosion resistant steel (CRS) qtl 2.99


3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of propping
and centering below supporting floor to ceiling not exceeding 4.0M and
removal of the same for in-situ reinforced concrete and plain concrete work in:

3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works
etc.
(i) Using 38mm thick plank sq.m. 29.00
2.2.1 Providing and laying plain/reinforced cement croncrete works cement with
coarse sand & 20mm down graded stone aggregate including dewatering if
necessary, and curing complete but excluding cost of form work and
reinforcement for reinforced cement concrete work (form work and
reinforcement will be measured and paid separately)

(I) Using mixture machine


(A) In sub - structure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base
slab, retaining walls, walls of septic tank, inspection pit and the like and other
works not less than 100mm thick up to plinth level.

M25 grade concrete Cum 2.14


6.2.1 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls
for interior plastering up to 1st floor level including arises or rounded angles
not exceeding 80mm girth and finished even and smooth including curing
complete as directed.

(b). In cement mortar 1:4 sq.m. 18.41


ANNEXURE-13

Name of work- Construction of Raw water Pump House cum Duty room PUB
DATTA KUCHIP.W.S.S

As per A.P. W.D (build) schedule of rates for the year 2013-14
Sch
No Description of Item Unit Quantity
1.1 Earthwork in excavation for foundation trenches of walls, retaining walls,
footings of column, steps, septic tank etc. including refilling (return filling) the
quantity as necessary after completion of work, breaking clods in return
filling, dressing, watering and ramming etc. and removal of surplus earth with
all lead and lifts as directed and specified in the following classification of
soils including bailing out water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.m. 1.62


2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using
mixture machine) Cum 0.32
4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing
the subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(a).Brick on flat soling. sq.m. 10.44


18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to
relevant I.S. Code for R.C.C. work/ R.B. walling including straightening,
cleaning, cutting and bending to proper shapes and length as per details,
supplying and binding with 20G annealed black wire and placing in position
with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor
level).

a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL

(i) TMT corrosion resistant steel (CRS) qtl 3.94


c) ISI approved mild steel reinforcement bar (M.S. Bar) qtl 0.86
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of propping
and centering below supporting floor to ceiling not exceeding 4.0M and
removal of the same for in-situ reinforced concrete and plain concrete work in:

3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works
etc.
(ii) Using 25mm thick plank sq.m. 5.40
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having
plane vertical face
(ii) Using 25mm thick plank sq.m. 10.26
3.1.1.5 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever
slabs, chajjas, balconies and the like.

(a) Floors etc. upto 200mm in thickness.


(ii) Using 25mm thick plank sq.m. 26.76
2.1.3 Providing and laying 25mm thick damp proof course with cement concrete in
prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including
providing approved damp proof admixture in proportion as recommended by
the manufacturer including curing etc. complete as directed. Sqm 2.16
2.2.1 Providing and laying plain/reinforced cement croncrete works cement with
coarse sand & 20mm down graded stone aggregate including dewatering if
necessary, and curing complete but excluding cost of form work and
reinforcement for reinforced cement concrete work (form work and
reinforcement will be measured and paid separately)

(I) Using mixture machine


(A) In sub - structure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base
slab, retaining walls, walls of septic tank, inspection pit and the like and other
works not less than 100mm thick up to plinth level.

P) Using admixture, plasticiser etc for air entraining, water reducing purposes
including addition of agent for changing normal setting time of concrete as
required.

(b) M20 grade concret or Prop. 1:1.5:3 Cum 0.65


(B) Super-structure from plinth level upto 1st floor level.
(ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and
support, balcony, lintel, sill band, beam, girder, bressumer, cantilever,
staircase (except spiral staircase and landing ) including preparing the top
surface and finishing of nosing.

P) Using admixture, plasticiser etc


(b) M20 grade concret or Prop. 1:1.5:3 Cum 2.19
18.3.1 Providing fitting, hoisting and fixing of roof trusses including purlins
fabricated out of M.S. circular hollow section conforming to relevant I.S.
code, as per approved design and drawings including providing M.S. cleats,
base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer
and two coats of approved enamel paints complete including fitting necessary
cleats etc. for fixing ceiling joists as per design and drawing as directed.

a) TATA make Circular hollow section - CHS of grade YST-310 conforming


to I:S Specification : 1161-1998 qtl 3.43
8.1.35 Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels
including fitting and fixing self drilling, self tapping screws complete (Roof
trusses, purlins etc. to be measured and paid separately.) .TATA Blue
scope/Dyna roof / Wonder Roof or equivalent as directed by the Deptt.

(iv) 0.55 mm thick sq.m. 21.86


8.1.35 Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels
including fitting and fixing self drilling, self tapping screws complete (Roof
trusses, purlins etc. to be measured and paid separately.) .TATA Blue
scope/Dyna roof / Wonder Roof or equivalent as directed by the Deptt.

(iv) 0.55 mm thick sq.m. 21.86


8.1.36 Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley /
Gutter / Flashing) at all levels including fitting and fixing self drilling, self
tapping screws complete.TATA Blue scope/Dyna roof / Wonder Roof or
equivalent as directed by the Deptt.

(iv) 0.55 mm thick RM 13.3


9.4.1 Providing barge board of size 200mm x 20mm with 1st class local Hollock/
Bonsum timber including fitting and fixing with necessary wood screws etc.
complete. r.m. 26.40

5.1.10 Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse
sand) finished with a floating coat of neat cement including rounding of
junctions with floor.

(a) 15 mm thick sq.m. 2.20


4.1.4 Brick work in cement morter with 1st class brick including racking out joints
and dewatering if necessary, and curing complete as directed

(I) In sub-structure up to plinth level including dewatering if necessary

(b). In proportion 1:4. cu.m. 2.15


4.1.8 1st class brick nogged wall in cement mortar including racking out joints and
curing complete as directed in super structure above plinth up to 1st floor level
(protruding M.S rod/Tor steel of column to be embeded in cement mortar and
will be measured and paid separately)
(A) 112 mm thick brick wall
(a). In cement mortar in proportion 1:4 (1 cement:4 sand)
sq.m. 30.51

5.1.8 Providing and laying 65mm thick C.C. floor with metallic concrete hardener
topping under layer of 50 mm thick cement concrete 1:2:4 (1cement:2 coarse
sand:4 coarse aggregate of 20 mm and down) and top layer of 15mm thick of
metallic cement hardener consisting of mix 1:2 (1 cement hardener mix : 2
stone aggregate 6 mm and down) by volume with which metallic hardening
compound of approved quality is mixed in the ratio of 4:1 (4 parts of cement:
1 part of metallic floor hardening compound of approved quality by weight)
including finishing with curing complete as directed. sq.m. 15.60

9.1.2 Providing wood work in frame (chowk aths) of doors, windows, clerestory
windows and other similar works wrought, framed and fixed in position in
contact with C.C or brick masonry wall including supplying, fitting and fixing
with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement
concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the
timber faces in contact with C.C and masonry as directed and specified.

(b). With 1st class timber (Hollock/ Sundi) cu.m. 0.11


6.2.1 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls
for interior plastering up to 1st floor level including arises or rounded angles
not exceeding 80mm girth and finished even and smooth including curing
complete as directed.

(b). In cement mortar 1:4 sq.m. 97.26


10.2 Providing, fitting and fixing M.S. grill of requiredpattern for windows/
clerestory windows/ openingwith M.S. flats at required spacing in frame all
round, squre or round M.S. bars with round headed bolts and nuts or
screws.

I . Plain grill
(a). Fixed to wooden frames kg 36.00
9.9.5 Providing fitting and fixing 1st class local wood battened and framed door
and window shutters including oxidised iron butt hinges (100mmx 58mmx
1.90mm) 6 nos with necessay screws.

(a) Using Bonsum / Holock wood sq.m. 4.71


13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm
in girth/width after and including preparing the surface by throughly cleaning
oil, grease, dirt snd other foreign matter , sand papering and knotting.

(b). With ready mixed paint , wood primer (white). sq.m. 26.29
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based
surface with enamel paint of approved brand and manufacture (Asian paint/
Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including
cleaning the surfaces of all dirt, dust and other foreign matter sand papering
and stopping.

(i).Surfaces over 100mm in width or girth.


a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/
Nerolac). sq.m. 26.29

13.7.2 Applying primary coat over new steel and other metal surface over 100m in
width or girth after preparing the surface by throughly cleaning oil,grease, dirt
and other foreign matter and scoured with wire brushes, fine steels, wood
scrapers and sand paper.

a). With ready mixed "red-lead/ red oxide" primer. sq.m. 4.80
13.7.4 Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint of approved brand and manufacture(Asian paint/
Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including
cleaning the surface of all dirt, dust and other foreign matter.

(i).Surfaces over 100mm in width or girth.


a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/
Nerolac). sq.m. 4.80
13.2.2 f) Distempering with dry distemper of approved brand and manufacture(two
coats)and of required shade on new wall surface to give an even shade, over
and including priming coat of white primer after throughly brushing the
surface free from mortar dropings and other foreign matter and including
preparing surface even and sand papered smooth.
sq.m. 97.26

15.1.1 Supplying, fitting, fixing electrocoloured iron fittings of approved make,


resonably smooth, free from sharp edges and corners, flaws and other defects
and with counter sunk holes for wood screws including necessary screws etc.
complete.

a) Sliding door bolt


ii) 250mm x 16mm each 1
b) Cast iron stove enamelled black door handle
iii) 150mm each 6
c) Tower bolt
iv) 150mm x 10mm each 4
e) M.S Gate shutter hook and eye
ii) 100mm each 4
ANNEXURE-14

Name of work- Construction of Accomodation for operating staff of PUB DATTA


KUCHIWater supply Scheme

As per A.P. W.D (build) schedule of rates for the year 2013-14
Sch no Item of work Unit Quantity
1.1 Earthwork in excavation for foundation trenches of walls, retaining walls,
footings of column, steps, septic tank etc. including refilling (return filling)
the quantity as necessary after completion of work, breaking clods in return
filling, dressing, watering and ramming etc. and removal of surplus earth with
all lead and lifts as directed and specified in the following classification of
soils including bailing out water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.m. 3.83


2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using
mixture machine) Cum 1.88
4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing
the subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(a).Brick on flat soling. sq.m. 48.62


18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to
relevant I.S. Code for R.C.C. work/ R.B. walling including straightening,
cleaning, cutting and bending to proper shapes and length as per details,
supplying and binding with 20G annealed black wire and placing in position
with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor
level).

a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL

(i) TMT corrosion resistant steel (CRS) qtl 7.98


c) c) ISI approved mild steel reinforcement bar (M.S. Bar) qtl 1.48
2.1.3 Providing and laying 25mm thick damp proof course with cement concrete in
prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including
providing approved damp proof admixture in proportion as recommended by
the manufacturer including curing etc. complete as directed. Sqm 10.45

3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of propping
and centering below supporting floor to ceiling not exceeding 4.0M and
removal of the same for in-situ reinforced concrete and plain concrete work
in:

3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete
works etc.
(ii) Using 25mm thick plank sq.m. 32.28
3.1.1.3 Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having
plane vertical face
(ii) Using 25mm thick plank sq.m. 25.62
3.1.1.5 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever
slabs, chajjas, balconies and the like.

(ii) Using 25mm thick plank sq.m. 33.18


2.2.1 Providing and laying plain/reinforced cement croncrete works cement with
coarse sand & 20mm down graded stone aggregate including dewatering if
necessary, and curing complete but excluding cost of form work and
reinforcement for reinforced cement concrete work (form work and
reinforcement will be measured and paid separately)

(I) Using mixture machine


(A) In sub - structure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base
slab, retaining walls, walls of septic tank, inspection pit and the like and other
works not less than 100mm thick up to plinth level.

N) Without using admixture, plasticiser


(b) M20 grade concret or Prop. 1:1.5:3 Cum 2.9505
(ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and
support, balcony, lintel, sill band, beam, girder, bressumer, cantilever,
staircase (except spiral staircase and landing ) including preparing the top
surface and finishing of nosing.

N) Without using admixture, plasticiser


(b) M20 grade concret or Prop. 1:1.5:3 Cum 2.6717275
4.1.4 Brick work in cement morter with 1st class brick including racking out joints
and dewatering if necessary, and curing complete as directed

(I) In sub-structure up to plinth level including dewatering if necessary

(b). In proportion 1:4. cu.m. 8.47


4.1.9 112 mm thick reinforced brick wall in prop 1:5 reinforced with two lines of
M.S rod/ Tor steel as specified embeded in 38 mm thick concrete course in
prop.1:2:4 with coarse agg. 12mm down at every fourth courses embeded with
protruding rod in column including curing etc.complete as directed ( M.S
rod/Tor steel shall be measured and paid separately) in super structure above
plinth up to 1st floor level. sq.m. 96.36

4.1.10 75 mm thick reinforced brick wall in prop 1:5 reinforced with one line of M.S
rod/ Tor steel as specified embeded in 28 mm thick concrete course in
prop.1:2:4 with coarse agg. 12mm down at every third course embedded with
protruding rod in column complete as directed (M.S rod / Tor steel shall be
measured and paid separately) in super structure up to 1st floor level.
sq.m. 3.12

6.2.1 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls
for interior plastering up to 1st floor level including arises or rounded angles
not exceeding 80mm girth and finished even and smooth including curing
complete as directed.

(b). In cement mortar 1:4 sq.m. 82.24


6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall for
interior plastering up to 1st floor level including arises, internal rounded
angles, not exceeding 80mm girth and finished even and smooth including
curing complete as directed.

A) On rough side
(b). In cement mortar 1:4 sq.m. 133.53
5.1.4 65 mm thick cement concrete floor consisting of 50 mm under layer of cement
concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm
and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2
(1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in
panels and finished with a floating coat of neat cement finish (using cement
slurry for bond @ 2.75 kg. per square metre of floor area) including curing
sq.m. 29.25
etc. complete as directed.

5.1.10 Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse
sand) finished with a floating coat of neat cement including rounding of
junctions with floor.

(b) 20 mm thick sq.m. 17.83


18.3.2 Providing welding, fitting, fixing, hoisting and fixing of roof trusses with
purlin, bottom runner etc. fabricated out of a combination of two or all of the
following sections: (i) square sections (ii) rectangular hollow section of
specification SHS/RHS and including purlins, bottom runners and providing
MS cleat, MS angle base plank, bolts and nuts with red oxide Zinc Chromate
primer including fitting bottom runner and cleat etc. for fixing ceilling joist as
per design complete as directed as per specifications.

a)Using TATA makeRHS/SHS of gade 310 conforming to I:S Specification :


4923:1997 qtl 7.87
9.4.1 Providing barge board of size 200mm x 20mm with 1st class local Hollock/
Bonsum timber including fitting and fixing with necessary wood screws etc.
complete. r.m. 18.80

9.9.1 Providing fitting and fixing 1/3 panelled 2/3 glazed wooden shutters for
doors/windows including oxidised iron butt hinges (100mm x75 mm x3.55
mm) with necessay screws (other things to be measured and paid separately
including glass panes)

A).With Teak wood / Sissu wood.


B.(iii). 30 mm thick. sq.m. 7.02
9.9.9 Providing, fitting and fixing fully glazed clerestory window and fan light
including fitting and fixing 2 M.S pivot hinges (75mm x 20mm x 3mm), eye
hook and nylon chord complete (glass panes shall be measured and paid
separately).

A).With Teak wood / Sissu wood.


(iii).30mm thick sq.m. 9.20
16.1 Providing and fixing clear sheet glass beded in putty and fixed with/without
wooden bidding including necessary cutting and glass to be required
sized(payment for wooden bead shall be made separately)

(2). Area of glass panes exceeding 0.15m2 but not exceeding 0.52m2.

(b). 4.00mm thick. sq.m. 3.03


7.4.1 Supplying, fitting and fixing ceiling tiles of 10mm thick made from Duratuff
medium density fibre board in size 1200mm x 1200mm x 10mm with Sal
wood timber frame (to be measured and paid separately)leaving an expansion
gap of 3mm with necessary nails, screws etc. including 1st class local wood
(Hollock /Bonsum / Sundi etc.)beading of size 50mm x 12mm complete as
directed and specified. sq.m. 43.56

8.1.35 Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels
including fitting and fixing self drilling, self tapping screws complete (Roof
trusses, purlins etc. to be measured and paid separately.) .TATA Blue
scope/Dyna roof / Wonder Roof or equivalent as directed by the Deptt.

(iv) 0.55 mm thick sq.m. 72.79


1.3 Earth/ sand filling in plinth in layers not more than 150mm thick including
necessary carriage, watering, ramming etc. complete as directed and specified
including payment of land compensation, forest royalty, sales tax and other
duties and taxes as may be necessary.

( c) With river sand or silt (predominently non plastic) by truck carriage including
loading to the site of work cu.m. 29.70
13.2.2 f) Distempering with dry distemper of approved brand and manufacture(two
coats)and of required shade on new wall surface to give an even shade, over
and including priming coat of white primer after throughly brushing the
surface free from mortar dropings and other foreign matter and including
preparing surface even and sand papered smooth. sq.m. 163.06

13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm
in girth/width after and including preparing the surface by throughly cleaning
oil, grease, dirt snd other foreign matter , sand papering and knotting.

(a). With ready mixed paint , Wood primer (pink) sq.m. 65.90
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based
surface with enamel paint of approved brand and manufacture (Asian paint/
Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including
cleaning the surfaces of all dirt, dust and other foreign matter sand papering
and stopping.

(i).Surfaces over 100mm in width or girth.


a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/
Nerolac). sq.m. 65.90
13.7.2 Applying primary coat over new steel and other metal surface over 100m in
width or girth after preparing the surface by throughly cleaning oil,grease, dirt
and other foreign matter and scoured with wire brushes, fine steels, wood
scrapers and sand paper.

a). With ready mixed "red-lead/ red oxide" primer. sq.m. 17.50
13.7.4 Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint of approved brand and manufacture(Asian paint/
Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including
cleaning the surface of all dirt, dust and other foreign matter.

(i).Surfaces over 100mm in width or girth.


b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
sq.m. 17.50
15.1.1 Supplying, fitting, fixing electrocoloured iron fittings of approved make,
resonably smooth, free from sharp edges and corners, flaws and other defects
and with counter sunk holes for wood screws including necessary screws etc.
complete.

a) Sliding door bolt


ii) 250mm x 16mm each 3
b) Door handle
iii) 150mm each 8
c) Tower bolt
iv) 150mm x 10mm each 14
ANNEXURE-15

CONSTRUCTION OF ASEB's 25 KVA S/S WITH 11 KVA LINE FOR PROVIDING SERVICE
CONNECTION AT (INTAKE POINT) OF PUB DATTA KUCHI PWSS

On the basis of ASEB's approved rate

Sl No Description of Item Unit Qnty


1 25 KVA Transformer No 1
2 PSC POLE- 9.75 MTR No 6
3 11 KV Disc-45 KN No 5
4 11 KV Diisc H/W fitting Set 7
5 11 KV 'T' crossam No 9
6 11 KV pin insulator No 8
7 11 KV GI pin No 6
8 M.S Channel 100 x 50 x 6 x 2200 m No 5
9 Rabit conductor Mtrs 35
10 H T Stay set Set 10
11 11 Guy insulator No 15
12 Stay wire 7/10 SWG Kg 56
13 11 KV D.O 150 A Set 1
14 11 KV L.A Set 1
15 C.I earth pipe No 1
16 Nuts & Bolts (Assortied) Kg 105
17 G.I wire (6 swg) Kg 30
18 By Matellic Cable Conductor No 2
19 Metre Cabinet No 1
20 XLPE Cable Mtrs 900
21 Main Switch 100(ARC) No 1
22 Cut out 100 amp No 2

(a) Cost of Materials


(b) Storage & Carriage 5% on (a)
( c) Contigency 3% on (a)
(d) Labour Charge 25% on (a)
Pole Grouting Each 6
Sub station fencing Each 1
ANNEXURE-16

CONSTRUCTION OF ASEB's 25 KVA S/S WITH 11 KVA LINE FOR PROVIDING SERVICE
CONNECTION AT (T.P SITE) OF PUB DATTA KUCHI PWSS

On the basis of ASEB's approved rate

Sl No Description of Item Unit Qnty


1 25 KVA Transformer No 1
2 PSC POLE- 9.75 MTR No 3
3 11 KV Disc-45 KN No 2
4 11 KV Diisc H/W fitting Set 3
5 11 KV 'T' crossam No 6
6 11 KV pin insulator No 8
7 11 KV GI pin No 5
8 M.S Channel 100 x 50 x 6 x 2200 m No 3
9 Rabit conductor Mtrs 30
10 H T Stay set Set 15
11 11 Guy insulator No 15
12 Stay wire 7/10 SWG Kg 42
13 11 KV D.O 150 A Set 1
14 11 KV L.A Set 1
15 C.I earth pipe No 2
16 Nuts & Bolts (Assortied) Kg 20
17 G.I wire (6 swg) Kg 13
18 By Matellic Cable Conductor No 5
19 Metre Cabinet No 1
20 XLPE Cable Mtrs 750
21 Main Switch 100(ARC) No 1
22 Cut out 100 amp No 6

(a) Cost of Materials


(b) Storage & Carriage 5% on (a)
( c) Contigency 3% on (a)
(d) Labour Charge 25% on (a)
Pole Grouting Each 3
Sub station fencing Each 1
ANNEXURE-17

Name of Work:- Site Development of PUB DATTA KUCHI PWSS.

As per the APWD SOR (Bldg) for the year 2013-14


Sch
Item of work Unit Qnty
no
1.4 Raising low site around the building with approved soil obtained from
outside by truck carriage including breaking clods, dressing etc.
complete including paying necessary land compensation, municipal
gate fees, if any monopoly duty etc. (profile measurement to be taken
and 12.5% deduction for shrinkage to be made from total quantityetc.
complete as directed and specified, including forest royality within a
distance of 8.00Km. (Forest royality shall be reimbrushed on
production of necessary certificate from the forest authority duly
countersigned by D.F.O. concerned).

ii) Other than Guwahati municipality area. cu.m. 411.12


Qnty=30.00m x30.00m x0.4568m =411.12um
ANNEXURE-18

Name of Work= Construction of compound fencing around the T.P site of PUB
DATTA KUCHIPWSS.

As per the APWD SOR (Bldg) for the year 2013-14


Sch
Item of work Unit Qnty
no
1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings
of column, steps, septic tank etc. including refilling (return filling) the quantity
........ ramming etc. and removal of surplus earth with all lead and lifts as directed
and specified in the following classification of soils including bailing out water
where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.m


8.42
.
4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing the
subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(a).Brick on flat soling. sq.m


. 10.79
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and specified
including dewatering if necessary, and curing complete (shuttering where necessary
shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using
mixture machine) Cum 0.81
18.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevant
1 I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting
and bending to proper shapes and length as per details, supplying and binding with
20G annealed black wire and placing in position with proper blocks, supports,
chairs, spacers etc. complete (upto 1st floor level).

a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL

(i) TMT corrosion resistant steel (CRS) qtl 7.93


c) c) ISI approved mild steel reinforcement bar (M.S. Bar) qtl 1.94
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of propping and
centering below supporting floor to ceiling not exceeding 4.0M and removal of the
same for in-situ reinforced concrete and plain concrete work in:

3.1.1. Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
1
(ii) Using 38 mm thick plank sq.m
. 17.27
3.1.1. Sides of tie beams, grade beams etc. at or below ground level.
2
(i) Using 38mm thick plank sq.m
. 48.00
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane
vertical face
(i) Using 38mm thick plank sq.m
. 28.11
2.2.1 Providing and laying plain/reinforced cement croncrete works cement with coarse
sand & 20mm down graded stone aggregate including dewatering if necessary, and
curing complete but excluding cost of form work and reinforcement for reinforced
cement concrete work (form work and reinforcement will be measured and paid
separately)

(I) Using mixture machine


(A) In sub - structure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base slab,
retaining walls, walls of septic tank, inspection pit and the like and other works not
less than 100mm thick up to plinth level.

N) Without using admixture, plasticiser


(b) M20 grade concret or Prop. 1:1.5:3 Cum 1.19
B) In superstructure from plinth level up to Ist floor level.

(ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support,
balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except
spiral staircase and landing ) including preparing the top surface and finishing of
nosing.

N) Without using admixture, plasticiser


(a) M20 grade concret or Prop. 1:1.5:3 Cum 4.93
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and
dewatering if necessary, and curing complete as directed

(I) In sub-structure up to plinth level including dewatering if necessary

(b). In proportion 1:4. cu.m


. 15.57
4.1.9 112 mm thick reinforced brick wall in prop 1:5 reinforced with two lines of M.S
rod/ Tor steel as specified embeded in 38 mm thick concrete course in prop.1:2:4
with coarse agg. 12mm down at every fourth courses embeded with protruding rod
in column including curing etc.complete as directed ( M.S rod/Tor steel shall be
measured and paid separately) in super structure above plinth up to 1st floor level. sq.m
55.47
.

6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall for interior
plastering up to 1st floor level including arises, internal rounded angles, not
exceeding 80mm girth and finished even and smooth including curing complete as
directed.

A) On rough side
(b). In cement mortar 1:4 sq.m 58.00
.
B) On fair side
(b). In cement mortar 1:4 sq.m
. 63.88
13.2. a) Colour washing with lime on wall surface (two coats) over and including a
1 priming coat of white washing to give an even shade after throughly brooming the
surface to remove all dirt, dust, mortar drops and other foreign matter. sq.m 123.8
. 8

Applying primary coat over new steel and other metal surface over 100m in width
13.7. or girth after preparing the surface by throughly cleaning oil,grease, dirt and other
2 foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand
paper.

a). With ready mixed "red-lead/ red oxide" primer. sq.m 8.16
.
13.7. Painting two coats (excluding priming coat) on new steel and other metal surface
4 with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/
ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the
surface of all dirt, dust and other foreign matter.

(i).Surfaces over 100mm in width or girth.


b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). sq.m 100.9
. 6
17.10 Supplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm
x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification
detailed below including supplying, fitting and fixing hooks, eye bolts with nuts,
staples and bolts including three horizontal lines of G.I wire 10 S.W.G at
top,middle and bottom and with one vertical line to each fencing post for keeping
the fencing tight and erect complete, including one coat of primer painting to M.S
angle iron post in P.C.C base etc. with following. sq.m
92.80
.

a) Corner and end posts with M.S angle of size 50mmx50mmx 5mm and length not
less than 1800mm only duly slotted and bottom torqued with two numbers as stay
posts..

b) Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less
than 1800mm only duly slotted and bottom torqued and splayed.
c) Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than
1800mm duly slotted and bottom torqued and splayed. All M.S angle iron posts are
to be fitted to P.C.C base embedded not less than 600mm (P.C.C. work shall be
measured and paid separately).

17.11 Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from
50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia
M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at
200mm apart from bottom flat to middle flat including drilling, welding etc.
complete. All vertical bars are to be protruded at least 100mm above the middle
and top flat is to be flattended and pointed as directed. Necessary locking
arrangement on both faces, arrangement for temporary closing the gate and 2 nos.(
minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be
embeded in C.C brick pillars as necessary including a red oxide painting to all iron
works as directed and specified. (Separate payment will be made for posts).
Qtl 2.70
ANNEXURE-19A

Internal Electrification for Grade IV Staff quarter of PUB DATTA KUCHIPWSS.

As per the APWD SOR (Electrical) for the year 2013-14)


Sch
Description of work Unit Quantity
no
3.1 Wiring for light / fan / call bell point with 2 x 1.5 sq. mm
P.V.C.insulated single core unsheathed industrial (Multistandard)
cable FR conforming to IS- 694 : 1990 with flexible bright annealed
electolytic copper conductor for voltage grade up to 1100 volts
(Finolex / RR Kabel or equivalent make as approved by the Deptt)
......... (anchor penta / Gold medal / Kolor Kany. Kom/ Havells or
equivalent make as approved by the Deptt.) etc. complete.

3.1.1 a) Short point up to 3.0 M. length point 2


3.1.2 b)Medium point up to 6.0 M length. point 2
3.1.3 c) long point up to 10 m length point 4
3.2 Wiring 5 a pin 6 Amps plug point with 1.5 sq. mm p.v.c insulated
single core unsheathed industrial (multistrand) cable FR conforming
to IS -694 : 1990 with flexible bright annealed electrolytic copper
conductor for voltage grade up to 1100 volts (Finolex / RR Kabel or
equivalent make as approved by the Deptt) ......... (anchor penta /
Gold medal / Kolor Kany. Kom/ Havells or equivalent make as
approved by the Deptt.) GI/MS switch board (I.S.I marked) with
phenolic laminated sheet cover including earth continuty with 1.5
sq.mm ..... where placed elsewhere.etc. complete.

3.2.1 a) Short point up to 3.0 M. length point 2


3.2.2 b)Medium point up to 6.0 M length. point 2
3.2.3 c) long point up to 10 m length Per point 4
11.17 Supplying and fixing of bulk head fitting suitable for CFL lamp
complete with all accessories including 20 watts CFL lamp and
connection as approved by the Deptt. As required. Each 10
3.7 Wiring for drawing sub-main line with PVC insulated single core
unsheathed industrial (multistrand) cable FR conforming to IS -694 :
1990 with flexible bright annealed electrolytic copper conductor for
voltage grade up to 1100 volts (Finolex / RR Kabel or equivalent
make as approved by the Deptt) in ISI marked steel conduit pipe
including earth continuity in surface / recessed conduit wiring system.

a) With 2 x 4 Sq.mm + earth continuty with 1x 2.5 Sq.mm cable in 20


mm dia rigid steel conduit.
Per Mtr. 50
27.1 Supplying including fitting fixing of following A.C. Ceiling fan
complete with all accessories like down rod, canopy etc. of following
sweeps with making necessary connection as approved by the
Deptt.)as required complete and as directed by the Department
[Without regulator].

Premium model 1400 mm Sweep. (ORIENT PSPO make)


/Premium model 1400 mm Sweep SS-390 Deco. Havells make)
Each 2
8.3 Supplying and fixing 32 mm dia ISI marked hot dip galvanised pipe
(AKG or equivalent as approved by the Deptt. ) on surface including
painting etc. as required.

Per Mtr. 15
12.1.1 Providing and fixing I.C.T.P. ans N. link main switch with rewire able
fuses of 500 Volt grade (HPL/ GECO/ ANCHOR or equivalent make)
including drilling boards/iron frames and fixing with bolts and nuts
and connections as approved by the deptt. etc. complete.

a) 16 Amp capacity S.P.N.


Each 1
22.8 Supply, installation and testing of G.I earth station with perforated 50
mm dia and 3.00 m long heavy duty G.I pipe with necessary 50 mm
dia G.I fittings such as socket, Tee, Elbow, nipple and 65mm x 50mm
G.I reducing socket for funnel including locking arrangement 300 mm
x300 mm x6 mm hinged cover C.I earth plate complete with digging
of earth pit , construction of brick chamber and plastering of both
inner & outer surface of wall as specified and directed by the deptt. Each 1
ANNEXURE-19B

Internal Electrification of Clear Water Pump House of PUB DATTA KUCHIWater


Supply Scheme

As per the APWD SOR (Electrical) for the year 2013-14)


Sch
Description of work Unit Quantity
no
3.1 Wiring for light / fan / call bell point with 2 x 1.5 sq. mm
P.V.C.insulated single core unsheathed industrial (Multistandard)
cable FR conforming to IS- 694 : 1990 with flexible bright annealed
electolytic copper conductor for voltage grade up to 1100 volts
(Finolex / RR Kabel or equivalent make as approved by the Deptt)
......... (anchor penta / Gold medal / Kolor Kany. Kom/ Havells or
equivalent make as approved by the Deptt.) etc. complete.

3.1.1 a) Short point up to 3.0 M. length point 1


3.1.2 b)Medium point up to 6.0 M length. point 3
11.17 Supplying and fixing of bulk head fitting suitable for CFL lamp
complete with all accessories including 20 watts CFL lamp and
connection as approved by the Deptt. As required. Each 3

3.7 Wiring for drawing sub-main line with PVC insulated single core
unsheathed industrial (multistrand) cable FR conforming to IS -694 :
1990 with flexible bright annealed electrolytic copper conductor for
voltage grade up to 1100 volts (Finolex / RR Kabel or equivalent
make as approved by the Deptt) in ISI marked steel conduit pipe
including earth continuity in surface / recessed conduit wiring
system.

a) With 2 x 4 Sq.mm + earth continuty with 1x 2.5 Sq.mm cable in


20 mm dia rigid steel conduit.
Per Mtr. 35
8.3 Supplying and fixing 32 mm dia ISI marked hot dip galvanised pipe
(AKG or equivalent as approved by the Deptt. ) on surface including
painting etc. as required.

Per Mtr. 15
22.8 Supply, installation and testing of G.I earth station with perforated 50
mm dia and 3.00 m long heavy duty G.I pipe with necessary 50 mm
dia G.I fittings such as socket, Tee, Elbow, nipple and 65mm x
50mm G.I reducing socket for funnel including locking arrangement
300 mm x300 mm x6 mm hinged cover C.I earth plate complete with
digging of earth pit , construction of brick chamber and plastering of
both inner & outer surface of wall as specified and directed by the Each 1
deptt.

ANNEXURE-19C

Internal Electrification of Raw Water Pump House cum duty room of PUB DATTA
KUCHIWater Supply Scheme

As per the APWD SOR (Electrical) for the year 2013-14)


Sch
Description of work Unit Quantity
no
3.1 Wiring for light / fan / call bell point with 2 x 1.5 sq. mm
P.V.C.insulated single core unsheathed industrial (Multistandard)
cable FR conforming to IS- 694 : 1990 with flexible bright
annealed electolytic copper conductor for voltage grade up to 1100
volts (Finolex / RR Kabel or equivalent make as approved by the
Deptt) ......... (anchor penta / Gold medal / Kolor Kany. Kom/
Havells or equivalent make as approved by the Deptt.) etc.
complete.

3.1.1 a) Short point up to 3.0 M. length point 1


3.1.2 b)Medium point up to 6.0 M length. point 3
11.17 Supplying and fixing of bulk head fitting suitable for CFL lamp
complete with all accessories including 20 watts CFL lamp and
connection as approved by the Deptt. As required. Each 3

3.7 Wiring for drawing sub-main line with PVC insulated single core
unsheathed industrial (multistrand) cable FR conforming to IS -694
: 1990 with flexible bright annealed electrolytic copper conductor
for voltage grade up to 1100 volts (Finolex / RR Kabel or
equivalent make as approved by the Deptt) in ISI marked steel
conduit pipe including earth continuity in surface / recessed
conduit wiring system.

a) With 2 x 4 Sq.mm + earth continuty with 1x 2.5 Sq.mm cable in


20 mm dia rigid steel conduit.
Per Mtr. 50
27.1 Supplying including fitting fixing of following A.C. Ceiling fan
complete with all accessories like down rod, canopy etc. of
following sweeps with making necessary connection as approved
by the Deptt.)as required complete and as directed by the
Department [Without regulator].

Premium model 1400 mm Sweep. (ORIENT PSPO make)


/Premium model 1400 mm Sweep SS-390 Deco. Havells make)
Each 1
8.3 Supplying and fixing 32 mm dia ISI marked hot dip galvanised
pipe (AKG or equivalent as approved by the Deptt. ) on surface
including painting etc. as required.

Per Mtr. 15
22.8 Supply, installation and testing of G.I earth station with perforated
50 mm dia and 3.00 m long heavy duty G.I pipe with necessary 50
mm dia G.I fittings such as socket, Tee, Elbow, nipple and 65mm x
50mm G.I reducing socket for funnel including locking
arrangement 300 mm x300 mm x6 mm hinged cover C.I earth plate
complete with digging of earth pit , construction of brick chamber
and plastering of both inner & outer surface of wall as specified Each 1
and directed by the deptt.
ANNEXURE-19D

External electrification (Campus Lighting) of PUB DATTA KUCHI PWSS

as per PWD(elect) Schedule of rates for the year 2013-14


Sch
Particulars Unit Qnty
item No
36.1

Supplying and errection PSC pole 7.5 m long , the pole is to be


irrection in 1:2:3 plain cement concrete foundation of size 1.50 m x Each 4
0.45 m x 0.45m having P.C.C base foundation 15 cm x 60 cm x 60 cm
including edge brick soling and plastering above G.L portion (0.30
m) complete with excavation of earth , handling of surplus soil,
debries etc. to the proper place and refilling etc. as specified and as
directed by the Deptt.
36.6
Supplying anf fitting fixing of galvanised L.T.T cross arm complete
with clamps, bolts, nuts etc. as required and as directed by the Each 4
Deptt.
25.1.2 Philips make type HGS120 1 x TL-D36W IC for lamp 1XTL -D36W /
Crompton Greaves make SFE1614HSB/AL for lamp 1x 36W
FTL/Havells make :LHRF 08104011 for lamp 1 x 36 W FTL(AL)

Each 4
32.1

Supplying and laying of following size PVC/XLPE insulated and PVC


sheathed 1.1 KV grade solid Aluminium conductor up to 10 Sq mm
balance standard conductor , XLPE Insulated , cores laid up , PVC
tape inner sheathed , Armour (Aluminium for single core up tpo 70
sq. mm balance aluminium strip , Galvanized for cable up to 2 X 10
sq.mm , 4 x 6 sq.mm balance all galvanized steel strip .....................
sand cushioning etc. complete handling of surplus spoil, debries to
proper place as specified and directed by the Deptt. (Nicco /
Havells/ RPG/ CCI/ Polycab/ Gloster/ Finolex make or equivalent)

32.1.1 2 Core A2 XWaY A2XFaY


32.1.1.1 b) 4.0 sq mm core UG cable RM 80

--------------------------------
ANNEXURE-20

Name of work-Construction of Box Culvert and approach road with spreading 150
mm thick sand gravel of PUB DATTA KUCHI PWSS

As per A.P. W.D (roads) schedule of rates for the year 2013-14

Sl No Description of Item Unit Quantity


1.1 Earthwork in excavation for foundation trenches of walls, retaining walls,
footings of column, steps, septic tank etc. including refilling (return filling)
the quantity as necessary after completion of work, breaking clods in return
filling, dressing, watering and ramming etc. and removal of surplus earth
with all lead and lifts as directed and specified in the following classification
of soils including bailing out water where necessary as directed and
specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.m. 5.93


4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing
the subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(a).Brick on flat soling. sq.m. 7.50


2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm
in foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using
mixture machine) Cum 0.63
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of
propping and centering below supporting floor to ceiling not exceeding 4.0M
and removal of the same for in-situ reinforced concrete and plain concrete
work in:
3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete
works etc.
(i) Using 38mm thick plank sq.m. 1.38
4.1.4 Brick work in cement morter with 1st class brick including racking out joints
and dewatering if necessary, and curing complete as directed

(I) In sub-structure up to plinth level including dewatering if necessary

(b). In proportion 1:4. cu.m. 3.45


25.12 Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4
reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20
gauge black annealed wire with necessary shuttering , curing etc. complete
including fixing in position as directed.

a) 100mm thick slab sq.m. 4.73


6.2.3 20 mm thick Cement plaster in two coats, on single or half brick walls for
interior plastering up to 1st floor level including arises, internal rounded
angles,chamfers and / or rounded angles not exceeding 80mm in girth and
finished even and smooth including curing complete as directed.

A) On fair side (backing coat 10 mm and finishing coat 10 mm thick)

(b). In cement mortar 1:4 sq.m. 8.97


Excavation in soil by manual means
3.1/ a) Excavation for roadway in soil using manual means including loading in
301 truck for carrying of c earth to embankment site with all lifts and lead up to
1000 metres.

30.00 m x (7.00 m + 4.50 m)/2 x 0.60 m=106.95Cu.M


cu.m. 106.95
Analysis

Supplying and spreading sand gravel on the approach road ramming, packing
etc. complete as directed and specified including payment of forest royality
and sale tax and other duties and taxes may be necessary.
Analysis of Sand & Gravel
60% Gravel per Cum quantity
40% Sand per Cum quantity
Rate (As per present market)

(A) 20 mm down normal size crusher broken Rs1800/Cum


(B) Fine River Sand Rs 1100/Cum
(i) 60% of (A) Rs=1080.00
(ii) 40% of (B) Rs= 440.00
Basic cost Rs=1520.00
Cost of carriage25% Rs= 380.00
Labou for spreading 30% Rs= 456.00
Total Rs=2356.00
Contractors profit 10% Rs= 235.60
Net cost per CUM Rs=2591.60
Required Quantity
Length of Approach Road =30.00 m
Width of the Road =4.50 m
Thickness of Sand Gravel Packing 0.15m
Quantity of Sand Gravel
30.00m x 4.50 m x 0.15 m=20.25 Cum Cum 20.25

ANNEXURE-21

T& P materials of PUB DATTA KUCHI PWSS

As per CPHE schedule of rates for the year 2008-09

Sl No Item of work Unit Rate

1 Slide wrench(Taparia)
300 mm Each Rs.225.00
200 mm Each Rs.180.00
150 mm Each Rs.175.00
2 Pipe Wrench(Taparia)
450mm Each Rs.1245.00
600 mm Each Rs.1530.00

3 Chain tongue(Taparia)
450mm Each Rs.2600.00
600mm Each Rs.2900.00

4 Chain Each Rs.400.00


ANNEXURE-22

Trial Run of PUB DATTA KUCHIpipe water supply scheme

Rate Description of work Unit Qnty

Analysis Trial run including training of operation and maintance staff Job 1

1
Checking testing and jointing PVC pipe line for any leakage, pumping set
job 1
and inter connection etc. including cost of materials,solvent etc.

2
Plumber (1 st class) 1 no for 10 days @ Rs300.00/Each/day Each 10
3 Electrician 1 no for 10 days @ Rs300/Each/day Each 10
4
Skilled labour 1 nos for 10 days @Rs300.00 Each/day Each 10

5
Unskilled labour 1 no for 10 days @ Rs208.00Each/Day Each 10
6
Training of operation and maintanance staff about operation of pumping
sets,internal connection,minor repairing of components etc. (Expecditure
including cost of lodging entertainment cost,travelling Each 20
allowances,honourium to resource person @ Rs 500.00/day 2 nos for 10
days
ANNEXURE-23

Making sign board, (Sailent features) of PUB DATTA KUCHI PWSS

As per (APWD) (buld) Schedule of 2013-14


sch no Particulars Unit Qnty
1.1 EARTHWORK IN EXCAVATION
Earthwork in excavation for foundation trenches of walls,
retaining walls, footings of column, steps, septic tank etc.
including refilling (return filling) the quantity as necessary after
completion of work, breaking clods in return filling, dressing,
watering and ramming etc. and removal of surplus earth with all
lead and lifts as directed and specified in the following
classification of soils including bailing out water where necessary
as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil


4 no x 0.50m x 0.5m x0.50 m=1.0cum cu.m. 1.00
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm
to 32mm in foundation bed for footing steps, walls, brick works
etc. as directed and specified including dewatering if necessary,
and curing complete (shuttering where necessary shall be
measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by


volume (using mixture machine)
(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by
volume (using mixture machine) Cum 0.18
3.1.1 Providing form work of ordinary timber planking so as to give a
rough finish including centering, shuttering, strutting and propping
etc., height of propping and centering below supporting floor to
ceiling not exceeding 4.0M and removal of the same for in-situ
reinforced concrete and plain concrete work in:

3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass
concrete works etc.
(ii) Using 25mm thick plank
4 x 4 x 0.30m x 0.50m=2.4 sq.m. 2.40
18.3.2 Providing welding, fitting, fixing, hoisting and fixing of roof
trusses with purlin, bottom runner etc. fabricated out of a
combination of two or all of the following sections: (i) square
hollow sections (SHS/RHS) (ii) rectangular hollow section and
(iii) M.S. black-tubes conforming to relevant I.S. code 1161-1968
as per approved design and drawing including M.S. cleat, base
plate, bolts and nuts which ever required, including that required
for fixing the ceiling and one coat of red oxide Zinc Chromate
primer to all steel surface etc. complete as directed as per
specifications.

For silent features


32 mm MS tube
2 x 5.2m =8.2 m=46.07Kg
2 x 1.5 m=3.0 m=31.01 Kg
250 mm x 250mm x 4 mm MS plate
2 nos=5.40 kg
25mm x4 mm M.S plate
4 x 4.2 m= 16.8m=13.19Kg
3 mm ms plate
1 x 2.4mx1..5=3.60 sqm=84.78kg
Total wt= (46.07+31.01+ 5.40+13.19+84.78) =180kg

a)Using TATA makeRHS/SHS of gade 310 conforming to I:S


Specification : 4923:1997 qtl 1.8

DAR
painting one coat including priming coat in the plain sheet ,
cleaning the surface of all dirt,dust and other foreign matter and
lettering as per formate prescribed by the deptt. Including hanging
the wall as directed and specified.

Nos of letter=2056 Nos 2056


ANNEXURE-24

Name of work-Installation of 5 KVA Diesel Generator set at INTAKE POINT site of


PUB DATTA KUCHI PWSS

As per A.P. W.D (build)(Elect) schedule of rates for the year 2013-14.

Sl No Description of Item Unit Quantity


41.2 Supplying including installation, testing and commissioning of
Air/Water Cooled Diesel Generator set coupled to suitable
alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. mounted on a 1)
M.S. Fabricated base frame.,2) M.S. fuel tank of required
capacity.,3) Residual Silencer.,4) AMF Control Panel.5) Suitable
batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure
complete with all accessories as specified and directed by the
department conforming to IS comprising the Technical
Specification.. as per manufacturer. (RANGE FROM 5 KVA TO
625 KV . Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson,
Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy
somer or equivalent alternator.

41.2.1.1 5 - 1 - 1600x820x1530 - 650 Kg -A/C Each 1


ANNEXURE-25

Name of work-Installation of 5 KVA Diesel Generator set at T.P site of PUB DATTA
KUCHIPWSS

As per A.P. W.D (build)(Elect) schedule of rates for the year 2013-14.

Sl No Description of Item Unit Quantity


41.2 Supplying including installation, testing and commissioning of
Air/Water Cooled Diesel Generator set coupled to suitable
alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. mounted on a 1)
M.S. Fabricated base frame.,2) M.S. fuel tank of required
capacity.,3) Residual Silencer.,4) AMF Control Panel.5) Suitable
batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure
complete with all accessories as specified and directed by the
department conforming to IS comprising the Technical
Specification.. as per manufacturer. (RANGE FROM 5 KVA TO
625 KV . Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson,
Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy
somer or equivalent alternator.

41.2.1.1 5 - 1 - 1600x820x1530 - 650 Kg -A/C Each 1


ANNEXURE-26

METERED HOUSE CONNECTION FOR of PUB DATTA KUCHIPWSS

Sl Description Unit Qty


a)

Providing PVC Shaddle Piece of average size 110 mm x 15 mm


including the cost of all required labour and materials, making holes
in the distribution pipe, and including all taxes and duties as
applicable, all complete, as directed and specified No 1
b)

Providing 15 mm dia brass ferrul cock including the cost of all


required labour and materials, making holes in the distribution pipe,
and including all taxes and duties as applicable, all complete, as
directed and specified No 1
c)

Providing and fixing S.F.M.C. Brand 3 layer (Outer green coloured


UV Stabilised, middle black coloured UV Stabilised and inermost
layer white coloured with antimicrobial property) Fusion welded
PP-R (Poly propylene- random copolymer) Pipes, SDR 7.4 having
thermal stability for hot and cold water supply including all plain
PP-R fittings and brass threaded PP-R fitting and clamping, cutting
and making good to the damages.
I) Exposed or in trenches
b) PN-16 Pipe,20 mm OD,SDR-7.4
Rm 10
ANNEXURE-27

Name of work-Construction of twin brick lined circular septic pit , drain, junction
chamber and fitting & fixing of pan & trap etc. (low cost latrine) for PUB DATTA
KUCHI PWSS
Sch Quantit
Item of work Unit
no y
1.1 Earthwork in excavation for foundation trenches of walls, retaining walls,
footings of column, steps, septic tank etc. including refilling (return filling) the
quantity as necessary after completion of work, breaking clods in return filling,
dressing, watering and ramming etc. and removal of surplus earth with all lead
and lifts as directed and specified in the following classification of soils
including bailing out water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.


m. 2.94
2.1.1

Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in
foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using
Cum 0.14
mixture machine)
4.1.4 Brick work in cement morter with 1st class brick including racking out joints
and dewatering if necessary, and curing complete as directed

(I) In sub-structure up to plinth level including dewatering if necessary

(b). In proportion 1:4. cu.


m. 2.02
25.12 Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4
reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20
gauge black annealed wire with necessary shuttering , curing etc. complete
including fixing in position as directed.
b) 75mm thick slab sq.m
. 2.41
6.2.2 15 mm thick Cement plaster in single coat on single or half brick wall for
interior plastering up to 1st floor level including arises, internal rounded angles,
not exceeding 80mm girth and finished even and smooth including curing
complete as directed.

B) On fair side
(b). In cement mortar 1:4 sq.m
. 24.41
1.3 Earth/ sand filling in plinth in layers not more than 150mm thick including
necessary carriage, watering, ramming etc. complete as directed and specified
including payment of land compensation, forest royalty, sales tax and other
duties and taxes as may be necessary.

( c) With river sand or silt (predominently non plastic) by truck carriage including
loading to the site of work cu.
0.65
m.

4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing
the subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(a).Brick on flat soling. sq.m


. 1.44
5.1.6 40 mm thick red oxide floor with under layer of 30 mm thick cement concrete
in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of size 20 mm and
down) and top layer of 10mm thick plaster of cement red-oxide of iron per 50
kg of cement in prop. 1:3 (1 cement red oxide: 3 coarse sand) finished with a
floating coat of neat cement red oxide mix of same proportion. sq.m
1.44
.
9.2.1 Providing undressed wood work in roof truss, rafter, purlin, tie and the like
including hoisting and fixing in position with necessary spikes, nails including
M.S straps with bolt and nuts etc.complete with kiricide oiling two coats to all
timber.m.embers and two coats of anticorrosive paint to M.S straps (M.S flats,
angle cleats, and bolt and nuts required for flat and angle cleats wherever used
shall be measured and paid separately).

cu.
(b). With Hollock/ Sundi/ Sam m. 0.04
8.1.35 Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including
fitting and fixing self drilling, self tapping screws complete (Roof trusses,
purlins etc. to be measured and paid separately.) .TATA Blue scope/Dyna roof /
Wonder Roof or equivalent as directed by the Deptt.

(iv) 0.55 mm thick sq.m


. 2.25
9.9.6 Providing, fitting and fixing 1 st class local wood battened, ledged and braced
door and window shutters including oxidised iron but hings (100 mm x 58 mm
x 1.90 mm ) 6 nos with necessary screws.

(a).Using Bonsum / Holock wood


(i) 25 mm thick sq.m
. 1.80
15.1.1 Supplying, fitting, fixing electrocoloured iron fittings of approved make,
resonably smooth, free from sharp edges and corners, flaws and other defects
and with counter sunk holes for wood screws including necessary screws etc.
complete.

a) Sliding door bolt


ii) 250mm x 16mm each 1
b) Door handle
ii) 100mm each 2
c) Tower bolt
ii) 250mm x 10mm each 2
13.9.6 Finishing old/new wall with water proofing weather coat smooth anti-fungal
exterior painting of approved make of Dulux (ICI) paint of required shade after
cleaning and clearing the surface etc. including scaffolding complete as directed
at all levels (two coats) sq.m
20.40
.

13.6.3 Applying priming coat over new wood and wood based surfaces over 100mm
in girth/width after and including preparing the surface by throughly cleaning
oil, grease, dirt snd other foreign matter , sand papering and knotting.

(a). With ready mixed paint , Wood primer (pink) sq.m


. 3.60
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based
surface with enamel paint of approved brand and manufacture (Asian paint/
Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including
cleaning the surfaces of all dirt, dust and other foreign matter sand papering and
stopping.

(i).Surfaces over 100mm in width or girth.


a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). sq.m
3.60
.
(1.1) Supplying fitting and fixing virtuous water closet squatting pan ( Indian type
san WC Orissa pattern) with all fitings and fixtures complete including cutting and
making good to the wall & floor where required (flushing sistern to be paid
seperately)

1.1.1 Indian type W.C Orissa pattern of size 580 x 440 mm

ii) Hindware make Eac


h 1
(1.36. Supplying fitting and fixing I.S.I marked or simillar approved H.C.I pipe
1) including bolts and nuts and other fittings as required and complete at all
san levels including below G.L as directed and specified.

ii 100 mm dia RM 2
1.36. Supplying fitting and fixing H.C.I bend with door including bolts and nuts and
3 other fittings as required and complete at all levels including below G.L as
directed and specified.

ii 100 mm dia Eac 2


h
1.36. Supplying fitting and fixing H.C.I plain equal Y junction including necessary
6 fittings complete at all levels including below G.L as directed and specified.

ii 100 mm dia Eac


h 1

ANNEXURE-28

Name of work= Provision of safe disposal of waste water of PUB DATTA KUCHI
PWSS

Sl No Item of works Unit Qnty


1.1 Earthwork in excavation for foundation trenches of walls, retaining walls,
footings of column, steps, septic tank etc. including refilling (return filling)
the quantity as necessary after completion of work, breaking clods in return
filling, dressing, watering and ramming etc. and removal of surplus earth with
all lead and lifts as directed and specified in the following classification of
soils including bailing out water where necessary as directed and specified.
(A) Upto a depth of 2.00 m below the existing G.L.

(a) In ordinary soil cu.m. 11.84


2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm
in foundation bed for footing steps, walls, brick works etc. as directed and
specified including dewatering if necessary, and curing complete (shuttering
where necessary shall be measured and paid separately).

(a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using
mixture machine) Cum 0.86

4.1.1 Providing brick soling in foundation and under floor with stone/ best quality
picked jhama brick, sand packed and laid to level and in panel after preparing
the subgrade as directed including all labour and materials and if necessary
dewatering, complete.

(a).Brick on flat soling. sq.m. 8.61


25.12 Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4
reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20
gauge black annealed wire with necessary shuttering , curing etc. complete
including fixing in position as directed.

a) 100mm thick slab sq.m. 8.00


3.1.1 Providing form work of ordinary timber planking so as to give a rough finish
including centering, shuttering, strutting and propping etc., height of propping
and centering below supporting floor to ceiling not exceeding 4.0M and
removal of the same for in-situ reinforced concrete and plain concrete work
in:

3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete
works etc.
(ii) Using 25mm thick plank sq.m. 1.24
4.1.4 Brick work in cement morter with 1st class brick including racking out joints
and dewatering if necessary, and curing complete as directed

(I) In sub-structure up to plinth level including dewatering if necessary

(b). In proportion 1:4. cu.m. 4.13


4.2.7(PHE) Labour charge for carrying and laying in position in trenches P.V.C. pipes
…………... with jointing materials such as cement lubricant ronghening
surface

140mm dia RM 35.00


4.6.1(PHE) Labour charge for carrying placing in position, fitting and fixing C.I. Sluice
valve(with wheel and cap)C.I. Reflux valve complete with supplying bolts
and nuts 3 mm thick rubber insered sheet etc.(the tail pieces if required will
be paid seperately) all

125 mm dia Each 1


Cost of Materials
125 mm dia Sluice valve Each 1
i) 140 mm dia PVC pipe RM 35
ANNEXURE-29A

Detail survay of Distribution network . Intake point, Treatment plant site etc. for
PUB DATTA KUCHI PWSS

Analysis for detail survay work of considering for one PWSS as one Job

Sch
item Particulars Unit Qnty
No
A Materials

1. Hire charge of Total station Machine= 1 no per day Per Day 10.00

2. Hire charge of Vehicle 1 No per Day Per Day 10.00

3. Paint brass , BM pillar etc L/S 1

B
Labour

1. Survay engineer 1 No per Day p/day 10.00

2. Prisam Man 1 No per Day Per Day 10.00

3. Labour 1 No per Day Per Day 10.00

Shoftware charge L/S 1


ANNEXURE-29B

Prepairing of structural design and drawing of R,C,C Elevated Service Reservoir


including estimating for PUB DATTA KUCHI PWSS

As per APWD (building) Circular

Sl No Item of works Unit Rate


Office Order No: ARC (M) 27/ 84/1 Dt. 10.07.1984

ii) Preparation of detail architectural drawing @


Job 0.70%
0.7% of civil work (0.7% of total estimated cost)

iii) Preparation of structural design and drawings


including supplying design calculation for RCC Job 1.00%
building/Tank etc. (1% of total estimated cost)
ANNEXURE-29C

Name of work= Estimate for Sub Soil investigation at the proposed O.H.R. site for
PUB DATTA KUCHI PWSS

As per APWD (building) Schedule of rates for the year 2013-14

Sl No Item of works Unit Rate


28.1 Collection from the field and testing in the laboratory of
undisturbed soil samples for sub- soil investigation (as per
relevant I.S code) by open drive sampler (100mm dia
boring) through clayey soil layer/ sandy soil layer/ sandy
clay/ sandy silt layer/ clayey silt layer, conduction standard
penetration test (SPT) and collection of SPT sampler,
observation of ground water table, spot level survey to the
bore location and carrying out R.L. from nearest B.M.,
laboratory test (particle size analysis, hydrometer test,
liquid limit determination, plastic limit determination, bulk
limit determination, moisture content determination,
specific gravity determination, triaxal test, direct shear test,
unconfined compression test, consolidation test) including
preparation of sub-soil investigation report complete with
necessary printing and binding (minimum 5 copies)

A. Boring.
(iii) Construction of 100mm machine boring (Drilling) through all
types of gravel,sandy gravel excluding transportation charges.

Nos of Bore hole =2 nos


Depth of each Borehole = 15.00 M r.m. 30
B. Standard Penetration Test (S.P.T.)
(i) Conduction of SPT at equal interval of 1.5m or change
of strata whichever is earlier and collection of disturbed
soil sample from SPT sampler including proper airtight each 15
sealing, labeling.

C. Laboratory test.
(i) Particle size analysis (dry sieving). per test 3
(ii) Particle size analysis (wet sieving). per test 3
(iii) Determination of Hydrometer test. per test 3
(iv) Determination of liquid limit test.
(a) 3 points. per test 2
(v) Determination of Plastic Limit test. per test 3
(vi) Determination of Moisture Content test. per test 2
(vii) Determination of bulk density test. per test 3
(viii) Determination of Specific Gravity test of fine grained per test
soil. 2

(ix) Determination of Direct shear strength.


(b) 2 Points. per test 2
(x) Determination of the shear strength parameters of a
specimen tested in unconsolidated undrained traiaxial
compression test without measuring pore water pressure,
by triaxial test.

(b) 2 Points. per test 1


(xi) Determination of consolidated drain test determination
of the shear strength parameters of a specimen tested in
consolidated drain traiaxial compression test without
measuring pore water pressure, by triaxial test.

(b) 2 Points. per test 1


(xvi) Determination of the shear strength parameters of a
specimen tested in consolidated undrained traiaxial
compression test without measuring pore water pressure,
by Triaxial test.

(b) 2 Points. per test 4


D. Transportation on charges for boring.
(i) Hire charge. per day 3
(ii) Fuel. per km 138

----------------------------------
Sample Format of Bank Guarantee