You are on page 1of 5

38/6, K. M.

Stone, Delhi-Jaipur Highway, Narsingpur, Gurgaon -122 001 (Haryana) India


Ph.: +91-124-4129254, Fax: +91-124-4129751/52
E-mail: lab@sunbeamauto.com URL : sunbeamlabs.com

AUTO PVT, LTD,


TESTING, RESEARCH & DEVELOPMENT CENTRE
Certificate No.
TEST CERTIFICATE

Party Name: SPIROTECH HEAT EXCHANGERS Date: 15/01/2019 Job Order No. : 812-010-1770
A-45,46S51,52KAHRANI
INDL.AREA.BHIWADI EXTN Reference No.:
DISTT.ALWAR-301019
Date: 28.12.2018

Sample Particulars : ONE SAMPLE OF AL.SHEET 1.6MM MARKED AS ZHEJIANG GKO AL WAS RECEIVED.

RESULTS
ULR - TC676418000005414P
Chemical Analysis
By Emission Spectrometer (Protocol: Technical Manual)
Element %

Copper 0.012
Magnesium 2.803
Silicon 0.087
Iron 0.341
Manganese 0.040
Nickel 0.003
0.031
0.002
Tin 0.022
Titanium 0.010
Chromium 0.158
Calcium 0.0013
Stronsium 0.0000
Aluminium 96.448

ELV Test Report:


Element Observed Protocol

Lead 28 PPm AAS


Cadmium 5 PPm AAS
Mercury < 1 PPm AAS
Hexavalent Chromium <1PPm 130:3613

Test As Per IS : 1608 : 2018

Physical Test Observed

Tensile Strength (N/mm2) 224


Yield / 0.2% Proof Stress (N/mm2) 168
% Elongation (GL=50mm) 12.6

Test As Per IS : 1501: 2013

Micro Hardness (HV0.1) 35

*""End of Result*

1. Sample wilt be retained only for one month.


2. The results listed refer only to the tested samples and applicable parameter.
Endorsement of product is neither inferred nor implied.
3. Total liability of our works is limited to invoiced amount.
38/6, K. M. Stone, Delhi-Jaipur Highway, Narsingpur, Gurgaon -122 001 (Haryana) India
Ph.: +91-124-4129254, Fax: +91-124-4129751/52
E-mail: lab@sunbeamauto.com URL : sunbeamlabs.com

AUTO PVT. LTD.


TESTING, RESEARCH & DEVELOPMENT CENTRE
Certificate No.
TEST CERTIFICATE

Party Name : SPIROTECH HEAT EXCHANGERS Date: 15/01/2019 Job Order No. : 812-010-1769
A-45,46&51,52KAHRANI
INDL.AREA.BHIWADI EXTN Reference No.:
DISTT.ALWAR-301019
Date: 28.12.2018

Sample Particulars : ONE SAMPLE OF AL.SHEET 1.5MM MARKED AS HINDALCO WAS RECEIVED.

RESULTS
ULR - TC676418000005413P
Chemical Analysis

By Emission Spectrometer (Protocol: Technical Manual)
Element

Copper 0.041
Magnesium 0.008
Silicon 0.103
Iron 0.472
Manganese 0.000
Nickel 0.003
0.020
0.002
Tin 0.003
Titanium 0.006
Chromium 0.001
Calcium 0.0025
Phosphorus 0.0049
Stronsium 0.0000
Vanadium 0.002
Aluminium 99.305

ELV Test Report:


Element Observed Protocol

Lead 25PPm AAS


Cadmium 4PPm AAS
Mercury <1 PPm AAS
Hexavalent Chromium <1PPm ISO: 3613

Test As Per IS : 1608 : 2018

Physical Test Observed

Tensile Strength (N/mm2) 109


Yield / 0.2% Proof Stress (N/mm2)
% Elongation (GL=50mm)

Test As Per IS : 1501: 2013

Micro Hardness (HV0.1) 35

***"End of Result*"**

1. Sample will be retained only for one month.


2. The results listed refer only to the tested samples and applicable parameter.
Endorsement of product is neither inferred nor implied.
3. Total liability of our works is limited to invoiced amount.
38/6, K. M. Stone, Delhi-Jaipur Highway, Narsingpur, Gurgaon -122 001 (Haryana) India
Ph.: +91-124-4129254, Fax: +91-124-4129751/52
E-mail: lab@sunbeamauto.com URL : sunbeamlabs.com

AUTO PVT LTD.


l
i
11
TESTING, RESEARCH & DEVELOPMENT CENTRE Certificate No.
TEST CERTIFICATE

Party Name : SPIROTECH HEAT EXCHANGERS Date : 15/01/2019 Job Order No. : 812-010-1760
A-45,46&51,52KAHRANI
INDLAREA.BHIWADI EXTN Reference No.:
DISTT.ALWAR-301019
Date: 28.12.2018

Sample Particulars : ONE SAMPLE OF Sm.AL TUBE MARKED AS 9.52MMX0.71 (GHANGZHOU GRANA) WAS RECEIVED.

RESULTS
ULR - TC676418000005412P

Chemical Analysis
By Emission Spectrometer (Protocol: Technical Manual)
Element %

Copper 0.069
Magnesium 0.010
Silicon 0.151
Iron 0.610
Manganese 1.013
Klirkpl
INICK6I 0.006
Zinc
~'™ 0.031
LGdu 0.003
Tin 0.002
Titanium
T-'a. ' _
0.029
Chromium 0.008
Calcium n (\C\AA
U.UU44
Phosphorus 0.0032
Stronsium 0.0000
Vanadium 0.017
Aluminium

Test As Per IS: 1608: 2018


«-*u
Observed

Tensile Strength (N/mm2; 114

Yield / 0.2% Proof Stress (N/mm2) 76

% Elongation (GL=50mm;

Test As. Per IS : 1501: 2013


"

Micro Hardness (HV0.1)

1. Sample will be retained only for one month. MunishKaushik


2. The results listed refer only to the tested samples and applicable parameter. . Sr. Manaer
Endorsement of product is neither inferred nor implied. . Auth
3. Total liability of our works is limited to invoiced amount.
38/6, K. M. Stone, Delhi-Jaipur Highway, Narsingpur, Gurgaon -122 001 (Haryana) India
Ph.: +91-124-4129254, Fax: +91-124^1129751/52
E-mail: lab@sunbeamauto.com URL : sunbeamlabs.com

AUTO PVT. LTD.


TESTING, RESEARCH & DEVELOPMENT CENTRE
Certificate No
TEST CERTIFICATE

Party Name : SPIROTECH HEAT EXCHANGERS Date: 15/01/2019 Job Order No. : 812-010-1759
A-45.46&51.52 KAHRANI
INDLAREA.BHIWADI EXTN Reference No. :
DISTT.ALWAR-301019
Date: 28.12.2018

Sample Particulars : ONE SAMPLE OF Sm.AL TUBE MARKED AS 7MMX0.51 (GHANGZHOU GRANA) WAS RECEIVED.

RESULTS
ULR - TC676418000005411P
Chemical Analysis
By Emission Spectrometer (Protocol: Technical Manual)
Element

Copper 0.096
Magnesium 0.005
Silicon 0.158
Iron 0.498
Manganese 1.012
Nickel 0.005
Zinc
Lead 0.004
Tin 0.006

Chromium 0.011
Calcium 0.0033
Phosphorus 0.0035
Stronsium 0.0000
Vanadium 0.018
Aluminium

ELV Test Report:


«

Lead
Cadmium 7 PPm
Mercury < 1 PPm AAS
Hexavalent Chromium < 1 PPm ISO : 3613

Test As Per IS : 1608 :2018

Physical Test
1^1 • t T

Observed
I \l-*, , . . , , - . r i

Tensile Strength (N/mm2) 117


Yield / 0.2% Proof Stress (N/mmz) 61
% Elongation (GL=50mm) 38.0

Test As Per IS : 1501: 2013

Micro Hardness (HV0.1)

'End of Result*****

1. Sample will be retained only for one month.


2. The results listed refer only to the tested samples and applicable parameter.
Endorsement of product is neither inferred nor implied.
3. Total liability of our works is limited to invoiced amount.
38/6, K. M. Stone, Delhi-Jaipur Highway, Narsingpur, Gurgaon -122 001 (Haryana) India
Ph.: +91-124-4129254, Fax: +91-124-4129751/52
E-mail: lab@sunbeamauto.com URL : sunbeamlabs.com

AUTO PVT LTD.


i1q IU
n qIU
n qI
TESTING, RESEARCH & DEVELOPMENT CENTRE
Certificate No
TEST CERTIFICATE

Party Name : SPIROTECH HEAT EXCHANGERS Date: 15/01/2019 Job Order No.: 812-010-1758
A-45,46 & 51,52 KAHRANI
INDLAREA.BHIWADI EXTN Reference No.:
DISTT.ALWAR-301019
Date: 28.12.2018

Sample Particulars : ONE SAMPLE OF Sm.COPPER TUBE MARKED AS DIA 9.52X0.30 (TOAN PHAT) WAS RECEIVED.

RESULTS
ULR - TC67641800000541 OP
Chemical Analysis
By Emission Spectrometer (Protocol: Technical Manual)
,-. n/
Element %

Tin 0.008
0.010
0.007
Iron 0.020
Aluminium 0.001
Nickel 0006
Silicon 0.000
Manganese n nnn
0.000
Bismuth 0.0010
Antimony 0.000
Chromium 0.000
Sulphur 0.004
Phosphorus 0.014
Silver 0.001
Berryllium 0.0000
Cadmium 0.002
Cobalt 0.000
Copper 99.922

ELV Test Report:


Element Observed Protocol

Lead 25 PPm AAS


Uadmiui
Cadmium 3 PPm AAS
Mercury < 1 PPm AAS
Hexavalent Chromium < 1 PPm ISO : 3613

Test As Per IS : 1608: 2018

Physical Test Observed

Tensile Strength (N/mm2) 238


Yield / 0.2% Proof Stress (N/mm2) 142
% Elongation (GL=100mm)

Test As Per IS : 1501 : 2013

Micro Hardness (HV0.1)

""•End of Result***
1. Sample will be retained only for one month.
2. The results listed refer only to the tested samples and applicable parameter.
Endorsement of product is neither inferred nor implied.
3. Total liability of our works is limited to invoiced amount.

You might also like