Project Job no.

Calcs for Start page no./Revision


4
Calcs by Calcs date Checked by Checked date Approved by Approved date
F 20/06/2017

Strip 1 87.4 0.0 10598327 9.6 11.4 PASS


Strip 2 129.1 0.0 11488573 8.2 13.4 PASS
Strip 3 21.0 0.0 7773739 9.6 7.7 FAIL

Load combination 2 - [1.2 DL + 0.4 LL + 1.0 WL]


No. Ultimate Primary MI of cracked Combined Design Design
moment section moment
load moment strength status
(check
Pu M ua Icr Mu M n - Mu
(kN) (kNm) (mm 4 ) (kNm) (kNm) Vs.
M n )
Strip 1 87.4 3.6 10598327 34.5 11.4 FAIL
Strip 2 129.1 4.8 11488573 8.2 13.4 PASS
Strip 3 21.0 3.6 7773739 9.6 7.7 FAIL

Load combination 3 - [1.0 DL + -1.0 WL]


No. Ultimate Primary MI of cracked Combined Design Design
moment section moment
load moment strength status
(check
Pu M ua Icr Mu M n - Mu
(kN) (kNm) (mm 4 ) (kNm) (kNm) Vs.
M n )
Strip 1 72.8 3.6 10026969 17.0 10.6 FAIL
Strip 2 107.6 4.8 10810314 8.2 12.3 PASS
Strip 3 17.5 3.6 7608846 9.6 7.5 FAIL
Check for area of steel for double layer reinforcement w all (AS 3600, cl. 11.6.1)
Area of vertical steel provided; A st_v = 226 mm 2
Min area of ver steel required; A st_v_min = 135 mm 2
Max area of ver steel limited; A st_v_max = 3600 mm 2
PASS - Provided vertical steel is greater than minimum required
PASS - Provided vertical steel is less than maximum allowable

Area of hori steel provided; A st_h = 3732 mm 2


Min area of hori steel required; A st_h_min = 225 mm 2
Max area of hori steel limited; A st_h_max = 3600 mm 2
PASS - Provided horizontal steel is greater than minimum required
FAIL- Provided horizontal steel is greater than maximum allowable

Slenderness check (AS 3600, cl. 10.5)


Maximum slenderness ratio limit; s r_max = 120
Radius of gyration; r min = 0.3  L w = 45 mm
Effective height factor; k = 1.000
Actual slenderness ratio; s r_act = k  H wu / rmin = 111.1
PASS - Wall slenderness ratio is less than maximum permissible