You are on page 1of 26

DEPARTMENT OF FOOD TECHNOLOGY

LAB REQUISITION

FOOD CHEMISTRY LAB


Approx.
Sl. Name of the Quantit
Specification(Updated version) amount
No Equipment y
(Rs.)
Microprocessor based digital temperature controller, Casted
Aluminium Alloy Heater, 65 to 80% solvent recovery,
Independent loading of sample with individual mechanical
controls. Unique upward spring loaded movement of
individual block for perfect leak proof alignment Safety.
Soxhlet Auto over temperature protection, auto Sensor break
100000.00
1 apparatus protection, Auto Error Indication, etc. Inbuilt Air pump with 1
(automatic) Stainless steel manifold for perfect removal of solvent cloud.
Six Place Automatic Solvent Extraction System with auto
time temperature programming facility and auto phase change
over with PC compatibility feature.
Temperature range should be upto 200degree
Fume hood should be provided with equipment
Capacity: 10-100 μl and 100-1000 μl, Autoclavable digital
Micro Pipette, Advanced durability against organic solvent
2 Pipette dispensing, Resistant to organic solvents. Fully autoclavable, 5 each 2000.00
Easy-Calibration function, One-touch locking mechanism to
lock the sample volume.
1. High Pressure Binary Gradient HPLC Liquid Pump – 1 No
Flow Range: 0.000 to 10.000ml, in 0.001ml/min
increments,
Flow Precision of 0.1% RSD or 2 seconds SD
Operating Pressure upto 6000psi, throughout entire Flow
Range.
Flow Accuracy : + 1.0% of setting
Compositional Accuracy: + 0.5%
Precise stepper motor driven Non – Circular Gear Piston
Drive
Dual Reciprocating Pistons to Provides Pulse free Solvent
Delivery, and piston self-centering mechanism
11 Gradient Profile in-built, to make easy to select the
3 HPLC 1 150000.00
Gradient curves for HPLC analysis
2. Photo Diode Array Detector – 1 No :
Wavelength Range : 190 – 800 nm
Noise specification : 10 x 10-6 AU, 10mm cell at 254nm,
Drift specification : 1 x 10-3 AU/hour
Detector linearity = 5% at 2 AU Propyl Paraben, 257 nm
512 element photodiode array device
Operate in 3D or 2D mode, Operation as multi-wavelength
detector, in 2D data in 2D mode, up to maximum of 8
chromatograms in 2D mode Full spectral analysis and
collection of 3D data in 3D mode
Lamp Optimization software to ensure and Guarantee low
noise performance in visible range to 800nm without lamp
change, also Compensates for lamp degradation over time
without change in optical bandwidth and hence linearity
performance
Should have “Taper-Beam” flow cell for RI and stray light
effects and optimizes light throughput without absorbance
subtraction corrections and data manipulation.
Should have peak purity algorithm for automatic correction
for noise.
3. Manual Injector -1 No
With mounting plate, 20uL syringe
4. Column – 1No
Column C-18, 250, 4.6 X 5u,
Column C-8, 250, 4.6 X 5u
5. Column Heater.
Set Point Temperature Range : Amb – 1200C ( and above)
Temperature Accuracy: + 1.00C
Column Capacity : upto three Columns with Guard Column
6. Multi-channel Fluorescence Detector - 1 No:
Excitation Wavelength Range: 200-890 nm.
Emission Wavelength Range: 210-900nm.
Bandwidth: 20 nm
Accuracy: +/-3 nm
Reproducibility: +/-0.25 nm
Variable Emission Units Full Scale 1 – 100,000
Measurement Range: 0.0001 (at 1 EUFS) to 100,000.0000
EU (at 100,000 EUFS).
Programmable 2000 hour lamp on/off and front panel lamp
operation serial number, hours and ignitions display.
Programmable contact closure outputs (2) to fraction
collectors, etc. can be activated by time, absorbance threshold
or ratio criteria.
Stand-alone programmability, Stores up to 10 user-defined
programs (or methods) consisting of up to 48 programmable
timed events and 2 threshold events each.
Single or multi-channel Monitors fluorescence at one or
more discrete wavelength pairs.
Should have Integral erbium for calibration reference to
Ensures wavelength accuracy.
Should support Spectrum scan storage, display, subtraction,
storage, and playback, in addition to standard tunable
fluorescence functionality.
Should have full diagnostic capability, Supports built-in
diagnostic tools to optimize functionality and performance.
Should have Axially Illuminated Flow Cell to ensure low
dispersion with a volume of 8μL and a long 5mm Excitation
path length.
Should have Orthogonal optic design provides 90º between
excitation and emission benches in 2 planes - eliminates stray
light problems.
Detector should come as standard with integral erbium
(NIST traceable) filter for wavelength verification at power up
or on-demand. Checks Excitation and Emission gratings and a
full suite of qualification methodologies. “Emission Units” and
“Normalization”
Should have In-Built User diagnostic function to
automatically calculate the ASTM value for Signal to Noise
for Raman band of Water.
Ultimate sensitivity of Raman S/N of >800 with low
dispersion 8μL flow cell.
Should have Scanning capability with programmable scan rate,
automatic blank subtraction and scan storage. Front panel scan
display includes annotation of spectral wavelength maxima. 7.
Differential Refractive Index Detector –1 No
Refractive Index Range: 1.00 to 1.75 RIU
Noise Level: + 1.5 X 10e (-9) RIU mode
Flow Cell: Fused Quartz
Flow cell Volume: 10 Microlitre, Thermostated
Drift : < + 1.0 X 10e(-7) RIU /hour
Programmable functions of range, auto Zero and auto
purging
Automatic Back Pressure valve to protect flow cell,
8. Chromatography Data Station : Control, acquire and process
date
Oracle Database, 32 Bit Software should control Photo
Diode Array Detector, Fluorescence Detector, and Refractive
Index Detector ( Should control all the above modules)
Interactive control and display of solvent delivery
All functions and features accessible from a single window-
use the command bar to navigate
Wizards to simplify and automate common system
functions.
Methods – instrument, processing and reporting parameters
in one place.
Oracle database for better organization and easy retrieval or
work and System user data.
Diagnostics functions and configuration wizards
Extensive user help
9. Instrument required UPS 10KVA 10.Instrument should be
compatible and be provided with computer, Laser printer and
necessary software and UPS 1KVA for computer.
Load Cell: 5, 30, 50, 100, 250, 500, and 750 kg.f, Load
Accuracy: ± 0.5% of reading down to 1% of load cell capacity,
Maximum Speed: 20mm/sec at 500Kg.f, Maximum return
speed: 0.01 mm/sec, Speed/drive Accuracy: better than 0.1%,
Range Setting: 0.01 to 524 mm, Range Resolution: 0.001mm,
Operating Modes: Measurement of Force and Distance in
Tension, Compression, Shear, Extrusion, etc. Data Channels:
Texture Filtered force at 20 bit. Distance at 24 bit. Unfiltered force at
4 1 500000.00
analyzer 16 bit. Two linear analogue inputs (range±-4.5v @ 16bit) or
PT100 temperature probe inputs (Range -50˚C to +250˚C),
Filtered force: Oversampled at 8000 samples per second and
digitally filtered to 500 pps at 20 bit resolution, Operating
Temperature: 0 to 40˚C, Operating environment: Laboratory
conditions, interface to PC through a standard RS232 serial
port, Power supply: Universal mains input voltage, Software,
complete database of family of probes and attachments,
external devices like temperature/ humidity etc. Heavy duty
Platform. Platform for samples and Instrument should be
compatible with computer, printer and all peripherals. It
should contain all probes for measuring texture properties of
all food material. Instrument should be compatible and be
provided with computer, Laser printer and necessary software
and UPS 1KVA.
Instrument for automatic determination of the oxidative
stability of biodiesel (fatty acid methyl esters, FAME).
Conductometric indication. Instrument for 230 V and 50...60
5 Rancimat 1 15000.00
Hz. Instrument should be compatible and be provided with
computer, printer and necessary software. Extra sample holder
should be made available.
1. Fully Automatic Kjedahldigestion,distillation,titration and
calculation system for analysis of Nitrogen/Protein.
2.Digestion unit (minimum 12 tubes)with IR or electric
heating facility, preferably programmable. 3. Fully
programmable with suitable software. 4.Titration may be
potentiometric/colorimetric titration system. 5.The system
must have maximum safety features to avoid any possible
Kjedahl unit accident and should have fully covered automatic safety door.
6 (protein & 6. Self adjusting cooling water control to save water(intelligent 1 15000.00
nitrogen) cooling water control adjust the flow according to temperature
minimizing water consumption 7 cost. 7. Variable output
system generator to provide the flexibility to analyse volatile
parameters other than nitrogen. Interchangeable burette for
easy switching of titrant strengths. 8. Automatic tube
drainage.Alkali resistant splash head and tube drain vessel for
long lifetime. 9. Must have data transfer facilities to PC
through machine.
The kit contains all of the materials needed for running the
Colum columns like glass colum, Silical gel for Colum
7 Chromatograp chromatography, glass wool, Colum stand, sample mixture, 1 15000.00
hy& kit disposable pipettes, buffer, collection tubes, with all
accessories
SS 304 grade working table with sink and tap, Size: 8 1/2‟ x 4
8 SS Table 8 120000.00
½‟ ht= 4 ft with Top and bottom: 2 mm
Consisto-
9 Sample 50-100ml; RPM 1-100; temp 0-100oC 1 5000.00
meter
TOTAL 922000.00
FOOD PACKAGING LAB
Approx.
Sl. Name of the Quantit
Specification amount
No Equipment y
(Rs.)
1 Electronic balance Range 0-200g Accuracy- 0.001 g 1 15000.00
2 Taber Stiffness Tester Range:
Range:
0-1000
0-1000
N N 1 12000.00
Folding Endurance Range : up to 5000 N
3 1 80000.00
Tester
4 Cobb Tester 100 ml & 200 ml Capacity Fabricated 1 20000.00
5 Elmendorf Tear tester Range: up to 6000 N 1 30000.00
Smoothness &
6 Range up to 500 ml per sec 1 10000.00
Porosity Tester
Mullen Bursting
7 Range (up to 7-35 kg per sq.cm) 1 30000.00
Strength Tester
Compression Strength Capacity up to 1000 kg Accuracy 0.01 kg
8 1 20000.00
Tester
9 Mechanical Drop Test Range up to 3 mtr.ht 1 5000.00
Oxygen Head Space Up to 100 bar
10 1 15000.00
Analyzer
Vacuum Leakage Up to 20 bar
11 1 20000.00
Tester
12 Torque Tester Up to 200 Nm 1 2000.00
Oxygen Head Space Up to 100 bar
13 1 40000.00
Analyzer
Platinum Dish or Up to 100 ml Capacity
14 1 3000.00
borosilicate dish
15 Electronic balance Capacity about 2000 g / Accuracy- 0.01 g; 1 5000.00
Desiccators for RH Borosilicate Temperature Range 5 0C to 50 0C
16 1 50000.00
Climate Chamber
Load cell 10N, 5 kN, 100 kN. Instrument should be
Universal testing
17 provided with all other accessories, probe, fixtures, 1 100000.00
Machine
peripherals like computer and printer
18 WVTR Tester Up to 0.0001 g/m2; High automatic control system, 1 50000.00
Temperature range: -140-6000C, Heating rate: 0.10C
Differential scanning
19 to 1000C/min resolution range upto: 0.2 to 1uW, 1 100000.00
calorimeter
calorimetric accuracy: 0.05% .
Press Range upto: 70 Kg/Cm² Pressure Indicator &
Hydro Statics Pressure Controller: Gauge Accuracy: 1% FSD Power Supply:
20 1 30000.00
Tester 230 V AC, 50 Hz Dimension (Inch): 24 X 25 X 45
Net Weight: 55 kg
TOTAL 637000.00
FOOD ENGINEERING LAB
Approx.
Sl. Name of the Quantit
Specification amount
No Equipment y
(Rs.)
Capacity 2 lit with DO, pH; O2 sensors; temp
1 Bio Reactor 1 80000.00
sensors; rpm in-situ
2 Micro filter 0.05μm-0.1 μm with SS cover plate 1 5000.00
3 Ultra-filter 0.05nm-0.1nm with SS cover 1 5000.00
Jaw crusher for grains for making flour Lab scale
Jaw crusher for grains
4 model Capacity about 5 kg/h 1 50000.00
for making flour
Roller crusher for Roller crusher for grains for making flour Lab scale;
5 1 50000.00
grains for making flour capacity about 5kg/h
Temperature Range is from +5C to +94 OC and RH -
6 Humidifier 1 20000.00
20 to 98%.
Range 150lpm; clarity level up to 10mg/lit; fluid
7 Vacuum rotary filter viscosity up to 20cp and vacuum pump is attached 1 20000.00
with this.
Lab model Vapor Compression Refrigeration Cycle
with all the necessary accessories like temperature,
8 Refrigeration Tutor 1 50000.00
pressure indicator, control valve control panel
humidity controller
TOTAL 280000.00
FOOD MICROBIOLOGY LAB

Approx.
Sl. Name of the Quantit
Specification amount
No Equipment y
(Rs.)
Cabinet(Material of construction):
Laminar Air Flow Cabinet should have fully enclosed bench
designed.
The Laminar flow bench should have Stainless Steel SS 304
table with MS coated tabular frame and body.
Laminated Unit should also have stand by control system with
lock and key.
Unit:
Door should be made of tempered safety glass sliding door or
glass wind screen.
Should have LCD display to show measured parameters like
stage velocity, total using time, UV/FL lamp on/off etc.
Unit should have Differential pressure indicator.
Cleanliness level :
CLASS 100 (ISO 5 for particle sizes 0.5 μ < 3530 particles/M³
of air at both at Rest & Operation Condition as per ISO 14644
–1.
Working size: 4 ft x 2 ft x 2 ft.
Work table: It should have IS 304 Grade Stainless Steel with
finish 4 polish surface Front door, 5 mm thick clear Acrylic
Sheet - Vertical sliding.
Direction of flow: Horizontal.
Airflow Speed: Velocity should have 90 Feet/Minute ± 20.
Laminar Air Blower Assembly: It should have one set blower system,
1 01 100000.00
Flow which consists of dynamically & statically balanced
aluminium centrifugal impeller driven by 1/4 HP, single
phase,1200- 1400RPM motor, enclosed in an PU coated GI
casing suitably suspended in a pair springs & connected to the
filter chamber through flexible canvas duct.
HEPA Filters:
Size: 30” x 18” x 3”
Type: Separator less type, Mini-Pleats HEPA Media
Media: Ultra clean glass fiber paper
Retention: 0.3 Micron
Efficiency: 99.997%
Initial Pressure: 16 mm WG, Grade: H13 rating.
Pre Filters:
Size : 600 x 300 x 65 mm
Media : Synthetic, non-woven polyester
Casing : Epoxy painted GI frame
Retention : 10 Micron & above
Efficiency : 90%
Initial Pressure: 6 mm WG
Grade : F7 rating
Particle Retention: 0.3 Micron.
Noise level:<60 dBA±5.
Power Supply: Power supply should have 220-230 V, 50 Hz.
And all components UL listed and CE marked.
Illumination: Fluorescent tube 1 no.
Light: High intensity, low wattage >800 lux,
Pre-mounted UV lamp (30 W) with separate switch.
UV lamp: It should be 15 Watts, Equivalent to Philips make,
1½ Feet length, – 1 No. each.
Other accessories:
 5/15 Amp power point, Gas inlet, Levelling Screws &
Castor Wheels
 Side mounted double electrical socket for ancillary
equipment operation
 DOP test port
 Easily changeable pre-filters
 Fitted with UV Germicidal lamp for sterilization.
 Fitted with Acrylic Front Door sliding type
 Fitted with Manometer for Measurement of HEPA
Filters Choking system.
 Fitted with Cock for Gas Connection.
 Ensure noiseless operation and anti-vibration
construction provides efficient working environment.
 Filter replacement warning signal.
Body: Binocular, sturdy, stable base body with focus
adjustment controls.
Eye piece:
- It should be Paired, high quality, (the image of the object as
seen through the binocular eyepiece should be well defined
centrally in at least 2/3 field of view).
-Achromatic, wide field, 10 x with inbuilt pointer.
-The eyepiece should be aplanatic and have a minimum field
number of 18 Diopter adjustment must be present on one/ both
eye pieces or on the eye piece tube.
Optical system:
- Optical system should be infinity corrected.
- System complete with illumination system is required.
Objective:
-Three objectives 10x, 40x, 100x.
-10x and 40x objectives should have numerical apertures of
Binocular
2 0.25 and 0.65 respectively. 01 50000.00
Microscope
-100x should have numerical aperture of 1.25 and should be
of oil immersion.
-Unbreakable containers to be provided for storing the
objectives. All objectives should be wide field, achromatic
and par focal.
Nose piece: Revolving nose piece to accommodate a
minimum of three objectives with click stops. It should be
provided with ribbed grip for easy rotation mounted on a
precision ball bearing mechanism for smooth and accurate
alignment. Extra ports if any should be fitted with dust proof
metallic/ebonite caps.
Stage:
-Stage uniformly horizontal, mechanical stage having
dimensions of length 140 mm (+/- 20mm) with fine vermier
graduations (minimum reading accuracy of 0.1 mm).
- It should be designed with convenient sub-stage vertical
coaxial adjustment for slide manipulation.
-The stage should have ball-bearing arrangement to allow
smooth travel in transverse directions i.e. 80 mm (+/-5mm)
and front to back direction, 50mm (+/- 5mm).

Sub-stage condenser: Abbe-type condenser with numerical


aperture (N.A.) 1.25 focusable with rack and pinion
arrangement incorporating a spherical lens and an iris-
diaphragm.
Sub-stage illuminator:
-The system should have a build-in variable light source
(Illuminator).
-This light source should have a 20 W, 6 V Halogen lamps.
-The system should be provided with a step down transformer
and an on-off switch and intensity control.
- The lamp should be provided with a lamp socket which has
the facility for easy replacement of the bulb.
Power supply:
-Voltage 220 V AC, 50Hz. should have one on-off power
switch
- A plano-concave mirror in fork mounting should be supplied
which would be attachable to the base for field use when
power is not available.
Unit:
-All optical parts including objectives, eye pieces and prisms
should have anti-reflective coating which also gives anti-
fungal property.
- All metallic parts should be corrosion-proof, acid proof and
stain-proof.
- Working manual should be provided with each microscope.
- A bottle of at least 25 ml immersion oil, a roll of lens tissue
paper and lens cleaning solution (100 ml) should be provided
with each microscope.
- One anti-static cleaning brush should be provided with each
Microscope for cleaning purpose.
-The unit shall be capable of being stored continuously in
ambient temperature of 0 -50 deg C and relative humidity of
15-90%.
Digital camera:
3 megapixel scientific grade (even at dim light) colour CCD
camera along with image capture and analysis software and c-
mount adapter.
-Resolution at least 2448 x 1920 effective pixel (4 x 4 bining
and 2 x 2 bining) and 10 bit digitization.
- Microscope should come along with PC (i5 6200U
processor, 6 GB RAM, 500GB HDD, DVR R/W, LED 20”).
With UPS (minimum offline backup of 30 minutes).

Optical Design:
UV-VIS -Double Beam with sample and reference cuvette positions;
3 Spectrophoto Czerny-Turner Monochromatic 01 250000.00
meter - Reference Compartment Should accommodate cells up to
100 mm path length as standard feature.
Light Source:
Instrument should have 2 sources i.e.
(1) Halogen lamp for Visible range
(2) Deuterium Lamp for UV range, light source should be auto
automatically selected as per wavelength required.
Spectral Bandwidth: 0.2 to 5 nm Variable bandwidth.
Detector: Instrument should have high sensitive
Photomultiplier tube as a detector.
Scan Ordinate Modes: Absorbance, % Transmittance, %
Reflectance.
Scan Ordinate Modes: Absorbance, % Transmittance, %
Reflectance.
Resolution: Resolution: 0.1nm or better.
Wavelength Range: 190-900 nm Wavelength.
Wavelength Accuracy: ± 0.3nm for entire range.
Wavelength Repeatability: ± 0.05nm or better± 0.8 nm.
Scanning Speed: Instrument should have variable wavelength
scan rate from 4000 to 0.5nm/Min with automatic selection.
Photometric Range: Absorbance = -4.0 to 4.0 Abs or better.
Transmittance & reflectance 0 to 80000 % or better.
Photometric Accuracy: 0.5 A: ± 0.004A; 1A: ± 0.006A; 2A:
± 0.010A; (440 nm; traceable neutral density filters).
Stray Light: Max. 0.005% (220 nm Nal) or better, Max.
0.005% (340,370 nm NaNO2) or better Max. 1% (198nm
KCI) or better.
Noise: 0.00005 Abs RMS (500nm) or better.
Drift:< 0.0005 A/hr (500 nm, 1 hour warm-up).
Baseline flatness: ± 0.0005 Abs or better.
Accessories:
-Instrument should have large sample compartment with
suitable facility to fit below accessories. (Supplier should
quote for same in the offer)
(i) Quartz cell 10 mm Rectangular Path Length (5pairs)
(ii) Quartz Cell 50mm Rectangular Path Length (2 Pairs)
(iii) Quartz cell 100 mm rectangular Path Length (2 pairs).
- Film Holder for measurement of direct transmittance of
films.
Operational Requirements:
It should have
- Microprocessor based single pan analytical balance with high
accuracy and precision.
- Reading of the weight by digital display
- Electronic top loading balance with transparent case.
- The balance should have functions of piece counting, percent
Analytical weighing, and formulation, dynamic.
4 01 17000.00
Balance. - Weighing with automatic and manual start and provision for
data interface.
Technical Specifications:
- Weigh accurately up to 3rd decimal place.
- Fully automatic time and temperature controlled internal
calibration and balance should be capable to adjust itself Auto
zero setting.
- Weighing capacity up to 200g
Readability 0.001gm Repeatability 1mg or less.
Setting time 1.5secs.
Balance should have: - Liquid Crystal Display (LCD) for
display and Stainless steel square weighing pan
- IR sensors for hands free operation
- Alphanumeric data entry of 4ID’s
Environmental factors: -Safety for electromagnetic
compatibility.
- The unit shall be capable of operating in ambient temperature
of 20-30 deg C and relative humidity of 80%.
Power supply: -Power input to be 220-240VAC, 50Hz.
- Suitable UPS with maintenance free batteries with minimum
one hr backup should be supplied with the system.
Accessories:All necessary accessories should be provided
with unit.
Material of construction: Full Stainless steel fabricated body
with duly heat cured epoxy coating with dimensions 41x32x30
cm.
Unit:
It should consist of
- Digital dispayupto 4 digits.
Colony - count range from 0 to >9000
5 01 6000.00
counter - It should consist of Magnifying lens (more than 2X
magnification. with digital marking pen(1)
- Accepts petridishupto size 120mm diameter with a centering
adaptor for standard 90mm petri dish
- Fluorescent LED lamp
- Zero reset button.
Warranty:2 yrs of warranty with working manual.
Counting Chamber:-Includes Cover slips (5080 and 5090
-All glass construction.
Howard
- It should consist of Engraved lines for microscopic
6 Mold 01 6000.00
calibration.Dimensions:
Counter
Glass slides of 75 x 35 mm, with central section 15 x 20 mm
which provides a cell of 0.1 mm depth.
Base unit:-Table-top high speed refrigerated centrifuge with
option of fixed angle as well as swing out rotors.
-Should give max Speed of 14,000 rpm/max rcf of 20,000xg
or above with fixed angle rotor.
- Rotor imbalance checking and imbalance alarms should be
present
- Should be compatible with rotors for small volume (1.5
ml/2.0 ml) as well as large volume (at least 4X100 ml).
Cooling - LCD digital display for RPM/RCF, timer and temperature
7 01 100000.00
Centrifuge setting and actual run conditions should be displayed.
Temperature range:5ºC to 40 ºC.
Power requirement: 220 v to 240 v -50 Hz If a voltage
stabilizer is required, it should be supplied along with the unit.
Rotors:-Fixed angle rotor: Fixed angle rotor for 1.5/2.0 ml
tubes (at least 28 places or more)
- Should supply adapters for 0.5 and 0.2 ml tubes
-Should give RCF of 20,000 X g or more.
- Rotor should be autoclavable.
- Swing out rotor: Should have at least 4× 100 ml of capacity.
- Maximum RCF produced should be 3200 x g or above
-Four buckets should be provided (either round or
rectangular buckets)
-Adapters for 15ml conical bottom centrifuge tubes & 50 ml
conical bottom centrifuge tubes should be provided (two
adapters for 6 or 8 X15 ml and two adapters for 2 or 4×50 ml).
- Rotor and buckets should be autoclavable.
- Fitted with certified aerosol type cap on the rotor to avoid
any accident due to breakage of sample tubes.
Warranty:3 years comprehensive warranty.

Unit Assembly:
-Assembly should consist of borosilicate glass funnel with
funnel base, filter support with silicone stopper clamp
- It should have Holder which should be autoclavable.
- It should be PTFE-Faced Fritted Glass Support.
- Having diameter to hold filter paper of the 47mm diameter.
Micro
Assembly:Assembly should be classic glass fitted holder with
8 Filtration 01 7000.00
fitted inlet as funnel.
Unit
Funnel capacity:It should be Available in four graduated
funnel capacities 100, 300, 500,
Filter pore size:It should consists of vacuum pump with PVC
tubing.
- Should consist of side arm flask (minimum 1 liter capacity)
- Forceps to handle filter paper (sharp edged).
Ph Range:0 - 14.00
Ph Accuracy:± 0.01 Ph
Mv Range:0 - ± 1999
Mv Accuracy:± 1mV
Temperature Range:0 – 100 oC.
Temperature Accuracy:± 1 0C.
9 pH meter Calibration Points: 3-point calibration with auto buffer 01 5500.00
recognition.
For calibration, preprogrammed buffer sets should be supplied.
Temperature Compensation:Automatic
Display:Backlit blue LCD with operation icon.
Power:9V DC.
Dimensions (L X W X H):210×205×65 mm.
Capacity: 5 liters with easy cleaning facility.
Material of construction:Body should be compact, durable,
leak proof and made of stainless steel /heavy duty plastic.
Particle size:
It should consist aerosols with particle size of less than 5
microns
The blower head should be rust proof and deliver aerosols
10 Fumigator 01 4000.00
uniformly.
Unit:
It should be compatible with all disinfectant solutions usual
concentration.
It should be compatible with maximum Ph range (both acid
and alkali).
The equipment should be of good quality and conform to
national/ international standards.
Power supply:
The machine should operate on 220 +- 10 volts, 50 Hz,
single phase, A.C
Provided with Cable should be at least 5 meters in length,
ISI marked.
The discharge rate should not be less than 1Liter/25
minutes.
The tank capacity, discharge rate and timer on the machine
should be so that the disinfectant should be able to disinfect
4000-5000 cubic feet in one cycle of 2 hours (max).peration.

Test sample Area:Approx 3m×3m×8cm.


Temp Range:25-75°C,temp unifomiyy±2°C.
UV Lamp/tube:As Per Standards IEC 61215/61646:2005,
IEC 613455
UV radiation non uniformity:±15% over the test plane.
UV radiometer:Should measure UV-A, UV-B (280nm to
400nm)
UV integrator:Should indicate measured UV irradiance on
the test plane for UV-A, UV-B in W/m2.
Module temperature measurement:
At least four module temperature sensors (RTD) for
11 UV chamber monitoring module rear side. 01 12000.00
The module temperature sensors shall be calibrated.
Electricity Supply:1-phase 230V±10% or 3-phase
440V±10%, Frequency: 50Hz (Automatically Resume the test
when there is power-cut )
Safety Protection:
1.Reverse phase sequence protection for three phase
2. Shock proof body
3. Emergency stop
4. Door Interlock
5. Temperature Protection
6. UV protected glass window.
Capacity:12 liters total volume.
Material of construction:Transparent, unbreakable
polycarbonate jar.
Unit:
Anaerobic Jar should provided with pressure -cum -vacuum gauge
12 01 10000.00
jar attached to the lid
Jar should be ideal for all strict anaerobic test conditions.
Lid should consist of O- ring gasket.
It should provided with petri dish (100mmdiatemer)
holder/SS rack.
TOTAL 567500.00
BAKERY & CONFECTIONARY LAB

Approx.
Sl. Name of the Quantit
Specification amount
No Equipment y
(Rs.)
Mixes for Bread, cake, biscuits and cookies ,
5litrs large SS bowl, 6speed setting pulse speed provides quick
Dough
1 start/stop, 3 types of beater mixing, power:1000w, includes: 1No 18,000.00
mixer(Stand)
stand mixer, dough hook, beater, egg whisk and mixture bowl
with lid(5L), Dimension 42×35.5×28.2 cm, 2.5kg.
Bread slicer under goes prior testing to ensure that they are
2 Bread slicer shock proof, 220-240v, Dimension: 650×740×780mm, 60-70 1No 35,000.00
kg.
5loaf bread form (17.72” ×13.39”), silicon nonstick baking
3 Bread mold liners mat bread mold, subway bread mold, and multiple 1No 4,000.00
purpose. washable
Rectangle
cake mold/ 3Pcs set 3 different sizes, high class aluminium highynic, easy
4 1No 600.00
bread to use and easy to clean.
mold/tin pan
Electronic Digital display, Scale: up to 3kg; Weigh in 0.01g increment
5 1No 6000.00
scale
Mixer jugs Capacity: 2 ltr, 1 ltr and 0.5 ltr. Heat-resistant polypropylene
6 1No 600.00

7 Dough sheeter Power: 1HP; W: 2ft, L:10ft; Phase: III (folding type) 1 No 35000.00

8 Oil spray unit Nozzle atomizer: 10micron; Capacity: 5ltr 1 No 1500.00

9 Roaster Capacity: 5kg/batch; Power: 220v; Temp.: 0-300oC 1 No 20,000.00

Baking All product mold, trolleys, muffin trays, cookies trays, cutters,
utensils and rollers, cake stand, pizza and doughnut cutter, icing bag, pie 1 No
10 15000.00
accessories cutter, tongs, nozzles, measuring cups, spoons, oven gloves, each
injection mold, cake cups (tart cups), scrappers, palate knifes,
cake decorator rounder

Proofer with Temp.: 30-500C; RH:90%; Power:3Kw; Motor: 0.25HP; Size


11 1 No 40000.00
controller (LBH): 70x50x180; Digital display; SS tray
Basics
Ideal for new bakers, includes a small- medium- and large
12 silicone 1 400.00
spatula, heat resistant silicon, attached plastic handle
spatula set
Aluminium
Feature: including 20 design die-plates, 1 press machine and 4
biscuit cookie
13 nozzles design, material: aluminium alloy + ABS, 1 3500.00
maker pump
size:21×15×5cm,
press machine
Electric single Version: electric, capacity: 4 trays, tray size: 12×12 inch,
14 1No 1,00,000.00
baking oven 380v, power: 12kw, dimension: 1250×900×920mm

Total 279600.00

FOOD PROCESSING AND PRESERVATION LAB


(FOOD BEVERAGES)
Approx.
Sl. Name of the
Specification Quantity amount
No Equipment
(Rs.)
The vegetable washing machines and fruit washing machines
can wash and clean multiple kinds of fruits and vegetables.
Fruit and The fruits are subjected to strong water agitation for removal
1 Vegetable of dirt. The washed fruits are then conveyed to the next state 01 100000
Washer by a pickup conveyor. Available in the following models.

50-100 kg/hr capacity. 1-2 hp motor.

Suitable for lifting the fruits / vegetables to be fed to the


2 Elevators 01 100000
crusher or extraction machines
Suitable for washing and / or peeling of root vegetables like
Root carrot, potato, radish etc. The machine is equipped with 7 to 9
Vegetable rotating soft/hard brushes which thoroughly clean and peel
3 01
Peeler / the vegetables under a jet spray. Capacity 100 kg/hr,
Washer furnished with 1HP motor.

These equipment are used for destoning, skin, removal,


pulping and finishing of pulps from produce like mangoes,
Fruit and litchi, pineapple, tomato, carrot etc.
Vegetable The equipment incorporate scraper rotors, spiral scraper and
4 01 80000
Pulper (Twin brushes rotating at high speed which separate the stone, skin
Stage) and pulp. The secondary stage refines the pulp received from
the primary stage. Made of MS & SS. Capacity 100kg/hr.
4HP
5 Helicoidally Suitable for extraction of juices from fruits like pineapple, 02 170000
Juice orange, apple, ginger, awla etc. Unique spiral design of the
Extractor machine ensures high yield juice recovery without making it
bitter. Continuous feeding/extraction of product ensures
minimal labour.
Capacity: 50kg to 100kg/hr. capacity. Made of MS.
This is a continuous juice extractor especially for fruits like
apple/grape/pear/pineapple/carrot etc. The speciality of this
Belt Press
6 equipment is high yield percentage of extracted juice. The 01 70000
equipment is robust, multi-purpose and easy to maintain.
Capacity 50- 100 kg/hr. 1HP motor. Made of MS.
Automatic plate type pasteurizer are designed for heating,
Plate Type
7 pasteurization, holding and cooling of liquids like milk, juice 01 100000
Pasteurizer
and other beverages to prolong their shelf life.
Suitable for cooking of pulp or juices or making sugar syrup /
Cooking brine solution. Made from SS 304, the kettle is 2/3rd jacketed
8 Kettle (Tilting for uniform distribution of the heat. The tilting of kettle 01 100000
Type) facilitates easy pouring of the preparation. Capacity: 10gal
(45 litres).
This cooking equipment is suitable for cooking and
concentrating products under vacuum to make jam, ketchup,
tomato puree etc. The vessel is interconnected with
. Vacuum
condenser, suitable vacuum pump / motor. A geared motor
Evaporated 01 35000
9 ensures slow speed scraping inside the vessel while cooking.
Kettle
Vaccum Cooking is done at 55o c temperature which
preserves the natural colour, aroma and taste of the product.
100 kg. Capacity.
The Kettle is available with fixed scraper attachment. The
Cooking
tuflon scraper scrapes the inner surface of kettle and is driven
Kettle (Fixed
by attached geared motor or gearbox-motor attachment. The
10 Type) 01 25000
scraper attachment ensures that there is no blackening or
with scraper
charring of product while cooking or heating.
attachment
50 litter capacity.
Multi-effect vacuum evaporators find wide application in
concentration of fruit / vegetable juices to produce juice
concentrates / tomato puree, paste etc.
The concentration is done at low temperatures to preserve
natural colour / aroma / nutrition content. It is equipped with
aroma recovery and on-line sugar concentration detection
system. Thus enhancing the consistency and quality of the
Multi-Effect
final products.
11 Vacuum 01 300000
Equipment type and Configuration:
Concentrator
Double, Triple and multi effect
Configuration: Falling film, Rising and forced circulations.
Attachments: Aroma Recovery / on-line sugar concentration
detector / CIP
Range: Fruit juice concentrates, tomato puree / paste, milk
Concentration: 32% - 71%
Evaporation capacity: 50-100 lit. /hr.
Suitable for dicing and cubing of vegetables likes papaya,
carrots, potato, pineapple etc. Unique design produces cubes
12 Dicer / Cuber in sizes of 5x5 mm or 20x20mm with interchangeable dies. 01 50000
We also provide Vegetable Slicer dicer and Vegetable Slicer
chopper.
Capacity : 50-100 kg/hr. Power load : 2 Hp
Suitable to slice and chop various vegetables like carrots,
potatoes and ginger etc. The vegetable slicer chopper can
Multifunction
produce variable sized slices which are then conveyed to the
Vegetable
chopping section. The intermittent chopping blade action
13 Slicer / 01 60000
produce slices/chops/cuts/finger-cuts etc. The cuts sizes can
Chopper.
be varied by the variable infeed conveyor.
Capacity : 50-100 kg/hr
Power Load : 1 HP
This machine is a Semi-Automatic Piston Type Filling
Machine and is suitable to fill thick viscous liquids with
GP
granules or pieces like Sauce, Pickle, and Salasa Sauce.
Paste/Pickle
14 Elegant in design and model, the machine has a vertical 01 135000
Filling
structure which saves space.
Machine
- Made of stainless steel, GMP standard
- Filling valve is controlled by the electro - magnetic sensor,
Suitable to peel garlic cloves. Specially designed peeling
chamber / blades ensure peeling without damaging the
Garlic Peeler -
15 cloves. 01 30000
Batch Type
Peeling Time: 3 to 4 minutes of each batch.
Available in : 50 and 100 kg/hr
These vegetable slicer is suitable for slicing or chopping
leafy vegetables, beans, tomatoes, chilli etc. Unique design
. Multi- incorporating infeed food grade conveyor controlled by a
Purpose variable speed drive controller and an adjustable gripping
16 01 85000
Vegetable conveyor which feeds the product to the clicking head. The
Slicer variable infeed controlled conveyor ensures variation in cut /
slice thickness of sizes.
Capacity 100kg/hr. motor 1 HP.
Automatic Suitable to fill and seam products like coffee, juice or
Can Filling carbonated beverages in cans. The machine is fully automatic
17 01 125000
and Seaming and incorporates integrated operations for can infeed - filling
Lines and seaming of the can. Capacity 100-200 cans per hour.
Dehydrator machine like food dehydrators and sterilization
machines are suitable for dehydration of fruits & vegetable to
homogenizing of liquids or pastes and for many other
16. Food purposes.
Dehydrator |
18 01 165000
Colloidal Mill These food dehydrator machine is
suitable for dehydration of fruits and
vegetables.
Tray types, 6, trays / batch capacities.
Electrically operated.
Suitable for filling viscous liquids like juice, ketchup and
syrup in glass bottles with narrow necks. Available in 2-6
19 Vaccum Filler head models in MS or SS finishes. 01 45000
Furnished with partial vacuum to fill PET bottles.
2 head,10-12 bottles/min
The double head filling machine can fill high and low viscous
liquids in two different containers at a time. They can be used
Double Head
20 in industries of pharmaceutics, foodstuffs, cosmetics, daily 01 65000
Filler
chemical for smooth and accurate filling into specified
containers.
Filling range Capacity Air usage
(ml) (fills/m) (Ft3/min)
20-1000 40-50 5.7
Designed to thoroughly clean and wash recycled narrow neck
Semi- glass bottles. The bottles are thoroughly cleaned from inside
Automatic by rotating brushes while these are simultaneously brushed
21 Bottle Washer and cleaned from outside by brushes. 01 100000
(Brushing) Production: 2000-2400 bottles/hr (depends upon bottle dirt)
No. of Washing Heads: 24
Power: 1.5 kw.
Suitable to wash fresh glass bottles.
Semi-
Production Capacity: 2000-2400 bottles/hr
22 Automatic 01 80000
No. of washing heads: 24
Bottle Rinser
Power: 0.75 kw.
Suitable for bottle capping with lug caps. Pneumatically
Lug Cap
operated and more efficient as well as faster.
Sealers
23 01 40000
(Table model) 10-12 bottles/min.
(Semi-automatic Pedestal model) 20-25 bottles/min
Ideal for Sealing crown corks on glass bottles. This is a
Crown simple hand operated machine, simple to operate fuse. Made
24 Corking of MS. 04 12000

Capacity: 8-10 Bottles/min


The PP cap sealer is ideally suitable for sealing bottles/bottle
capping with Pilfer Proof Caps. This method provides a
PP Cap Sealer
25 tamper proof sealing of the the opening of a containers. 02 50000
(Pedestal)
made of MS.
Motorised, 15 bottles/min.
Semi-
The automatic screw on cap sealer is used to provide tamper
Automatic
proof sealing for bottles and cans. These cap sealers can be
26 Screw on Cap 02 80000
used for continuous high speed and continuous sealing
Sealer
application.
Volumetric filler consists of cups fitted in a disc which get
evenly filled up by the product while in rotation. Machines
Volumetric incorporates volumetric cup filling mechanism for weighing.
27 Filler(Cup Suitable for weighing and filling free-flowing products like 01 5000
Filler) tea, whole spices, sugar etc. in cans/bottles/pouches.
Filling Range: 50gm.-1000gm.
Capacity: 5-15 fills/min.
Suitable for sealing pouches after filling. Pouches are feed
horizontally for sealing.
Speed: 15-20 pouches/min.
Semi- Sealing Speed
Automatic 100 Mt/min
28 Pouch Sealing (approx. 10 to 20 bags/min) 01 145000
Machine Sealing Width
(Horizontal) 6, 8, 10 and 12 mm (As per requirement)
Heater: 500 W x 2.Cooling: Forced Air Cooling
Power Consumption
3 phase 400V, 1.5 KW.
Suitable for filling sealing range of products from 50 gm-
1000 gm. It can be synchronised with different types of
filling systems.
Specification:
From Fill And Sealing type: 3 side, 4 side and Centre seal.
29 01 145000
Seal Machine Packing size: Length: 40 to 240 mm.
Width: 40 to 250 mm.
Packing Range:
Powder and Granules: 2 to 200 gm
Liquids: 2 to 20 ml, 20 to 50 ml & 50 to 100 ml.
This Continuous Spray Conveyor is suitable to reduce
the temperature of hot fill drink bottles to 30-36? C or to
increase the temperature of cold filling carbonic drinks
to 36-40? C. Its working process is divided into three
stages. First stage circulates hot water spray. Second
Bottle
stage does warm water pre-cooling. And in the third
Warming /
30 stage it does cold water-cooling. The time in each of the 01 225000
Cooling
three stages can be regulated as per requirement. The
Conveyor
complete structure is made of SS 304 while the
conveying belt is made of high temperature resistant
polypropylene (CPP)

FAB series Monobloc bottling machine is designed for hot


filling of juices / water. The advanced micro-negative filling
ensures accurate brim filling. It incorporates special designed
hot filling valves which can easily be cleaned (CIP). The
Automatic machine is controlled through touch screen PLC which
Monobloc controls the entire operation such as "No-Bottle-No-Cap".
Rinser filling / Also the inbuilt temperature sensing ensures that the
31 beverage is not filled below the set Filling temperature. 01 145000
Filler / Capper
(for Hot Fill Automatic flow control valves ensure that the excess
Juice / Water) beverage flows back to overflow holding tank.
Capacity (b/hr) 100
Rinsing heads 12
Filling heads 12
Capping heads 4
Name of this machine is volumetric liquid filling machine,
also known as hand operated liquid filler. This machine is
unique among small scale production units, because it is the
most economical and of course it is easy in operation. High
Hand fill abilities and various settable fill volumes as per
Operated requirement makes this the perfect filling machine. Any free
Liquid Filling flowing material or even partially free flowing material
Machine/ which is to be filled by volume can correctly filled by this
32 01 90000
Table Top machine.
Liquid Filling Specifications output: 20 to 40 bottles min. depending upon
Machine: the filling qty., bottle neck dia, and powder bulk density) fill
capacity: 5 gms. To 2kg. (With different set of auger and
funnel power characteristics: 3 phase input specifications
container. dia: as suitable. height: as suitable. accuracy: + or -
(1%) note: high lights of machine: it is compact machine,
self-supported on s.s. legs, with height adjustment.
Appro
Sl. Name of the Quantit x.
Specification
No Equipment y amoun
t (Rs.)

Mineral Water The 24 bpm mineral water bottle filling machine have long
33 Bottle Filling shelf life. We make sure that all the 24 bpm mineral water 01 60000
Machine bottle filling machine is made of superior raw materials.
This milk pasteurizer
is used to sterilization for milk, juice, drink, soya-
bean milk, condensed milk and so on.

Specifications:

1) Pasteurizer machine for juice


2) Used for milk, juice, and drink
3) Compact structure, small in size
Stainless Steel 4) Easy to operate
Flash
34 Pasteurizer Technical parameter: 01 165000
Machine for
Juice Capacity 0.5-1T/H
Sterilization temperature 115-135°C
Steam pressure <0.4MPa
Heating time 4-6S
Discharge temperature <65°C
Motor power 2.2KW
Dimension 1200*920*1400
Weight 210KG
1, 2 lit capacity. Two direction rotation, six press cone. Motor
35 Citrus Juicer 06 1200
driven.
Capacity 30 litres/hr. soya milk base 3.5% protein, made of
Soya bean
36 304 SS grade, provide with deodorizer system, 1 HP single 01 300000
milk processor
phase 220 V,
37 Alcohol meter Alcohol range: 0-99% 01 2000
38 Water Purifier 5 lit/min. capacity. 02 18000
Pressure 02 of
39 5 lit, 10 lit. Capacity. 4000
cooker each.
Two types. 02 of
40 Refractometer: 4000
each.
Made of S.S 304 grade. 8.5ft × 4.5 ft. and height 4ft. with a
41 Working table 03 45000
top sheet width of 3mm.
8.5ft × 4.5 ft. and height 4ft. made of food grade heavy
42 Wooden table 04 32000
wood.
Total 3556200.00
For Liquids : Capacity : 5 ml to 1 litre, PLC controls,
Form Fill Impulse sealing. Ink/heat batch coder, photo electric
Sealing Machine sensor, Output - between 2000 to 2500 pouches/hr per 10000
1 01
(Solid & Liquid) head For Solids : 500g to 1 kg, speed : 20-35 pouches / 0
minute, Feeding Head : Pneumatic Piston Filling System

Volumetric 01
Speed-10-20 bottles / min; Capacity: 250 to 1 litre. Motor
Filler-thick
2 1 HP, with four heads 50000
viscous liquids

Retort size 900 L x 2000 B, Max retort temperature : 01


Retort
150oC, Establish area, 1600 W x 4000 L x 2800H, Use
3 Processing unit 60000
max pressure 5 kg/cm2

Capacity: 20-25 Kg/batch; Thermocouple, Teflon 01


Steam Jacketed
scrapper (with spare scrapper), stirrer, pressure gauge
4 kettle 30000
safety and wheel valve attachments

SS 304 grade working table with sink and tap, Size :8 01


SS Table
5 1/2‟ x 4 ½‟ ht with Top and bottom : 2 mm 10000

Helicoidal Juice 01
Capacity: 50 to 300 Kg/h; Motor 1 Hp, III Phase
6 Extractor 40000

Chamber capacity : 500 L x 400 B x 150 H, 2 sealing 01


Vaccum Packing
heads, Seal : 400 Lx 3 W mm, 240 V, Dimensions : 665
7 Machine 25000
Lx 590 B x 950 H mm, With all necessary attachments

Deep freezer Capacity: 250 ltr; Temp. range: upto-300C 01


8 23000
Microcontroller pH meter of range 0-14; Accuracy: pH 01
+/- 0.01 unit; mV +/- 0.1% of full scale; Power:230V;
Digital pH meter
Temp. compensation : 0-100°C, with accessories like
9 - Water proof 15000
Combination pH Electrode, Temperature Probe, pH
Electrode Stand, Buffer Solutions, Data Cable

Capacity : 28 L, convection heat source, 6 power levels, 01


900W output, 1400W / 1250W power consumption, 230V
Micro wave
/ 50Hz power source, 12H and 24H clock system options
10 oven 12000
Clock, Supplied with round rack and with all necessary
accessories

Pneumatic Lug 01
Sealing rate:50 bottles/h; Air consumption: 1-1.2cfm;
cap sealing
11 with compressor and air filter 3500
machine

Brookfield KU-2+Digital Viscometer 01


Continuous Sensing & Display in Krebs units, Gram
units, Centipoise
Viscometer
12 Led digital display : 7500

Krebs units (Increased Resolution is 0.1Ku Increments)


Grams (in 1 Gram Increments & Centipoise (CP)
Measurement Rage: 40 to 141 Ku

32 to 1099 Gram 27 to 5274 Cps.


Accuracy: +/- 1.0% of full scale range
Repeatability +/- 0.5%
Output to paralled printer for automatic test
documentation
Optional air purge allows interior of Ku-2 to be
pressurized with air or inert gas.
Optional paste spindle for use with high consistency
materials such as paste.
Operating Temp: 10 Deg.C to 60 Deg.C
Spindle Speed: 350 rpm
Power supply: 230V, 50Hz, Supply

Shoul be supplied with adapters that accomdates quart,


pint & Half pint container, main instruments, krebs – type
spindle, communication fort for spindle with necessary
software. Brook filed Ku-2 Standards Calibrated: At
25 Deg.C., Available with nist traceable calibration
certificate. Available in 5 different Ku.61 Ku, 73 Ku, 87
Ku, 99, 106 Ku
Fruits and Capacity: 50Kg/h; Motor: 0.5 HP; Power 220V, Size: 01
13 Vegetable Peeler 30cm Dia 45cm Ht. 22000

Semi automatic, S.S. filling nozzle, S.S. Syringes, Cam 01


Bottle filling operated Syringes, Output: 8 to 10 bottles per minute, 2
14 40000
(each 500ml.), 1 HP motor

15 Fruit Microniser Capacity: 10 Kg; Motor: 1 HP; Power: I / III Phase 01 17000
Thermometer Digital thermometer, Range: -50 to 250oC x1oC; Hg 01
16 1500
filled; Anti-roll cap, T shape
SS moving Made of food grade SS, Double rack; Size: 36 x24x36 01
17 2500
trolley
Electronic scale Scale: up to 4kg; Weigh in 0.01g increments; with digital 01
18 3500
display
19 Hanging scale Scale: up to 30kg x 100g; Heavy duty, an adjustable tare. 01 1800
Plunger press Made of food grade stainless steel, Capacity:50 kg/h; 01
20 3500
(Citrus) Motor: 0.5hp (single phase)
Pedal/Pneumatic Size: 32" L ; Sealing : up to 10 mm; Power: 220 V, Single 01
Operate phase, with thermostat control, temperature control,
21 3000
Impulse/Heat autocut off
Seal/Machine
Digital Hand held, Range: 20-500oC; Power: 9V 01
22 thermometer- 500
Infrared
23 Salometer Scale: 0-100 parts per thousand ; ATC: 10-500C 01 1000
24 Refrigerator 12 litres capacity; 220V; 50Hz 01 15000
Bio reactor Capacity 2 lit with DO, pH; O2 sensors; temp sensors; 01
25 2000
rpm in-situ
Colour sorter for Lab scale colour sorter machine using the latest CCD 01
26 fruits & technology 5000
vegetables
Centrifuge Lab scale model; capacity up to 1 L/batch 01
27 2500
separator
28 Micro filter 0.05μm-0.1 μm with SS cover plate 01 2000
Single Drum Nominal size of stainless steel drum is 300 mm dia X 01
Dryer 200 mm wide (approx.).
The drum is hard chrome plated 4 nos. stainless steel
15000
29 small rollers (i.e. applicator Rolls) for the uniform drying.
0
Doctor’s knife to release the dried films.
The drum is operated by 1 H.P motor and driven by
reduction gear system.
Vacuum tray Capacity: 12 trays Temperature range: 40-110oC; 01
dryer Provided with digital temperature and pressure indicator. 14000
30
All contact parts are made out of SS304 / SS316 / 0
SS316L quality material
Contact plate Comprised with evaporating plates, hydrostatic 01
freezer transmission system, thermal insulation housing,
minimum 12 Plates, Plate Temperature < -35°C .unit will 25000
31
have separate refrigeration system, Temperature sensors 0
with digital display : 5 Thermocouples with temperature
accuracy of 0.1°C.
32 Ultra filter 0.05nm-0.1nm with SS cover 01 15000
Heat pump dryer Lab scale model, Hatch: Front loading / Energy Rating: 01
for specialty A,
33 crops need low 50000
temperature for
drying
Rising film Lab scale model; Single effect, feed pump capacity 0-100 01
evaporator kg/h, evaporation rate about 5-10 l/h; feed tank capacity
34 about 30- 50 Liter. System includes feed pumps, vapor 50000
condenser, major piping, and steel structure, control panel
etc.
Tray dryer Input voltage 230V, 30Amp Per 1hour current unit 6KW 01
Length, Width, Height ID 32.5” 32.5” 16.5” OD54” 54” 15700
35
23” Temperature control UP to 2000 C SS Tray 12 0
Heating coil 3nos
HTST laboratory Throughput:30 l/h max.; holding time 15sec at 20 l/h; 01
pasteurizer for temp up to 90oC for liquid
36 70000
milk and fruit
juices
Drum dryer Lab scale model; Steam consumption about 1.5kg dry 01
saturated steam @ 7 bar per kg of evaporation. Instrument
12000
37 should be provided with temperature, pressure indicator,
0
control panel and safety valve. Should be provided with
speed controller and hood provision should be available.
Multi-Purpose Capacity: 20 liters with temperature sensors for 01
Processing temperature 100± 0.1°C. Provided with steam or cooling
Vessel (oil/water water jacket. Cleaning is possible manually and
38 20000
emulsions; automatically in both way.
powder
incorporation)
pH Test 0 to 14 pH, digital indicator and be provided with all 01
39 5500
standard buffer solution
40 Retort sterilizing Laboratory model, main sterilizing unit size upto 50l, 01 50000
Unit with inbuilt boiler and compressor, provided with control
panel to note temperature, pressure indicator and safety
valve, SS stand to keep the product inside
Fluidized bed Temp 22-200oC; flow rate 0.42-2.4m3/min; maximum 01
dryer particle size, temperature indicator is required for inlet 20000
41
and outlet. Equipment should be attached with cyclone 0
separator
Freeze dryer Collector Capacity: 4kG, Collector Temperature: -50°c 01
Water Catching capacity: 2L/24hr, CFC free compressor
Inbuilt prefreezing with tray, Vaccum Pump with
displacement capacity > 100L/min,Vacuum : < 15Pa
Transparent Drying chamber with 8-ports for flask,
42
100ml, 250ml, 500ml, & 1000ml flasks -each 2No,
Ampoule adaptor-8Nos, Microprocessor based feather
touch controller, Large LCD graphical display, Trend
graph of vacuum, temp and Run time, Easy to move trolly
wheel
Colorimeter Able to measure samples of liquid, Solid and Powder, 01
Desirable Scale, L,a*,b* (SI units) Sensor geometry:•
45° circumferential illumination and 0° viewing,
Measuring area: • 3.75 inch (9.5 cm),Observer
Function:• 2° standard observer, Illuminant:• Illuminant
C,Light Source:• Continuous tungsten halogen lamp,
Display:• 10.4 inch (26.4 cm) color LCD with touch
screen Data and function input:• LCD touch screen
Hard copy data: • Built-in thermal printer Data
43 Connection:• USB and Ethernet, Data Storage: As
standard – thousands • As sample – thousands Statistics:
• Average, standard deviation, maximum, minimum,
range Color Scales: • CIE L*a*b*, Hunter Lab, CIE
LCh, Rd ab, CIE Yxy, CIE XYZ Color difference
scales: • ΔL*a*b*, ΔLab, ΔLCh, ΔRdab, ΔYxy, ΔXYZ,
Color difference indices: • ΔE*, ΔE, ΔC, ΔECMC, ΔC*,
Tolerances: User entered tolerances for color scales and
indices, CMC automatic tolerance, Pass/Fail displayed
based on tolerances.
45 Hot Plate (2KW) Standard 2 pcs 6000
Digital Weight Standard 2 pcs
Machine 0.5-200
46 2500
gm 0.001
accuracy
47 Citrus juicer Standard 2 pcs 3500
Baby fruit mill Standard 1pc
48 25000
(small)
49 Vegetable Slicer Standard 1 pc 20000
Bottle Cap Standard 2 pcs
50 tightening 7500
machine
Crown corking Standard 2 pcs
51 6000
machine
Lactometer Standard 1 pc
52 3500
(Digital)
53 Refrectometer 0-300Brix; 30-600Brix; 60-1000Brix; Digital hand held 1 pc 10000
each 0
54 Digital pH meter Standard 1 pc
SS Tray Standard 6 pcs
55
(Different Size)
SS pot Standard 6 pcs
56
(Different Size)
Platform Standard 1 pc
57
Balance (50kg)
Fruit knife Standard 1 set
58
(different Size)
Cutters Standard 1 set
59
(Different Size)
Digital Moisture Standard 1 pc
60
meter
61 Oil testing kit Standard 1 set
Hand sealer Standard 2 pcs
62
machine
63 Bottler opener Standard 2 pcs
64 Cap sealer Standard 2 pcs
Hot air oven Standard 1 pc
65
12x12x14
66 Micro Oven Standard 2 pcs
Electronic Standard 1 pc
67
centrifuge
68 Microscope Standard 1 pc
69 Thermometer Standard 2 pcs
Measuring Standard 1 each
Cylinder
70 50ml,100ml,250
ml,500ml,1000
ml
Slide & Cover Standard 2 dozen
72 Slip
(Microscope)
73 Water Bath Standard 1 pc
74 Test Tube Standard 2 dozen
75 Test Tube stand Standard 6 pcs
76 Test tube holder Standard 1 dozen
77 Spatula Standard 4 pcs
78 Petri Dish Standard 1 dozen
79 Bottle Washer Standard 2 pcs
80 Lemon Squeezer Standard 4 pcs
81 Bunsen burner Standard 6 pcs
Sieve (different Standard 2 pcs
82
mess size) each
Pressure Cooker Standard 1 each
83
3lit,5lit
Butyrometer ISI Standard 6 pcs
84
mark 270C
85 Lock Stopper Standard 2 pkts
Lock Stopper Standard 6 pcs
86
Key
Milk Pipette Standard 6 pcs
87
10.75 ml

Total

You might also like