You are on page 1of 2

5-wire TNS/TT System 4-wire TNC System

Energy External lightning No external External lightning No external PV system External lightning No external
Supply protection lightning protection protection lightning protection protection lightning protection
VPU I 3(R) LCF VPU I 3(R) LCF
280V/25KA 280V/12,5KA
VPU I 3+1 LCF VPU I 3+1 LCF up to 1000 V up to 1000 V
1351690000 1352090000
280 V/12,5KA 280 V/12,5 KA (w/o signalling) (w/o signalling) VPU PV I + II 3 VPU PV II 3 1000
1352020000 1352020000 1351670000 1352100000 1000 2530550000
Precounter (w/ signalling) (w/ signalling) On the 2530610000
installation with remote signalling: with remote signalling: VPU I 3+1(R) LCF 280V/25KA VPU I 3+1(R) LCF DC side with remote signalling: with remote signalling:
VPU I 3+1 R LCF VPU I 3+1 R LCF 1351780000 (o. Meldung) 280V/12,5KA VPU PV I + II 3 R 1000 VPU PV II 3 R 1000
280 V/12,5KA 1351770000 (w/ signalling) 1352020000 (o. Meldung) 2530620000
280 V/12,5KA 2530180000
1352030000 1352030000 1352030000 (w/ signalling)

VPU I 3+1 VPU I 3(R) VPU II 3(R) up to 1500 V


VPU II 3+1 up to 1500 V
280 V/12,5KA 280V/25KA 280V/40KA VPU PV I + II 3
280 40/65 VPU PV II 3 1500
1352230000 2062940000 1352700000 1500
252092000 2530640000
Main- (w/o signalling) (w/o signalling) 2530580000
2062910000 1352720000
distribution with remote signalling: with remote signalling:
(w/ signalling) (w/ signalling)
with remote signalling: with remote signalling:
VPU I 3+1 R VPU II 3+1 R VPU I 3+1(R) 280V/25KA VPU II 3+1(R) 280 40/65 VPU PV I + II 3 R 1500 VPU PV II 3 R 1500
280 V/12,5KA 280 40/65 2063080000 (w/o signalling) 2520920000 (w/o signalling) 2530590000 2530650000
1352240000 2520930000 2063070000 (w/ signalling) 2520930000 (w/ signalling)

VPU II 3(R) 280V/40KA 5-wire system 4-wire system


VPU II 3+1 VPU I 3
1352700000 (w/o signalling) VPU I 3+1
280 40/65 280V/12,5KA
1352720000 (w/ signalling) 280V/12,5KA
2520920000 1352200000
Sub- 1352230000
distibution with remote signalling: VPU II 3+1 280V 40/65KA with remote signalling: with remote signalling:
VPU II 3+1 R 2520920000 (w/o signalling) VPU I 3+1 R 280V/12,5KA VPU I 3 R 280V/12,5KA
280 40/65 2520930000 (w/ signalling) On the 1352240000 1352220000
2520930000
AC side
5-wire system 4-wire system
VPU II 3+1 VPU II 3
280 40/65 280 V/ 40 KA
2520920000 1352700000
Terminal
devices with remote signalling: with remote signalling:
VPU III SO LD+A with remote signalling:
VPU III R 230V/6KV AC VPU II 3+1 R 280 40/65 VPU II 3 R 280 V/40 KA
1351700000 2520930000 1352720000
1351650000
Selection guide
Lightning and surge protection
Let‘s connect.
Instrumentation External lightning No external External lightning No external
and control protection lightning protection protection lightning protection VARITECTOR
2 analogue 1 analogue
2 analoge Signalkreise
signal circuits signal circuits
VSPC 2CL 24 VDC
VSPC 2CL 24 VDC VSPC 1CL 24 VDC
8924470000
0…20mA 892447000 8924480000
0…10V
1 analoger Signalkreis
VSPC BASE 2CL VSPC BASE 2CL FG VSPC BASE 1CL FG
VSSC4 CL 24 VAC/DC 0.5 A
8924710000 8924270000 8924290000
1063730000

2 binary signals
2 binary signals 24 V VSPC MOV 2CH
VSPC 2SL 24 VDC 230V
24V 8924330000 8924610000
AC/DC
230V AC VSPC BASE 2SL 1 binary signal24 V
8924720000 VSSC4 SL 24 VAC/DC 0.5 A
VSPC BASE 1 binary signal
1063840000
2/4CH FG VSSC4 MOV 240VAC/DC
8924300000 1064020000

telephone protect
RS485/ Modbus RTU VSPC TELE UK0
VSPC RS485 2CH 2WIRE
Ethernet Ethernet Cat. 6 8924670000 8924660000
Data VDATA CAT6
Telephone 1348590000 RS485/PROFIBUS DP VSPC BASE
VSPC BASE 2CL
8924710000 VSSC6 RS485 DP 2CL FG
1065010000 8924270000

Weidmüller GmbH & Co. KG


Ohmstraße 9
32758 Detmold
www.weidmueller.com
Let‘s connect.
weidmueller.com/varitector