You are on page 1of 11

STRUCTURAL

STEEL DESIGN
CALCULATIONS
DESIGN OF PINNACLE
CRESCENT

ENG.SWETHA
TABLE OF CONTENTS

1. DESIGN CODES

2. MATERIAL SPECIFICATIONS

3. DESIGN ASSUMPTIONS

4. LOAD COMBINATIONS

5. CONNECTION DATA

6. OUTPUT FILE
1. DESIGN CODES :

The steel pinnacle structure described in these has been designed according
to the following codes.

 AISC-2005 American Institute of Steel Construction


 MBMA-2006 Metal Building Manufacturers Association
 ASCE 7 Minimum Design Loads for Buildings and other structures
 AWS American Welding Society

2. MATERIAL SPECIFICATIONS :

The following is the list of the material standards and specifications for which
the building components have been designed:

No. Structural Components Material Specifications Strength

1 Built-up Sections ASTM A572M Grade 345 OR EN 10025 S355 JR Fy = 345


N/mm2
2Hot RolledSections
Tubes ASTM A 500 Grade B OR JIS G 3445 STKM Fy = 317 N/mm2
I-sections ASTM A 572M Grade 345 OR EN 10025 S355 JR Fy = 345
N/mm2
Channels ASTM A 572M Grade 345 OR EN 10025 S355 JR Fy = 345
N/mm2
3 Cold formed secondary members ASTM A653M SS Grade 340 Class 1
Coating: Z 275 Fy = 340 N/mm2
4Sheeting Panels
Aluzinc coated steel Bare &Pre-painted
ASTM A792M Grade 340 Class 1 Coating: AZM 150 Fy = 340 N/mm2
Aluminum Mill finish & Prepainted
ASTM B 209 Grade AA 3105, Temper: H16
Fu =170 N/mm2 (min.)
Fy = 145 N/mm2
5 Mezzanine Decking Panels ASTM A653M SS Grade 340 Class 1: Coating Z180
Fy = 340 N/mm2
6Diagonal “X”Bracing
Cable :ASTM A475 – Extra High Strength Class A ( Ωt = 2.50 ) Pu = 90 kN
Rods :ASTM A36 ( Fu = 400 N/mm2 ) Fy = 250 N/mm2
HR Angles :L 75x75x6
L 100x100x8
ASTM – A36M ( Fu = 400 N/mm2 ) Fy = 250 N/mm2
OTHERANGLES:
ASTM – A572 Grade 345
( Fu = 450 N/mm2 )
Fy = 345 N/mm2
7 Anchor Bolts
ASTM F 1554 Grade 36 OR Din 933 Grade 4.6
Hot Dip Galvanized to A153, Class C or equivalent
Fy = 250 N/mm2
8 High Strength Bolts
Din 933 Grade 8.8 or equivalent.(Fully threaded)
Hot Dip Galvanized to BS 729 ( Fu = 800 N/mm2 )
Fy = 630 N/mm2
9 Sag Rods
ASTM A36 OR Din 933 Grade 4.6
Electro galvanized to B633
Fy = 250 N/mm2

Fy = Yield Strength. Fu = Ultimate Tensile Strength. Pu = Minimum Breaking


Load.

3.DESIGN ASSUMPTIONS :
• The main frame rafters and exterior columns are rigidly connected to each
other (using moment type connections).
• The exterior columns are Pinned connected to the foundations.
• The lateral stability of the building is provided through the frame action of
the main frames.
• The longitudinal stability of the building is provided through the braced
action in the cross braced bays of the building.
• The frames at the endwalls are rigid frame.
3.LOAD COMBINATIONS :
1) Dead Load + Collateral Load
2) Dead Load + Collateral Load + Live Load
3) Dead Load + Collateral load + 0.75Live Load + 0.75Wind Load
4) 0.60Dead Load + Wind Load
5) Dead Load + Collateral Load + 0.75Live Load + 0.525Seismic Load
6) 0.60Dead Load + 0.70Seismic Load
4. CONNECTIONS DATA:

STANDARD PRIMARY CON NECTION BOLT DESIGN


STANDARD SECONDARY C ONNECTION BOLT DESIG N
STANDARD CONNECTION BOLT TORQUE VALUES
DESIGN OUTPUT FILE

RIGID FRAME (TYP)

Staad output :