You are on page 1of 4

Before Scanning,please execute the MML command DSP BRDMFRINFO to query the RRU information

and save it in txt. Also pay attention that some RRU do not support on line scanning.
RRU3805 MRFU
SRRU3804/3806 WRFU RRU3808
V1/V2 V1/V2
High-resolution on-line
X X √ √ √
frequency scan FFT
Broadband on-line frequency
X X √ √ √
scan FFT
Broadband off-line frequency
√ √ √ √ √
scan FFT

Cell Performance Monitoring on RNC:


Input Cell ID

Select:
RTWP
Cell User Number

NodeB side RRU Board RTWP Monitoring


Select one of the two methods, it is better selecting method one if only monitor a short period.
1) Board RTWP monitor(recommend it when collection short period RTWP)
Requirement:2 hour or longer
Data collect method:
Workspace->Monitor->Board RTWP
Input corresponding Cabinet No.-Subrack No.-Slot No. of RRU/RFU:
R15/R16 Version FFT
NodeB webLMTMonitor Spectrum MeasureFFT Frequency Scan
There are three kinds of FFT scanning, Chose the scanning method according to your needs (some RRU
only support offline FFT), commonly do the FFT scanning in the spare time at least for 10 minutes:
High-resolution on-line frequency scan
Broadband on-line frequency scan
Broadband off-line frequency scan

High-resolution: RBW (kHz)=15:


Broad-online: RBW (kHz)=100

Broad-offline: RBW (kHz)=100


If the Off-line Frequency scan, then need to first block the RRU and deactive UCELL, using MML
command: BLK BRD on NodeB side and DEA UCELL on RNC side.
After the scan, UBL BRD on NodeB. Then ACT UCELL on RNC.