You are on page 1of 1

100 THK.

20MPa RC SLAB 600


600 REFER TO ARCH. DRGS
WITH SE62 MESH C
FOR REBATE DETAILS, FOR TIMBER FRAMING.
(35 TOP COVER)
REFER TO ARCHI. DETAILS FIXED TO SLAB TO
ON 50mm POLYSTYRENE ON DPM
ON 25mm SAND ON 150mm MIN. NZS 3604:2011 D12 TRIMMER.
D12 TRIMMER. COMPACTED HARDFILL U.N.O. DPC

150 MIN.
225MIN.

PAVING
150 MIN.
225MIN.

PAVING

d
OR

TO
100
OR

TO

GL
D12-600, LAP 600 INTO SLAB, GL
BEND 150 ALONG FOOTING

(D) MIN.
(D) MIN.

20 SERIES GRADE B
REINFORCED CONCRETE
MASONRY WALL, FULLY

d
d

FILLED WITH 20MPa GROUT

b b
(b) WIDE x (d) DEEP 20MPa STRIP
FOOTING WITH 2D12 & R6 @ 600
CRS. 75 BTM & SIDE COVER (TYP)
b d D b d D b d
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

1 STRIP FOOTING AT DOOR


1:10 (A1), 1:20 (A3)
2 STD STRIP FOOTING
1:10 (A1), 1:20 (A3)
3 SLAB THICKENING
1:10 (A1), 1:20 (A3)

D12 75mm SIDE & BTM COVER.


50 50 50

25mm DEEP SAWCUT.

b
50 R6 STIRRUP 50

D12, BEND 150mm @ END.


75mm SIDE & BEM COVER.
25
20
15

4 SAWCUT 5 FOOTING @ CORNER 6 FOOTING @ INTERSECTION


10

1:10 (A1), 1:20 (A3) 1:10 (A1), 1:20 (A3) 1:10 (A1), 1:20 (A3)
5
0
5
Original Size:

Design ACL Job Title. Drawing Title.


Survey
Drawn N.L
STANDARD STRIP FOOTING DETAILS
Checked RT & CC
Date JULY 2018
Scale AS SHOWN
A STANDARD STRIP FOOTING DETAILS 09/07/18 CAD Filename File No. Rev. Dwg. No.
CONSULTING CIVIL & STRUCTURAL ENGINEERS
No. Revision Details (Current Revision Date : #### ) Date c Copyright 2018 Airey Consultants Ltd ACENZ
Takapuna, Pukekohe, Howick, Queenstown,Christchurch, Orewa