BaseBox
MAINS SUPERVISION CONTROLLER
BASE UNIT FOR USE WITH DETACHABLE
COLOUR DISPLAY
Description
InteliMainsNTC BaseBox is designed for
multiple (up to 31) gen-sets operating in
parallel to mains. The controller connects
the group of gen-sets to the mains. It
can serve as a bus-tie synchronizing
controller between two groups of
gen-sets or as a feeder controller.
Benefits
AirGate Easy solution even for complex
Modern communications made simple. ComAp’s powerful AirGate technology is provided in
a range of our controllers and makes remote internet connection to the ComAp controller easy. systems with groups of gen-sets
Just register the AirGate enabled controller on our website and from then on let ComAp’s unique
system locate and maintain contact with the controller, no need to worry about VPN’s, Static IP
– less wiring and components
addresses or corporate firewalls, simple! ”AirGate – Simply connected.” Can be used as bus-tie synchronizer
or feeder controller
Complete solution for Import/
ComAp products meet the Export control in multiple
ComAp is a member of highest standards, with every
AMPS (The Association of stage of production undertaken parallel to Mains operation
Manufacturers of Power in accordance with the ISO The product has the Graphical site schematic for easy site
generating Systems). certification obtained in 1998. UL Certification. 2)
overview – aggregates in one place
1) all important system parameters
InteliMainsNTC BaseBox and InteliMainsNT BaseBox can be connected with ComAp colour displays InteliVision 5,
InteliVision 8 or InteliVision 17Touch. Many types of communication –
2)
UL Certification is available for InteliMainsNT BaseBox model. easy supervision and servicing
Features Integrated fixed and
Integrated PLC programmable functions
configurable protections
(same size as InteliSysNTC BaseBox)
3 phase integrated mains protections
Multiple parallel to Mains operation – System
(U + f), voltage unbalance
Baseload, Import/Export, External load
Mains IDMT overcurrent + Shortcurrent protection,
control, Temperature based load control
current unbalance, Mains Import / Export
Peak Shaving (kW and kVA)
Vector shift protection
Mains measurement: U, I, Hz, kW, kVAr, kVA, PF
3 phase integrated bus protections (U+f)
Bus measurement: U, Hz
All binary inputs free configurable for various protection
Selectable measurement ranges for AC
types: Warning / Write history / Write history + Active call /
voltages and currents 120 / 277 V, 0–1 / 0–5 A
Alarm Only / Alarm + History indication / Mains protect /
= High voltage applications support
Mains protect with fault reset / Sensor fail
Inputs and outputs configurable
Phase rotation and phase sequence supervision
for various customer needs
Additional 160 programmable protections configurable for
Controller redundancy
any measured value to create customer-specific protections
RS232 / RS485 interface with Modbus
Application security
support; Analog / GSM / ISDN / CDMA
modem support; SMS messages
Event-based history (up to 1000 records)
ANSI CODES
with customer-selectable list of stored
values; RTC; statistic values ANSI ANSI
Protection Protection
Interface to remote colour display unit code code
InteliVision 5 or InteliVision 8 25 Synchronism check 50 Overcurrent
DIN-Rail mount 27 Undervoltage 51 Overcurrent, IDMT
Bipolar binary outputs – possibility to
32 Overload 55 Power factor*
use BO as High or Low side switch
Secondary isolated RS485 interface 1) 32P Load shedding 59 Overvoltage
Ethernet connection (RJ45) 1) 37 Undercurrent* 78 Vectorshift
USB 2.0 slave interface 1) 46 Current unbalance 79 AC Reclosing
1)
Available only for InteliMainsNTC BaseBox model 47 Voltage asymmetry 81H Overfrequency
and phase sequence 81L Underfrequency
49T Temperature
Order codes monitoring*
81R ROCOF
Schematic diagram
LOAD 3xI L
3xU L
EDBACK
LCB FE
PEN
OSE/O
LCB CL
B
5
liVision
) + Inte
LOAD LCB x (FDR
3xU B NTC BaseBo
ains
InteliM
CAN
G1
AVR
OUT
GCB1
3xI G
3xU G
3xU B
MGCB i
IG-AVR
8
liVision
MG
x + Inte
BaseBo
MC
CB
MAINS R NTC
MASTE InteliSys
BF
OR
FEE
SELECT G2
EED
AVR
SYS
MC
DBA
LOA
3xU B
MAS
3xU M
OUT
BAC
BF
3xI M
STA
CK
DR
GCB2
TER
EED
3xI G
3xU G
K
AVRi
RT/S
ESE
MGCB
3xU B
B
SEL
i
ACK
TOP
IG-AVR
RVE
ECT
SPEED
OR
Vout
OR
GOVERN
A 5
liVision
liVision
8
x + Inte
) + Inte BaseBo
x (MGCB
NT
InteliGen
MC
Bo
MG
NTC Base
MC
SYS
teliMains
BC
In
CB
BF
LOS
STA
CLO
EED
SYS
MC
E/O
RT/S
LOA
SE/O
MAS
BAC
BF
STA
PEN
DR
TOP
TER
K
EED
PEN
RT/S
ESE
B
SEL
TOP
RVE
CK
ECT
2
OR
ation
r applic
it Breake
r Circu
er G enerato
= Mast
MGCB
A
er con troller
FDR = Feed
B
Features
AMF function based on mains failure,
outputs a signal to start the gen-set group
Many SPtM-equivalent mains parallel
modes (SysBaseload, Analog Extern
SysBaseload, Import / Export, Analog
Extern Import / Export, Temp By Power)
Peak shaving kW and kVA
Test mode (Test on load for the
complete gen-set group)
Two application layouts M INS
– AMCB only or
MCB+MGCB control (see schematics) LOAD 1
Ko1
Mains measurement: U, I, Hz, kW, kVAr, kVA, PF,
MCB
kWh exp., kWh imp., kVAhr exp., kVAhr imp.
Bus measurement: U, Hz
Sum gen-sets kW and kVAr LOAD 2
Ko2
Selectable partial or full MCB
and / or MGCB control
Load Shedding – 3 steps; selectable based
ision 5
on gen-sets ox power ) + InteliV
(MGCB or mains import LOAD 3
NTC BaseB Ko3
ns
InteHigh
liM ai voltage application support – AC voltage
MGCB
measurement range selectable 277 / 120V
Schematics G CB3
MAINS
GCB2
GCB1 LOAD 1
Ko1
MCB
G3
G2 LOAD 2
Ko2
G1
ision 5
) + InteliV LOAD 3
(MGCB
ns NTC BaseBox Ko3
InteliMai
MGCB
GCB3
GCB2
GCB1
MAINS
MCB G3
G2
G1
LOAD
ision 5
) + InteliV
(MGCB
ns NTC BaseBox
InteliMai
MGCB
G CB3
MAINS
GCB2
GCB1
MCB
G3
G2
LOAD
G1
ision 5
InteliMains NTC BaseBox ) + InteliV
(MGCB
ns NTC BaseBox
InteliMai
MGCB
BTB (Bus-tie Breaker)
application
Features
Bus Left measurement: U, I, Hz, kW, kVAr, kVA,
PF, kWh exp., kWh imp., kVAhr exp., kVAhr imp.
Bus Right measurement: U, Hz
Manual or automatic selection
of the gen-set group (side) to be
influenced during synchronizing
Selectable partial or full BTB control
Schematics
MAINS2
MAINS1
ision 5
) + InteliV
#2(MCB
ns NTC BaseBox
InteliMai
MCB2
MCB1
ion 5
InteliVis
#1(MCB) +
eBox
nsNT Bas
C
InteliMai LOAD 2
BTB1
GCB4
GCB3
LOAD 1
GCB2
GCB1
ion 8 G4
InteliVis
eBox (BTB) + G3
nsNT Bas
C
InteliMai
G2
G1
Monitoring tools
InteliMonitor with SCADA WebSupervisor & AirGate
InteliMonitor is a free SCADA SW for visualization of data WebSupervisor is cloud-based system designed for monitoring
in process applications. It can be customized to create and controlling ComAp controllers via the internet. This system
visualization of individual systems as well as producing offers a number of beneficial features that help optimize
automatically generated screens using the supplied templates. revenue for machinery fleets, as each piece of equipment can
be individually monitored for all important operation values.
Features
Manual or automatic connection
of the load to the bus bar
Load prioritization
Load shedding on each feeder
LCB (Local Circuit Breaker)
closing supervision
Possibility to monitor remotely
status of each feeder (connection
to other InteliMainsNTC BaseBox
and gen-set controllers on site)
Schematics
ion 5
InteliVis
(FDR) +
NTC
ns BaseBox
InteliMai
MAINS
LOAD 1
LCB1
MCB
ion 5
InteliVis
(FDR) +
NTC
ns BaseBox
InteliMai
LOAD 2
LCB2
ion 5
CB) + InteliVis
eBox (MG
nsNT Bas
C
InteliMai
MGCB
ion 5
InteliVis
ox (FDR) +
NTC BaseB
InteliMains
LOAD 3
LCB3
GCB3
GCB2
GCB1
Communication modules
G3
G2
G1
Voltage measurement 3ph / 3ph 277V 3ph / 3ph 120V / 277V 3ph / 3ph 120V / 277V
Communication interfaces CAN1, CAN2, RS232, RS485, CAN1, CAN2, RS232, RS485 CAN1, CAN2, RS232, RS485 (terminal only),
Modbus, Ethernet 1) (terminal only), Modbus, Ethernet 1) RS485 (multipurpose), USB, Ethernet,
Modbus, Modbus TCP, AirGate, Web server
User MODBUS - l l
KEY
1)
l included with communication modules
2)
- excluded depends on number of values in history record
Customer feedback
“ComAp’s InteliMains controller is essential for our bespoke and often complex power generation
solutions. The InteliMains functionality, when used in partnership with the internal ‘virtual PLC’,
makes a robust platform adaptable to virtually all applications. Add to that the Dual-Redundant
capability of InteliMains and a super-resilient system can be created. The enhanced communication
options are also a huge benefit enabling remote monitoring, control and interfacing via
third-party monitoring systems: The overall flexibility of ComAp’s modular concept enables Applied
Power Engineering to create specialised configurations to exactly meet our customers’ needs.”
Ian Hutchinson
Technical Operations Director
www.appliedpowerengineering.com
ComAp a.s.
Czech Republic
Phone: + 420 246 012 111
Fax: + 420 266 316 647
E-mail: info@comap.cz
Internet: www.comap.cz
Customer satisfaction is our mission. We continuously develop our people to be the best to succeed in our mission.
© ComAp. Features and specification are subject to change without prior notice. 2013-06/CPLEIMBB