Lattice Girder October 2005

Composite Floors
technical data

Composite floors using lattice girder normally consist of a temporarily propped precast plank,
which also acts as fully participating permanent formwork in conjunction with the in-situ
structural topping.

THE BENEFITS OF LATTICE In situations where self weight must be manufacturers but the table below will give
minimised, the lattice girder planks can be general guidance on performance characteristics.
GIRDER COMPOSITE FLOORS supplied with polystyrene void - formers
bonded to their upper surface. These are then Design
Fast to Erect incorporated within the insitu topping. Composite floors using lattice girder planks are
All planks which are manufactured to Alternatively, the planks can be manufactured designed in accordance with the relevant
the specific needs of the building can with lightweight aggregate concrete. This type sections of BS8110: (1997) The Structural Use
be erected at a rate of up to 100m2 of composite floor is equally suited to use in of Concrete.
per hour. almost every building type, masonry, steel or
concrete structures and particularly those with Diaphragm Action
Robust Construction progressive collapse considerations.
Composite lattice girder floors can be designed to
Designs to resist progressive collapse
provide diaphragm action to transmit horizontal
are simply and economically achieved. Section profiles forces to the primary supporting structure.
May vary in details depending on the
High Quality Finish
manufacturer. Fire Resistance
Level soffits which may be decorated
direct and toppings that can be power Composite lattice girder floors are normally
Plank Depths designed with a minimum 1 hour fire resistance
floated allowing total floor zone to
be minimised. The typical thickness of the plank ranges from although periods of up to 4 hours are possible.
50mm - 100mm depending on the design
Services specification. Sound Resistance
Large or small holes, services in the Composite Lattice Girder floors are suitable for
topping, beams within the depth of
Plank Widths use at first floor level in domestic housing to
the slab - all easily achieved. The plank widths are usually either 1200mm or create a quiet home for the benefit of home
2400mm, but other widths are available. owners, their families and neighbours.
High Load Capacity
Strong mechanical key between Structural Performance
precast and in-situ concrete. Span/Load capacities may vary slightly between

Fire Resistance Maximum Spans (metres)


Cover to reinforcement and concrete Slab
Imposed Depth
depth may be varied to cope with 115mm 125mm 150mm 175mm 200mm 225mm 250mm
Load
required fire resistance.
1.5 kN/m2 3.0 3.0 4.0 5.0 5.5 6.0 6.5
Sound
Meets the highest standard for 3.0 kN/m2 3.0 3.0 4.0 4.5 5.5 6.0 6.5
resistance of sound transmission.
5.0 kN/m2 2.5 3.0 3.5 4.5 5.0 5.5 6.5

7.5 kN/m2 2.5 2.5 3.5 4.0 5.0 5.5 6.0

Including 1.0 kN/m2 allowance for finishes.

Precast Flooring Federation 60 Charles Street, Leicester LE1 1FB


Telephone: 0116 253 6161 Fax: 0116 251 4568
e-mail: info@precastfloors.info www.precastfloors.info

www.precastfloors.info
Lattice Girder Planks

normally 600mm

115 to 250
in-situ overall
concrete depth

Typical Details
Composite Floors in Masonry Construction

Temporary prop
Temporary prop

Bearing on masonry more than 100mm Bearing on masonry less than 100mm Bearing on 100mm wall

Composite Floors in Steel Frame Construction

Support on Support on Nominal bearing more than 75mm (otherwise use a temporary prop)
ledger angles top flange

Composite Floors in Precast or In-situ Construction

Support on
Loose reinforcement omitted for clarity beam formwork Beam within depth of slab