BSS Storage Calorifiers 24/6/2003 9:12 am Page 1

BOSS Storage Calorifiers


and Buffer Storage Vessels
BSS Storage Calorifiers 24/6/2003 9:12 am Page 2

BOSS Storage Calorifiers - MS 120/500L

Description
Indirect storage type vitreous enamelled steel calorifiers
complete with insulation casing.
Sizes 120 to 500 litre.
Sizes 120 to 300 have in-line connections.

Application
Energy efficient and reliable method of providing hot water
for commercial and industrial premises such as schools,
hotels, hospitals, factories, sports and recreation centres
and retail stores. They are also suitable for domestic
dwellings and flats.

Advantages
Indirectly heated storage tanks with permanently welded in
heat exchangers.
Supplied complete with thermostat and T & P valve.
Compatible with all LTHW heating systems.
Connection facility for immersion heater.
Quality enamelling to DIN 4753/Part 3 for hygienic
water supply.
Low tendency to calcination due to smooth enamelling.

Insulation
Minimum heat loss due to CFC free heat insulation.
Sizes 120 to 300 have 35mm hard foam insulation.
Sizes 400 and 500 have 50mm hard foam insulation.
Easy clean outer cover.

Type MS 120L to 300L Capillary Type MS 400L and 500L


thermostat
(optional)

Temp/
pressure
Hot water
relief valve Thermometer
supply
Hot water
supply

Mg anode Screw in
Insulation
thermostat
Thermostat Steel (optional)
Primary cylinder, Secondary
flow enamelled return
Mg anode
inside Primary
flow
Steel
Immersion cylinder,
heater enamelled
Primary inside
Insulation Inspection
return flange Primary
return

Cold water Cold water


supply supply

Note: Drain point made through cold water inlet (see Dia. A) Note: Drain point made through cold water inlet (See Dia.A)

1
BSS Storage Calorifiers 24/6/2003 9:12 am Page 3

BOSS Storage Calorifiers - MS 120/500L

Specification
Description BOSS BOSS BOSS BOSS BOSS BOSS BOSS BOSS
storage storage storage storage storage storage storage storage
calorifier calorifier calorifier calorifier calorifier calorifier calorifier calorifier
MS 120L MS 150L MS 180L MS 210L MS 250L MS 300L MS 400L MS 500L

BSS Code Vented systems 55720034 55718856 55718867 55720045 55720056 55718878 55718889 55718908
BSS Code Unvented systems 55720089 55720108 55720119 55720130 55720141 55720152 55720163 55720174
Capacity (litres) 120 150 180 210 250 300 400 500
Primary connections flow/return BSP(F) 1” 1” 1” 1” 1” 1” 1” 1”
Cold and hot water connections BSP(M) 1” 1” 1” 1” 1” 1” 1” 1”
Secondary HW return BSP(M) - - - - - - 3/4” 3/4”
Thermostat BSP(F) 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 3/4” 3/4”
Inspection hole DN - - - - - - 180 180
Continuous rating hot water supply kW-l/h (1)
13.9/262 17.3/325 17.3/325 25.8/485 29.4/552 40.2/756 46.2/869 59/1111
Heat up time to 60OC. Mins 44 45 54 41 44 38 45 44
Primary heating flow rate l/h 1200 1400 1500 2100 2400 3100 3400 4400
Primary drop across coil surface m bar 18 35 35 84 136 242 446 835
Heating surface m 2
0.5 0.6 0.6 0.9 1.0 1.4 1.6 2.0
Temperature/pressure relief valve 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 1” 1”
Weight (approx) kg 47 51 55 65 71 77 139 159
Dimension A 915 1015 1165 1315 1565 1815 1530 1730
Dimension B 600 700 850 1000 1250 1500 1150 1350
Dimension C 300 345 345 525 525 615 440 560
Dimension D - - - - - - 540 660
Diameter without insulation øE 480 480 480 480 480 480 650 650
Diameter with insulation 560 560 560 560 560 560 740 740

At 82OC flow temperature and generating hot water from 10OC to 60OC.
(1)

Maximum temperature 95OC. Maximum working pressure 10 bar.

1”
1”
ø560
3/4”

1”

11/4”
ø740 øE
1/2”

80
3/4”
1”
øE
B A B 1”
A
C
2”
100 D
C

70 1”
ø257

1” 105
1”
160
ca. 65 100

ca.110
ø340 1”

Type MS 120L to MS 300L Type MS 400L and 500L

Dia.A

Cold water Cold water supply


Expansion
connection Vessel
UNVENTED KIT Expansion
Unvented unit Relief Valve
supplied with
component kit
Calorifier

Pressure
Heater/

Reducing
Valve Tundish
Drain Cock
Mains Isolating Single
Valve Strainer Check Valve Drain Cock

Drain cock & Isolating valve not included in unvented kit

2
BSS Storage Calorifiers 24/6/2003 9:12 am Page 4

BOSS Storage Calorifiers - MS 800/2000L

Description
Indirect storage type, vitreous enamelled steel calorifiers
complete with insulation. Sizes: 800 to 2000 litres.

Application
Energy efficient and reliable method of providing hot water FLEXCON

for commercial and industrial premises such as schools,


C

hotels, hospitals, factories, sports and recreation centres


and retail stores.

Advantages
Indirectly heated storage tanks with permanently welded in
heat exchangers.
Supplied complete with thermometer and T & P valve.
Compatible with all LTHW heating systems.
Connection facility for immersion heater.
Quality enamelling to DIN 4753/Part 3 for hygienic water
supply and optimum corrosion protection in connection
with magnesium anode (800 and 1000 litre) and stray
current anode (1500 and 2000 litre).
Low tendency to calcination due to smooth enamelling.
Adjustable feet for accurate levelling.

Insulation
Minimum heat loss due to CFC free heat insulation.
80mm soft foam cover.

Hot water supply

Mg Anode

Insulation
Thermometer
Screw in
thermostat
(optional)

Screw in
thermostat Primary flow
(optional)

Secondary return

Steel cylinder,
Inspection flange
enamelled inside
and connection
for immersion
heater
Primary return

Cold water inlet

Adjustable feet
Note: Drain point 1”

3
BSS Storage Calorifiers 24/6/2003 9:12 am Page 5

BOSS Storage Calorifiers - MS 800/2000L

Specification
Description BOSS BOSS BOSS BOSS
storage storage storage storage
calorifier calorifier calorifier calorifier
MS 800L MS 1000L MS 1500L MS 2000L

BSS Code Vented systems 55718919 55718930 55718941 55718952


BSS Code Unvented systems 55720185 55720196 55720204 55720311
Capacity (litres) 800 1000 1500 2000
Primary connections flow/return BSP(F) 1. 1/4” 1. 1/4” 2” 2”
Cold and hot water connections BSP(M) 1. 1/4” 1. 1/4” 2” 2”
Circulation connection BSP(M) 3/4” 3/4” 3/4” 3/4”
Thermostat BSP(F) 3/4” 3/4” 3/4” 3/4”
Inspection hole DN 205 205 205 205
Continuous rating hot water supply kW-l/h(1) 93/1608 119/2067 150/2613 175/3042
Heat up time from 10 C. Mins O
41 39 45 52
Primary heating flow rate l/h 7400 8800 11800 13600
Primary drop across coil surface m bar 760 316 64 108
Heating surface m2 3.5 4.5 6.4 7.3
Temperature/pressure relief valve 1. 1/4” 1. 1/2” 1 1/2” 2”
Weight (approx) kg 250 336 475 600
Dimension A 2150 2180 2250 2295
Dimension B 220 250 285 305
Dimension C 900 1200 1120 1120
Dimension D 150 175 250 250
Diameter without insulation øE 750 850 1000 1100
Diameter with insulation 910 1010 1160 1260

(1)
For 82OC primary flow and 60OC storage temperature/hot water temperature.
Maximum temperature 95OC. Maximum working pressure 10 bar.

1.1/4”
1.1/4” D 2”

1/2” 100 D
300 100
1/2”
3/4”
300
1” 3/4”
200
±5 250
3/4”
A 2”
75 øE
1.1/4”
øE
1750 1750
A C
C
50
3/4” 3/4”
ø2 ø28
80 0
50 270 2”
400 ø245 5 250
1.1/4” 185 150 ø24
185 165
D
B
D 2”
B 1”
1” 1.1/4” 80 70

Type MS 800L and 1000L Type MS 1500L and 2000L

4
BSS Storage Calorifiers 24/6/2003 9:12 am Page 6

BOSS Buffer Storage Vessels - ES 200/2000L

Description
Economical, high performance vitreous enamelled buffer
vessels for hot and cold water storage.
Sizes: 200 to 2000 litres.

Application
Load storage vessels for use in all closed circuit water
supply systems. Demand peaks satisfied by storage volume.
Supplied in standard form for vented systems. It can be
supplied in unvented form. This requires a correctly sized
T&P Valve to be factory fitted and an unvented kit supplied.
Contact BSS for size of valve required.

Advantages
High quality enamelling to DIN 4753/Part 3 for hygienic hot
water supply and optimum corrosion protection in connection
with magnesium anode (200 to 1000 litre) and stray current
anode (1500 and 2000 litre).

Insulation
Minimum heat loss due to CFC free heat insulation.
80mm soft foam jacket.

Hot water supply

Heat exchanger Thermostat


connection connection

Mg anode

Return Thermometer
connection

Insulation Inspection flange


(not on 200L)

Heat exchanger Thermostat


connection connection

Cold water supply

Adjustable feet
Note: Drain point 1”

5
BSS Storage Calorifiers 1/7/2003 2:03 pm Page 7

BOSS Buffer Storage Vessels - ES 200/2000L

Specification
Description BOSS BOSS BOSS BOSS BOSS BOSS
storage storage storage storage storage storage
vessel vessel vessel vessel vessel vessel
ES 200L ES 500L ES 750L ES 1000L ES 1500L ES 2000L

BSS Code Vented Systems* 55719002 55719013 55719024 55719035 55719046 55719057
Capacity (litres) 200 500 750 1000 1500 2000
Max. operating temperature OC 95 95 95 95 95 95
Max operating pressure bar 10 10 10 10 10 10
Cold/hot water connections BSP(M) 1” 1. 1/4” 1. 1/4” 1. 1/4” 2” 2”
Heat exchanger connections BSP(M) 1” 1. 1/4” 1. 1/4” 1. 1/4” 2” 2”
Circulation connections BSP 3/4” 1” 1” 1” 1” 1”
Thermostat connections BSP(F) 3/4” 1/2” 1/2” 1/2” 1/2” 1/2”
Thermometer connections BSP(F) 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”
Inspection flange connections DN - 110 110 110 110 110
Weight (approx) kg 53 125 160 200 350 420
Dimension A 1060 1400 1900 2160 2250 2295
Dimension B 750 1000 1500 1750 1750 1750
Dimension C - 720 970 1100 1375 1420
Diameter without insulation øD 550 750 750 800 1000 1100
Diameter with insulation 710 910 910 960 1160 1260

*Unvented on application

1 1/4”
1 1/4”

160

100 1/2”
80
1”
11/4”
1 1/4”

200 100 øD
150
1/2” 3/4”
1”
1/2”
1” 1” B
A
B øD
A

3/4”

1 1/4” C
1” 1” 1/2”
200 3/4”
90 1” 80

70
1” 70
185
65 60 1”
1 1/4”
1”

Type ES 200L Type ES 500L and 750L

1 1/4” 1 1/4”
2”

160
200

80 1/2”
100 1/2”
1 1/4”
2”

øD
øD
1/2”
1” B 1/2”
1” B
A
A

1 1/4” C
1/2”
2”
C
1/2”
80
100
70
200
70 1 1/4” 1”
2” 1”

Type ES 1000L Type ES 1500L and 2000L

6
BSS Storage Calorifiers 24/6/2003 9:12 am Page 8

BOSS Buffer Storage Vessels - SS 300/1000L

Description
Economical, high performance stainless steel buffer vessels
for hot and cold water storage. Sizes: 300 to 1000 litres.

Application
Load storage vessels for use in all closed circuit water
supply systems. Ideally suitable where hygienic conditions
are required, especially on potable water applications.

Advantages
Load storage vessels for use in all closed circuit water
supply systems. Demand peaks satisfied by storage volume.
Supplied in standard form for vented systems, it can be
supplied in unvented form. This requires a correctly sized
T&P Valve to be factory fitted and an unvented kit supplied.
Contact BSS for size of valve required.

Insulation
Minimum heat loss due to CFC free heat insulation.
80mm soft foam jacket.

Hot water supply

Heat exchanger Thermostat


connection connection

Circulation Thermometer
connection

Insulation Inspection flange

Heat exchanger Thermostat


connection connection

Cold water supply

Adjustable feet
Note: Drain point 1”

7
BSS Storage Calorifiers 24/6/2003 9:44 am Page 9

BOSS Buffer Storage Vessels - SS 300/1000L

Specification
Description BOSS BOSS BOSS BOSS
storage storage storage storage
vessel vessel vessel vessel
SS 300L SS 500L SS 750L SS 1000L

BSS Code Vented systems 55719068 55719079 55719090 55719109


Capacity (litres) 300 500 750 1000
Max. operating temperature OC 95 95 95 95
Max operating pressure bar 10 10 10 10
Cold/hot water connections BSP(M) 1” 1. 1/4” 1. 1/4” 1. 1/4”
Heat exchanger connections BSP(M) 1” 1. 1/4” 1. 1/4” 1. 1/4”
Circulation connections BSP 1” 1” 1” 1”
Thermostat connections BSP(F) 1/2” 1/2” 1/2” 1/2”
Thermometer connections BSP(F) 1/2” 1/2” 1/2” 1/2'
Inspection flange connections DN 110 110 110 110
Weight (approx) kg 75 125 160 200
Dimension A 1560 1400 1900 2160
Dimension B 1250 1000 1500 1750
Dimension C 810 720 970 1100
Diameter without insulation øD 550 750 750 800
Diameter with insulation 710 910 910 960

1 1/4”
1” 1 1/4”
1 1/4”
160

80 1/2”

80 1/2”

1 1/4”
1”

øD
øD
1/2”
1/2” 1” B
1” B A
A

1 1/4” C
1/2”
1”
C
1/2”
80
80
70
70
60 1 1/4” 1”
60 1”

Type SS 300L Type SS 500L and 750L

1 1/4” 1 1/4”

160

80 1/2”

1 1/4”

øD

1/2”
1” B
A

1 1/4” C
1/2”

80

70

70 1 1/4” 1”

Type SS 1000L

8
BSS Storage Calorifiers 24/6/2003 9:44 am Page 10

BOSS Buffer Storage Vessels - SV 200/2000L

Description
Mild steel buffer storage vessel for non potable water storage.
Sizes: 200 to 2000 litres.

Application
Buffer storage vessels suitable for closed circuit heating and
chilled water systems.

Advantages
Reduced boiler/chiller usage and improved system
efficiency through the storage of large quantities of water.
Externally painted, uncoated internally.

Insulation
Optional extra - insulation kit available for heating
systems (we do not recommend the use of insulation
jackets for chilled water systems).
Minimum heat loss due to CFC free heat insulation.
80mm soft foam jacket.

System connection

System connection System connection

Thermometer
connection Thermostat
connections

System connection System connection

Drain Point:
200L to 1000L: 1”
1500L and 2000L: 11/4”

9
BSS Storage Calorifiers 24/6/2003 9:44 am Page 11

BOSS Buffer Storage Vessels - SV 200/2000L

Specification
Description BOSS BOSS BOSS BOSS BOSS BOSS
storage storage storage storage storage storage
vessel vessel vessel vessel vessel vessel
SV 200L SV 500L SV 750L SV 1000L SV 1500L SV 2000L

BSS Code 55719120 55719131 55719142 55719153 55719164 55719175


Capacity (litres) 200 500 750 1000 1500 2000
Max. operating temperature OC 95 95 95 95 95 95
Max operating pressure bar 3 3 3 3 3 3
Flow/return connections BSP(M) 1. 1/4” 1. 1/2” 1. 1/2” 1. 1/2” 2” 2”
Thermostat/thermometer connections BSP(F) 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”
Weight (approx) kg 58 106 130 170 230 270
Dimension A 1010 1570 1900 2160 2260 2285
Dimension B 700 1250 1500 1750 1750 1750
Dimension C 350 625 750 875 875 875
Dimension D 185 185 220 230 290 300
Diameter without insulation øE 550 650 750 800 1000 1100
Diameter with insulation 710 810 910 960 1160 1260

100
3/4”
1.1/2” 1.1/2”
100
3/4”

1.1/4” 1.1/4” øE
øE

A B 3/4” B
A 3/4”

1.1/4”
C
3/4”
C

100 1.1/4”
1.1/2” 1.1/2”

3/4” 100
D
D

Type SV 200L Type SV 500L to 1000L

100
3/4”
2” 2”

øE

A B 3/4”

2” 2”
3/4” 100

Type SV 1500L and 2000L

10
BSS Storage Calorifiers 24/6/2003 9:44 am Page 12

BOSS Standard Unvented Kits

Calorifier type: 150 200 300 400 500 800 1000 1500 2000
Storage volume (litres): 150 200 300 400 500 800 1000 1500 2000
Flow rate (litres/minute): 12 16 25 30 33 58 74 93 108
Maximum system water content
including heater and pipework: 250 430 750 800 1250 1700 1700 2400 4500
BOSS EXPANSION VESSEL
25/3 G
35/3 G
60/3 G
80/3 G
100/3 G
170/3 G G
240/3 G
450/3 G
EXPANSION RELIEF VALVE
1/2”. 6 bar G G
3/4”. 6 bar G G G G G
1”. 6 bar G G
TUNDISH AND BUSH
1/2” x 3/4” G G
3/4” x 1” G G G G G
1” x 3/4” bush G G G G G
1. 1/4” x 1. 1/2” G G
PRESSURE REDUCING VALVE
3/4” PRS. 3 bar G G
1” 315. 3 bar G G G G
1. 1/4” 315. 3 bar G
1. 1/2” 315 3. bar G G
Pressure gauge G G G G G G G G G
SINGLE CHECK VALVE
3/4” G G
1” G G G G
1. 1/4” G
1. 1/2” G G
LINE STRAINER
3/4” G G
1” G G G G
1. 1/4” G
1. 1/2” G G

BSS Code: 55719249 55719260 55719271 55719282 55719293 55719301 55719312 55719323 55719334

T & P VALVE
3/4”. 25kW G G G
1”. 70kW G G
1. 1/4”. 80kW
1. 1/2”. 173kW G G G
2”. 184kW G

**Please note that the T&P valve is only suitable for the stated kW ratings. If the unit is to be connected to a heat source greater than
the stated kW rating, please refer back to BSS.
The T&P valve is factory fitted when unvented kit is ordered with the BOSS vessel, and is not supplied as part of the unvented kit.
(Drain cock and isolating valve are not included in the unvented kit).
11
BSS Storage Calorifiers 24/6/2003 11:30 am Page 13

Correx Anodes and Immersion Heaters

Description Technical Data


Available as an optional extra, Correx impressed current
anodes have been specially developed for the cathodic For enamelled For stainless
tanks steel tanks
protection of enamelled and stainless steel hot water tanks.
Primary power supply voltage 230V,50Hz 230V,50Hz
These units comprise of a potentiostat (the electronic brain)
Secondary nominal voltage. Max. 9.5V Max. 11V
and a titanium anode.
Secondary rated current. 0.1A 0.15A
Rated power. 0.95V 1.7V
Kind of protection (VDE) Class 2 Class 2
Advantages
Current consumption <4VA <6VA
No consumption of anodes. Operating temperature 0 to 60 C O
0 to 60OC
No formation of anode deposits.
No maintenance.
BSS Code Correx Anodes
Physiologically harmless.
Automatic control of protection current. 55719504 Correx Anodes up to 300 litres.
Permanent control of the potential. 55719515 Correx Anodes 400 to 700 litres.
No over protection (no risk of hydrogen evolution). 55719526 Correx Anodes over 800 litres.
LED operation/non operation indicator.
Minimal consumption of current.

Installation
Full installation instructions are supplied with each
Correx anode.

Immersion Elements
BSS Code Description Voltage Thread Length Suitable for capacities of (litres)
55719186 3kW immersion element 1Ph/230V-50Hz 2” 350mm 120 to 500
55719197 3kW immersion element 3Ph/400V-50HZ 2” 280mm 120 to 500
55719205 4.5kW immersion element 3Ph/400V-50HZ 2” 280mm 120 to 500
55719216 6kW immersion element 3Ph/400V-50HZ 2” 450mm 120 to 500 without coil/400 to 500 with coil
55719227 9kW immersion element 3Ph/400V-50HZ 2” 450mm 400 to 500 without coil
55719238 12kW immersion element 3Ph/400V-50HZ 2” 450mm 400 to 500 without coil

Temp and pressure relief valves Temperature rating in kW


Size 3/4” 1” 1.1/4” 1.1/2” 2”
Hot water boilers, if not protected properly, can explode
kW 44 70 80 173 184
with dangerous consequences to both life and property.
kW (per BSEN 1490) 25 50 75 100 -
Such explosions can be as a result of either expansion due
to an excessive rise in temperature or an over
pressurisation of the system.
A temperature and pressure relief valve must be fitted to an Cold water supply
Expansion
unvented system. UNVENTED KIT
Vessel
Expansion
Unvented unit Relief Valve
supplied with
To convert kW to Btu/hr multiply by 3412. component kit
Calorifier

Pressure
Heater/

Reducing
Valve Tundish
The temperature probe will safely open the relief valve at 90 to 95 C.
O

Mains Isolating Single


Valve Strainer Check Valve Drain Cock
The kW rating shown in the table on the right has been calculated in
accordance with BS.6759 part 1 and ASME IV. Larger capacities can be Drain cock and isolating valve are not included in the unvented kit.
accommodated by multiple valve installations.

12
BSS Storage Calorifiers 1/7/2003 2:02 pm Page 14

Total Systems Solution

Our technical service centres have comprehensive equipment, and technical advice is offered on site by
resources and experience to provide the most professional qualified technical engineers and systems designers. BSS
service to meet customer requirements. A design service lead our industry in backup technical literature and are
for heating and hot water generation solutions is available constantly updating our customers with the latest advances
along with a flue installation service and boiler in the heating & ventilating market.
commissioning. Site surveys for all types of HVAC

Since our foundation in 1899, BSS has built up a wealth


of expertise in supplying heating equipment to British
Industry and become the UK’s leading supplier. This has
been achieved by working in partnership with leading brand
manufacturers.

Hot Water Heating. When used in conjunction with a boiler,


The BOSS range of Plate Heat Exchangers has been the plate heat exchanger is ideal for domestic Hot Water
developed in conjunction with the market leaders in Plate (DHW) generation in Hotels, Hospitals, Nursing Homes,
Heat Exchanger technology and design, to ensure the Restaurants, leisure Centres, Military Bases etc.
highest quality of components and manufacture, giving
you complete peace of mind.

Plate heat exchangers offer many advantages over


traditional methods of heat transfer,and are now commonly
used for many applications in numerous industries:

DHW
Outlets

T P Booster Set
T
Storage
Boiler P.H.E. Cold
Feed

T P

Drain

Drain
Drain

13
BSS Storage Calorifiers 24/6/2003 11:30 am Page 15

Index

Boss Storage Calorifiers - MS 120 - 500 litres page 1


Specification page 2
Boss Storage Calorifiers - MS 800 - 2000 litres page 3
Specification page 4
Boss Buffer Storage Vessels - ES 200 - 2000 litres page 5
Specification page 6
Boss Buffer Storage Vessels - SS 300 - 1000 litres page 7
Specification page 8
Boss Buffer Storage Vessels - SV 200 - 2000 litres page 9
Specification page 10
Boss Standard Unvented Kits page 11
Correx Anodes and Immersion Heaters page 12
Total Systems Solution page 13
Index page 14

Boss Booster Sets are a range of fully automatic cold


water pumping sets incorporating one, two or three pumps
as standard. They provide a cost effective solution for
many water boosting applications in the domestic,
commercial and industrial environment, including potable
water distribution or pressure boosting where the existing
water supply pressure is insufficient to meet the demand,
or where the water supply comes via a mains water break
tank and has to subsequently be boosted for onward
distribution within a system or building.

Bossmix Commercial Showers are low maintenance, easy


to use, thermostatically controlled showers. They should be
the first choice for all industrial and commercial shower
installations, delivering a high flow of water at a constantly
safe temperature.

14
BSS Storage Calorifiers 24/6/2003 11:30 am Page 16

Tubes, Fittings & Flanges Valves & Filtration


Steel, Copper, Stainless Steel, Plastic & Composite Tubes Building Services & Process Valves in all materials. Strainers
& Fittings. Grooved & Pressfit Systems.Pipe Supports, & Filters.
Jointing & Tooling Ancillaries.

COPPER SPECIALISTS - EAST LONDON, CHESSINGTON, READING, BIRMINGHAM PROCESS VALVE SPECIALISTS - ABERDEEN, BIRMINGHAM, BRENTFORD, BRISTOL,
GRIMSBY, MANCHESTER, NEWCASTLE, ROMFORD, SHEFFIELD, STOCKTON

HVAC Controls & Metering Commercial Heating & Ventilation


HVAC Valves & Actuators, Fire Protection Equipment, LTHW, HTHW, Oil Fired, Gas Fired & Electrical Heating
Gas Solenoid Valves, Switchgear, Gauges & Thermometers, Equipment. Heat Exchange Equipment. Hot Water
Metering Products, Flow Indicators, Commercial Showers. Generation. Air Conditioning & Ventilation.

SPECIALISTS - BELFAST, BIRMINGHAM (CENTRAL), BOURNEMOUTH, BRENTFORD, BRISTOL, SPECIALISTS - BELFAST, BIRMINGHAM, BIRMINGHAM (CENTRAL), BRISTOL, CARDIFF,
CARLISLE, DUNDEE, EDINBURGH, GLASGOW, KINGS CROSS, LEICESTER, SHEFFIELD, WIGAN DUNDEE, EDINBURGH, GLASGOW, LEICESTER, LINCOLN, LUTON, MANCHESTER, NEWCASTLE,
NOTTINGHAM, PETERBOROUGH, PLYMOUTH, ROMFORD, STOCKTON

Pumps & Pumping Equipment


Building Services, Domestic, Commercial, Industrial All BSS branches will supply our entire range of pipeline and heating equip-
& Process Pumps. ment. Within this network of strategically placed branches, we have specialist
SPECIALISTS - ABERDEEN, BELFAST, BIRMINGHAM (CENTRAL), BOREHAMWOOD, product teams and more in-depth stock ranges.
BOURNEMOUTH, BRENTFORD, BRISTOL, CARDIFF, COVENTRY, CROYDON, DERBY, DUNDEE,
EDINBURGH, GLASGOW, GRIMSBY, HULL, KINGS CROSS, LEEDS, LEWES, LINCOLN, LIVER- These specialist branches are identified in the relevant product boxes.
POOL, LUTON, MAIDSTONE, NEWCASTLE, NORTHAMPTON, NORWICH, NOTTINGHAM, ROM-
FORD, SHEFFIELD, SOUTHAMPTON, STOCKTON, STOKE-ON-TRENT, WIGAN

BSS BRANCH LOCATIONS THROUGHOUT THE UK & IRELAND


www.bssuk.co.uk
ABERDEEN Unit 5, South Middleton Base, CORK Unit 20, South Link Park, KINGS CROSS Unit 2, 1 Brewery Road, PETERBOROUGH Unit 2A,
Greenwell Road, East Tullos, Aberdeen AB12 3AX Ballycurren Road, Grange, Cork Islington, London N7 9QJ Centurion Business Centre,Sturrock Way,
Tel: 01224 292929 Fax: 01224 898252 Tel: 00353 21 321588 Fax: 00353 21 321595 Tel: 020 7619 7600 Fax: 020 7700 2482 Bretton, Peterborough PE3 8YB
E-mail: 1550.sales@bssgroup.com E-mail: 1960.sales@bssgroup.com E-mail: 1160.sales@bssgroup.com Tel: 01733 336000 Fax: 01733 265790
E-mail: 1470.sales@bssgroup.com
BELFAST COVENTRY Unit 17, Torrington Avenue, LEEDS Turnkey Park Estate, Whitehall Road,
36-38 Duncrue Road, Coventry, West Midlands CV4 9HN Leeds LS12 6AD PLYMOUTH St. Modwen Road,
Duncrue Industrial Estate, Tel: 024 7669 4744 Fax: 024 7647 0574 Tel: 0113 203 2203 Fax: 0113 279 8662 Parkway Industrial Estate,Marsh Mills,
Belfast BT3 9BP E-mail: 1490.sales@bssgroup.com E-mail: 1350.sales@bssgroup.com Plymouth PL6 8LH
Tel: 028 9078 4000 Fax: 028 9078 4010 Tel: 01752 675300 Fax: 01752 220063
E-mail: 1910.sales@bssgroup.com CROYDON 34 Factory Lane, Croydon CR0 3RL LEICESTER 66 Cobden Street, E-mail: 1260.sales@bssgroup.com
Tel: 020 8662 2300 Fax: 020 8681 6142 Leicester LE1 2LB
BERMONDSEY 193-197 Long Lane, Bermondsey, E-mail: 1120.sales@bssgroup.com Tel: 0116 242 7800 Fax: 0116 253 2456 PRESTON Unit 1 and 2, Brookfield Street,
London SE1 4PN E-mail: 1440.sales@bssgroup.com Preston PR1 1NR
Tel: 020 7940 2100 Fax: 020 7403 3102 DARTFORD Unit 11, Orbital One, Tel: 01772 557800 Fax: 01772 259285
E-mail: 1150.sales@bssgroup.com Green Street, Green Road, Dartford, LEWES Unit 5, South Downs Business Park, E-mail: 1310.sales@bssgroup.com
Kent DA1 1QG Brooks Road, Lewes, East Sussex BN7 2FB
BIRMINGHAM Crystal Drive, Tel: 01322 289039 Fax: 01322 289149 Tel: 01273 485000 Fax: 01273 480709 READING Unit A3, Worton Drive,
Sandwell Business Park, Smethwick, Warley, E-mail: 1570.sales@bssgroup.com E-mail: 1190.sales@bssgroup.com Worton Grange Industrial Estate, Reading,
West Midlands B66 1QG Berkshire RG2 0TG
Tel: 0121 552 6000 Fax: 0121 552 5363 DERBY Riverside Road, Pride Park, LINCOLN Crofton Drive, Tel: 0118 975 6240 Fax: 0118 975 7841
E-mail: 1220.sales@bssgroup.com Derby DE24 8HH Allenby Trading Estate, Lincoln LN3 4NR E-mail: 1180.sales@bssgroup.com
Tel: 01332 685600 Fax: 01332 685601 Tel: 01522 565700 Fax: 01522 512678
ROMFORD King George Close,
BIRMINGHAM (CENTRAL) Unit 49, E-mail: 1450.sales@bssgroup.com E-mail: 1480.sales@bssgroup.com
Eastern Avenue West, Romford RM7 7PS
Gravelly Industrial Park, Tyburn Road,
Tel: 01708 771800 Fax: 01708 723168
Erdington, Birmingham B24 8TG DUBLIN* White Heather Industrial Estate, LIVERPOOL 82/94 Great Howard Street,
E-mail: 1130.sales@bssgroup.com
Tel: 0121 322 0370 Fax: 0121 322 2296 301 South Circular Road, Dublin 8 Liverpool L3 7AX
E-mail: 1810.sales@bssgroup.com Tel: 00353 14 165100 Fax: 00353 14 165165 Tel: 0151 482 2500 Fax: 0151 207 2317 SHEFFIELD Unit 15, Oakham Drive,
E-mail: 1930.sales@bssgroup.com E-mail: 1330.sales@bssgroup.com Parkwood Industrial Estate, Sheffield S3 9QX
BOREHAMWOOD Chester Road, Tel: 0114 289 3900 Fax: 0114 276 7178
Borehamwood, Hertfordshire WD6 1LT DUNDEE Unit 1-3, Rutherford Road, LUTON 1 Trojan Court, Laporte Way, E-mail: 1460.sales@bssgroup.com
Tel: 020 8327 4100 Fax: 020 8327 4101 Dryburgh Industrial Estate, Dundee DD2 3XH Luton LU4 8RJ
E-mail: 1500.sales@bssgroup.com Tel: 01382 823700 Fax: 01382 826921 Tel: 01582 875600 Fax: 01582 452050 SOUTHAMPTON Unit A1, Parham Drive,
E-mail: 1580.sales@bssgroup.com E-mail: 1420.sales@bssgroup.com Boyatt Wood Trading Estate, Eastleigh,
BOURNEMOUTH Unit 1, Wessex Trade Centre, Hampshire SO50 4NU
Ringwood Road, Poole, Dorset BH12 3PF EAST LONDON Units 6/7, Thomas Road, MAIDSTONE Unit 5, Wood Close, Tel: 023 8068 3700 Fax: 023 8064 3928
Tel: 01202 711300 Fax: 01202 711301 Limehouse, London E14 7BN. Quarry Wood Industrial Estate, Aylesford, E-mail: 1140.sales@bssgroup.com
E-mail: 1400.sales@bssgroup.com Tel: 020 7531 3900 Fax: 020 7537 4849 Kent ME20 7UB
E-mail: 1920.sales@bssgroup.com Tel: 01622 713606 Fax: 01622 713616 STOCKTON North Tees Industrial Estate,
BRENTFORD Transport Avenue, E-mail: 1850.sales@bssgroup.com Stockton-on-Tees, Teeside TS18 2RL
Great West Road, Brentford, Middlesex TW8 9HF EDINBURGH Pentland Industrial Estate, Loanhead, Tel: 01642 665500 Fax: 01642 674652
Tel: 020 8232 2727 Fax: 020 8232 2730 Edinburgh EH20 9QH MANCHESTER 1 Columbus Way, E-mail: 1660.sales@bssgroup.com
E-mail: 1110.sales@bssgroup.com Tel: 0131 440 5900 Fax: 0131 440 3761 Off Broadway, Salford M50 1UU
E-mail: 1560.sales@bssgroup.com Tel: 0161 888 6464 Fax: 0161 888 6465 STOKE-ON-TRENT Etruria Way, Basford,
BRISTOL Albert Road, St Philips, E-mail: 1340.sales@bssgroup.com Stoke-on-Trent ST4 6JQ
Bristol BS2 0BS EXETER 6 Otter Court, Manaton Close, Tel: 01782 382382 Fax: 01782 621456
Tel: 0117 972 7900 Fax: 0117 972 7901 Matford Business Park, Exeter EX2 8PF NEWCASTLE Sanderson Street, E-mail: 1360.sales@bssgroup.com
E-mail: 1250.sales@bssgroup.com Tel: 01392 457500 Fax: 01392 425976 Newcastle-upon-Tyne NE4 7PJ
E-mail: 1240.sales@bssgroup.com Tel: 0191 256 5100 Fax: 0191 272 3115 SWANSEA Century Park, Valley Way,
CAMBRIDGE Unit 3, Rosemary Lane, E-mail: 1650.sales@bssgroup.com Swansea Enterprise Park, Swansea SA6 8QP
Cambridge CB1 3LQ GLASGOW Unit A, Vermont Street, Tel: 01792 762300 Fax: 01792 775922
Tel: 01223 404040 Fax: 01223 240420 Kinning Park, Glasgow G41 1LU NORTHAMPTON Riverside Way, E-mail: 1290.sales@bssgroup.com
E-mail: 1840.sales@bssgroup.com Tel: 0141 418 4444 Fax: 0141 429 2638 Bedford Road, Northampton NN1 5NX
E-mail: 1540.sales@bssgroup.com Tel: 01604 251400 Fax: 01604 620588 SWINDON Unit 4A, Euroway Industrial Estate,
CARDIFF Unit 6, Central Trading Estate, E-mail: 1410.sales@bssgroup.com Ramsden Road, Swindon SN5 8YW
Herbert Street, Cardiff CF10 4TP GLOUCESTER Eastbrook Road Trading Estate, Tel: 01793 601500 Fax: 01793 512144
Tel: 029 2043 2400 Fax: 029 2049 7815 Gloucester GL4 3DB NORWICH Unit 13, Alston Road, E-mail: 1210.sales@bssgroup.com
E-mail: 1280.sales@bssgroup.com Tel: 01452 872200 Fax: 01452 309899 Hellesdon Park Industrial Estate,
E-mail: 1230.sales@bssgroup.com Norwich, Norfolk NR6 5DS WIGAN Lockflight Buildings,
CARLISLE Port Road Business Park, Carlisle, Tel: 01603 253200 Fax: 01603 418839 Wheatlea Industrial Estate, Wheatlea Road,
Cumbria CA2 7AF GRIMSBY Europa Park, off Gilbey Road, E-mail: 1710.sales@bssgroup.com Wigan, Lancs WN3 6XP
Tel: 01228 517600 Fax: 01228 598090 Grimsby DN31 2FD Tel: 01942 405 540 Fax: 01942 405 541
E-mail: 1780.sales@bssgroup.com Tel: 01472 265100 Fax: 01472 241638 NOTTINGHAM Longwall Avenue, E-mail: 1330.sales@bssgroup.com
E-mail: 1680.sales@bssgroup.com Queens Drive Industrial Estate,
WIRRAL Rossmore Road East,
CHESSINGTON Oakcroft Road, Nottingham NG2 1NA
Ellesmere Port, Wirral CH65 3DD
Chessington, Surrey KT9 1RH HULL Copenhagen Road, Tel: 0115 943 5900 Fax: 0115 986 1099
Tel: 0151 348 5400 Fax: 0151 357 2001
Tel: 020 8974 3800 Fax: 020 8391 5241 Sutton Fields Industrial Estate, Hull, E-mail: 1430.sales@bssgroup.com
E-mail: 1320.sales@bssgroup.com
E-mail: 1950.sales@bssgroup.com East Yorkshire HU7 0YH
Tel: 01482 625800 Fax: 01482 838870 OXFORD Unit C Taurus, Horspath Industrial Estate, WOLVERHAMPTON Unit 17,
COLCHESTER 6 Smeaton Close, E-mail: 1610.sales@bssgroup.com Peterley Road, Cowley, Oxford OX4 2TZ Webner Industrial Estate, Ettingshall Road
Severalls Industrial Park, Colchester C04 9QY Tel: 01865 398870 Fax: 01865 777552 Wolverhampton WV2 2LD
Tel: 01206 754720 Fax: 01206 752649 E-mail: 1630.sales@bssgroup.com Tel: 01902 403925 Fax: 01902 403913
E-mail: 1200.sales@bssgroup.com E-mail: 1600.mgr@bssgroup.com
© Copyright THE BSS GROUP PLC All rights reserved
Registered Office: The BSS Group PLC, Fleet House, Lee Circle, Leicester LE1 3QQ, England.
Tel: 0116 262 3232 Fax: 0116 253 1343 E-mail: reception@bssgroup.com Web: www.bssuk.co.uk