PLAN VIEW
NOT TO SCALE
PROFILE VIEW
NOT TO SCALE
INLET INVERT/HIGH WATER PVC DRAIN WITH TRAP AND FOUNDATION, SUBGRADE AND
LEVEL ALARM - ELEV. CHECK VALVE, CONTRACTOR BACKFILL DESIGNED BY OTHERS PROJECT SPECIFIC ELEVATIONS ACCESSORIES AND ADDITIONAL OPTIONS
10 TO SEAL IN FIELD DESCRIPTION VALUE (ft)
1'-0" FINISH GRADE/RIM ELEV. SEWAGE APPLICATION REQUIRING FM (CLASS1/DIVISION
LAG PUMP ON - ELEV. WET WELL FLOOR ELEV. 1) EXPLOSION PROOF PUMPS
TOTAL MANHOLE DEPTH SEWAGE APPLICATION - DURA PLATE (PVC CORROSION
1'-0" INVERT (IN) DEPTH
16 PROTECTION LINER) BY A-LOK
LEAD PUMP ON - ELEV.
SYSTEM CHARACTERISTICS
ODOR CONTROL FOR SEWAGE APPLICATION, 1800
DESCRIPTION VALUE SERIES MEDIA CANISTER FILTER BY WAGER
1'-6" 5 8 gpm
PROFILE SECTION DESIGN FLOW
NOT TO SCALE STATIC HEAD ft ACCESS COVER LOADING CRITERIA (SPECIFY ONLY ONE)
PUMPS OFF - ELEV.
6" 13 TOTAL DYNAMIC HEAD ft
LOW WATER LEVEL ALARM - ELEV. PEDESTRIAN LOADING (aluminum, non-vehicular, uniform
FORCE MAIN LENGTH ft 300 lbs/sq.ft. live load)
1'-6" 12 MANUFACTURER HOMA __ INCIDENTAL H-20 LOADING (aluminum, off street,
(SELECT ONLY ONE) ABS __ sidewalk, and low speed, non-impact areas of parking lots,
WET WELL FLOOR - ELEV. 16,000 lbs./sq.ft. dual wheel live load, 0% impact)
GRUNDFOS __
MOTOR SIZE Hp H-20 DIRECT TRAFFIC LOADING (in street, 16,000
*CONTROL ELEVATIONS SHOWN ARE lbs./sq.ft. dual wheel live load, 30% impact)
FULL LOAD AMPS A
BASED ON 2" PUMP AND 75 GPM 6" PRESSURE FOUNDATION, SUBGRADE AND H-20-44 PARKING LOT LOADING (parking lots and alley
TRANSDUCER AVAILABLE POWER SUPPLY _ PHASE ___ V
DISCHARGE FLOW. CONTROL ELEVATIONS BACKFILL DESIGNED BY OTHERS ways where speed does not exceed 15 mph)
MUST BE CALCULATED FOR ALL SYSTEMS. OFFSET NUMBER OF PUMPS
DISCLAIMERS, INCLUDING BUT NOT LIMITED TO: Copyright Information 2014 Jensen PROJECT:
Precast All Rights Reserved. All
1.) Elevations provided by others. Changes greater than 0.1' require engineer approval. Field elevations have not been verified by Jensen Precast. Refer to Jensen Precast concrete production drawings for materials appearing as Jensen Precast
documents and the like are propriety 2" DISCHARGE LIFT STATION
concrete excavation. These mechanical drawings are not intended for setting of precast structures. work product and are protected under
U.S. copyright and other laws. Unless
MECHANICAL DETAIL ENGINEERED
2.) Pump station design characteristics such as, but not limited to; inflow rate, on-site power availability, etc., were provided by the engineer of record. in conjunction with business conducted
with Jensen Precast, any use of
3.) Purchasing agent must verify pump station complies with engineering plans, specifications, and site conditions prior to production. Jensen Precast work product without SYSTEMS
express, written consent is prohibited
and recipient is prohibited from 521 DUNN CIRCLE, SPARKS, NV 89431
4.) Site assembly required. Purchasing agent is responsible for assembly of entire pump station. Includes but is not limited to; off-loading & setting of concrete material, piping assembly, and electrical wiring. distributing any and all work product to DATE: DRAWN BY: SHEET NO:
JensenEngineeredSystems.com
non-approved third parties under
5.) Location of control panel must be disclosed to Jensen Precast. penalty of civil action. April 2014 NEC 2 of 2 (855) 468-5600