PENETRANT TESTING REPORT


Client NESMA Reference Code ASME V Article 6 Date Tested January 25-26, 2019
Project Test Procedure QCP/TCR/PT/1.0 Rev. 2 Report No. RP-19-PT-006-TCR
Location Al Hassa, KSA Acceptance Standard AS PER PROCEDURE Page 1 of 1
TEST METHOD CONSUMABLES SURFACE CONDITION
Solvent Removable Cleaner MAGANAFLUX SKC-S Welded Grinded
Water Washable Penetrant MAGNAFLUX SKL-SP2 Machined Others
Post-Emulsifying Developer MAGNAFLUX SKD-S2 Forged
Visible Emulsifier - Casting
Fluorescent Others - Rolled
INSPECTION PROCESS
Pre-Cleaning Wiping Emulsifier Application -
Penetrant Application Wiping Visible Light Intensity 100 fc
Penetrant Removal Wiping Black Light Intensity -
Developer Application Spraying Minimum Developing Time 10 mins.
Drying Process Normal Testing Temperature Ambient
Minimun Dwell Time 10 mins. Post-Cleaning Wiping
Item Specification KSAU Generator Main Tank “40,000”
TEST RESULTS
S.I No. Item Description Observation Result
1 Front Dish No Relevant Surface Indication ACCEPTED
2 Shell 1 No Relevant Surface Indication ACCEPTED
3 Shell 2 No Relevant Surface Indication ACCEPTED
4 Shell 3 No Relevant Surface Indication ACCEPTED
5 Shell 4 No Relevant Surface Indication ACCEPTED
6 Shell 5 No Relevant Surface Indication ACCEPTED
7 Shell 6 No Relevant Surface Indication ACCEPTED
8 Shell 7 No Relevant Surface Indication ACCEPTED
9 Shell 8 No Relevant Surface Indication ACCEPTED
10 Rear Dish No Relevant Surface Indication ACCEPTED
NOTE Only accessible weld joints were inspected with Penetrant Testing.
ATTACHMENTS

FIG.1 External welds of KSAU Generator Main Tank FIG.2 Internal welds of KSAU Generator Main Tank
Inspected by: Reviewed by:

RONEL CUSTODIO NAGESH SHINDE


TCR ARABIA NDT Level II TCR ARABIA NDT MANAGER ASNT LEVEL III
Date January 27, 2019 Date January 27, 2019