You are on page 1of 2

Fórmulas para la interpretación de la Capacidad Portante por

1
𝑞𝑢 = 𝑐. 𝑁𝑐 + 𝑞. 𝑁𝑞 + . 𝛾. 𝐵. 𝑁𝛾
2
𝐷𝑜𝑛𝑑𝑒:
𝑐 = 𝑐𝑜ℎ𝑒𝑠𝑖ó𝑛 𝑑𝑒𝑙 𝑠𝑢𝑒𝑙𝑜
𝛾 = 𝑝𝑒𝑠𝑜 𝑒𝑠𝑝𝑒𝑐í𝑓𝑖𝑐𝑜 𝑑𝑒𝑙 𝑠𝑢𝑒𝑙𝑜
𝑞 = 𝛾. 𝐷𝑓
𝛾 = 𝐺𝑠. 𝛾𝑎𝑔𝑢𝑎
𝑁𝑐 , 𝑁𝑞 , 𝑁𝛾 = 𝑓𝑎𝑐𝑡𝑜𝑟𝑒𝑠 𝑑𝑒 𝑐𝑎𝑝𝑎𝑐𝑖𝑑𝑎𝑑 𝑑𝑒 𝑐𝑎𝑟𝑔𝑎 𝑎𝑑𝑖𝑚𝑒𝑛𝑠𝑖𝑜𝑛𝑎𝑙𝑒𝑠 𝑞𝑢𝑒 𝑠𝑜𝑛 ú𝑛𝑖𝑐𝑎𝑚𝑒𝑛𝑡𝑒

𝑓𝑢𝑛𝑐𝑖𝑜𝑛𝑒𝑠 𝑑𝑒𝑙 á𝑛𝑔𝑢𝑙𝑜 𝑑𝑒 𝑓𝑟𝑖𝑐𝑐𝑖ó𝑛 𝑑𝑒𝑙 𝑠𝑢𝑒𝑙, 𝜙.


𝜋 𝜑
𝑁𝑞 = 𝑒 𝜋∗𝑡𝑎𝑛𝜑 ∗ 𝑡𝑎𝑛2 ( + )
4 2
𝑁𝑞 − 1
𝑁𝑐 =
tan 𝜑
𝑁𝛾 = 2(𝑁𝑞 + 1) tan 𝜙

Datos:
𝜑 = 20.88°
𝑐 = 0.87 𝑘𝑃𝑎
𝐵 = 𝑏𝑎𝑠𝑒 𝑑𝑒 𝑙𝑎 𝑐𝑎𝑙𝑖𝑐𝑎𝑡𝑎 = 1 𝑚
1.84 + 1.83 + 1.88
𝐺𝑠 = = 1.85
3
Cálculos de factores:
𝑁𝑞 = 6.99
𝑁𝑐 = 15.69
𝑁ϒ = 6.09
𝑘𝑁
ϒ = 1.85(9.81) = 18.1485
𝑚3
𝑞 = 18.1485 (3) = 54.4455 𝑘𝑃𝑎
RESULTADOS:
Carga Última:
1
𝑞𝑢 = 0.87(15.69) + 54.4455 (6.99) + (18.1485)(1)(6.09)
2
𝑞𝑢 = 449.4865 𝑘𝑃𝑎
Carga Neta:
𝑞𝑛𝑒𝑡𝑎(𝑢) = 𝑞𝑢 − 𝑞 = 395.041 𝑘𝑃𝑎
CARGA ADMISIBLE Y CARGA NETA ADMISIBLE:
FS = 3
𝑞𝑢 𝒌𝒈
𝑞𝑎𝑑𝑚 = = 149.829 𝑘𝑃𝑎 = 𝟏. 𝟓𝟎
𝐹𝑆 𝒄𝒎𝟐
𝑞𝑢 − 𝑞 841.313 𝒌𝒈
𝑞𝑛𝑒𝑡𝑎(𝑎𝑑𝑚) = = = 131.680 𝑘𝑃𝑎 = 𝟏. 𝟑𝟐
𝐹𝑆 3 𝒄𝒎𝟐

CONSTRUCCIONES 2