You are on page 1of 26

1.

High Precision Fiber Clever FC-6S


Evaluated
No Specification Requirement Comply Technical Specification Reference
(BD/NBD
1 Applicable
Page 1, Catalog FC-6S
Cladding meter F 125 µm BD Comply F 125 µm Fiber Cleaver
The bidder commit to
Fiber count Single fiber BD Comply Single fiber meet the requirement
Page 1, Catalog FC-6S
Coating diameter F 0.25mm, F0.9mm BD Comply F 0.25mm, F0.9mm Fiber Cleaver
Page 1, Catalog FC-6S
2 Cleaving angle <= 0.5o BD Comply 90°±0.5° Fiber Cleaver
The bidder commit to
3 Life time >50.000 time BD Comply >50000 time meet the requirement

4 Sample
2. Cable Stripper set ( included 1 knife and 1 stripper) CFS-2
Knife
Evaluated
No Specification Requirement Comply Technical Specification Reference
(BD/NBD
The bidder commit
Easy to grip body Comply Easy to grip body to meet the
requirement

The bidder commit


Rubber grip make easy Rubber grip make easy
Comply to meet the
opening operation opening operation
requirement
General requirement BD

The bidder commit


Spare blade is provided in the Spare blade is provided in
Comply to meet the
body the body
requirement
1
The bidder commit
Applicable cable meter F 8 to 28mm BD F 8 to 28mm to meet the
2 requirement

Sample

Stripper
Evaluated
No Specification Requirement Comply Technical Specification Reference
No Specification Requirement Comply Technical Specification Reference
(BD/NBD

Stripping 250um buffer Stripping 250um buffer Page 1, Catalog


coating to expose 125um Comply coating to expose 125um Fiber Optic Stripper
cladded fiber cladded fiber CFS-2
1 Applicable stripper BĐ
Stripping 2-3um fiber jackets Stripping 2-3um fiber Page 1, Catalog
Spare blade is provided in the Comply jackets Spare blade is Fiber Optic Stripper
body provided in the body CFS-2
For stripping 250 micron For stripping 250 micron Page 1, Catalog
buffer coating to expose 125 Comply buffer coating to expose Fiber Optic Stripper
micron cladded fiber 125 micron cladded fiber CFS-2
Page 1, Catalog
Second hole for stripping 2- Second hole for stripping
Comply Fiber Optic Stripper
3mm fiber jackets 2-3mm fiber jackets
CFS-2
140 µm diameter hole and
140 µm diameter hole and V-
V-opening in blade allows Page 1, Catalog
opening in blade allows
Comply removal of 250 micron Fiber Optic Stripper
removal of 250 micron buffer
buffer coating from 125 CFS-2
coating from 125 micron fiber
micron fiber

The bidder commit


Pre-set at the factory - no Pre-set at the factory - no
Comply to meet the
adjustments needed adjustments needed
2 Feature BD requirement
The bidder commit
Will not scratch or nick glass Will not scratch or nick
Comply to meet the
fiber glass fiber
requirement
All stripping surfaces are All stripping surfaces are
The bidder commit
manufactured to precise manufactured to precise
Comply to meet the
tolerances to assure clean, tolerances to assure clean,
requirement
smooth strips smooth strips
The bidder commit
Comfort-grip, ergonomic Comfort-grip, ergonomic
Comply to meet the
handles handles
requirement
The bidder commit
Lock to hold tool closed when Lock to hold tool closed
Comply to meet the
it is not in use when it is not in use
requirement

3 Sample
a
3. Heat shrink splice protector
No Specification Requirement Comply Technical Specification

1 Capacity 1 fiber
Comply 1 fiber

CLosure 24FO: 24 heats


2 Quantity 24 heats shrink splice
shrink splice protector
Comply protector
3 Dimension

3.1 Length 60mm ± 3mm


Comply 60mm ± 3mm

- Diameter : 1,3 ÷ 1,5 mm


Comply 1.5mm
3.2 Pipe iner
- Thickness: 0,3 ÷ 0,5 mm
Comply 0.5mm

- Diameter : 2,0 ÷ 3,0 mm


Comply Diameter : 2,0~3,0 mm
3.3 Pipe Outer
- Thickness: 0,15 ÷ 0,25 mm Thickness: 0,15 ~0,25
Comply mm

- Diameter: 1 ÷ 1,5 mm
Comply Diameter: 1~1,5 mm
3.4 Wire reinforced
- Length: 54 ÷ 56 mm
Comply Length: 54~56 mm

- Inner pipe: EVA Plastics


(Ethylene Vinyl Acetate)
Comply Inner pipe: EVA

- Outer Pipe: Polyolefin


4 Material Outer Pipe: Polyolefin
Plascis
Comply Plascis

- Reinforced rod: Stainless


steel
Comply Stainless steel 304

5 Temperature heat shrinkable 90oC ÷ 120oC


Comply -45℃ to 120 ℃
6 Radial heat ratio ≥ 50%
Comply ≥ 50%

7 Sample
Reference

Page 1, Catalog
Heat shrink splice
protector
The bidder commit
to meet the
requirement

Page 1, Catalog
Heat shrink splice
protector
Page 1, Catalog
Heat shrink splice
protector
The bidder commit
to meet the
requirement
The bidder commit
to meet the
requirement
The bidder commit
to meet the
requirement
page 2,catalog Heat
shrink splice
protector
page 2,catalog Heat
shrink splice
protector
The bidder commit
to meet the
requirement
The bidder commit
to meet the
requirement
The bidder commit
to meet the
requirement
Page 1, Catalog
Heat shrink splice
protector
The bidder commit
to meet the
requirement
4. Optical Connector Cleaning Tool CLE-PEN
Evaluated
No Specification Requirement Comply
(BD/NBD
Used to clean optical connector
Comply
or adapter
1 Describe BD
LC/SC/FC with PC, UPC &
Comply
APC standard

Core of cleaning tool


2 Material BD Comply
replaceable

Ability to operate much more


3 Life time BD Comply
500 times

4 Sample
Technical
Reference
Specification
Used to clean optical Page 1, catalog
connector or adapter CLE-PEN
LC/SC/FC with PC, Page 1, catalog
UPC & APC standard CLE-PEN

Core of cleaning tool The bidder commit


replaceable to meet the
requirement

Ability to operate The bidder commit


much more 500 times to meet the
requirement
5. OPTICAL FIBER SPLCIER- VIEW6L

Evaluated
No Specification Requirement Comply Technical specification Reference
(BD/NBD
I General Features

Technology: Core to Page 1, Catalog


Comply Core to core alignment.
core alignment. View 6L

- Automatic Adjustment The bidder


1 Fiber Alignment fiber and detect the fiber BD Comply Splice mode / Put fiber into commit to meet
type. holder the requirement

The bidder
- Can evaluate the
Comply commit to meet
quality of splicing Estimated loss
the requirement

Automatic arc calibration by Page 3, Catalog


2 Arc calibration Automatic BD Comply
air pressure and temperature View 6L

The bidder show details


The bidder
Evaluate the quality in document how to
3 BD Comply commit to meet
of splicing evaluation quality of
the requirement
splicing.

- Can display the process


of core to core alignment Pause 2
and splicing. The bidder
4 Monitor Display BD Comply commit to meet
- Splice attenuation. Splice mode the requirement
- Display fiber Cleave
Pause2
angle and surface.
Can operate under harsh
Operating Altitude: 0~5000m
environmental condition
above sea level, 0~95% Page 3, Catalog
5 Environment (high altitude, humidity, BD Comply
relative humidity, -10~50°C, View 6L
Have anti-shock
Max Wind 15m/s; IP52
protection cover ).

AC Input 100-240V, DC Input


Can work with Battery Page 3, Catalog
6 Operating condition BD Comply 9-14V
and Adapter AC/DC View 6L
5200mAh Battery Capacity

II Detailed Requirements

Color LCD monitor , ≥ Page 2, Catalog


NBD Comply 5” Touching Screen LCD
4" View 6L
“System
1 Display screen setting”- Page
Language: English BD Comply English 41, User
Manual of
View 6L

- Cameras (for X and Y)

2 cameras:
- X axial/ Y axial: 520x magnification for single Page 9, User
Fiber view and ≥300X magnification
2 BD Comply X or Y view, or 520x Manual of View
magnification
magnification for both X and Y 6L
view
- X axial and Y axial
simultaneously: (≥88X
magnification)

The buttons can control Page 16, User


The buttons can control with
3 Function buttons with all functions in BD Comply Manual of View
all functions in splicer
splicer 6L
Type of fiber:

- SM (Single mode ITU- - SM (Single mode ITU-T


Comply
T G.652/G.657) G.652/G.657)

- MM (Multimode ITU- - MM (Multimode ITU-T


Comply Page 8, User
T G.651) BD G.651)
Manual of View
- DS (Dispersion shifted - DS (Dispersion shifted ITU- 6L
Comply
ITU-T G.653) T G.653)
4 Applicable Fibers - NZDS (Non-zero
- NZDS (Non-zero dispersion
dispersion shifted ITU-T Comply
shifted ITU-T G.655)
G.655)
Dimension of fiber:
Page 8, User
- Cladding diameter:
Comply Cladding diameter: 80-150μm, Manual of View
80μm -150μm
BD 6L
Page 8, User
- Coating diameter:
Comply Coating diameter: 125-1000μm Manual of View
100μm - 1000μm
6L
- SM ≤ 0.02 dB SM : 0.02dB
Page 8, User
5 Splice loss - MM ≤ 0.01dB BD Comply MM : 0.01dB Manual of View
- DS ≤ 0.04 dB DS : 0.04dB 6L
- NZDS ≤ 0.04 dB NZDS : 0.04dB
Quick mode: 7s Page 3, Catalog
6 Splice time ≤ 9 seconds BD Comply
Auto mode: 9s of Vỉew6L
Page 8, User
7 Heating time ≤ 30 seconds BD Comply Typical heating time: 13s Manual of View
6L
5500 arcs, can be extended by Page 3, Catalog
8 Electrode life ≥ 2500 splices BD Comply
using an electrode grinder of View 6L

Lithium ≥ 200 (splice + Page 3, Catalog


Comply Typical :250 cycles
heat) cycles of View 6L

9 Battery - Battery is detachable BD Battery is detachable from Page 17, User


from main body of
Comply main body of splicer that can Manual of View
splicer that can easy to
easy to replace battery 6L
replace battery

Page 3, Catalog
10 Tension test ≥ 1.96N BD Comply 1.96~2.25N
of View 6L

Page 40, User


10000 records and 2000
11 Data storage ≥ 1000 results NBD Comply Manual of View
images
6L
See picture,
Fiber heater is assembled Fiber heater is assembled on page 16, User
12 Heater BD Comply
on main body main body Manual of View
6L

- Adapter AC/DC with


Page 3, Catalog
input: 100~240 VAC, BD Comply AC Input 100-240V
View 6L
50Hz.

13 Power requirement
13 Power requirement
- Adapter AC/DC is See Picture,
Adapter AC/DC is detachable
detachable from main BD Comply Catalog View
from main body of splicer
body of splicer 6L

Support DC input, Page 3, Catalog


NBD Comply DC Input 9-14V
Nominal 12 VDC View 6L
Page 3,Catalog
Ingress Protection: 52 or View 6L
BD Comply IP52
better

Altitude: 0 to 5000m Page 3, Catalog


NBD Comply 0~5000m above sea level
about sea level View 6L

Page 3, Catalog
Humidity: 0 ÷ 95% BD Comply 0~95%
Environment View 6L
14
condition
Operating temperature: Page 3, catalog
BD Comply -10~50°C
-100C÷ 500 C View 6L

Storage temperature: Page 3, Catalog


NBD Comply -40~80°C
-100C ÷ 600C View 6L

Weight Fusion
Page 3, Catalog
15 Splicer (included ≤ 3,0 kg BD Comply 2,43 kg
View 6L
Battery)
The bidder
- For cable diameter: - For cable diameter:
commit to meet
10mm~16mm 10mm~16mm
the requirement
16 Cable Shield Cutter. NBD Comply
- The blade can The bidder
- The blade can adjustable
adjustable depth of the commit to meet
depth of the cut
cut the requirement
- For fiber with Ø The bidder
- For fiber with Ø 0.25mm &
0.25mm & Ø 0.9mm Comply commit to meet
BD Ø 0.9mm diameter.
diameter. the requirement
- Cleave angle: ≤ 0,6° Comply ≤0.5°
High Precision Fiber
17 The bidder
Cleaver. Blade lifetime ≥ 48000
BD Comply 48,000 commit to meet
single-fiber cleaves
the requirement
Cleave Length: comply Page 3, Catalog
NBD Comply Cleave Length: 5~16 mm
5-16 mm View 6L
- Jacket fiber: Standard: Jacket fiber: Standard: Ø The bidder
Ø 0.25mm to Ø 0.9mm Comply 0.25mm to Ø 0.9mm diameter commit to meet
Jacket Stripper for diameter fiber fiber the requirement
900um OD &
18 BD
Primary Coat - Primary coat fiber: - Primary coat fiber: Standard: The bidder
Stripper. Standard: Ø 0.125mm to Comply Ø 0.125mm to Ø 0.25mm commit to meet
Ø 0.25mm diameter fiber diameter fiber the requirement

Applicable
Page 3, Catalog
19 protection sleeve 40mm & 60 mm BD Comply 20~60 mm
View 6L
length
- Store splicer and all - Store splicer and all
accessories. Have Comply accessories. Have shoulder
shoulder strap. strap.
The bidder
- Material: Plastic or
20 Hard Carrying Case NBD Comply Better commit to meet
Better
the requirement
- Weight: ≤ 3,0 kg Comply <3kg
- Anti-shock, divided Anti-shock, divided
Comply
components components
- Support Free software
for upgrade or result
Upgrade software, Analyzer (CD)
The bidder
download stored
21 BD Comply Result Analyzer x commit to meet
splice loss data from
the requirement
splicer
Upgrade software,
The bidder
download stored - Can download data
21 BD Comply Result Analyzer x commit to meet
splice loss data from (splicing related results)
the requirement
splicer from splicer to PC for
analyzing, storing
results.

+ 01 Set: Fusion Splicer


(include main
equipment, AC
adapter/Battery charger,
AC Power cord, clamp,
electrodes..).
+ 02 Pieces: Spare
Electrodes.
+ 01 Piece: Fiber holder
(assembled on the main
body)
+ 01 Piece: Heat
shrinkable tubing
cooling tray
+ 01 Piece: Hard
Carrying Case.
+ 01 Piece: Cable Shield
Cutter.
+ 01 Piece: Loose Tube
Cutter.
The bidder
22 Package content + 01 Piece: Jacket BD Comply commit to meet
Stripper for 900um OD the requirement
& Primary Coat Stripper.

+ 01 Piece: High
Precision Fiber Cleaver.
the requirement

+ 01 Piece: Alcohol
Dispenser.
+ 01 Piece: Spare
battery.
+ 01 Book: User manual
+ Accessory (CD
included free software
and user manual, All
cords for connect port:
USB cable...).
+ USB cable.
+ Adapter.
+All other necessary
accessories.
Use guide by document
and video with English
sub

22 Sample
6. Optical Time Domain Reflectometer - AQ7280

Evaluated Tài liệu trích


TT Specification Requirement Comply Technical Specification
(BD/NBD dẫn/Reference
A General requirement

Page1, Brochure
Testing method: Optical Time
Testing method: Optical Time Domain AQ7280 Series
1 BD Comply Domain Reflectometor
Reflectometor (OTDR). Optical Time Domain
(OTDR).
Reflectometer

Measurement Result
Measurement Result requirement: requirement: Automatically
Page10, Brochure
Automatically detect and display detect and display events by
AQ7280 Series
events by trace diagram and event Comply trace diagram and event
Optical Time Domain
parameters. Support Graphic view for parameters. Support Graphic
Reflectometer
easier to detect and locate events. view for easier to detect and
locate events.

Event display: Distance,


2 - Event display: Distance, attenuation BD attenuation (include attenuation Page 7, User’s
(include attenuation event, attenuation event, attenuation total), return Manual IMAQ7280-
Comply
total), return loss with separate icons loss with separate icons for 01EN
for distinguish one event from another. distinguish one event from
another.

Page 7, User’s
Events can be located is: Splicer,
Splicer, connector, splitter, Manual IMAQ7280-
connector, splitter, Reflective, End of Comply
Reflective, End of Fiber. 01EN
Fiber.
OTDR Tester support the manual and OTDR Tester support the Page 2, Brochure
-auto
Automatic mode: mode:
measurement the parameters are
manual and auto measurement AQ7280 Series
3 set automatically and in according to BD Comply
-the
Manual mode: User can set suitable mode: Optical Time Domain
distance.
parameters for measurements. Automatic & manual Reflectometer
Can display and mix at least
Can display and mix at least two trace
two trace diagram
diagram simultaneously, compare trace Page 19, Brochure
simultaneously, compare trace
by mixing same direction trace. AQ7280 Series
4 BD Comply by mixing same direction trace.
Optical Time Domain
OTDR can calculate and display OTDR can calculate and Reflectometer
splicing loss by mixing bi-direction display splicing loss by mixing
trace. bi-direction trace. Page 11, Brochure
Monitor fiber in real - time AQ7280 Series
5 Monitor fiber in real - time mode BD Comply
mode Optical Time Domain
Reflectometer
- Support Macro bending detection: dis Page 6, Brochure
play distance, attenuation and icon to AQ7280 Series
Comply Support Marco bending
distinguish macro bending from Optical Time Domain
another event. Reflectometer
6 BD
Page 11, Brochure
AQ7280 Series
- Support remote monitoring function. Comply Remote monitoring function
Optical Time Domain
Reflectometer

B Detail technical requirement


I Main Frame Requirement

Page 10, Brochure


Color screen, ≥ AQ7280 Series
BD Comply 8.4 inch
6 inch. Optical Time Domain
Reflectometer
1 Display screen
Screen Page 10, Brochure
Resolution: AQ7280 Series
BD Comply 800 × 600
640x480 or Optical Time Domain
higher Reflectometer
Page 12, Brochure
AQ7280 Series
2 Language English BD Comply Multi English
Optical Time Domain
Reflectometer

Page 10, Brochure


AQ7280 Series
3 Distance Units Km BD Comply km, mile, kf
Optical Time Domain
Reflectometer

Page 10, Brochure


1,40000 to
Group index range 1.30000 to 1.79999 (in 0.00001 AQ7280 Series
4 1,60000 in BD Comply
setup steps) Optical Time Domain
0.0001 steps
Reflectometer
page 32, User Manual
Number of data
≥ 120.000 data of AQ7280 Series
5 points (Horizontal BD Comply 256.000 points
points Optical Time Domain
axial)
Reflectometer
Page 10, Brochure
≥1000 test AQ7280 Series
Internal Memory NBD Comply ≥1000 waveforms
results Optical Time Domain
Reflectometer
6
Page 10, Brochure
Can copy via AQ7280 Series
External Memory BD Comply USB memory, SD card
USB Optical Time Domain
Reflectometer
Power Supply
Page 11, Brochure
AC Input:
100 to 240VAC, 50/60Hz (AC AQ7280 Series
AC/DC Adapter 100~240V, 50- BD Comply
adapter) Optical Time Domain
60Hz
Reflectometer

7
Page 11, Brochure
- Type:
AQ7280 Series
Rechargeable Comply Lithium-ion
Optical Time Domain
Lithium
7 Reflectometer
Page 11, Brochure
- Operation
AQ7280 Series
Battery time≥ 4 hours BD Comply 15 hours
Optical Time Domain
continuous
Reflectometer
Page 11, Brochure
AQ7280 Series
- Easy to replace Comply Yes
Optical Time Domain
Reflectometer
Operating −10 to 50˚C (0 to 40°C when Page 11, Brochure
temperature: AC adapter is being used. 0 to AQ7280 Series
BD Comply
cover range 0°C 35˚C when the battery is be Optical Time Domain
to 50°C charged) Reflectometer
Page 11, Brochure
Shell protects AQ7280 Series
8 Environment BD Comply Yes
against impact Optical Time Domain
Reflectometer
Storage Page 11, Brochure
temperature: AQ7280 Series
NBD Comply −20 to 60˚C
cover range Optical Time Domain
-10°C to 50°C Reflectometer
Page 11, Brochure
0 to 90% RH (20 to 90% with
AQ7280 Series
9 Humidity 0% to 85 % BD Comply 739871 AC adapter, non-
Optical Time Domain
condensing)
Reflectometer
Approx. 2.2 kg (including Page 10, Brochure
internal battery and protectors, AQ7280 Series
10 Weight £3.5 kg BD Comply
excluding OTDR unit and Optical Time Domain
options) Reflectometer
Anti-shock The bidder commit to
11 Anti-shock BD Comply Anti-shock cover
cover meet the requirement
II OTDR Modules Requirement
Page 10, Brochure
Center
AQ7280 Series
wavelength: BD Comply 1310, 1550
Optical Time Domain
1310, 1550
Reflectometer
1 Wavelength (nm)
Page 10, Brochure
AQ7280 Series
Deviation: ≤ 25 BD Comply ±25
Optical Time Domain
Reflectometer
At 1550nm:
Page 9, Brochure
≥36 dB for AQ7280 Series
Comply 46
access network Optical Time Domain
BD Reflectometer
Page 9, Brochure
≥45dB for
AQ7280 Series
backbone Comply 46
Optical Time Domain
network
Dynamic range Reflectometer
2
(RMS) At 1310nm:
Page 9, Brochure
≥38 dB for AQ7280 Series
Comply 46
access network Optical Time Domain
BD Reflectometer
Page 9, Brochure
≥46dB for
AQ7280 Series
backbone Comply 46
Optical Time Domain
network
Reflectometer
Page 10, Brochure
AQ7280 Series
3 Event Dead zone £2m BD Comply 0.5 - 0.6
Optical Time Domain
Reflectometer
Page 10, Brochure
Attenuation Dead AQ7280 Series
4 £8m BD Comply 3.5/4 (4.4)
zone Optical Time Domain
Reflectometer
Page 10, Brochure
cover range 3, 10, 20, 30, 50, 100, 200, 300,
AQ7280 Series
5 Pulse width from 5ns to 20 BD Comply 500, 1000, 2000, 5000, 10000,
Optical Time Domain
µs 20000
Reflectometer
Page 10, Brochure
cover range 3, 10, 20, 30, 50, 100, 200, 300,
AQ7280 Series
6 Distance range from 2 to BD Not Comply 500, 1000, 2000, 5000, 10000,
Optical Time Domain
200km or longer 20000
Reflectometer
Attenuation Page 10, Brochure
accuracy AQ7280 Series
BD Comply ±0.03 dB/dB
(dB/dB): ≤± Optical Time Domain
0.05 Reflectometer

7 Accuracy Distance
accuracy (m) ≤ Page 10, Brochure
±(0.75 m + Measurement
± (1+ distance x AQ7280 Series
BD Comply distance × 2 × 10−5 +
3 x 10-5 + Optical Time Domain
Sampling resolution)
sampling Reflectometer
resolution)

Page 10, Brochure


AQ7280 Series
Min Sampling Comply 2 cm
8 ≤5cm BD Optical Time Domain
resolution Reflectometer
Auto or Cursor
Distance & (can use 2 point
attenuation method for User’s Manual
9 BD Comply
measurement measuring IMAQ7280-01EN
Function distance,
attenuation..)

Page 10, Brochure


Universal Adapter SC, FC, LC, AQ7280 Series
FC , SC adapter Comply
and SC Angled-PC Optical Time Domain
Measurement Reflectometer
10 BD
connector type Page 10, Brochure
Can be unplug
AQ7280 Series
to replace and Comply
Optical Time Domain
clean
Reflectometer
Free software
for upgrade or User’s Manual
11 Software BD Comply Free software
result Analyzer IMAQ7280-01EN
(CD)

12 Sample

You might also like