You are on page 1of 253
ETL600 ican Eaton Noverber 2005 Digital Power Line Carrier System Instruction Manual AbD © 2005 ABB Switzerland Lid Baden Release Date 2005-05-27 2 Edition 2005-08 | 3° Edition 2005-11-17 This instruction manual applies to the ETL600 Release 1.0 system We reserve all rights to this document, even in the event that a patent is issued and a different commercial proprietary right is registered. Improper use, in particular reproduction and dissemination to third parties, is not permitted. This document has been carefully checked. If the user nevertheless detects any errors, he is asked to notify us as soon as possible. The data contained in this manual is intended solely for the product description and is not to be deemed to be a statement of guaranteed properties. In the interests of our customers, we constantly seek to ensure that our products are developed to the latest technological standards. As a result, itis possible that there may be some differences between the product and the product description or the instruction manual. ABB Introduction Safety Instructions Structure and Function User Interface Program Configuration and Set-up Assembly and Installation Commissioning Operation and Maintenance Troubleshooting 10. Storage, Decommissioning and Disposal 11. Options Annex T1600 4KHWO01488-EN ABB Switzerland Ltd Contents i INTRODUCTION. of Using the manual ae Application of the ETL600 43) Requirements to be met by the operator... 14. Requirements to be met by the service personnel 15. Guarantee provi 2 SAFETY INSTRUCTIONS. ay Safety information... 244. In this instruction manual 241.2 (On the equipment. 22, 23, 24, 3 STRUCTURE AND FUNCTION. 34. Introduction... 344 APLC and DPLC services greatataa Soa 33 341.2. Frequency allocation in AF channels 37 32. ‘System architecture. 324 Digital signal processing .... 316 322 Analog signal processing ae 316 33. Module description 3341 AF interface O4LE. 33.1.1 PROMI caste ccssetostsiain 332 Teleprotection interface G4Al 33.21 ‘Summary. so 33.22 IOPUtS nn 3.3.2.3. Solid state outputs. 33.24. Relay outputs . 33.25, FrOntplate nnn 3.3.3. RF-Converter PAL: 3334 Frontplate P4LT.... 33.4. RF-Converter P4LU 3.3.4.1 Frontplate P4LU..... 3.35. Alarm relay module R1BC. Contents| November 2005) 1 ABB Switzerland Ltd 1KHW001489-EN ETL600 336, 3.37. 3.38. 3.3.9. 3.3.10 33.11 3.3.12. 3.3.13. 3.3.14, 34. 3.4.1. 34.1.1 3.4.1.2 3.4.1.3, 3.4.1.4. 34.1.5, 34.16, 3.4.17, 34.2. 3.4.21 3.4.22 343, 3.5. 354 3.5.1.4 3.5.1.2. 3.5.2. 353, 35.3.1 35.3.2, DC-DC converter BALE Channel subrack P7LC 40 W power amplifier P1LA, Transmit fter ESTX Carrier combiner P3LG..... RF hybrids P3LE, dummy load P3LK... Receive Filter PARX Power supplies BSLA and BSL Power subrack P7LA. Analog Services. Telephony... Point to point hot line (di Remote subscriber..... 4-wire PAX connection with E&M signalling ; 2/4-wire PAX connection with E&M Asoraling en hybrid control..3-40 phone) E&M signaling 344 ‘Service phone ? - 344 Display E&M Signaling a at front LEDs 3-41 Teleoperation . 2 Ports... 3-42 ‘Transit fters...... 3-43 External teleprotection .... 344 Data Communication .. NSK600 Modern....... Data Regeneration with FSK Modems Required data transmission format parameter for DAPSK . MOD600 Modern... MUX600 DPLC Channel Multiplexer and V.24 Port * Sharing. DPLC Channel Multiplexer. 3 V.24 Port Sharing... Data Port Interfaces secu G.703 (not supported with ETL600 Release 1)... MeN ect . V.24... Internal Teleprotection Introduction... Intended use of NSDEO0 Structure of NSD6OO. Features... Applications Permissive Tripping Scheme: Direct Transfer Tripping ........ Blocking Scheme: = Unblocking ...... a Protecting Dual-Circuit Lines. Protecting Single-Circuit Lines... 363 Phase Segregated Line Protection... 3-65 Relaying Tripping Signals Through Intermediate Station 365 November 2005, Contents ETL600 ‘1KHWW001489-EN ABB Switzerland Lid 368. Performance criter 3664 General 3.662 Transmission time 6. Nominal transmission time (T0) 3.66822. Maximum actual transmission time (Tac) 3663. ‘Security 3.66.4. Dependability... 367. Operating principle. 368. Functional description .. 3.6.8.1 GeNETA nese 36.82. Speech bandwidth... 3683. Guard signal 36.84. Command signals 3.6.8.4.1. — Dualtone principle... 3.6842. Trip frequencies 3.6.84.3. Command assignment to trip frequencies 3685. Boosting... : 3.8.86. Input/Output Command Handing. 3.6.8.6.1. General 38862. Tx Input Command Delay... 3.6863. Tx Input Command Prolongation .. 36.864. Tx Trip Duration Monitoring... Snel 3.6.8.65. Rx Output Command Duration. : senna STD 3.6.8.66. Rx Output Command Prolongation .... 36.867. Rx Trip Duration Monitoring 3887. Start Inputs... 36.88. Unblocking EBM hs 3.6.8.9. Command Outputs During Link Failure... 381 3.8.8.10. Tx Command Acknowledge ..... 3-82 36.811. Rx Guard Signaling 3.68.12, Blocking of AGC. 3.88.13. Cyclic Loop Te : 3.8.8.14. Manual Loop Test 3.68.15. Local Test Mode 3.88.16. Command Counters. 368.17. Alarms Sources. a 368.18. Alarm /Waming Contacts... 3.6.8.19. __ Interference in Speech Band.... ial etd 36.820. Compatibility with Inband Modem Signals... 3.87 36.821. 3 APLC in 8 kHz Operating Mode with NSD600.. ‘nn BT 37. Event Recorder. 374 General. 372 NSD800 Command Events 373 Alarm, Warning & Manipulation Events. 374 Upload events. 375 Upload counters. 376 Reset counter... 377 Set clock... 378 RTC synchronization from an external clock. 379. Views. se Contents ‘November 2005 it ABB Switzerland Ltd 4KHW001489-EN ETLs00 37.9.1, 3.7.9.2. 3.7.9.3. 3.7.9.4. 37.95 3.7.96. 3.7.9.7. 4 4a. 42. 424 Text view... Graphic view ...... Set up the views... Zooming the Graphic View. Scrolling the Graphic View Right mouse bution Import events into a spreadsheet or word processing tool USER INTERFACE PROGRAM Introduction Installation .. System requirements Install HMI600.... Using HMI600. Communication to the ETL600 Specifying a Write password. Direct connection via cable Communication media ‘Communication settings. Logon to the equipment Communication via phone modems. Communication media ‘Communication settings ie ‘Configuration of the modems. Configuration of HMI600.... Logon to the equipment Communication via intranet/internet. Communication media ... ‘Communication settings. ‘Configuration of SVR600 Configuration of HMI600 Logon to the equipment Connection via intranet/internet and Prone modems. - Communication media . Communication settings. Configuration of SVR600 Configuration of HMI600 Logon to the equipment Element management networks RS-485 station bus..... Embedded specaion channel (EOC). Network protocol... Operation .. November 2005 Contents, 4KHWW001480-EN ABB Switzerland Lid Data management. 14 Compatibility 415 ETLG00 releases, release numbers, version numbers, type codes 4-15 Compatibility between modules of a PLC terminal. Compatibility between the two ETL600 terminals of a link Compatibility of HMI600 to ETL600 terminals. Compatibility of HMI600 to configuration files Uninstalling HMI600... 6 CONFIGURATION AND SET-UP. 54. Introduction 52. Systems level and level stirs 524 Power definitions 5244 Mean power 5212 Peak power.. 5.2.1.3, Peak envelope power (PEP). 522 Voltage definitions: 5224 RMS voltage. 5.2.22 Peak Voltage ...nnnnennnn 5.2.2.3, Peak envelope voltage... .nenm 523. scent ral Seared Sora Processing 5231 Absolute power level... 5232 Absolute peak power level 5.2.3.3, Absolute peak envelope power (PEP) level.. 5234. ‘Absolute voltage level 5235, Absolute peak voltage level... 5236 ‘Absolute peak envelope voltage level, 524. ‘Absolute level definitions - digital signal processing .. 5.25. Absolute psophometrically weighted level Lop {eemop} 526. Conversion between power and voltage levels... 527. System power level Lo [dBmd].. 528 Relative poe evel 529. Level measurements... 5.2.10. Signal weights... 5211 The S-value 5.2.12 Weight of the MOD600 signal. 52.13 ‘Weight of the NSD600 guard signal 5.2.14. Internal teleprotection devices NSD600........ . il 5.2.15. External teleprotection device NSD570/NSO70C 511 5,215.1. Guard signal of extemal NSDS70/NSD70C. 514 5.2152. Command signal of external NSDS70/NSD70C. 511 5.2.15.3. Persistent command transmission with external NSD570/NSD70C 5-12 5.2.16. Signal boosting for teleprotection devices. Foe iol 5-12 5.2.16.1. __Disconnectable and non-disconnectable ports or signals 5-12 5216.2. Boost Ratio...... Eornd 5-13 5216.3. Priority rules for boosting . 5-13 Contents November 2005 v ABB Switzerland Lid ‘JKHWO01489-EN ETLe00 5.3. 534. 5.3.4.4 5.3.1.2, 53.1.3, 5.3.1.4 5.3.2 53.21 5.3.3. 534. 53.41 5.3.4.2 5343. 5.3.44. 534.5 5.35. 5.3.5.1 5.3.5.2, 53.5.3, 5353.1 5.3.5.3.2 5.35.33. 5.3.54. 5g5S. 5.4. 6. 6.1. 62. 62.1. 6.2.2 623. 6.3. 6.31 6.4. 6.4.1 6.4.2, 64.3. Configuration with HMI600....... Configure services ‘Type.... Data communication 3 APLC channels 1, 2 and 3... Internal teleprotection. Configure System. Equipment Settings. Configure NSD600 Configure Analog Services. Configure telephony. Level settings of teleoperation ports, introduction Configure teleoperation port not used for transit operation 5-20 Configure teleoperation port used for transit operatic 5:24 Configure teleoperation port used for external teleprotection..... 6-23 Configure Data Communication 5-23 Data Communication Services... 5-24 Assignment of Data Ports to the Modems. 5-24 Data Port Parameter .703 port V.11 ports... V.24 ports... NSK600 modem, MOD600 modem. Use of HMI600 files .. ASSEMBLY AND INSTALLATION Safety instructions Unpacking and transport. Inspection upon receipt ‘What to do if there is transport damage Precautions to avoid transport damage . Installation .. Place of installation and ambient conditions Cabinet, Grounding system Installing racks in cabinets .. External cables... Coaxial Cable... Interfaces... AF Interface O4LE..... November 2005 Contents ETL600 ‘1KHW001489-EN ABB Switzerland Ltd 66.31.41. Telephony... 6-16 66.3.1.2. —Teleoperation . 616 6.6.3.2 Teleprotection interface G4Al BAB 66.3.3 RF Converter P4LT/P4LU 8-21 663.31. — V.11 cable VOW. so 66.332. — RS.232/ V.24 cable VOU. 6-22 66.3.3.3. RS-485/ IRIG-B cable V9OV...... 6-24 66.3.3.4. Alarm relays cable VOT 6-25 66.3.4. Relay Module R1BC..... 6-28 66.3.5. Remote inquiry kit R7AP 6-28 gs COMMISSIONING... #41 Safety instructions. 72. Checking the line of communication 724 Return loss J 722. Line attenuation... 73. ‘Commissioning of the PLC equipment. 73.4 Preliminary tests and checks 73.2. Tests according to the commissioning instructions 79 8 OPERATION AND MAINTENANCE a4. Safety instruction 8.2. Operation... 824 Normal Operation. 822 Faulty Operation... 8.3. Maintenances 83.1 Periodic functional checks. 86 83.11 Check input power supply voltage 86 8.3.12. Check alarm status for ETL600 element management networks ... 8-6 83.1.3 Check alarm events ~ edie 87 83.14. Check status data... 87 83.1.5. Check frequency response 87 83.16. Check AF levels... 83.17, ‘Check NSDE00 functions ... 9. TROUBLESHOOTIN 94. Safety instructions. 9.2. Fuses. 9.3. Alarms. 93.4 Alarm concept 9.3.2. Warnings cco Contents November 2005 vil ABB Switzerland Ltd ‘1KHWO001489-EN ETLs00 933, 93.4, 935, 936. 937. 937.4 93.7.2. 9.3.7.3, 93.7.4, 938. 9381 9.3.82 93.8.2.1. 938.22. 93.823. 93.8.2.4 9.3.8.3 9.3.8.3.1. 9.3.8.3.2, 93.833, 9.3.83.4, 93.9, 9.3.10, 9.4. 94.1 94.1.4 9412 9.4.1.3. Grouping of alarms Affected services, Affected hardware Alarm source... Alarm hierarchy. Top-level alarmsiwarnings..... High-level alarmsiwarings... Low-level alarmsiwarnings. Detail alarmsiwarnings.. Alarm outputs....... Alarm LED on Gaal. Alarm LED on O4LE. Alarm LED on RF hybrid and on RF Combiner. Alarm relays Alarm relays on Patt. Alarm relays on R1BC... Alarm relays on G4Al Alarm relay on O4LE. ‘Alarm polling Alarm event recorder. ‘Some basic checks... Internal teleprotection suber Loop test... . Local test mode. Event Recorder and Command Counters. Frequently asked questions. List of alarms and corrective actions.. PLCrace: PLC hardware alarm . PLC link alarms...... PLC interface alarms... PLC warning: O4LE detail alarms. O4LE detail wamings . Data... Data hardware alarms. Data link alarms Data interface alarms Data warnings TPE TPE hardware alarms ...... TPE link alarms... TPE interface alarms, TPE warnings... G4Al detail hardware alarms. November 2005 Contents ETLs00 4KHWO001489-EN ABB Switzerland Ltd 96.36 G4A\ detail interface alarms. te 9-28 9.6.37 G4A\ detail warnings 9-29 964. ‘TDM Bus communication alarms and waming: 9-29 97. Replacement of faulty items 9-29 10. 10.1. 10.2. Dispatch for repairs Support STORAGE, DECOMMISSIONING AND DISPOSAL, Decommissioning 10.4. Disposal. 1. OPTIONS 14. Basic equipment. 11.2. Optional equipment 1124 Opti PONE wee acrnceccamnanmnanctingnencronsnccnacriacinel tl 11.21.41, AF interface type O4LE....... Pee Ne sical 11212 Teleprotection interface type G4Al.. 14-4 11.21.3. Interface extension module P1LX 11-4 11.214. Alarm relay module type R1BC.... 11.2.4.5, Dummy 10ad PLK nnn 8 acess eB 11218. Cables...... reared TD 1122 Optional facilities... . coed B, 11.221. User Interface Program... 11-3 11.222. Cabinet type E40A with accessories. ood 4-3 11.223. Personal Computer... AV 11.224. PC connection set... 11-3, 11.225. RF connection plate ACS... A138 11.226. Filter tuning set... - 14-3 11.2.2.7. Krone 1001 Kit nnn a M43 11.22.8. Remote inguiry kit R7A\ ANB 11.229. Service Telephone Q8AB. 14-4 11.3. License: AA Contents November 2005, ik ABB Switzerland Lid 1KHWO001489-EN ETL600 List of Figures Fig Fig, Fig. Fig. Fig. Fig. Fig. Fig. Fig Fig Fig, Fig. Fig, Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig. Fig, Fig Fig. Fig. Fig. Fig. 34 Fig. 3-2. Adjacent (a) and non-adjacent (b) frequency bands ......3-2 Fig. 33 a4 35 37 38 39 3-10 at 312 313 314 315 316 347 318 3419 3:20 3:21 3-22 3:23 3:24 3:25 3:26 3.27 3-28 3:29 3-30 ETL600 with a wide range of services.. 32 Use of nominal frequency band for pure APLC (a), pure DPLC (b) or mixed APLC/DPLC (c) operation in ETL600 erect mode. nverensen Use of nominal frequency band for pure APLC (a), pure DPLC (b) or mixed APLC/DPLC (c) operation in ETL600 inverted mode Typical frequency allocation in a 4 kHz AF channel. Use of ETL bandwidth for a 4 kHz AF channel..... Use of ETL bandwidth for a 3.2 kHz AF channel Use of ETL bandwidth for a 2.4 kHz AF channel ETL640/680 configurations ...... - Functional block diagram ETL640 with Rx filter... Functional block diagram ETL640 without Rx filter .:..3-44 Functional block diagram ETL680 Frontplate O4LE Frontplate G4AN Frontptate P4LT. Frontplate P4LU...... RIBC Block Diagram PALA Block Diagram ESTX block diagram 80 WRF front end with combiner... P3LG block diagram. Block diagram RF hybrid P3LE — The two possible topologies of the RF front end... Block diagram of the Rx fiter PARX Block diagram of P7LA equipped with BSLA, FOTX, PILA, PSLE Point to point hot line. 2.wire remote subscriber. 4-wire remote subscriber... - 3:39 4-wire PAX connection with E&M wo B40 2/4-wire PAX connection with E&M and hybrid control ..3-40 34 November 2005 Contents ETL600 1KHWO01488-EN ABB Switzerland Ltd Fig. 3-31 Service phone = Fig. 3-32 State of LEDs connate to internal E&M.. Fig. 3:33 State of LEDs showing to internal E&M when one PAX is not working correctly oa ig STi ch retlnciosSotectable in ste of 60 Hz... a ies Fig. 3-35 Transit connection... Fig. 3:36 MUX600 Block Diagram... Fig. 3.37 DPLC Channel Multiplexer Framing so Fig. 3-38 Redundant protection of a dual-circuit line Fig. 3-39 Duplicated protection for a single-circut line.. Fig. 3-40 Examples for allocation of the 4 kHz band with speech and the ETL600 pilot as NSD600 guard signal .......3-74 Fig. 3-41 Examples for allocation of the 4 kHz band with speech and an own NSD600 guard signal. 43-74 Fig. 3-42 Dual-tone principle . t 3-75 Fig. 3-43 Inputoutput command handling parameters 3-78 Fig. 4-1 Communication via cable «00 43 Fig. 4-2 Communication via phone modems ...n..0nnernrsnnenl eS Fig. 4-3 Communication via intranet/internet nn Fig. 4-4 Communication via intranet/internet and phone modems ..4-9 Fig. 4-5 RS-485 station bus with R7AP oN Fig. 4-6 Embedded operation channel Fig. 4-7 Chain of ETL600 links oe ee Fig. 4-8 Example of an element management network... Fig. 4-9 Data-Management, Data-Flow Fig. 4-10 HMI600 compatibility relations 4-11 Compatibility relations for HMI600 0 configuration fi files 4-17 5-1 Signal levels from AF terminal to RF terminal... 519 . 5-2 Data in relation to clock signal se 25 Fig. 6-1 Front view of the ETL640 equipment equipped with Wiebe OAL (ots Nt Sn N22), G4Al alts NzB and N71)... 67 Fig. 6-2 Front view of ETL640 mounted in a cabinet type E40A.....6-8 Fig. 6-3 ETL640 equipment rear view 88 Fig. 6-4 Front view of ETL680 mounted in a cabinet type E40A.....6-9 Fig. 6-5 ETL680 equipment rear view... oe) Contents November 2005: x!

You might also like