Professional Documents
Culture Documents
Required Data
size of colunm=
l= 0.432 m 17
b= 0.432 m 17
Bearing Capacity of Soil= 150 KN/m²
Strength of Steel (fy)= 500 N/mm²
Strength of Concrete (fck)= 20 N/mm² ( M 20 )
Axial Load = 617 KN
Eccentricity of loading (ex) = 0.000 m 0
Eccentricity of loading (ey) = 0.000 m 0
Adopted size=
L= 2.134 m 7
B= 2.134 m 7
Actual area of footing = 4.552249 m²
Net Pressure acting upwads = 203.31 KN/m²
B. M. at the face of column about an axis 74 KN-m/m
(Per unit meter width)
Adop. D= 407 mm
The critical section is taken at distance d away from the face of column
The critical section is taken at a distance of 0.5d away from the face of column ,
Shear force Vu= 782.59 KN
Nominal Shear Stress(Tv) = Vu/b'd (Where b' is the periphery of critical section )
and b' = 3353.659 mm
from d+l
f
f
4.400019 in
8 LOOK GREY COLOR ABOVE IT AND INPUT IN DESIRE
Interpolation % Tc
Upper value 0.15 0.28
Required value 0.183 0.306047
Lower value 0.25 0.36
9.127935 in
6 in
om material property