Professional Documents
Culture Documents
Getting Started
1
In this Chapter...
Introduction................................................................................................................ 1-2
Conventions Used....................................................................................................... 1-3
Product Overview....................................................................................................... 1-4
Agency Approvals....................................................................................................... 1-5
Part Number Key........................................................................................................ 1-5
Product Label Examples:............................................................................................ 1-6
Serial Number and Date Code formats:.................................................................... 1-6
Quick Start Steps........................................................................................................ 1-7
Step 1 – Unpack and Inspect..................................................................................... 1-7
Step 2 – Install Optional Hardware Accessories.......................................................... 1-8
Step 3 – Become Familiar with Available Communication Ports................................. 1-9
Step 4 – Install C-more Micro-Graphic Panel........................................................... 1-10
Step 5 – Install the Programming Software and Develop a Project.......................... 1-11
Step 6 – Connect C-more Micro-Graphic Panel to Computer.................................. 1-12
Step 7 – Provide Power to the C-more Micro-Graphic Panel................................... 1-13
Step 8 – Accessing the C-more Micro-Graphic Panel Setup Screens........................ 1-14
Step 9 – Choose C-more Micro-Graphic Panel to PLC Protocol & Cables................ 1-15
Step 10 – Connect C-more Micro-Graphic Panel to PLC......................................... 1-16
Chapter 1: Getting Started
Introduction
1 The Purpose of this Manual
Thank you for purchasing our C-more® Micro-Graphic family of products. This manual
2 describes AutomationDirect.com’s C-more Micro-Graphic panels, their specifications, included
components, available accessories and provides you with important information for installation,
3 connectivity and setup. The manual shows you how to install, wire and use the products. It also
helps you understand how to interface the panels to other devices in a control system.
4 This user manual contains important information for personnel who will install the panels
and accessories, and for the personnel who will be programming the panel. If you understand
control systems making use of operating interfaces such as the C-more Micro-Graphic panels,
5 our user manuals will provide all the information you need to get, and keep, your system up
and running.
6 Supplemental Manuals
If you are familiar with industrial control type devices, you may be able to get up and running
7 with just the aide of the Quick Start Guide that is included with each panel and accessory. You
may also have need to refer to the On-line help that is available in the C-more Micro-Graphic
8 programming software. The Quick Start Guide is included with each accessory that will help
with installing the accessory.
9 Technical Support
We strive to make our manuals the best in the industry. We rely on your feedback to let us
10 know if we are reaching our goal. If you cannot find the solution to your particular application,
or, if for any reason you need technical assistance, please call us at:
11 770–844–4200
Our technical support group will work with you to answer your questions. They are available
12 Monday through Friday from 9:00 A.M. to 6:00 P.M. Eastern Time. We also encourage you
to visit our web site where you can find technical and non-technical information about our
products and our company.
13 http://www.automationdirect.com
14 If you have a comment, question or suggestion about any of our products, services, or manuals,
please fill out and return the ‘Suggestions’ card that was included with this manual.
A
B
C
D
®
Conventions Used
1
When you see the “notepad” icon in the left-hand margin, the paragraph to its immediate right will be a
2
special note. The word NOTE: in boldface will mark the beginning of the text.
3
4
When you see the “exclamation mark” icon in the left-hand margin, the paragraph to its immediate 5
right will be a warning. This information could prevent injury, loss of property, or even death (in
extreme cases). The word WARNING: in boldface will mark the beginning of the text. 6
7
8
Key Topics for Each Chapter
The beginning of each chapter will list the key topics Getting Started CHAPTER 9
that can be found in that chapter. 1
In This Chapter...
10
General Information .................................................................1-2
Specifications ...........................................................................1-4
11
12
13
14
A
B
C
D
®
EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17
1-3
Chapter 1: Getting Started
Product Overview
1
Touch Non
2 Screen Touch
3
4 EA1-S3ML, EA1-S3MLW* EA1-S3ML-N, EA1-S3MLW-N*
5 C-more Micro-Graphic 3.1-inch Panels have an STN LCD, 128 x 64 dot monochrome
display. Models EA1-S3ML and EA1-S3ML-N have 5 selectable backlight colors (green,
6 red, amber, yellow and lime). Models EA1-S3MLW and EA1-S3MLW-N have 5 selectable
backlight colors (white, pink1, pink2, pink3 and red). The panels have 5 user-defined
functions keys with LED indicators. The panels can display up to 10 lines by 32 characters
7 of static text and up to 10 lines by 21 characters of dynamic text with embedded variables
and phrases mixed with graphics. Power is supplied to the panel through the serial
8 communication port connection when used with AutomationDirect CLICK and most
DirectLOGIC PLC’s having a RJ12 communication port. Either EA-MG-SP1 (power supply
with serial port option module) or EA-MG-P1 is required when connecting to third party
9 PLC’s. NEMA 4/4X, IP-65 rated (when mounted correctly). For indoor use only.
Other features include:
10 • 768 KB memory
• Built in RJ12 serial communications port
11 • Adjustable contrast
• 2 optional keypad bezels, 8-button or 20-button
12 • 2 optional DC Power Adapters, one includes 15-pin serial communications port (RS-232/422/485)
• Optional replaceable clear screen overlay
13 • Built in Alarm Control setup that activates beep, backlight flash, customized alarm banner, and red
LED blinking
14 • Up to 999 screens, limited only by memory usage
• 0 to 50 °C (32 to 122 °F) operating temperature range
A • UL, cUL, CSA & CE agency approvals (see following table for details)
• 2-year warranty from date of purchase
B *Note: C-more Micro-Graphic panels with the letter “W” in the part number designate units with five
selectable background colors of White, Pink1, Pink2, Pink3 and Red. Part numbers without the letter “W”
C are provided with five selectable background colors of Green, Red, Amber, Yellow and Lime.
D *Note: Software and Firmware Version 1.5 or later is required with models EA1-S3MLW and EA1-
S3MLW-N. Available for free download at www.automationdirect.com
Agency Approvals
UL/CUL/CE Certification Numbers 1
Name UL/CUL UL508 CSA CE ISO-9000
C-more Micro-Graphic Panels
& Accessories E157382 E157382 234884 EN61131-2 Yes 2
C UL
R
US
3
4
Part Number Key 5
The C-more Micro-Graphic panel part numbers use the following key:
13
14
A
B
C
D
®
Function Key
b.) Unpack any accessories that
have been ordered, such as:
5
Label Insert
Mounting
Keypad Bezel, DC Power
Adapter, programming cable, 6
communications cable, etc.
Clips
c.) Inspect all equipment for 7
completeness. If anything
is missing or damaged,
immediately call the
8
AutomationDirect® returns
department @ 1-800-633-0405. 9
Cutout 10
Template C-more
Micro Graphic
Panel
11
12
Shipping Carton Contents
13
Optional Accessories 14
8-Button Keypad Bezel
EA-MG-BZ1
20-Button Keypad Bezel
EA-MG-BZ2
A
B
C
D
®
EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17
1-7
Chapter 1: Getting Started
6 1. Remove
Expansion
Connector
7 Protective
Cover from
rear of
8 panel.
13
14 Optional Accessories
A DC Power Adapter Serial Port w/ DC Power Adapter Clear Screen Overlay
EA-MG-P1 EA-MG-SP1 EA-MG-COV-CL
B
C
D
®
15 9
1
7
8
9
Expansion Pin Signal Pin Signal Pin Signal
10
Pin Signal Connector 1 Frame GND 6 LE 11 TXD+ (422/485)
1 Logic GND
2 TXD (232C) 7 CTS (232C) 12 TXD– (422/485)
2 not used
3 RXD (232C) 8 RTS (232C) 13 Term. Resistor
6 5 4 3 2 1 3 RXD (232C)
11
4 Supplies +5VDC 9 RXD+ (422/485) 14 do not use
4 TXD (232C)
5 Logic GND 10 RXD– (422/485) 15 do not use
5 Receives 5VDC
NOTE: Adapter requires 10.8-26.4 VDC supply.
6 Logic GND
Adapter mounts
RS-232
to back of panel
RS-232/422/485 12
NOTE: See Chapter 2: Specifications and Chapter 6: PLC Communications for additional details on the
13
available communication ports, protocols and cables.
14
NOTE: The panel has one built-in RJ12 serial communications port (Port1 - RS-232) and the option to add
one 15-pin serial communications port (Port2 - RS-232/422/485) to the panel by installing the EA-MG-SP1
module. Only one of the ports can be used with a connected PLC. The programming software allows the
A
user to select either Comm. Port1 or Comm. Port2 under the Panel Manager dialog box. When using Port
2 to communicate with the connected PLC, Port1 can still be used with the EA-MG-PGM-CBL Software B
Programming Cable Assembly to transfer projects between the PC and panel.
C
NOTE: If the DC power adapter is installed on the panel, the adapter must be powered.
D
®
EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17
1-9
Chapter 1: Getting Started
3 The screw torque range for the screws used on the panel mounting clips and the keypad bezel
mounting clips is 21-28 oz-in [0.15-0.2 Nm].
6 R0
.11
Units: inches [mm]
8[
R3 CUTOUT
7 +0.04
2.756 – 0.00
+1
70.0 –0
]
CUTOUT
OUTLINE
8 BEZEL
OUTLINE
9 0.236
[6.0] MOUNTING CLIP
(2) places
10 0.361
[9.2]
0.354
[9.0]
6.417 –+0.04
0.00
+1
163.0 –0
0.354
[9.0] EA-MG-BZ1 Keypad Bezel Cutout
11 R0
.09
8[
R2 CUTOUT
]
12 3.504 –+0.04
0.00
+1
89.0 –0
CUTOUT
OUTLINE
13 BEZEL
OUTLINE
14 0.361
[9.2]
PANEL CUTOUT
Units: inches [mm]
7.441 +0.04
– 0.00
189.0 +1
A
–0
0.361 0.354 0.354
[9.2] [9.0]
EA-MG-BZ2 Keypad Bezel Cutout
[9.0]
B R0
.09
8[
R2
]
CUTOUT
CUTOUT
3.504 +0.04 OUTLINE
C
– 0.00
89.0 +1
–0
NOTE: A minimum clearance of 1.2 inches
BEZEL
(30mm) must be maintained OUTLINE
10
your project before downloading it to connected panel.
the panel.
Make a New Project
Select Project
Location:
Project:
C:\My Documents\C-more Projects\ Browse...
MyProject
Enter a name
for your project
11
HMI Type: EA1-S3ML
13
14
A
B
C
D
®
EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17
1-11
Chapter 1: Getting Started
4
Cable Assembly
(Includes serial & USB cables)
p/n EA-MG-PGM-CBL
5
6 User PC
Serial
Cable
7 USB
Cable
8 USB to RS232
Converter
9 C-more
Micro-Graphic
Panel
10
11
12
13
14
A
B
C
D
®
7
1 = Sig GND (6P6C) TXD RXD (6P6C) 1 = Sig GND
2 = +5 VDC 3 4 2 = not used
RXD TXD
3 = RXD 3 = RXD
4 = TXD +5 V 2 5 +5 V 4 = TXD
5 = not used GND 1 6 GND 5 = +5 VDC
6 = Sig GND 6 = Sig GND
123456 123456
8
Panel Powered from a DC Power Adapter - Wiring Diagrams
DC Power Adapter
EA-MG-P1
Serial Port with
DC Power Adapter
9
EA-MG-SP1
NOTE: If either
DC power
adapter is
Port 2 10
installed on
the panel, the 11
adapter must be
Recommended
DC Supply Fuse
750 mA fast acting, Supply to adapter:
powered. Recommended
DC Supply Fuse
12
750 mA fast acting, Supply to adapter:
ADC p/n AGC-75 1 A @ 12 - 24 VDC
ADC p/n AGC-75
13
1 A @ 12 - 24 VDC
+ (10.8 - 26.4 VDC)
+ (10.8 - 26.4 VDC)
– –
GND
14
GND
Equipment Equipment
Ground Ground
NOTE: Recommended DC power supply to power either DC Power Adapter, AutomationDirect Part No.
PSC-24-015 or PSC-24-030.
A
Maximum
To PLC
Port Connector
Cable wiring example when power is supplied to panel from either a DC
Power Adapter, EA-MG-P1, or a Serial Port w/ DC Power Adapter, EA-MG-SP1
To C-more
Micro-Graphic
Serial Port 1
B
communication cable
length when powered
50 feet [15.0 m] Maximum
Wiring Diagram
RJ12 6-pin
Phone Plug
1 = Sig GND
C
1 (6P6C)
from an optional
GND GND 2 = do not use
DC Power Adapter
RXD
TXD
GND
3
4
6
RXD
TXD
GND
3 = RXD
4 = TXD
5 = +5 VDC
6 = Sig GND
D
123456
®
EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17
1-13
Chapter 1: Getting Started
1. Information 1. Memory
[pg. 5-6] [pg. 5-6]
9 Examples 2. Protocol
[pg. 5-6]
3. Extensions
10 [pg. 5-6]
4. Versions
[pg. 5-6]
11 SETUP MENU
1.Information >
2. Setting
[pg. 5-7 to 5-13]
1. LCD Contrast
[pg. 5-7]
12 3.Test Menu
4.Exit
BAK – UP DWN
>
ENT
[pg. 5-8 to 5-9]
3. Beep
[pg. 5-10]
13 F1 F2 F3 F4 F5 4. Calibration
[pg. 5-11]
14 [pg. 5-12]
A Total :
MEMORY
786432 Bytes
7. ourglass
[pg. 5-13]
Usage : 26206 Bytes
3. Test Menu 1. Serial Port1 – Loop Back Test
B
Free : 774166 Bytes
[pg. 5-14] [pg. 5-14 to 5-15]
Note If a Serial Port w/ DC
BAK -- -- -- -- Power apter E -M -SP1 2. PLC Enquiry Test
is installe then item 2 will [pg. 5-16]
be loop back test for Port 2
C
an items 2 3 4 will be shown
F1 F2 F3 F4 F5 as item 3 4 5. 3. Buzzer Test
[pg. 5-16]
D 4. Exit
[pg. 5-17]
[pg. 5-17]
®
EA1-MG-USER-M Hardware User Manual, 2nd Ed. Rev. D, 08/17
1-15
Chapter 1: Getting Started
3
Example of panel’s Port 1
4 connected to a CLICK PLC
5 C-more 3 Inch
Micro-Graphic Panel
CLICK PLC
6 Port 1
7
8
9 DV-1000CBL
serial cable
Port 2
10
11 Serial Port w/
DC Power Adapter
EA-MG-SP1
12
13 Example of panel’s optional Port 2
connected to a DL06 PLC
14 Port
Port
2
A DL06 PLC
B C-more to
Direct LOGIC C-more
VGA 15-pin port Micro Graphic
C serial cable
p/n EA-2CBL-1
Panel
D
®