You are on page 1of 2

AD00.19-N-9045GA Fault code list for central data memory (ZDS) control unit 11.1.

08
MODEL 930, 932, 933, 934

Fault code Fault code description


E101 Parameter checksum fault
E102 Control unit unlocking list faulty
E10B The chassis number parameterized in the base module is invalid.
E203 The latest data transfer has not been completed.
E204 One of the control units is not responding.
E205 One of the control units denies the unlocking command.
E206 One of the control units recognizes the message 'No safe condition'.
E207 Parameters could not be written to one of the control units.
E208 Parameters could not be read from one of the control units.
E220 The diagnostic channel to one of the control units is occupied.
E222 The affected control unit is not connected to the CAN bus.
E223 CAN communication is faulty.
E224 The diagnostic mode is not supported by the control unit.
E225 Implausible unlocking code
E226 The parameter set does not match the control unit.
E227 Protocol breach
E228 Invalid memory area
E229 Reading of the unlock date from the control unit has failed.
E231 Routine is not yet completed.
E233 Routine is not yet completed.
E234 Routine is not yet completed.
E237 Routine is not yet completed.
E238 Routine is not yet completed.
E23A Routine is not yet completed.
E23B Routine is not yet completed.
E309 The last interlock cancel date of one control unit does not match the corresponding date stored in control unit ZDS Central
data memory.
E30A The ID block of one of the control units is incorrect.
E30B The VIN of one of the control units is different from the VIN of control unit GM Base module.
E30C The data of the central data memory stored in the mirror memory of control unit INS Instrument are not up-to-date.
E30D The data of control unit GM Base module stored in the mirror memory of control unit INS Instrument are not up-to-date.
E30E There is no information stored in the central data memory for one of the control units installed.
E30F There is no information stored in the central data memory for one of the control units installed.
E310 The memory area of one control unit has a checksum error.
E31F The control unit address transmitted when the memory area was created is implausible.
E321 The selected function not parameterized in the central data memory.
E401 The central data memory data could not be written to the mirror memory.
E402 Unable to read data from mirror memory.
E403 No backup copy of data of control unit ZDS Central data memory found in mirror memory of control unit INS Instrument.
E404 The data of the external control units in the mirror memory are not up to date.
E405 The data stored in the central data memory and their backup copy stored in the mirror memory of control unit INS
Instrument are incompatible with one another.
E408 The data of the external control units in the mirror memory are more up to date.
E411 The data of control unit GM Base module could not be written to the mirror memory.
E412 The data of control unit GM Base module could not be read from the mirror memory.
E413 No backup copy of data of control unit GM Base module found in mirror memory of control unit INS Instrument.
E414 The data of the virtual control units in the mirror memory are not up to date.
E415 The data stored in control unit GM Base module are incompatible with the data stored in the mirror memory of control unit
INS Instrument.
E416 No memory area for base module or central data memory in mirror memory
E417 The data for the base module and (or) its virtual control units are not compatible with the data stored in the mirror memory.
E418 The data of the virtual control units in the mirror memory are more up to date.
E420 The diagnostic channel to the Instrument is busy.
E422 The Instrument is not connected to the CAN bus.
E423 The Instrument is not responding.
E424 The diagnostic mode is not supported by control unit INS Instrument.
E435 Unlocking of the Instrument has failed.
E436 The Instrument reports that the vehicle is not in a safe state.
E444 The date of the last data backup of the external control units cannot be read from the mirror memory.
E445 The date of the last data backup of the virtual control units cannot be read from the mirror memory.
E502 Fault when writing the EEPROM
E504 Plant mode active
E505 Memory in central data memory is full.

© Daimler AG, 10/25/11, G/09/11, ad00.19-n-9045ga, Fault code list for central data memory (ZDS) control unit Page 1 of 2
MODEL 930, 932, 933, 934
E510 Error when writing the flash memory
E604 One of the control units is not responding.
E608 Parameters could not be read from one of the control units.
E620 The diagnostic channel to the Instrument is busy.
E622 The affected control unit is not connected to the CAN bus.
E623 CAN communication is faulty.
E644 The date of the last data backup of the external control units cannot be read from the mirror memory.
E645 The date of the last data backup of the virtual control units cannot be read from the mirror memory.

© Daimler AG, 10/25/11, G/09/11, ad00.19-n-9045ga, Fault code list for central data memory (ZDS) control unit Page 2 of 2
MODEL 930, 932, 933, 934

You might also like