DETAILS OF CALIBRATION & DEMONSTRATION BLOCK FOR INSPECTION OF WC-06

Center Line

6 mm

6 mm
55º 10 mm
1

36+3 mm
33+3 mm

A 27mm
22 mm
2
3 B 18mm
4 5
70º C
9mm Flaw No. Location Length Height Width
4,5 OD surface 10 4 6 mm Max
15 mm
2,3 Subsurface 14 7 6 mm Max
1 ID Surface 10 7 6 mm Max
Note:-
Cap Edge
90mm 1) Dimensions are not to scale. Location of artificial defect in the weld may vary along the weld length;
Root Edge 100mm 2) But artificial defect length,height and width shall not more than indicated;
1 3) For depth of sub-surface flaws, please refer adjacent figure;
50mm 4) Weld configuration should match with that of the joint to be inspected
(A),(C)
A,B & C are Side Drilled Holes for PAUT & TOFD Calibration
2
Diameter of each SDH :3mm
Lenght of each SDH : 50mm
600 mm

50mm
3

50mm

50mm
(B)
5 100mm

600mm
DETAILS OFCALIBRATION & DEMONSTRATION BLOCK FOR INSPECTION OF WC-07/08/09/10

Center Line

6 mm

6 mm
55º 10 mm
1

36+3 mm
36 +3mm

25 mm
C
A
2
27mm
3
18mm
4
9mm 80º
B Flaw No. Location Length Height Width
4 OD surface 10 4 6 mm Max
2,3 Sub-surface 14 7.5 6 mm Max
1 ID Surface 10 7 6 mm Max
Cap Edge
NOTE:-
90 mm 1) Dimensions are not to scale. Location of artificial defect in the weld may vary along the weld length;
Root Edge 2) But artificial defect length,height and width shall not more than indicated;
1 3) For depth of sub-surface flaws, please refer adjacent figure
50mm 4) Weld configuration should match with that of the joint to be inspected
300mm

A,B & C are Side Drilled Holes for PAUT & TOFD Calibration
2
Diameter of each SDH :3mm
Lenght of each SDH : 50mm
600 mm

50mm
3
50mm (A),(B) (C)
50mm

600 mm
1) Dimensions are not to scale. Location of artificial defect in the weld may vary along the weld length;
DETAILS OF CALIBRATION & DEMONSTRATION BLOCK FOR INSPECTION OF WC-11

Center Line

6 mm

6 mm
D 55º 10 mm
1

50+3 mm
36+3 mm

A
E 27mm 25 mm 37.5mm
E 2 B
18mm 3
F 25mm
4 5 C
70º
9mm 12.5mm Flaw No. Location Length Height Width
4,5 OD surface 10 4 6 mm Max
50 mm
2,3 Subsurface 14 7.5 6 mm Max
1 ID Surface 10 7 6 mm Max
Note:-
Cap Edge
90mm 1) Dimensions are not to scale. Location of artificial defect in the weld may vary along the weld length;

100mm
100mm

Root Edge 2) But artificial defect length,height and width shall not more than indicated;
1 3) For depth of sub-surface flaws, please refer adjacent figure;
50mm 4) Weld configuration should match with that of the joint to be inspected
(D), (F) (A), (C)
A,B,C,D,E&F are Side Drilled Holes for PAUT & TOFD Calibration
2
Diameter of each SDH :3mm
Lenght of each SDH : 50mm
600 mm

50mm
3

50mm

4
(E)
50mm
100mm

5
100mm

(B)

600mm
DETAILS OF CALIBRATION & DEMONSTRATION BLOCK FOR INSPECTION OF WSC-01

Center Line

9 mm
1
A 16 mm

50 mm
50 mm

37.5mm 2
3 B
25mm
C 4
12.5mm
Flaw No. Location Length Height Width
4 OD surface 14 5 6 mm Max
2,3 Sub-surface 19 10 6 mm Max
1 ID Surface 14 8 6 mm Max
Note:-
Cap Edge
90 mm 1) Dimensions are not to scale. Location of artificial defect in the weld may vary along the weld length;
Root Edge 2) But artificial defect length,height and width shall not more than indicated;
1 3) For depth of sub-surface flaws, please refer adjacent figure
300mm 50mm 4) Weld configuration should match with that of the joint to be inspected

A,B & C are Side Drilled Holes for PAUT & TOFD Calibration
2
Diameter of each SDH :3mm
Lenght of each SDH : 50mm
600 mm

50mm
3

50mm (B)
(A),(C)
4

600 mm