You are on page 1of 76

ProxySG®

A
Quick Start Guide
R
D
TA

ProxySG 210
ProxySG 510
ProxySG 810
ProxySG 8100
BE

Document Number: 231-03029


Disclaimer
THIS DOCUMENT IS PROVIDED “AS IS” WITHOUT ANY EXPRESS OR IMPLIED WARRANTY OF ANY KIND, INCLUDING WARRANTIES OF MERCHANT-
ABILITY, NONINFRINGEMENT OF INTELLECTUAL PROPERTY, OR FITNESS FOR ANY PARTICULAR PURPOSE. IN NO EVENT SHALL BLUE COAT OR ITS
SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTER-
RUPTION, OR LOSS OF INFORMATION) ARISING OUT OF THE USE OF OR INABILITY TO USE THIS DOCUMENT, OR THE PRODUCTS DESCRIBED HEREIN,
EVEN IF BLUE COAT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME JURISDICTIONS PROHIBIT THE EXCLUSION OR
LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO YOU. Blue Coat and its
suppliers further do not warrant the accuracy or completeness of the information, text, graphics, links or other items contained within this
document, or assume liability for any incidental, indirect, special or consequential damages in connection with the furnishing, performance,
or use of this document. Blue Coat may make changes to this document, or to the products described herein, at any time without notice. Blue
Coat makes no commitment to update this document.

Copyright/Trademarks/Patents
Copyright© 1999-2009 Blue Coat Systems, Inc. All rights reserved worldwide. No part of this document may
be reproduced by any means nor modified, decompiled, disassembled, published or distributed, in whole or
in part, or translated to any electronic medium or other means without the written consent of Blue Coat
Systems, Inc. All right, title and interest in and to the Software and documentation are and shall remain the
exclusive property of Blue Coat Systems, Inc. and its licensors. BluePlanet™, BlueTouch™, Control Is
Yours™, DRTR™, ProxyAV™, ProxyRA Connector™, ProxyRA Manager™, SGOS™ and Webpulse™ and
the Blue Coat logo are trademarks of Blue Coat Systems, Inc. and Blue Coat®, BlueSource®, K9®,
IntelligenceCenter®, PacketShaper®, ProxyClient®, ProxySG®, Permeo®, and the Permeo logo are
registered trademarks of Blue Coat Systems, Inc. All other trademarks contained in this document and in the
Software are the property of their respective owners.
BLUE COAT SYSTEMS, INC. DISCLAIMS ALL WARRANTIES, CONDITIONS OR OTHER TERMS,
EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE, ON SOFTWARE AND DOCUMENTATION
FURNISHED HEREUNDER INCLUDING WITHOUT LIMITATION THE WARRANTIES OF DESIGN,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO
EVENT SHALL BLUE COAT SYSTEMS, INC., ITS SUPPLIERS OR ITS LICENSORS BE LIABLE FOR ANY
DAMAGES, WHETHER ARISING IN TORT, CONTRACT OR ANY OTHER LEGAL THEORY EVEN IF
BLUE COAT SYSTEMS, INC. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

Blue Coat Systems, Inc.


420 N. Mary Ave.
Sunnyvale, CA 94085
http://www.bluecoat.com

Revision History
March, 2009 231-03029 Rev A.0
Contents

About this Guide.............................................................................................................................................. 3


Navigation and Symbols........................................................................................................................ 3

Step 1: Preparing the ProxySG for Configuration......................................5


In this Section:............................................................................................................................................ 5
How to Deploy the ProxySG ........................................................................................................................ 6
Choosing a Configuration Workflow........................................................................................................ 7
Setup Checklist: In-Path Acceleration Solution .................................................................................... 8
Setup Checklist: All Other Deployments................................................................................................. 9
Configure Hardware Components..........................................................................................................10
Installing Hard Drives (510, 810, and 8100 models only).........................................................10
Installing Option Cards.........................................................................................................................12
Power-Off Traffic Verification....................................................................................................................13

Step 2: Configuring the ProxySG...............................................................15


In this Section...........................................................................................................................................15
Connecting to the Network.......................................................................................................................16
Configuring the ProxySG for In-Path Acceleration............................................................................17
Configuring the ProxySG for All Other Deployments ......................................................................19
Configuration Using the Serial Port .................................................................................................19
Configuration Using the Front Panel ..............................................................................................20

Step 3: Installing the ProxySG ...................................................................23


In this Section...........................................................................................................................................23
Installation Overview ...................................................................................................................................24
Rack-Mounting the ProxySG .....................................................................................................................25
Connecting the ProxySG to the Network and to Power..................................................................26

Step 4: Verifying a Successful Configuration ...........................................27


In this Section...........................................................................................................................................27
Licensing the ProxySG and Logging In..................................................................................................28
Register and License the ProxySG ....................................................................................................28
Log on to the ProxySG..........................................................................................................................28
Verifying In-Path Acceleration Deployments......................................................................................29
Verifying All Other ProxySG Deployments...........................................................................................30

ProxySG Quick Start Guide 1


Step 5: Where to Go Next ...........................................................................31

Appendix A: Product Information.............................................................33


ProxySG 210 ....................................................................................................................................................34
ProxySG 510 ....................................................................................................................................................36
ProxySG 810 ....................................................................................................................................................38
ProxySG 8100 ..................................................................................................................................................40
ProxySG Maintenance and Security.......................................................................................................43
Accessing the Command Line Interface (CLI) ..............................................................................43
Securing the Front Panel Keypad .....................................................................................................43
Restoring to Factory Defaults.............................................................................................................44
Support and Warranty .................................................................................................................................46
Regulatory Compliance...............................................................................................................................46
Declaration of Conformity..........................................................................................................................47
Proper Disposal of Electrical Equipment...............................................................................................48

Appendix B: Safety Notices........................................................................49


General Safety Information........................................................................................................................50
English: Server Safety Information ...................................................................................................50
Deutsch: Sicherheitshinweise für den Server...............................................................................54
Français: Consignes de sécurité sur le serveur.............................................................................58
Español: Información de seguridad del servidor ........................................................................62
Chinese: Server Safety Information..................................................................................................66
General System Cautions............................................................................................................................70
Warnings and Compliance Statements..........................................................................................70

2 ProxySG Quick Start Guide


About this Guide
The ProxySG Quick Start Guide describes how to install, connect, and configure a 
ProxySG appliance. Setup procedures are divided into five steps:

1 2 3 4 5
Prepare Verify
Install Where to Go Next
Information to Configure License and
Physically install Identify and
gather and steps Configuration register your
the ProxySG and access
to complete before steps for ADN and ProxySG, and
connect to your deployment
you configure your SWG deployments verify initial
network resources
ProxySG configuration

At the beginning of each step, a workflow diagram illustrates the path from start to 
finish. After you complete “Step 4: Verifying a Successful Configuration” on page 27, 
your ProxySG will ready for remote access. Additional deployment resources are listed 
in “Step 5: Where to Go Next” on page 31.

Navigation and Symbols


Running headers at the top of each page indicate your progress through the 
configuration progress. Within each workflow diagram, different shapes represent a 
process, document, or decision.
Document Navigation Symbols

1 Process
Prepare C I V N

Document
2
P Configure I V N
Decision

3 2
P C Install V N
Configure Current step

4
P C I Verify N
I Future step

5
P C I V Next P Completed step

ProxySG Quick Start Guide 3


4 ProxySG Quick Start Guide
Step 1: Preparing the ProxySG for Configuration

This workflow illustrates tasks to complete before you power‐on and configure your 
ProxySG appliance:

1
Prepare

Start

How to Deploy: In-path or


Configure
Overview and virtually in-
Hardware
Options path?
Virtually
in-path
In-path

Determine
deployment type Power-off traffic
and setup verification
workflow

Complete the
Setup Checklist Continue with
Check cabling No Traffic verified? Yes
Step 2: Configure

In this Section:
• “How to Deploy the ProxySG” on page 6
• “Choosing a Setup Workflow” on page 7
• “Setup Checklist: In‐Path Acceleration Solution” on page 8
• “Setup Checklist: All Other Deployments” on page 9
• “Configure Hardware Components” on page 10
• “Power‐Off Traffic Verification” on page 13

ProxySG Quick Start Guide 5


1
Prepare C I V N

How to Deploy the ProxySG


ProxySG appliances comprise an integral part of your enterprise’s Application Delivery 
Network (ADN) and provide acceleration, optimization, and caching features that 
optimize and secure the flow of information to any user. Your ProxySG can also function 
as a Secure Web Gateway (SWG) that protects your network from malware and 
spyware, prevents data leakage, and ensures user compliance with corporate 
networking guidelines.
Configuration steps vary by the licensed software edition for the ProxySG (Proxy or 
MACH5), and whether you deploy the appliance in‐path or virtually in‐path.

Software Editions Your ProxySG appliance ships with a software license for one of two 


editions:
• Proxy: a software edition that includes both SWG and ADN features
• MACH5: a software edition streamlined for ADN (acceleration) deployments

Typical Topologies ProxySG appliances are commonly deployed directly in the data 


path or virtually in‐path where a switch or router redirects data to the ProxySG.
• In‐path: the ProxySG is physically inserted into the path of the clients and 
servers—all traffic must pass through the appliance
• Virtually in‐path: the ProxySG appliance is not in the physical path of clients and 
servers, but relies on an external device (for example, a switch or router that 
supports WCCP) to redirect traffic to the ProxySG

ProxySG Deployed In-Path


Local computer Switch ProxySG Router

WAN

ProxySG Deployed Virtually In-Path (WCCP)


Local computer Switch Router

WAN

WCCP

ProxySG

Next: “Choosing a Setup Workflow” on page 7

6 ProxySG Quick Start Guide


1
Prepare C I V N

Choosing a Setup Workflow


Depending on your deployment, one of two setup scripts will prompt you for 
information about the appliance and your network. Use the workflow below to 
determine which setup script applies to you, and then complete the designated setup 
checklist.

ProxySG
deployed No
in-path?

Yes

Acceleration
No
solution?

Yes

Manual
configuration
No
(not using
Director)

Yes

Configure via
No
serial console?

Yes

SGOS 5.4.x or
No
higher?

Yes

“Setup Checklist: In-Path “Setup Checklist: All Other


Acceleration Solution” on Deployments” on page 9
page 8

ProxySG Quick Start Guide 7


1
Prepare C I V N

Setup Checklist: In-Path Acceleration Solution


Where applicable, brackets indicate [default] values.
 Note: This checklist applies only to ProxySG appliances running SGOS 5.4.x and higher. If
version 5.3.x or lower is pre-installed on your appliance, complete the “Setup Checklist:
All Other Deployments” on page 9. To verify the installed software version, refer to the
packing slip that accompanied your ProxySG.

Description Value

ProxySG Name [ProxySG Model and serial number]

ProxySG IP Address

Subnet Mask

Default Gateway

(optional) VLAN ID

Using Director?
If so, what is the Director’s IP address?

Primary DNS Server

Link Settings (speed and duplex) [auto detect]

Administrator ID and password

Will you activate acceleration immediately? [yes] turns on acceleration features for default protocols between
this ProxySG and other ProxySG appliances on your network

Next: “Configure Hardware Components” on page 10

8 ProxySG Quick Start Guide


1
Prepare C I V N

Setup Checklist: All Other Deployments

Description Value

ProxySG Name [ProxySG Model and serial number]

Is the ProxySG appliance’s IP address on a VLAN interface [no]


with an ID other than 1? If so, what is the VLAN ID number?

ProxySG IP Address

Subnet Mask

Default Gateway

Using Director? If so, what is the Director’s IP address?

Primary DNS Server

Link Settings [auto detect speed and duplex settings]

Console user name and password [admin] [ ]

Enable password The password to enable administrative credentials for the CLI
and Management Console interfaces

Will you secure the serial port with a password? [yes]


Serial port password

Will you restrict the console account to a specific [yes]


workstation’s IP address?
Authorized workstation’s IP address [0.0.0.0]

Software license edition [Proxy] (SWG) or MACH5 (acceleration)

In-path or virtually in-path (WCCP)? [in-path]

Next: “Configure Hardware Components” on page 10

ProxySG Quick Start Guide 9


1
Prepare C I V N

Configuring Hardware Components


ProxySG models range in size from compact desktop models to high‐capacity 
appliances with multiple hard drives and option cards. In addition, most models ship 
with rack‐mount hardware. Before rack‐mounting your appliance, install any additional 
hardware components such as option cards.
• “Installing Hard Drives (510, 810, and 8100 models only)” on page 10
• “Installing Option Cards” on page 12
• “Power‐Off Traffic Verification” on page 13

Installing Hard Drives (510, 810, and 8100 models only)


Hard drives for ProxySG models 510, 810, and 8100 ship in a separate package. To install 
drives in these ProxySG models:
1. Unpack your appliance and place it with the front bezel overhanging the front of a 
sturdy work surface. Push in the tabs on either side and fold the front bezel down.

2. Unpack the hard drive(s).

10 ProxySG Quick Start Guide


1
Prepare C I V N

3. Install each drive into the ProxySG chassis:

ProxySG 510 and 810


1 3

1 Press the drive release button and


swing open the locking lever.

2 Install drives from left to right. With


the locking lever open, slide the drive
into the chassis until fully seated.

2 3 Close the locking lever.

ProxySG 8100

1 Open the locking lever.


1

4
0
1
0
1
2 3 4 5
2 With the locking lever open,
6 7 8

install drives from left to right,


5

6 MENU

alternating between slots 1-4


2
and 5-8. Slide the drive into the
3 chassis until fully seated.

3 Close the locking lever.

4. Close the front bezel.
! Important: To prevent damage to the drive bays and back plane, always remove all drives
before moving or shipping ProxySG models 510, 810, and 8100.

ProxySG Quick Start Guide 11


1
Prepare C I V N

Installing Option Cards


Some ProxySG models support additional Network Interface Cards (NICs) and SSL 
Offload Cards. If the option card is not pre‐installed, refer to its installation instructions 
and install the card now.

Next: • In‐path deployments: “Power‐Off Traffic Verification” on page 13
• Virtually in‐path deployments: “Step 2: Configuring the ProxySG” on page 
15

12 ProxySG Quick Start Guide


1
Prepare C I V N

Power-Off Traffic Verification


If your ProxySG appliance will be installed in the data path, verify that network traffic 
passes through the appliance when it is powered off.
1. Connect the ProxySG to your network (but do not connect the power cord). If you 
are installing in‐path, network traffic will be interrupted as you insert the appliance 
into the data path.

In-Path Connection
To WAN (Router)

1:0
WAN 2:

1:1
LAN
0:0

To LAN (Switch)

2. From a local computer on the near side of the ProxySG, issue a ping request to a 
remote computer on the far side:
ping <remote_IP>

where remote_IP is the IP address of the remote computer.

Remote computer

Local computer ProxySG

ping origin ping response

No ping response Check the following and re‐try the ping request:


• Re‐try the ping to a different remote computer.
• Verify the remote computer’s DNS name or IP address.
• Connect the ProxySG to a different port on the switch or router.
• Replace the network cables and ensure that they are plugged in securely.

Successful ping response Go to “Step 2: Configuring the ProxySG” on page 15

ProxySG Quick Start Guide 13


1
Prepare C I V N

14 ProxySG Quick Start Guide


Step 2: Configuring the ProxySG

This workflow illustrates tasks to configure your ProxySG appliance:

2
Configure

Configure using
Connect to the All Serial port or Front
the front panel
network Other front panel? Panel
keypad

Serial Port

Verify network Check


Configure using
connectivity with configuration
In-Path Acceleration the serial console
power on settings

Configure using Continue with


Yes Traffic verified? No
the serial console Step 3: Install

In this Section
• “Connecting to the Network” on page 16
• “Configuring the ProxySG for In‐Path Acceleration” on page 17
• “Configuring the ProxySG for All Other Deployments” on page 19

ProxySG Quick Start Guide 15


2
P Configure I V N

Connecting to the Network


 Note: If this ProxySG appliance will be deployed in a remote location or if the network is
not currently accessible, you can skip this optional step .

You can either connect the ProxySG appliance to the network now, or after the appliance 
is configured and physically installed (“Rack‐Mounting the ProxySG” on page 25). 
Consider connecting to the network now if:
• You can configure the appliance in‐place (that is, connected to the network at its 
deployment location)
• You wish to verify server addresses and link settings during the configuration 
process (automatic when configuring through the serial port)
The following diagram illustrates typical network connections for in‐path and virtually 
in‐path (WCCP) deployments:

In-Path Connection
To WAN (Router)

1:0
WAN 2:

1:1
LAN
0:0

To LAN (Switch)

Virtually In-Path Connection

1:0
WAN 2:

1:1
LAN
0:0

To WCCP-Enabled Router

Next: • If you completed “Setup Checklist: In‐Path Acceleration Solution” on page 
8, continue with “Configuring the ProxySG for In‐Path Acceleration” on 
page 17
• If you completed “Setup Checklist: All Other Deployments” on page 9, 
continue with “Configuring the ProxySG for All Other Deployments” on 
page 19

16 ProxySG Quick Start Guide


2
P Configure I V N

Configuring the ProxySG for In-Path Acceleration


 Note: This procedure applies to those who completed “Setup Checklist: In-Path
Acceleration Solution” on page 8.

This procedure describes how to quickly configure the ProxySG for in‐path acceleration 
only, and sets Sky Management Console as the default interface. The final step of the 
configuration wizard gives you the option to activate acceleration immediately.
• Choose Yes to accelerate default services between this appliance and other 
ProxySG appliances on your network
• Choose No if you wish to manage acceleration for each individual service. The 
ProxySG will operate in bypass mode and not accelerate any traffic. You can then 
observe the types of traffic on your network, decide which services to accelerate, 
and assess the effects of acceleration on a per‐application basis.
1. Connect a null modem (serial) cable between a computer or terminal and the serial 
port on the ProxySG.
2. Connect the ProxySG to power and toggle the power switch (on models without 
power switches, the appliance will power on immediately).
3. Configure the terminal or terminal emulation software (such as HyperTerminal):
■ Baud rate: 9600 bps
■ Parity: None
■ Flow control: None
■ Data bits: 8
■ Stop bits: 1
4. Press <Enter> three times to activate the serial console and display the installed 
version of SGOS software:
■ Version 5.4.x and higher: continue with the next step
■ Version 5.3.x and lower: select Setup Console and refer to “Setup Checklist: All 
Other Deployments” on page 9 to enter information as prompted. When 
finished, continue with “Step 3: Installing the ProxySG” on page 23.
5. From the SG Appliance Serial Console menu, select Setup Console to launch the 
configuration wizard.
6. Refer to “Setup Checklist: In‐Path Acceleration Solution” on page 8 and enter 
information as prompted. If your ProxySG is connected to the network, the 
configuration wizard will attempt to verify server addresses and auto‐detect link 
settings. If it is not connected to the network, you will be prompted for link speed 
and duplex settings.
e Tip: To display help for a setup step, type ?.

ProxySG Quick Start Guide 17


2
P Configure I V N

7. Once you answer all questions, a summary screen lets you review all settings and 
make any needed corrections:
You have provided the following information for this device:

1: This device is manually configured.


2: You will implement the acceleration solution on this device.
3: You will deploy this device physically in-path.
4: Appliance name: Proxy SG 210 - Serial # 1234567890
5: You have configured the following hardware bridge interface:
Speed
Interface IP address Subnet mask (Mbps) Duplex Type
----------------------------------------------------------------------------
0:0-0:1 10.23.45.67 255.255.255.0 100 Full Configured
----------------------------------------------------------------------------
6: Default gateway: 10.2.34.5
7: DNS: 10.2.2.100
8: Administrator ID: admin
9: Administrator password: ********
10: You would like to activate acceleration immediately

To change a setting, enter the corresponding step number.


To save your settings, input [Save] and press ENTER:

8. When finished, press <Enter> to commit your settings.

Next: “Step 3: Installing the ProxySG” on page 23

18 ProxySG Quick Start Guide


2
P Configure I V N

Configuring the ProxySG for All Other Deployments


 Note: This procedure applies to those who completed “Setup Checklist: All Other
Deployments” on page 9.

The following procedures explain how to configure the ProxySG for any type of 
deployment, and set the Management Console as the default interface:
• “Configuration Using the Serial Port” on page 19
• “Configuration Using the Front Panel” on page 20

Configuration Using the Serial Port


To configure the ProxySG using the serial port, do the following:
1. Connect a null modem (serial) cable between a computer or terminal and the serial 
port on the ProxySG.
2. Connect the ProxySG to power and toggle the power switch (on models without 
power switches, the appliance will power on immediately).
3. Configure the terminal or terminal emulation software (such as HyperTerminal):
■ Baud rate: 9600 bps
■ Parity: None
■ Flow control: None
■ Data bits: 8
■ Stop bits: 1
4. Press <Enter> three times to activate the serial console.
5. From the SG Appliance Serial Console menu, select Setup Console to launch the 
configuration wizard.
6. Choose a configuration method:
■ Manual Setup: choose this method unless you are registering this ProxySG 
with a Director (Blue Coat’s central management solution).
■ Register with Director: choose this method to register this ProxySG with 
Director. You will need the Director’s IP address and registration password.
7. Refer to “Setup Checklist: All Other Deployments” on page 9 and enter information 
as prompted. If your ProxySG is connected to the network, the configuration wizard 
will attempt to verify server addresses and auto‐detect link settings. If it is not 
connected to the network, you will be prompted for link speed and duplex settings.

Next: “Step 3: Installing the ProxySG” on page 23

ProxySG Quick Start Guide 19


2
P Configure I V N

Configuration Using the Front Panel


On some ProxySG models, you can configure the appliance using a front panel keypad 
and LCD screen.

Front Panel Keypad and LCD Screen

Up, Down, Left, and Right Arrows

LCD

1 2 0 1

MENU Menu

Enter

To configure the ProxySG using the front panel:
1. Connect the ProxySG to power and toggle the power switch (on models without 
power switches, the appliance will power on immediately).
2. When the boot cycle finishes, the LCD displays IP address not configured. Press any 
button to display configuration options and enter Configure mode (the LCD 
displays Setup Mode? Manual).
3. Press the Down button to display the IP address.
4. Press the Enter button to enter Edit mode (cursor changes to a blinking box).
5. Using the Right and Left buttons, position the cursor over the characters and press 
the Up or Down buttons to change them.
6. When finished, press the Enter button to save changes and return to Configure 
mode.
7. Repeat steps 4 through 6 to specify the Subnet mask, Gateway address, DNS 
address, console password, and enable password.
8. When the LCD reads Console password: Push to set, press the Enter button to 
display an auto‐generated password. Either write down this password (you can 
change it later in the Management Console), or press the Enter button again to 
change it now. You will need this password to log on to the appliance.
9. Optional: Secure the serial console port with a password.

20 ProxySG Quick Start Guide


2
P Configure I V N

! Caution: If you lose the serial console password, you must restore the appliance to its
original factory defaults to regain serial console access.

10. When prompted, select the software edition (Proxy or MACH5) licensed for this 
ProxySG.
11. Press the Menu button to exit Configuration mode.
12. In‐path deployments only: to verify that network traffic will pass through the 
appliance when it is powered on and configured, from a local computer on the near 
side of the ProxySG, issue a ping request to a remote computer on the far side:
ping <remote_IP>

where remote_IP is the IP address of the remote computer.

Remote computer

Local computer ProxySG

ping origin ping response

No ping response Check the following and re‐try the ping request:


• Verify the ProxySG appliance’s IP address, subnet mask, gateway address, and 
DNS server address and repeat the configuration steps.
• Verify the remote computer’s DNS name or IP address.
• Re‐try the ping to a different remote computer.
• Connect the ProxySG to a different port on the switch or router.
• Replace the network cables and ensure that they are plugged in securely.

Successful ping response Go to “Step 3: Installing the ProxySG” on page 23.

ProxySG Quick Start Guide 21


2
P Configure I V N

22 ProxySG Quick Start Guide


Step 3: Installing the ProxySG

This workflow illustrates tasks to physically install your ProxySG appliance:

3
Install

Rack or shelf
Power off the
Remove all cabling mount the
ProxySG
ProxySG

Connect the
ProxySG to the Power on the Continue with
network and to ProxySG Step 4: Verify
power

In this Section
• “Installation Overview” on page 24
• “Rack‐Mounting the ProxySG” on page 25
• “Connecting the ProxySG to the Network and to Power” on page 26

ProxySG Quick Start Guide 23


3
P C Install V N

Installation Overview
All ProxySG models can be installed in standard 19‐inch racks or secured to a sturdy 
shelf or table‐top. The following table lists rack‐mounting options for each ProxySG 
model:

ProxySG Model Rack-Mounting Options

ProxySG 210 Side rack-mounting kit included

ProxySG 510 1U rack-mounting brackets pre-installed

ProxySG 810 1U rack-mounting brackets pre-installed

ProxySG 8100 4U rack-mounting brackets pre-installed, slide rails available

Refer to “Appendix A: Product Information” on page 33 for the power and 
environmental specifications of your ProxySG appliance, and to “Appendix B: Safety 
Notices” on page 49 for safety and environmental warnings.

24 ProxySG Quick Start Guide


3
P C Install V N

Rack-Mounting the ProxySG


To mount your ProxySG appliance to a four‐post rack using slide rails, refer to the 
instructions that accompany the slide rail kit. To mount your ProxySG in a standard, 
two‐post 19‐inch equipment rack:
1. Power off the appliance and disconnect all cables.
2. Find a location on the rack with space to mount the ProxySG, adequate power, and 
proximity to a router or switch on the network.
3. Secure the appliance with equipment‐rack screws:

ProxySG Quick Start Guide 25


3
P C Install V N

Connecting the ProxySG to the Network and to Power


1. Connect the appliance to the network (see “Connecting to the Network” on page 
16).
2. Connect the appliance to power. If configured with dual power supplies, connect 
each power supply to a separate circuit.

Next: “Step 4: Verifying a Successful Configuration” on page 27

26 ProxySG Quick Start Guide


Step 4: Verifying a Successful Configuration

This workflow illustrates tasks to verify the successful configuration of the ProxySG 
appliance:

4
Verify

License and
Verify ProxySG Continue with
register the
status Where to Go Next
ProxySG

In this Section
• “Licensing the ProxySG and Logging In” on page 28
• “Verifying In‐Path Acceleration Deployments” on page 29
• “Verifying All Other ProxySG Deployments” on page 30

ProxySG Quick Start Guide 27


4
P C I Verify N

Licensing the ProxySG and Logging In


Now that your ProxySG appliance is configured and connected to the network, install 
licenses, register the appliance, and verify its operating status. To activate the license, 
you must log in to BlueTouch Online, Blue Coat’s customer service portal, to register the 
appliance and download a license. 
e Tip: Your ProxySG ships with a temporary (60-day) license. You can register your
appliance at any time during that period.

Register and License the ProxySG


To register and license your ProxySG now, open a Web browser and navigate to:
■ https://hypersonic.bluecoat.com/
(customers with an existing BlueTouch Online or WebPower account), or
■ http://www.bluecoat.com/support/customercare (new customers)

Follow the instructions to register your appliance and download a license. 

Log on to the ProxySG


Log on to your ProxySG using a Web browser (refer to the SGOS release notes for a list 
of supported browsers):
1. Open a Web browser.
2. Disable the browser’s pop‐up blocker or configure it to allow pop‐ups from the 
ProxySG appliance’s IP address.
3. Log on using https by entering any of the IP addresses assigned to the appliance, 
followed by port number 8082. For example:
https://10.25.36.47:8082
4. Enter the user name and password you specified during configuration to access the 
user interface:
■ Sky Management Console: Introduced in SGOS 5.4, Sky Management Console 
provides a customized user interface for in‐path acceleration deployments.
■ Management Console: The interface for all other ProxySG deployments.

Next: ■ “Verifying In‐Path Acceleration Deployments” on page 29, or
■ “Verifying All Other ProxySG Deployments” on page 30

28 ProxySG Quick Start Guide


4
P C I Verify N

Verifying In-Path Acceleration Deployments


If you configured your ProxySG for an in‐path acceleration deployment, Sky 
Management Console is the default user interface. The Monitor tab serves as the home 
page of Sky Management Console, and displays panes for Device Status, Bandwidth 
Usage, and Optimized Throughput:

Banner and Navigation Tabs

Bandwidth
Device Status Optimized Throughput
Usage

To verify your ProxySG deployment:
1. In the Device Status pane:
a. Check the Alerts section for warnings and error messages. For details or to take 
action, click the message.
b. If you chose to activate acceleration immediately during configuration, check 
the Acceleration Status section to verify that acceleration is enabled and the 
identity of peer ProxySG appliances. Click a setting to change it.
c. In the Deployment Status section, verify the speed, duplex, and link settings for 
each interface. Click a setting to make a correction.
2. In the Bandwidth Usage pane, verify that traffic passes through the ProxySG. If 
acceleration is active, the displayed graphs show both actual and effective 
throughput for the top bandwidth protocols.
3. In the Optimized Throughput pane, review the benefits of acceleration (if active).
e Tip: To access the Management Console, go to the Configure tab and click the Advanced
Configuration button.

Next: “Step 5: Where to Go Next” on page 31

ProxySG Quick Start Guide 29


4
P C I Verify N

Verifying All Other ProxySG Deployments


If you configured your ProxySG for any deployment other than in‐path acceleration, the 
Management Console opens and displays the Statistics Summary tab:

Banner and Navigation Tabs

Navigation
Data
Links

To verify your ProxySG deployment:
1. In the Interface Utilization section of the Data pane, verify the Link State for each 
configured interface.
2. Review information in the Banner:
a. ProxySG identification: the appliance name, model, serial number, and software 
version.
b. ProxySG health status: the health state is represented by color‐coded text 
(where green is OK, yellow is Warning, and red is Critical). To see the system’s 
health monitoring metrics, click the link to display the Statistics > Health 
Monitoring page.
c. License status and version: to view a list of the license components and their 
expiration date, go to the Maintenance > Licensing > View tab. If not yet 
licensed, the 60‐day trial license is enabled.
3. In the Navigation Links pane, go to Statistics > Device and verify connectivity with 
the DNS server.

Next: “Step 5: Where to Go Next” on page 31

30 ProxySG Quick Start Guide


Step 5: Where to Go Next

The following table lists additional resources to help you maximize the value of your 
ProxySG deployment.

Interest Recommended Resource

Context-sensitive information about Online Help. To access, click the Help button in the Sky Management
ProxySG features Console or Management Console interfaces.

How to get started with the ProxySG Getting Started Guide, available at:
https://hypersonic.bluecoat.com/documentation/

Reference documentation Configuration and Management Guide (CMG), a collection of volumes


documenting ProxySG features. To access, click the Documentation link in
the Sky Management Console or Management Console interfaces, or visit:
https://hypersonic.bluecoat.com/documentation/

Virtually In-Path deployments WCCP Reference Guide, available at:


https://hypersonic.bluecoat.com/documentation/

Application Delivery Network (acceleration) ADN Deployment Guide, available at:


deployments https://hypersonic.bluecoat.com/documentation/

Technical support or hardware maintenance Blue Coat Support, available online at:
http://www.bluecoat.com/support/overview

Contact Blue Coat by telephone toll free in North America at


(866) 982-2628, or directly at +1 (408) 220-2299.

Deployment planning, consulting, and Blue Coat Professional services, available at:
customization http://www.bluecoat.com/support/professionalservices

Classroom and Web-based training Blue Coat Training, available at:


http://www.bluecoat.com/support/training

Answers to frequently-asked questions Blue Coat Knowledgebase, available at:


https://hypersonic.bluecoat.com/support/kb/proxy

Blue Coat user community Blue Coat Support Forums, available at:
http://forums.bluecoat.com/

ProxySG Quick Start Guide 31


5
P C I V Next

32 ProxySG Quick Start Guide


Appendix A: Product Information

The following sections contain product information for ProxySG appliances:
• “ProxySG 210” on page 34
• “ProxySG 510” on page 36
• “ProxySG 810” on page 38
• “ProxySG 8100” on page 40

Additional product information:
• “ProxySG Maintenance and Security” on page 43
• “Support and Warranty” on page 46
• “Regulatory Compliance” on page 46
• “Declaration of Conformity” on page 47
• “Proper Disposal of Electrical Equipment” on page 48

ProxySG Quick Start Guide 33


Appendix A: Product Information

ProxySG 210
In this section:
• “ProxySG 210 Specifications” on page 34
• “ProxySG 210 LEDs” on page 35

ProxySG 210 Specifications


Specifications and configurations are subject to change without notice. For current 
specifications, see: http://www.bluecoat.com/products/sg/210/specifications. 

Specification SG210-5 SG210-10 SG210-25

Dimensions and Weight


Enclosure Desk/wall mount, rack mountable
Dimensions (L x W x H) 35.6cm x 19.1cm x 4.4cm (14in x 7.5in x 1.72in)
Weight (maximum) 2.6kg (5.8lb), +/- 5%

Mounting Options
Rack mounting Side rack-mounting kit included
Operating angle Rack and bench: 0°
Wall: 90° (wall mounting hardware not included)

Operating Environment
Power AC power 100-240V, 50-60Hz, 6.3-3.0A
Maximum Power 45 watts
Thermal Rating 153.63 BTU/Hr
Temperature 5°C to 35°C (41°F to 95°F)
Humidity Less than 90% relative humidity, non-condensing
Altitude Operating: Up to 3048 M (10,000 ft)

System
Disk drives 1x80GB IDE 137GB IDE accessible (250GB IDE model)
RAM 512 MB 1 GB
Network Interfaces (2) integrated (on (2) integrated (on board) 10/100Base-T NICs with
board) 10/100Base-T passthrough SSL Offload card
Optional NICs/Cards NICs with passthrough None
SSL Offload card

34 ProxySG Quick Start Guide


Appendix A: Product Information

ProxySG 210 LEDs


ProxySG 210 appliances feature front‐panel LEDs that indicate power, disk activity, 
interface activity, and system status, and LEDs on each back‐panel network interface 
that indicate link status and speed:

210 Front Panel LEDs Network Inferface LEDs

Power Disk Interfaces System


Speed Activity

Front Panel LEDs Network Interface LEDs

Power Speed
Off: Powered off or non functional Off: 10 Mbps
Amber: Loading OS Green: 100 Mbps
Amber/Green: Unconfigured Amber: 1000 Mbps
Green: Powered on and configured

Disk Activity
Off: No activity Off: No link
Green flicker: hard disk and/or compact flash activity Green solid: Linked
Green flicker: Link activity
Interface
Off: No Link
Amber/Green: Network activity
Green: Linked

System
Off: No status
Green: Healthy
Amber: Warning
Red: Critical Warning
Blue: Diagnostic mode

ProxySG Quick Start Guide 35


Appendix A: Product Information

ProxySG 510
In this section:
• “ProxySG 510 Specifications” on page 36
• “ProxySG 510 LEDs” on page 37

ProxySG 510 Specifications


Specifications and configurations are subject to change without notice. For current 
specifications, see: http://www.bluecoat.com/products/sg/510/specifications. 

Specification SG510-5 SG510-10 SG510-20 SG510-30

Dimensions and Weight


Enclosure 1U, rack mountable
Dimensions (L x W x H) 580mm x 440mm x 44mm (22.8” x 17.4” x 1.7”)
Weight (maximum) 12.7kg (28 lbs) maximum, +/- 5% (excluding rack mount kit)

Mounting Options Rack-mount kit included

Operating Environment
Power AC power 100-240V, 50-60Hz, 6.3-3.0A
Maximum Power 150 watts
Thermal Rating 512 BTU/Hr
Temperature Operating: 5°C to 35°C (41°F to 95°F)
Humidity Less than 90% relative humidity, non-condensing
Altitude Up to 3048 M (10,000 ft)

System
Disk drives 2 x 80GB SATA 2 x 320 GB SATA 2 x 320 GB SATA 2 x 320 GB SATA
RAM 2 GB 2 GB 2 GB 2 GB
SSL Offload Card Optional Standard Standard Standard

Network
Network Interfaces (1) integrated 10/100/1000 Base-T NICs with passthrough
Expansion Slots (1) PCI Express
Optional NICs/Cards ● Copper: (2) x 1000Base-T
● Copper: (4) x 10GBase-T
● Fiber: (2) x 1 000Base-SX

36 ProxySG Quick Start Guide


Appendix A: Product Information

ProxySG 510 LEDs


ProxySG 510 appliances feature front‐panel LEDs that indicate power, disk activity, and 
interface activity, and LEDs on each back‐panel network interface that indicate link 
status and speed:
510 Front Panel LEDs Network Interface LEDs

1 Speed Activity
2 0 1

Power Hard Disk Interfaces

Front Panel LEDs Network Interface LEDs

Power Speed
Off: Powered off or non functional Off: 10 Mbps
Amber: Loading OS Green: 100 Mbps
Amber/Green: Unconfigured Amber: 1000 Mbps
Green: Powered on and configured

Hard Disk Activity


Off: No activity Off: No link
Green flicker: hard disk and/or compact flash activity Green solid: Linked
Green flicker: Link activity
Interfaces
Off: No Link
Amber/Green: Network activity
Green: Linked

ProxySG Quick Start Guide 37


Appendix A: Product Information

ProxySG 810
In this section:
• “ProxySG 810 Specifications” on page 38
• “ProxySG 810 LEDs” on page 39

ProxySG 810 Specifications


Specifications and configurations are subject to change without notice. For current 
specifications, see: http://www.bluecoat.com/products/sg/810/specifications. 

Specification SG810-5 SG810-10 SG810-20 SG810-30

Dimensions and Weight


Enclosure 1U, rack mountable
Dimensions (L x W x H) 580mm x 440mm x 44mm (22.8” x 17.4” x 1.7”)
Weight 14.1kg (31 lbs) to 15.4 kg (34 lbs), +/- 5% (excluding rack mount kit)

Mounting Options Rack-mount kit included

Operating Environment
Power AC power 100-240V, 50-60Hz, 6.3-3.0A
Maximum Power 375 watts
Thermal Rating 1280.25 BTU/Hr
Temperature Operating: 5°C to 35°C (41°F to 95°F)
Humidity Less than 90% relative humidity, non-condensing
Altitude Up to 3048 M (10,000 ft)

System
Disk drives (SCSI Ultra 320) 2 x 73GB 2 x 300 GB 4 x 300 GB 4 x 300 GB
RAM 2 GB 4 GB 6 GB 6 GB
SSL Offload Card Optional Standard Standard Standard

Network
Network Interfaces Integrated: 2 on-board 10/100/1000 Base-T NICs with passthrough
Card: 2 x 10/100/1000 Base-T NICs with passthrough (except 810-5)
Expansion Slots 1 PCI Express
Optional NICs/Cards ● Copper: (2) x 1000Base-T
● Copper: (4) x 10GBase-T
● Fiber: (2) x 1 000Base-SX

38 ProxySG Quick Start Guide


Appendix A: Product Information

ProxySG 810 LEDs


ProxySG 810 appliances feature front‐panel LEDs that indicate power and disk activity, 
and LEDs on each back‐panel network interface that indicate link status and speed:
810 Front Panel LEDs Network Interface LEDs

Speed Activity
1 2 3 4

Power Hard Disk

Front Panel LEDs Network Interface LEDs

Power Speed
Off: Powered off or non functional Off: 10 Mbps
Amber: Loading OS Green: 100 Mbps
Amber/Green: Unconfigured Amber: 1000 Mbps
Green: Powered on and configured

Hard Disk Activity


Off: No activity Off: No link
Green flicker: hard disk and/or compact flash activity Green solid: Linked
Green flicker: Link activity

ProxySG Quick Start Guide 39


Appendix A: Product Information

ProxySG 8100
In this section:
• “ProxySG 8100 Specifications” on page 40
• “ProxySG 8100 LEDs” on page 41

ProxySG 8100 Specifications


Specifications and configurations are subject to change without notice. For current 
specifications, see: http://www.bluecoat.com/products/sg/8100/specifications. 

Specification SG8100-5 SG8100-10 SG8100-20 SG8100-30

Dimensions and Weight


Enclosure 4U, rack mountable
Dimensions (L x W x H) 592mm x 442mm x 176mm (22.8” x 17.4” x 1.7”)
Weight 25.4 kg (56 lbs) to 30.8 kg (68 lbs), +/- 5% (excluding rack mount kit)

Mounting Options Rack-mount kit included

Operating Environment
Power AC power 100-240V, 50-60Hz, 6.3-3.0A
Maximum Power 525 watts
Thermal Rating 1792 BTU/Hr
Temperature Operating: 5°C to 40°C (41°F to 104°F)
Humidity Less than 90% relative humidity, non-condensing
Altitude Up to 3048 M (10,000 ft)
DC Adapter Voltage 36-72 volts DC steady state current: 28 amp (typical)
Inrush current: less than 10 amps (per module)

System
Disk drives (SCSI Ultra 320) 2 x 320GB 4 x 320 GB 8 x 320 GB 8 x 320 GB
RAM 4 GB 6 GB 8 GB 16 GB
SSL Offload Card Optional Standard Standard Standard

Network
Network Interfaces Integrated: 2 on-board 10/100/1000 Base-T NICs with passthrough
Card: 4 x 10/100/1000 Base-T NICs with passthrough (except 8100-5)
Expansion Slots 2 PCI Express
Optional NICs/Cards ● Copper: (2) x 1000Base-T
● Copper: (4) x 10GBase-T
● Fiber: (2) x 1 000Base-SX

40 ProxySG Quick Start Guide


Appendix A: Product Information

ProxySG 8100 LEDs


ProxySG 8100 appliances feature front‐panel LEDs that indicate power, system, 
interface, and hard disk status, and LEDs on each back‐panel network interface that 
indicate link status and speed:
8100 Front Panel LEDs

Interfaces

0 System

Power Button
Power
0 1

1 2 3 4 5 6 7 8

Hard Disk

LED Description

Power Off: Powered off


Amber: Loading OS
Amber/Green: Unconfigured
Green: Powered on and configured

System Off: No status


Green: Healthy
Amber: Warning
Flashing Amber: Critical Warning

Interfaces Flicker indicates link activity


Off: No link
Orange: 10 Mbps
Blue: 100 Mbps
Purple: 1000 Mbps

Hard Disk Off: Not connected


Green: Connected (flicker indicates activity)
Amber: Activity
Green/Amber, irregular interval: Activity
Green/Amber, regular interval: Offline or faulty
Amber, regular interval: Drive can be removed

ProxySG Quick Start Guide 41


Appendix A: Product Information

LED Description

Interfaces (back panel) Flicker indicates link activity


Green: 10 Mbps
Speed Activity Yellow: 100 Mbps
Orange: 1000 Mbps

42 ProxySG Quick Start Guide


Appendix A: Product Information

 ProxySG Maintenance and Security

The following sections contain maintenance and security information about ProxySG 
models:
• “Accessing the Command Line Interface (CLI)” on page 43
• “Securing the Front Panel Keypad” on page 43
• “Restoring to Factory Defaults” on page 44

Accessing the Command Line Interface (CLI)


In addition to its graphical user interfaces, ProxySG appliances can be accessed and 
configured through a Command Line Interface (CLI). To access the CLI:
1. Connect a null modem (serial) cable between a computer or terminal and the serial 
port on the ProxySG.
2. If not already powered on, connect the ProxySG to power and toggle the power 
switch (on models without power switches, the appliance will power on 
immediately).
3. Launch and configure the terminal or terminal emulation software (such as 
HyperTerminal):
■ Baud rate: 9600 bps
■ Parity: None
■ Flow control: None
■ Data bits: 8
■ Stop bits: 1
4. Press <Enter> three times to activate the serial console and display the SG Appliance 
Serial Console menu
5. Select Command Line Interface.

Securing the Front Panel Keypad


You can configure ProxySG appliances with a personal identification number (PIN) to 
restrict unauthorized access through the front panel LCD and keypad. Do the following 
to require anyone accessing the ProxySG appliance through the front panel keypad to 
enter a four‐digit PIN:
1. Access the CLI using the serial port (see “Accessing the Command Line Interface 
(CLI)” on page 43).
2. Enter the Administrator username and password when prompted.
3. Enable privileged mode:
a. Enter enable.
b. If configured during setup, enter the enable password.

ProxySG Quick Start Guide 43


Appendix A: Product Information

4. Specify a PIN in either cleartext or hashed format:
SGOS# (config) security front-panel-pin PIN
or
SGOS# (config) security hashed-front-panel-pin hashed_PIN
where PIN is an access code displayed in cleartext, and hashed_PIN is an access code 
displayed as hash marks (#).

Restoring to Factory Defaults


You can restore the ProxySG appliance to its factory default settings using the CLI, the 
Management Console, or the front panel keypad (ProxySG 510 and 810 models only).
• “Restore Defaults Using the CLI” on page 44
• “Restore Defaults Using the Management Console” on page 44
• “Restore Defaults Using the Front Panel Keypad” on page 45

Restore Defaults Using the CLI


1. Access the CLI using the serial port (see “Accessing the Command Line Interface 
(CLI)” on page 43).
2. Enter the username and password when prompted.
3. Enable privileged mode:
a. Enter enable.
b. If configured during setup, enter the enable password.
4. Restore the ProxySG to its factory default settings:
SGOS# (config) restore-defaults factory-defaults
Once the appliance restarts and completes its power‐on process, continue with 
“Step 2: Configuring the ProxySG” on page 15.

Restore Defaults Using the Management Console


1. Using HTTPS, access the ProxySG appliance using a Web browser:
https://ip_address:8082
where ip_address is the IP address assigned to the appliance.
 Note: If you configured your ProxySG appliance for an in-path acceleration deployment
using SGOS 5.4.x or higher, the default interface is the Sky Management Console. Access
the Management Console on the Configuration tab by clicking the Advanced
Configuration button.

2. Select Maintenance > System and Disks.


3. In the Tasks panel, click Restore.

44 ProxySG Quick Start Guide


Appendix A: Product Information

Once the appliance restarts and completes its power‐on process, continue with 
“Step 2: Configuring the ProxySG” on page 15.

Restore Defaults Using the Front Panel Keypad


On ProxySG 510 and 810 models, press and hold the left arrow button ( ) for five 
seconds to restore factory default settings.

Hold 5 seconds to restore factory defaults

1 2 0 1

MENU

Once the appliance restarts and completes its power‐on process, continue with “Step 2: 
Configuring the ProxySG” on page 15.

ProxySG Quick Start Guide 45


Appendix A: Product Information

Support and Warranty


All hardware products come with a limited, non‐transferable, one‐year warranty. 
Software is warranted for 90 days. Blue Coat warrants that the products will be free from 
material defects in manufacturing and materials and perform substantially in 
conformance with their published specifications during the warranty period. Any Third 
Party products provided under this Agreement shall be subject exclusively to the 
licensor warranty for such products.
This warranty excludes damage or failure resulting from abuse, misuse, alteration or 
unauthorized movement, acts of nature or disaster, or unauthorized repair or 
installation. Blue Coat does not warrant that the operation of products will be 
uninterrupted or error free or that the products are not vulnerable to fraud or 
unauthorized use.
Blue Coat shall not be responsible for any software, firmware, information or memory 
data contained in, stored on or integrated with any hardware or software returned to 
Blue Coat. Prior to returning any products to Blue Coat, Customer shall completely 
erase all of Customerʹs confidential information from any storage media. Customer shall 
indemnify and hold Blue Coat harmless from any claim, loss, cost, expense, demand or 
damage, including reasonable attorneysʹ fees, arising from Customerʹs non‐compliance 
with this requirement.
For additional support and warranty information, visit
http://www.bluecoat.com/support/supportpolicies/warranty

Regulatory Compliance
ProxySG appliances comply with the following emissions, safety, and standards:

Regulation Compliance

Emissions 210, 510, 810, 8100: FCC Class A, EN55022 Class A, VCCI Class A No.1706609, BSMI, CCC, C-tick

Safety 210, 510, 810, 8100: UL 60950 3rd Edition, EN60950, TUV-GS, TUV-S, CCC, BSMI

46 ProxySG Quick Start Guide


Appendix A: Product Information

Declaration of Conformity

We, Blue Coat Systems, 420 North Mary Avenue, Sunnyvale, CA 94085, declare under 
our sole responsibility that the equipment specified below:

ProxySG 210, ProxySG 510, ProxySG 810, ProxySG 8100

Is in conformity with the essential requirements of EU directives, including all 
amendments, and national legislation implementing these directives:
• 73/23/EEC
• 89/336/EEC
• 93/68/EEC
• Directive 2002/95/EC, Restriction of Hazardous Substances (RoHS).

By applying the following standards:
• EN 60950‐1: 2001+A11
• EN 55022: 1998+A1:2000+A2:2003
• EN 55024: 1998+A1:2001+A2:2003

Place of declaration: Sunnyvale, CA 94085
Date of declaration: 1 June 2006
By: Tim Redjaian, Director of Engineering

Contact Address: 420 North Mary Avenue, Sunnyvale, CA 94085-4121, USA


Toll-free from USA: 866.30.BCOAT (22627) | Direct: +1.408.220.2200 | Fax: +1.408.220.2250

ProxySG Quick Start Guide 47


Appendix A: Product Information

Proper Disposal of Electrical Equipment


To reduce waste and to protect the environment from hazardous materials, 
waste electrical equipment must be disposed of properly. 
The crossed‐out wheelie bin symbol pictured here and labeled on Blue 
Coat products is a reminder that electrical equipment should not be mixed 
in with general trash or disposed of in a landfill. Once your Blue Coat 
product or component has reached its end‐of‐life, you should dispose of it 
through a reputable, licensed hazardous materials processor.
If you are located in one of the European Union Member States, please refer to the 
product’s end user license agreement for further information regarding the proper 
disposal, reporting, and/or return of the product to Blue Coat. 
For additional information and to obtain return instructions, see:
http://www.bluecoat.com/company/environmentalsafety

48 ProxySG Quick Start Guide


Appendix B: Safety Notices

! Important: Any modification to this product, unless expressly approved by Blue Coat Systems, Inc., could
void the user’s authority to operate the equipment.
In this section:
• “General Safety Information” on page 50
• “General System Cautions” on page 70
• “Warnings and Compliance Statements” on page 70

ProxySG Quick Start Guide 49


Appendix B: Safety Notices

General Safety Information


• “English: Server Safety Information” on page 50
• “Deutsch: Sicherheitshinweise für den Server” on page 54
• “Français: Consignes de sécurité sur le serveur” on page 58
• “Español: Información de seguridad del servidor” on page 62
• “Chinese: Server Safety Information” on page 66

English: Server Safety Information


This document applies to Server Boards, Server Chassis (pedestal and rack-mount) and installed peripherals. To reduce the risk of bodily injury,
electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in this guide before installing or
maintaining your server product.
In the event of a conflict between the information in this document and information provided with the product or on the website for a partic-
ular product, the product documentation takes precedence.
Your server should be integrated and serviced only by technically qualified persons.
You must adhere to the guidelines in this guide and the assembly instructions in your server manuals to ensure and maintain compliance with
existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products /
components will void the UL Listing and other regulatory approvals of the product, and may result in noncompliance with product regulations
in the region(s) in which the product is sold.

Safety Warnings & Cautions


To avoid personal injury or property damage, before you begin installing the product, read, observe, and adhere to all of the following safety
instructions and information. The following safety symbols may be used throughout the documentation and may be marked on the product
and/or the product packaging.

CAUTION Indicates the presence of a hazard that may cause minor personal injury or property damage if the CAUTION
is ignored.

WARNING Indicates the presence of a hazard that may result in serious personal injury if the WARNING is ignored.

! Indicates potential hazard if indicated information is ignored.

, Indicates shock hazards that result in serious injury or death if safety instructions are not followed.

. Indicates hot components or surfaces.

{ Indicates do not touch fan blades, may result in injury.

Indicates to unplug all AC power cord(s) to disconnect AC power.

50 ProxySG Quick Start Guide


Appendix B: Safety Notices

Intended Application Uses


This product was evaluated as Information Technology Equipment (ITE), which may be installed computer rooms. The suitability of this prod-
uct for other product categories and environments (such as medical, industrial, residential, alarm systems, and test equipment), other than
an ITE application, may require further evaluation.

Site Selection
The system is designed to operate in a typical office environment. Choose a site that is:
• Clean, dry, and free of airborne particles (other than normal room dust).
• Well-ventilated and away from sources of heat including direct sunlight and radiators.
• Away from sources of vibration or physical shock.
• Isolated from strong electromagnetic fields produced by electrical devices.
• In regions that are susceptible to electrical storms, we recommend you plug your system into a surge suppressor and disconnect
telecommunication lines to your modem during an electrical storm.
• Provided with a properly grounded wall outlet.
• Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect.

Equipment Handling Practices


Reduce the risk of personal injury or equipment damage:
• Conform to local occupational health and safety requirements when moving and lifting equipment.
• Use mechanical assistance or other suitable assistance when moving and lifting equipment.
• To reduce the weight for easier handling, remove any easily detachable components.
• Do not lift or move the equipment by its handles.

Power and Electrical Warnings


!, CAUTION
The power button, indicated by the stand-by power marking, DOES NOT completely turn off the system AC power, 5V standby power is active
whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may
use more than one AC power cord. Make sure all AC power cords are unplugged. Make sure the AC power cord(s) is/are unplugged before you
open the chassis, or add or remove any non hot-plug components.
Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each system power
supply.
The power supply in this product contains no user-serviceable parts. Do not open the power supply. Hazardous voltage, current and energy
levels are present inside the power supply. Return to manufacturer for servicing.
When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing it from the server.
To avoid risk of electric shock, turn off the server and disconnect the power cord, telecommunications systems, networks, and modems at-
tached to the server before opening it.

Power Cord Warnings


If an AC power cord was not provided with your product, purchase one that is approved for use in your country (16 AWG recommended, 18
AWG only in lengths under 2 meters).

ProxySG Quick Start Guide 51


Appendix B: Safety Notices

!, CAUTION
To avoid electrical shock or fire, check the power cord(s) that will be used with the product as follows:
• Do not attempt to modify or use the AC power cord(s) if they are not the exact type required to fit into the grounded electrical outlets
• The power cord(s) must meet the following criteria:
• The power cord must have an electrical rating that is greater than that of the electrical current rating marked on the product.
• The power cord must have safety ground pin or contact that is suitable for the electrical outlet.
• The power supply cord(s) is/are the main disconnect device to AC power. The socket outlet(s) must be near the equipment and readi-
ly accessible for disconnection.
• The power supply cord(s) must be plugged into socket-outlet(s) that is /are provided with a suitable earth ground.

System Access Warnings


!, CAUTION
To avoid personal injury or property damage, the following safety instructions apply whenever accessing the inside of the product:
• Turn off all peripheral devices connected to this product.
• Turn off the system by pressing the power button to off.
• Disconnect the AC power by unplugging all AC power cords from the system or wall outlet.
• Disconnect all cables and telecommunication lines that are connected to the system.
• Retain all screws or other fasteners when removing access cover(s). Upon completion of accessing inside the product, refasten ac-
cess cover with original screws or fasteners.
• Do not access the inside of the power supply. There are no serviceable parts in the power supply. Return to manufacturer for servic-
ing.
• Power down the server and disconnect all power cords before adding or replacing any non hot-plug component.
• When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing the power
supply from the server.
!. CAUTION
If the server has been running, any installed processor(s) and heat sink(s) may be hot. Unless you are adding or removing a hot-plug compo-
nent, allow the system to cool before opening the covers. To avoid the possibility of coming into contact with hot component(s) during a hot-
plug installation, be careful when removing or installing the hot-plug component(s).
!{ CAUTION
To avoid injury do not contact moving fan blades. If your system is supplied with a guard over the fan, do not operate the system without the
fan guard in place.

Rack Mount Warnings


The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended
from it. The equipment rack must be installed according to the rack manufacturer's instructions.
Install equipment in the rack from the bottom up, with the heaviest equipment at the bottom of the rack.
Extend only one piece of equipment from the rack at a time.
You are responsible for installing a main power disconnect for the entire rack unit. This main disconnect must be readily accessible, and it must
be labeled as controlling power to the entire unit, not just to the server(s).
To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it.

52 ProxySG Quick Start Guide


Appendix B: Safety Notices

When rack-mounting the ProxySG, consider the following:


A. Elevated Operating Ambient—If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tmax) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation
of the equipment is not compromised.
C) Mechanical Loading—Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to
uneven mechanical loading.
D) Circuit Overloading—Consideration should be given to the connection of the equipment to the supply circuit and the effect that
overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
E) Reliable Earthing —Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given
to supply connections other than direct connections to the branch circuit (for example, use of power strips).

Electrostatic Discharge (ESD)


!, CAUTION
ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures at an ESD workstation. If one is not avail-
able, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground -- any unpainted metal surface -- on your
server when handling parts.
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its pro-
tective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if avail-
able but not the board wrapper. Do not slide board over any surface.

Battery Replacement
! CAUTION
There is the danger of explosion if the battery is incorrectly replaced. When replacing the battery, use only the battery recommended by the
equipment manufacturer.
Dispose of batteries according to local ordinances and regulations. Do not attempt to recharge a battery.
Do not attempt to disassemble, puncture, or otherwise damage a battery.

Cooling and Airflow


Carefully route cables as directed to minimize airflow blockage and cooling problems.
For proper cooling and airflow, operate the system only with the chassis covers installed. Operating the system without the covers in place can
damage system parts. To install the covers:
1. Check first to make sure you have not left loose tools or parts inside the system.
2. Check that cables, add-in boards, and other components are properly installed.
3. Attach the covers to the chassis according to the product instructions.

ProxySG Quick Start Guide 53


Appendix B: Safety Notices

Deutsch: Sicherheitshinweise für den Server


Das vorliegende Dokument bezieht sich auf Serverplatinen, Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält
Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von
Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Serverprodukt installieren oder warten.
Bei Widersprüchen zwischen den hier vorliegenden Angaben und den Informationen im Lieferumfang des Produkts oder auf der Website des
betreffenden Produkts hat die Produktdokumentation Vorrang.
Die Integration und Wartung des Servers darf nur durch technisch qualifizierte Personen erfolgen. Um die Einhaltung der vorhandenen Zulas-
sungen und Genehmigungen für das Produkt zu gewährleisten, sind die Richtlinien in diesem Handbuch sowie die Montageanleitungen in
den Serverhandbüchern zu beachten. Verwenden Sie nur die beschriebenen, zugelassenen Komponenten, die im vorliegenden Handbuch an-
gegeben werden. Die Verwendung anderer Produkte oder Komponenten führt zum Erlöschen der UL-Zulassung und anderer Genehmigungen
für das Produkt. Dadurch kann das Produkt gegen Produktbestimmungen verstoßen, die im Verkaufsland gelten.

Sicherheitshinweise und Vorsichtsmaßnahmen


Um Verletzungen und Beschädigungen zu vermeiden, sollten Sie vor dem Beginn der Produktinstallation die nachfolgend aufgeführten
Sicherheitshinweise und -informationen sorgfältig lesen und befolgen. In dem vorliegenden Handbuch sowie auf dem Produkt und auf der
Verpackung werden folgende Sicherheitssymbole verwendet:.

VORSICHT Weist auf eine Gefahrenquelle hin, die bei Nichtbeachtung des VORSICHTSHINWEISES zu leichteren Verletzun-
gen bzw. Sachbeschädigungen führen kann.

WARNUNG Weist auf eine Gefahrenquelle hin, die bei Nichtbeachtung der WARNUNG zu ernsten Verletzungen führen
kann.

! Weist auf potentielle Gefahr bei Nichtbeachtung der angezeigten Informationen hin.

Weist auf die Gefahr eines Stromschlags hin, der bei Nichtbeachtung der Sicherheitshinweise zu schweren
, oder tödlichen Verletzungen führen kann.

. Weist auf Verbrennungsgefahr an heißen Bauteilen bzw. Oberflächen hin.

{ Weist darauf hin, daß das Anfassen des Gebläses zu Verletzungen führen kann.

Bedeutet, alle Netzkabel abzuziehen und das Gerät von der Netzspannung zu trennen.

Zielbenutzer der Anwendung


Dieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Büros, Schulen, Computerräumen und ähnlichen öffentlichen Räum-
lichkeiten installiert werden kann. Die Eignung dieses Produkts für andere Einsatzbereiche als IT (z. B. Medizin, Industrie, Alarmsysteme oder
Prüfgeräte) kann u. U. weitere Tests erfordern.

Standortauswahl
Das System ist für den Betrieb innerhalb normaler Büroumgebungen geeignet. Wählen Sie einen Standort, der folgenden Kriterien entspricht:
• Sauber, trocken und frei von Partikeln in der Luft (außer dem normalen Raumstaub).
• Gut belüftet, nicht in der Nähe von Wärmequellen und keiner direkten Sonnenbestrahlung ausgesetzt.

54 ProxySG Quick Start Guide


Appendix B: Safety Notices

• Nicht in der Nähe von Vibrations- oder Erschütterungsquellen.


• Abgeschirmt von starken elektromagnetischen Feldern, die durch elektrische Geräte erzeugt werden.
• In gewittergefährdeten Gebieten sollten Sie das System an einen Überspannungsschutz anschließen und bei einem Gewitter die
Telekommunikationskabel zum Modem abziehen.
• Eine ordnungsgemäß geerdete Wandsteckdose muß vorhanden sein.
• Ausreichender Freiraum für den Zugang zu den Netzkabeln, da diese die Hauptvorrichtung zum Trennen des Produkts von der
Stromversorgung sind.

Handhabung von Geräten


Beachten Sie zur Vermeidung von Verletzungen oder Beschädigungen an den Geräten die folgenden Hinweise:
• Halten Sie beim Transportieren und Anheben von Geräten die örtlichen Gesundheits- und Sicherheitsvorschriften ein.
• Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten.
• Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleich-
tern.

Warnungen zu Netzspannung und Elektrizität


!, VORSICHT
Durch Betätigen der mit dem Standby-Symbol gekennzeichneten Netztaste wird das System NICHT vollständig vom Netz getrennt. Es sind
weiterhin 5 V aktiv, solange das System eingesteckt ist. Um das System vollständig vom Strom zu trennen, muß das Netzkabel aus der Steck-
dose abgezogen werden. Das System verfügt möglicherweise über mehrere Netzkabel. Vergewissern Sie sich in diesem Fall, daß alle Netzkabel
abgezogen sind. Wenn Sie Komponenten ein- oder ausbauen möchten, die nicht hot-plug-fähig sind, stellen Sie sicher, daß zuvor alle Netzk-
abel abgezogen sind.
Nehmen Sie keine Änderungen am Netzkabel vor, und verwenden Sie kein Kabel, das nicht genau dem geforderten Typ entspricht. Jedes Netz-
teil im System muß über ein eigenes Netzkabel angeschlossen werden.
Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden können. Öffnen Sie das Netzteil nicht. Im Netzteil be-
stehen gefährliche Spannungen, Ströme und Energiequellen. Schicken Sie das Gerät für Wartungsarbeiten an den Hersteller zurück.
Wenn Sie ein hot-plug-fähiges Netzteil austauschen, ziehen Sie dessen Netzkabel ab, bevor Sie es aus dem Server ausbauen.
Zur Vermeidung von Stromschlägen schalten Sie den Server aus, und trennen Sie vor dem Öffnen des Geräts das Netzkabel sowie alle an den
Server angeschlossene Telekommunikationssysteme, Netzwerke und Modems.

Hinweis für Netzkabel


Wenn kein Netzkabel mit dem Produkt geliefert wurde, kaufen Sie ein Kabel, das für die Benutzung in Ihrem Land zugelassen ist.
!, VORSICHT
Prüfen Sie zur Vermeidung von Stromschlag- oder Feuergefahr die mit dem Produkt zu verwendenden Netzkabel wie folgt:
• Nehmen Sie keine Änderungen an einem Netzkabel vor, und benutzen sie es nicht, wenn es nicht genau in die geerdeten Netzsteck-
dosen paßt.
• Netzkabel müssen die folgenden Anforderungen erfüllen:
• Die Nennbelastbarkeit des Netzkabels muß mindestens so hoch sein wie die am Produkt angegebenen Nennstromaufnahme.
• Das Netzkabel muß einen zur Netzsteckdose passenden Schutzkontakt besitzen.

ProxySG Quick Start Guide 55


Appendix B: Safety Notices

• Die Netzkabel sind die Hauptvorrichtung zum Trennen des Geräts vom Stromnetz. Die Steckdose muß in der Nähe der Anlage an-
gebracht und gut erreichbar sein.
• Netzkabel müssen an eine ordnungsgemäß geerdete Steckdose angeschlossen sein.

Warnhinweise für den Systemzugang


!, VORSICHT
Um Verletzungen und Beschädigungen zu vermeiden, sollten Sie vor Arbeiten im Produktinneren folgende Sicherheitsanweisungen beacht-
en:
• Schalten Sie alle am Produkt angeschlossenen Peripheriegeräte aus.
• Schalten Sie das System mit dem Netzschalter aus.
• Trennen Sie das Gerät von der Stromquelle, indem Sie alle Netzkabel vom System bzw. aus der Steckdose ziehen.
• Ziehen Sie alle Kabel und alle an das System angeschlossenen Telekommunikations- leitungen ab.
• Bewahren Sie alle Schrauben und anderen Befestigungselemente gut auf, nachdem Sie die Gehäuseabdeckung entfernt haben.
Wenn Sie Ihre Arbeiten im Systeminneren beendet haben, befestigen Sie die Gehäuseabdeckung mit den Originalschrauben bzw.
- befestigungselementen.
• Führen Sie keine Arbeiten im Netzteil aus. Das Netzteil enthält keine für den Benutzer wartungsbedürftigen Teile. Schicken Sie das
Gerät für Wartungsarbeiten an den Hersteller zurück.
• Schalten Sie den Server aus, und ziehen Sie alle Netzkabel ab, bevor Sie Komponenten ein- oder ausbauen, die nicht hot-plug-fähig
sind.
• Wenn Sie ein hot-plug-fähiges Netzteil austauschen, ziehen Sie dessen Netzkabel ab, bevor Sie es aus dem Server ausbauen.
!. VORSICHT
War Ihr Server in Betrieb, können die installierten Prozessoren und Kühlkörper heiß sein. Sofern Sie keine Hot-Plug-Komponenten ein- oder
ausbauen, warten Sie mit dem Abnehmen der Abdeckungen, bis das System abgekühlt ist. Gehen Sie beim Aus- oder Einbauen von Hot-Plug-
Komponenten sorgfältig vor, um nicht mit heißen Komponenten in Berührung zu kommen.
!{ VORSICHT
Berühren Sie nicht die rotierenden Lüfterflügel, um Verletzungen zu vermeiden. Falls Ihr System mit eine Lüfterabdeckung besitzt, darf es
nicht ohne diese Abdeckung betrieben werden.

Warnhinweise für Racks


Das Geräte-Rack muß auf einer geeigneten, festen Unterlage verankert werden, um ein Umkippen zu vermeiden, wenn ein Server oder andere
Geräte herausgezogen werden. Bei der Installation des Racks müssen die Anweisungen des Rack-Herstellers beachtet werden.
Gehen Sie bei der Installation von Geräten im Rack immer von unten nach oben vor, und bauen Sie das schwerste Gerät an der untersten Po-
sition im Rack ein.
Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus.
Sie müssen für die gesamte Rack-Einheit einen Netztrennschalter einrichten. Dieser Netztrennschalter muß leicht zugänglich sein und über
eine Kennzeichnung verfügen, die besagt, daß er die Stromzufuhr zur gesamten Einheit steuert und nicht nur zu den Servern.
Zur Vermeidung von Stromschlaggefahr müssen das Rack selbst und alle darin eingebauten Geräte ordnungsgemäß geerdet sein.

Elektrostatische Entladungen (ESD)


!, VORSICHT

56 ProxySG Quick Start Guide


Appendix B: Safety Notices

Elektrostatische Entladungen können zur Beschädigung von Festplatten, Platinen und anderen Komponenten führen. Daher sollten Sie alle
Arbeiten an einer ESD-Workstation ausführen. Steht ein solcher Arbeitsplatz nicht zur Verfügung, erzielen Sie einen gewissen Schutz vor ele-
ktrostatischen Entladungen durch Tragen einer Antistatik-Manschette, die Sie während der Arbeit zur Erdung an einem beliebigen unlacki-
erten Metallteil des Computergehäuses befestigen.
Gehen Sie bei der Handhabung von Platinen immer mit größter Vorsicht vor. Sie können äußerst empfindlich gegenüber elektrostatischer En-
tladung sein. Halten Sie Platinen nur an den Kanten fest. Legen Sie die Platinen nach dem Auspacken aus der Schutzhülle oder nach dem Aus-
bau aus dem Server mit der Bauelementseite nach oben auf eine geerdete, statisch entladene Unterlage. Verwenden Sie dazu, sofern
verfügbar, eine leitfähige Schaumstoffunterlage, aber nicht die Schutzhülle der Platine. Ziehen Sie die Platine nicht über eine Fläche.

Batterieaustausch
! VORSICHT
Wird die Batterie unsachgemäß ausgetauscht, besteht Explosionsgefahr. Verwenden Sie als Ersatz nur die vom Gerätehersteller empfohlene
Batterie.
Beachten Sie bei der Entsorgung von Batterien die gültigen Bestimmungen. Versuchen Sie nicht, eine Batterie aufzuladen.
Versuchen Sie nicht, eine Batterie zu öffnen oder sonstwie zu beschädigen.

Kühlung und Luftstrom


! VORSICHT
Verlegen Sie Kabel sorgfältig entsprechend der Anleitung, um Störungen des Luftstroms und Kühlungsprobleme zu vermeiden.
Zur Gewährleistung des ordnungsgemäßen Kühlungs- und Luftstromverhaltens darf das System nur mit angebrachten Gehäuseabdeckungen
betrieben werden. Die Inbetriebnahme des Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen
Sie die Abdeckung wieder an:
1. Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben.
2. Prüfen Sie, ob Kabel, Erweiterungskarten sowie weitere Komponenten ordnungsgemäß angebracht sind.
3. Befestigen Sie die Abdeckungen am Gehäuse des Produkts, wie in dessen Anleitung beschrieben.

ProxySG Quick Start Guide 57


Appendix B: Safety Notices

Français: Consignes de sécurité sur le serveur


Ce document s’applique aux cartes serveur, au châssis de serveur (sur pieds et sur rack) et aux périphériques installés. Pour réduire les risques
de dommages corporels, d’électrocution, d’incendie et de dommages matériels, lisez ce document et respectez tous les avertissements et pré-
cautions mentionnés dans ce guide avant d’installer ou de mettre à jour votre produit serveur.
En cas de conflit entre les informations fournies dans ce document et celles livrées avec le produit ou publiées sur le site Web pour un produit
particulier, la documentation du produit prime.
Votre serveur doit être intégré et entretenu uniquement par des techniciens qualifiés.
Vous devez suivre les informations de ce guide et les instructions d’assemblage des manuels de serveur pour vérifier et maintenir la conformité
avec les certifications et approbations de produit existantes. Utilisez uniquement les composants décrits et réglementés spécifiés dans ce
guide. L’utilisation d’autres produits/composants annulera la liste UL et les autres approbations réglementaires du produit, et le produit peut
ne pas être conforme aux autres lois et réglementations locales applicables au produit.

Sécurité : avertissements et mises en garde


Pour éviter de vous blesser ou d’endommager votre équipement, lisez et respectez toutes les informations et consignes de sécurité avant de
commencer l’installation du produit. Les symboles de sécurité suivants peuvent être utilisés tout au long de cette documentation et peuvent
figurer sur le produit ou sur son emballage..

ATTENTION Indique la présence d’un risque pouvant entraîner des blessures physiques mineures ou endommager
légèrement le matériel si la mise en garde n’est pas prise en compte.

AVERTISSEMENT Indique la présence d’un risque pouvant entraîner des blessures corporelles graves si l’avertissement n’est
pas pris en compte.

! Indique un risque potentiel si les informations signalées ne sont pas prises en compte.

Indique des risques d’électrocution pouvant entraîner des blessures corporelles graves ou mortelles si les
, consignes de sécurité ne sont pas respectées.

. Signale des composants ou des surfaces soumis à des températures élevées.

{ Indique de ne pas toucher aux pales de ventilateur, car cela peut entraîner des blessures.

Indique de débrancher tous les cordons d’alimentation secteur pour déconnecter l’alimentation.

Domaines d’utilisation prévus


Ce produit a été testé comme équipement informatique (ITE) et peut être installé dans des bureaux, des écoles, des salles informatiques et des
endroits commerciaux similaires. L’utilisation du présent produit dans des catégories et environnements de produits et domaines d’application
(par exemple, le domaine médical, industriel, résidentiel, les systèmes d’alarme et les appareils de contrôle) autres qu’ITE doit faire l’objet
d’évaluations supplémentaires.

Sélection d’un emplacement


Le système est conçu pour fonctionner dans un environnement standard de bureau. Choisissez un emplacement respectant les conditions sui-
vantes :

58 ProxySG Quick Start Guide


Appendix B: Safety Notices

• Propre, sec et exempt de particules en suspension (autres que la poussière normale d’une pièce).
• Bien ventilé et à l’écart des sources de chaleur telles que la lumière directe du soleil et les radiateurs.
• À l’écart des sources de vibration ou des chocs physiques.
• Isolé des champs électromagnétiques importants produits par des appareils électriques.
• Dans les régions sujettes aux orages magnétiques, nous vous recommandons de brancher votre système à un suppresseur de
surtension et de déconnecter les lignes de télécommunication de votre modem pendant les orages.
• Équipé d’une prise murale reliée à la terre.
• Équipé d’un espace suffisant pour accéder aux cordons d’alimentation secteur, car ils servent de disjoncteur principal d’alimentation
du produit.

Pratiques de manipulation de l’équipement


Réduisez le risque de dommages personnels ou matériels :
• Conformez-vous aux exigences de médecine du travail et de sécurité lorsque vous déplacez et soulevez le matériel.
• Utilisez l’assistance mécanique ou toute autre assistance appropriée lorsque vous déplacez et soulevez le matériel.
• Pour réduire le poids en vue de faciliter la manipulation, retirez tout composant amovible.

Alimentation et avertissements en matière d’électricité


!, ATTENTION
Le bouton d’alimentation, indiqué par le symbole de mise en veille, NE COUPE PAS complètement l’alimentation secteur du système car le cou-
rant de veille 5 V reste actif lorsque le système est sous tension. Pour couper l’alimentation du système, vous devez débrancher le cordon d’al-
imentation secteur de la prise murale. Votre système peut utiliser plusieurs cordons d’alimentation secteur. Assurez-vous que tous les cordons
d’alimentation sont débranchés. Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable
à chaud.
N’essayez pas de modifier ou d’utiliser un cordon d’alimentation secteur s’il ne s’agit pas du type exact requis. Un cordon secteur est requis pour
chaque alimentation système.
Le bloc d’alimentation de ce produit ne contient aucun composant réparable par l’utilisateur. N’ouvrez pas le bloc d’alimentation. L’intérieur
de celui-ci est soumis à des niveaux dangereux de tension, de courant et d’énergie. Renvoyez-le au fabricant en cas de problème.
Lorsque vous remplacez un bloc d’alimentation à chaud, débranchez le cordon du bloc d’alimentation en cours de remplacement avant de le
retirer du serveur.
Pour éviter tout risque d’électrocution, mettez le système hors tension et débranchez les cordons d’alimentation ainsi que les systèmes de télé-
communication, réseaux et modems reliés au système avant d’ouvrir ce dernier.

Avertissements sur le cordon d’alimentation


Si aucun cordon d’alimentation secteur n’a été fourni avec votre produit, vous devez vous en procurer un qui soit approuvé pour une utilisation
dans votre pays.
!, ATTENTION
Pour éviter tout risque d’électrocution ou d’incendie, vérifiez les cordons d’alimentation qui seront utilisés avec le produit comme suit :
• N’essayez pas d’utiliser ou de modifier les cordons d’alimentation en CA s’ils ne correspondent pas exactement au type requis pour
les prises électriques reliées à la terre.
• Les cordons d’alimentation doivent répondre aux critères suivants :

ProxySG Quick Start Guide 59


Appendix B: Safety Notices

• Le cordon d’alimentation doit supporter une intensité supérieure à celle indiquée sur le produit.
• Le cordon d’alimentation doit posséder une broche ou un contact de mise à la terre approprié à la prise électrique.
• Les cordons d’alimentation électrique représentent le principal dispositif de déconnexion raccordé à l’alimentation secteur. Les pris-
es de courant doivent se trouver à proximité de l’équipement et être facilement accessibles pour une déconnexion.
• Les cordons d’alimentation doivent être branchés sur des prises électriques correctement reliées à la terre.

Avertissements sur l’accès au système


!, ATTENTION
Pour éviter de vous blesser ou d’endommager votre équipement, les consignes de sécurité suivantes s’appliquent chaque fois que vous accédez
à l’intérieur du produit :
• Mettez hors tension tous les périphériques connectés à ce produit.
• Éteignez le système en appuyant sur le bouton d’alimentation.
• Déconnectez l’alimentation secteur en débranchant tous les cordons d’alimentation secteur du système ou de la prise murale.
• Déconnectez l’ensemble des câbles et lignes de télécommunication qui sont connectés au système.
• Mettez toutes les vis ou autres attaches de côté lorsque vous retirez les panneaux d’accès. Une fois que vous avez terminé d’accéder
à l’intérieur du produit, refixez le panneau d’accès avec les vis ou attaches d’origine.
• N’essayez pas d’accéder à l’intérieur du bloc d’alimentation. Il ne contient aucune pièce réparable. Renvoyez-le au fabricant en cas
de problème.
• Mettez le serveur hors tension et débranchez tous les cordons d’alimentation avant d’ajouter ou de remplacer tout composant non
connectable à chaud.
• Lorsque vous remplacez le bloc d’alimentation à chaud, débranchez le cordon du bloc d’alimentation en cours de remplacement
avant de retirer le bloc du serveur.
!. ATTENTION
Si le serveur a été utilisé, les processeurs et dissipateurs de chaleur installés peuvent être chauds. À moins que vous n’ajoutiez ou ne retiriez un
composant connectable à chaud, laissez le système refroidir avant d’ouvrir les panneaux. Pour éviter tout risque d’entrer en contact avec un
composant chaud lors d’une installation à chaud, prenez toutes les précautions nécessaires lorsque vous retirez ou installez des composants
connectables à chaud.
!{ ATTENTION
Pour éviter de vous blesser, ne touchez pas les pales de ventilateur en mouvement. Si votre système est fourni avec une protection sur le ven-
tilateur, ne mettez pas le système en route sans la protection en place.

Avertissements sur le montage en rack


Le rack doit être fixé à un support inamovible pour éviter qu’il ne bascule lors de l’extension d’un serveur ou d’un élément de l’équipement. Le
rack doit être installé conformément aux instructions du fabricant.
Installez les équipements dans le rack en partant du bas, en plaçant le plus lourd en bas du rack. N’étendez qu’un seul élément de l’équipement
à partir du rack à la fois.
Vous êtes responsable de l’installation d’un disjoncteur principal d’alimentation pour la totalité du rack. Ce disjoncteur principal doit être rap-
idement accessible et doit être étiqueté comme contrôlant toute l’unité, et pas uniquement le ou les serveurs.
Pour éviter tout risque d’électrocution, le rack et chaque élément de l’équipement installé dans le rack doivent être correctement reliés à la
terre.

60 ProxySG Quick Start Guide


Appendix B: Safety Notices

Décharges électrostatiques (ESD)


!, ATTENTION
Les décharges électrostatiques (ESD) peuvent endommager les lecteurs de disque dur, les cartes et d’autres pièces. Il est fortement conseillé
d’effectuer l’ensemble des procédures décrites à un poste de travail protégé contre les ESD. Au cas où aucun poste de ce type ne serait dis-
ponible, protégez-vous contre les ESD en portant un bracelet antistatique relié à la masse du châssis (n’importe quelle surface métallique non
peinte) de votre serveur lorsque que vous manipulez les pièces.
Manipulez toujours les cartes avec précaution. Elles peuvent être extrêmement sensibles aux ESD. Ne tenez les cartes que par leurs bords. Après
avoir retiré une carte de son emballage de protection ou du serveur, placez-la sur une surface reliée à la terre, exempte de charge statique,
composants orientés vers le haut. Utilisez si possible un tapis de mousse conducteur, mais pas l’emballage de la carte. Veillez à ce que la carte
ne glisse sur aucune surface.

Remplacement de la pile
! ATTENTION
Il existe un risque d’explosion si la pile n’est pas correctement remplacée. Lors du remplacement de la pile, utilisez uniquement celle recom-
mandée par le fabricant du matériel.
Mettez la pile au rebut en vous conformant aux réglementations locales. N’essayez pas de recharger une pile.
N’essayez pas de démonter, de percer ou d’endommager la pile d’une quelconque façon.

Refroidissement et ventilation
! ATTENTION
Routez les câbles avec précaution comme indiqué pour minimiser les blocages de circulation d’air et les problèmes de refroidissement.
Afin de permettre une ventilation et un refroidissement corrects, ne mettez le système en marche que lorsque les panneaux du châssis sont
en place. L’utilisation du système sans les panneaux peut endommager les composants système. Pour installer les panneaux :
1. Vérifiez tout d’abord que vous n’avez pas oublié d’outils ou de composants détachés à l’intérieur du système.
2. Vérifiez que les câbles, les cartes d’extension et les autres composants sont correctement installés.
3. Fixez les panneaux au châssis en suivant les instructions du produit.

ProxySG Quick Start Guide 61


Appendix B: Safety Notices

Español: Información de seguridad del servidor


Este documento se aplica a las tarjetas de servidor de, las carcasas de servidor de (montaje en bastidor y en pedestal) y los dispositivos per-
iféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las
advertencias y precauciones de esta guía antes de instalar o mantener el producto de servidor de.
En el caso de que haya diferencias entre la información para un producto en particular contenida en este documento y la información propor-
cionada con dicho producto o en el sitio Web, la documentación del producto es la que prevalece.
Sólo personal técnico cualificado debe montar y prestar los servicios para el servidor.
Debe ceñirse a las directrices de esta guía y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cum-
plimiento con las certificaciones y homologaciones existentes de los productos. Utilice sólo los componentes descritos y homologados que se
especifican en esta guía. El uso de otros productos o componentes anulará la homologación UL y otras certificaciones oficiales del producto,
pudiendo dejar de ser compatible con las normativas locales de los países en los que se comercializa.

Advertencias y precauciones sobre seguridad


Para reducir la posibilidad de que se produzcan lesiones personales o daños en la propiedad, antes de empezar a instalar el producto, lea, ob-
serve y cumpla toda la información e instrucciones de seguridad siguientes. Puede que se utilicen los siguientes símbolos de seguridad en la
documentación y es posible que aparezcan en el producto o en su embalaje.

PRECAUCIÓN Indica la existencia de un riesgo que podría causar lesiones personales o daños en la propiedad leves si no
se tiene en cuenta la PRECAUCIÓN.

ADVERTENCIA Indica la existencia de un riesgo que podría causar lesiones personales graves si no se tiene en cuenta la AD-
VERTENCIA.

! Indica un riesgo potencial si no se tiene en cuenta la información indicada.

Indica riesgo de descargas eléctricas que podrían causar lesiones graves o la muerte si no se siguen las in-
, strucciones de seguridad.

. Indica componentes o superficies calientes.

Indica que no se deben tocar las aspas de los ventiladores, ya que de lo contrario se podrían producir le-
{ siones.

Indica que es necesario desenchufar los cables de alimentación de CA para desconectar la alimentación de
CA.

Aplicaciones y usos previstos


Este producto ha sido evaluado como equipo de tecnología informática (ITE) que puede instalarse en oficinas, escuelas, salas de equipos in-
formáticos o lugares de ámbito comercial similares. Es posible que sea necesario llevar a cabo una evaluación adicional para comprobar si este
producto es apropiado para otras categorías de productos y entornos además de las aplicaciones informáticas (por ejemplo, soluciones médi-
cas, industriales, residenciales, sistemas de alarma y equipos de pruebas).

Selección de la ubicación
El sistema se ha diseñado para funcionar en un entorno normal de oficinas. Seleccione una ubicación que esté:

62 ProxySG Quick Start Guide


Appendix B: Safety Notices

• Limpia, seca y libre de macropartículas en suspensión en el aire (que no sean el polvo habitual de la habitación).
• Bien ventilada y alejada de fuentes de calor, incluida la luz solar directa y los radiadores.
• Alejada de fuentes de vibración o de golpes físicos.
• Aislada de campos electromagnéticos producidos por dispositivos eléctricos.
• En zonas propensas a tormentas eléctricas, se recomienda que conecte el servidor a un supresor de sobretensiones y desconecte las
líneas de telecomunicaciones al módem durante una tormenta eléctrica.
• Provista de una toma de corriente alterna correctamente conectada a tierra.
• Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de
la alimentación.

Manipulación del equipo


Reduzca el riesgo de daños personales o en el equipo:
• Respete los requisitos de sanidad y seguridad laborales de su país cuando traslade y levante el equipo.
• Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo.
• Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción.

Advertencias de alimentación y eléctricas


!, PRECAUCIÓN
El botón de encendido, indicado con la marca del modo de reposo o stand-by, NO DESCONECTA completamente la alimentación de CA del siste-
ma, ya que el modo de reposo de 5 V sigue activo mientras el sistema está enchufado. Para desconectar el sistema debe desenchufar el cable
de alimentación de CA de la toma de la pared. Puede usar más de un cable de alimentación de CA con el sistema. Asegúrese de que todos los
cables de alimentación de CA están desenchufados. Asegúrese de que los cables de alimentación de CA estén desenchufado antes de abrir la
carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento.
No intente modificar ni utilizar un cable de alimentación de CA si no es del tipo exacto requerido. Se necesita un cable de CA para cada fuente
de alimentación del sistema.
La fuente de alimentación de este producto no contiene piezas que puedan ser reparadas por el usuario. No abra la fuente de alimentación.
Dentro de la fuente de alimentación puede haber niveles de tensión, corriente y energía peligrosos. Devuélvala al fabricante para repararla.
Al reemplazar una fuente de alimentación de conexión en funcionamiento, desenchufe el cable de alimentación de la fuente de alimentación
que va a reemplazar antes de extraerla del servidor.
Para evitar el riesgo de descargas eléctricas, antes de abrir el servidor, apáguelo, desconecte el cable de alimentación, los sistemas de teleco-
municaciones, las redes y los módems conectados al mismo.

Advertencias sobre el cable de alimentación


Si no se ha proporcionado con el producto ningún cable de alimentación de CA, adquiera alguno cuyo uso esté aprobado en su país.
!, PRECAUCIÓN
Para evitar descargas eléctricas o fuego, revise los cables de alimentación que usará con el producto tal y como se describe a continuación:
• No intente modificar ni utilizar los cables de alimentación de CA si no son exactamente del modelo especificado para ajustarse a las
tomas de corriente conectadas a tierra
• Los cables de alimentación deben reunir los siguientes requisitos:

ProxySG Quick Start Guide 63


Appendix B: Safety Notices

• El cable de alimentación debe disponer de una capacidad nominal de corriente eléctrica mayor que la capacidad especificada
en el producto.
• El cable de alimentación debe disponer de una patilla o contacto de conexión a tierra que sea apto para la toma de corriente.
• Los cables de la fuente de alimentación son los dispositivos de desconexión principales a la corriente alterna. El enchufe o enchufes
de zócalo deben encontrarse cerca del equipo y el acceso a ellos debe poderse efectuar de forma inmediata con el fin de
desconectarlos.
• Los cables de la fuente de alimentación deben estar conectados a los enchufes con una toma de tierra adecuada.

Advertencias el acceso al sistema


!, PRECAUCIÓN
Para evitar lesiones personales o daños en la propiedad, se aplican las siguientes instrucciones de seguridad siempre que se acceda al interior
del producto:
• Apague todos los dispositivos periféricos conectados a este producto.
• Pulse el botón de alimentación para apagar el sistema.
• Desconecte la alimentación de CA desenchufando los cables de alimentación de CA del sistema o de la toma de corriente al-
terna.
• Desconecte todos los cables y líneas de telecomunicación que estén conectados al sistema.
• Guarde todos los tornillos o elementos de fijación cuando retire las cubiertas de acceso. Cuando termine de operar en el interior
del producto, vuelva a colocar los tornillos o los elementos de fijación originales de la cubierta de acceso.
• No acceda al interior de la fuente de alimentación. No hay elementos en la fuente de alimentación que usted pueda reparar y
utilizar. Devuélvala al fabricante para repararla.
• Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que
no es de conexión en funcionamiento.
• Al reemplazar una fuente de alimentación de conexión en funcionamiento, desenchufe el cable de alimentación de la fuente
de alimentación que va a reemplazar antes de extraerla del servidor.
!. PRECAUCIÓN
Si el servidor se ha estado ejecutando, los procesadores y disipadores de calor estarán recalentados. A no ser que esté instalando o extrayendo
un componente de conexión en funcionamiento, deje que el sistema se enfríe antes de abrir las cubiertas. Para que no llegue a tocar los com-
ponentes que estén calientes cuando esté realizando una instalación de conexión en funcionamiento, tenga cuidado al extraer o instalar los
componentes de conexión en funcionamiento.
!{ PRECAUCIÓN
Para evitar posibles daños, no toque las aspas en movimiento de los ventiladores. Si el sistema se le ha suministrado con una protección para
el ventilador, asegúrese de que cuando esté funcionando el sistema la protección esté en su sitio.

Advertencias sobre el montaje en bastidor


El bastidor del equipo se debe sujetar con un soporte fijo para evitar que se caiga cuando se extraiga un servidor o una pieza del mismo. El
bastidor del equipo debe instalarse siguiendo las instrucciones del fabricante del bastidor.
Instale el equipo en el bastidor comenzando desde la parte de abajo, con el equipo más pesado en la parte inferior del bastidor.
Extraiga las piezas del equipo del bastidor de una a una.

64 ProxySG Quick Start Guide


Appendix B: Safety Notices

El usuario es el responsable de la instalación de un dispositivo de desconexión de la alimentación principal para toda la unidad del bastidor. El
acceso a este dispositivo de desconexión deberá ser de fácil acceso y deberán incluirse indicaciones que lo identifiquen como el control de al-
imentación eléctrica de toda la unidad, no sólo de los servidores.
Para evitar el riesgo de descargas eléctricas, deberá instalar una conexión a tierra apropiada para el bastidor y para cada pieza del equipo in-
stalada en el mismo.

Descarga electrostática (ESD)


!, PRECAUCIÓN
Las descargas electrostáticas pueden dañar las unidades de disco, las tarjetas y otros componentes. Recomendamos que realice todos los pro-
cedimientos en una estación de trabajo protegida contra descargas electrostáticas. En caso de que no haya una disponible, protéjase de alguna
forma contras las descargas llevando un brazalete antiestático conectado a la toma de tierra de la carcasa (cualquier superficie de metal que
no esté pintada) del servidor cuando manipule las piezas.
Manipule siempre las tarjetas con el máximo cuidado. Pueden ser sumamente sensibles a las descargas electrostáticas. Sujételas sólo por los
bordes. Una vez extraída la tarjeta de su envoltorio de protección o del servidor, colóquela con el lado de los componentes hacia arriba sobre
una superficie con toma de tierra y sin carga estática. Utilice una almohadilla de espuma conductora si dispone de ella, pero nunca el envoltorio
de la tarjeta. No deslice la tarjeta sobre ninguna superficie.

Sustitución de la batería
! PRECAUCIÓN
Existe el peligro de explosión si la batería no se reemplaza correctamente. Al reemplazar la batería, utilice sólo la batería recomendada por el
fabricante del equipo.
Deseche las baterías respetando la normativa local.
No intente recargar la batería.
No intente desmontar, pinchar o causar cualquier otro desperfecto a una batería.

Enfriamiento y circulación de aire


! PRECAUCIÓN
El tendido de los cables debe realizarse cuidadosamente tal y como se le indica para reducir al mínimo los problemas de obstrucción de la ven-
tilación y de refrigeración.
Para conseguir una refrigeración y corriente de aire adecuadas, compruebe que cuando sistema esté funcionando, las cubiertas de la carcasa
están instaladas. Si utiliza el sistema sin las cubiertas, podría dañar sus componentes. Para instalar las cubiertas:
1. Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema.
2. Compruebe que los cables, tarjetas adicionales y otros componentes están instalados correctamente.
3. Sujete las cubiertas a la carcasa siguiendo las instrucciones del producto.

ProxySG Quick Start Guide 65


Appendix B: Safety Notices

Chinese: Server Safety Information

ㆰփѝ᮷





ᴽ࣑ಘᆹ‫ؑޘ‬᚟
ᵜ᮷ẓ䘲⭘Ҿᴽ࣑ಘѫᶯǃᴽ࣑ಘᵪ㇡˄สᓗ઼ᵪᷦപᇊԦ˅઼ᐢᆹ㻵Ⲵཆ䇮DŽѪ߿ቁӪ䓛Ք
ᇣǃ⭥ࠫǃ⚛⚮ԕ৺䇮༷⇱ൿⲴড䲙ˈ䈧൘ᆹ㻵ᡆ㔤ᣔᴽ࣑ಘӗ૱ѻࡽ䰵䈫ᵜ᮷ẓᒦ䚥ᗚᵜ
ᤷইѝⲴᡰᴹ䆖੺઼亴䱢᧚ᯭDŽ
ྲ᷌ᵜ᮷ẓѝⲴؑ᚟о⢩ᇊӗ૱Ⲵ䲿䱴ؑ᚟ᡆ:HE
ㄉ⛩ؑ᚟ѻ䰤ᆈ൘на㠤ˈ䈧ԕӗ૱᮷ẓѪ߶DŽ
ᴽ࣑ಘ享⭡ਸṬⲴᢰᵟӪઈ䘋㹼䳶ᡀ઼㔤ᣔDŽᗵ享䚥ᆸᵜᤷইⲴ㿴ᇊ઼ᴽ࣑ಘ᡻޼Ⲵ㻵䝽ᤷ
ሬˈԕ⺞‫؍‬ㅖਸ⧠ᴹⲴӗ૱䇔䇱઼ᇑᢩDŽӵ֯⭘
ᵜᤷইѝ᧿䘠઼㿴ᇊⲴᤷᇊ㓴ԦDŽ֯⭘ަԆӗ૱㓴Ԧሶ֯ӗ૱Ⲵ8/
䇔䇱઼ަԆ㇑⨶ᇑᢩᰐ᭸ˈᒦਟ㜭ሬ㠤ӗ૱нㅖਸ䬰୞ൠⲴӗ૱⌅㿴DŽ



ᆹ‫ޘ‬䆖੺о⌘᜿һ亩

Ѫ䚯‫ݽ‬Ӫ䓛Քᇣо䍒ӗᦏཡˈᆹ㻵ᵜӗ૱ѻࡽˈ䈧䰵䈫ԕлᡰᴹᆹ‫ޘ‬ᤷሬ઼ؑ᚟DŽл䶒ᡰࡇⲴ
ᆹ‫ޘ‬ㅖਧਟ㜭൘ᮤњ᮷ẓѝ֯⭘ᒦਟ㜭ḷ⌘Ҿӗ૱઼ᡆӗ૱व㻵ѻкDŽ

⌘᜿ 㺘⽪ྲ᷌ᰐ㿶↔Ā⌘᜿һ亩āˈᆈ൘ਟ㜭ᕅ䎧䖫ᗞӪ䓛Քᇣᡆ䍒ӗᦏཡⲴড䲙DŽ
䆖੺ 㺘⽪ྲ᷌ᰐ㿶↔Ā䆖੺āˈᆈ൘ਟ㜭ᕅ䎧ѕ䟽Ӫ䓛ՔᇣⲴড䲙DŽ

㺘⽪ྲ᷌ᰐ㿶ᡰ⽪ؑ᚟ˈণᆈ൘▌൘Ⲵড䲙DŽ

㺘⽪ྲ᷌н䚥ᆸᆹ‫ޘ‬ᤷሬˈᆈ൘ਟሬ㠤ѕ䟽Քᇣᡆ↫ӑⲴ⭥ࠫড䲙DŽ

㺘⽪⚬✝㓴Ԧᡆ㺘䶒DŽ

㺘⽪䈧य䀖᪨仾ᵪਦ⡷ˈ੖ࡉਟ㜭㠤ՔDŽ

㺘⽪ᤄлᡰᴹӔ⍱⭥㓯ˈᯝᔰӔ⍱⭥Ⓚ

66 ProxySG Quick Start Guide


Appendix B: Safety Notices


亴ᵏᓄ⭘֯⭘
ṩᦞ䇴ՠˈᵜӗ૱Ѫؑ᚟ᢰᵟ䇮༷ ,7( ˈਟᆹ㻵൘࣎‫ޜ‬ᇔǃᆖṑǃ䇑㇇ᵪᡯ઼㊫լⲴ୶ъ൪
ᡰDŽᵜӗ૱ሩҾ䶎,7(ᓄ⭘ⲴަԆӗ૱⿽㊫઼⧟ຳ˄ྲ५⯇ǃᐕъǃտᆵǃᣕ䆖㌫㔏઼⍻䈅䇮
༷˅Ⲵ䘲⭘ᙗቊᴹᖵ䘋а↕Ⲵ䇴ՠDŽ


൪ൠ䘹ᤙ
ᵜ㌫㔏уѪ൘ިර࣎‫⧟ޜ‬ຳ䘀㹼㘼䇮䇑DŽ䈧䘹ᤙㅖਸԕлᶑԦⲴൠ⛩˖
x ␵⌱ǃᒢ⠕ˈᰐ≄䖭ᗞ㋂˄㘼䶎а㡜Ⲵᇔ޵ቈෳ˅DŽ
x 䙊仾㢟ྭˈ䘌⿫✝Ⓚ˄वᤜⴤ᧕ᰕᲂ઼ᮓ✝ಘ˅DŽ
x 䘌⿫ᥟࣘⓀᡆ⢙⨶䴷ࣘDŽ
x о⭥≄䇮༷ӗ⭏Ⲵᕪབྷ⭥⻱൪䳄⿫DŽ
x ൘᱃ਇ䰚⭥㻝ࠫⲴൠ४ˈᡁԜᔪ䇞ሶ㌫㔏ᨂ‫⎼⭥ޕ‬ᣁࡦಘᒦ൘䰚⭥ᵏ䰤ᯝᔰ䙊ؑ㓯䐟о䈳
ࡦ䀓䈳ಘѻ䰤Ⲵ䘎᧕DŽ
x ᨀ‫᧕⺞↓׋‬ൠⲴ້໱ᨂᓗDŽ
x ᨀ‫׋‬䏣ཏⲴオ䰤ˈԕ‫ׯ‬᤯ਆ⭥Ⓚ‫׋‬ᓄ㓯ˈഐѪ䘉ᱟᵜӗ૱Ⲵѫ㾱⭥ⓀᯝᔰಘDŽ


䇮༷᫽֌㿴㤳
߿ቁӪ䓛Քᇣᡆ䇮༷ਇᦏⲴড䲙˖
x 〫Ѯ䇮༷ᰦ䚥ᆸᖃൠⲴ㙼ъ‫ڕ‬ᓧоᆹ‫ޘ‬㾱≲DŽ
x ُࣙᵪỠ᡻⇥ᡆަԆਸ䘲Ⲵ᡻⇥〫Ѯ䇮༷DŽ
x ᣶䲔а࠷᱃࠶⿫㓴Ԧˈԕ䱽վ䟽䟿ᒦᯩ‫ׯ‬᫽֌DŽ


⭥Ⓚо⭥≄䆖੺


⌘᜿һ亩
⭥Ⓚ᤹䫞˄ྲᖵᵪ⭥Ⓚḷ䇠ᡰ⽪˅ᒦн㜭ᆼ‫ޣޘ‬䰝㌫㔏ⲴӔ⍱⭥Ⓚˈਚ㾱㌫㔏ᐢ᧕䙊⭥Ⓚˈቡ
ᆈ൘9ᖵᵪ⭥ⓀDŽ㾱Ӿ㌫㔏࠷ᯝ⭥Ⓚˈ享Ӿ້໱⭥ⓀᨂᓗѝᤄлӔ⍱⭥㓯DŽᛘⲴ㌫㔏ਟ㜭н
→֯⭘аṩӔ⍱⭥㓯DŽ䈧⺞‫؍‬ᡰᴹⲴӔ⍱⭥㓯䜭ᐢᤄлDŽᢃᔰᵪ㇡ᡆ໎࣐ᡆ৫䲔ԫօ✝ᨂᤄ
㓴Ԧѻࡽˈ⺞‫؍‬Ӕ⍱⭥㓯ᐢᤄлDŽ


㤕䶎ᡰ䴰Ⲵ⺞࠷㊫රˈ䈧यቍ䈅‫؞‬᭩ᡆ֯⭘Ӕ⍱⭥㓯DŽ㌫㔏Ⲵ⇿њ⭥Ⓚ‫׋‬ᓄ䇮༷䜭䴰㾱аṩঅ
⤜ⲴӔ⍱⭥㓯DŽ
ᵜӗ૱Ⲵ⭥Ⓚ‫׋‬ᓄ䇮༷वਜ਼䶎⭘ᡧ㔤‫؞‬䜘ԦDŽ䈧यᢃᔰ⭥Ⓚ‫׋‬ᓄ䇮༷DŽ⭥Ⓚ‫׋‬ᓄ䇮༷वਜ਼䶎ᑨ
ড䲙Ⲵ⭥঻㓗ǃ⭥⍱㓗઼㜭䟿㓗DŽ䈧о⭏ӗ୶㚄㌫㔤‫؞‬һᇌDŽ
ᴯᦒ✝ᨂᤄ⭥Ⓚ‫׋‬ᓄ䇮༷ᰦˈ䈧‫ݸ‬ᤄл䴰ᴯᦒⲴ⭥Ⓚ‫׋‬ᓄ䇮༷кⲴ⭥Ⓚ㓯ˈ޽ሶަӾᴽ࣑ಘк
〫䲔DŽ

ProxySG Quick Start Guide 67


Appendix B: Safety Notices

Ѫ䚯‫ˈࠫ⭥ݽ‬䈧൘ᢃᔰᴽ࣑ಘѻࡽˈ‫ޣ‬䰝ᴽ࣑ಘᒦᯝᔰᴽ࣑ಘк䘎᧕Ⲵ⭥Ⓚ㓯ǃ⭥ؑ㌫㔏ǃ㖁
㔌઼䈳ࡦ䀓䈳ಘDŽ


⭥Ⓚ㓯䆖੺
ྲ᷌ӗ૱ᵚᨀ‫׋‬Ӕ⍱⭥㓯ˈ䈧䍝Ҡаṩᛘᡰ൘ഭᇦᢩ߶֯⭘ⲴӔ⍱⭥㓯DŽ

⌘᜿һ亩
Ѫ䚯‫ࠫ⭥ݽ‬ᡆ⚛⚮ড䲙ˈ䈧᤹ྲлᡰ䘠ሩӗ૱ᡰ⭘Ⲵ⭥Ⓚ㓯䘋㹼Ựḕ˖
x 㤕䶎ᡰ䴰Ⲵㅖਸ᧕ൠᨂᓗⲴ⺞࠷㊫රˈ䈧यቍ䈅‫؞‬᭩ᡆ֯⭘Ӕ⍱⭥㓯
x ⭥Ⓚ㓯享ㅖਸԕлḷ߶˖
 ⭥Ⓚ㓯Ⲵ⭥≄仍ᇊ٬享བྷҾӗ૱кḷ⌘Ⲵ⭥⍱仍ᇊ٬DŽ
 ⭥Ⓚ㓯享ᤕᴹ䘲ਸᨂᓗⲴᆹ‫᧕ޘ‬ൠᨂཤᡆ䀖⛩DŽ
x ⭥Ⓚ㓯ѪӔ⍱⭥ⓀⲴѫ㾱ᯝᔰ䇮༷DŽᨂᓗ享䶐䘁䇮༷ᒦਟ䲿ᰦᯝᔰDŽ
x ⭥Ⓚ㓯享ᨂ‫ޕ‬ᡰᨀ‫Ⲵ׋‬ᤕᴹਸ䘲᧕ൠⲴᨂᓗDŽ



㌫㔏֯⭘䆖੺


⌘᜿һ亩
Ѫ䚯‫ݽ‬Ӫ䓛Քᇣᡆ䍒ӗᦏཡˈᰐ䇪օᰦỰḕӗ૱޵䜘ˈԕлᆹ‫ޘ‬ᤷሬ䜭䘲⭘˖
x ‫ޣ‬䰝ᡰᴹоᵜӗ૱⴨䘎Ⲵཆ䇮DŽ
x ᤹л⭥Ⓚ᤹䫞㠣‫ޣ‬䰝⣦ᘱˈ‫ޣ‬䰝㌫㔏DŽ
x Ӿ㌫㔏ᡆ້໱ᨂᓗкᤄлᡰᴹӔ⍱⭥㓯ˈᯝᔰӔ⍱⭥ⓀDŽ
x ᯝᔰо㌫㔏⴨䘎Ⲵᡰᴹ㓯㔶઼䙊ؑ㓯䐟DŽ
x ন䲔㡡ਓⴆᰦˈ‫⮉؍‬ᡰᴹ㷪䪹৺ަԆ㍗പԦDŽᆼᡀӗ૱޵䜘Ựḕѻਾˈ䈧⭘㷪䪹ᡆ㍗
പԦ䟽ᯠപᇊ㡡ਓⴆDŽ
x 䈧यᢃᔰ⭥Ⓚ‫׋‬ᓄ䇮༷DŽ⭥Ⓚ‫׋‬ᓄ䇮༷޵⋑ᴹਟ㔤‫؞‬䜘ԦDŽ䈧о⭏ӗ୶㚄㌫㔤‫؞‬һᇌ
x ໎࣐ᡆᴯᦒԫօ䶎✝ᨂᤄ㓴Ԧѻࡽˈ䈧‫ޣ‬䰝ᴽ࣑ಘ⭥Ⓚᒦᯝᔰᡰᴹ⭥Ⓚ㓯DŽ
x ᴯᦒ✝ᨂᤄ⭥Ⓚ‫׋‬ᓄ䇮༷ᰦˈ䈧‫ݸ‬ᤄл䴰ᴯᦒⲴ⭥Ⓚ‫׋‬ᓄ䇮༷кⲴ⭥Ⓚ㓯ˈ❦ਾ޽Ӿ
ᴽ࣑ಘк〫䲔⭥Ⓚ‫׋‬ᓄ䇮༷DŽ



⌘᜿һ亩
ྲ᷌ᴽ࣑ಘаⴤ൘䘀㹼ˈԫօᐢᆹ㻵Ⲵ༴⨶ಘ઼੨✝䇮༷䜭ਟ㜭ᖸ✝DŽ䲔䶎㾱໎࣐ᡆ〫䲔✝ᨂ
ᤄ㓴Ԧˈ੖ࡉ䈧ᖵ㌫㔏ߧতਾ޽ᔰⴆDŽѪ䚯‫ݽ‬൘✝ᨂᤄ㓴Ԧᆹ㻵䗷〻ѝ᧕䀖⚬✝㓴Ԧˈ〫䲔ᡆ
ᆹ㻵✝ᨂᤄ㓴Ԧᰦ࣑享ሿᗳDŽ


⌘᜿һ亩


Ѫ䚯‫ݽ‬ਇՔˈ䈧य䀖᪨䘀䖜Ⲵ仾ᵪਦ⡷DŽྲ᷌㌫㔏Ⲵ仾ᵪк䝽ᴹ䱢ᣔ㻵㖞ˈ䈧यনл仾ᵪ䱢ᣔ
㻵㖞䘀㹼㌫㔏DŽ

68 ProxySG Quick Start Guide


Appendix B: Safety Notices


ᵪᷦപᇊԦ䆖੺
䇮༷Ⲵᵪᷦ享പᇊ൘っപⲴ᭟ᓗкˈԕ䱢Ӿѝᆹ㻵ᴽ࣑ಘᡆ䇮༷ᰦ‫ق‬๼DŽ享᤹➗ᵪᷦ⭏ӗ୶ᨀ
‫Ⲵ׋‬ᆹ㻵䈤᰾䘋㹼ᆹ㻵DŽ
Ӿлᖰкሶ䇮༷ᆹ㻵൘ᵪᷦкˈᴰ䟽Ⲵ䇮༷ᆹ㻵൘ᵪᷦⲴᴰᓅቲDŽа⅑ਚӾᵪᷦкᆹ㻵аԦ
䇮༷DŽᛘ享䍏䍓ᆹ㻵ᮤњᵪᷦ㻵㖞Ⲵѫ㾱⭥Ⓚᯝᔰ䇮༷DŽ↔ѫ㾱ᯝᔰ䇮༷享䲿ᰦਟ⭘ˈф享
ḷ᰾Ѫ᧗
ࡦᮤњ㻵㖞˄㘼нӵ䲀Ҿᴽ࣑ಘ˅Ⲵ⭥ⓀDŽ
Ѫ䚯‫▌ݽ‬൘Ⲵ⭥ࠫড䲙ˈ享ሩᵪᷦ৺ަкᡰᆹ㻵Ⲵ⇿аԦ䇮༷ᇎ㹼↓⺞Ⲵᆹ‫᧕ޘ‬ൠDŽ



䶉⭥᭮⭥ (6' 


⌘᜿һ亩
(6'Պᦏൿ⻱ⴈ傡ࣘಘǃѫᶯ৺ަԆ䜘ԦDŽᡁԜᔪ䇞ᛘᢗ㹼(6'ᐕ֌ㄉⲴᡰᴹ↕僔DŽྲ᷌⋑ᴹ
(6'ᐕ֌ㄉˈࡉ䟷ਆаӋ䶉⭥᭮⭥‫؍‬ᣔ᧚ᯭˈ᫽֌䜘Ԧᰦˈᡤкоᴽ࣑ಘкⲴᵪ㇡᧕ൠᡆԫօ
ᵚ௧┶䠁኎㺘䶒䘎᧕Ⲵ䱢䶉⭥㞅ᑖDŽ
᫽֌ѫᶯᰦ࿻㓸‫؍‬ᤱሿᗳDŽᆳԜਟ㜭ሩ(6'䶎ᑨ᭿ᝏDŽ᤯ᤱѫᶯᰦਚ᧕䀖䗩㕈DŽӾ‫؍‬ᣔव㻵
ѝᡆӾᴽ࣑ಘкਆࠪѫᶯਾˈ䈧ሶѫᶯ㓴Ԧ‫ח‬䶒ᵍк᭮㖞൘ᰐ䶉⭥Ⲵ᧕ൠ㺘䶒кDŽ䈧֯⭘ሬ
⭥⌑⋛ෛ˄㤕ᴹ˅ˈн㾱֯⭘ѫᶯव㻵DŽ䈧यሶѫᶯ൘ԫօ㺘䶒к━ࣘDŽ



ަԆড䲙

ᴯᦒ⭥⊐


⌘᜿һ亩
н↓⺞ᴯᦒ⭥⊐ਟ㜭ሬ㠤⠶⛨ড䲙DŽᴯᦒ⭥⊐ᰦˈ䈧ਚ֯⭘䇮༷⭏ӗ୶᧘㦀֯⭘Ⲵ⭥⊐DŽ
䈧᤹ᖃൠ⌅㿴༴㖞⭥⊐DŽ
䈧यሩ⭥⊐‫⭥ݵ‬DŽ䈧य᣶নǃࡪクᡆԕ
ަԆᯩᔿᦏൿ⭥⊐DŽ

ߧত઼≄⍱


⌘᜿һ亩
᤹➗䈤᰾ሿᗳᐳ㖞㓯㔶ˈቭ䟿߿ቁ≄⍱䱫ຎ઼ߧত䰞仈DŽѪ‫؍‬䇱䘲ᖃⲴߧত઼≄⍱ˈ䘀㹼㌫
㔏ᰦ䈧⺞‫؍‬ᵪ㇡ⴆᐢᆹ㻵DŽᵚᆹ㻵ᵪ㇡ⴆণ䘀㹼㌫㔏ਟ㜭ሬ
㠤㌫㔏䜘ԦਇᦏDŽᆹ㻵ᵪ㇡ⴆⲴ↕僔ྲл˖
俆‫ݸ‬Ựḕᒦ⺞‫؍‬㌫㔏޵⋑ᴹ䚇⮉Ⲵᵚപᇊᐕާᡆ䜘ԦDŽ
Ựḕ㓯㔶ǃ޵ᨂᶯ઼ަԆ㓴Ԧᐢ↓⺞ᆹ㻵DŽ
᤹ӗ૱䈤᰾ᆹ㻵ᵪ㇡ⴆDŽ


ProxySG Quick Start Guide 69


Appendix B: Safety Notices

General System Cautions


To ensure normal operation, follow these guidelines:
• Top cover removal: Before removing the top cover, turn off the power.
• Ventilation guidelines: Do not block any openings in the system to avoid overheating the appliance.
• Water caution: Do not get any water on the appliance.
• System use and installation: Except for the compact ProxySG 210 models, ProxySG appliances are intended for use in a server room
only. It is not intended be installed in individual employee work areas.

Warnings and Compliance Statements

Class A Digital Warning


This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ-
ment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction
manual, might cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the users are required to correct the interference at their own expense.

Advertencia Digital Clase A


Este equipo ha sido probado y se ha visto que se mantiene dentro de los límites de un dispositivo digital Clase A según la parte 15 de las normas
de la FCC. Estos límites están designados para proveer una protección razonable contra interferencias dañinas cuando el equipo es usado en
un ambiente comercial. Este equipo genera, usa y puede irradiar energía de radiofrecuencia; si no es instalado y usado de acuerdo al manual
de instrucciones, puede causar interferencias perjudiciales para las comunicaciones de radio. El uso de este equipo en un área residencial puede
causar interferencia perjudicial; en este caso los usuarios deberán corregir la interferencia cubriendo los gastos por ellos mismos.

EC Community EMC Warning


This is a Class A product. In a domestic environment, this product might cause radio interference in which case the user might be required to
take adequate measures.

Advertencia EMC de la Comunidad EC


Este es un producto Clase A En un ambiente doméstico, este producto puede causar interferencia de radio, en cuyo caso el usuario podría verse
obligado a tomar medidas adecuadas.

Canadian EC EMC Warning


This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la class A est conforme a la norme NMB-003 du
Canada.

Australia/New Zealand EMC Warning


This is a Class A product. In a domestic environment, this product might cause radio interference, in which case the user might be required to
take adequate measures.

70 ProxySG Quick Start Guide


Appendix B: Safety Notices

Taiwan BSMI Notification

Japan VCCI EMC Notification

Korea RRL Notification

China CCC Notification

ProxySG Quick Start Guide 71


Appendix B: Safety Notices

72 ProxySG Quick Start Guide


Appendix B: Safety Notices

ProxySG Quick Start Guide 73


Appendix B: Safety Notices

74 ProxySG Quick Start Guide