You are on page 1of 1

Volumetric infusion pump

Model
OPTIMA VS
Optimal I.V. therapy:
Optima VS is a volumetric pump, well suited to any care
unit, that focuses on essentials: security and easy of use.
Optima VS uses a second generation peristaltic pumping
system that offers cost effective solutions for large volume
infusion and drug delivery.
Optima VS offers an extensive range of settings modes to
meet all infusion protocols: from the simplest to the most
specific.

Performances Flow rate range § 1 to 1000 ml/h in normal mode (1 ml/h increments).
§ 0.1 to 100 ml/h in micro-infusion mode (0.1 ml/h increments).
Flow rate accuracy + 5% with recommended sets.
Volume range § 1 to 9999 ml in normal mode (1 ml increments).
§ 0.1 to 999.9 ml in micro-infusion mode (0.1 ml increments).
Infusion time adjustable from 1 minute to 96 hours (1 min. increments).
Setting modes flow rate only, flow rate + volume, volume / time, rate + time, ramp up/ramp down, primary/secondary,
sequential, bolus, induction/loading dose, micro-infusion.
OCS (Occlusivity Check the patented OCS test is the only auto-test to check the good operating of pump in association with its
System) set thus preventing all risk of free flow.
KVO rate 3 ml/h, adjustable.
Pressure limit 750 mmHg, adjustable from 100 to 900 mmHg (50 mmHg increments).
Pause function adjustable from 1 minute to 24 hours.
History module up to 750 last dated events.
Configuration infusion modes (micro or macro-infusion), ramp up/ramp down, sequential, induction, bolus, primary
/secondary, keyboard lock, KVO, pressure limit, display of drug name, time and hour setting,
language, LCD contrast, alarm sound level, ward name, maximum authorised flow rate, air bubble
size, recall of last parameters at power ON, display mode, volume cumulating, end of infusion pre-
alarm setting.
RS 232 connection bi-directional connection
Nurse call outlet for alarm report.
Safety features and Alarms § air detection: set at 250 µl over the last 15 minutes, adjustable.
§ protections against free flow: check of pump + set occlusivity (OCS test), automatic clamping
of the set at door openning.
§ check of line: OCS test, door open, set positioning, set installation, downstream occlusion,
upstream occlusion, line disconnection.
§ check of infusion: End of infusion warning, end of infusion, empty container, flow error,
unconfirmed setting, end of pause.
§ check of device: OCS test, door open, mains power disconnection, low battery, discharged
battery, technical fault, auto-test, motor rotation.
§ detection of occlusions: downstream and upstream.
§ DPS (Dynamic Pressure System): detection of pressure variations in the line (increase, drop)
allowing both a faster occlusion detection or a line disconnection.
§ anti-bolus system: automatic bolus reduction at occlusion release.
§ keyboard lock: protection against change of settings, function available in configuration.

Technical Pumping system second generation linear wave peristaltic pumping system controlled by an inteligent software for a
specifications constant and precise flow rate.
Pump fixation the Optima VS can be placed onto a table, or secured to a pole or to a rail with the incorporated
clamp.
Compliance complies with the 93/42 EEC: European Medical Device Directive CE 0459.
complies with EN 60601-1 and EN 60601-2-24 requirements.
§ waterproofness: protection against splashing liquid IP31.
§ protection against leakage current: type CF equipment .
§ protection against electrical shocks: class I equipment.
Mains supply 100-240 V ~ / 50-60 Hz.
Battery characteristics: NiMH – 6 V 2.7/3 Ah.
battery life: 5 h 30 in average at 125 ml/h.
Battery charging time device off: 5 hours / Device on: 16 hours.
Drop detector use in option for an empty bottle detection.
Housing in PC ABS HF, the unit is designed to reduce liquid ingress and facilitate the cleaning and
disinfection.
Dimensions (cm) / Weight H=13,5, W=17,5, D=14,5 cm / 2,9 kg.

TECHNICAL SHEET - FRESENIUS VIAL CATALOG 2003 - 0432 rev 6 - 06/01/03