PARAMETERS OF OHE

CONDUCTORS

1
2
TYPES OF OHE

3
MESSENGER WIRE

The Messenger wire shall be of Cadmium


copper, diameter 10.5 mm, consisting of 19
strands, each of 2.1 mm diameter. The nominal
cross section of the Messenger wire is 65 sq.
mm. The messenger wire shall conform to Indian
Railways' RDSO specification No. ETI/OHE/50
(Latest Revision).

4
SALIENT FEATURES OF THE MESSENGER WIRE

• Breaking Load 3920 kgf

• Coefficient of linear
Expansion (α) 17 x 10-6 degree C

• Elongation factor (λ) 118 x 10-6

• Conductivity 81%

• Resistivity 2.93 microhms. cm

5
Contact Wire 107 mm2

The contact wire shall be of 107 sq. mm


hard drawn grooved copper conductor,
diameter 12.24 mm. The contact wire
should be drawn out of continuous cast
rods of minimum diameter of 21mm. The
contact wire shall conform to UIC
specification UIC 870-0/latest RDSO
specification

6
Contact Wire Round Bottom

7
SALIENT FEATURES OF 107 SQ.MM CONTACT
WIRE

• Linear weight 0.9512 kg/ metre


• Breaking load 3905 kgf
• Coefficient of linear
Expansion (α) 17 x 10-6degree C
• Elongation factor (λ ) 91 x 10-6
• Conductivity 98%
• Resistivity 1.777 microhm. cm

8
CONTACT WIRE 150 SQ.MM

The contact wire shall be of 150 sq


mm hard drawn grooved, flat bottom
copper conductor, diameter 13.8 mm.
The contact wire should be drawn out
of continuous cast rods of minimum
diameter of 21 mm. Contact wire shall
conform to UIC specification UIC 870-
0/latest RDSO specification.

9
Profile of Contact Wire

10
SALIENT FEATURES OF THE CONTACT WIRE 150 mm2

• Linear weight 1.340 kg/ metre


• Breaking load 5369 kgf
• Coefficient of linear
Expansion (α) 17 x 10-6degree C
• Elongation factor (λ ) 91 x 10-6
• Conductivity 98%
• Resistivity 1.7593 microhm. cm

11
RETURN CONDUCTOR

All aluminium conductor (SPIDER) consisting of


19 strands each of 3.99 mm diameter, with a
nominal cross section of 233 sq.mm and a
copper equivalent of 140 sq.mm is used as
Return Conductors.
The overall diameter of conductor is 19.9 mm.
The SPIDER conductor shall conform to Bureau
of Indian Standards, specification IS:398(Part I)-
Latest Revision.

12
SALIENT FEATURES OF
SPIDER RETURN CONDUCTOR

• Linear weight 0.652 kg/metre


• Breaking Load 3736 kgf
• Coefficient of linear
Expansion (α) 23 x 10-6degree C
• Conductivity 60%
• Resistivity 2.8356 microhms.cm

13
OVERHEAD PROTECTION CABLE

• Linear weight 0.437 kg/metre


• Breaking Load … 4610 kgf
• Coefficient of linear
• Expansion (α) 18 x 10-6 degree C
• Elongation factor (λ) 132 x 10-6
• Conductivity 61% of aluminium
• Resistivity 2.8264 microhms.cm

14
FEEDER WIRE
The following two sizes of feeders will be used, as
required, on the Overhead Catenary System.

• 145 sq mm feeder of Electrolytic copper, consisting of


37 strands, each of 2.24mm diameter, with a nominal
cross section of 145 sq mm and diameter of 15.7mm.

• 262 sq mm feeder of Electrolytic copper, consisting of


37 strands each of 3.0mm diameter, with a nominal
cross section of 262 sq mm and diameter of 21.0 mm.

15
JUMPERS

Three sizes of jumper wires will be used in the OHE .

16
1. 164 sq mm jumper of annealed copper,
consisting of 37 strands each strand
containing 7 wires each of 0.9 mm diameter,
with a nominal cross section of 164 sq mm
and diameter of 18.1 mm.

• Usage

 Continuity Jumpers
 Feeder Jumpers
 Isolator Jumper

17
Continuity Jumper

18
2. 75 sq mm jumper of annealed copper,
consisting of 37 strands each containing 7
wires each of 0.6 mm diameter, with a
nominal cross section of 75 sq mm and
diameter of 12.70 mm. This is used as
Continuity Jumper.

Usage
 Continuity Jumpers
 Feeder Jumpers
 Isolator Jumpers

19
3. 26 sq mm jumper of annealed copper,
consisting of 19 strands, each strand
containing 7 wires each of 0.5 mm diameter,
with a nominal Cross Section of 26 sq mm
and diameter of 7.5 mm. This is used as In-
span jumper.

Usage
 In span Jumpers
 Potential Equalizer Jumper

JUMPER 20
In-span Jumper

21
22
Bridle wire
• Bridle wire shall be of cadmium copper, consisting of 37
strands each of 1.1mm diameter with a nominal cross
section of 35 sq. mm and overall diameter of 7.7 mm.
The Bridle Wire shall conform to Indian Railway's RDSO
specification ETI/OHE/50, Latest version, for cadmium
copper conductor.

USAGE

 Tramway OHE

23
Tramway cantilever with Bridle wire

24
Droppers
• The contact wire is suspended from the messenger wire
by means of droppers made of bronze. In addition, the
Register arm of the cantilever assembly is supported
from the bracket tube by means of a stainless steel
dropper. The following are the details of the droppers
used.

 Span Droppers

 Wind Stay Dropper

25
SPAN DROPPERS

• Flexible droppers, made of bronze, consisting of


1 wire of 7 strands each of 0.65 mm diameter
and 6 wires of 7 strands each of 0.54 mm
diameter, with crimped endings with eye on
either end and reinforced automatic clamps
(copper alloy made) on messenger wire and
contact wire, are used as in-span droppers. The
nominal cross sectional area of the droppers is
12 sq. mm and the diameter is 5 mm.

26
Span dropper

27
Wind Stay Dropper

Flexible stainless steel wire, 5 mm


diameter and 19.6 sq. mm cross section
with crimped ending eyes and fixing parts
on either end, will be used as Register arm
dropper

28
Windstay Dropper

29
Buried Earth Conductor (BEC)

BEC shall be made of flexible copper conductor


consisting of 7 strands each of 2.5 mm diameter.
The nominal cross sectional area is 35 sq mm
and the overall diameter is 7.5 mm. The BEC
shall conform to Indian Railway's RDSO
specification for "Annealed stranded copper
conductors" (ETI/OHE/3, Latest version) and IS:
9968 (Part 2).

30
Buried Earth Conductor (BEC)
• In Phase – I Corridors Copper Buried
Earth Conductor has been used for equi-
potential connections of all
Reinforcements embedded in the viaduct.

• In Phase – II corridors 93.3 Sq. mm


ACSR conductor which is same as Over
Head Protection Conductor has been
adopted.
31
HEIGHT OF CONTACT WIRE

Elevated Corridors

 Main Lines 5000 mm from HRL

 Depots 5200 mm from HRL

 Gradient of Contact
wire 3 mm / meter

32
Height of contact wire

Underground Corridors

Main Lines 4318 mm from HRL

Depots are constructed ‘At Grade’

33
Thank You