170 80 2,200 80 170 NOTES

1) All dimensions are in millimeters unless otherwise stated


2) All levels in meters above sea level
170 80 2,200 80 170 3) Structural details are not included
4) All structural concrete is class 25/10mmagg
5) All mass concrete is class 15/10mmagg

Metallic tank cover Water inlet filter


600 300
Metallic tank cover Water inlet filter

500

400
600 300

500

400

Do
wn
pip
e
Downp
ipe

System
Guttering
Guttering
System

CLIENT:

THE REPUBLIC OF UGANDA:

MINISTRY OF WATER AND ENVIRONMENT


DIRECTORATE OF WATER DEVELOPMENT

FINANCED BY: IN ASSOCIATION WITH :

Plan 005
6m length gutter fixed on fascia board
300x400 water inlet filter
4" Breather GOVERNMENT OF UGANDA: AFRICAN DEVELOPMENT
500x600 metallic tank cover BANK:

300 PROJECT:
CONSTRUCTION OF HOUSEHOLD AND COMMUNAL RAIN WATER
HARVESTING FACILITIES IN THE DISTRICTS OF APAC,BUDUDA,
KATAKWI AND OTUKE
2,200
2,000

CONSULTANT:
WSS SERVICES (U) LTD

Horizontal BRC mesh PLOT 17, KAKUNGULU ROAD,Building B


joined with vertical BRC 300x300x150mm concrete fotting
Ministers village, Village 9
250

Ntinda, Kampala,

750 P.O.Box 27755 Kampala Uganda.


250

Section 005 CONTRACTOR:


Tel:+256 772488074, +256 782519315

BANA ENTERPRISES LTD

P.O. Box 8935, Kampala - Uganda


Tel: 0772471156

Guttering Sytem

First flush system 300


DRAWING NO.
005
2,200
DRAWING TITLE:

AS BUILT DRAWINGS:
Household Tanks 8CM built in
2,000

Ongongoja, Usuk and Katakwi


Subcounties in Katakwi District

SCALE:
As shown

Drawn By:

Elevation 005 Designed By:

Surveyed By:

CHECKED BY:

APPROVED BY:

FERROCEMENT TANKS BUILT IN ONGONGOJA, USUK & KATAKWI SUBCOUNTIES


DATE:
CAPACITY LAYOUT QTY BASE CONSTRUCTION WALL AND ROOF INTERCONNECTION
30th/11/2018
SINGLE 120 DIAMETER HEIGHT ABOVE HEIGHT BELOW DIAMETER HEIGHT(mm) THICKNESS
8CM GROUND LEVEL GROUND LEVEL
(mm) (mm) (mm)
(mm) (mm)

GSPublisherVersion 0.14.100.100 2500mm 0 0 2200mm 2000mm 80mm 0