FRIOCELL 22

cooled incubation in new volume of 22 l

… soft and silent incubation


… even homogen conditions
… minimum space and power consumption

• new chamber construction with single • new ergonomic door opening


jacket
Ideal for:
• interface RS 232 for connecting PC
• outer width only 41 cm or printer for process documentation • laboratories
– fits to each table, capacity up to • microbiological laboratories
• easy handling due to lightweight
4 racks, load capacity approx. 30 kg
construction • pharma, food & cosmetics
• high termohomogenity thanks to industry
• available with comfort controller,
unique air convection system
including 6 programs, 40 segments, • research in schools
• with advanced control automatics, real time, configurable temp. alarms
consistently meeting highest and chip card reader
and universities
requirements to quality, speed, simple
• broad range of original optional
operation and safety
equipment and accessories
• soft and silent Peltier system ensures
• high production quality
efficient cooling and heating with
minimum power consumption
• interior of high-quality stainless steel
DIN 1.4301 (AISI 304)

protecting human health


8898 MMM FrioCell 22P_EN.indd 1 22.8.2007 8:35:29
Options Technical data
Inner dimensions volume l
22
22
1) access ports ∅ 22, 50 mm Chamber, stainless steel width mm 244
depth mm 307
2) measurement of material´s temperature height mm 296
with an independent movable senzor PT 100 Volume of the steam space l 43
(with indication on display or PC) Trays, stainless steel *) number max./usual 4/2
Min. distance between trays mm 60
3) mechanical door lock with a key Storage area (w x d) mm 185x265
4) communication software WarmComm 3 Number of outer metal doors No. 1
Number of inner glass doors No. 1
5) external printer for chamber data recording Admissible weight of trays together inside the oven kg 25
per 1 tray kg 10
1 Electricity data max. power W 100
consumption
mains 50/60 Hz V 100–240
Protective system IP 20
Temperature data
Working temperature from 0 °C to °C +5 °C – +70 °C
Temperature accuracy
in space at 10 °C ± °C < 0,3
at 37 °C ± °C < 0,3
2 in time ± °C < 0,1
Heating/up time to 37 °C min < 10
from the ambient temperature
Cooling/down time from 22 °C min < 33
to 10 °C
Recovery time after at 37 °C min 1,5
1 min. door open at 50 °C min 4
Heat emission at 37 °C W 50
Outer dimensions (incl. door width max. mm 406
3 and handle, Feet or Rollers) depth max. mm 592
height max. mm 605F
Weight net kg 33
gross kg 38

MMM Medcenter Einrichtungen GmbH Friocell 22 P – EN/8898 08/2007