Professional Documents
Culture Documents
Directory
Overview …………………………………………1
Working principle … … … … … … … … … … … … … … 1
Dimensions … … … … … … … … … … … … … … … … 1
Work Environment … … … … … … … … … … … … … … 2
Wiring… … … … … … … … … … … … … … … … … … 2
Operation… … … … … … … … … … … … … … … … … 4
Overview
HCYD22 elevator emergency power supply device is a power failure
stop running for the elevator, through inverter power supply to the
elevator rescue a safety device automatically. Mains normal standby mode
when the device is detected, when the mains power failure or phase,
equipment delayed start, through pre -tuned inverter lowest frequency, low
traction elevator to the floor leveling position, open the elevator door,
ensure that passengers safe to leave the el evator.
Working principle
This device is always monitoring the presence or absence of the mains, there is
electricity in the case the device is not put into operation. When the power cut, means to
lift a start signal, the output of two-phase AC220V AC delay, this time to adjust your speed
to move the elevator to leveling, open the elevator door.
Specific action sequence is as follows: When a mains, device HC - TDGK board
LED1, LED5, LED9 normally on, KY do, LED2 flashing, device detecting mains.
When power outage LED4 bright immediately, LED6 normally on, KY disconnect,
LED1, LED5, LED9 out; LED11 after 15 seconds LED12, LED15 bright, bright; 28
seconds after LED13, LED16 bright, device output, output terminals on L2, N2 AC220V
voltage, LED14 bright 33 seconds.
When the device terminals output AC220V voltage at L2, N2, device to stop output,
after the completion of the work, the device to exit.
Device from the connector KKA output enable signal on 1, 2, 3, 4 sub phase sequence
relay in elevator control cabinet.
If the device operates incoming call, the device will exit.
Dimensions
Dimensions( L × W × H): 3 40 *2 65 *1 60 mm
—— 1 ——
HCYD 电梯停电应急供电装置
3、 air shall not contain explosive, corrosive and other harmful gases or dust.
Wiring
1、 Cable Connection
Means all signal lines are output from the connector, KKA -1, KKA-2 as an
emergency run signal; KKA -3, KKA-4 for connecting elevator phase
—— 2 ——
HCYD 电梯停电应急供电装置
Plug-number Features
12 11 10 9 8 7
KKA-1 Start signal
6 5 4 3 2 1
KKA-2 Start signal
Te r m i n a l b l o c k
Features
number
PE PE
L1 Power input
N1 Power input
L2 Power output PE L1 N1 L2 N2
N2 Power output
—— 3 ——
HCYD 电梯停电应急供电装置
Internal table
Operating
—— 4 ——
HCYD 电梯停电应急供电装置
Contactor KY: KY contactor has three normally open a normally closed contacts, normally open
three-phase electric control cabinet is isolated;
Troubleshooting
The device is maintenance-free, with automatic discharge function. Recommended a trial is
conducted quarterly to measure FA and whether there is between 0V and 24V DC voltage, in order to
ensure proper functioning of equipment.