You are on page 1of 18

RIMS MEDICAL COLLEGE- CDP122

T/F Capacity Cable size


S.NO Building Name Square feeder Building Height
in KVA in Sqmm
1 RIMS MEDICAL COLLEGE 500 400A MCCB, BUSBAR 300 15

RIMS MEDICAL COLLEGE- CDP114


2 RIMS HOSPITAL- OP BLOCK 500 630 A MCCB, BUSBAR 300 15

3 RIMS HOSPITAL- IP BLOCK 500 630A MCCB, BUSBAR 300 15


Latitude and Longitude DG Details in KVA

14.433072, 78.866233 125

14.433172, 78.864548 NA

14.433323, 78.863045 NA
GGH Ananthapuram HT BILL NO- ATP057

T/F Capacity DG Capacity in Cable size


S.NO Building Name Rating of LT panel
in KVA KVA in Sqmm
1 Old Block 630 A,400 A 95

250 A, 250 A, Spares-


2 OP & Pediotic Block 120
500 125A(3 Nos) 125A

3 Ortho Block 400 A 95


4 Emergency Block Under construction 95

Remarks:
1. Main control room LT panel to over head line 95sqmm cable terminated around 25mtr open cable.
2. 415v transmission line running around over all hospital, they tapped from line to building LT panels.
3. trees trimmimg required
4. wherever Pillers there we need to take permission from client to install our solar plant
5. Ortho Block & old building very old LT panles
6. Emergency Block LT panels installation under construction

Note:
Above information taken from as per present site condition & Electrician
Latitude and Longitude Remarks

14.6715509, 77.5959243

14.6709891, 77.5948705

14.6707432, 77.5945660
14.6714960, 77.5947870

pen cable.
g LT panels.
GGH Machilipatnam HT BILL NO- VJA594

T/F Capacity DG Capacity in Cable size


S.NO Building Name Rating of LT panel
in KVA KVA in Sqmm
250A - 2no.s,
1 Gynic & Children Block 300, 120
125A(3no.s) - spares
315 250
2 OP Block 125A 35

3 General Wards 315 125A 160 35

Remarks:
1. Gynic & Childern Block LT panles is placed at MCH block
2. some buildings client didn’t aloowed to do suvery due to building extensions
3. Trees trimming required
4. OP Block & General wards there is no proper LT panels.
5. 415v transmission line running around Op Block & general wards, they tapped from line to building 125A switchs.
6
Latitude and Longitude Remarks

16.1774400, 81.1375623

16.1774030, 81.1387365

16.1764232, 81.1386258

to building 125A switchs.


GGH Vijayawada HT BILL NO- VJA757

T/F Capacity DG Capacity in Cable size


S.NO Building Name Rating of LT panel
in KVA KVA in Sqmm
1 Diagnostic Block 315 400 A, 250A- 2nos 250 240

2 OPD Block 315 400 A- 2 nos 125 240

3 Casuality Block 315 400 A- 2 nos 125 240


Latitude and Longitude Remarks

16.5170622, 80.6700295

16.5163990, 80.6696426

16.5166896, 80.6698675
Government Medical College, Ananthapuram HT BILL NO- ATP291

T/F Capacity DG Capacity in Cable size


S.NO Building Name Rating of LT panel
in KVA KVA in Sqmm

1 Govt Medical college 315 400 A 63 240


Latitude and Longitude Remarks

16.5170622, 80.6700295
Dr.NTR University of Health Sciences, Vijayawada HT BILL NO- VJA656

T/F Capacity DG Capacity in Cable size


S.NO Building Name Rating of LT panel
in KVA KVA in Sqmm

Dr.NTR University of health


1 500 630 125 95
sciences
Latitude and Longitude Remarks

16.5166607, 80.6690887
Siddharth Medical college, Vijayawada LT BILL NO- 6511300003703

T/F Capacity DG Capacity in Cable size


S.NO Building Name Rating of LT panel
in KVA KVA in Sqmm

1 Siddarth medical college 500 630 125 240


Latitude and Longitude Remarks

16.5183380, 80.6710152
SKU HT BILL NO- ATP007

T/F Capacity Cable size Building Height Access to


S.NO Building Name Square feeder
in KVA in Sqmm roof
1 Chemistry 200 A fuse 70 13.3 No access

2 USIC 160 10 Stair case

2 Science Block- III 100 A fuse, Bus bar 50 12.6 Ladder


200 A fuse, 125A
3 Bio science 160 70, 50 12.5 Stair case
switch, Busbar
4 Law 100 A fuse 35 8.4 Ladder

5 Arts 100 A fuse, Bus bar 35 No access

6 Science Block IV 160 100A Switch 6 8 Ladder

7 Kaleswari Bhawan 250 A switch, Busbar 70 11 Stair case

8 Pharma ceutical science 160 200 A Switch, Busbar 70 8.7 Stair case

9 Atal incubation center 250 A switch, Busbar 35 9 Stair case

SKU LT BILL NO- 7123108000360


10 Examination Block 100 A fuse, Busbar 35 8.85 Stair case

160
11 Administrative Block 100 A fuse 50 9 Stair case
Latitude and Longitude Remarks Common Point

14.610766, 77.646539 No access to roof


Building jointly connected with
chemistry Block,we can terminate in
14.610851, 77.646813 chemistry block, Trees should be
trim
14.612135, 77.646787

14.611891, 77.645284

14.6131670, 77.6439083
Didn’t take roof dimensions due to
no access to roof
1. Over all Campus
Transmission Line
cable fully burnt, here they placed from Main
14.613181, 77.645469 connected 6 sqmm cables to LT control room. For
panel mains from Over head line each Buiding they
tapped from TL to LT
Panel
14.614799, 77.645415 2. Water proofing
3inch
14.613898, 77.646613 Obstacles like Pillars, Head room

Obstacles like Pillars, Head room, old


14.612590, 77.646992 solar panels

Obstacles like pillars, Head rooms,


14.607873, 77.653716 Old solar panels
Obstacles like pillars, Head rooms,
14.605594,77.653943 10KW Old solar panels covered by
roof
ACSR Medical College, Nellore - HT no. NLR760

T/F Capacity Rating of LT panel Rating of LT panel (4th


S.NO Building Name in KVA (Ground Floor) floor)

1 ACSR Medical College 500 - 2 no.s 400A 250A


760

DG Capacity in Cable size Latitude and Longitude Remarks


KVA in Sqmm

250 240