Belt conveyor drive unit. mk2 values (kgm2). Average.


1500
Ref Voith
rpm sq. Motor mk2 Input coupling mk2. Any mk2 output
Gear box mk2 fluid
motor (Siemens) one of the following coupling
coupling
kW
Flex Fluid More Ratio
Upto Ratio more
Flex + Fluid + than 18: upto
18: 1 than 18: 1
drum drum 1 18: 1
11 0.055 0.035 0.06 0.0025 0.0014 0.125 0.125 274D

15 0.065 0.035 0.06 0.0027 0.0014 0.125 0.125 274D

18.5 0.13 0.035 0.06 0.215 0.24 0.003 0.0026 0.250 0.250 274D or 366

22 0.15 0.035 0.10 0.215 0.275 0.0033 0.0037 0.250 0.500 366

30 0.24 0.035 0.10 0.215 0.275 0.005 0.0044 0.250 0.500 366

37 0.478 0.035 0.10 0.42 0.48 0.006 0.008 0.50 0.500 422

45 0.54 0.035 0.10 0.42 0.48 0.010 0.015 0.50 0.50 422

55 0.80 0.035 0.18 0.42 0.57 0.010 0.015 0.50 0.75 422

75 1.375 0.050 0.18 0.42 0.57 0.019 0.025 0.75 1.30 422 or 487

90 1.60 0.050 0.35 1.00 1.30 0.035 0.046 1.30 2.15 487

110 2.20 0.12 0.35 1.00 1.30 0.056 0.046 1.30 2.15 487

132 2.70 0.12 0.50 1.00 1.30 0.056 0.081 1.30 3.75 487

160LT 3.20 0.12 0.75 2.10 2.70 0.100 0.081 2.15 3.75 562

200LT 4.20 0.12 0.75 2.10 2.70 0.110 0.136 2.15 7.50 562

250LT 6.00 0.24 1.37 2.10 3.20 0.185 0.257 3.75 7.50 562

315LT 7.40 0.24 1.37 4.40 5.50 0.310 0.257 7.50 7.50 650

400HT 3.65 4.40 7.40 0.570 0.59 7.50 14.20 650

500HT 3.65 8.00 11.00 0.570 0.59 7.50 14.20 750

2.2 0.0048 0.01 0.00048 0

3.7 / 4.0 0.011 0.01 0.0011 0

5.5 0.018 0.018 0.0018 0

7.5 0.024 0.018 0.0024 0

Note: 1) These are average data for use in conveyor design program, for sufficiently reliable

result. One can use own specific data as per actual situation.

2) Fluid coupling value is primary side mk2 + secondary side mk2. This total is to be used as

program calculates it as an equivalent to 'secondary side + 15% of (primary side + motor).

Derivation of primary side mk2 of fluid coupling and secondary side mk 2 of fluid coupling from

given fluid coupling total mk2 and motor mk2.

Let P = Primary side mk2 of fluid coupling. Let S = Secondary side mk2 of fluid coupling.
Let F = Fluid couplng total mk2. Let M = Motor mk2.

So, as per first statement of this note, F = P + S ………. Equation - 1.

Also, as per second statement in this note, P + S = S + 0.15(P + M) ………. Equation - 2.

Cancelling 'S' from both sides of equation - 2 gives, P = 0.15(P + M). So, P = 0.15P + 0.15M.

Therefore, 0.85P = 0.15M. Therefore, P = 0.1765M … Answer - 1 (to be used always).

Substituting answer - 1 in equation - 1 gives, F = 0.1765M + S ……….Equation - 3.

Solving equation - 3 further gives, S = F - 0.1765M … Answer - 2 (to be used always).

3) mk2 = GD2 ÷ 4