You are on page 1of 2

ACCUMULATOR SKID Inspection Report - NPCC Yard, Abu Dhabi

BI NO.
BI-10-01263, 10- PO No: 7243-2017/57300-AC INSPECTION LEVEL: LEVEL 3 PLANT ID:
02015 & 10-02016 Equipment Tag: G62-8K-CP-009 Manufacturer: SAWDIWELLS SFNY TP-
ARAMCO DUMMY PO NO: CNI- 21
9COM NO:
385-34(1)-C140-DA

Item Required For


Item Description Reference Skid Photographs Discipline Category Degree Remarks
No. Start-Up

Findings: Coating peal off and damages on skid frame.


Requirements: The dry film shall be free of any application
1 related defects such as but not limited to runs, sags, drips, dry SAES-H-004 Para 9.4.5 Coating No Violation Minor
spray or foreign matter. Any defects shall be repaired and re-
tested for assurance. SAES-H-004 Para 9.4.5

Findings: Coating runs, drops & sags on skid frame.


Requirements: The dry film shall be free of any application
2 SAES-H-004 Para 9.4.5 Coating No Violation Minor
related defects such as but not limited to runs, sags, drips, dry
spray or foreign matter. The dry film shall be of Uniform
appearance.

Company General Use


ACCUMULATOR SKID Inspection Report - NPCC Yard, Abu Dhabi
BI NO.
BI-10-01263, 10- PO No: 7243-2017/57300-AC INSPECTION LEVEL: LEVEL 3 PLANT ID:
02015 & 10-02016 Equipment Tag: G62-8K-CP-009 Manufacturer: SAWDIWELLS SFNY TP-
ARAMCO DUMMY PO NO: CNI- 21
9COM NO:
385-34(1)-C140-DA

Item Required For


Item Description Reference Skid Photographs Discipline Category Degree Remarks
No. Start-Up

Findings: Coating damage on Accumulator cylinders and frame


due to covering in wet condition with bubble wrap
3 Requirements: The dry film shall be free of any application SAES-H-004 Para 9.4.5 Coating No Violation Minor
related defects such as but not limited to runs, sags, drips, dry
spray or foreign matter.SAES-H-004 Para 9.4.5

Findings: Coating film burns & improper repair on Accumulator


cylinders.
Requirements: The dry film shall be free of any application
related defects such as but not limited to runs, sags, drips, dry
4 SAES-H-004 Para 9.4.5 & 9.5 Coating No Violation Minor
spray or foreign matter,Cover all coated areas near to the
defective area before commence repair or patching up. Use
heavy duty textile or fabric adhesive tape. SAES-H-004 Para 9.4.5
& 9.5

Company General Use