You are on page 1of 216

COMPANY INFORMATION

////
PRODUCT
////
CATEGORY
*
SECTION
PAGE 1

INTRODUCTION
Dulhunty Power is a manufacturer and supplier of quality Electricity Transmission and Distribution products. The company has manufacturing
plants in Sydney (Australia),Yangzhou (China) Bangkok (Thailand) and Darul Ehsan (Malaysia), as well as sales offices in New Zealand and
Hong Kong.

The company supplies its own products to utilities and contractors throughout Australia, New Zealand, China, and the Asia Pacific region. It also
supplies components and fittings for a number of European and American companies involved in the electricity transmission and distribution
sector.

Dulhunty Power is most well known for its range of vibration control products and its technical capability in measuring and resolving vibration
control problems in transmission line applications. The company has invested heavily in developing products and solutions for Aeolian vibration,
and is one of the foremost companies in this field in the world.

Apart from manufacturing and selling a large range of its own products, Dulhunty Power also represents a number of other manufacturers,
supplying products including glass, porcelain and composite insulators, substation fittings, fault indicators, height meters, tension monitoring
systems, switchgear, corona cameras, emergency tower structures, and high temperature conductors.

Dulhunty Power arose from the merger of Dulhunty Industries Pty. Ltd., founded by industry veteran Mr Philip Dulhunty, Dulhunty Engineering
Ltd., a Hong Kong-based company and Dulhunty Yangzhou Line Fittings Co. Ltd. (Philip Dulhunty was also the founder of
Dulmison more then 50 years ago).

The merger combined the technical and marketing capacity of the Australian company with the low cost manufacturing of the Chinese company,
and has opened new markets for both. In its first year of operations, the new Dulhunty Power has greatly expanded its horizons with sales from
Australia to Finland and from Morocco to the USA.
CATALOGUE SECTIONS

INDEX ////
////
CATEGORY

PRODUCT
A
SECTION
PAGE 2

Insulated systems Section A………………… Page 3 - 21


Protective fittings Section B ………………… Page 22 - 30
Line hardware Section C………………… Page 31 - 59
Helixon Section D ………………… Page 60 - 72
Strain and suspension clamps Section E………………… Page 73 - 81
Fabricated fittings Section F ………………… Page 82 - 95
Other products Section G …………………Page 96 - 151
Insulator pins Section H……...................Page 152 - 153
Insulators Section I………………… Page 154 - 188
High Temperature Conductors Section J…………………. Page 189 - 192
Conductor information Section K ………………… Page 193 - 208
Description index ……………………………………………………… Page 209 - 213
INSULATED SYSTEMS

INDEX ////
////
CATEGORY

PRODUCT
A
SECTION
PAGE 3

LV ABC Suspension Clamp Type ABCSC….………………… Page 4


Suspension Clamp and Rollers Type SO & ST............................ Page 5
LV ABC Tension Clamp Type ABCTC……………………..Page 6
LV ABC Service Clamp Type ABCTCS.…………………..Page 7
LV ABC Bolted Service Clamp Type ABCTC……………………..Page 8
Hook Bolt Type ABCHB……………………. Page 9
Weak Link Type ABCWL…………...…….. Page 9
Hook Nut & Eye Nut Type ABCHN & ABCEN….……. Page 10
Insulation Piercing Connectors Type ABCIPC………….….……..Page 11
Yoke Type ABCYB……………...…….. Page 12
Hook Brackets Type ABCHBR………….………. Page 13
Wedges Type ST & PMR………………….Page 14
HV ABC Termination Assembly Type …………………………….. Page 15
HV ABC Helixon Restraint Assembly Type HR………………………… Page 16
HV ABC Suspension Assembly Type SB & SHB………………… Page 17
HV ABC Suspension Bracket & Hook Bolt Type SB & SHB………………… Page 18
HV ABC Suspension Clamp Type ABCHV…………………… Page 19
HV ABC Roller and strap Type ………..…………………… Page 20
CCT Conductor Fittings Type CCT……………………….. Page 21
LV ABC SUSPENSION CLAMP
INSULATED SYSTEMS

////
PRODUCT
////
CATEGORY
A
SECTION
PAGE 4

The clamp is suitable for up to 30°line deviation.

The clamp bush design is split for ease of application.

Materials:
Hardware: Galvanized steel
Bush: EPDM

Catalogue Number Cable size sq mm AS3560


Galv. Stainless 2 3 4
Body Body Core Core Core
ABCSC-435 ABCSC-435S 50 50 35
ABCSC-450 ABCSC-450S – – 50

ABCSC-470 ABCSC-470S 95 – 70
ABCSC-495 ABCSC-495S – – 95
SUSPENSION CLAMP & EXTENSION ROLLERS
INSULATED SYSTEMS

////
////
CATEGORY

PRODUCT
A
SECTION
PAGE 5

Used for the installation and suspension of


the 4 core ABC cables from poles in straight
lines and at angles of up to 90 Deg with 4x25
sq mm and 4x50 sq mm cables or up to 60
Deg with 4x95 sq mm cables.

ST 26.99 extension rollers are used during


the installation when angles exceed 30
Degrees.

Catalogue Conductors Cable Weight Package


Number sq mm Dia mm g pcs

SO 99 4x(25-95) 18-38 950 10


ST 26.99 Extension rollers 18-38 2300 10
for SO 99
INSULATED SYSTEMS

LV ABC TENSION CLAMP ////


////
CATEGORY

PRODUCT
A
SECTION
PAGE 6

The strain clamps are designed to facilitate assembly


onto the cable and includes spring loaded wedges
and a wide area between the straps.
The wedge action of the clamp ensures maximum
holding strength.

Materials:
Wedges: Glass filled nylon
Hardware: Galvanized Steel
Straps: Aluminium

Catalogue Cable Size


Number sq mm
AS3560
ABCTC-2595 2 x 50 – 2 x 95

ABCTC-2550 4 x 25 – 4 x 50

ABCTC-5095 4 x 50 – 4 x 95

ABCTC-95150 4 x 95 – 4 x 150
INSULATED SYSTEMS

LV ABC SERVICE CLAMP ////


PRODUCT
////
CATEGORY
A
SECTION
PAGE 7

ABCTCS-235 These clamps are designed to facilitate


Service clamp service wire installation

Materials:
Glass filled nylon
RC-3
Roller clamp Straps: Stainless steel

ABCTCS-435
Service clamp

Description Catalogue Cable Size


Number sq mm
AS3560
Service strain clamp ABCTCS-435 2 and 4 core 6, 10,16 25 and 35 sqmm

Service strain clamp ABCTCS-235 2 core 6, 10,16 25 and 35 sqmm

Roller clamp RC-3 2 and 4 core 4 , 6, 10 sqmm

Roller clamp RC-4 4 core 16sqmm


INSULATED SYSTEMS

LV ABC BOLTED CLAMP ////


////
CATEGORY

PRODUCT
A
SECTION
PAGE 8

The bolted clamps are designed to facilitate


installation of service wire terminations

With its swivel blocks it can also be used as a


suspension clamp.

Materials:
Glass filled nylon
Straps: Stainless steel

Strain arrangement

Suspension arrangement

Description Catalogue Cable Size


Number sq mm
AS3560
Strain / Suspension clamp ABCTC-41035 2 and 4 core 10, 16, 25 and 35 sqmm
INSULATED SYSTEMS

HOOK BOLTS & WEAK LINKS ////


////
CATEGORY

PRODUCT
A
SECTION
PAGE 9

Suitable for low voltage aerial bundled cables.

Material:
Galvanized Steel Suitable for low voltage aerial
bundled cables.

Minimum failing load : 4kN

Catalogue Number Material:


Length Diameter (D) Diameter (D) Carbon Grade Galvanized Steel
(L) 16mm 20mm
mm
AS3766 AS3766
Catalogue Diameter Overall Material
250 ABCHB16-250 ABCHB20-250
Number Length Diameter
350 ABCHB16-350 ABCHB20-350 (mm) (mm) (mm)
450 ABCHB16-450 ABCHB20-450 ABCWL-4 38 100 10
INSULATED SYSTEMS ////
CATEGORY
A
A
HOOK NUTS & EYE NUTS ////
PRODUCT
SECTION
PAGE 10

Material: Galvanized Steel

Hook Failing Catalogue Thread Thread Eye Min.


Catalogue (dia.) Load Number Diameter Length (D) Failing
Number mm kN mm mm mm Load
AS3766 AS3766 AS3766 AS3766 AS3766 kN

ABCHN-12 16 12 ABCEN-16 16 30 12 44
ABCEN-20 20 40 16 70
ABCHN-24 20 24
ABCEN-2020 20 40 20 120
ABCEN-24 24 45 20 120
INSULATED SYSTEMS ////
CATEGORY
A
A
LV ABC INSULATION PIERCING CONNECTORS ////
PRODUCT
SECTION
PAGE 11

Catalogue Insulated mains Insulated branch Number of


Number Cable Cable Bolts
sq mm sq mm
ABCIPC-440 16 to 95 2 to 6 1
ABCIPC-441 25 to 95 6 to 35 1
ABCIPC-445 35 to 95 25 to 95 1
ABCIPC-446 50 to 150 50 to 150 2

Catalogue Bare mains Insulated branch Number of


Number Alu Cable Cable Bolts
Diameter mm sq mm
ABCIPC-470 3 to 9.5 6 to 35 1
ABCIPC-472 3 to 12.5 35 to 95 2
ABCIPC-475 9.5 to 15.8 50 to 150 2
INSULATED SYSTEMS ////
CATEGORY
A
A
YOKES ////
PRODUCT
SECTION
PAGE 12

The yoke bar is suitable for use with two of


the ABCSC style clamps on angle poles,
where the line angle deviates by more than
30°
B
Materials:
Galvanized Steel

A C

Catalogue Dimension, mm Min. Failing


Number A B C Load kN
AS3766
ABCYB-12 16 105 175 12
ABCYB-12A 16 130 300 12
INSULATED SYSTEMS ////
CATEGORY
A
A
HOOK BRACKETS ////
PRODUCT
SECTION
PAGE 13

The hook bracket can be fixed to concrete or steel poles


with stainless steel strapping.

The hook bracket can be fixed to wooden poles with


bolts or coach screws.
A
Materials:
Galvanized Steel

P/N ABCHBR-12

Catalogue (A) Hole Diameter Min. Failing


Number mm Centers of Load
mm Hook kN
mm AS3766
ABCHBR-12L 250 200 16 12
ABCHBR-12 200 150 16 12
INSULATED SYSTEMS ////
CATEGORY
A
A
WEDGES ////
PRODUCT
SECTION
PAGE 14

Catalogue Description Weight Package


Number g Pcs

ST 31 Two Plastic 100 10


Wedges

ST 192 One Plastic 140 10


Wedge

ST 200 Wooden 290 10


Wedge

During the installation of connectors the phase conductors of an insulated overhead cable can be separated by using wedges. The
wedge can also be used when installing suspension clamps. The wedges can be left on the cable even after the installation

Catalogue Conductors Weight Package


Number Max mm Sq g Pcs

PMR 87 4 x 95 20 50

PM 154 4 x 50 25 50
HV ABC TYPICAL TERMINATION ASSEMBLY
INSULATED SYSTEMS

////
////
CATEGORY

PRODUCT
A
SECTION
PAGE 15

Alternative Alternative Alternative


Hook Bracket Ball Hook Socket Thimble
or or or
Eye Bolt Ball Clevis Clevis Thimble Helixon deadend

Helixon deadend to suit catenary wire


Part Number
Metallic screened 7/2.00 ……….….….DE-S0600
Metallic screened 19/2.00 …………….DE-S0975
EB16-300 BC-70 CTHA-2600

Non metallic screened 7/5.00 ….……..DE-A1430C


Non metallic screened 19/3.65 ……….DE-A1750C

ABCHBR-12 BH-70-LS SOCT-70

Catalogue 11kV 22kV


Number Non Metallic Screened Non Metallic Screened
sqmm sqmm

HR35-50 35 & 50
Helixon HVABC Restraint
HR70 70 35

HR95 95 50

HR70-95 70 & 95

HR120-150 120 & 150

HR185 185

HR120-150L 120 & 150

HR185L 185
INSULATED SYSTEMS

HV ABC HELIXON RESTRAINT ////


////
CATEGORY

PRODUCT
A
SECTION
PAGE 16

Socket thimble

Helixon deadend
Helixon HVABC restraint

HVABC cable

The Helixon restraint is a preventative restraint


Catalogue 11kV 22kV designed to minimise bird caging
Number Non Metallic Non Metallic
Screened Screened Bird caging is caused by either gravity forces
pulling on the conductor or as a result of a fault
sq mm sq mm current.
HR35-50 35 & 50 Designs for Helixon restraints for metallic screened
HR70 70 35 cables are available on request

HR95 95 50
HR70-95 70 & 95
HR120-150 120 & 150
HR185 185
HR120-150L 120 & 150
HR185L 185
INSULATED SYSTEMS

HV ABC TYPICAL SUSPENSION ASSEMBLY ////


////
CATEGORY

PRODUCT
A
SECTION
PAGE 17

P/N SB10312 P/N SHB16200 ABCHV


Suspension Bracket Suspension Suspension clamp
Hook Bolt
INSULATED SYSTEMS

HV ABC SUSPENSION BRACKET AND HOOK BOLT ////


////
CATEGORY

PRODUCT
A
SECTION
PAGE 18

P/N SB10312
Suspension
Bracket

P/N
SHB16200
Suspension
Hook Bolt
INSULATED SYSTEMS

HV ABC SUSPENSION CLAMP ////


PRODUCT
////
CATEGORY
A
SECTION
PAGE 19

Catalogue 11kV 22kV 11kV 22kV


Number Metallic Metallic Non Metallic Non Metallic
Screened Screened Screened Screened
sqmm sqmm sqmm sqmm
ABCHVMSC-35 35
ABCHVMSC-50 50
ABCHVMSC-70 70 35
ABCHVMSC-95 95 & 120 50
ABCHVMSC-150 150 70 & 95
ABCHVMSC-185 185 120

ABCHVMSC-150L 150

ABCHVMSC-185L 185
This suspension clamp is suitable for use on High Voltage
ABCHVNMSC-35 35 & 50 ABC cables.
ABCHVNMSC-70 70
Whether the cables are metallic or non metallic Screened.
ABCHVNMSC-95 95 & 120 35 & 50
It is suitable for up to 45 degree line deviation
ABCHVNMSC-150 150 70
ABCHVNMSC-185 185 95 & 120
ABCHVNMSC-150L 150
ABCHVNMSC-185L 185
INSULATED SYSTEMS

HV ABC ROLLER ////


PRODUCT
////
CATEGORY
A
SECTION
PAGE 20

The Dulhunty Power HVABC roller makes stringing HVABC easy. With its unique design and ease of handling, adjusting the sag and
hanging the suspension clamps becomes simple

With the additional yoke bar, most of the stringing angles can be accomplished

CSR-YOKEBAR

CSR-HVABC RACHETSTRAP

Catalogue Approx. Catalogue Approx.


Number Weight Number Weight
kg kg
RATCHETSTRAP 1.3
CSR-HVABC 10.5

CSR-YOKEBAR 3.5
INSULATED SYSTEMS

CCT CONDUCTOR FITTINGS ////


////
CATEGORY

PRODUCT
A
SECTION
PAGE 21

CCT post insulator 11kV long CCT post insulator 11kV short CCT strain insulator 11kV
Part number CCT-145 Part number CCT-45 Part number CCT-STRAIN

CCT Strain cover


80 - 120 sqmm
Part number CCT-COVER
LINE FITTINGS

INDEX ////
////
CATEGORY

PRODUCT
B
SECTION
PAGE 22

PROTECTIVE FITTINGS SECTION B LINE HARDWARE SECTION C


Vibration Damper Type 4D………. Page 23 Chain Link Type CL………. Page 38
Twin Spacer Type S2………. Page 24 Socket Clevis Type SC……….Page 39
Twin Spacer-damper Type SD2…….. Page 25 Socket Tongue Type ST………. Page 40
Triple Spacer-damper Type SD3…….. Page 26 Twisted Eye Tongue Type TET…….. Page 41
Quad Spacer-damper Type SD4…….. Page 27
Ball Hook Long Shank Type BH……… Page 42
Six bundle spacer – damper Type SD6…….. Page 28
Spacer closing tool Type………….. Page 29 Ball Hook Short Shank Type BH……… Page 43
Cast Bar Spacer Type CBS……. Page 30 Tongue Hook Type TH……… Page 44
Socket Thimble Type SOCT….. Page 45
Clevis Thimble Type CTH……..Page 46
LINE HARDWARE SECTION C Aluminium Parallel Groove Clamps Type PGA……..Page 47
Bimetal Parallel Groove Clamps Type PGB……..Page 48
Anchor Shackle Type AS………. Page 31 Copper Parallel Groove Clamps Type PGC……. Page 49
Ball Eye Link Type BEL……...Page 32 Bimetal Service Clamps Type ASC……. Page 50
Ball Clevis Type BC……….Page 33 Bimetal Service Tee Type …………. Page 51
Clevis Tongue Type CT……….Page 34 Ku-lugs Type KU……….Page 52
Twisted Clevis Tongue Type TCT……. Page 35
Split Bolts Type SB………. Page 53
Socket Clevis Extension Link Type SCEL…… Page 36
Wire Rope Grips Type WRG…… Page 54
Ball Eye Extension Link Type BEEL…… Page 37 Gain Blocks Type GB……… Page 55
Compression deadends Type CDE……. Page 56 &58
Compression midspan Type CMJ……. Page 57 &59
PROTECTIVE FITTINGS

VIBRATION DAMPER ////


PRODUCT
////
CATEGORY
B
SECTION
PAGE 23

Vibration dampers are used to absorb aeolian vibration


of conductor, ground wire and OPGW on overhead
transmission lines.
These fittings can be supplied to ANSI, IEC and AS Standards as requested
Material:
Weights - Galvanized cast iron
Clamp - CP401 Aluminium alloy
Nut and bolt - Galvanized steel / Stainless steel
Messenger cable - Galvanized steel
PROTECTIVE FITTINGS

TWIN SPACER ////


////
CATEGORY

PRODUCT
B
SECTION
PAGE 24

Twin - Spacers are used to maintain conductor


spacing and to restore conductor spacing after a short
circuit occurs.

Material:
Body - Aluminium alloy
Conductor bush - EPDM

These fittings can be supplied to ANSI, IEC and AS


Standards as requested

Catalogue Conductor Dimensions, mm Approx.


Number Diameter Range. Weight
L
mm kg

S2-300 14~35 300 1.0

S2-330 14~35 330 1.1

S2-380 14~35 380 1.1

S2-420 14~35 420 1.2

S2-460 14~35 460 1.2

S2-500 14~35 500 1.3

S2-520 14~35 520 1.4


ARROW TWIN SPACER - DAMPERS
PROTECTIVE FITTINGS

////
PRODUCT
////
CATEGORY
B
SECTION
PAGE 25

Twin Spacer - Dampers are used to control aeolian vibration and


conductor oscillation, maintain conductor spacing and restore
conductor spacing after a short circuit occurs. Dulhunty "Arrow"
spacer dampers always face up

Material:
Frame, arm and keeper - Aluminium alloy
Nut and bolt - galvanized steel
Damping Element- EPDM rubber

These fittings can be supplied to ANSI, IEC and AS Standards as requested.

Catalogue Conductor Dimensions, mm Approx.


Number Diameter Range. L Weight
mm kg
SD2-400 18~40.4 400 2.6

SD2-450 18~40.4 450 2.7

SD2-457 18~40.4 457 2.7

SD2-500 18~40.4 500 2.8

SD2-600 18~40.4 600 3.0


ARROW TRIPLE SPACER - DAMPERS
PROTECTIVE FITTINGS

////
////
CATEGORY

PRODUCT
B
SECTION
PAGE 26

Triple Spacer - Dampers are used to control aeolian vibration and


conductor oscillation, maintain conductor spacing and restore
conductor spacing after a short circuit occurs. Dulhunty "Arrow"
spacer dampers always face up

Material:
Frame, arm and keeper - Aluminium alloy
Nut and bolt - galvanized steel
Damping Element - EPDM rubber

These fittings can be supplied to ANSI, IEC and AS Standards as requested.

Catalogue Conductor Dimensions, mm Approx.


Number Diameter Range. L Weight
mm kg

SD3-400 18~40.4 400 5.6

SD3-450 18~40.4 450 5.7

SD3-457 18~40.4 457 5.8

SD3-500 18~40.4 500 6.0


ARROW QUAD SPACER - DAMPERS
PROTECTIVE FITTINGS

////
PRODUCT
////
CATEGORY
B
SECTION
PAGE 27

Quad Spacer - Dampers are used to control aeolian vibration and


conductor oscillation, maintain conductor spacing and restore
conductor spacing after a short circuit occurs. Dulhunty "Arrow"
spacer dampers always face up

Material:
Frame, arm and keeper - Aluminium alloy
Nut and bolt - Galvanized steel
Damping Element - EPDM rubber

These fittings can be supplied to ANSI, IEC and AS Standards as requested.

Catalogue Conductor Dimensions, mm Approx.


Number Diameter Range. Weight
L
mm kg

SD4-400 18~40.4 400 7.3

SD4-450 18~40.4 450 7.5

SD4-457 18~40.4 457 7.5

SD4-500 18~40.4 500 7.7


PROTECTIVE FITTINGS

ARROW SIX BUNDLE SPACER - DAMPERS ////


////
CATEGORY

PRODUCT
B
SECTION
PAGE 28

Six bundle spacer - Dampers are used to control


aeolian vibration and conductor oscillation.
Maintain conductor spacing and restore conductor
spacing after a short circuit occurs. Dulhunty
"Arrow" spacer dampers always face up

Material:
Frame, arm and keeper - Aluminium alloy
Nut and bolt - Galvanized steel
Damping Element - EPDM rubber

Catalogue Approx.
Number Weight
kg

SD6:F1:762 11
PROTECTIVE FITTINGS

SPACER CLOSING TOOL ////


////
CATEGORY

PRODUCT
B
SECTION
PAGE 29

The quick and easy spacer closing tools are


used with the “QUICKLOCK” arms on the
spacer dampers.

Material:
Body – Ductile iron

Catalogue Approx.
Number Weight
kg

SD6TOOL 1.5
CAST BAR SPACER
LINE HARDWARE

////
////
CATEGORY

PRODUCT
C
SECTION
PAGE 30

Twin - Spacers are used to maintain conductor Material:


spacing and to restore conductor spacing after a Body – Aluminium
short circuit occurs Hardware - Galvanized steel

Catalogue Conductor Spacer Approx.


Number Diameter Range Length Weight
mm mm kg
CBS-200 14-35 200 0.4
CBS-380 14-35 380 0.6
CBS-400 14-35 400 0.6
CBS-520 14-35 520 0.8

Page 30
ANCHOR SHACLE
LINE HARDWARE

////
////
CATEGORY

PRODUCT
C
SECTION
PAGE 31

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Bolt Approx.


Number Failing load Diameter Weight
A B C D E F
kN Kg
Hole
AS-70 70 67 16 18 17 22.5 18 16 0.5
AS-120 120 67 16 18 17 22.5 18 16 0.5
AS-160 160 76 20 24 20 24.5 22 20 1.0

C
E
Material:
Body - Galvanized steel
Hardware - Galvanized steel
Split pin - Stainless steel F

B
LINE HARDWARE

BALL EYE LINK ////


PRODUCT
////
CATEGORY
C
SECTION
PAGE 32

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Approx.


Number Failing load Weight
A B C
kN Kg
BEL-70 70 100 50 16 0.4
BEL-120 120 100 50 16 0.4
BEL-160 160 128 64 20 0.7

C
Material:
Galvanized steel

The ball dimension is in


accordance with AS1154.1 : 2004
B

A
LINE HARDWARE

BALL CLEVIS ////


PRODUCT
////
CATEGORY
C
SECTION
PAGE 33

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Approx.


Number Failing Weight
load kg
kN A B C D Ball F Material:
Hole Body - Galvanized steel
Bolt and nut - Galvanized steel

BC-70 70 20 22 28 78 16 18 0.7 Split pin - stainless steel

BC-120 120 20 22 28 78 16 18 0.7 The ball dimension is in


accordance with AS1154.1 : 2004
BC-160 160 24 24 35 95 20 22 1.1

B
F

D
LINE HARDWARE

CLEVIS TONGUE ////


PRODUCT
////
CATEGORY
C
SECTION
PAGE 34

D Material:
Body - Galvanized steel
Bolt and Nut - Galvanized steel
Split pin - stainless steel

A
B

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Approx.


Number Failing Weight
load kg
A B C D E φ
kN

CT-70 70 22 16 28 20 72 18 0.7

CT-120 120 22 16 28 20 72 18 0.7

CT-160 160 24 20 35 24 86 22 1.1 φ


TWISTED CLEVIS TONGUE
LINE HARDWARE

////
PRODUCT
////
CATEGORY
C
SECTION
PAGE 35

Material:
Body - Galvanized steel
Bolt and Nut - Galvanized steel
Split pin - Stainless steel

Catalogue Minimum Dimension, mm Approx.


Number Failing Weight
load A B D E S φH kg
kN

TCT-70 70 16 20 22 28 76 18 0.7

TCT-120 120 16 20 22 28 76 18 0.7

TCT-160 160 20 24 24 35 76 22 1.1


SOCKET CLEVIS EXTENSION LINK
LINE HARDWARE

////
PRODUCT
////
CATEGORY
C
SECTION
PAGE 36

Material:
Body - Galvanized forged steel
Bolt and nut - Galvanized steel
Split pin - stainless steel

G The socket dimensions are in accordance


A with AS 1154.1 : 2004
B

F
The SCEL can be supplied with either
"W" type clips or "R" type clips

D E

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Approx.


Number Failing Weight
load kg
kN A B C D E F G
Max

SCEL-160 160 215 155 35 24 22 24 23 2.0


LINE HARDWARE

BALL EYE EXTENSION LINK ////


PRODUCT
////
CATEGORY
C
SECTION
PAGE 37

C Material:
Body - Galvanized forged steel
The ball is in accordance with AS
A
1154.1 : 2004

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Approx.


Number Failing Weight
load kg
Ball A B C D E
kN

BEEL-160- 160 20 64 250 32 24 20 1.3


250
BEEL-160- 160 20 64 500 32 24 20 2.3
500
BEEL-160- 160 20 64 800 32 24 20 3.4
800
LINE HARDWARE

CHAIN LINK ////


////
CATEGORY

PRODUCT
C
SECTION
PAGE 38

Material:
D
Galvanized steel

Catalogue Minimum Dimension, mm Approx.


Number Failing Weight
load A B C D
Kg
kN

CL-70 70 50 16 26 16 0.4

CL-120 120 50 16 26 16 0.4

CL-160 160 64 20 32 20 0.8


LINE HARDWARE

SOCKET CLEVIS ////


PRODUCT
////
CATEGORY
C
SECTION
PAGE 39

Material:
Body - Galvanized forged steel
Bolt and nut - Galvanized steel
Split pin - Stainless steel
B
C
The socket dimension is in accordance
with AS 1154.1 : 2004

The SC can be supplied with either


"W" type clips or "R" type clips.
A E

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Approx.


Number Failing load Weight
kN A B C D E kg

SC-70 70 20 59 28 18 22 1.4

SC-120 120 20 59 28 18 22 1.4

SC-160 160 24 62 35 22 24 2.6


LINE HARDWARE

SOCKET TONGUE ////


PRODUCT
////
CATEGORY
C
SECTION
PAGE 40

Material:
Body - Galvanized forged steel

The socket dimension is in accordance


B with AS 1154.1 : 2004

The ST can be supplied with either


"W" type clips or "R" type clips.

A STT70
C

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Approx.


Number Failing load Weight
kN A B C Hole
kg

ST-70 70 16 57 44 18 0.8

ST-120 120 16 57 44 18 0.8

ST-160 160 20 57 48 22 1.3

STT-70 70 16 57 44 18 0.8
LINE HARDWARE

TWISTED EYE TONGUE ////


PRODUCT
////
CATEGORY
C
SECTION
PAGE 41

C A Material:
Body - Galvanized forged steel

Catalogue Minimum Dimension, mm Approx.


Number Failing load Weight
kN A B C D E φ
kg

TET-70 70 16 100 26 51 16 18 0.6

TET-120 120 16 100 26 51 16 18 0.6

TET-160 160 20 112 32 64 20 22 1.0


BALL HOOK LONG SHANK
LINE HARDWARE

////
////
CATEGORY

PRODUCT
C
SECTION
PAGE 42

A Material:
Body - Galvanized forged steel

The ball dimension is in accordance


C B with AS 1154.1 : 2004

F
D

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Approx.


Number Failing load Weight
kN A B C D E (ball) F
kg

BH-70-LS 70 25 32 32 25 16 82 0.6

BH-120-LS 120 25 32 32 25 16 82 0.6

BH-160-LS 160 25 34 60 25 20 102 0.9


BALL HOOK SHORT SHANK
LINE HARDWARE

////
////
CATEGORY

PRODUCT
C
SECTION
PAGE 43

A
Material:
Body - Galvanized
forged steel

The ball dimension is


B in accordance
with AS 1154.1 : 2004
C

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Approx.


Number Failing load Weight
kN A B C D E (ball) F
kg

BH-70-SS 70 25 32 29 21 16 57 0.5

BH-120-SS 120 25 32 29 21 16 57 0.5


LINE HARDWARE

TONGUE HOOK ////


////
CATEGORY

PRODUCT
C
SECTION
PAGE 44

Material:
Body - Galvanized forged steel

Catalogue Minimum Dimension, mm to AS1154.1 : 2004 Approx.


Number Failing Weight
load A B C E φH K
kg
kN
TH-70 70 25 32 32 25 18 16 0.7
LINE HARDWARE

SOCKET THIMBLE ////


////
CATEGORY

PRODUCT
C
SECTION
PAGE 45

SOCTL-70 SOCT-70

Catalogue Minimum Dimension, mm Approx. Material:


Failing load Body - Galvanized ductile iron
Number Socket Weight
“w” clip – Bronze.
kN kg

SOCT-70 70 16 0.9

SOCTL-70 70 16 1.1
LINE HARDWARE

CLEVIS THIMBLE ////


////
CATEGORY

PRODUCT
C
SECTION
PAGE 46

D
D

A
A

Body style - CTHI-1850 Aluminium alloy - CTHA-42 Body style - CTHAL-70

Catalogue Minimum Dimension, mm Approx.


D
Number Failing Weight
load kg
kN D φ A

CTHA-42 42 20 16 60 0.4

CTHA-2600 70 26 16 54 0.5

CTHAL-70 70 20 16 60 0.7
Body style – CTHA-2600
CTHI-1850 70 18.5 16 38 0.5

Material:
Body - Galvanized ductile iron (CTHI-1850) Aluminium alloy (CTHA-2600)
Aluminium alloy (CTHA-42) Aluminium alloy (CTHAL-70)
Hardware - Galvanized steel
Split pin - Stainless steel
ALUMINIUM PARALLEL GROOVE CLAMPS
LINE HARDWARE

////
PRODUCT
////
CATEGORY
C
SECTION
PAGE 47

PGA- 0890-1880

PGA-185630/3

Catalogue Overall sq mm Number Length Approx. Material:


Body - Aluminium
Number Diameter of bolts mm Weight
Bolts - Galvanized
mm kg

PGA- 1670/1 5.1 - 11.3 16 - 70 1 25 0.1

PGA- 0890-1880 8.9 – 18.8 50 - 185 2 70 0.4

PGA- 35185/2 7.5 - 17.5 35 - 185 2 70 0.4

PGA- 35240/2 7.5 - 20.0 35 - 240 2 70 0.4

PGA- 35300/3 7.5 - 22.5 35 - 300 3 105 0.6

PGA- 185630/3 16.5 - 33.0 185 - 630 3 190 2.0


BIMETAL PARALLEL GROOVE CLAMPS
LINE HARDWARE

////
////
CATEGORY

PRODUCT
C
SECTION
PAGE 48

Material:
Body - Aluminium with a bimetallic sheet
(hot forged)
Bolts - Galvanized

Catalogue Overall sq mm Overall sq mm Number Length Approx.


Number Diameter Aluminium Diameter Copper of bolts mm Weight
Aluminium Copper kg

PGB-1670/2 5.1 - 11.7 16 - 70 3.0 - 9.0 6 - 50 2 40 0.1

PGB-35120/1 7.5 - 14.0 35 - 120 3.5 - 9.0 10 - 50 1 30 0.1

PGB-25150/1 6.3 - 15.7 25 - 150 4.1 - 12.5 10 - 95 1 28 0.1

PGB-25150/2 6.3 - 15.7 25 - 150 4.1 - 12.5 10 - 95 2 48 0.2

PGB-16185/2 7.5 - 17.5 35 - 185 6.0 - 17.5 16 - 185 2 63 0.3

PGB-35185/3 7.5 - 17.5 35 - 185 7.5 - 17.5 35 - 185 3 95 0.6

PGB-35300/3 7.5 - 22.5 35 - 300 7.5 - 20.0 35 - 240 3 105 0.6


COPPER PARALLEL GROOVE CLAMPS
LINE HARDWARE

////
PRODUCT
////
CATEGORY
C
SECTION
PAGE 49

Material:
Body - Copper (Hot forged)
Bolts - Copper alloy

Catalogue Overall sq mm Number Length Approx.


Number Diameter of bolts mm Weight
kg

PGC-670/1 2.7 - 10.5 6 - 70 1 25 0.1

PGC-1095/2 3.5 - 12.5 10 - 95 2 42 0.3

PGC-16150/2 4.5 - 15.7 16 - 150 2 50 0.5


LINE HARDWARE

BIMETAL SERVICE CLAMPS ////


////
CATEGORY

PRODUCT
C
SECTION
PAGE 50

Catalogue Overall Number Approx.


Number Diameter of bolts Weight
mm kg

ASC1- 7 - 18.8 1 0.2

ASC2- 7 - 18.8 2 0.2

Material:
Body - Aluminium
Split Bolt - Tinned Brass
Suffix Bolts - A- Aluminium ASC1-S ASC2-S
S -Stainless steel
G -Galvanized

Catalogue Conductor Diameter Number Approx.


Number Overall of stirrup of bolts Weight
Diameter mm kg
mm

ASC4- 7 - 18.8 8 1 0.2

ASC5- 7 - 18.8 8 2 0.3

Material:
Body - Aluminium
Stirrup - Tinned Copper ASC5-A ASC4-A
Suffix Bolts - A - Aluminium
S - Stainless steel
G - Galvanized
LINE HARDWARE

BIMETAL SERVICE TEES ////


////
CATEGORY

PRODUCT
C
SECTION
PAGE 51

AST9-500-S

Material:
Body - Aluminium
Stirrup - Tinned Copper
Suffix Bolts - A- Aluminium
S -Stainless steel
G -Galvanized
ASC5-8.25T DTA-1-S

Catalogue Conductor Length Approx. Catalogue Conductor Bail Approx.


Number Overall mm Weight Number Overall Weight
Diameter kg Diameter mm kg
mm
DTA-1- 7 – 18.8 Solid Tinned 0.6
Bronze
AST9-500- 7 - 18.8 500 0.5

ASC5-8.25T 7 - 18.8 Solid Tinned 0.3


Copper
LINE HARDWARE

KU-LUGS ////
PRODUCT
////
CATEGORY
C
SECTION
PAGE 52

C
D

A
B

E
Material:
Body - High copper content alloy

Catalogue Diameter Area


Number mm sqmm A B C D E

KU-2 4.05 - 5.10 10 -16 23 19 44 M8 6


KU-3 6.75 - 7.65 25 - 35 28 25 53 M10 6
KU-4 8.90 - 10.70 50 - 70 36 31 60 M12 7
KU-5 10.70 - 12.60 70 - 95 42 31 65 M12 8
KU-6 15.75 - 17.64 150 - 185 48 36 75 M16 10
KU-7 17.64 - 20.25 185 - 240 51 39 80 M20 10
KU-8 22.68 - 25.65 300 - 400 63 51 98 M20 13
LINE HARDWARE

SPLIT BOLTS ////


////
CATEGORY

PRODUCT
C
SECTION
PAGE 53

Material:
Body - Tinned or Natural Brass

Catalogue Catalogue Slot Width Max ESAA Cross


Number Number (mm) Conductor Reference
Natural Electro (sqmm)
Brass Tinned
SB-22 SBT-22 5.3 16 Type A
SB-24 SBT-24 8.3 35 Type B
SB-25 SBT-25 10.9 70 Type C
SB-26 SBT-26 12.9 95 Type D
SB-28 SBT-28 18.5 185 Type E
LINE HARDWARE

SPLIT BOLTS ////


PRODUCT
////
CATEGORY
C
SECTION
PAGE 54

Material:
Hot dip galvanized

A strong means of securing guy / stay wires

Catalogue A B C D E F G
Number (mm) (mm) (mm) (mm) Nominal (mm) (mm)
wire
(dia.. mm)
WRG-08 8 41 17 22 8 36 8
WRG-10 10 49 20 27 10 44 10
WRG-12 12 59 24 32 11 51 12
WRG-16 14 77 31 41 16 63 14
LINE HARDWARE

GAIN BLOCK ////


////
CATEGORY

PRODUCT
C
SECTION
PAGE 55

Material:
Cast Aluminium

Catalogue Crossarm
Number (mm)

GB-100 100

GB-125 125
COMPRESSION DEAD END ACSR
LINE HARDWARE

////
PRODUCT
////
CATEGORY
C
SECTION
PAGE 56

Tongue tail
Eye tail

Catalogue ACSR Outside Inside A/F Outside diameter Inside Diameter A/F Steel
Number tube diameter tube diameter Aluminium Mm Steel mm Steel
mm Aluminium mm Aluminium

CDE-ALMOND 6/1/2.50 16.5 9.5 14.0 7.8 3.1 6.8


CDE-APPLE 6/1/3.00 16.5 10.5 14.0 7.8 3.4 6.8
CDE-BANANA 6/1/3.75 21.0 12.5 18.0 11.0 4.2 9.5
CDE-CHERRY 6/4.75+7/1.60 26.0 16.0 22.0 11.0 5.2 9.5
CDE-GRAPE 30/7/2.50 33.0 19.5 28.5 18.5 8.2 16.0
CDE-LEMON 30/7/3.00 39.5 23.0 34.5 19.7 9.8 17.0
CDE-LIME 30/7/3.50 46.0 26.5 40.0 22.0 11.5 19.0
CDE-MANGO 54/7/3.00 46.0 28.5 40.0 19.7 9.8 17.0
CDE-ORANGE 54/7/3.25 51.0 31.5 44.5 22.0 10.6 19.0
CDE-OLIVE 54/7/3.50 54.0 34.0 47.5 22.0 11.5 19.0
CDE-PAWPAW 54/3.75+19/2.25 54.0 35.2 47.5 23.0 12.0 20.0

Please refer to our nearest sales office for further information


COMPRESSION MIDSPAN ACSR
LINE HARDWARE

////
////
CATEGORY

PRODUCT
C
SECTION
PAGE 57

Outside Inside Outside Inside


tube tube diameter diameter
Catalogue ACSR diameter diameter A/F mm mm A/F
Number mm mm Aluminium Steel Steel Steel
Aluminium Aluminium

CMJ-ALMOND 6/1/2.50 16.5 9.5 14.0 7.8 3.1 6.8


CMJ-APPLE 6/1/3.00 16.5 10.5 14.0 7.8 3.4 6.8
CMJ-BANANA 6/1/3.75 21.0 12.5 18.0 11.0 4.2 9.5
CMJ-CHERRY 6/4.75+7/1.60 26.0 16.0 22.0 11.0 5.2 9.5
CMJ-GRAPE 30/7/2.50 33.0 19.5 28.5 18.5 8.2 16.0
CMJ-LEMON 30/7/3.00 39.5 23.0 34.5 19.7 9.8 17.0
CMJ-LIME 30/7/3.50 46.0 26.5 40.0 22.0 11.5 19.0
CMJ-MANGO 54/7/3.00 46.0 28.5 40.0 19.7 9.8 17.0
CMJ-ORANGE 54/7/3.25 51.0 31.5 44.5 22.0 10.6 19.0
CMJ-OLIVE 54/7/3.50 54.0 34.0 47.5 22.0 11.5 19.0
CMJ-PAWPAW 54/3.75+19/2.25 54.0 35.2 47.5 23.0 12.0 20.0

Please refer to our nearest sales office for further information


COMPRESSION DEAD END AAC & AAAC
LINE HARDWARE

////
////
CATEGORY

PRODUCT
C
SECTION
PAGE 58

Eye tail Tongue tail

Outside Inside Outside Inside


tube tube tube tube
Catalogue AAC diameter diameter A/F AAC diameter diameter A/F
Number and mm mm Aluminium Catalogue and mm mm Aluminium
AAAC Aluminium Aluminium Number AAAC Aluminium Aluminium

CDE-LEO 7/2.50 16.5 9.5 14.0


CDE-PLUTO 19/3.75 33.0 20.3 28.5
CDE-DIAMOND
CDE-PEARL
CDE-LIBRA 7/3.00 16.5 10.5 14.0
CDE-SATURN 37/3.00 39.5 23.0 34.5
CDE-EMERALD
CDE-RUBY
CDE-MARS 7/3.75 21.0 12.5 18.0
CDE-TAURUS 19/4.75 46.0 26.5 40.0
CDE-GARNET
CDE-RUTILE
CDE-MERCURY 7/4.50 26.0 16.0 22.0 CDE-TRITON 37/3.75 46.0 28.5 40.0
CDE-JADE CDE-SAPPHIRE
CDE-MOON 7/4.75 26.0 16.0 22.0 CDE-URANUS 61/3.25 51.0 31.5 44.5
CDE-JASPER CDE-SPINEL
CDE-NEPTUNE 19/3.25 33.0 18.0 28.5 CDE-VENUS 61/3.75 54.0 35.2 47.5
CDE-OPAL CDE-TOPAZ

Please refer to our nearest sales office for further information


COMPRESSION MIDSPAN AAC & AAAC
LINE HARDWARE

////
////
CATEGORY

PRODUCT
C
SECTION
PAGE 59

Catalogue AAC Outside Inside A/F Catalogue AAC Outside Inside A/F
Number and tube diameter tube diameter Aluminium Number and tube diameter tube Diameter Aluminium
AAAC mm Aluminium mm Aluminium AAAC Mm Aluminium Mm Aluminium

CMJ-LEO 7/2.50 16.5 9.5 14.0 CMJ-PLUTO 19/3.75 33.0 20.3 28.5
CMJ-DIAMOND CMJ-PEARL

CMJ-LIBRA 7/3.00 16.5 10.5 14.0 CMJ-SATURN 37/3.00 39.5 23.0 34.5
CMJ-EMERALD CMJ-RUBY

CMJ-MARS 7/3.75 21.0 12.5 18.0 CMJ-TAURUS 19/4.75 46.0 26.5 40.0
CMJ-GARNET CMJ-RUTILE

CMJ-MERCURY 7/4.50 26.0 16.0 22.0 CMJ-TRITON 37/3.75 46.0 28.5 40.0
CMJ-JADE CMJ-SAPPHIRE

CMJ-URANUS 61/3.25 51.0 31.5 44.5


CMJ-MOON 7/4.75 26.0 16.0 22.0
CMJ-SPINEL
CMJ-JASPER
CMJ-VENUS 61/3.75 54.0 35.2 47.5
CMJ-NEPTUNE 19/3.25 33.0 18.0 28.5
CMJ-TOPAZ
CMJ-OPAL

Please refer to our nearest sales office for further information


HELIXON FITTINGS

INDEX ////
////
CATEGORY

PRODUCT
D
SECTION
PAGE 60

Aluminium Deadend Type DE-A ……………………… Page 61


Galvanized Steel Deadend Type DE-S.……………………… Page 62
Aluminium Armour Rods Type AR-A………………………. Page 63
Galvanized Steel Armour Rods Type AR-S………………………. Page 64
Aluminium Line Guards Type LG-A………………………. Page 65
Aluminium Conductor Splices Type LS-A……………………….. Page 66
Galvanized Steel Conductor Splices Type LS-S……………………….. Page 67
Full Tension Conductor Splices Type LS-FT…………………….. Page 68
Galvanized Steel Guy Lock Type GL-S………………………. Page 69
Guy Guard Type GG-P……………………… Page 70
Spiral Vibration Damper Type HVD……………………….. Page 71
Bird Diverters Type BFD ………………………. Page 72
ALUMINIUM DEADENDS
HELIXON

////
////
CATEGORY

PRODUCT
D
SECTION
PAGE 61

Conductors AS1154
Catalogue Outside Pack Colour
AAC
Number Diameter Size Code
AAAC ACSR

DE-A 05.25 7/1.75 3/4/1.75 5.25 50 Purple

DE-A 06.75 7/2.25 – 6.75 50 Brown

6/1/2.50
DE-A 07.50 7/2.50 7.50 50 Blue
3/4/2.50
Type DE-A Aluminium Deadends 6/1/3.00
DE-A 09.00 7/3.00 9.00 50 Red
4/3/3.00
Material
6/1/3.75
Aluminium Deadends are manufactured using high strength, DE-A 11.25 7/3.75 11.25 25 Black
4/3/3.75
corrosion resistant aluminium alloy wire. Aluminium dead ends may
be used in all environments. DE-A 13.50 7/4.50 – 13.50 20 Green

DE-A 14.30 7/4.75 6/1/4.75+ 14.30 20 Blue


Rated Holding Strength 7/1.60
Aluminium Deadends are designed to hold the full rated strength of
DE-A 16.25 19/3.25 – 16.25 15 Orange
Aluminium (AAC) or aluminium alloy (AAAC) conductors.
DE-A 17.50 – 30/7/2.50 17.50 10 Blue
Please consult Dulhunty for holding strength on ACSR conductors. DE-A 18.75 19/3.75 – 18.75 10 Black

Tapping DE-A 21.00 37/3.00 30/7/3.00 21.00 10 Red


Current taps should not be attached over a deadend. Current taps DE-A 23.75 19/4.75 – 23.75 10 Blue
should be made directly on the conductor on either side of the dead
end.
GALVANIZED STEEL DEAD END
HELIXON

////
////
CATEGORY

PRODUCT
D
SECTION
PAGE 62

AS1154
Catalogue Conductors Outside Pack Colour
Number SC/GZ Diameter Size Code

DE-S 04.31 3/2.00 4.31 50 Yellow

DE-S 04.80 7/1.60 4.80 50 Black

Type DE-S Steel Deadends DE-S 05.93 3/2.75 5.93 50 White

Material DE-S 06.00 7/2.00 6.00 50 Yellow


Steel Deadends are manufactured using high strength
galvanized steel wire. Steel deadends may be used in all DE-S 08.25 7/2.75 8.25 20 White
environments for which SC/GZ galvanized steel conductor 7/3.25 9.75 15 Orange
or guy wire may be used. DE-S 09.75D
19/2.00 10.00 15 Yellow
Rated Holding Strength
Steel Deadends are designed to hold the rated strength of DE-S 11.25 7/3.75 11.25 20 Black
SC/GZ galvanized steel conductors and guy wires.
DE-S 12.00 7/4.00 12.00 15 Black
Tapping DE-S 13.75 19/2.75 13.75 10 White
Current taps should not be attached over a deadend.
Current taps should be made directly on the conductor on DE-S 16.25 19/3.25 16.25 5 Orange
either side of the deadend.

DE-S 0825, DE-S 0975 and DE-S 1375 are suitable for use with
either a standard thimble, or with GY3 and GY4 insulators.
ALUMINUM ARMOUR RODS
HELIXON

////
PRODUCT
////
CATEGORY
D
SECTION
PAGE 63

Conductors AS1154
Catalogue Outside Pack Colour
AAC
Number Diameter Size Code
AAAC ACSR

Type AR-A Aluminium Armour Rods AR-A 05.25 7/1.75 3/4/1.75 5.25 50 Purple

AR-A 06.75 7/2.25 – 6.75 50 Brown


Material
AR-A 07.50 7/2.50 6/1/2.50 7.50 50 Blue
Aluminium Armour rods are manufactured using high strength
corrosion resistant aluminium alloy wire. Aluminium armour rods may AR-A 07.50 – 3/4/2.50 7.50 50 Blue
be used in all environments. AR-A 09.00 7/3.00 6/1/3.00 9.00 40 Red

Application AR-A 09.00 – 4/3/3.00 9.00 40 Red


Armour rods are designed to help prevent damage to conductors AR-A 11.25 7/3.75 6/1/3.75 11.25 25 Black
caused by bending, by high clamping stresses, by abrasion at support
AR-A 11.25 – 4/3/3.75 11.25 25 Black
points and damage caused by arcing. Armour rods are not vibration
dampers but help to prevent vibration damage to conductors by AR-A 13.50 7/4.50 – 13.50 20 Green
increasing the stiffness of the conductor at the support point and by AR-A 14.30 7/4.75 6/4.75+7/1.60 14.30 20 Blue
preventing abrasion to the strands of the conductor.
AR-A 16.25 19/3.25 – 16.25 15 Orange

Armour rods can also be used to repair minor damage to the outer AR-A 17.50 – 30/7/2.50 17.50 15 Blue
strands of the conductor. Please consult Dulhunty for specific
AR-A 18.75 19/3.75 – 18.75 10 Red
information on damage repair.
AR-A 21.00 37/3.00 30/7/3.00 21.00 5 Red
Tapping AR-A 23.75D 19/4.75 – 23.75 5 Blue
Taps may be applied over armour rods, but scratch brushing and
greasing of the conductor is recommended if taps are to be applied.
GALVANISED ARMOUR RODS
HELIXON

////
PRODUCT
////
CATEGORY
D
SECTION
PAGE 64

Catalogue Conductors Outside Pack AS1154


Number SC/GZ Diameter Size Colour
Code
Type AR-S Steel Armour Rods
AR-S 04.31 3/2.00 4.31 50 Yellow
Material
Steel Armour rods are manufactured using high strength 7/1.60 4.80 50 Black
galvanized steel wire. Steel armour rods may be used in all
AR-S 04.80D 3/2.75 5.93 50 White
environments for which galvanized steel conductors or guy
wires are used. 7/2.00 6.00 50 Yellow

Application AR-S 08.25 7/2.75 8.25 30 White


Armour rods are designed to help prevent damage to
conductors caused by bending, by high clamping stresses, by 7/3.25 9.75 20 Orange
abrasion at support points and damage caused by arcing. AR-S 09.75D
19/2.00 10.00 20 Yellow
Armour rods are not vibration dampers but help to prevent
vibration damage to conductors by increasing the stiffness of AR-S 11.25 7/3.75 11.25 20 Black
the conductor at the support point and by preventing abrasion
to the strands of the conductor. AR-S 12.00 7/4.00 12.00 15 Black

Armour rods can also be used to repair minor damage to the AR-S 13.75 19/2.75 13.75 10 White
outer strands of the conductor. Please consult Dulhunty for AR-S 16.25 19/3.25 16.25 5 Orange
specific information on damage repair.

Tapping
Taps may be applied over armour rods, but scratch brushing Note: Suffix D in Cat. No. denotes fitting suits more than one conductor.
and greasing of the conductor is recommended if taps are to be
applied.
.
ALUMINIUM LINE GUARDS
HELIXON

////
////
CATEGORY

PRODUCT
D
SECTION
PAGE 65

Catalogue Conductors Outside Pack AS1154


Number Diameter Size Colour
AAC
Code
AAAC ACSR

Type LG-A Aluminium Line Guards LG-A 05.25 7/1.75 3/4/1.75 5.25 50 Purple
LG-A 06.75 7/2.25 – 6.75 50 Brown
Material
Aluminium Line Guards are manufactured using high 6/1/2.50
LG-A 07.50 7/2.50 7.50 50 Blue
strength corrosion resistant aluminium alloy wire. Aluminium 3/4/2.50
Line Guards may be used in all environments. 6/1/3.00
LG-A 09.00 7/3.00 9.00 50 Red
4/3/3.00
Application
Line Guards are designed to help reduce damage to 6/1/3.75
LG-A 11.25 7/3.75 11.25 40 Black
conductors caused, by abrasion at support points and 4/3/3.75
damage caused by arcing. Armour rods should generally be LG-A 13.50 7/4.50 – 13.50 25 Green
used in areas where vibration is likely. Line Guards can also
be used to repair minor damage to the outer strands of the LG-A 14.30 7/4.75 6/4.75+7/1.60 14.30 25 Blue
conductor. Please consult Dulhunty for specific information
LG-A 16.25 19/3.25 – 16.25 25 Orange
on damage repair.
LG-A 17.50 – 30/7/2.50 17.50 25 Blue
Tapping
LG-A 18.75 19/3.75 – 18.75 25 Black
Taps may be applied over Line Guards, but scratch brushing
and greasing of the conductor is recommended if taps are to LG-A 21.00 37/3.00 30/7/3.00 21.00 25 Red
be applied.
LG-A 23.75 19/4.75 – 23.75 20 Blue
ALUMINIUM CONDUCTOR SPLICES
HELIXON

////
PRODUCT
////
CATEGORY
D
SECTION
PAGE 66

Catalogue Conductors Outside Pack AS1154


Number AAC Diameter Size Colour
AAAC Code

LS-A 05.25 7/1.75 5.25 50 Purple

LS-A 06.75 7/2.25 6.75 50 Brown


Type LS-A Aluminium Splices
LS-A 07.50 7/2.50 7.50 50 Blue
Material
LS-A 09.00 7/3.00 9.00 40 Red
Aluminium Splices are manufactured using high strength
corrosion resistant aluminium alloy wire. Aluminium Splices LS-A 11.25 7/3.75 11.25 20 Black
may be used in all environments.
LS-A 13.50 7/4.50 13.50 10 Green
Rated Holding Strength
Aluminium Splices are designed to hold the full rated LS-A 14.30 7/4.75 14.30 10 Blue
strength of Aluminium (AAC) or aluminium alloy (AAAC)
LS-A 16.25 19/3.25 16.25 10 Orange
conductors. Aluminium Splices are designed to carry the full
oad current of AAC and AAAC conductors. Scratch LS-A 17.50 – 17.50 5 Blue
brushing and greasing of the conductor is recommended
prior to the installation of Aluminium Splices LS-A 18.50 19/3.75 18.75 5 Black

Please consult Dulhunty for mechanical holding strength of LS-A 21.00 37/3.00 21.00 5 Red
Aluminium Splices on ACSR Conductors. LS-A 23.75 19/4.75 23.75 5 Blue
GALVANISED CONDUCTOR SPLICES
HELIXON

////
PRODUCT
////
CATEGORY
D
SECTION
PAGE 67

Catalogue Conductors Outside Pack AS1154


Number SC/GZ Diameter Size Colour
Code

LS-S 04.31 3/2.00 4.31 50 Yellow

LS-S 04.80 7/1.60 4.80 50 Black

LS-S 05.93 3/2.75 5.93 50 White

Type LS-S Steel Splices LS-S 06.00 7/2.00 6.00 40 Yellow

LS-S 08.25 7/2.75 8.25 20 White


Material
Steel Splices are manufactured using high strength galvanized 7/3.25 9.75 20 Orange
steel wire. Steel Splices may be used in all environments for LS-S 09.75D
which galvanized steel conductor or guy wire may be used. 19/2.00 10.00 20 Yellow

Rated Holding Strength LS-S 11.25 7/3.75 11.25 20 Black


Steel Splices are designed to hold the full rated strength of
LS-S 12.00 7/4.00 12.00 15 Black
galvanized steel conductors or guy wires. Steel Splices are
designed to carry the full load current of galvanized steel LS-S 13.75 19/2.75 13.75 10 White
conductors
LS-S 16.25 19/3.25 16.25 5 Orange

Note: Suffix D in Cat. No. denotes fitting suits more than one conductor.
FULL TENSION CONDUCTOR SPLICES
HELIXON

////
////
CATEGORY

PRODUCT
D
SECTION
PAGE 68

Catalogue Conductors Outside Pack AS1154


Number ACSR Diameter Size Colour
Code

LS-FT 05.25M 3/4/1.75 5.25 50 Purple

LS-FT 07.50 6/1/2.50 7.50 40 Blue

LS-FT 07.50M 3/4/2.50 7.50 50 Blue

LS-FT 09.00 6/1/3.00 9.00 20 Red

LS-FT 09.00M 4/3/3.00 9.00 25 Red


Type LS-FT Full Tension Splices
LS-FT 11.25 6/1/3.75 11.25 10 Black
Material
Full Tension Splices are two piece fittings with aluminium rods LS-FT 11.25M 4/3/3.75 11.25 25 Black
manufactured using high strength corrosion resistant aluminium
LS-FT 14.30 6/4.75+7/1.60 14.30 10 Blue
alloy wire, and steel rods manufactured using high strength
corrosion resistant aluminium alloy wire. Full Tension Splices may LS-FT 17.50 30/7/2.50 17.50 5 Blue
be used in all environments for which ACSR conductors are used.
LS-FT 21.00 30/7/3.00 21.00 5 Red
Rated Holding Strength
Full Tension Splices are designed to hold the full rated strength of
ACSR conductors. Aluminium Splices are designed to carry the full
load current of ACSR conductors
GALVANISED GUY LOCKS
HELIXON

////
PRODUCT
////
CATEGORY
D
SECTION
PAGE 69

Catalogue Conductors Outside Pack AS1154


Number SC/GZ Diameter Size Colour
Code

GL-S 04.31 3/2.00 4.31 50 Yellow


Type GL-S Steel Guy Locks
GL-S 04.80 7/1.60 4.80 50 Black
Material
Steel guy locks are manufactured using high strength GL-S 05.93 3/2.75 5.93 50 White
Galvanized steel wire. Steel guy locks may be used in all
environments for which galvanized steel conductor or guy wire GL-S 06.00 7/2.00 6.00 40 Yellow
may be used. GL-S 08.25 7/2.75 8.25 20 White

Rated Holding Strength 7/3.25 9.75 20 Orange


Steel guy locks are designed to hold the full rated strength of GL-S 09.75D
galvanized steel guy wires. 19/2.00 10.00 20 Yellow

GL-S 11.25 7/3.75 11.25 20 Black

GL-S 12.00 7/4.00 12.00 15 Black

GL-S 13.75 19/2.75 13.75 10 White

GL-S 16.25 19/3.25 16.25 5 Orange

Note: Suffix D in Cat. No. denotes fitting suits more than one conductor.
GUY GUARDS
HELIXON

////
PRODUCT
////
CATEGORY
D
SECTION
PAGE 70

Application: Catalogue Internal Dia. Std Pack


The Dulhunty Power Guy Guard improves visibility of pole Number mm Length Size
stays to help avoid accidental contact with the guy wire.

Material:
White, UV resistant PVC. GG-P 2520 25 tube 2.0m 50

GG-P 2520S 25 split tube 2.0m 50

GG-P 3020 30 tube 2.0m 50

GG-P 3020S 30 split tube 2.0m 50

GG-P 3025 30 tube 2.5m 50

GG-P 3524 35 tube 2.4m 50

Notes: Suffix S in Cat. No. indicates fitting is split.


HELIXON VIBRATION DAMPERS
HELIXON

////
////
CATEGORY

PRODUCT
D
SECTION
PAGE 71

Type HVD Vibration Dampers Catalogue Conductors Std Colour


Helixon Vibration dampers are designed to control vibration Number Dia. Range Pack Code
on small diameter conductors.
Helixon Vibration dampers do not dissipate energy, but control HVD-044 4.4 - 6.3 25 Red
vibration to disrupt vibration build up, by impacting on the
conductor. HVD-063 6.4 - 8.2 25 Blue

Material HVD-083 8.3 - 11.7 25 Black


Helixon Vibration dampers are manufactured using a high
impact strength, UV resistant plastic. They are suitable for use HVD-117 11.8 - 14.4 25 Yellow
in all environments, and may be used for conductor
HVD-143 14.5 - 19.5 8 Green
temperatures up to 75C°.
BIRD DIVERTERS
HELIXON

////
////
CATEGORY

PRODUCT
D
SECTION
PAGE 72

5 metre 5 metre

.2.5 metre stagger

5 metre 5 metre

Typical spacing layout

Application: Catalogue Conductor Std Colour


The bird diverters manufactured by Dulhunty Power are designed to
Number Dia. Range Pack Code
make power lines more visible for birds and to reduce the number of
injuries to birds caused by striking power lines.
BFD-044 4.4 - 6.3 50 Red
Dulhunty Power bird diverters are orange, as this has been proven BFD-063 6.4 - 8.2 50 Blue
to be the most visible colour to the birds.
BFD-083 8.3 - 11.7 50 Black
Materials:
High impact strength UV resistant PVC rod. BFD-117 11.8 - 14.4 50 Yellow

Installation: BFD-143 14.5 - 19.5 50 Green


Dulhunty Power recommends that the bird diverters should be
installed on the outer conductors as shown in the diagram.
STRAIN AND SUSPENSION CLAMPS

INDEX ////
////
CATEGORY

PRODUCT
E
SECTION
PAGE 73

Aluminium Suspension Clamp Type ASC………………………. Page 74


Aluminium Pivot Suspension Clamp Type PSC………………………. Page 75
Aluminium Trunnion Support Clamp Type TSC…...……………………Page 76
Helixon Suspension Clamp Type HSC……………………….. Page 77
Cast Iron Suspension Clamp Type DSC…………….………… Page 78
Cast Iron Trunnion Support Clamp Type DTSC……………………… Page 79
Aluminium Strain Clamp Type ATC…………….………… Page 80
Cast Iron Strain Clamp Type DTC……….……………… Page 81
STRAIN AND SUSPENSION CLAMPS

ALUMINIUM SUSPENSION CLAMP ////


PRODUCT
////
CATEGORY
E
SECTION
PAGE 74

Clamp Rated Dimensions, mm Approx.


Catalogue Range Strength Weight
Number mm kN kg
A B C D

ASC-5085 5 ~ 8.5 36 178 17.5 54 12 1.2

ASC-71130 7.1 ~ 13.0 36 190 18 54 12 1.4


B

ASC-100210 10.0 ~ 21.0 70 200 24 70 12 1.5

16 ASC-178235 17.8 ~ 23.5 36 226 28 74 12 2.3


C

ASC-230320 23.0 ~ 32.0 60 262 35 87 12 3.1


A
ASC-250350 25.0 ~ 35.0 60 262 38 87 12 3.5
A D
ASC-270390 27.0 ~ 39.0 70 230 40 54 12 3.9

ASC-280412 28.0 ~ 41.2 70 241 43 78 12 4.5

Dulhunty Power Aluminium Suspension Clamps are


ASC-356518 35.6 ~ 51.8 70 267 54 95 12 4.8
designed for use with AAC, AAAC and ACSR in
suspension applications for deviation angles of up to
20 deg. ASC-445572 44.5 ~ 57.2 70 280 58.7 95 16 5.1

Material:
Body and Keeper - Aluminium alloy
Hardware -Galvanized steel
Split Pin - Stainless steel
STRAIN AND SUSPENSION CLAMPS

ALUMINIUM PIVOT SUSPENSION CLAMP ////


////
CATEGORY

PRODUCT
E
SECTION
PAGE 75

Dulhunty Power Aluminium Pivot


Suspension Clamps are designed for use
with AAC,AAAC and ACSR in
suspensionapplications for deviation
angles of up to
20 deg.

Material:
Body and Keeper - Aluminium alloy
Hardware -Galvanized steel
Split Pin - Stainless steel

Clamp Rated Dimensions, mm Approx.


Catalogue Range Strength Weight
Number mm kN kg
A B C φ

PSC-9-19 9.5 ~ 19 80 180 40 90 16 2.5

PSC-18-30 18.0 ~ 30.0 120 217 50 116 16 3.0

PSC-30-45 30.0 ~ 45.0 120 267 68 120 16 4.0


STRAIN AND SUSPENSION CLAMPS

ALUMINIUM TRUNNION SUPPORT CLAMP ////


////
CATEGORY

PRODUCT
E
SECTION
PAGE 76

Dulhunty Power Trunnion Support Clamps are designed for


use with AAC, AAAC and ACSR conductors and supported
on horizontal or vertical line post insulators.

Reversible keeper allows a large conductor range for each


clamp size.

Material:
Body and Keeper - Aluminium alloy

Clamp Rated Dimensions, mm Approx.


Catalogue Range Strength Weight
Number mm kN L W Bolt size kg

TSC-0614 6 ~ 14 12 133 99 M12 0.5


TSC-0921 9 ~ 21 12 133 99 M12 0.5

TSC-1327 13 ~ 27 12 133 99 M12 0.6

TSC-2538 25 ~ 38 12 133 99 M12 0.6


STRAIN AND SUSPENSION CLAMPS

HELIXON SUSPENSION CLAMP ////


PRODUCT
////
CATEGORY
E
SECTION
PAGE 77

Conductors
Catalogue O.D. Colour
Number Code
AAC/
AAAC ACSR
6/1/3.00
HSC-09.00 7/3.00 9.00 Red
4/3/3.00
Insert
6/1/3.75
HSC-11.25 7/3.75 11.25 Black
4/3/3.75

HSC housing HSC-13.50 7/4.50 – 13.50 Green


HSC-14.30 7/4.75 6/1/4.75 14.30 Blue
HSC-16.25 19/3.25 – 16.25 Orange
HSC-17.50 – 30/7/2.50 17.50 Blue
Helixon suspension clamp rods
HSC-18.75 19/3.75 – 18.75 Black
HSC-21.00 37/3.00 30/7/3.00 21.00 Red
HSC-23.75 19/4.75 – 23.75 Blue

Dulhunty Power Helixon Suspension Clamps are designed for


use with AAC, AAAC and ACSR conductors and offer superior
vibration protection in severe vibration conditions.

Please consult our sales office for DHSC


STRAIN AND SUSPENSION CLAMPS

CAST IRON SUSPENSION CLAMP ////


PRODUCT
////
CATEGORY
E
SECTION
PAGE 78

Dulhunty Power Suspension Clamps are


designed for use with SC/GZ, SC/AC and
other steel conductors in suspension
applications.

Material:
Body and Keeper - galvanized cast iron
Hardware - galvanized steel
Split Pin - stainless steel

DSCO-0615 Offset clamp

Clamp Rated Dimensions, mm Approx.


Catalogue Range Strength Weight
Number mm kN L H kg

DSC-5085 5 ~ 8.5 50 178 54 2.0

DSC-71130 7.1 ~ 13.0 50 190 54 2.4

DSC-110185 11.0 ~ 18.5 50 180 53 3.1

DSC-178235 17.8 ~ 23.5 50 226 74 3.8

DSC-230320 23.0 ~ 32.0 60 262 87 4.9

DSCO-0615 6.0 ~ 15.0 24 152 79 1.8


STRAIN AND SUSPENSION CLAMPS

CAST IRON TRUNNION SUPPORT CLAMP ////


////
CATEGORY

PRODUCT
E
SECTION
PAGE 79

Dulhunty Power Trunnion Support Clamps are designed for


use with SC/GZ, SC/AC and other steel conductors in
suspension Applications.

Reversible keeper allows a large conductor range for each


clamp size.

Material:
Body and Keeper - galvanized cast iron

Clamp Rated Dimensions, mm Approx.


Catalogue Range Strength Weight
Number mm kN L W Bolt size kg

DTSC-0614 6 ~ 14 12 133 98.5 12 1.1


DTSC-1327 13 ~ 27 12 133 98.5 12 1.2

DTSC-2538 25 ~ 38 12 133 98.5 12 1.3


STRAIN AND SUSPENSION CLAMPS

ALUMINIUM STRAIN CLAMP ////


////
CATEGORY

PRODUCT
E
SECTION
PAGE 80

B Dulhunty Power Strain Clamps are designed


A for use with AAC, AAAC or ACSR conductor.

E
Material:
Body and Keeper - Aluminium alloy
D Hardware - Galvanized steel
C
Split pin - Stainless steel

Catalogue Clamp Rated Dimensions, mm U-Bolts Approx.


Number Range Strength Weight,
mm kN A B C D E NO. Size, kg
mm

ATC-51114 5.1 ~ 11.4 40 108 19 126 20 16 2 12 0.5

ATC-89185 8.9 ~ 18.5 40 187 24 176 32 16 2 12 1.8

ATC-50150 5.0 ~ 15.0 70 203 17.5 190 20 16 3 12 1.9

ATC-121218 12.1 ~ 21.8 70 284 30 298 32 16 4 12 4.1

ATC-180300 18.0 ~ 30.0 70 342 36 446 38 20 5 12 7.0


STRAIN AND SUSPENSION CLAMPS

CAST IRON STRAIN CLAMP ////


////
CATEGORY

PRODUCT
E
SECTION
PAGE 81

Dulhunty Power Strain Clamps are


B
A
designed for use with SC/GZ, SC/AC and
other steel conductors in suspension
applications.
D

Material:
Body and Keeper - Galvanized cast iron
Hardware - Galvanized steel
C
Split pin - Stainless steel

Catalogue Clamp Rated Dimensions, mm U-Bolts Approx.


Number Range Strength Weight,
mm kN A B C D NO. Size, kg
mm

DTC-510 5.0 ~ 10.0 20 120 18 150 16 2 12 1.3

DTC-1014 10.1 ~ 14.0 40 130 18 205 16 3 12 2.1

DTC-1418 14.1 ~ 18.0 70 160 22 310 18 4 16 4.6

DTC-1823 18.1 ~ 23.0 90 220 25 410 18 4 16 7.1


FABRICATED FITTINGS

INDEX ////
////
CATEGORY

PRODUCT
F
SECTION
PAGE 82

Shackle Straps Type S-STRAP……………….. Page 83


"U" Shackle Straps Type S-STRAP….. …………… Page 84
Cross Arm Brace Type X-BRACE… .….. ………. Page 85
Stay Rods and Bows Type STAY…...….. .…………… Page 86
Saglinks Type SL …………………………. Page 87
Yoke Plates Type YPT ……… ….…. ………. Page 88
Maintenance Tension Link Type MTL ……… ….…. ………. Page 89
Link Plates Type LP & DLP…………………. Page 90
Double Arming Bolts Type DAB………………………. Page 91
Guy Thimble Closed Type GT……….….……. ………. Page 92
Guy Thimble Opened Type OGT…….…….….. ……….Page 92
Eye Bolt Type EB………..….…… ………. Page 93
Pole Steps Type PS…………………………. Page 94
Line Pins and Hooks Type …………...….…… ………. Page 95
FABRICATED FITTINGS

SHACKLE STRAP ////


PRODUCT
////
CATEGORY
F
SECTION
PAGE 83

Material:
Galvanized Steel

Catalogue Dimension, mm Approx.


Number Weight
A B D W T L
kg
S-STRAP-1 17 17 14 32 5 216 0.6

S-STRAP-3 22 22 16 50 6 316 0.8

S-STRAP-4 25 25 18 32 5 250 0.6

S-STRAP-5 25 25 16 32 5 250 0.6

S-STRAP-8 25 25 18 40 6 255 0.7


FABRICATED FITTINGS

“U” SHACKLE STRAP ////


////
CATEGORY

PRODUCT
F
SECTION
PAGE 84

Material:
Galvanized Steel

Catalogue Dimension, mm Approx.


Number Weight
A B D1 D2 W T L kg

S-STRAP-2 22 92 16 18 40 6 130 0.6

S-STRAP-7 22 117 16 18 40 6 111 0.6


FABRICATED FITTINGS

CROSS ARM BRACE ////


PRODUCT
////
CATEGORY
F
SECTION
PAGE 85

Material:
Galvanized Steel

Catalogue Dimension, mm Approx.


Number Weight
A B D W T L
kg
X-BRACE-01 25 25 18 40 6 863 1.9

X-BRACE-02 25 25 18 50 6 863 2.1

X-BRACE-03 25 25 18 50 6 800 2.0

X-BRACE-04 25 25 18 50 6 500 1.3


FABRICATED FITTINGS

STAY ROD AND BOW ////


////
CATEGORY

PRODUCT
F
SECTION
PAGE 86

Material: Galvanized Steel

Catalogue Dimension, mm Approx.


Number Weight
kg
A B H L

STA-PNG-1 20 16 355 2745 10.5

STA-PNG-2 24 20 355 3200 13.5

STAY- 1 20 16 355 2500 11.5

STAY- 2 16 16 355 2000 10.0

STAY -3 24 20 550 4500 20.0


STA-PNG-1 STAY- 4 24 24 355 2400 10.5
STA-PNG-2
STAY-2 STAY-1
STAY-4 STAY-3
FABRICATED FITTINGS

SAGLINK ////
////
CATEGORY

PRODUCT
F
SECTION
PAGE 87

Material:
Galvanized Steel

Catalogue Minimum Dimension, mm Approx.


Number Failing Weight
Load A B T L kg
kN max

SL-70-485 70 19 19 8 485~745 7.0

SL-70-230 70 19 19 8 230~350 6.0

SL-120-566 120 18 20 8 566~974 9.0

SL-160-566 160 22 24 10 566~974 11.0


FABRICATED FITTINGS

YOKE PLATE ////


PRODUCT
////
CATEGORY
F
SECTION
PAGE 88

Material:
Galvanized Steel

Consult Dulhunty Power for yoke plates to suit any string arrangement

Catalogue Minimum Dimension, mm Approx.


Number Failing Weight
Load A H φ W R1 R2 kg
kN
YPT-70-560 70 16 100 18 560 22 22 5.0

YPT-70-457 70 16 100 18 457 22 22 4.5

YPT-120-457 120 16 100 18 457 22 22 4.5

YPT-160-380 160 20 76 22 380 28 28 5.5


FABRICATED FITTINGS

MAINTENANCE TENSION LINK ////


////
CATEGORY

PRODUCT
F
SECTION
PAGE 89

Material:
Galvanized Steel

Catalogue Minimum Dimension, mm Approx.


Number Failing Weight
Load L1 L2 L3 W R φ kg
kN
MTL-70 70 60 60 60 16 22 18 0.7

MTL-160 160 60 60 60 20 25 22 0.9


DOUBLE AND SINGLE LINK PLATES
FABRICATED FITTINGS

////
PRODUCT
////
CATEGORY
F
SECTION
PAGE 90

Link plates are available in 70/120/160 kN


ratings and various lengths.

Please refer to our nearest sales office for


further information.

Material:
Body - Galvanized steel
Hardware - Galvanized steel
Single link plate Link Plate Assembly Split pin - Stainless steel

Consult Dulhunty Power for link plates to suit any string arrangement

Catalogue Catalogue Hole Center Distance


Number Number mm
Double Plate Links Single Plate Links
DLP-70-100 LP-70-100 100

DLP-70-150 LP-70-150 150

DLP-70-200 LP-70-200 200

DLP-70-250 LP-70-250 250

DLP-70-300 LP-70-300 300

DLP-70-350 LP-70-350 350


FABRICATED FITTINGS

DOUBLE ARMING BOLTS ////


////
CATEGORY

PRODUCT
F
SECTION
PAGE 91

Material: Galvanized Steel

Catalogue Dimension,mm
Number
Overall Thread φ
Length length
DAB20-400 400 150

DAB20-450 450 200

DAB20-500 500 200

DAB20-550 550 20

DAB20-600 600
250
DAB20-650 650

DAB20-700 700
FABRICATED FITTINGS

GUY THIMBLE ////


////
CATEGORY

PRODUCT
F
SECTION
PAGE 92

Material: Galvanized Steel

Catalogue Dimension, mm Approx. Catalogue Dimension, mm Approx.


Number Weight Number Weight
C D G A T S D H B T
Per 100 Per 100
Nom. kg
kg

GT-10 41 37 24 10.5 2 2.6 OGT-10 12 28 43 11 1.75 1.7


GT-12 48 45 29 13.5 2.5 5.2 OGT-12 14 30 50 13 2 3.2
GT-16 57 60 35 17 3 10.5 OGT-16 18 36 59 18 3 6.4
GT-20 63.5 68 41.5 20 3 21.0 OGT-20 22 47 70 21 2.5 13.0
GT-22 89 81 48 24 3.2 35.7 OGT-25 25 65 92 23 8 13.0
FABRICATED FITTINGS

EYE BOLT ////


////
CATEGORY

PRODUCT
F
SECTION
PAGE 93

Material:
Galvanized Steel

Catalogue Dimension, mm Approx. Catalogue Dimension, mm Approx.


Number L M D φ Weight Number L M D φ Weight
kg kg
EB16-150 150 0.4 EB20-150 150 0.6
EB16-200 200 0.5 EB20-200 200 0.8
EB16-250 250 0.6 EB20-250 250 0.9
EB16-300 300 0.7 EB20-300 300 1.0
16 38 16 20 38 20
EB16-350 350 0.7 EB20-350 350 1.2
EB16-400 400 0.8 EB20-400 400 1.3
EB16-450 450 0.9 EB20-450 450 1.5
EB16-500 500 1.0 EB20-500 500 1.6
EB16-600 600 1.2 EB20-600 600 1.7
FABRICATED FITTINGS

POLE STEPS ////


////
CATEGORY

PRODUCT
F
SECTION
PAGE 94

Catalogue Catalogue
Number Number
PS16-250 PS16-250-S

Knock in style Screw in style

Material: Galvanized Steel


FABRICATED FITTINGS

LINE PINS AND HOOKS ////


////
CATEGORY

PRODUCT
F
SECTION
PAGE 95

Catalogue number
Catalogue number COM-HOOK Catalogue number
FUSE-PIN M12 x 150mm PIG-HOOK
M12 x 150mm Pattern B head 16mm Ball
Pattern B head

Catalogue number
PIG-TAIL
M8 x 145mm

Catalogue number Catalogue number


J-HOOK L-HOOK
M12 x 150mm M12 x 150mm
OTHER PRODUCTS

INDEX ////
////
CATEGORY

PRODUCT
G
SECTION
PAGE 96

Heat Shrink Products ………………………………………………. Page 97 - 99 106 - 109


Resin Filled Products ……………………………………………… Page 100 - 101
Fibreglass Cabinets……………………………… ……………….. Page 102 - 103
Residential Pillars and Bases ……………………………………. Page 104 - 105
Transformer Shrouds………………………………………………. Page 110
Low Voltage Switches ………………………………………………Page 111
Drop Out Fuses…………………………………..………………… Page 112
Fuses………………………………………………..………………… Page 113
Linesman Equipment ………………………………………………. Page 114 - 123
Earthing Equipment………………………………………………… Page 123 - 124
Surge Arrestors………..……………………………………………. Page 125
Warning Markers……………………………………………………. Page 126
Measuring Meters…………………………………………………… Page 127 – 131
PLS-Cadd Software………………………………………………… Page 132 - 133
Corona Camera……………………………..……………………….. Page 134
Sagometer…….……………………………..……………………….. Page 135
Fault Indicators……………….………………………………………Page 136 – 141
Cat-1………..…………………………………………………………. Page 142
Polly-mar Shrouds……………..……..…………………………… Page 143
Emergency Towers……….…………………………………………. Page 144
Air break switches………………………………………..…….…… Page 145
Automatic Deadends and Splices………………………….…….. Page 146 - 151
G
OTHER PRODUCTS ////
CABLE JOINT PRODUCTS CATEGORY

HEATSHRINK PRODUCTS ////


PRODUCT
SECTION
PAGE 97

Breakouts Insulating tape Right angle boots Sealing caps

HV Inline joints LV Inline joint Termination kits Wrap around's


G
OTHER PRODUCTS ////
CABLE JOINT PRODUCTS CATEGORY

HEATSHRINK PRODUCTS ////


PRODUCT
SECTION
PAGE 98

High Voltage In-line Joint 22kV Single Core

SPECIALISING IN
HV TERMINATION KITS
INDOOR AND OUTDOOR

FROM - 3.3kV TO 36kV

Please refer to our nearest sales office for further information


G
OTHER PRODUCTS ////
CABLE JOINT PRODUCTS CATEGORY

SELECTION CHARTS ////


PRODUCT
SECTION
PAGE 99

TERMINATIONS AND INLINE JOINTS

HVT Termination for XLPE and Paper cables HVJ injoint for XLPE and Paper cables

Please refer to our nearest sales office for further information


G
OTHER PRODUCTS ////
CABLE JOINT PRODUCTS CATEGORY

RESIN FILLED PRODUCTS ////


PRODUCT
SECTION
PAGE 100

Fully Tested
Designed to meet requirements of BS6910 and CENELEC HD623 S1.

Straight through and Branch Joints up to 300 sq mm


All standard joints are supplied as a complete kit in a single carton. Each kit comprises a clear plastic shell,
armour bond, a two-part polyurethane resin compound, gloves and jointing instructions.

Connectors
Joint kits can also be available with mechanical connectors or crimp sleeves.

No special jointing skills


Jointing is easy. Instructions are provided with each joint.

Working space
There is a choice of snap-lock shell or larger shell to provide even more working space.

No heat
Joints are filled with a two part high quality polyurethane resin compound which is supplied in a two-section
self contained, non perishable bag enclosing both resin and hardener ensuring there is no contact with skin.

No further protection
The resin compound completely penetrates and sets solid within a plastic shell which effectively insulates,
seals and protects the joint. It will not subsequently soften.

Shelf life.
Shelf life of the resin is 2 years when stored in well ventilated dry conditions between 10 – 25 degrees.

Range of joints
600-1000V cables with stranded copper or solid aluminium conductors up to 300sqmm PVC, XLPE of EPR
insulated, PILC,PVC sheathed single wire armoured, aluminium strip armour or unarmoured.
G
OTHER PRODUCTS ////
CABLE JOINT PRODUCTS CATEGORY

RESIN FILLED PRODUCTS ////


PRODUCT
SECTION
PAGE 101

B D
C

Straight through joint Tap off joint

Catalogue Dimension, mm Approx. Catalogue Dimension, mm Approx.


Number resin Number resin
A B C D E
content content
L D C
CJS-MB6 (OY) 155 45 7 30 130 200ml
CJS-STRAIGHT 6 189 40 6 - 28 200ml
CJS-MB16 235 75 15 25 170 1 litre
CJS-STRAIGHT 16 275 50 12 - 32 450 ml
CJS-MB35 360 100 15 30 230 2 litre
CJS-STRAIGHT 3570 355 72 26 - 45 1.5 litre
CJS-MB70 390 120 15 40 240 4 litre
CJS-STRAIGHT 120 547 108 37 - 67 4 litre
CJS-MB120 570 160 15 50 410 10 litre
CJS-STRAIGHT 185 800 132 48 - 88 10 litre
CJS-MB185 680 190 58 58 520 18 litre

CJS-MB300 740 250 45 75 620 26 litre

Recommendation
We recommend that all resin kits are installed on de-energized cables.
The resin kits detailed should only be installed by suitably qualified people.
G
OTHER PRODUCTS ////
CABLE PRODUCTS CATEGORY

LV AND HV FIBREGLASS CABINETS ////


PRODUCT
SECTION
PAGE 102

Catalogue Description Size (mm) Colour


Number
FPB10105V1D Fibreglass Cabinet Vented Single 1000Wx1000Hx500mmD Green/Beige
Door
FB-105 Fibreglass Base to match 1000Wx300Hx500mmD Green/Beige

FPB10127V1D Fibreglass Cabinet Vented Single 1000Wx1200Hx700mmD Green/Beige


Door
FB-107 Fibreglass Base to match 1000Wx300Hx700mmD Green/Beige

FPB13125V1D Fibreglass Cabinet Vented Single 1300Wx1200Hx500mmD Green/Beige


Door

FB-135 Fibreglass Base to match 1300Wx300Hx500mmD Green/Beige

FPB13127V1D Fibreglass Cabinet Vented Single 1300Wx1200Hx700mmD Green/Beige


Door

FB-137 Fibreglass Glass Base to match 1300Wx300Hx700mmD Green/Beige

FPB151275V1D Fibreglass Cabinet Vented Single 1500Wx1200Hx750mmD Green/Beige


Door

FB-1575 Fibreglass Base to match 1500Wx300Hx750mmD Green/Beige


G
OTHER PRODUCTS ////
CABLE JOINT PRODUCTS CATEGORY

COMMERCIAL FIBREGLASS CABINETS ////


PRODUCT
SECTION
PAGE 103

Catalogue Description Size (mm) Colour Kg


Number

FPBNF1V Fibreglass Pillar Vented 760Hx450Wx330D Beige/Green 7

FPBNF1V1D Fibreglass Pillar Vented 760Hx450Wx330D Beige/Green 8


Single Door

FPBNF1V2D Fibreglass Pillar Vented 760Hx450Wx330D Beige/Green 9


Two Door

FBNF1 Fibreglass Bass 310Hx565Wx335D Beige/Green 3.5

GSFPNF1 Type X S/Panel 700Hx420Wx10Thk Black 5


Blank/Frame Assy

PSFB2 Security Bolts/Washers 4 Per Pillar G304 S/Stl

SLP-1 Locking Plate suit Padlock 1 Per Pillar G304 S/Stl

SLB-1 Locking Bolt suit SLP-1 1 Per Pillar G304 S/Stl


G
OTHER PRODUCTS ////
CABLE JOINT PRODUCTS CATEGORY

UNDERGROUND RESIDENTIAL PILLARS ////


PRODUCT
SECTION
PAGE 104

Wall Thickness
4mm min

Flame Retardancy
750 Degrees C Min (AS2420 AppB)

Material:
Polypropylene copolymer with additive
rubberiser

Dimensions
Dimensions of the URPL and the URPLV
are as shown.
Cat No:URPL

Catalogue Description Wall


Number Thickness

URPS Underground Residential Pillar Small 4mm Min

URPSV Underground Residential Pillar Small Vented 4mm Min

URPL Underground Residential Pillar Large 4mm Min

URPLV Underground Residential Pillar Large Vented 4mm Min


G
OTHER PRODUCTS ////
CABLE JOINT PRODUCTS CATEGORY

RESIDENTIAL PILLAR BASE ////


PRODUCT
SECTION
PAGE 105

Wall Thickness
4mm min

Flame Retardancy
750 Degrees C Min (AS2420 AppB)

Material:
URPB Polypropylene copolymer with additive rubberiser

IP Rating:
IP44 (Attached to Dulhunty Base)

Catalogue Number Description Pack Size

URPB Underground Residential Pillar Each


Base

URAB Underground Residential Allen 4


Bolt

URDB Underground Residential “D” 4


Head Bolt

URTS Underground Residential Tube Each


Spanner

URAB URTS

Please contact our sales office for more details on our range of Fuse Panels
G
OTHER PRODUCTS ////
HEATSHRINK BOOTS CATEGORY

2 WAY LV CABLE BREAK OUT BOOT ////


PRODUCT
SECTION
PAGE 106

Catalogue D d P F TB TF
Number
S S
E S E S E S E S
MAX MAX
LVCBR250 24 12 9 4.5 90 90 30 28 1.5 1.5

LVCBR260 60 22 25 7 110 120 35 40 3 3


LVCBR275 75 45 35 15 140 140 50 50 2 2
G
OTHER PRODUCTS ////
HEATSHRINK BOOTS CATEGORY

3 WAY LV CABLE BREAK OUT BOOTS ////


PRODUCT
SECTION
PAGE 107

Catalogue D d P F TB TF
Number
S S
E S E S E S E S
MAX MAX
LVCBR0413 37 13 14 4 85 117 18 31 2.2 2.4

LVCBR0820 50 21 22 9 135 170 31 50 3.5 2.2

LVCBR1330 75 31 32 14 160 210 40 60 3.5 2.2

LVCBR2145 110 46 52 22 160 210 40 60 3.8 2.5

LVCBR2755 135 56 64 28 230 210 40 65 3.8 2.8


G
OTHER PRODUCTS ////
HEATSHRINK BOOTS CATEGORY

4 WAY LV CABLE BREAK OUT BOOTS ////


PRODUCT
SECTION
PAGE 108

Catalogue D d P F TB TF
Number
S S
E S E S E S E S
MAX MAX
LVCBR0415 35 16 12 5 85 105 14 20 2.3 1.4

LVCBR0925 60 26 22 10 170 220 30 46 3.6 2.5

LVCBR1334 90 35 34 14 170 220 30 48 3.3 2.5

LVCBR2454 120 55 50 25 200 250 50 65 4.2 3.3


G
OTHER PRODUCTS ////
HEATSHRINK END CAPS CATEGORY

LOW VOLTAGE HEARTSHIRNK END CAPS ////


PRODUCT
SECTION
PAGE 109

Catalogue H H L W
Number
EXP MIN REC MAX EXP MIN REC NOM

EC-001 14 4.5 50 1.2

EC-101 25 8 65 3.0

EC-201 35 15 90 3.0

EC-301 55 25 110 4.0

EC-401 75 35 120 4.2

EC-501 100 50 130 4.2

EC-601 120 60 140 4.2

EC-701 145 71 155 4.6

EC-701U 145 71 155 4.6


G
OTHER PRODUCTS ////
CABLE PRODUCTS CATEGORY

TRANSFORMER SHROUDS ////


PRODUCT
SECTION
PAGE 110

Transformer Shroud 22kV Large Transformer Shroud 11kV Small


P/N YAA833AA025 P/N YAA833AA004
LOW VOLTAGE SWITCHES

LOW VOLTAGE SWITCHES ////


////
CATEGORY

PRODUCT
G
SECTION
PAGE 111

LVI LVFI

CATALOGUE TYPE RATED RATED RATED RATED RATED CLEARANCE


No. SHORT- VOLTAGE CURRENT MAKING BREAKING TO EARTH
TIME (Uе)V (Ie)AMP CAPACITY CAPACITY mm.
CURRENT I/Ie Ic/Ie
NZ4284SECV LVI 20kA 480 630 1 1 32

NZ4284SEQEB LVI 20kA 480 630 1 1 32

NZ4298 LVI 36kA 480 800 1 1 32

NZ4296SECV LVI 36kA 480 1600 - - 32

NZ4239SECV LVFI 20kA 480 400 1 1 32

NZ4239A LVFI 20kA 480 400 1 1 32

NZ4286SECV LVFI 20kA 480 630 1 1 32


OTHER PRODUCTS

DROPOUT FUSES ////


////
CATEGORY

PRODUCT
G
SECTION
PAGE 112

STANDARD BASE UNITS

Part no. Rated Rate current Rated Breaking BIL Clearance Dry Arcing
Voltage (In) amp Capacity kV to Earth Distance
(U)kV Ka (sym) mm mm

72298/15 12/24 100 8/6 150 475 215

72299/27 24/36 100 6/4 170 660 260


OTHER PRODUCTS

FUSES ////
PRODUCT
////
CATEGORY
G
SECTION
PAGE 113

Catalogue Type K speed characteristics Catalogue Amps


Number Number
Amps D B Washer
SWE-ME-NB005 5
ZXC705-01BK37 1 7.9 12.7 Yes

ZXC705-02BK37 2 7.9 12.7 Yes SWE-ME-NB010 10

ZXC705-03BK37 3 7.9 12.7 Yes


SWE-ME-NB015 15
ZXC705-06BK37 5&6 7.9 12.7 Yes
SWE-ME-NB020 20
ZXC705-08BK37 8 7.9 12.7 Yes

ZXC705-010BK37 10 7.9 12.7 Yes SWE-ME-NB025 25

ZXC705-012BK37 12 7.9 12.7 Yes SWE-ME-NB030 30


ZXC705-016BK37 16 7.9 12.7 Yes
SWE-ME-NB040 40
ZXC705-020BK37 20 7.9 12.7 Yes
SWE-ME-NB045 45
ZXC705-025BK37 25 7.9 12.7 Yes

ZXC705-030BK37 30 7.9 12.7 Yes SWE-ME-NB050 50

ZXC705-040BK37 40 7.9 12.7 Yes House service fuse SWE-ME-NB060 60


ZXC705-050BK37 50 7.9 12.7 Yes
Rated at 63 amp
Single spring P/N SF100B SWE-ME-NB080 80
ZXC705-063BK37 63 10.9 19 No
Double spring P/N SF100A
ZXC705-080BK37 80 10.9 19 No SWE-ME-NB100 100

ZXC705-100BK37 100 10.9 19 No


G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

TOOLS ////
PRODUCT
SECTION
PAGE 114

Electrical Insulating Gloves


Natural latex in 500V, 1000V, 7500V
Pole Bucket – Large 17000V and 26500V
Reinforced bottom
heavy duty canvas Outer Protection Gloves
2 pockets Goat, Sheep and Kangaroo leather to be
Safety Belts Full Harness
300x300mm worn over Class 00 gloves
P/N AB004 P/N AB10A P/N PB-SIL-0021 Cowhide to be worn over Class 2,3,4 and 7 gloves

Canvas bag
Zipper top
Pole strap
550x300x300 P/N AF725AU – 2.5 meters
P/N CLCT24 AF735AU – 3.5 meters
Tool pouch
P/N B-TPSFEA

Belt and tools not included


G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

TOOLS ////
PRODUCT
SECTION
PAGE 115

P/N ABC13-17 P/N SB-3 Aluminium - White P/N HES50.240


P/N Modiewark
Ratchet Spanner SB-4 Copper – Black Cable stripper 50 – 240sqmm
Scratch Brush

P/N PP-1 P/N AC3920 P/N AV6410


Pole platform – wooden pole Knife & scabbard IC semicon tool
G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

COMEALONG CLAMPS ////


PRODUCT
SECTION
PAGE 116

Catalogue Number MGV4 Catalogue Number MGV6

Max Safe Work Limit 20kN (2.0T) Max Safe Work Limit 20kN (2.0T)

Cable Dia. Range 4mm ~ 20mm Cable Dia. Range 5mm ~ 25mm

Jaw length 62mm Jaw length 114mm

For use on Copper,Steel For use on Aluminium and


conductor, wire rope Covered Conductor

Weight 1.4kg Weight 2.2kg

Safety latch and large eye lever Safety latch and large eye lever

Catalogue Number MGV5

Max Safe Work Limit 20kN (2.0T) Catalogue Number ABC495

Cable Dia. Range 5mm ~ 25mm Max Safe Work Limit 20kN (2.0T)

Jaw length 114mm Cable Dia. Range 4 x 95sqmm

For use on Copper,Steel Jaw length 190mm


conductor, wire rope
For use on LV ABC
Weight 2.2kg
Weight 5kg
Safety latch and large eye lever
G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

LUG ALL ////


PRODUCT
SECTION
PAGE 117

WIRE ROPE MODELS

Catalogue Load Frame Approx.


Number Capacity Size Weight
kgs kgs

1000-15 ANZ 750 small 3.2


1000-15 PS ANZ

1500-25 ANZ 680 small 3.9


1500-25 PS ANZ

2250-20 ANZ 1020 small 4.2


2250-20 PSANZ

3000-10 ANZ 1360 small 4.2


3000-10 PS ANZ

2250-38 ANZ 1020 medium 6.2


2250-38 PS ANZ

3000-30 ANZ 1360 medium 6.2


3000-30 PS ANZ

4000-20 ANZ 1815 medium 7.0


4000-20

WEB STRAP MODELS

Catalogue Load Approx.


Number Capacity Weight Note:
kgs kgs All web strapped
models come
2-A-1300 910 4.6 complete with a
3-A-1300 1360 5.9 carry bag

4-A-1300 1815 6.7


G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

LINDSAY UNIVERSAL STRINGING ROLLER ////


PRODUCT
SECTION
PAGE 118

Part number CSR5930


Roller

Part number CSR 5900


adaptor

Maximum diameter of Safe working Roller Combined


conductor or splice load suspended weight Roller weight
or mounted 5930 5930 & 5900

50mm 11 kN 3.8 kg 5.2 kg

90 deg. 67.5 deg. 45 deg. 22.5 deg.


G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

CABLE STRINGING ROLLER ////


PRODUCT
SECTION
PAGE 119

Catalogue Suitable for Approx.


Number Crossarm Rollers Weight
mm kg

CSR-4 100 Nylon 2.3

CSR-5 150 Nylon 2.7


G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

HASTINGS ////
PRODUCT
SECTION
PAGE 120

Telescopic Hot Sticks

TRIANGLE SHAPE – Enables each section to “Lock in automatically.” No more twisting and turning to lock
sections.

HIGH VISIBILTY – Fluorescent tips section is highly visible and has a foam core. All tips sections are 1.15”
diameter. All sections are 100% tested per OSHA and ASTM F-711.

EXTRA REACH- New 40’ model now available.

RE-DESIGNED LOCK BUTTONS- New shape and large size are easier to operate with and without gloves.

MORE VERSATILE- Use only the number of required sections to perform each job, Example: A 40 FT.
(12.2 Meters) tool can be reduced to a 20ft. (6.1 Meters) working height by depressing the lock button and sliding
the bottom sections off. This allows for a lightweight tool to perform the work easier.

EASY DISASSEMBLY- Simply depress the lock button and slide section, or sections, out. No tools are required
for disassembly.
P10060 ERGONOMIC DESIGN- Gives the operator a “better gripping” surface for better control.

REDUCES INVENTORY- Only one size lock button and spring for replacement needs.

EASY MAINTENANCE- All sections have a smooth glossy surface for routine cleaning and waxing.

NEW BASE CAP- Cushions and protects base end.


Locking button
IMPROVED UNIVERSAL HEAD- Strong Aluminium alloy head incorporates corona discharge design and Side view LVP-1
“includes a captive Belleville washer” to hold universal attachments securely.

P30142

End view showing Catalogue Extended Retracted Weight


triangular shape Number Length Length
Nominal Nominal

HV-208 2.4 m 0.67 m 1.4

HV-212 3.8 m 1.48 m, 1.6

HV-216 5.0 m 1.53 m 2.2

HV-220 6.4 m 1.58 m 2.9

HV-225 7.8 m 1.63 m 3.6


Note.
All telescopic hot HV-230 9.2 m 1.68 m 4.5
P10044 sticks come complete
with a carry bag HV-235 10.6 m 1.72 m 5.5
3550
HV-240 12.0 m 1.75 m 6.5
G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

CABLE CUTTERS ////


PRODUCT
SECTION
PAGE 121

P/N CC705 P/N 7116A


P/N REL-9009 Cable cutter Ratchet Cutter Compact
Ratchet Cutter Compact Copper up to 20mm diameter. Up to25mm diameter ACSR
Up to 20mm diameter ACSR Aluminium up to 28mm diameter. Up to 32mm diameter Alum

P/N RC7118
Ratchet Cutter Compact
Up to25mm diameter ACSR
Up to 28mm diameter Alum

P/N S200
Standard Guy Wire, Ground Rod, Rebar: 20 mm
Capacity Aluminiumium and Copper Cable, ACSR: 20 mm
Soft Steel Bolts: 20 mm
Wire Rope: 20 mm
G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

COMPRESSION TOOLS ////


PRODUCT
SECTION
PAGE 122

P/N REC-H130
Force at die face 120kN
Battery operated

P/N EP-100W
P/N EP-510B Force at die face 100kN
Force at die face12 ton

P/N EP-50 P/N EPH-130H


Force at die face 5.2 ton P/N P-60 Force at die face120kN
Cuts Aluminium or copper cable
up to 60mm diameter
G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

EARTH SETS ////


PRODUCT
SECTION
PAGE 123

The PIMT style earth sets consist of a single extendable


fiberglass earth stick, which can be removed.
Part number
PIMT-1 The PIMT earth sets can be supplied with earth rods.

The PIMT earth sets are supplied in a canvas carry bag.

PIMT-1 PIMT-2

PIMT-3

Please refer to our nearest sales office for further information


G
OTHER PRODUCTS ////
LINESMEN EQUIPMENT CATEGORY

EARTH RODS AND CLAMPS ////


PRODUCT
SECTION
PAGE 124

P/N ECP01 P/N EARTHCOMPOUND


P/N CER1314 11kg bags
12.7mm x 1400 Earth enhancing compound
Pointed Copper bonded Ground Rods Suitable for 26mm diameter pipe
Complete with brass clip 16 - 35sqmm cable range
Accepts 1 cable

P/N ECP1

Suitable for 34mm diameter pipe

P/N ECT10 16 – 35sqmm cable range


Accepts 2 cable

Suitable for 43mm diameter pipe


50 - 120sqmm cable range
Accepts 2 cable P/N ECB1

Suitable for 13-19mm diameter


16 – 35sqmm cable range
Accepts 1 cable

P/N ECB2
P/N CER1918
19 mm diameter x 1800mm Suitable for 13-19mm diameter P/N EC-210
Pointed Copper bonded Ground Rods
50 – 120sqmm cable range
Accepts 2 cable Suitable for 13-15mm diameter
16 - 120sqmm cable range
Accepts 1 cable
OTHER PRODUCTS

SURGE ARRESTOR ////


PRODUCT
////
CATEGORY
G
SECTION
PAGE 125

Catalogue
Rating Voltage Number Bracket

5kA 11kV SA11-05 No insulating brackets


5kA 11kV SA11-05-B Insulating bracket
5kA 22kV SA22-05 No insulating brackets
5kA 22kV SA22-05-B Insulating bracket

10kA 11kV SA11-10 No insulating brackets


10kA 11kV SA11-10-B Insulating bracket
10kA 22kV SA22-10 No insulating brackets
10kA 22kV SA22-10-B Insulating bracket
10kA 33kV SA33-10 No insulating brackets
10kA 33kV SA33-10-B Insulating bracket

P/N SAMB
Surge arrestor bracket
WARNING MARKERS
OTHER PRODUCTS

////
////
CATEGORY

PRODUCT
G
SECTION
PAGE 126

Live line marker ball 200mm


Marker ball 300 - 600mm
Material : High density polyethylene
Material : Fiberglass

Catalogue Diameter Colour


Number mm
Orange Red Yellow White

AWM-600-O 600 O

AWM-600-R 600 R

AWM-600-Y 600 Y

AWM-600-W 600 W

AWM-300-O 300 O

AWM-300-R 300 R

AWM-300-Y 300 Y

AWM-300-W 300 W
MEASURING METERS
OTHER PRODUCTS

////
///
PRODUCT
////
CATEGORY
G
SECTION
PAGE 127

IKE is a new category of Rapid


Survey GIS data capture device

•Visual re-inspection from back in the


office; Did that asset really need
repair/replacement?

•No confusion of which asset needs


maintenance.

•Ability to track how an asset’s


condition changes over time.

•Photo is tied to a spatial reference.

•IKE Sync desktop application comes


with IKE

•Transfers data and image files from


IKE, and performs DGPS post
processing

Please refer to our nearest sales office for further information


OTHER PRODUCTS

SUPARULE ////
////
CATEGORY

PRODUCT
G
SECTION
PAGE 128

SupaRule 600 SupaRule 600E Finest 707 Finest 850


OTHER PRODUCTS

SUPARULE ////
////
CATEGORY

PRODUCT
G
SECTION
PAGE 129

Model Users

SupaRule One Cable Height Meter <15m 190 Mining

SupaRule Cable Height Meter <15m 600 Distribution

SupaRule Cable Height Meter <23m 600E Transmission

SupaRule Railway Overhead Stagger meter 4<m<7 ROM Railways

Finest 707 707 Analysing complex electrical and


electronic circuits.
Finest 850 850 General electrical maintenance
e.g. portable appliance testing.
OTHER PRODUCTS

MEASURING METERS ////


PRODUCT
////
CATEGORY
G
SECTION
PAGE 130

Trupulse 200
Impulse XLR

Yardage Pro 1500 Yardage Pro 500 Tour XL


OTHER PRODUCTS

MEASURING METERS ////


////
CATEGORY

PRODUCT
G
SECTION
PAGE 131

Model Users

LTI Impulse XLR Range, bearing, inclination 200XLR Transmission

LTI Trupulse 200 range and inclination LT200 Distribution

LTI Yardage Pro 500 Tour XL Y500 Distribution

LTI Yardage Pro Elite 1500 Y1500 Transmission


OTHER PRODUCTS

PLS-CADD SOFTWARE ////


////
CATEGORY

PRODUCT
G
SECTION
PAGE 132
PLS-CADD SOFTWARE
OTHER PRODUCTS

////
////
CATEGORY

PRODUCT
G
SECTION
PAGE 133

PLS Lite Restricted version of PLS-CADD limited to the calculation of sags, tensions
/LOADS and structure loading trees.
PLS -Survey Restricted version of PLS-Cadd for surveyors and environmental display.

PLS-CADD Complete line design programme. (including SAGSEC, alignment,


Basic engineering and plotting modules but without automatic optimum spotting or
optional structure programmes).
PLS-CADD PLS-CADD above two items plus Optimum spotting option (but without
Optimum optional structure programmes).
SAPS Non-linear analysis of Power & Communication Systems.

TOWER Analysis and design of steel latticed tower.

PLS-GMAST Analysis & design of transmission structure with modular guyed masts.

PLS-CPOLE Analysis & design of prestressed concrete poles and frames.

PLS-WPOLE Analysis & design of wood poles and frames.

PLS-SPOLE Analysis & design of steel poles and frames.

CAISSON Design of reinforced concrete pier foundation for pole.


CORONA CAMERA
OTHER PRODUCTS

////
PRODUCT
////
CATEGORY
G
SECTION
PAGE 134

DayCor® Superb
Superb is a professional portable daytime corona and arcing detection device specially designed to enhance and streamline
maintenance tasks. Superb is a bi-spectral Solar Blind UV-Visible imager, designed to detect faint UV emissions in full
daytlight with high signal to background ratio. Its ergonomic design and powerful optics enable convenient and efficient
professional corona and arcing detection. Superb is reinforced with Ofil's reporting and analyzing software that offers flexible
customized professional reports.

DayCor® Classic
Classic is a professional daylight corona and arcing detection device ideal for high-voltage laboratories, research institutes,
classrooms, workshops, etc. Classic is a bi-spectral Solar Blind UV-Visible imager, designed to detect very faint UV
emissions in full daylight with high signal to background ratio. Its powerful optics and additional optional set of close-up lenses
ensure detailed view of inspected objects and reveal reliably existing discharge of corona and arcing. Classic comes with a
dedicated reporting and analyzing software with flexible customized professional reports.

DayCor® Rom
Rom is the most sensitive airborne corona and arcing detection system in a gyro stabilized gimbaled payload. Rom is
specially designed to provide high resolution video output of remotely inspected objects with high signal to background ratio.
Rom enables safe and high speed flight inspection that streamlines maintenance tasks of long overhead lines. Rom’s
reporting software renders flexible customized professional reports

DayCor® Ranger
Ranger is the corona and arcing detection solution for driven inspection. Ranger is an integration of the most sensitive UV
emission detection system with a precise pan-and-tilt unit and a vehicle mount. Control over the inspection systems is from
inside the vehicle. With Ranger inspections of long lines, comfortably, is facilitated. Ranger provides high resolution video
output of remotely inspected objects with high signal to background ratio. Ranger streamlines maintenance tasks of long
overhead lines. Ranger’s reporting software renders flexible customized professional reports

DayCor® Rail
Rail is the most reliable and sensitive corona and arcing detection system designed for railways special needs. Rail is a
ruggedized system, equipped with shock observers, and capable of high speed automatic detection of corona and arcing.
Rail provides high resolution video output of remotely inspected objects with high signal to background ratio. Rail’s reporting
software renders automatic straightforward reports.
OTHER PRODUCTS

SAGO METER ////


PRODUCT
////
CATEGORY
G
SECTION
PAGE 135

The Sagometer™ is a second-generation design of a new technology


developed for the express purpose of accurately monitoring conductor
ground clearance/sag on overhead transmission lines.

The Sagometer™ provides the information needed to confidently:


Š Study conductor behaviour for the purpose of validating and/or enhancing
static rating
Š Establish the dynamic rating for a monitored line
Š Collect data on high-temperature conductor operation
FAULT INDICATORS
OTHER PRODUCTS

////
PRODUCT
////
CATEGORY
G
SECTION
PAGE 136

Merlin Gerin – Fault Indicators.


The Flite 11X range are single phase Fault Passage Indicators for Overhead
Lines. They are used in a group of 3 units at each location in order to allow for
the detection of all possible fault configurations. It must be installed at well-
defined strategic locations along the overhead line such as the start of a spur,
Load Break switch location or at the radial arms of a junction. They mount
directly on the live HV conductor through a specially designed spring operated
clamp. They can be fitted live line via a hot stick fitted with a special adapter.

When a fault occurs all the Flite 11X located between the sub station and the
faulted section will trip and start flashing whilst the Flite 11Xs located beyond
the faulted section will stay idle.

Flashers The red LED flash is very powerful and is seen on a 3600 solid angle of vision.

The Flite 11X Range of Products:


FLITE 110-SA can be adjusted on site with its embedded DIP switches.
The light power of the Flite 110-SA is 40 lumen.

Flite 116-SA has a similar design to the Flite 110-SA but incorporates a
Short Range Radio to allow it to communicate with a G200 RTU and can
be interfaced into SCADA applications via GSM and CDMA telephone
networks using DNP3 protocol.
FAULT INDICATORS
OTHER PRODUCTS

////
PRODUCT
////
CATEGORY
G
SECTION
PAGE 137

Flite 110-SA
Fault passage indicator for overhead networks

Application
A Fault Passage Indicator (FPI) is mandatory to locate faults on Distribution networks. It
must match electrical network characteristics and be very visible in order to help
maintenance crew to quickly locate network faults.
A FPI must be coordinated with the upstream recloser or circuit breaker and therefore,
depending on its location on the MV network, the trigger value may change.
■ If need be, Flite 110-SA is adjustable on site thanks to its embedded
dip-switches.
■ One single product therefore covers all customer requirements.
A FPI is always able to indicate permanent faults, but utilities are often interested to track
transient faults as well (a fault is transient when the upstream protection device eliminates
the fault and successfully recloses).
■ Flite 110-SA offers both facilities with the same unit, flashing differently
upon permanent faults and transient faults but with the same flash power.
■ This feature is user adjustable: one single product therefore covers
these two applications.

Fault detection
Flite 110-SA is fitted with two sensors, one measuring the magnetic field (image of
the current) and one measuring the electric field (image of the voltage). A fault is
either a passing over an absolute current threshold (Imax) or a current variation
FAULT INDICATORS
OTHER PRODUCTS

////
PRODUCT
////
CATEGORY
G
SECTION
PAGE 138

Flite 110-SA Operation

• Detects both short-circuits and Upon installation on a live conductor, Flite 110-SA adjusts itself to power
frequency and network voltage, then enables its fault detection function.
low current earth faults
Fault types: Flite 110-SA detects and indicates both earth faults and short-
• Self adaptation to network circuits between phases. In addition Flite 110-SA indicates both permanent
voltage and frequency and transient faults.

• Highly visible red flash light Fault confirmation: to avoid false indications, faults are confirmed with a
• Indicates both permanent and voltage dip occurring within 70 s after the threshold has been reached, which
indicates that the upstream protection system has opened the circuit or started
transient faults a reclosing cycle.
• User adjustable Inrush restraint: upon line energising, an inrush restraint filter avoids possible
• Very low power consumption false fault indication due to transformer magnetising currents.

Reset: once a permanent fault has been detected and flashing has started,
upon power return, Flite 110-SA waits for the MV to stabilise before resetting
its flash, thus avoiding to stop flashing if the fault has not been cleared.

Transient fault evolution: once Flite 110-SA is busy flashing for a transient
fault, if a permanent fault occurs, the flash fault indication automatically
changes from transient to permanent, thus helping the maintenance crew to
treat fault priorities (first permanent faults, then transient ones).
OTHER PRODUCTS

FAULT INDICATORS ////


////
CATEGORY

PRODUCT
G
SECTION
PAGE 139

Easergy Flite 116-SA and Easergy G200 Terminal Unit


Remote Fault Indicators for overhead lines

Application: fast location of faulted circuits


Traditional Fault Passage Indicators (FPIs or FCIs) with visual indication are of
limited use on distribution networks with long outgoing feeders.
To know the status of FPIs, the utility has to perform a "line patrol" as soon as the
feeder protection device (CB or recloser) trips. This patrol is time-consuming and
some network sections may be hard to access: traffic jams in urban areas, difficult
terrain in rural areas, long outgoing feeders.
The solution is to use the remote indicating Flite116-SA. Payback is quick because
the outage time decreases: gain in non distributed energy is substantial and quality
of supply increases.
Flite 116 communicates through a low power licence free radio with a G200 RTU
able to collect and transmit the information to a feeder automation SCADA or utility
SCADA using open protocols such as IEC or DNP3.
FAULT INDICATORS
OTHER PRODUCTS

////
PRODUCT
////
CATEGORY
G
SECTION
PAGE 140

Easergy Flite 116-SA and Easergy G200 Terminal Unit


Application: fast location of faulted circuits
The Flite 116-SA being a low power consumption unit, the G200 is used as a gateway to link the Flite
116-SA FPI's to any SCADA or W500 intranet maintenance software.
The G200 unit is mounted on an overhead line pole close to the Flite 116 radio Fault Passage Indicator
and communicates:
■ On one side to the Flite 116 units, via a spread spectrum license free radio (915 - 928 MHz) with
low power consumption.
■ On the other side to the distant acquisition system through a long range communication media:
•mobile telephone network (GSM/GPRS/CDMA)
•fixed telephone network (PSTN)
•radio (analog radio or radio modem)
•others through the local RS232 port.

Basic functions
The G200 basic functions are:
■ Date and time stamp all events from Flite 116-SA
■ DNP3 Protocol conversion for transmission to the SCADA system
■ Send all the requested events to the W500 maintenance software and/or to the SCADA
■ Allow remote parametering of Flite 116 units
■ Allow local parametering of Flite 116 and G200 through the RS232 local port
■ Storage capacity: 100 stamped events
■ Monitoring in real time : MV presence/absance, load current
FAULT INDICATORS
OTHER PRODUCTS

////
PRODUCT
////
CATEGORY
G
SECTION
PAGE 141

Easergy Flite 116-SA and Easergy G200 Terminal Unit

Fault detection

Flite 116-SA is fitted with two sensors, one measuring the magnetic field (image
of the current) and one measuring the electric field (image of the voltage).

Upon installation on a live conductor, Flite 11X-SA adjusts itself to power


frequency and network voltage, then enables its fault detection function.

Fault types: Flite 116-SA detects and indicates earth faults (on dI/dt scheme)
and short-circuits with IMAX.

Inrush restraint: upon line energizing, an inrush restraint filter avoids possible
false fault indication due to transformer magnetising currents.

Reset: by timer or by power return.

Power Supply

The G200 is powered by a 10W Solar Panel with a backup battery with a life up
to 5 years.

The Flite 116-SA is powered by a Lithium battery with a life of over 10 years and
G200 unit with solar panel a total flash duration of >400Hours.
OTHER PRODUCTS

CAT-1 ////
PRODUCT
////
CATEGORY
G
SECTION
PAGE 142

CAT-1 TRANSMISSION LINE RATING SYSTEM*


•Increases transmission capability with maximum reliability
•No statistical risk-taking due to weather variability
•Eliminates clearance uncertainty caused by creep

The CAT-1 system monitors the status of transmission lines by measuring the
same parameters used to design the line. It measures the one parameter that is
truly representative of the average condition of the conductor over an entire
transmission line suspension section of several spans—the tension.

The Rating Principle


Figure below represents a simplified example of a multispan transmission line
suspension section. Because the suspension insulator strings at the
suspension towers are free to swing longitudinally, the horizontal component H
of the tension equalizes over the entire suspension section. Normally, the span
shapes can be approximated as parabolas. Therefore, sags S1, S2 and S3 are
all inversely proportional to the horizontal load H and directly proportional to the
squares of the spans lengths L1, L2 and L3, regardless of conductor creep. By
monitoring the conductor tension to verify that it remains above the minimum
design limit, the design clearances at all points of the suspension section can
be maintained.

CAT-1 OPERATING PHILOSOPHY


The CAT-1 operating philosophy is based on recognising that weather variables
are interrelated and probabilistic. The chances of both high temperature and
Transmission line suspension section. low wind speed occurring along an entire suspension section are essentially
Horizontal tension remains constant over the entire suspension section zero. Thus, presently used ampacity limits can be increased by 15-25%.
(ruling span principle) Although this causes a low finite risk, (typically less than 1%) of exceeding the
limiting clearances, applying CAT-1 system will provide a reliable and accurate
warning system for these potential clearance violations.
POLLY-MAR SHROUD
OTHER PRODUCTS

////
PRODUCT
////
CATEGORY
G
SECTION
PAGE 143

Removal by helicopter, of the shroud from


Damage caused by birds composite insulators prior to energising
Shed Catalogue Colour
Diameter Length Number Code
mm mm

93 2850 POLLY-MAR7 Red

114 2650 POLLY-MAR9 Black

114 1370 POLLY-MAR3 Black

122 2700 POLLY-MAR12 Green

149 2730 POLLY-MAR8 Yellow

171 1300 POLLY-MAR2 Purple

178 2750 POLLY-MAR10 Blue


EMERGENCY TOWER
OTHER PRODUCTS

////
////
CATEGORY

PRODUCT
G
SECTION
PAGE 144

Emergency Tower

Assembled 412 x 412 Tower Model

With Accessories
With the ground plate, the cone and a part section of the 412mm x 412mm
(16”x16”) 3m long module, an anchor plate bolted in and the gin pole, on
ball bearings which makes it very easy to manoeuvre.

The sliding gin pole allows you to install tower modules to any height
without obstruction.

Emergency Restoration Towers


Transmission line maintenance.

Bypass construction.

Quick Power Restoration.

From distribution to U.H.V. transmission line.

I.S.O. certified.
AIR BREAK SWITCH
OTHER PRODUCTS

////
////
CATEGORY

PRODUCT
G
SECTION
PAGE 145

Standard Features
•Current carrying parts are manufactured from
HD.HC. Copper.
•Silver plated contacts for high performance, low
maintenance and long life.
•Terminal palms are bright tin plated for use with
copper and aluminium connectors.
•Hinge end contact blade so that current path is not
through pivot joint.
•Flicker arcing horns
•Adjustable phase centres

General purpose air break switch


Options
Rated Voltage 12/24kV to 36kV
•Mounting : Pole top , mid pole and vertical Rated Current 800A to 1000A
•Load break interrupters BIL Rating 150kVp to 200kVp

•Insulators: Porcelain or Polymeric


•Poles Timber, metal or Concrete
•Crossarms: Aluminium, Steel or Insulated

Consult Dulhunty Power for your requirements


G
OTHER PRODUCTS ////
AUTOMATICS CATEGORY

AUTOMATIC DEADENDS AND STRAND - VISE ////


PRODUCT
SECTION
PAGE 146

Steel deadend and stay wire deadend

Universal Grade Strand-vise Dead Ends

Catalogue Diameter No. In Type Range


Number mm inch Standard pack mm

A
R5199 4.31 .1697 50 A 3.56 ~ 5.79
R5255 4.80 .1890 25 E
D

R5200 5.93 .2335 50 A 5.46 ~ 6.85


R5256 6.00 .2362 25 E

R5201 25 A 6.85 ~ 8.00

R5202 8.25 .3248 25 A 8.26 ~ 9.96 E


R5258 9.75 .3839 25 E

R616-SRI 9.525 .375 25 9.525

R5203 10.00 .3937 25 A 9.96 ~ 11.56


R5253.6 11.25 .4429 25 D

R5204 12.00 .4724 25 A 11.56 ~ 13.21

Consult Dulhunty Power for any fitting that may lie outside these ranges
G
OTHER PRODUCTS ////
AUTOMATICS CATEGORY

AUTOMATIC SPLICES ////


PRODUCT
SECTION
PAGE 147

Conductor Splice
ACSR & AAAC Conduct-R-link Splice

Catalogue Conductor Diameter No. In Range


Number stranding mm inch Standard mm
ACSR pack
R7652 6/1/2.50 7.50 .2953 50 5.92 ~ 8.64
R7654 6/1/3.75 11.25 .4429 25 10.52 ~ 12.07

R7656AP 6/4.75+7/1.60 14.30 .5630 20 13.26 ~ 14.86

R7658AP 30/7/2.50 17.50 .6890 10 16.76 ~ 18.72

R7659AP 30/7/3.00 21.00 .8268 10 18.80 ~ 21.72

Consult Dulhunty Power for any fitting that may lie outside these ranges
G
OTHER PRODUCTS ////
AUTOMATICS CATEGORY

AUTOMATIC SPLICES ////


PRODUCT
SECTION
PAGE 148

Universal Grade Strand-link Splice

Catalogue Conductor Diameter No. In Range


Number stranding mm inch Standard mm
SC/GZ [Imp.] pack
R5039 3/2.00 4.31 .1697 50 3.56 ~ 5.79
7/1.60 [7/17] 4.80 .1890

R5040 3/2.75 [3/12] 5.93 .2335 50 5.46 ~ 6.85


7/2.00 6.00 .2362

R5042 7/2.75 [7/12] 8.25 .3248 25 8.25 ~ 9.96


7/3.25 [7/10] 9.75 .3839

R5043 19/2.00 [19/14] 10.00 .3937 25 9.96 ~ 11.56


7/3.75 11.25 .4429

R5044 7/4.00 [7/8] 12.00 .4724 25 11.56 ~ 13.21

Consult Dulhunty Power for any fitting that may lie outside these ranges
G
OTHER PRODUCTS ////
AUTOMATICS CATEGORY

AUTOMATIC DEADENDS ////


PRODUCT
SECTION
PAGE 149

Copper conductor deadend

Conduct-R-vise Dead Ends SDS

Catalogue Conductor Diameter No. In Range


Number stranding mm inch Standard mm
HDCC pack
R41FDS 7/1.75 5.35 .2067 50 4.67 ~ 5.33
R41SDS 7/.064 4.88 .1920 50
R47SDS 7/2.00 6.00 .2362 25 5.72 ~ 6.73
7/.080 6.10 .2400 25
R101SDS 7/2.75 8.25 .3248 25 7.75 ~ 8.64
7/.104 7.93 .3120 FDS
19/1.75 7.75 .3445
19/.064 8.13 .3200
R107SDS 7/3.00 9.00 .3543 25 8.64 ~ 9.78
7/.118 8.99 .3540
R207SDS 19/2.00 10.00 .3937 10 10.00 ~ 10.67
19/.083 10.54 .4150

Consult Dulhunty Power for any fitting that may lie outside these ranges
G
OTHER PRODUCTS ////
AUTOMATICS CATEGORY

AUTOMATIC SPLICES ////


PRODUCT
SECTION
PAGE 150

Copper conductor splice


Conduct-R-link Splice
Catalogue Conductor Diameter No. In Range
Number stranding mm inch Standard mm
HDCC pack
R61 7/.048 3.66 .1440 100 3.71 ~ 4.27
R41 7/1.75 5.35 .2067 50 4.67 ~ 5.33
7/.064 4.88 .1920
R47 7/2.00 6.00 .2362 50 5.72 ~ 6.73
7/.080 6.10 .2400
R27 7/.093 7.09 .2790 50 6.86 ~ 7.75

R101 7/2.75 8.25 .3248 25 7.75 ~ 8.64


7/.104 7.93 .3120
19/1.75 7.75 .3445
19/.064 8.13 .3200
R107 7/3.00 9.00 .3543 25 8.64 ~ 9.78
7/.118 8.99 .3540
R207 19/2.00 10.00 .3937 10 10.00 ~ 10.67
19/.083 10.54 .4150
R407 19/2.75 13.75 .5413 25 12.32 ~ 13.72
19/.104 13.21 .5200

Consult Dulhunty Power for any fitting that may lie outside these ranges
G
OTHER PRODUCTS ////
AUTOMATICS CATEGORY

AUTOMATIC SPLICES AND STRAND - VISE ////


PRODUCT
SECTION
PAGE 151

Single wire fittings

Wire-vise Dead Ends


Wire-Link Splices
WireVise

Catalogue Diameter No. In Style


Number Min mm MAX Standard
mm pack
R5057 1.6 2.5 100 Link
R5056V 100 Vise
R5059 2.5 2.9 100 Link
R5058V 500 Vise
R5063 2.8 3.4 100 Link Wire Link
R5062V 300 Vise
R5065 3.5 5.5 200 Link
R5064V 100 Vise
RT-RBK 10 Ratchet
tensioner

Consult Dulhunty Power for any fitting that may lie outside these ranges
RT-RBK
INSULATOR PINS

INDEX ////
////
CATEGORY

PRODUCT
H
SECTION
PAGE 152

INSULTOR PINS.................................................
INSULATOR PINS

INSULATOR PINS ////


PRODUCT
////
CATEGORY
H
SECTION
PAGE 153

Design Reference: AS 1154

Material: Galvanized Steel


Lead or Plastic heads available

SWANECK

Cantilever Shank Minimum Stem Head


Minimum collar length pattern
failing Diameter Length Thread length diameter mm
Pin type load mm mm Minimum mm
kN mm
AS1154 C D E
A B
B/100/3.5 3.5 16 140 50 40 100 B

A/130/7 7 20 165 80 50 130 A

C/150/7 7 20 165 80 60 150 C

C/150/11 11 24 165 80 60 150 C

C/200/11 11 24 165 80 65 200 C

C/300/7 7 24 165 80 75 300 C

SWANECK 3.5 12 125 75 35 100 B


INSULATORS

INDEX ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 154

AS INSULATOR………………………………………….Page 156 - 171


IEC INSULATOR…………………………………………Page 172 - 179
ANSI INSULATOR……..……………………………......Page 180
COMPSITE INSULATOR…………………………….....Page 181 - 188
AUSTRALIAN STANDARD INSULATOR

INDEX ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 155

AS INSULATOR INDEX
PORCELAIN INSULATOR:
Ball & Socket Disc Insulator: Standard Profile……………….. Page 156
Tongue & Clevis Disc Insulator: Standard Profile…………… Page 157
Ball & Socket Disc Insulator: Fog Profile…... ………………… Page 158
Ball & Socket Disc Insulator: Desert Fog Profile…………….. Page 159
Tie Top Line Post Insulator ………………………………………. Page 160
Clamp Top Horizontal Line Post Insulator……………………… Page 161
Clamp Top Vertical Line Post Insulator…………………………. Page 162
Pin Type Standard Profile Insulator……………………………… Page 163
Pin Type Aerodynamic Profile Insulator ……………………….. Page 164
Pin Type Fog Profile Insulator……………………………………. Page 165
Spool and Shackle Type Insulator……………………………….. Page 166
Strain Type Insulator………………………………………………. Page 167

GLASS INSULATOR:
Ball & Socket Disc Insulator: Standard profile………………. Page 168
Ball & Socket Disc Insulator: Fog profile……………………... Page 169
Tongue & Clevis Insulator: Standard Profile ………………… Page 170

POST INSULATOR:
QLD Station Post …………………………………………………….Page 171
INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 156

AS PORCELAIN INSULATOR Ball & Socket


STANDARD PROFILE TYPE

Power Frequency
Catalogue Diameter Spacing Creepage Coupling Min. Min. Min. Withstand Volt. kV Approx.
Number D H distance Size Mechanical Routine Lightning Net
mm mm mm Failing Test Impulse Weight
Min. Min.
Load Load Withstand kg
Wet One Puncture
kN kN Volt. kV
Minute Volt.

UP70BLZ 255 146 292 16 70 28 110 40 110 4.6

UP80BL 255 146 292 16 80 32 110 40 110 4.6

UP120BS 255 146 292 16 120 48 110 40 110 6.0

UP160BL 280 146 305 20 160 64 110 45 115 7.5


INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 157

AS PORCELAIN INSULATOR
TONGUE & CLEVIS TYPE

Power Frequency
Catalogue Diameter Spacing Creepage Coupling Min. Min. Min. Withstand Volt. kV Approx.
Number D H distance Size Mechanical Routine Lightning Net
Min. Min.
mm mm mm Failing Test Impulse Weight
Wet Puncture
Load Load Withstand kg
One Volt.
kN N. cm Volt. kV Minute
UP70C 255 146 292 16C 70 28 110 40 110 4.6
UP70CP-HEX 255 146 360 16 HEX 70 28 110 40 110 6
INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 158

AS PORCELAIN INSULATOR Ball & Socket


FOG PROFILE TYPE

Power Frequency
Catalogue Diameter Spacing Creepage Coupling Min. Min. Min. Withstand Volt. kV Approx.
Number D H distance Size Mechanical Routine Lightning Net
mm mm mm Failing Test Impulse Min. Min. Weight
Load Load Withstand Wet One Puncture kg
kN kN Volt. kV Minute Volt.

UP70BLP 255 146 432 16 70 28 120 42 120 7.0

UP80BLP 255 146 432 16 80 32 120 42 120 7.0

UP120BLP 255 146 432 16 120 48 120 42 120 8.0

UP160BSP 300 160 440 20 160 64 135 42 120 10.2


////
CATEGORY

//// SECTION
PRODUCT

AS PORCELAIN INSULATOR Ball & Socket


DESERT FOG TYPE

Type (IEC Class) XWP-70 XWP-100 XWP-160

Creepage distance, mm 400 400 450

Disc diameter, D mm 254 254 300

Unit spacing, H mm 146 146 155

Power Frequency Dry, kV 90 90 90


flashover voltage
Wet, kV 45 45 50

Power Frequency Dry., kV 80 80 80


withstand voltage
Wet., kV 40 40 45

Standard coupling to IEC 120 16B 16B 20

M & E Combined stength, kN 70 100 160

Net weight, kg 5.5 6.5 7.5

Quantity per case 5 5 5


INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 160

AS PORCELAIN INSULATOR
TIE TOP LINE POST TYPE

Type (AS Class) R11ET150N-310 R11ET145N R11ET325N R11ET325L R18ET150N

Height & Diameter, stud, mm 310 x 165 x M24 487 x 146 x M24 536 x 200 x M24 790 x 184 x M24 285 x 166 x M20

Creepage distance, mm 565 610 1250 1800 425

Protected Creepage distance, mm 220 100 530 530

Power Frequency wet with, kV 50 50 140 140 38

Impulse withstand, kV 150 150 350 350 150

Cantilever strength, kN 11 11 11 11 18

Net weight, kg 7.5 13.3 24.8 25 11


INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 161

AS PORCELAIN INSULATOR
CLAMP TOP HORIZONTAL LINE POST TYPE
Type (AS Class) R11EH150N-1 R11EH150N R11EH325N R11EH350N

Height & Diameter, stud, mm 540 x 146 x M24 805 x 170 x M24 845 x 184 x M24

Creepage distance, mm 565 610 1250 1800

Protected Creepage distance, mm 220 100 530 530

Power Frequency wet withstand, kV 50 50 140 140

Impulse withstand, kV 150 150 325 350

Cantilever strength, kN 11 11 11 11

Net weight, kg 8.7 14.5 26 –


INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 162

AS PORCELAIN INSULATOR
CLAMP TOP VERTICAL LINE POST TYPE
Type (AS Class) R11EC150N-1 R11EC150N R11EC325N R11EC350N

Height & Diameter, stud, mm 775 x 170 x M24

Creepage distance, mm 565 610 1250 1800

Protected Creepage distance, mm 220 100 530 530


Power Frequency wet withstand, kV 50 50 140 170

Impulse withstand, kV 150 150 325 350

Cantilever strength, kN 11 11 11 11

Net weight, kg 8.7 15.5 26 –


INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 163

AS PORCELAIN INSULATOR
STANDARD PROFILE PIN TYPE

Type (AS Class) SLP/11/180 SLP/22/420 SLP/33/534 LP.LV

Height & Diameter, Neck mm 110 X 150 X 76 168 X 229 X 113 190 X 257 X 113 91 X 82

Creepage distance, mm 180 420 534 –

Power Frequency wet withstand, kV 32 60 65 –

Impulse withstand, kV 95 150 170 –

Cantilever strength, kN 7 11 11 7

Net weight, kg 1.8 5.3 6.3 0.8

Insulator pin A/130/7 C/150/11 C/200/11 B/100/3.5

Quantity per case 16 6 4 30

SLP Type LP.LV Type


INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 164

AS PORCELAIN INSULATOR
AERODYNAMIC PROFILE, C PIN TYPE
Type (AS Class) ALP/11/275 ALP/22/450 ALP/22/490 ALP22/520 ALP33/710 ALP/33/920

Height and Diameter, 160 X 150 200 X 160 250 X 165 210 X 200 265 X 220 320 X 240
Neck, mm (Radio Free) X 76 X 76RF X 76 X 76 X 76 X 76RF
Creepage distance, mm 275 450 490 520 710 920
P.F. wet withstand, kV 32 50 50 50 70 90
Impulse withstand, kV 95 150 160 150 200 220
Cantilever strength, kN 7 11 11 11 7 11
Net weight, kg 1.8 3.5 4.2 5 8 14.3
Insulator pin C/150/7 C/200/11 C/200/11 C/200/11 C/300/7 C/300/7
Quantity per case 12 6 6 2 2 2
INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 165

AS PORCELAIN INSULATOR FOG PIN TYPE

Type (AS Class) FLP/11/360 FLP/22/480 11-22 Bridging

Height & Diameter, Neck mm 160 X 152 X 76 A 200 X 250 X 76 C 210 X 140 X ø20
Creepage distance, mm 360 480 355
Power Frequency wet withstand, kV 28 50 50
Impulse withstand, kV 95 145 125
Cantilever strength, kN 7 11 5
Net weight, kg 2 6.7
Insulator pin A/130/7 C/150/11 C/200/11
Quantity per case 4

0.5mm radius chamfer 140


114

20

Hole size 20

100

210

Pattern “C” Zinc thread


insert to AS1154.2 46

140
INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 166

AS PORCELAIN INSULATOR
SPOOL AND SHACKLE TYPE INSULATOR

Type (AS Class) SH. LV. 1 SH.LV. 2 SH11


Height & Diameter, mm 54 x 57 76 x 80

Creepage distance, mm – – 180

Power Frequency wet withstand, kV – – 30

Impulse withstand, kV – – 95

Transverse strength, kN 9 20 22

Net weight, kg 0.2 0.6 –


Quantity per case 120 24 –

SH.LV Type
SH 11
INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 167

AS PORCELAIN INSULATOR
STRAIN INSULATOR

TYPE (AS Class) GY 2 GY 3 GY 4 V6/43


H 146 216 280 202
h 73 89 89 152
Dimension,
h1 99 133 165 177
mm D 73 115 115 36
d 44 67 67 36
d1 22 38 38 6
Power Frequency wet withstand, kV 15 20 30 15
Mechanical failing load, kN 71 222 222 4.45
Net weight 1.1 4.3 5.7 1
Quantity per case 20 8 6 20
INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 168

AS GLASS INSULATOR Ball & Socket


STANDARD TYPE

Power Frequency
Catalogue Diameter Spacing Creepage Coupling Min. Min. Min. Withstand Volt. kV Approx.
Number D H distance Size Mechanical Impact Lightning Net
mm mm mm Failing Failing Impulse Min. Min. Weight
Load Load Withstand Wet One Puncture kg
kN N. cm Volt. kV Minute Volt.

UG45BL 175 110 190 11 45 450 75 33 110 1.8

UG70BLZ 255 146 320 16 70 565 100 40 110 3.77

UG80BLZ 255 146 320 16 80 565 100 40 110 3.85

UG125BLZ 255 146 360 20 125 355 95 40 120 5.0

UG160BS 280 146 380 20 160 1017 105 42 110 6.1


INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 169

AS GLASS INSULATOR Ball & Socket


FOG TYPE

Power Frequency
Catalogue Diameter Spacing Creepage Coupling Min. Min. Min. Withstand Volt. kV Approx.
Number D H distance Size Mechanical Impact Lightning Net
mm mm mm Failing Failing Impulse Weight
Min. Min.
Load Load Withstand kg
Wet One Puncture
kN N. cm Volt. kV Minute Volt.

UG70BP 255 146 400 16 70 565 120 45 120 4.5

UG120BP 280 146 450 16 120 678 120 45 120 5.5

UG160BP 280 170 450 20 160 1017 130 50 120 7.0

UG210BP 320 170 540 20 210 1017 130 50 120 9.2


INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 170

AS GLASS INSULATOR Tongue & Clevis TYPE

Power Frequency
Catalogue Diameter Spacing Creepage Coupling Min. Min. Min. Withstand Volt. kV Approx.
Number D H distance Size Mechanical Impact Lightning Net
Min. Min.
mm mm mm Failing Failing Impulse Weight
Wet Puncture
Load Load Withstand kg
One Volt.
kN N. cm Volt. kV Minute

UG70C 255 146 320 16C 70 565 100 40 110 4.0


INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 171

QLD STATION POST INSULATOR

Type (IEC Class) C8-95-II-254 C6-200-II-380


Height & Diameter, mm 254 x 168 380 x 168
PCD, mm 76 76
Creepage distance, mm 360 760
Withstand P.F. wet, kV 38 70
voltage
Impulse, kV 95 200
Cantilever strength, kN 8 6
Torsion strength, N-m 1200 1000
Net weight, kg 10 14
INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 172

IEC INSULATOR INDEX


PORCELAIN INSULATOR:
Solid-Core Station Post Insulator 6kN……….. Page 173
Solid-Core Station Post Insulator 4kN……….. Page 174
Solid-Core Station Post Insulator Multi……… Page 175
Ball & Socket Disc Insulator ………………….. Page 176
Tongue & Clevis Disc Insulator……………….. Page 177

GLASS INSULATOR:
Tongue & Clevis Disc Insulator………………...Page 178
Ball & Socket Disc Insulator ……………………Page 179
INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 173

IEC 273 STATION POST INSULATOR

Type (IEC Class) C6-95-II C6-125-II C6-150-II C6-170-II C6-200-II C6-250-II C6-325-II
Height & Diameter, mm 255 x 160 305 x 160 355 x 168 445 x 168 475 x 168 560 x 190 770 x 190
PCD, mm 76 76 76 76 76 127 127
Creepage distance, mm 380 500 660 850 950 1200 1600
Withstand P.F. wet, Kv 38 50 50 70 70 95 140
voltage
Impulse, Kv 95 125 150 170 200 250 325
Cantilever strength, kN 6 6 6 6 6 6 6
Torsion strength, N-m 800 800 1200 1500 1800 2000 2500
Net weight, kg 8 9 11 12 14 18 32
INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 174

IEC 273 STATION POST INSULATOR

Type (IEC Class) C4-95-II C4-125-II C4-150-II C4-170-II C4-200-II C4-250-II C4-325-II
Height & Diameter, mm 255 x 160 305 x 160 355 x 168 445 x 168 475 x 168 560 x 190 770 x 190
PCD, mm 76 76 76 76 76 127 127
Creepage distance, mm 380 500 660 850 950 1200 1600
Withstand P.F. wet, Kv 38 50 50 70 70 95 140
voltage
Impulse, kV 95 125 150 170 200 250 325
Cantilever strength, kN 4 4 4 4 4 4 4
Torsion strength, N-m 800 800 1000 1200 1200 1800 2000
Net weight, kg 8 9 11 12 14 18 32
INSULATOR
INSULATORS

////
PRODUCT
////
CATEGORY
I
SECTION
PAGE 175

IEC 273 STATION POST INSULATOR

Type (IEC Class) C4-550-II C6-550-II C8-550-II C10-550-II C4-1050-II C6-1050-II C8-1050-II
Height & Diameter, mm 1200 x 230 1200 x 230 1200 x 230 1200 x 230 2300 x 250 2300 x 250 2300 x 250
PCD, mm 127 127 127 127 127 127 127
Creepage distance, mm 2900 2900 2900 2900 5650 5650 5650
Withstand P.F. wet, kV 230 230 230 230 460 460 460
voltage
Impulse, kV 550 550 550 550 1050 1050 1050
Cantilever strength, kN 4 6 8 10 4 6 8
Torsion strength, N-m 3000 4000 4000 4000 3000 3000 4000
Net weight, kg 48 56 62 70 125 130 165

C-550-II Type C-1050-II Type


INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 176

IEC BALL AND SOCKET

Power Frequency
Catalogue Diameter Spacing Creepage Coupling Min. Min. Min. Withstand Volt. kV Approx. Net
Number D H distance Size Mechanical Routine Lightning Weight
(IEC type) Min. Min.
mm mm mm (IEC 120) Failing Test Impulse kg
Wet One Puncture
Load Load Withstand
Minute Volt.
kN kN Volt. kV

U70BL 255 146 292 16 70 28 100 40 110 4.6

U80BL 255 146 292 16 80 32 100 40 110 4.6

U100BL 255 146 292 16 100 40 100 40 110 5.5

U120BS 255 146 292 16 120 48 110 40 110 6.0

U210BS 280 170 335 20 210 84 105 45 120 9.0

U300B 320 195 375 24 300 120 110 47 130 13.5

U160BS 280 146 305 20 160 64 105 45 115 7.5

U70BP 255 146 432 16 70 28 120 45 115 6.5

U80BP 255 146 432 16 80 32 115 45 115 6.5

U100BP 255 146 432 16 100 40 115 45 115 7.5

U120BP 255 146 432 16 120 48 115 45 115 7.8


INSULATORS

INSULATOR ////
PRODUCT
////
CATEGORY
I
SECTION
PAGE 177

IEC TONGUE AND CLEVIS

Power Frequency
Catalogue Diameter Spacing Creepage Coupling Min. Min. Min. Withstand Volt. kV Approx.
Number D H distance Size Mechanical Routine Lightning Net
Min. Min.
(IEC type) mm mm mm (IEC 120) Failing Test Impulse Weight
Wet Puncture
Load Load Withstand kg
One Volt.
kN kN Volt. kV Minute
U70C 255 146 292 16C 70 28 110 40 110 4.6
U80C 255 146 292 16C 80 32 110 40 110 4.6
U70BP 255 146 432 16C 70 28 115 45 120 6.8
U80BP 255 146 432 16C 80 32 115 45 120 6.8
INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 178

IEC TOUGHENED GLASS INSULATOR


Tongue & Clevis

Power Frequency
Catalogue Diameter Spacing Creepage Coupling Min. Min. Min. Withstand Volt. kV Approx.
Number D H distance Size Mechanical Impact Lightning Net
Min. Min.
mm mm mm Failing Failing Impulse Weight
Wet Puncture
Load Load Withstand kg
One Volt.
kN N. cm Volt. kV Minute

DG-U70C 255 146 320 16C 70 565 100 40 110 4.0


INSULATOR
INSULATORS

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 179

IEC TOUGHENED GLASS INSULATOR


Ball & Socket STANDARD PROFILE

Power Frequency
Catalogue Diameter Spacing Creepage Coupling Min. Min. Min. Withstand Volt. kV Approx.
Number D H distance Size Mechanical Impact Lightning Net
mm Min. Min. Weight
mm mm Failing Failing Impulse
Wet Puncture kg
Load Load Withstand
One Volt.
kN N. cm Volt. kV
Minute

DG-U70BS 255 127 320 16 70 565 100 40 110 3.7

DG-U70B 255 140 320 16 70 565 100 40 110 3.7

DG-U70BL 255 146 320 16 70 565 100 40 110 3.7

DG-U80BL 255 146 320 16 80 565 100 40 110 3.8

DG-U100BL 255 146 320 16 100 678 100 40 110 4.1

DG-U120BL 255 146 320 16 120 678 100 40 110 4.2

DG-U210BS 280 170 390 20 210 1017 105 42 120 6.7

DG-U300B 320 195 485 24 300 1017 110 45 120 10.7

DG-U160BS 280 146 380 20 160 1017 105 42 110 6.1

DG-U160BL 280 170 380 20 160 1017 105 42 110 6.2

DG-U70BP1 255 146 400 16 70 565 120 45 120 4.5

DG-U100BP 280 146 450 16 100 678 120 45 120 5.4

DG-U120BP 280 146 450 16 120 678 120 45 120 5.5

DG-U160BP 280 170 450 20 160 1017 130 50 120 7.0

DG-U210BP 320 170 540 20 210 1017 130 50 120 9.2


INSULATORS

INSULATOR ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 180

ANSI INSULATOR

Please refer to the ANSI Insulator Catalogue

For further information please call Dulhunty Power Ltd

Tel: +61 2 9870 7277


COMPOSITZ INSULATOR

INDEX ////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 181

Distribution DS –M Series 15kV – 28kV………. Page 182


Long Rod Suspension / Tension: 1…………… Page 183
Long Rod Suspension / Tension: 2…………… Page 184
Line Post Insulator………………………………. Page 185
Line Post Base Insulators……………………… Page 186
Line Post End Fittings : 1……………………… Page 187
Line Post End Fittings : 2……………………… Page 188
COMPOSITZ INSULATOR

DS-M SERIES ////


////
CATEGORY

PRODUCT
I
SECTION
PAGE 182

RELIABLE COMPOSITZ INSULATORS


DISTRIBUTION DS – M

DS-M Series
15kV – 28kV

Typical Catalogue Section Dry Arc Leakage Electrical Flashover (kV) Weight
Line No. Length
Voltage 60 Hz CIFO
kV mm mm mm Dry Wet Pos Neg Kg.
15 DS-15M 330 192 401 90 65 140 145 1.18
28 DS-28M 432 294 628 130 100 190 220 1.32

Available only in Australia, New Zealand and the South Pacific


COMPOSITZ INSULATOR

COMPOSITZ INSULATOR ////


////
CATEGORY

PRODUCT
I
SECTION
PAGE 183

RELIABLE COMPOSITZ INSULATORS


LONG ROD SUSPENSION / TENSION

S 2 9 8 0 6 8 B X 0
TOWER LINE
ELECTRICAL AND DIMENSIONAL ORDERING
INSULATOR END FITTING SECTION LENGTH LEAKAGE CORONA RPP EXAMPLE
TYPE TYPE (INCHES) LEVEL RINGS INTERNAL
To order a 68” insulator with eye/ball end fittings,
(SPECIFIED USE
MECHANICAL heavy contamination leakage, 50,000 SML rating the
LOAD) Catalogue Number would be S298068BX00

Tower Line
Type Size SML RTL Light Contamination – A A – none 8”
4 -Y Clevis
mm kN kN Heavy Contamination – B B- none 12”
S0 16 70 35
5 -Tongue
Variable Leakage - V C- none 17”
S1 16 120 60 6 -Clevis
S2 20 220 110 7 -Socket D -8” 8”
S4 24 330 115 E- 12” 12”
S5 16 133 66.5
8 -Ball
S6 18 160 80 9 -Eye F- 17” 17”
G –8” 12”
H –12” 17”
V- 12” 17”
X - none none

Available only in Australia, New Zealand and the South Pacific


////
CATEGORY

//// SECTION
PRODUCT

RELIABLE COMPOSITZ INSULATORS


LONG ROD SUSPENSION / TENSION

SUSPENSION INSULATORS
STRENGTH AND CLASSIFICATION OF AVAILABLE END FITTINGS BY ROD SIZE

END FITTING TYPE

INSULATOR ANSI IEC ANSI IEC ANSI IEC ANSI IEC ANSI IEC ANSI IEC

S1 25klb *Yes 52-6 52-6 52-6 52-6 *Yes


120kN *Yes 16-C 16 16
S5 30klb *Yes 52-6 52-6 52-5 52-5 *Yes
S6+ 36 klb 24 24
160kN 20 20 *Yes
S2 50 lkb *Yes 52-10(1) 52-10 52-11 52-11 *Yes
210 kN 19-C 20 20
30 klb 52-5 52-5
S4 80 klb *Yes (1) *Yes

Available only in Australia, New Zealand and the South Pacific


COMPOSITZ INSULATOR
COMPOSITZ INSULATOR

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 185

RELIABLE COMPOSITZ INSULATORS


LINE POST INSULATORS
H 2 9 1 0 4 0 B X 0

INSULATOR END FITTING NOMINAL SECTION LEAKAGE CORONA RPP


TYPE TYPE LENGTH (INCHES) LEVEL RINGS INTERNAL
USE

Orientatio n B ase Type To wer Line


Line End Fitting
H – Ho rizo ntal 1-2 P iece Flat SF-01 A - no ne 6”
0-2 Ho le To ngue
P o st C-2 P iece Gain SG-01 B - no ne 11”
1-2 Ho le Dro p To ngue
V- Vertical P o st 3 –3” B o lt Circle X - no ne no ne
2- Single Tunnio n
4 - 3” Stud B ase 3-3” B o lt Circle
Ro d Diameter 5-5” B o lt Circle 4-3” B o lt Circle w/ Trunnio n
1-2.0” 6-Swivel B ase 5-5” B o lt Circle
2-2.5” 8-No B ase (ancho r 6-5” B o lt Circle w/ Trunnio n
3-3.0” o nly) 7- F-Neck
9-2 P iece Gain 9-3” B o lt Circle Sho rt w/ Light Co ntaminatio n – A
X- no ne Trunnio n Heavy Co ntaminatio n – B
A -3” B o lt Circle (sho rt) Variable Leakage - V
C- Extended Dro p To ngue
D- Do uble Trunnio n
X- No ne

ELECTRICAL AND DIMENSIONAL ORDERING EXAMPLE


To order a 40" insulator w ith a 2 Piece Gain steel base, 2 hole drop tongue, heavy contamination leakage,
and 2.5" rod diameter, the Catalogue Number w ould be H291040BX00

Available only in Australia, New Zealand and the South Pacific


COMPOSITZ INSULATOR

COMPOSITZ INSULATOR ////


PRODUCT
////
CATEGORY
I
SECTION
PAGE 186

RELIABLE COMPOSITZ INSULATORS


LINE POST BASES

Line Post Base Dimensions

H2/H3 2 PIECE GAIN BASE H2FLAT BASE H2 ANCHOR H1 3’ BOLT CIRCLE AND STUD BASE

H2 SWIVEL BASE SG-01 GAIN BASE SF-01 FLAT BASE H2 5’ BOLT CIRCLE

Available only in Australia, New Zealand and the South Pacific


COMPOSITZ INSULATOR

COMPOSITZ INSULATOR ////


////
CATEGORY

PRODUCT
I
SECTION
PAGE 187

RELIABLE COMPOSITZ INSULATORS


LINE POST END FITTINGS

TRUNNION H2 2 HOLE TONGUE DROP TONGUE

H2 & H3 DOUBLE TRUNNION H2 EXTENDED DROP EYE VERTICAL TRUNNION

Available only in Australia, New Zealand and the South Pacific

Dimensions next page


COMPOSITZ INSULATOR
COMPOSITZ INSULATOR

////
////
CATEGORY

PRODUCT
I
SECTION
PAGE 188

RELIABLE COMPOSITZ INSULATORS


LINE POST END FITTINGS

Line Fitting Ins A B C D E Mat.

Trunnion H1 102 28 19 18 - MCI

Trunnion H2 102 28 25 15 - MCI

Trunnion H3 102 28 25 19 - MCI

Vertical Trunnion V1 102 53 MCI 66 kV Trident 2.5kN

Vertical Trunnion V2 102 76 MCI

Drop Eye H1 13 33 51 19 13 x 38 Al

Drop Eye H2 13 33 51 19 13 x 38 MCI

Drop Eye H3 13 38 51 19 13 x 38 MCI

Refers to previous page (P186) 132kV Horizontal Vee 45kN

Available only in Australia, New Zealand and the South Pacific


HIGH TEMPERATURE CONDUCTORS

HIGH TEMPERATURE ////


////
CATEGORY

PRODUCT
J
SECTION
PAGE 189
HIGH TEMPERATURE CONDUCTORS

HIGH TEMPERATURE ////


////
CATEGORY

PRODUCT
J
SECTION
PAGE 190
HIGH TEMPERATURE CONDUCTORS

HIGH TEMPERATURE ////


////
CATEGORY

PRODUCT
J
SECTION
PAGE 191

Page 191
CONDUCTORS INFORMATION

INDEX ////
////
CATEGORY

PRODUCT
K
SECTION
PAGE 192

AUSTRALIAN STANDARD CONDUCTORS


Cross Sectional Comparison……………………………………….…………………………………... Page 193
Aluminium Conductor (Galvanised) Steel Reinforced……………………………………………... Page 194 -196
Aluminium Conductor (Galvanised) Steel Reinforced Extra High Strength……………………. Page 197
Aluminium Conductor…………………………………………………………………………………..… Page 198
All Aluminium Alloy Conductor…6201…………………………………………………….………….. Page 199
All Aluminium Alloy Conductor…1120…………………………………………………………..….… Page 200
Steel Conductor / Galvanised…………………………………………………………………………… Page 201
Hard Drawn Copper Conductor………………………………………………………………………… Page 202
CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


PRODUCT
////
CATEGORY
K
SECTION
PAGE 193

Nominal. Conductor O.D. Nominal. Conductor O.D.


Cross Sectional Cross Sectional
mm Inch mm Inch
Area Area
mm² mm²

0.5 .80 .031 70 10.70 .421

1.0 1.13 .044 95 12.46 .490


12.60 .496
1.5 1.38 .054
1.50 .059 120 14.21 .559

2.5 2.01 .079 150 15.75 .620

4 2.55 .100 185 17.64 .694

6 3.12 .122 240 20.25 .797

10 4.05 .159 300 22.68 .892

16 5.10 .200 400 25.65 1.009

25 6.42 .252 500 28.80 1.133


6.75 .265
630 32.76 1.289
35 7.65 .301
800 37.05 1.458
50 8.90 .350
1000 41.60 1.637
CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 194

Aluminium Conductor (Galvanised) Steel Reinforced


ACSR/GZ / 1350 Aust. Standard - AS 3607

Strands/ Overall Nominated Nominated


Code Wire Diameter Minimum Mass
Name Diameter (approx) Breaking kg per km
Load
mm mm kN

Almond 6/1/2.50 7.50 10.5 119


Apple 6/1/3.00 9.00 14.9 171
Banana 6/1/3.75 11.25 22.7 268
Cherry 6/4.75+7/1.60 14.30 33.4 402
Grape 30/7/2.50 17.50 63.5 677
Lemon 30/7/3.00 21.00 90.4 973
Lime 30/7/3.50 24.50 122 1320
Mango 54/7/3.00 27.00 119 1440
Orange 54/7/3.25 29.25 137 1690
Olive 54/7/3.50 31.50 159 1960
Pawpaw 54/3.75+19/2.25 33.75 1780 2240

Peach 54/4.75+19/2.85 42.75 284 3600


CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 195

Aluminium Conductor (Aluminised) Steel Reinforced


ACSR/AZ /1350 Aust. Standard - AS 3607

Strands/ Overall Nominated Nominated


Code Wire Diameter Minimum Mass
Name Diameter (approx) Breaking kg per km
Load
mm mm kN

Barley 6/1/2.50 7.50 10.2 118

Bean 6/1/3.00 9.00 14.5 170

Cabbage 6/1/3.75 11.25 21.4 265

Carrot 6/4.75+7/1.60 14.30 32.0 399

Corn 30/7/2.50 17.50 61.6 675

Garlic 30/7/3.00 21.00 87.2 973

Millet 30/7/3.50 24.50 116 1320

Oats 54/7/3.00 27.00 115 1440

Onion 54/7/3.25 29.25 132 1690

Parsnip 54/7/3.50 31.50 153 1960

Potato 54/19/2.25 33.75 177 2250

Rice 54/4.75+19/2.85 42.80 277 3600


CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 196

Aluminium Conductor (Aluminium Clad) Steel Reinforced


ACSR/AC / 1350 Aust. Standard - AS 3607

Strands/ Overall Nominated Nominated


Code Wire Diameter Minimum Mass
Name Diameter (approx) Breaking kg per km
Load
mm mm kN

Angling 6/1/2.50 7.50 10.6 113

Archery 6/1/3.00 9.00 15.1 163

Baseball 6/1/3.75 11.25 22.3 254

Bowls 6/4.75+7/1.60 14.30 32.7 385

Cricket 30/7/2.50 17.50 64.4 636

Darts 30/7/3.00 21.00 91.6 913

Diving 30/7/3.50 24.50 122 1240

Golf 54/7/3.00 27.00 120 1380

Gymnastics 54/7/3.25 29.25 139 1620

Hurdles 54/7/3.50 31.50 159 1880

Lacrosse 54/3.75+19/2.25 33.75 180 2150

Rugby 54/4.75+19/2.85 42.80 287 3450


CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 197

Aluminium Conductor (Galvanised) Steel Reinforced


ACSR/GZ Aust. Standard - AS 3607
Extra High Strength

Strands/ Overall Nominated Nominated


Minimum Mass
Code Wire Diameter
kg per km
Name Diameter (approx) Breaking
Load
mm mm kN

Quince 3/4/1.75 5.25 12.7 95.9


Raisin 3/4/2.50 7.50 24.4 193
Sultana 4/3/3.00 9.00 28.3 242
Walnut 4/3/3.75 11.25 43.9 379
CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 198

Aluminium Conductor
AAC / 1350 Aust. Standard - AS 1531

Strands/ Overall Nominated Nominated


Code Wire Diameter Minimum Mass
Name Diameter (approx) Breaking kg per km
Load
mm mm kN

Leo 7/2.50 7.50 5.71 94.3


Libra 7/3.00 9.00 7.98 135

Mars 7/3.75 11.30 11.8 211

Mercury 7/4.50 13.50 16.9 304

Moon 7/4.75 14.30 18.9 339

Neptune 19/3.25 16.30 24.7 433

Pluto 19/3.75 18.80 31.9 576

Saturn 37/3.00 21.00 42.2 721

Taurus 19/4.75 23.80 51.3 924

Triton 37/3.75 26.30 62.2 1120

Uranus 61/3.25 29.30 75.2 1400

Venus 61/3.75 33.80 97.2 1860

Virgo 91/4.50 49.50 207 4010


CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 199

All Aluminium Alloy Conductor


AAAC 6201 Aust. Standard - AS 1531
Strands/ Overall Nominated Nominated
Code Wire Diameter Minimum Mass
Name Diameter (approx) Breaking kg per km
mm mm Load kN

Diamond 7/2.50 7.50 9.64 94.3


Dolomite 7/2.75 8.25 11.6 113
Emerald 7/3.00 9.00 13.9 135
Garnet 7/3.75 11.25 21.7 211
Jade 7/4.50 13.50 31.2 304
Jasper 7/4.75 14.25 34.8 339
Opal 19/3.25 16.30 44.2 433
Patronite 19/3.50 17.50 51.3 503
Pearl 19/3.75 18.75 58.8 576
Ruby 37/3.00 21.00 73.5 721
Ruthenium 37/3.25 22.75 86.1 845
Rutile 19/4.75 23.75 94.4 924
Sapphire 37/3.75 26.25 115 1120
Spinel 61/3.25 29.25 135 1400
Tantalum 61/3.50 31.50 156 1620
Topaz 61/3.75 33.75 179 1860
Zircon 91/4.50 49.50 384 4000
CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 200

All Aluminium Alloy Conductor


AAAC 1120 Aust. Standard - AS 1531

Strands/ Overall Nominated Nominated


Code Wire Diameter Minimum Mass
Name Diameter (approx) Breaking kg per km
mm mm Load kN

Chlorine 7/2.50 7.50 8.18 94.3


Chromium 7/2.75 8.25 9.91 113

Fluorine 7/3.00 9.00 11.8 135

Helium 7/3.75 11.25 17.6 211

Hydrogen 7/4.50 13.50 24.3 304

Iodine 7/4.75 14.25 27.1 339

Krypton 19/3.25 16.25 37.4 433

Lutetium 19/3.50 17.50 41.7 503

Neon 19/3.75 18.75 47.8 576

Nitrogen 37/3.00 21.00 62.2 721

Nobelium 37/3.25 22.75 72.8 845

Oxygen 19/4.75 23.75 73.6 924

Phosphorus 37/3.75 26.25 93.1 1120

Selenium 61/3.25 29.25 114 1400

Silicon 61/3.50 31.50 127 1620

Sulphur 61/3.75 33.75 145 1860


CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 201

Steel Conductor / Galvanised


SC/GZ Aust. Standard - AS 1222 Part 1

Strands/ Overall Nominated Nominated


Minimum Mass
Wire Diameter
kg per km
Diameter (approx) Breaking
Load
mm mm kN

3/2.00 4.31 11.70 74


3/2.75 5.93 22.20 140
7/2.00 6.00 26.00 173
7/2.75 8.25 49.00 328
7/3.25 9.75 68.70 458
19/2.00 10.00 70.50 473
7/3.75 11.25 91.30 609
19/2.75 13.75 133.00 894
19/3.25 16.25 186.00 1250
CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 202

Hard Drawn Copper Conductor


HDC Aust. Standard - AS 1746

Strands/ Overall Nominated Nominated


Minimum Mass
Wire Diameter
kg per km
Diameter (approx) Breaking
Load
mm mm kN

7/1.00 3.00 2.32 49.3


7/1.25 3.75 3.59 76.9
7/1.75 5.25 6.89 151
7/2.00 6.00 8.89 197
7/2.75 8.25 16.20 375
7/3.50 10.50 25.40 607
19/2.00 10.00 23.60 538
19/2.75 13.75 43.10 1020
19/3.00 15.00 50.80 1210
37/1.75 12.25 35.60 806
37/2.50 17.50 70.30 1640
37/2.75 19.25 83.90 1990
37/3.00 21.00 98.90 2370
61/2.75 24.75 138.00 3290
CONDUCTORS INFORMATION

INDEX ////
////
CATEGORY

PRODUCT
K
SECTION
PAGE 203

STANDARD CONDUCTORS
All Aluminium Conductor to BS125………………………………….………….….. Page 204
Aluminium Conductor (Galvanised) Steel Reinforced to BS215…….…….….. Page 205 - 206
All Aluminium Conductor NZ……………………………………………………. ….. Page 207
CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


PRODUCT
////
CATEGORY
K
SECTION
PAGE 204

All Aluminium Conductor

ASC to BS 125

Strands/ Overall Nominated Nominated Strands/ Overall Nominated Nominated


Code Wire Diameter Minimum Mass Wire Diameter Minimum Mass
Name Diameter (approx) Breaking kg per km Code Diameter (approx) Breaking kg per km
mm mm Load kN Name mm mm Load kN
Midge 7/2.06 6.18 3.99 64 Cricket 7/5.36 16.08 24.03 432
Gnat 7/2.21 6.63 4.81 73 Hornet 19/3.25 16.26 25.2 434
Aphis 3/3.35 7.2 4.37 73 Caterpillar 19/3.53 17.65 29.3 512
Mosquito 7/2.59 7.77 6.33 101 Chafer 19/3.78 18.92 32.4 587
Weevil 3/3.66 7.9 5.1 86 Spider 19/3.99 19.95 36.6 652
Ladybird 7/2.79 8.38 7.26 117 Cockroach 19/4.22 21.08 40.4 731
Ant 7/3.10 9.3 8.28 145 Butterfly 19/4.65 23.25 48.75 868
Fly 7/3.40 10.21 9.9 174 Moth 19/5.00 25 55.92 1027
Bluebottle 7/3.66 10.98 11.77 202 Drone 37/3.58 25.06 56.2 1029
Earwig 7/3.78 11.35 12.56 215 Centipede 37/3.78 26.46 62.05 1145
Grasshopper 7/3.91 11.73 13.3 230 Locust 19/5.36 26.8 63.9 1179
Clegg 7/4.17 12.51 14.9 262 Maybug 37/4.09 28.63 71.5 1342
Wasp 7/4.39 13.18 16.32 290 Scorpion 37/4.27 29.87 77.2 1460
Beetle 19/2.67 13.35 17.76 293 Cicada 37/4.65 32.55 90.45 1733
Bee 7/4.90 14.7 20.2 361 Tarantula 37/5.23 36.61 122.5 2191
CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


PRODUCT
////
CATEGORY
K
SECTION
PAGE 205

Aluminium Conductor (Galvanized) Steel Reinforced

ACSR to BS 215

Strands/ Overall Nominated Nominated Strands/ Overall Nominated Nominated


Code Wire Diameter Minimum Mass Code Wire Diameter Minimum Mass
Name Diameter (approx) Breaking kg per km Name Diameter (approx) Breaking kg per km
mm mm Load kN mm mm Load kN
Mole 6/1/1.50 4.5 4.18 43 Otter 6/1/4.22 12.66 28.8 339
Squirrel 6/1/2.11 6.33 7.55 85 Skunk 12/7/2.59 12.95 52.9 464
Gopher 6/1/2.36 7.09 9.61 106 Cat 6/1/4.50 13.5 32.65 386
Weasel 6/1/2.59 7.77 11.45 128 Horse 12/7/2.79 13.95 25.7 538
Fox 6/1/2.79 8.37 13.15 148 Hare 6/1/4.72 14.16 35.95 425
Ferret 6/1/3.00 8.99 15.2 172 Dog 6/4.72+7/1.57 14.17 32.7 394
Rabbit 6/1/3.35 10.05 18.35 214 Hyena 7/4.39+7/1.93 14.57 41.7 451
Mink 6/1/3.66 10.97 21.8 255 Cougar 18/1/3.05 15.25 30.4 419
Beaver 6/1/3.99 11.97 25.75 303 Leopard 6/5.28+7/1.75 15.81 40.75 492
Racoon 6/1/4.09 12.27 27.05 319 Coyote 26/2.54+7/1.91 15.88 46.35 521
CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 206

Aluminium Conductor (Galvanized) Steel Reinforced

ACSR to BS 215

Strands/ Overall Nominated Nominated Strands/ Overall Nominated Nominated


Code Wire Diameter Minimum Mass Code Wire Diameter Minimum Mass
Name Diameter (approx) Breaking kg per km Name Diameter (approx) Breaking kg per km
mm mm Load kN mm mm Load kN
Tiger 30/7/2.36 16.54 58 602 Goat 30/7/0.146 25.96 135.8 1489

Dingo 18/1/3.35 16.75 35.7 506 Antelope 54/7/2.97 26.73 118.5 1415

Caracal 18/1/3.61 18.05 41.8 587 Bison 54/7/3.00 27 120.9 1443

Wolf 30/7/2.59 18.14 69.2 726 Sheep 30/7/3.99 27.93 156.3 1722

Jaguar 18/1/3.86 19.3 46.55 671 Zebra 54/7/3.18 28.62 131.9 1621

Lynx 30/7/2.79 19.56 79.8 842 Deer 30/7/4.27 29.89 178.6 1973

Panther 30/7/3.00 20.98 92.25 974 Camel 54/7/3.35 30.15 145.9 1799

Lion 30/7/3.18 22.26 100.4 1094 Elk 30/7/4.50 31.5 198.3 2190

Bear 30/7/3.35 23.47 111.2 1214 Moose 54/7/3.53 31.77 161 1998

Batang 18/4.78+7/1.68 24.16 69.6 1015 Moa 76/3.72+7/2.89 38.4 180.6 2641
CONDUCTORS INFORMATION

CONDUCTORS INFORMATION ////


////
CATEGORY

PRODUCT
K
SECTION
PAGE 207

All Aluminium Conductor


AAC NZ

Strands/ Overall Nominated Strands/ Overall Nominated


Code Wire Diameter Minimum Code Wire Diameter Minimum
Name Diameter (approx) Breaking Name Diameter (approx) Breaking
Mm mm Load kN Mm mm Load kN
Namu 7/2.11 6.33 4.1 Cricket 7/5.30 16.10 24.1
Gnat 7/2.05 6.62 4.8 Hornet 19/3.25 16.25 25.0
Poko 7/2.36 7.08 5.1 Weta 19/3.35 16.75 26.2
Ladybird 7/2.80 8.40 7.2 Huhu 37/2.52 17.60 30.1
Kutu 7/3.00 9.00 7.9 Caterpillar 19/3.50 17.70 29.3
Fly 7/3.40 10.20 9.9 Chafer 19/3.78 18.90 32.4
Rango 7/3.66 10.98 11.7 Mata 19/3.86 19.30 33.8
Grasshopper 7/3.91 11.73 13.3 Spider 19/3.40 19.94 36.6
Moka 7/4.09 12.26 Cockroach 19/4.21 21.10 40.4
Wasp 7/4.40 13.20 16.0 Butterfly 19/4.64 23.25 48.8
Beetle 19/2.66 13.35 17.8 Centipede 37/3.78 26.46 62.1
Weke 7/4.72 14.16 18.5 Cicada 37/4.65 32.54 90.5
Bee 7/4.90 14.70 20.2
DESCRIPTION INDEX

DESCRIPTION INDEX ////


////
CATEGORY

PRODUCT
*
SECTION
PAGE 208

A C
Air break switch Page 143 Cable cutters Page 119
Aluminium deadends Page 59 Cable rollers Page 116 - 117
Cable stripper Page 113
Aluminium line guards Page 63
Canvas tool bag Page 112
Aluminium line splices Page 64 Cast bar spacer Page 28
Aluminium strain clamp Page 78 Cast iron strain clamp Page 79
Aluminium suspension clamp Page 72 & 73 Cast iron support clamp Page 77
Aluminium trunnion support clamp Page 74 Cast iron suspension clamp Page 76
Cat-1 Page 140
Anchor shackle Page 29
CCT conductor fittings Page 19
Armour rods – aluminium Page 61 Chain link Page 36
Armour rods – steel Page 62 Clamp top horizontal line post insulator Page 159
Automatic deadends Page 144 & 147 Clamp top vertical line post insulator Page 160
Automatic splices Page 145,146,148 Clevis thimble Page 44
Clevis tongue Page 32
B Clevis tongue twisted Page 33
Bail clamps Page 48 Closing tool Page 27
Ball & socket disc insulator Page 154 Combination hook Page 93
Ball & socket disc insulator Glass Page 166 Comealong clamps Page 114
Ball & socket disc insulators: Fog profile Page 156 Compositz distribution DS –M Series Page 180
Ball & socket disc insulators: Standard profile Page 154 Compression deadends Page 54 & 56
Ball & socket disc insulators: Desert Fog profile Page 157 Compression midspan Page 55 & 57
Ball & socket disc insulators: Glass Fog profile Page 167 Compression tools Page 120
Ball clevis Page 31 Conductor – high temperature Page 188 - 190
Ball eye extension link Page 35 Corona camera Page 132
Ball eye link Page 30 Cross arm brace Page 83
Ball hook Page 40 & 41
Bird diverters Page 70
DESCRIPTION INDEX

DESCRIPTION INDEX ////


////
CATEGORY

PRODUCT
*
SECTION
PAGE 209

D
Deadend – aluminium Page 59 G
Deadend – steel Page 60 Galvanized steel deadend Page 60
Double arming bolts Page 89 Galvanized steel splice Page 65
Dropout fuses Page 110 Glass disc insulator Page 166 - 168
Dropout fuse links Page 111 Gloves Page 112
Guy guard Page 68
Guy lock Page 67
E Guy thimble closed Page 90
Earth set Page 121 Guy thimble opened Page 90
Earth rod Page 122
Earth clamp Page 122 H
Emergency Tower Page 142 Heat shrink products Page 95 - 97
End caps Page 107
Helixon suspension clamp Page 75
Eye bolt Page 91
High temperature conductor Page 188 - 190
Eye nut Page 8
High voltage ABC products Page 13 - 18
Hook bolt Page 7
F Hook bracket Page 11
Fault indicators Page 134 - 139 Hook nut & Eye nut Page 8
Fibreglass Cabinets Commercial Page 101 Horizontal mounting line post insulator Page 159
Fibreglass Cabinets LV & HV Page 100 HVABC stringing equipment Page 18
Full tension line splice Page 66 I
Fuses Page 111 Insulator Pins Page 151
Fuse pin Page 93 Insulation piercing connector Page 9
G
Gain blocks Page 53 J
J Hook Page 93
DESCRIPTION INDEX

DESCRIPTION INDEX ////


////
CATEGORY

PRODUCT
*
SECTION
PAGE 210

K O
KU-Lugs Page 50
L P
L hook Page 93 Parallel groove clamps- Aluminium Page 45
LV ABC suspension clamp Page 4 Parallel groove clamps- Bi-metal Page 46
LV ABC tension clamp Page 6 Parallel groove clamps- Copper Page 47
LV ABC weak link Page 7 Pig hook Page 93
LV boots Page 104 - 106 Pig tail Page 93
Line pin & hooks Page 93 Pillar Base Residential Page 103
Line post bases Page 185 Pillars Underground Residential Page 102
Line post end fittings 1 Page 186
Line post end fittings 2 Page 187 Pin type aerodynamic profile insulator AS Page 162
Line post insulator Page 184 Pin type fog profile insulator AS Page 163
Linesmen equipment Page 112 - 121 Pin type standard profile insulator AS Page 161
Line stringing rollers Page 116 - 117 PLS – CADD Page 130 & 131
Line tap Page 51 Pole bucket Page 112
Link plates Page 88
Long rod suspension Page 182 & 183 Pole platform Page 113
Low voltage resin kits Page 98 & 99 Pole step Page 92
Low voltage switch Page 109 Pole strap Page 112
Lugall Page 115 Polly-mar shroud Page 141
Porcelain disc insulator ANSI Page 178
M Porcelain disc insulator AS Page 154 - 157
Maintenance tension link Page 87
Measuring meters Page 125 - 129 Porcelain disc insulator Desert AS Page 157
Modiewark Page 113 Porcelain disc insulator Fog AS Page 156
Q
N Quad spacer damper Page 25
DESCRIPTION INDEX

DESCRIPTION INDEX ////


////
CATEGORY

PRODUCT
*
SECTION
PAGE 211

R S
Ratchet spanner Page 113
Stay rod & bow Page 84
Resin kits Page 98 & 99
Steel guy lock Page 67
Steel line splices Page 65
S Strain insulator AS Page 165
Safety belts Page 112 Stringing rollers Page 116 & 117
Sagometer Page 133 Stripping tool Page 113
Sag links Page 85 Suspension Clamp & Extension Rollers Page 5
Scratch brush Page 113 Suspension clamp LVABC Page 4
Service fuse holder Page 111 Suspension clamp HVABC Page 17
Service puller Page 118 Suspension clamp Helixon Page 75
Service clamps Page 48 & 49 SupaRule Page 126 & 127
Shackle straps Page 81 & 82 Surge arrestors Page 123
Shrouds Page 108 & 141
Six bundle spacer damper Page 26
Socket clevis Page 37
Socket clevis extension link Page 34
Socket thimble Page 43
Socket tongue Page 38
Solid-Core station post insulator 4kN Page 172
Solid-Core station post insulator 6kN Page 171
Solid-Core station post insulator Multi Page 173
Spanner – LV ABC Page 113
Spiral vibration damper Page 69
Split bolts Page 51
Spool & shackle type insulator AS Page 164
Spool type insulator ANSI Page 178
DESCRIPTION INDEX

DESCRIPTION INDEX ////


////
CATEGORY

PRODUCT
*
SECTION
PAGE 212

T V
Telescopic hot sticks Page 118 Vertical mounting line post insulator Page 160
Tension clamp LVABC Page 6 Vibration damper type 4D Page 21
Tongue & clevis disc insulator ANSI Page 178 Vibration damper type Spiral Page 69
Tongue & clevis disc insulator Glass Page 168
Tongue & clevis disc insulator Porcelain Page 155
Tongue & clevis insulator IEC Page 175 & 176
W
Tongue hook Page 42 Warning markers Page 124
Tool Bag Page 112 Weak link Page 7
Transformer shrouds Page 108 Wedges Page 12
Triple spacer Page 24 Winch – Lugall Page 115
Twin spacer Page 22 & 28 Wire rope grips Page 52
Twin spacer damper Page 23
Twisted eye tongue Page 39
Twisted clevis tongue Page 33 X
Cross arm braces Page 83
U
"U" shackle straps Page 82 Y
Underground pillars and bases Page 102- 103 Yardage pro Page 128 & 129
Yoke - LVABC Page 10
Yoke – plate Page 86

Z
DULHUNTY POWER DISPLAY

DULHUNTY POWER DISPLAY ////


////
CATEGORY

PRODUCT
*
SECTION
PAGE 213
////
CATEGORY

//// SECTION
PRODUCT
CONTACTS

CONTACTS ////
////
CATEGORY

PRODUCT
*
SECTION

Dulhunty Power (Aust) Pty Ltd Dulhunty Power (Malaysia) Sdn. Bhd.
Unit 2/35 Waterloo Road, North Ryde Lot 8040, Jalan 2/D Kg. Baru Subang
Sydney NSW 2113, Australia 40150 Shah Alam
Telephone: + 61 2 9870 7277 Selangor Darul Ehsan, Malaysia
Facsimile: + 61 2 9870 7299 Telephone + 603 7843 0488
Email: sales@dulhunty.com Facsimile: + 603 7843 0433
Web: www.dulhuntypower.com Email: enquiry@dulhunty.com.my
Web: www.dulhuntypower.com
Dulhunty Power (N.Z.) Ltd
PO Box 281 Dulhunty Power (Thailand) Ltd
Whangaparaoa 3/2 Moo 7, Suwintawong Road
Auckland New Zealand Klongluangpang, AmphurMuang
Telephone + 64 9 424 7295 Chachoengsao 24000, Thailand
Facsimile: + 64 9 428 0577 Telephone + 66 3884 5675
Email: brian@dulhunty.co.nz Facsimile: + 66 3884 5674
Web: www.dulhuntypower.com Email: pana@dulhunty.co.th
Web: www.dulhuntypower.com
Dulhunty Power (H.K.) Ltd
2403 World Trade Centre
280 Gloucester Road
Causeway Bay, Hong Kong
Telephone: + 85 23187 8711
Facsimile: + 85 22577 5902
Email: sales@dulhuntychina.com
Web: www.dulhuntypower.com

Dulhunty Power (China) Ltd


3303#, Zhuan Qiao, Jiangdu
Jiangsu, 225233 P.R.C.
Telephone: + 86 514 6842 462
Facsimile: + 86 514 6842 463
Email: sales@dulhuntychina.com
Web: www.dulhuntypower.com