You are on page 1of 23
@ Nuovo Pignone INSTRUCTION MANUAL FOR FILTER HOUSE PULSE-JET GDX 2.2.14 GAS DETECTOR DET TRONICS POINTWATCH PIR9400 N. VER 01179/4 | To navigate through this document, click ‘on the “Bookmarks and Page” button + and use the bookmarks to access information, DET — TRONICS INSTRUCTIONS PointWatch™ Infrared Hydrocarbon Gas Detector PIR9400 Form 95-8440 Table of Contents APPLICATION... FEATURES. ‘SPECIFICATIONS. DESCRIPTION. Detection Method. Current Loop Output. Operating Modes INSTALLATION. Detector Location... to 100% LFL Linearized Output Options. Junction Boxes os General Wiring Requirement... Detector Wiring Procedure Detector Separation (Optional) ‘STARTUP PROCEDURE .. CALIBRATION oN Calibration Equipment = 10 Callraion Procedures eee TROUBLESHOOTING 18 MAINTENANCE. Disassembly and Cleaning Procedure... To Replace the IR Module... DEVICE REPAIR AND RETURN, 18 Office Locations, 18 ‘ORDERING INFORMATION. 19 PointWatch Detector. Junction Boxes .. Calibration Equipment... Spare Parts. ASSISTANCE APPENDIX... 20 Approval 20 ‘AttachrnentOptons 20 Caltration, Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figue 25 Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 List of Illustrations ‘410 20 ma Current Loop Resistance... PointWatch Wiring Requirements ‘Aluminum PointWatch Unit Dimensions in Inches (MM). ond Stainless Stee! PointWatch Unit Dimensions im inches (MtM).. “Junction Box Dimensions in Inches (MM) nn Tall PointWatch Junction Box with Window ‘Short PointWatch Junction Box PointWatch Gas Absorption Curves. ‘Aluminum PointWatch Disassembly. Stainless Steel PointWatch Disassembly IR Module and Base Assemblies. IR Module Removal... Gas Selection Switch Location a the Bottom of the Electronics Assembly Typical PointWatch Wiring, Standalone Configuration. ‘Typical PointWatch Wiring, PointWatch with Det-Tronics Junction Box... Junction Box Terminals and Calibration Switch ...9 ‘Typical PointWatch Wiring With Det-Tronies Infinit Transmiter 10 Typical PointWatch Wirirg with Eagle Communication Module set Options for Detector Separation une: 10 ‘Sensor Separation with Infiniti Transmitter and PointWatch.. 14 ‘Aluminum PointWatch Detector Cabration Por. 13 ‘Aluminum PointWatch Detector Calibration Configuration Sianiss Stoel PoitWatch Detector Clibaton Configuration ‘Aurrinum PointWatch Detector Disassombiy for Cleaning we Siainlss Stee PoinWatchDetecor Disassembly for Cleaning 43 List of Tables Curent Lop Oupu Levels and Conespondng Status indications... 2 Mounting Orientation 6 Instalaion Options for intusve and Non-intrusive Calibration. soe Calibrate or Check sand Calibration Sequence, Inhibited Current Output.12 Troubleshooting Table. 15

You might also like