WASH PIPE DATA SHEET ISO 9001:2000

BROUSSARD, LA HOUMA, LA HOUSTON, TX FM 65550


(337) 837-2345 (985) 851-0306 (281) 999-0047
CONNECTION MINIMUM MINIMUM MINIMUM
NOMINAL PIPE PIPE DIMENSIONS PIPE CRITICAL MINIMUM OPTIMUM MAXIMUM
THREAD DIMENSIONS DRIFT WALL YIELDING FAILING
SIZE WEIGHT GRADE SECTION MAKE-UP MAKE-UP MAKE-UP
DESCRIPTION OD ID OD ID THICKNESS TENSILE LOAD TENSILE LOAD
(in) (lb/ft) (in) (in) (in) (in) (in) (API) (sq in) (in) (lbf) (lbf) (ft lb) (ft lb) (ft lb)
3
/4 " 1.50 1-STEP FJ 1.050 0.742 1.050 0.742 0.648 N-80 0.165 0.123 13,183 16,479 175 197 219

1" HW 3.36 3/4"CS 1.315 0.687 1.315 0.687 0.593 P-110 0.487 0.251 53,569 60,874 300 400 400

1" 2.25 1-STEP FJ 1.315 0.957 1.315 0.957 0.863 P-110 0.314 0.143 34,537 39,246 250 281 313

1" 2.25 1-STEP FJ 1.315 0.957 1.315 0.957 0.863 S-135 0.314 0.143 42,386 45,526 250 281 313
1
1 /4 " 3.02 1-STEP FJ 1.660 1.278 1.660 1.278 1.184 P-110 0.449 0.153 49,341 56,069 400 450 500

1 1 /4 " 3.02 1-STEP FJ 1.660 1.278 1.660 1.278 1.184 S-135 0.449 0.153 60,555 65,040 400 450 500

1 1/4" HW 5.32 1" CS 1.660 0.875 1.660 0.875 0.848 S-135 0.700 0.314 94,444 101,440 400 450 500

1 1 /2 " 3.64 1-STEP FJ 1.900 1.500 1.900 1.500 1.406 P-110 0.548 0.160 60,311 68,535 400 450 500

1 1 /2 " 3.64 1-STEP FJ 1.900 1.500 1.900 1.500 1.406 S-135 0.548 0.160 74,018 79,500 400 450 500
1 1
1 /2" HW 5.53 1 /4" CS 1.900 1.241 1.900 1.300 1.147 S-135 0.844 0.264 113,939 122,379 600 675 750
13
1 /16" 7 28
7.28 W-FJ 1.813
813 0.750
750 1.813
813 0.750
750 0.656
656 P-110 0.937
937 0.425
425 103,079 117,135 800 900 1,000
000

2 1/16" 4.50 2-STEP FJ 2.063 1.613 2.063 1.613 1.519 P-110 0.572 0.180 62,969 71,555 450 506 563
3
2 /8 " 4.60 2-STEP FJ 2.375 1.995 2.375 1.995 1.901 P-110 0.610 0.152 67,105 76,256 600 675 750

2 3/8" HW 7.70 2 1/16" CS 2.375 1.700 2.375 1.700 1.606 P-110 0.884 0.270 97,193 110,447 900 1,013 1,125

2 7 /8 " 6.50 2-STEP FJ 2.875 2.441 2.875 2.441 2.347 P-105 0.876 0.174 91,979 105,119 800 900 1,000
7 3
2 /8" HW 11.60 2 /8" CS 2.875 1.945 2.875 1.945 1.901 N-80 1.344 0.372 107,525 134,406 1,500 1,688 1,875

3 1/4" HW 14.00 2 7/8" CS 3.250 2.371 3.250 2.371 2.347 P-110 1.786 0.352 196,499 223,294 2,100 2,363 2,625

3 1/4" HW 17.80 2 7/8" CS 3.250 1.995 3.250 2.370 1.901 P-110 2.248 0.502 247,248 280,964 2,100 2,363 2,625
1
3 /2 " 9.30 2-STEP FJ 3.500 2.992 3.500 2.992 2.867 P-110 1.290 0.203 141,854 161,198 1,500 1,688 1,875

4" 12.93 2-STEP FJ 4.000 3.340 4.000 3.340 3.215 P-110 1.961 0.264 215,762 245,184 2,100 2,363 2,625

REVIEWING PE: Stephen R. Callegari, P.E. DATE SIGNED: May 9, 2011

PE REGISTRATION: 17314 Mechanical Engineering 03-224 Rev 05-09-2011

STATE OF REGISTRATION: Louisiana SIGNATURE OF PE:

Tensile values given are for connections without any torque applied to the connection. The minimum cross sectional area under the last thread was used for the critical tensile area and tensile connection calculations.
Dimensions from drawings supplied by Concentric Pipe And Tool Rentals, L.L.C. were used in the calculations. Torque values listed have been provided by Concentric Pipe And Tool Rentals, L.L.C.

REVISION 05 PAGE 1 OF 1 05-09-2011


05-10-2011